key: cord-0819080-hmdch1ds authors: Kim, Kwan Woo; Choi, Sungmi; Shin, Su-Kyoung; Lee, Imchang; Ku, Keun Bon; Kim, Seong Jun; Kim, Seil; Yi, Hana title: A Half-Day Genome Sequencing Protocol for Middle East Respiratory Syndrome Coronavirus date: 2021-02-19 journal: Front Microbiol DOI: 10.3389/fmicb.2021.602754 sha: 6034ddcbb6435de99da458c3e4f14ac518f1c8ff doc_id: 819080 cord_uid: hmdch1ds Recent coronavirus (CoV) outbreaks, including that of Middle East respiratory syndrome (MERS), have presented a threat to public health worldwide. A primary concern in these outbreaks is the extent of mutations in the CoV, and the content of viral variation that can be determined only by whole genome sequencing (WGS). We aimed to develop a time efficient WGS protocol, using universal primers spanning the entire MERS-CoV genome. MERS and synthetic Neoromicia capensis bat CoV genomes were successfully amplified using our developed PCR primer set and sequenced with MinION. All experimental and analytical processes took 6 h to complete and were also applied to synthetic animal serum samples, wherein the MERS-CoV genome sequence was completely recovered. Results showed that the complete genome of MERS-CoV and related variants could be directly obtained from clinical samples within half a day. Consequently, this method will contribute to rapid MERS diagnosis, particularly in future CoV epidemics. Recent consecutive outbreaks of Betacoronavirus, including the severe acute respiratory syndrome (SARS), Middle East respiratory syndrome (MERS), and coronavirus disease , have severely impacted the human population. To date, seven types of coronaviruses (CoVs) have caused epidemics in the world, of which four are mild types (229E, NL63, OC43, and HKU1), while three are severe types (SARS-CoV-1, SARS-CoV-2, and MERS-CoV). Among them, MERS-CoV first appeared in Saudi Arabia in 2012 following zoonotic transmission from camels to humans and subsequently spread to 27 countries across all continents, resulting in 2494 laboratory-confirmed cases of infections with a case-fatality rate of 34.4% (May 2020, WHO) (World Health Organization ([WHO] , 2019). For MERS-CoV diagnosis, WHO currently recommends real-time reverse transcription polymerase chain reaction (rRT-PCR) targeting the following three genes: upstream of the E protein gene (upE) , open reading frame 1b (ORF 1b) , and open reading frame 1a (ORF 1a). The nucleocapsid (N) protein gene can be further analyzed to enhance the sensitivity. The rRT-PCR method is highly sensitive for detecting known MERS-CoV, but it cannot determine the extent of genomic mutations. Therefore, for variant detection, WHO recommends phylogenetic analyses using a complete genome sequence (World Health Organization [WHO] , 2018). The whole genome sequencing (WGS) method is not only beneficial for mutant detection but also for tracing the origin of the virus and route of transmission, consequently establishing prevention strategies (Gilchrist et al., 2015) . Since the amount of viral nucleic acid in clinical samples is insufficient for direct genome sequencing, a precedent nucleic acid amplification step is required. However, constructing universal primers that effectively span the entire genome is difficult because viral genomes within the same species can greatly vary with a high mutation rate. Therefore, strainspecific primers have been designed for each viral strain, with the expenditure of time and effort. However, recently, universal primer sets have been successfully developed by a few leading research groups. For example, the conserved primer sets for each protein region of influenza virus have been developed for quick genome sequencing (Wang et al., 2015) . Additionally, universal primer sets have been developed for the HIV-1 genome to locate the mutation sites that are responsible for drug resistance (Gall et al., 2012) . These reports encouraged us to develop universal primers for MERS-CoV in the present study. To date, various methods have been used to amplify the MERS-CoV genome Moreno et al., 2017; Yusof et al., 2017) ; however, universal primers appropriate for lineage C of Betacoronavirus, which MERS-CoV belongs to, are yet to be developed. Despite the usefulness of the full-length genome, a major disadvantage is that genome amplification and sequencing is time consuming. It has therefore been impossible for the WGS method to primarily be used as an on-site diagnostic method. To significantly reduce the testing time, universal primers for MERS-CoV lineage C are needed, in addition to the establishment of a more efficient sequencing protocol. Accordingly, in the present study, we developed a WGS protocol that sequences the viral genome within half a day. The patient-derived MERS-CoV strain KNIH/002_05_2015 was obtained from Korea National Institute of Health (KNIH) and inoculated into cultured Vero E6 cells. The virus cultivation and RNA extraction were performed in a biosafety level-3 (BSL-3) laboratory at the Korea Research Institute of Chemical Technology (KRICT), as previously described. To evaluate the universality of the developed primers, Coronavirus Neoromicia/PML-PHE1/RSA/2011 (NCBI accession no. KC869678) was chosen as an experimental strain because it belongs to the same family as MERS-CoV (Hashemi-Shahraki et al., 2013) . Eleven genomic fragments of 2940 bp were synthesized using a commercial service (GENEWIZ Inc.). Thereafter, to allow the designed forward and reverse primer pair to localize in a single genomic segmental DNA, each two-consecutive-genomefragment was ligated into a 6 kb long fragment extension as described previously (Messing and Vieira, 1982) . The resulting 14 extended fragments were used as the template for PCR amplification. The genome sequences of MERS-CoV and related viruses were derived from Virus Pathogen Resources (ViPR) (Pickett et al., 2012) . The derived genome sequences were aligned using ViPR sequence alignment function. Following the alignment, conserved regions were selected and the candidate primers were chosen based on the following criteria: amplicon length, 2.5-3 kb; primer length, 18-23 nt; Tm, 53-57 • C; overlaps between amplicons >100 bp; number of degenerate bases <2; and number of inosine molecules <1. For the synthesis of first strand cDNA, Superscript III First-Strand Synthesis SuperMix (Cat No. 18080-400, Invitrogen) was used. The initial master mix contained 1 µl RNA (50 ng/µl or 10 ng/µl), 1 µl random hexamers (5 -NNNNNN-3 , 50 ng/µl), 1 µl annealing buffer, and 5 µl RNase/DNase-free water. The mixture was incubated at 65 • C for 5 min, and thereafter kept on ice for 1 min. Following the reaction, 10 µl 2× First-Strand Reaction Mix and 2 µl SuperScript III/RNaseOUT Enzyme Mix were added to the master mix and further incubated at 25 • C for 10 min, 55 • C for 90 min, and 85 • C for 5 min. The following reagents were used for PCR amplification: 2 µl cDNA, 1 µl forward primer (10 pmol/µl), 1 µl reverse primer (10 pmol/µl), 10 µl KAPA HotStart ReadyMix (Roche), and 6 µl distilled water. The mixture was initially heated at 98 • C for 30 s, and next, the mixture was subjected to a cycle comprising denaturation (at 98 • C for 5 s), annealing (at 55 • C for 30 s), and extension (at 72 • C for 2 min), which was repeated 30 times, and finally further elongation at 72 • C for 2 min. The PCR product was then purified using QIAquick R PCR Purification Kit (Qiagen). The purified amplicons were quantified and pooled into a single mixture to construct sequencing libraries. Purified amplicon mixture was sequenced using MinION (Oxford Nanopore), MiSeq (Illumina), and RS II (PacBio) according to the manufacturers' instructions. The amount of input DNA for sequencing library construction was 1.0-1.5 µg, 130 ng, and 10 µg for each method, respectively. The MinION sequencing library was constructed with Ligation Sequencing Kit (Oxford Nanopore) and then 1D sequencing was performed using R9.4 flow cells (Oxford Nanopore). A laptop with i7 CPU, 8 Gb RAM, and 128 GB solid state hard disk was used for MinION sequencing and base calling. The quality control and raw data processing were done using EPI2ME program (Oxford Nanopore). Base calling was performed with Q-score 7 using Guppy ver.3.4.4+a296acb (Oxford Nanopore). The MiSeq sequencing library was constructed with Nextera XT DNA Library Preparation Kit (Illumina) and sequenced with the 300 bp paired-end protocol. The MinION and MiSeq data were assembled using CLC Genomic Workbench 9.3.5 (Qiagen). The PacBio 10 kb sequencing library was constructed with SMRTbell Template Prep Kit 2.0 (PacBio) and sequenced with RS II. The raw data were filtered and aligned using SMRT Analysis program (PacBio) with Long Amplicon Analysis (LAA) option. The resulting long contigs were further manually cured using CodonCode aligner 8.0.2 (CodonCode Corporation). The phylogenetic trees were constructed using the consensus sequence with MEGA program (Kumar et al., 2016) . To evaluate the clinical applicability of the developed method, the synthetic clinical sample was prepared by diluting the cultured viral particles present in mouse serum. Serum of a 16-week old female mouse was extracted and the experimental procedure was approved by KRICT (IACUC 2018-8A-09-01). Dilution series of the serum with three different viral concentrations (4.4 × 10 5 , 4.4 × 10 4 , and 4.4 × 10 3 pfu/140 µl) were prepared. RNA was extracted from 140 µl of serum using the QIAamp viral RNA extraction Kit (Qiagen, Hilden, Germany) and eluted in 60 µl of elution buffer. Thus, the viral concentration in the extracted RNA was equivalent to 7.3 × 10 3 , 7.3 × 10 2 , and 7.3 × 10 1 pfu/µl. Based on the alignment results of the MERS-CoV-related genome, 68 primer candidates were obtained and subjected to experimental screening through reverse transcription and PCR. Consequently, 14 primer pairs that spanned the entire genome of MERS-CoV were obtained and named as the MP primer set ( Figure 1A and Table 1 ). When we checked the primer specificity against the NCBI database using basic local alignment search tool (BLAST), the primers did not bind to any viruses other than MERS-CoV. The complete genome sequences of HCoV-OC43 (NC_006213), HCoV-HKU1 (NC_006577), SARS-CoV-1 (NC_004718), SARS-CoV-2 (NC_045512), HCoV-229E (NC_002645), and HCoV-NL63 (NC_005831) were downloaded and further evaluated in silico to confirm the specificity of the 14 primer pairs. The results demonstrated the Betacoronavirus lineage C specificity of the chosen primers. In addition, the primers did not bind to other locations in the genome, except the ones we identified in the current study. All the 14 primer pairs included in MP primer set exhibited target site specificity by forming a single band amplicon having the expected size (3 kb) ( Figure 1B) . We synthesized cDNA using reverse-transcription to amplify the single-strand RNA CoV genome. To optimize cDNA priming method, the following two experimental methods were performed and evaluated. Method-A, which is adopted in this study, used a combination of a random hexamer (for RT) plus MP primers (for PCR). Method-B used MP primers both for RT as well as PCR (data not shown). When comparing the two methods, method-B showed a better detection limit for cDNA synthesis compared to method-A. However, in terms of specificity, method-A exhibited better amplicon quality with a single-band in gel electrophoresis, while method-B produced multi-bands in almost all primer pairs. Since a gel-elution step was required for such multiband amplicons and it caused DNA loss and resulted in an unmet amount of DNA required for sequencing platforms, we decided to choose random hexamer priming for the reversetranscription step. In addition, we tried multiplex PCR to save on handling time and cost. The first trial used one reaction tube with whole 14 primer pairs, and the second trial used two tubes each containing odd-numbered or even-numbered primer pairs. The amplification resulted in multiple bands with unexpected sizes, but the PCR products were purified and processed to PacBio RS II sequencing. Due to the high amplification bias and unwanted amplicons, we failed to obtain a complete genome sequence from any of the multiplex PCR products. Thus, we did not consider multiplex PCR as the amplification method. To determine the detection limit of the experiments, RNA concentrations of 1, 10, and 50 ng/µl were prepared and used for template RNA for cDNA synthesis. Once the PCR reaction was completed, the 10 and 50 ng/µl samples showed detectable bands in gel electrophoresis, but the 1 ng/µl sample did not. Thus, the minimum concentration and amount of template RNA required for cDNA synthesis was determined to be 10 ng/µl and 10 ng, respectively. To determine the optimal sequencing method, various sequencing techniques were evaluated. A consensus sequence of MERS-CoV strain KNIH/002_05_2015 was determined using the most frequent nucleotide found at each position in a sequence alignment of the three complete genome sequences derived from MinION, MiSeq, and RS II. The resultant single consensus sequence was deposited in GenBank (accession number MT387202). The consensus was used as a control sequence for comparison of the three genome sequence results from three different sequencing techniques. The MinION, MiSeq, and RS II sequences covered 99.81-99.91% regions of the entire MERS-CoV genome with a sequencing accuracy of 99.98-100%, confirming that applying any of these methods would yield a sequence that covers the entire genome using the MP primers ( Table 2) . With regard to the sequencer running time, MinION was the most time efficient technique, requiring only 5-30 min of sequencer running time and 30 min of assembly time. The 15-min MinION sequencing resulted in 0.5 Gb of raw data with 740.97× sequencing depth. Following sequence assembly, one long contig of full-length genome was obtained. This 15-min MinION assembled contig predominantly matched the consensus sequence, where only 17 out of 30108 bp were different, confirming the 99.9435% accuracy rate (Supplementary Figure 1) . Among the 17 different nucleotide sequences, 13 were originated from homopolymeric errors (Rang et al., 2018) and four were from sequencing technical errors. When MP primers were applied to the NeoCoV gene fragment extension (6 kb) template, all amplifications proved to be successful ( Figure 1C ). This proved that MP primers can be applied to a neighboring clade with a genome sequence similarity as low as 85%, confirming the universality of these primers. Although several primer pairs (MP7, 7 , 9, 11, and 12) presented multi-bands in NeoCoV amplification unlike in MERS-CoV, the sequencing was successfully performed without any gel-elution step. The amplicon mixture of NeoCoV synthetic genomic DNA was sequenced by MinION and a single contig of the complete genome sequence was recovered. The result demonstrated the universality of the MP primer and the optimized experimental and analytical procedures developed in the present study. When synthetic animal serum was evaluated, target amplicons were produced even at the lowest viral concentration (7.3 × 10 1 pfu/µl). The amplicon mixtures from the lowest viral concentration were successfully sequenced using MinION and assembled into a complete genome sequence with an accuracy >99.00%. Considering the amount of input RNA (1 µl) required for reverse transcription reaction, having more than 73 *Genome coverage means the percentage area coverage of a reference (consensus sequence, 30,108 bp) by the assembled contig. # Accuracy means the proportion of matched nucleotides in the assembled contig compared to a reference (consensus sequence, 30,108 bp). viral particles would facilitate application of the experimental protocol developed in this study. We therefore decided to use 10 2 viral particles per reaction as the detection limit of this newly developed method. To infer the universality of MP primers in silico, phylogenetic analysis was performed using all the known species of Betacoronavirus clade C. Maximum likelihood tree analysis of spike protein subunit1 (S1) amino acid sequence showed that MERS-CoV and NeoCoV had the farthest evolutionary distance among the six known species within the Betacoronavirus clade C (Figure 2) . Therefore, according to the evolutionary trend of S1 proteins, the two species analyzed in this study (MERS-CoV and NeoCoV) widely cover the diversity of members belonging to the Betacoronavirus clade C. However, based on spike protein subunit2 (S2) proteins, NeoCoV was recovered as a sister group of MERS-CoV, unlike the S1 tree (Supplementary Figure 2) . The designed MP primer set that spanned the entire genome of MERS-CoV was also successfully applied to NeoCoV, thus verifying its universality within the Betacoronavirus clade C. Despite the large genome sequence difference (89.6%) between the two viral species, MP primers worked well for WGS of both, indicating that the primers can universally be applied to clade C of Betacoronavirus. In addition, the MP primer set was able to amplify and recover the MERS-CoV genome contained in animal serum, suggesting that the developed experimental procedure can also be applied to clinical samples. Another major advantage of this MP primer set was that it covered nearly the complete genome sequence of the tested CoVs, despite their large genome size (30 kb). Amplification bias was found among target locations within the genome (Figure 3) . The primer number 02 was the most efficient region and number 12 was the least. Overall, the amplification efficiency was higher in the anterior part of the genome compared to the posterior region, potentially due to RNA degradation. RNA degrades for numerous reasons, but it mostly occurs from the 3 -end, a protein coding region where messenger RNA is present (Van Hoof and Parker, 2002) . This affected the 21-30 kb region, where the main protein coding genes of MERS-CoV are located, and this could have resulted in the differences observed in reverse-transcription efficiency. Secondly, the efficiency of transcription and amplification of a specific region in the gene was significantly reduced due to yet unknown reasons. The forward primer of MP7 is located in the RdRp gene, and the reverse primer is in the ORF 1b gene. Previously, WHO reported that the PCR efficiency of the RdRp and OFR 1b regions are lower than that of other regions; this was consistent with the fact that the amplification efficiency of MP7 was low in our experiment. Similarly, nucleic acid amplification test applied to hCoV-EMC reported that the sensitivity for the ORF 1b assay was lower than that for upE (Corman et al., 2012a) . Additionally, other studies demonstrated that the sensitivity of RdRp was lower than that of N (Corman et al., 2012b) , and ORF 1a was shown to have the highest sensitivity among all the assays (Corman et al., 2012a,b) . SARS-CoV-2, which is currently causing a pandemic, has also been reported to have higher amplification efficiency in ORF 1a than in ORF 1b (Jung et al., 2020) . Based on the previous reports, we decided that the MP7 region was difficult to cover with a single primer, and thus, we added a supplementary primer named MP7 to enhance the universality of that specific region. Real-time reverse transcription polymerase chain reaction is a useful method in terms of response-time (<2 h) and sensitivity, but sequence variations are not easily detected because the assay targets a very short sequence (100 bp). In reality, the regions where mutations of MERS-CoV frequently occur are spike glycoprotein and S1 (Anthony et al., 2017) , but the rRT-PCR cannot provide any information for variant detection. WGS is an irreplaceable method to obtain precise information on viral mutation, but we have to overcome the lengthier sequencing time and accuracy issues. Recently, the MinION-based rapid genome sequencing directly from clinical samples was reported for Ebola (Quick et al., 2016) and Zika (Quick et al., 2017) viruses. Based on their success, we further optimized the MinION process to suit MERS-CoV. Consequently, the sequencing and analysis of the entire MERS-CoV genome were completed in 1 h with a sequencing accuracy of 99.9435%. The consensus sequence determined in this study (MT387202) showed 8 nt variation compared to the reference genome sequence of patient-derived MERS-CoV strain FIGURE 2 | Maximum-likelihood tree based on spike protein subunit1 (S1) amino acid sequences. The farthest evolutionary distance between MERS-CoV and NeoCoV within the Betacoronavirus clade C demonstrates the universality of the MP primer set. KNIH/002_05_2015 (KT029139). The variation was observed on orf1a, orf1b, orf4a, orf4b, and spike glycoprotein. Those level of SNPs could be cell-culture adaptive mutations, which are frequently observed when putting patient-originated viruses in to culturing conditions for a long time (Dargan et al., 2010; Oka et al., 2014) . According to the phylogenetic trees inferred using the S1 and S2 domain of spike protein independently, a faster evolution rate was observed in S1 than S2 in the test strain in accordance with other corona viruses (Anthony et al., 2017; Sohrab and Azhar, 2020) . We wanted to verify the applicability of the developed protocol to clinical samples, but we could not recruit any patients since the MERS-CoV epidemic has already passed. To overcome the lack of clinical samples, synthetic animal serum samples were used instead. As previously reported elsewhere, MERS-CoV and SARS-CoV-2 were detected in patient serum samples using nucleic acid amplification methods (Oh et al., 2016; Zheng et al., 2020) . Thus, we chose serum as the diluent of viral particles. Considering that the viral load in MERS patients is 103-109 copy/ml (Oh et al., 2016) , because the detection limit in animal serum samples was 100 viral particles per reaction, the newly developed method seems to also be suitable for clinical samples. Given the practical working time (6 h), acceptable sequencing error rate, and portability of the sequencer, we anticipate that our developed protocol can become a powerful tool for studying emerging variants of MERS-CoV in the field during future outbreaks. The original contributions presented in the study are publicly available. This data can be found here in GenBank under accession number MT387202. The animal study was reviewed and approved by Korea Research Institute of Chemical Technology. Written informed consent was obtained from the owners for the participation of their animals in this study. Further evidence for bats as the evolutionary source of Middle East respiratory syndrome coronavirus Detection of a novel human coronavirus by real-time reversetranscription polymerase chain reaction Assays for laboratory confirmation of novel human coronavirus (hCoV-EMC) infections Sequential mutations associated with adaptation of human cytomegalovirus to growth in cell culture Universal amplification, next-generation sequencing, and assembly of HIV-1 genomes Whole-genome sequencing in outbreak analysis Close relative of human Middle East respiratory syndrome coronavirus in bat, South africa Comparative analysis of primer-probe sets for the laboratory confirmation of SARS-CoV-2. bioRxiv Variations in spike glycoprotein gene of MERS-CoV Complete genome sequence of Middle East respiratory syndrome coronavirus KOR/KNIH/002_05_2015, isolated in South Korea MEGA7: molecular evolutionary genetics analysis version 7.0 for bigger datasets A new pair of M13 vectors for selecting either DNA strand of double-digest restriction fragments Detection and full genome characterization of two beta CoV viruses related to Middle East respiratory syndrome from bats in Italy Viral load kinetics of MERS coronavirus infection Cell culture isolation and sequence analysis of genetically diverse US porcine epidemic diarrhea virus strains including a novel strain with a large deletion in the spike gene ViPR: an open bioinformatics database and analysis resource for virology research Multiplex PCR method for MinION and Illumina sequencing of Zika and other virus genomes directly from clinical samples Real-time, portable genome sequencing for Ebola surveillance From squiggle to basepair: computational approaches for improving nanopore sequencing read accuracy Genetic diversity of MERS-CoV spike protein gene in Saudi Arabia Genomic characterization of a newly discovered coronavirus associated with acute respiratory distress syndrome in humans Messenger RNA degradation: beginning at the end MinION nanopore sequencing of an influenza genome Laboratory Testing for Middle East Respiratory Syndrome Coronavirus: Interim Guidance (Revised) WHO MERS Global Summary and Assessment of Risk Diversity of Middle East respiratory syndrome coronaviruses in 109 dromedary camels based on full-genome sequencing Isolation of a novel coronavirus from a man with pneumonia in Saudi Arabia Viral load dynamics and disease severity in patients infected with SARS-CoV-2 in Zhejiang province, China The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.Copyright © 2021 Kim, Choi, Shin, Lee, Ku, Kim, Kim and Yi. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.