key: cord-0819001-v8lbp5rx authors: Liu, H.; He, S.; Shen, L.; Hong, J. title: Simulation-Based Study on the COVID-19 Airborne Transmission in a Restaurant date: 2020-12-14 journal: nan DOI: 10.1101/2020.12.10.20247403 sha: e199958d7fffa7a8cb1d69edf868be8fd59c8c89 doc_id: 819001 cord_uid: v8lbp5rx COVID-19 has shown a high potential of transmission via virus-carrying aerosols as supported by growing evidence. However, detailed investigations that draw direct links between aerosol transport and virus infection are still lacking. To fill in the gap, we conducted a systematic computational fluid dynamics (CFD)-based investigation of indoor air flow and the associated aerosol transport in a restaurant setting, where likely cases of airborne infection of COVID-19 caused by asymptomatic individuals were widely reported by the media. We employed an advanced in-house large eddy simulation (LES) solver and other cutting-edge numerical methods to resolve complex indoor processes simultaneously, including turbulence, flow--aerosol interplay, thermal effect, and the filtration effect by air conditioners. Using the aerosol exposure index derived from the simulation, we are able to provide a spatial map of the airborne infection risk under different settings. Our results have shown a remarkable direct linkage between regions of high aerosol exposure index and the reported infection patterns in the restaurant, providing strong support to the airborne transmission occurring in this widely-reported incidence. Using flow structure analysis and reverse-time tracing of aerosol trajectories, we are able to further pinpoint the influence of environmental parameters on the infection risks and highlight the needs for more effective preventive measures, e.g., placement of shielding according to the local flow patterns. Our research, thus, has demonstrated the capability and value of high-fidelity CFD tools for airborne infection risk assessment and the development of effective preventive measures. The COVID-19 pandemic (caused by the SARS-CoV-2) has led to more than 69 million infections and 1.5 million deaths as of writing. A growing number of evidence has suggested airborne transmission of respiratory droplets, either both produced from asymptomatic or pre-symptomatic individuals or none, is a potential pathway that contributes to the wide spread of the disease [1] [2] [3] [4] . In particular, an incidence in a restaurant in Guangzhou, China, where a single asymptomatic COVID-19 patient caused the infection of eight people sitting in the same and two adjacent tables, has been widely reported in the media 5,6 and recent scientific literature 1 as a hallmark demonstration of such transmission a) These two authors contributed equally b) Electronic mail: jhong@umn.edu pathway. Specifically, for airborne transmission, viruses attached to small respiratory droplets (typically < 5 µm, referred to as aerosols hereafter) produced by even normal breathing or talking can stay suspended in the air for hours, and they can accumulate, particularly in indoor spaces with poor ventilation, imposing high infection risk to individuals who inhale them [7] [8] [9] [10] [11] . Under such circumstances, the commonly adopted social distancing rules can no longer serve as a proper preventive measure 12 . As a result, there is a dire need for science-driven risk assessment tools that can provide actionable and more appropriate guidelines under different practical settings. Despite numerous analytical and numerical modeling work that provide the first order estimate of aerosol exposure and corresponding airborne infection risk [13] [14] [15] , only recently, the computational fluid dynamics (CFD) tools have been actively employed to provide a more precise risk assessment for aerosol exposure, especially, its spatial and temporal variations in indoor spaces. Specifically, using Reynolds-averaged Navier-Stokes (RANS) simulation with Lagrangian particle models, 16 investigated the airborne transmission risk associated with an asymptomatic patient is representative elevator, classroom, and grocery store settings. They introduced a local risk index and evaluated its spatial variation under different ventilation settings, which reveals indoor infection hot spots (corresponding to high risk of aerosol exposure) due to inappropriate ventilation design. Mathai et al. (2020) 17 Our simulation employs an advanced in-house CFD solver and uses cutting-edge numerical methods (i.e., advanced immersed boundary (IB) method, stochastic modeling of Brownian motion and effect of subgrid-scale (SGS) flow structures on aerosols, Cunningham slip correction, etc.) to resolve complex indoor processes, including turbulence, flowaerosol interaction, thermal effect, and the filtration effect by air conditioners. Such a combination of high-fidelity numerical methods, several of which has not been adopted in the past simulation work of indoor airflow, allows us to depict a detailed picture of airborne transmission in this hallmark incidence and derive a series of important insights that can benefit our understanding of this transmission pathway and the All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. ; https://doi.org/10.1101/2020.12.10.20247403 doi: medRxiv preprint development of more effective preventive measures. The rest of this paper is organized as follows. The methodology used in our simulation is described in Sec. II. Subsequently, we provide the results of simulation under different ventilation and thermal settings in conjunction with their potential connection with reported infection in Sec. III, with conclusions given in Sec. IV. In this study, LES is conducted, where the SGS stress is modeled by the dynamic Smagorinsky model [19] [20] [21] . The governing equations are where u is the velocity vector, ρ is the density, p is the pressure, ν is the kinematic viscosity, S = (∇u + ∇u T )/2 is the strain rate tensor, f B is the buoyancy force, τ sgs is the SGS stress tensor, f represents the forces exerted by the solid structures inside the room in the IB method, and the overbar denotes the spatial filter in LES. In the case where the turbulence in the inner boundary layer on the walls is not fully resolved, a log-law-based wall model 22 where T denotes the fluid temperature and α = 22.39 × 10 −6 m 2 /s is the thermal diffusivity. To couple the thermal effect with the airflow dynamics, the Boussinesq approximation 24 is applied to Eq. (2): where g is the gravitational acceleration, β = 3400 × 10 −6 /°C is the coefficient of thermal expansion and T o is the reference temperature. The influence of the solid structures on the flow dynam-ics is simulated by the IB method [25] [26] [27] [28] [29] . This method can be used on a static Cartesian grid to comply with the structure geometry, and is thus convenient to apply to structures with complex geometry. In the IB method, the velocity boundary condition is satisfied by interpolating the velocity to the grid points adjacent to the structure surfaces according to the velocity profile of the boundary layer. Linear and nonlinear interpolations are applied for cases where the boundary layer is resolved and modeled, respectively. The transport of aerosols is simulated with a Lagrangian particle tracking algorithm. The aerosol location x p is solved by where u p is the aerosol velocity obtained by In the above equation, the first and second terms on the right-hand side represent the Stokes drag force and gravity/buoyancy force, where ρ p and ρ f are the density of the aerosols and the fluid, respectively, u p is the aerosol veloc- ity, u f is the velocity of the fluid at the aerosol location, d is the aerosol diameter, V = 1 6 πd 3 is the aerosol volume, µ is the fluid dynamic viscosity, an aerosol whose center has a distance from the wall less than its radius is immediately removed from the computation domain. The effect of the SGS flows on the aerosol dynamics is accounted for by a stochastic model 36, 37 . In this model, the fluid velocity at the aerosol location u f is decomposed into a grid-resolvable part u f ,r and a SGS part u f ,s , where u f ,r is obtained by interpolating the flow velocity values on the grid nodes to the aerosol location by a fourth-order interpolation scheme and u f ,s is modeled by the following Langevin equation, where C s is the Smagorinsky coefficient, S is the filtered rate-ofstrain tensor, and each components of dξ is a Gaussian random variable with zero mean and variance dt. Equation (8) is integrated in time with an implicit algorithm for numerical stability. The aerosol volume fraction in the present study is φ = 4 × 10 −7 , which is much smaller than 10 −3 , the threshold of fourway coupling 30 . Therefore, the aerosol-aerosol interaction is not considered. Our numerical tools are validated by a forced convection case and a mixed convection case. See Appendix A for the validation details. The present numerical study is based on a real infection event that occurred in a restaurant in Guangzhou, China, which is illustrated in Fig. 1 . On January 24 th , 2020, there were 89 customers dining in the restaurant during the lunch time. After this lunch, nine people sitting on tables number one, two, and three [labeled in Fig. 1 (a) as T1, T2, and T3] were infected. The other people sitting away from these three tables were not infected 9 . It has been believed that three people eating at T1 and two people at T3 were infected directly during this lunch 1 . Virus was transmitted from patient zero sitting at T2. In order to simplify the discussion, customers are labeled as TAPBs as shown in Fig. 2 , where A stands for the index of the tables and B stands for the index of the customers. Our numerical simulations are set up with the configuration shown in Fig. 1 . A three-dimensional Cartesian coordinate system is used in the mathematical formulation and numerical discretization of the computational domain, in which the x-direction is set parallel to the longer wall of the room, the y-direction is set as the opposite of the direction of gravity, and the z-direction is set parallel to the shorter wall of the room. The origin is located at a corner shown in Fig. 1 (a). The length of the longer wall is 17.5 m, which is located at preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. To simulate the thermal effect by the human bodies around the tables and the hot food on the tables, a simplified model is implemented, as illustrated in Fig. 1 a hemispherical hot region is defined, which has a diameter the same as that of the round table below it, or the diagonal length of the rectangular table below it. In each hot region, the temperature is set by a constant T = T h . Moreover, the temperature of the air blown out of the AC outlets is set to be a constant T = T r , which is lower than T = T h . The temperature difference between them is denoted by is used to quantify the temperature variation in the flow field. Adiabatic condition is applied at the walls, floor, and ceiling. The initial temperature in the room is set as T = T r in the simulation. In the simulation, the height of the mouths of all the customers is set as h m = 1.3 m, based on the statistics of the averaged height of the sitting people 38 . Virus-laden aerosols are released from patient zero, which is marked by the red dot in All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. ; https://doi.org/10.1101/2020.12.10.20247403 doi: medRxiv preprint Cases 0.14 0.0 AC14DT10 0.14 10.0 AC112DT00 1.12 0.0 AC112DT10 1.12 10 .0 them will be re-ejected into the room randomly from the outlet of the AC. In the simulation, the filtration efficiency is set as f = 80%, based on the typical performance of HVAC systems 42 . To simulate the deposition effect, an aerosol will be labeled as deposited and deleted from the computational domain once the distance between the aerosol and the solid surface close to it (walls, tables, and ACs) is smaller than the radius of the aerosol. The computational domain in the present study has a grid and has the value Re = 6.8 × 10 4 , where ρ a is the density of air, U o = 1 m/s, and L o = 1 m/s, Four cases with various ventilation rate q AC and temperature difference ∆T are considered as shown in Table I . The range of q AC covers the common range of the ventilation rate of a HVAC system 43 . The temperature difference is based on the consideration of All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. the human body temperature, the food temperature, the room temperature, and the implementation of the simplified model shown in Fig. 1 The simulations were run with sufficient duration for the flow field to fully develop. Figure 3 shows the time evolution of the velocity variances u u , v v , and w w in case AC112DT10, where u , v , and w are defined in Eq. (13) , and · is the spatial-temporal average defined as where t 0 − ∆s < t < t 0 + ∆s is a time window expanding from t = t 0 that is long enough to cover the temporal fluctuations, To investigate the indoor flow structure, a temporal average is defined as where t 1 is a selected time instance after the total number of aerosols reaches dynamical balance in the simulation. Based on the temporal average, the flow field is decomposed into two parts: the mean flow and the turbulence, where u is the mean flow velocity and u is the turbulent All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. The exchange between the indoor and outdoor airs is investigated. To reduce the concentration of virus-laden aerosols, besides applying the filtration system, the most commonly used method is to keep exchanging indoor and outdoor airs. Fresh outdoor air can reduce the indoor aerosol concentration through the dilution effect. Figure 5 shows the streamlines of the mean flows traced backward from the restroom. As shown, the range covered by these streamlines varies with indoor conditions. The shortest range is from the tables in front of AC4 to the restroom, which occurs in cases AC14DT00 and AC112DT00, while the longest range is from the space in front of AC1 to the restroom, which happens in case AC112DT10. Figure 5 also shows that there are barely any streamlines near T1-3 that are directly connected to the restroom and thus it is less likely for the aerosols in this area to exit the restaurant, which is consistent with the measurement by Li et al. 9 . The turbulence is quantified by the turbulent kinetic energy (TKE), defined as and is displayed by the contours plotted near T1-3 in Fig. 6 . In Figs. 6(a) and (c), it is illustrated that the turbulence is mostly concentrated around the jet from AC1, in the two cases without considering thermal effect. Moreover, the TKE in preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. bulence. Another conclusion that is not directly shown from these results but is reasonable to expect is that the relative location between the tables and ACs also impacts the distribution of indoor turbulence. The indoor spatial-temporal distribution of the aerosols under various ventilation rates and thermal settings is quantified by the aerosol concentration C(x,t), which is defined as the number of aerosols per unit volume. The mean value of C during the statistical steady state, which is also called aerosol exposure index in this study, is used to quantify the temporally averaged distribution of aerosols or the degree of being exposed to the aerosols in the restaurant, which is numerically All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. calculated in the present simulations as where n i, j,k is the total number of aerosols that have been in the grid cell (i, j, k) at each timestep during the time period preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. ; https://doi.org/10.1101/2020.12.10.20247403 doi: medRxiv preprint four parts by substituting Eq. (13) into Eq. (6), preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. ; https://doi.org/10.1101/2020.12.10.20247403 doi: medRxiv preprint FIG. 7. Iso-surfaces of log 10 (C/C max ) = −1 (black) and log 10 (C/C max ) = −2 (yellow), and the contours of log 10 (C/C max ) in the planes at z = 2.6 m (across T1) and z = 6.8 m (across T3), in the simulation cases: (a) AC14DT00, (b) AC14DT10, (c) AC112DT00, and (d) AC112DT10. Here, C max is the maximum of C. 0.01C max in cases AC14DT10 and AC112DT10, because the rising plumes due to the thermal effect shown in Figs. 4(b) and (d) create a more complex drag force field. Moreover, Fig. 7(d) shows a preferential concentration on the T3 side than on the T1 side due to the transport by the stronger mean flow in case AC112DT10 compared with case AC14DT10. Since the infections at T1 and T3 are believed to be directly related with the airborne transmission 9 , more research All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. attentions are paid to the regions close to T1 and T3. The iso-surface of C/C max = −1.8 (the threshold is selected as a representative one based on the isolines concentrated near T1 and T3, see Figs. 9 and 11) and the mean flow streamlines near T1 and T3 are shown in Fig. 8 and Fig. 10 , respectively. The isolines of C/C max near T1 and T3 at the height of mouth h m are also displayed in Fig. 9 and Fig. 11 indicate that there exists a recirculation zone above T1 in cases AC14DT00 and AC112DT00. Inside the recirculation zone, the streamlines originate from the region around T2, first move towards the negative z−direction, and then gradually turn to T1 with a spiral-like trajectory. The recirculation zone above T1 is generated by the interaction among the walls, the surface of T1, and the local air flows. It is illustrated in Figs. 9(a) and (c) that from C/C max = −0.5 All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. to −1.8, the isolines of C/C max near T1 tend to be elongated while turning to T1. This pattern of spreading is due to the convection by the mean flow in the recirculation zone observed in Figs. 8(a) and (c). In Fig. 8(b) , two peaks on the iso-surface of C/C max = −1.8 are observed around T1 in case AC14DT10. The left peak is associated with a recirculation zone attached to the wall, which is formed by the thermal plume rising from T1 indicated by the red streamlines. Another peak is located between T1 and T2, where hot air passes through, indicated by the streamlines together with the green arrows in the Fig. 8(b) . Corresponding to the two peaks observed in Fig. 8(b) , it is illustrated in Fig. 9(b) that from C/C max = −0.5 to −2, the isolines of C/C max are preferentially distributed in the region between T1 and the All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. wall, where there is the recirculation zone, and in the region between T1 and T2, where the hot air flow caused by the thermal passes by. The spreading of aerosols to the first region is due to the convection by the thermal plume that generates the recirculation, and the spreading to the latter region is due to the convection by the hot air flow passing by. As for the case AC112DT10, it is found in Fig. 9 (d) that the magnitude of the gradients of aerosol exposure index |∇C| around the isoline of C/C max = −1.7 is significantly larger than those in the other cases, which indicates the less spreading of the aerosols in the region colored by dark blue in Fig. 9(d) . The less spreading is consistent with the observation in Fig. 8(d) . Near T1, the streamlines are directly connected to AC1, indicating that the aerosols in the dark blue region in Fig. 9 (d) are mostly transported by the mean flow along these streamlines. However, there are less aerosols concentrated in front of AC1 as shown All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. in Fig. 7(d) . Therefore, less aerosols are transported to the region near T1 in case AC112DT10. The irregular distribution of the isolines of C/C max in Fig. 9 (d) also indicates that the turbulence due to the thermal effect around T1, which is also illustrated in Fig. 6(d) , plays a role in dispersing the aerosols by exerting the turbulent shear force f t + f pt on the aerosols. To illustrate the aerosol exposure index near T3, Figs. 10(a) and (c) show the streamlines of the mean flow inside the iso-surface of C/C max = −1.8 in cases AC14DT00 and AC112DT00. Along these streamlines, the air moves from All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. ; https://doi.org/10.1101/2020.12.10.20247403 doi: medRxiv preprint the region close to patient zero to the wall and the inlet of AC1. The isolines of C/C max displayed in Figs. 11(a) and (c) are elongated in the same direction around T3, from C/C max = −1.2 to C/C max = −1.9. The elongation indicates the aerosol spreading, which is due to the transport by the mean flow shown in Figs. 11(a) and (c). Comparing Fig. 11(a) with (c), the isolines in the latter figure are sharper near the spot below AC1. This is because the stronger suction in case AC112DT00 exerts more forcing on the aerosols, which attracts more aerosols to AC1 compared with case AC14DT00. As shown in Figs. 11(b) and (d), in both the cases AC14DT10 and AC112DT10, there exists a peak of the iso-surface of C/C max = −1.8, which is located above the surface of T3. The isoline of C/C max = −2.1 in Fig. 11(b) indicates a local high aerosol exposure index region, which corresponds to the peak observed in Fig. 10(b) in case AC14DT10. Also in Fig. 11(d) , from C/C max = −1.4 to C/C max = −2.2, the elongation of the isolines above T2 corresponds to the peak observed in Fig. 10(d) . The streamlines in parallel with the green arrows in Figs. 10(b) and (d) indicate that the aerosol spreading in this region is due to the mean flow convection associated with the heated air to interact with the cold air in the jet above T3. Comparing the peak observed in case AC14DT10 with the one observed in case AC112DT10, the latter is located lower, because in the latter case, the cold jet from AC1 has stronger momentum, which makes the converging point closer to the surface of T3. In this section, first, a discussion about using the simulated results to predict the infection risk of COVID-19 is presented. Then, the simulation-based distribution of the infection risk is illustrated and explained by linking it to the analysis in Sec. III B. There are various factors that can determine the total infection risk of COVID-19 associated with airborne transmission. According to Mittal et al. 50 , the total infection risk R in is the product of the risk functions of a series of complex factors and processes, which can be expressed as where R fm is the infection risk due to the fluid mechanical factors (e.g., ventilation rate, temperature difference and initial All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. It is important to clarify that in the present study, only R fm , which is the risk due to the fluid mechanical factors, is analyzed based on the CFD results. The infection risk R fm is connected to the simulated aerosol exposure index distributions by an infection model 50 , which is illustrated in Fig. 12 . An exposure region in front of a person with volume 2000 ml is defined, and R fm is defined by averaging the mean virusladen aerosol exposure index inside the volume as where V e is the volume of the exposure region. The distributions of R fm of the customers sitting around T1 are shown in Fig. 13 . For the cases without the consideration of thermal effect, it is observed from Figs. 13(a) and (c) that in cases AC14DT00 and AC112DT00, T1P1 has the high-All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. est R fm , T1P3 has the lowest R fm , and T1P2 and T1P4 are in between. As illustrated by the aerosol exposure index and streamlines shown in Sec. III B, this distribution is due to the recirculation zone above T1, which creates a negative gradient of C, −∇C, roughly pointing from T1P1 to T1P3. For the cases with the consideration of thermal effect, Fig. 13(c) shows the similar trend in case AC14DT10 compared with the observations from Figs. 13(a) and (b) . However, the mechanism that leads to this distribution is different. T1P2 is lo-cated in a region where −∇C is roughly pointing from T1P1 to T1P2, due to the local thermal plume-formed recirculation zone, while T1P4 is located in a region where −∇C is roughly pointing from T1P1 to T1P4, due to the hot air flows passing by. T1P3 is located the furthest to T1P1. Moreover, comparing Fig. 13(d) with Figs. 13(a) , (c), and (d), it is observed that the R fm value in case AC112DT10 is around 10% of those in cases AC14DT10 and AC112DT00, and 1% of that in case AC14DT00, because T1P1-T1P4 are all located in the region All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. ; https://doi.org/10.1101/2020. 12.10.20247403 doi: medRxiv preprint where aerosols are less concentrated and most of the local air flows are directly from AC1. In the real infection event that occurred in this restaurant, T1P3 is the only person who was not infected during the lunch 9 . Without considering the factors beyond fluid mechanics, the present predictions around T1 in cases AC14DT00, AC14DT10, and AC112DT00 show a same trend as in the real infection. The R fm of the customers sitting around T3 is displayed in Fig. 14 . It is observed from Figs. 14(a)-(c) that the distributions of R fm in cases AC14DT00, AC14DT10, and AC112DT00 have an approximate V-shape, where the two ends have higher R fm than those in between. The difference is that the ratio between the left end in the V-shape distribution to the right is lower in cases AC14DT00 and AC112DT00 than in case AC14DT10. The V-shape distributions observed in cases AC14DT00 and AC112DT00 are due to the air flow sucked into AC1, which creates a distribution of −∇C above T3 roughly pointing from T3P7 to T3P4 and from T3P6 to T3P3. However, the V-shape distribution observed in case AC14DT10 is due to a more complex mechanism. Around T3P1 and T3P2, −∇C is created by the hot air flows interacting with the cold jet, while around T3P7 and T3P6, the ∇C is created by the hot air flow being sucked into AC1. Moreover, a distribution of a different shape is observed in case AC112DT10 in Fig. 14(d) , where the R fm values of T3P6 and P3P7 are much larger than those of the other five people (the ratios are higher than 2). Similar to the mechanism in case AC14DT10, the distribution of −∇C is due to the combined effect of the hot air flows being sucked by AC1 (around T3T7 and T3T6) and the hot air flows interacting with the cold jet (T3P2). The observed much higher risks of T3P6 and T3P7 is due to the stronger cold jet in case AC112DT10 that drives the concentrated region close to the surface of T3. In the real infection event, it is believed that T3P3 and T3P6 were infected during the lunch directly 9 . The prediction on the distributions of R fm does not show a higher R fm of T3P3 and T3P6 than other people. However, it shows the approximate V-shape distributions in cases AC14DT00, AC112DT00, and AC14DT10, which indicate that the people sitting at the two ends of the table have more risks than the ones in between, which is consistent with the real infection at T3. In this section, further discussions are provided based on the simulated results. First, we would like to offer some remarks on the applicability of our CFD for infection risk prediction. Specifically, our results have shown that CFD can provide detailed information on the spatial variation of aerosol concentration and aerosol exposure time as well as aerosol transport process to illustrate airborne transmission process and show remarkable agreement with infection pattern reported in the real scenario. Moreover, the CFD results can be used to systematically eval-All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. where n e and n eac are the total number of aerosols and the number of aerosols from AC1 that enter the exposure region during the averaging time. From Fig. 16(a) , it is shown that f ac can reach as high as 30% for the individuals sitting around T1 in case AC112DT10, due to the directional transport of aerosols through the air flows generated straight from AC1 as shown in Fig. 8 preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. from ACs is a potentially important factor when evaluating infection risks, and an increase of AC filtration efficiency is highly desirable for mitigating indoor infection risks. In this paper, we presented a systematic CFD-based investigation of indoor airflow and the associated aerosol transport All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. The data that support the findings of this study are available from the corresponding author upon reasonable request. Besides the inlet and outlet boundary conditions at the vents, no-slip boundary condition is applied on the walls and the partition. We compared the measured and simulated vertical velocity along two lines as shown in Fig. 17 , where Line 1 is parallel to the central axis of the inlet vent and Line 2 goes through the center of the partition. The comparison is plotted in Fig. 18 . As shown, the present LES result is very close to the experiment result. We have also conducted convergence tests on our numerical algorithm. We performed LES for Case 1 with the grid numbers of 80 × 30 × 45, 120 × 40 × 60, and 180 × 60 × 90. The comparison of the vertical velocity along Line 1 is plotted in Fig. 21 . As shown, our simulation algorithm obtains good convergence performance with different grid resolutions. Case 2 is about mixed convection, which was measured by Blay et al. 52 The set-up of this case is shown in Fig. 19 . All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. ; https://doi.org/10.1101/2020.12.10.20247403 doi: medRxiv preprint All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted December 14, 2020. ; https://doi.org/10.1101/2020.12.10.20247403 doi: medRxiv preprint COVID-19 outbreak associated with air conditioning in restaurant Pathogenesis and transmission of SARS-CoV-2 in golden hamsters Viable SARS-CoV-2 in the air of a hospital room with COVID-19 patients Airborne transmission of SARS-CoV-2: The world should face the reality This picture shows how 9 people in a restaurant got the coronavirus thanks to the placement of an air conditioning unit How coronavirus infected some, but not all, in a restaurant Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals Evidence for probable aerosol transmission of SARS-CoV-2 in a poorly ventilated restaurant Indoor transmission of SARS-CoV-2 Ventilation and laboratory confirmed acute respiratory infection (ARI) rates in college residence halls in The flow physics of COVID-19 Estimation of risk due to low doses of microorganisms: A comparison of alternative methodologies A methodology for estimating airborne virus exposures in indoor environments using the spatial distribution of expiratory aerosols and virus viability characteristics Estimation of airborne viral emission: Quanta emission rate of SARS-CoV-2 for infection risk assessment Risk assessment of airborne transmission of COVID-19 by asymptomatic individuals under different practical settings Airflows inside passenger cars and implications for airborne disease transmission Modelling aerosol transport and virus exposure with numerical simulations in relation to SARS-CoV-2 transmission by inhalation indoors General circulation experiments with the primitive equations: I. the basic experiment A dynamic subgridscale eddy viscosity model A proposed modification of the Germano subgrid-scale closure method A simple wall-layer model for large eddy simulation with immersed boundary method PETSc/TS: A modern scalable ODE/DAE solver library The validity of the Boussinesq approximation for liquids and gases Immersed boundary methods Immersed boundary methods for simulating fluid-structure interaction Level set immersed boundary method for coupled simulation of air/water interaction with complex floating structures A sharpinterface immersed boundary method for simulating incompressible flows with arbitrarily deforming smooth boundaries Fluid-structure interaction simulation of floating structures interacting with complex, largescale ocean waves and atmospheric turbulence with application to floating offshore wind turbines Turbulent dispersed multiphase flow The mean free path in air Airflow and particle transport in the human respiratory system Numerical simulation of aerosol deposition from turbulent flows using three-dimensional RANS and LES turbulence models Computational fluid dynamics simulation of airflow and aerosol deposition in human lungs Aerodynamic focusing of nanoparticles: II. Numerical simulation of particle motion through aerodynamic lenses Effect of vegetative canopy architecture on vertical transport of massless particles Numerical considerations for Lagrangian stochastic dispersion models: Eliminating rogue trajectories, and the importance of numerical accuracy Risk assessment of airborne transmission of covid-19 by asymptomatic individuals under different practical settings Exhaled respiratory particles during singing and talking Estimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin Preferential concentration of heavy particles in compressible isotropic turbulence Life and death of inertial particle clusters in turbulence Particles dispersion and deposition in inhomogeneous turbulent flows using continuous random walk models Two-particle dispersion in isotropic turbulent flows Lagrangian properties of particles in turbulence Three-dimensional models are sourced from the 3D library of the Microsoft application Paint 3D A mathematical framework for estimating risk of airborne transmission of COVID-19 with application to face mask use and social distancing Measurement and prediction of indoor air flow in a model room Confined turbulent mixed convection in the presence of horizontal buoyant wall jet All rights reserved. No reuse allowed without permission. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.