key: cord-0821634-n3gukplu authors: Lin, Chengxiong; Wang, Yaocheng; Huang, Zhengyu; Guo, Yu; Wu, Wenming title: Low Cost Three-Dimensional Programmed Mini-Pump Used in PCR date: 2022-05-14 journal: Micromachines (Basel) DOI: 10.3390/mi13050772 sha: 6f0c97775b6f2dafe84c94d998685e932fdb5811 doc_id: 821634 cord_uid: n3gukplu Programmed mini-pumps play a significant role in various fields, such as chemistry, biology, and medicine, to transport a measured volume of liquid, especially in the current detection of COVID-19 with PCR. In view of the cost of the current automatic pipetting pump being higher, which is difficult to use in a regular lab, this paper designed and assembled a three-dimensional programmed mini-pump with the common parts and components, such as PLC controller, motor, microinjector, etc. With the weighting calibration before and after pipetting operation, the error of the pipette in 10 [Formula: see text] (0.2%), 2 [Formula: see text] (1.8%), and 1 [Formula: see text] (5.6%) can be obtained. Besides, the contrast test between three-dimensional programmed mini-pump and manual pipette was conducted with the ORF1ab and pGEM-3Zf (+) genes in qPCR. The results proved that the custom-made three-dimensional programmed mini-pump has a stronger reproducibility compared with manual pipette (ORF1ab: 24.06 ± 0.33 vs. 23.50 ± 0.58, p = 0.1014; pGEM-3Zf (+): 11.83.06 ± 0.24 vs. 11.50 ± 0.34, p = 0.8779). These results can lay the foundation for the functional, fast, and low-cost programmed mini-pump in PCR or other applications for trace measurements. The outbreak of coronavirus disease 2019 (COVID-19) has killed nearly 5 million people worldwide and infected more than 200 million since 2020, requiring thousands of people to undergo polymerase chain reaction (PCR) detection for the novel coronavirus every day, putting enormous pressure on the healthcare sector [1] . How to improve the efficiency and speed of PCR detection is of great significance for the timely feedback monitoring of the epidemic [2] . However, traditional PCR detection basically requires medical workers to manually complete reagent configuration, which has a series of disadvantages such as high human cost and being time-consuming. Although automated workstations can alleviate the above pressure to some extent, they cannot be widely promoted in remote and backward areas due to the high cost and other problems. Mini-pumps play a significant role in microfluidic transport, and thus, they are widely used in various fields such as chemistry, biology, and medicine to transport a measured volume of liquid, often as a media dispenser [3] . Mini-pumps come in several designs for various purposes with differing levels of accuracy and precision, from single piece glass pipettes to more complex adjustable or electronic pipettes. Many mini-pump types work by creating a partial vacuum above the liquid-holding chamber and selectively releasing this vacuum to draw up and dispense liquid (e.g., syringe pump [4, 5] , peristaltic pump [6, 7] , and piezoelectric mini-pump [8, 9] ). Although these pumps have prominent advantages, it is high-cost to integrate these pumps into laboratory use or relevant equipment, especially in their fully automatic form. Programmed mini-pumps are very important in the current rapid-development era, and can save much time during detection or operation, reduce the risk of repetitive strain error from humans, and ensure the reliability of pipetting results with high accuracy and can be used for special occasions, such as radioactive liquid, infectious fluid, or other environments not suitable for human operation [10] [11] [12] . As a result, with the huge demand of the detection market, more and more attention has been paid to highly automated pipetting systems. For example, as the important detection part of COVID-19, PCR test samples from detecting point need to be divided and mixed in the range of a few microliters to meet the PCR examination requirement [13] [14] [15] [16] . A conventional manual pipette is difficult to meet the sudden outbreak detection and the number of samples tested could reach millions in a medium or large city. On the other hand, it is important to ensure the accuracy on the basis of rapid suction and discharge, especially in small doses [17] [18] [19] . In view of the high cost of the current pipetting pump, our group independently designed and assembled a three-dimensional programmed mini-pump with the common parts and components, such as programmable logic controller (PLC) controller, motor, microinjector, etc. Through the accuracy test and case comparison in quantitative PCR (qPCR) with manual pipette, it can lay the foundation for the functional, fast, and low-cost programmed mini-pump in PCR or other applications for trace measurements. The custom-made three-dimensional programmed mini-pump was mainly made of PC desktop (Lenovo, Shenzhen, China), PLC controller (Shenzhen Bianneng technology, Shenzhen, China), motor actuator (CNYOHO, Wenzhou, China), motor (CNY-OHO, Wenzhou, China) for X/Y/Z axis and microinjector (Gaoge, Shanghai, China), and corresponding guide rail (Fanggong, Taizhou, China), as shown in Figure 1 . The movement in X/Y/Z direction of the equipment is mainly driven by the screw rod connected the motor and screw rod drive slider. The guide rail in different directions was mounted on the slider and the pipette was mounted on the slider in Z direction. As the core component, the slider near the microinjector was replaced with a baffle for advancing or withdrawing the end of the microinjector. In the current experiment, the measurement range of the microinjector was 10 µL. Before the experiments, program commands could be entered into the PLC controller from the PC desktop (there is a typical program command in the Appendix A as an example). The overall principle is that the suction or drainage of the microinjector occurred after the positions in three directions were determined. In order to verify the pipetting accuracy of the above custom-made three-di sional precision automatic pipette, the relative verification experiment was carrie according to the weighing method [20] . Through measuring the weight of numbered tainers before and after the experiment with a standard balance (precision 0.1 mg volume of the liquid can be obtained from the density (Figure 2 ). In the current ex ment, the liquid used for accuracy verification was deionized water (1 g/mL in 4 °C there were three volume standards (10 μL, 2 μL, 1 μL). For the manual pipetting ex ment of 10 μL, the total of liquid was 50 μL in a continuous pipette, namely 5 times the latter two was 20 μL (10 times for 2 μL and 20 times for 1 μL). All the accuracy fication experiments were repeated 10 times to avoid error. Besides, the comparison o was a commercially available equivalent system in order to reduce the cost. The re accuracy-defined formula is listed below: where and both mean the single operation. In order to verify the pipetting accuracy of the above custom-made three-dimensional precision automatic pipette, the relative verification experiment was carried out according to the weighing method [20] . Through measuring the weight of numbered containers before and after the experiment with a standard balance (precision 0.1 mg), the volume of the liquid can be obtained from the density ( Figure 2 ). In the current experiment, the liquid used for accuracy verification was deionized water (1 g/mL in 4 • C) and there were three volume standards (10 µL, 2 µL, 1 µL). For the manual pipetting experiment of 10 µL, the total of liquid was 50 µL in a continuous pipette, namely 5 times, and the latter two was 20 µL (10 times for 2 µL and 20 times for 1 µL). All the accuracy verification experiments were repeated 10 times to avoid error. Besides, the comparison object was a commercially available equivalent system in order to reduce the cost. The related accuracy-defined formula is listed below: where V measured and V designed both mean the single operation. In addition, to prove the three-dimensional precision automatic pipette which can used in laboratories, fluorescence experiments were conducted in a commercial real-tim qPCR (Connect, Bio Rad, Hercules, CA, USA) with a manual pipette (Pipet-Lite, Rain Oakland, CA, USA) as reference. By comparing the fluorescence intensity and the produ of the two devices, the performance of the microdevice could be verified. PCR Reage contained a buffer composed of 10 μL premix, 1 μL forward primer, 1 μL reverse prime 1 μL eva green, 1 μL DNA template, and 6 μL DI water. There were two primer sequenc were listed in Table 1 : pGEM The gene of ORF1ab and pGEM-3Zf (+) was inserted into pUC57 plasmid vector (Sa gon Biotech, Shanghai, China) by recombinase, which was further used as the PCR targ Fluorinated oil (HFE 7500, 3M Novec, San Diego,USA) was used as the oil phase, a agarose powder (V900510, Sigma-Aldrich, MO, USA) was used for agarose gel elect phoresis. Besides, the concentrations of the DNA template were changed (10 4 , 10 5 , 10 6 , copies/µL). Before the Eppendorf tubes were moved to the qPCR, centrifugal operati was conducted to mix up the above 6 liquids. The two-steps cyclic heating process In addition, to prove the three-dimensional precision automatic pipette which can be used in laboratories, fluorescence experiments were conducted in a commercial real-time qPCR (Connect, Bio Rad, Hercules, CA, USA) with a manual pipette (Pipet-Lite, Rainin, Oakland, CA, USA) as reference. By comparing the fluorescence intensity and the product of the two devices, the performance of the microdevice could be verified. PCR Reagents contained a buffer composed of 10 µL premix, 1 µL forward primer, 1 µL reverse primers, 1 µL eva green, 1 µL DNA template, and 6 µL DI water. There were two primer sequences were listed in Table 1 : The gene of ORF1ab and pGEM-3Zf (+) was inserted into pUC57 plasmid vector (Sangon Biotech, Shanghai, China) by recombinase, which was further used as the PCR target. Fluorinated oil (HFE 7500, 3M Novec, San Diego, CA, USA) was used as the oil phase, and agarose powder (V900510, Sigma-Aldrich, MO, USA) was used for agarose gel electrophoresis. Besides, the concentrations of the DNA template were changed (10 4 , 10 5 , 10 6 , 10 7 copies/µL). Before the Eppendorf tubes were moved to the qPCR, centrifugal operation was conducted to mix up the above 6 liquids. The two-steps cyclic heating process in qPCR was 95 • C for 15 s and 60 • C for 35 s. The heating cycle was 40 times. In the tests of accuracy verification, the experimental data were presented by the mean and standard deviation. F test (analysis of variance) was used to determine the significant difference among different esophageal samples under the same test conditions. The level of statistical significance was set to p < 0.05. According to the measuring principle in Section 2.2, the accuracy can be calculated as shown in Figure 3 . The average error volume of suction and discharge are 2.0 × 10 −5 L, 3.6 × 10 −5 L, and 5.6 × 10 −5 L, namely, the corresponding accuracies are 0.2% (10 µL), 1.8% (2 µL), and 5.6% (1 µL). It can be found that the pipetting accuracy increases with the increasing measuring volume for a single injector (p < 0.05). On the one hand, for an air displacement pump, the smaller the volume, the more difficult its precision control is. On the other hand, as the volume decreases, the emptying of the injection pump becomes more difficult due to surface tension of DI water. In a word, sealing is a guarantee of accuracy of the pump and the influence of surface tension aggravate when the volume reduces to a certain degree. As a contrast, current publications paid more attention to the liquid volume range around 10 µL for microfluidics, such as peristaltic pump [21] and pressure pump [22] . The current accuracy of commercial pipetting pumps at 1 µL, 10 µL are 5%, 1.5% respectively (https://craft-oem.s3.amazonaws.com/File-Uploads/695216-0 1_ZeusLT_SpecSheet_A4_EN_LR.PDF?v=1,557,757,671, accessed on 6 May 2022), such as ZEUS and ZEUS @ LT (Hamilton, Switzerland), S1 pipetting workstation (Superh2, Foshan, China). As a result, the custom-made three-dimensional programmed mini-pump has a comparable pipetting accuracy. Furthermore, the expense of the custom-made threedimensional programmed mini-pump, namely the assembly price, reduces to a large extent (250 US Dollar) under the condition of meeting basic pipetting accuracy, which was much less than the commercial equipment (4000 US Dollar for ZEUS or ZEUS @ LT). icromachines 2022, 13, x FOR PEER REVIEW significant difference among different esophageal samples under the same test condit The level of statistical significance was set to p < 0.05. According to the measuring principle in Section 2.2, the accuracy can be calcu as shown in Figure 3 . The average error volume of suction and discharge 2.0 10 L, 3.6 10 L, and 5.6 10 L, namely, the corresponding accuracie 0.2% (10 μL), 1.8% (2 μL), and 5.6% (1 μL). It can be found that the pipetting accu increases with the increasing measuring volume for a single injector (p < 0.05). On th hand, for an air displacement pump, the smaller the volume, the more difficult its p sion control is. On the other hand, as the volume decreases, the emptying of the inje pump becomes more difficult due to surface tension of DI water. In a word, sealing guarantee of accuracy of the pump and the influence of surface tension aggravate w the volume reduces to a certain degree. As a contrast, current publications paid mo tention to the liquid volume range around 10 μL for microfluidics, such as peris pump [21] and pressure pump [22] . The current accuracy of commercial pipetting pu at 1 μL, 10 μL are 5%, 1.5% respectively (https://craft-oem.s3.amazonaws.com/File loads/695216-01_ZeusLT_SpecSheet_A4_EN_LR.PDF?v=1,557,757,671), such as Z and ZEUS @ LT (Hamilton, Switzerland), S1 pipetting workstation (Superh2, Fo China). As a result, the custom-made three-dimensional programmed mini-pump comparable pipetting accuracy. Furthermore, the expense of the custom-made thre mensional programmed mini-pump, namely the assembly price, reduces to a large e (250 US Dollar) under the condition of meeting basic pipetting accuracy, which was m less than the commercial equipment (4000 US Dollar for ZEUS or ZEUS @ LT). As the typical detected gene in COVID-19, ORF1ab was selected as the feature in the current experiment [23, 24] . As shown in Figure 4a ,b, SV4, SV5, SV6, and SV7 r sent the different template DNA concentration (10 4 , 10 5 , 10 6 , 10 7 copies/μL, respectiv The 5 repetitions of samples with a template DNA concentration of 10 4 copies/µL tested for consistency and stability of PCR results, and the samples with gradually v concentration can verify the correctness of suction or drainage. The fluorescence inte of different reaction mixture increases gradually as the reaction proceeds. Compar the manual pipette, the relative fluorescence intensity of the custom-made three-di sional programmed mini-pump presents good coincidence performance at the tem As the typical detected gene in COVID-19, ORF1ab was selected as the feature gene in the current experiment [23, 24] . As shown in Figure 4a ,b, SV4, SV5, SV6, and SV7 represent the different template DNA concentration (10 4 , 10 5 , 10 6 , 10 7 copies/µL, respectively). The 5 repetitions of samples with a template DNA concentration of 10 4 copies/µL were tested for consistency and stability of PCR results, and the samples with gradually varied concentration can verify the correctness of suction or drainage. The fluorescence intensity of different reaction mixture increases gradually as the reaction proceeds. Compared to the manual pipette, the relative fluorescence intensity of the custom-made three-dimensional programmed mini-pump presents good coincidence performance at the template DNA concentration of copies/µL. Meanwhile, the differences are also obvious for different template DNA concentration. As can be seen from Figure 4c , the same template CT value has a stronger reproducibility for the custom-made three-dimensional programmed mini-pump compared with manual pipette (24.06 ± 0.33 vs. 23.50 ± 0.58, p = 0.1014), which shows a manual pipetting error for second sample with a concentration of 10 4 copies/µL. For current laboratory, manual pipettes are the main pipetting tools with a range of 1-1000 µL. As a result, the custom-made three-dimensional programmed mini-pump can become one of pipetting options in an automatic mode. Besides, the similar fluorescent results of pGEM-3Zf (+) were shown in Figure 4d -f, and the template CT value shows similarities for the custom-made three-dimensional programmed mini-pump and manual pipette (11.83 .06 ± 0.24 vs. 11.50 ± 0.34, p = 0.8779). icromachines 2022, 13, x FOR PEER REVIEW 6 of pump compared with manual pipette (24.06 ± 0.33 vs. 23.50 ± 0.58, p = 0.1014), which shows a manual pipetting error for second sample with a concentration of 10 4 copies/µL For current laboratory, manual pipettes are the main pipetting tools with a range of 1 1000 μL. As a result, the custom-made three-dimensional programmed mini-pump can become one of pipetting options in an automatic mode. Besides, the similar fluorescen results of pGEM-3Zf (+) were shown in Figure 4d -f, and the template CT value show similarities for the custom-made three-dimensional programmed mini-pump and manua pipette (11.83.06 ± 0.24 vs. 11.50 ± 0.34, p = 0.8779). As a pipetting system, this paper describes a custom-made three-dimensional pro grammed mini-pump consisting of common PC desktop, PLC controller, motor actuator motor for X\Y\Z axis, and pipettor and corresponding guide rail. Through a standard correction method for accuracy and PCR verification for application, the three-dimen sional precision automatic pipette was verified. The conclusions can be summarized in two main parts: As a pipetting system, this paper describes a custom-made three-dimensional programmed mini-pump consisting of common PC desktop, PLC controller, motor actuator, motor for X\Y\Z axis, and pipettor and corresponding guide rail. Through a standard correction method for accuracy and PCR verification for application, the three-dimensional precision automatic pipette was verified. The conclusions can be summarized in two main parts: The authors declare no conflict of interest. Note: @ can be used for an External adjustable window for different volume of pipetting and cycle index. Relative to manual pipette, three-dimensional programmed mini-pump has stronger reproducibility in PCR application custom-made three-dimensional programmed mini-pump was assembled with an accuracy of 0.2% for 10 µL, 1.8% for 2 µL, and 5.6% for 1 µL. 2. Relative to manual pipette, three-dimensional programmed mini-pump has a stronger reproducibility in PCR application The current programmed mini-pumpscan be realized with low cost Large-scale frequent testing and tracing to supplement control of Covid-19 and vaccination rollout constrained by supply Guidelines for validation of qualitative real-time pcr methods Passive Micropump for Highly Stable, Long-Termed, and Large Volume of Droplet Generation/Transport Inside 3D Microchannels Capable of Surfactant-Free and Droplet-Based Thermocycled Reverse Transcription-Polymerase Chain Reactions Based on a Single Thermost Controlling the morphology of rhodium nanocrystals by manipulating the growth kinetics with a syringe pump Open-Source Syringe Pump Library Adaptive Repetitive Control of Peristaltic Pump Flow Rate with an Optical Flow Sensing System Adoption of reinforcement learning for the intelligent control of a microfluidic peristaltic pump A Fluid-Structure Interaction Based Simulation Study Of Piezoelectric Micropump For Drug Delivery Application Advances in passive check valve piezoelectric pumps A semi-automatic, non-radioactive 384-well high throughput screening DIO2 assay Improved semi automatic approach to count the tracks on LR-115 film for monitoring of radioactive elements Automatic electronic laboratory-based reporting of notifiable infectious diseases at a large health system Sensitive detection and quantification of SARS-CoV-2 by multiplex droplet digital RT-PCR Highly accurate and sensitive diagnostic detection of SARS-CoV-2 by digital PCR-ScienceDirect Comparison of Three Sample-to-Answer RT-PCR Testing Platforms for the Detection of SARS-CoV-2 RNA in Positive Nasopharyngeal and Nasal Swabs RT-PCR diagnosis of COVID-19 from exhaled breath condensate: A clinical study Drug delivery applications of mechanical micropumps A Highly Programmable Magnetic Micropump A Peristaltic Micropump Based on the Fast Electrochemical Actuator: Design, Fabrication, and Preliminary Testing Hydrocarbon and Lipid Microbiology Protocols Springer Protocols Handbooks Open-source, 3D-printed Peristaltic Pumps for Small Volume Point-of-Care Liquid Handling µPump: An Open-Source Pressure Pump for Precision Fluid Handling in Microfluidics Laboratory Diagnosis of Coronavirus Disease-2019 (COVID-19) Potential preanalytical and analytical vulnerabilities in the laboratory diagnosis of coronavirus disease 2019 (COVID-19)