key: cord-0819551-5svugo75 authors: Vasbinder, Alexi; Raffield, Laura Marie; Gao, Yan; Engstrom, Gunnar; Quyyumi, Arshed Ali; Reiner, Alexander Paul; Reiser, Jochen; Hayek, Salim Salim title: Assay-related differences in SuPAR levels: implications for measurement and data interpretation date: 2022-05-14 journal: J Nephrol DOI: 10.1007/s40620-022-01344-7 sha: 029db3e162944fec47796882c64c7f005e51f0d2 doc_id: 819551 cord_uid: 5svugo75 nan was measured using two different approaches, and examined the correlation between assays, the association between levels and clinical characteristics, and their risk discrimination ability for relevant outcomes. Data on plasma suPAR measurement, clinical characteristics and outcomes were obtained from the following cohorts: a subset (n = 4637) of the Malmö Diet and Cancer Study (MDCS)which is a Swedish population-based cohort in which suPAR was measured using the suPARnostic ELISA and Olink CVD-I panel; a subset (n = 1492) of the Jackson Heart Study (JHS) which recruited African American participants from Jackson, Mississippi in whom suPAR was measured using the Human uPAR Quantikine ELISA and SOMAscan; and lastly, a subset (n = 487) of the Emory Cardiovascular Biobank (EmCAB) which enrolled patients undergoing coronary catheterization, in whom suPAR was measured with the suPARnostic and Human uPAR Quantikine ELISAs [1] . Data transformation and normalization procedures were performed for the SOMAscan and Olink assays according to standard protocols developed by the manufacturers as part of the data processing in the original assays. The procedures are necessary to account for intra-and inter-assay variation and for the interpretation of raw data. In JHS, SOMAscan values were natural log-transformed, standardized to a mean of 0 and an SD of 1 within each of three batches, and then inverse-normalized across batches. In MDCS, Olink's normalized protein expression units were log-based 2 transformed. We used Spearman-Rank to report the pair-wise correlation between assays. We report standardized estimates for the association between clinical characteristics and suPAR measures derived using linear regression, with the suPAR level as the dependent variable and clinical characteristics as independent covariates. Lastly, we computed Harrell's C-statistic as a measure of risk discrimination for * Salim Salim Hayek shayek@med.umich.edu each suPAR assay for the following outcomes: all-cause mortality, cardiovascular mortality, and incident chronic kidney disease (defined as a decrease in creatinine-derived eGFR to below 60 ml/min/1.73 m 2 ). Analyses were performed using SPSS 24 (IBM, NY, USA) and R (R Core Team, 2014). We found extensive variation in the correlation between suPAR assays ( Table 1 ). The correlation between the proteomics platforms and ELISAs were modest at best, with a correlation of 0.285 between the Human uPAR Quantikine and SOMAScan, and 0.586 between the suPARnostic and Olink. The correlation between immunoassays (suPARnostic and Human uPAR Quantikine) was relatively better at 0.753, with values obtained using the suPARnostic assay on average 50% higher than the Quantikine-derived values, albeit with significant variability given a standard deviation of 50%. Associations with relevant clinical characteristics and their directionality were mostly consistent across measures, except for the lack of an association between SOMAScanderived suPAR levels and diabetes mellitus (Table 1) . Risk discrimination as quantified using Harrell's C-statistic for all-cause death, cardiovascular death and incident chronic kidney disease differed between suPAR assays, with the most notable differences between the SOMAScan and Quantikine measures (Table 1) . This study highlights major discrepancies between suPAR measurements across commonly used assays, with modest correlations and differences in associations with outcomes. These findings warrant caution in deriving conclusions related to suPAR measures, notably when comparing results from different assays. Proteomics platforms, while useful for discovery, have limitations including cross-reactivity, lack of specificity, protein complexes and single nucleotide polymorphisms altering aptamer/antibody affinities, amongst others which may be more relevant for some assayed proteins such as suPAR [3] . The correlation in suPAR levels measured with SOMAScan and Olink has been previously reported to be modest (r = 0.48) [2] . Most importantly, proteomics-derived suPAR measures have not been previously cross-validated with ELISAs. We also found Table 1 Correlation, associations with clinical characteristics, and C-statistics stratified by cohort and assay Chronic kidney disease is defined as a decrease in eGFR to below 60 ml/min/1.73 m 2 at follow-up. Harrell's C-statistic is derived from time to event models which include only suPAR levels differences between the ELISA measurements, consistent with a prior report by Winnicki et al. in which suPAR levels using the suPARnostic assay were higher and outperformed the Human Quantikine uPAR ELISA in differentiating between patients with and without focal segmental glomerulosclerosis [4] . SuPAR exists in circulation in different forms originating from splice variants and proteolytic processing with varying levels of glycosylation and distinct biological activity. The suPARnostic ELISA consists of two monoclonal capture antibodies: one targeting the D III subunit, and the other the D II subunit, thus capturing full-length suPAR (D I D II D II ) and the D II D III fragment, but not D I . The Human uPAR Quantikine assay uses a monoclonal capture antibody and polyclonal detection antibodies. The specific suPAR forms detected by the various proteomics platforms are unknown. The discrepancy between assays may relate to their differing ability in detecting the various suPAR forms, with the suPARnostic assay's ability to detect both full length and cleaved suPAR forms explaining the higher levels reported and overall better risk discrimination. As suPAR is increasingly measured in clinical settings, understanding the differences in the methods of suPAR measurements is crucial for interpreting findings. Soluble urokinase receptor and chronic kidney disease Comparison of proteomic assessment methods in multiple cohort studies In aptamers they trust: the caveats of the SOMAscan biomarker discovery platform from SomaLogic Diagnostic and prognostic value of soluble urokinase-type plasminogen activator receptor (suPAR) in Focal segmental glomerulosclerosis and impact of detection method Variability in CKD biomarker studies: suPAR and kidney disease progression in the chronic kidney disease in children (CKiD) study Acknowledgements The Jackson Heart Study (JHS) is supported and conducted in collaboration with Jackson State University (HHSN268201800013I), Tougaloo College (HHSN268201800014I), the Mississippi State Department of Health (HHSN268201800015I) and the University of Mississippi Medical Center (HHSN268201800010I, HHSN268201800011I and HHSN268201800012I) contracts from the National Heart, Lung, and Blood Institute (NHLBI) and the National Institute on Minority Health and Health Disparities (NIMHD). The authors also wish to thank the staff and participants of the JHS. The views expressed in this manuscript are those of the authors and do not necessarily represent the views of the National Heart, Lung, and Blood Institute; the National Institutes of Health; or the U.S. Department of Health and Human Services. Funding Salim S. Hayek is supported by 1R01HL153384, U01-DK119083, R01-DK109720 and the Frankel Cardiovascular Center COVID-19: Impact Research Ignitor (U-M G024231) award. The project described was supported by the National Center for Advancing Translational Sciences, National Institutes of Health, through Grant KL2TR002490 with principal investigator Laura M. Raffield. Laura M. Raffield was also supported by T32HL129982 and R01HL132947. Alexi Vasbinder is supported by T32-HL007853. Alexander P. Reiner is supported by R01HL132947.