key: cord-0817321-vzdxnwrl authors: Cramer, Avilash K.; Plana, Deborah; Yang, Helen; Carmack, Mary M.; Tian, Enze; Sinha, Michael S.; Krikorian, David; Turner, David; Mo, Jinhan; Li, Ju; Gupta, Rajiv; Manning, Heather; Bourgeois, Florence T.; Yu, Sherry H.; Sorger, Peter K.; LeBoeuf, Nicole R. title: Analysis of SteraMist ionized hydrogen peroxide technology in the sterilization of N95 respirators and other PPE date: 2021-01-21 journal: Sci Rep DOI: 10.1038/s41598-021-81365-7 sha: f6fb43da065e8138174a5aa678b476db15132403 doc_id: 817321 cord_uid: vzdxnwrl The COVID-19 pandemic has led to widespread shortages of personal protective equipment (PPE) for healthcare workers, including of N95 masks (filtering facepiece respirators; FFRs). These masks are intended for single use but their sterilization and subsequent reuse has the potential to substantially mitigate shortages. Here we investigate PPE sterilization using ionized hydrogen peroxide (iHP), generated by SteraMist equipment (TOMI; Frederick, MD), in a sealed environment chamber. The efficacy of sterilization by iHP was assessed using bacterial spores in biological indicator assemblies. After one or more iHP treatments, five models of N95 masks from three manufacturers were assessed for retention of function based on their ability to form an airtight seal (measured using a quantitative fit test) and filter aerosolized particles. Filtration testing was performed at a university lab and at a National Institute for Occupational Safety and Health (NIOSH) pre-certification laboratory. The data demonstrate that N95 masks sterilized using SteraMist iHP technology retain filtration efficiency up to ten cycles, the maximum number tested to date. A typical iHP environment chamber with a volume of ~ 80 m(3) can treat ~ 7000 masks and other items (e.g. other PPE, iPADs), making this an effective approach for a busy medical center. www.nature.com/scientificreports/ germicidal irradiation, vaporized hydrogen peroxide, moist heat, ethylene oxide, and gamma irradiation [7] [8] [9] [10] [11] [12] [13] . In this study, we evaluate a recently developed technology, ionized hydrogen peroxide (iHP), as a method for sterilizing N95 masks and other PPE. Hydrogen peroxide (H 2 O 2 ) is a powerful sterilizing agent that can be used on porous and other surfaces following vaporization or ionization to create a mist containing hydroxyl radicals. Such vaporized or ionized hydrogen peroxide methods (VHP/iHP) are widely used for environmental sterilization across multiple industries including food preparation, healthcare, and life sciences [14] [15] [16] [17] [18] [19] . VHP/iHP methods can be used on a wider range of sensitive materials than high temperature methods such as autoclaving. Ethylene oxide (EtO) is another widely used cold sterilization method but use of EtO with face masks has been hindered by concerns about the carcinogenicity and toxicity of residual EtO. In contrast iHP is considered to be safer, as it breaks down to into water. Nonetheless, it is routine to test for the presence of residual H 2 O 2 post sterilization using an instrument such as a PortaSens II Portable Gas Leak Detector (Analytical Technology, Inc., Collegeville, PA) 20 . Four distinct VHP/iHP-based H 2 O 2 sterilization technologies have been commercialized to date and are shown in Table 1 . Each technology involves a different approach to generating and delivering the sterilant. In all cases microbial killing is achieved through the reaction of hydroxyl radicals with proteins, nucleic acids and other biomolecules in pathogens. Three VHP-based systems have received emergency use authorization (EUA) from the Food and Drug Administration (FDA) for N95 mask decontamination 21 , even though relatively limited peer-reviewed data is available 11 , particularly from non-commercial third parties. As a consequence, it is difficult for infection control teams in hospitals and other healthcare providers to evaluate and compare these systems. The absence of data on the post-sterilization performance of different makes and models of N95 masks is also limiting. The Brigham and Women's Hospital (BWH; Boston MA) Incident Command, which is involved in this study, currently has on hand over 30 models of N95 masks from three manufacturers. This study focuses on the use of iHP as a N95 mask sterilization method, specifically the SteraMist Binary Ionization Technology (BIT) from TOMI (Beverly Hills, CA). iHP was registered with the Environmental Protection Agency (EPA) in 2015 for use in health care, life sciences, food safety, and other settings (appearing on EPA lists G, H, K, L, and M). Most recently it was added to EPA List N: Disinfectants for Use Against SARS-CoV-2, for use on hard, nonporous surfaces 22 . The active ingredient in iHP is 7.8% aqueous H 2 O 2 which is flowed past a plasma arc and dispersed into a treatment chamber as a mist of micron-sized liquid droplets. The iHP method used in this study differs from the VHP method used by Battelle (based on Bioquell technology) in its "Critical Care Decontamination System" for sterilization of N95 masks primarily because iHP uses a ~ 5-fold lower H 2 O 2 concentration (7.8% vs. 30-35%; Table 1 ). Use of a lower H 2 O 2 concentration is possible because flowing H 2 O 2 through a plasma arc in an iHP system directly generates hydroxyl radicals, which are a powerful oxidizing agent that functions as the active sterilant (Table 1 ); in vapor-based systems hydroxyl radicals are generated by spontaneous decomposition of H 2 O 2 . iHP is commercially available in two implementations: a handheld sprayer device ("Surface Unit") and an environmental unit ("Environment System"). The environment system used in the current research was previously installed at the Dana-Farber Cancer Institute (DFCI; Boston, MA) animal research facility for use in sterilizing incoming equipment and materials; installations of this type are quite common. In this study, following cycles of sterilization, masks were tested for three critical features: (1) sterility, as measured by the inactivation of bacterial spores contained in biological indicators; (2) filtration efficiency, measured both by aerosolized 75 nm NaCl particles and by 0.3-1 µm ambient particulate matter; and (3) fit, using a PortaCount quantitative fit test apparatus. Multiple sterilization cycles were completed to assess mask durability. Sterilization of other PPE items such as face shields and hoods and hoses for Powered-Air Purifying Respirators (PAPRs) was also explored. Testing was performed at the DFCI, masks of the same model available in different sizes (for example, the 3M 1860 and the 3M 1860S, representing regular and small sizes) were considered to be interchangeable for testing purposes. The total sample size was necessarily limited by existing mask shortages and the importance of prioritizing the needs of healthcare workers; given the uniformity of the results reported below, the sample size was judged to be adequate. Additionally, an assortment of other PPE and hospital equipment was selected for sterilization. This included the following PAPR components: Sentinel XL CBRN hood with hose, Sentinel head cover hoods, Sentinel PAPR breathing tubes for use with Sentinel XL HP PAPR (ILC Dover, Frederica, DE), and Bullard RT Series PAPR hood (Bullard, Lexington, KY). Other equipment included two models of face shields, one locally fabricated 24 and the other a Fisherbrand Disposable Face Shield (Fisher Scientific, Waltham MA), a DuPont Tyvek 400 coverall (Wilmington, DE), an iPad (Apple, Cupertino CA), and an iPad case. The iPad was included for testing since BWH made them available to COVID-19 patients as a means of communicating with family members and there was an ongoing shortage of sterilizing wipes certified for use in this setting. A first set of 30 N95 masks representing five different models was processed in the SteraMist system for zero to ten cycles, and then analyzed for single-pass filtration efficiency using ambient particulate matter at MIT. A second set of 44 N95 masks was processed using the SteraMist system and sent to ICS Laboratories for testing to an abbreviated (instantaneous only) or full loading NIOSH N-95 filtration efficiency protocol. Nine masks underwent a quantitative fit test at DFCI following sterilization. N95 masks were placed with their interior surfaces facing up on standard stainless-steel shelves (open grid, InterMetro style). Most of the other PPE were also laid out on these shelves with the exception of two PAPR hoods, one PAPR hose, and a Tyvek coverall, which were hung in various configurations ( Supplementary Fig. S1 ). PPE was spaced 6 cm to 20 cm apart on each shelf; this was designed to test sterilization performance at multiple points in the chamber. Tighter but non-overlapping spacing would likely be necessary for processing equipment in higher volumes. However, as long as the chamber mist dwell time and iHP concentration are maintained at a constant level, tighter spacing should not affect the method's ability to effectively disinfect masks. Two PAPR hoods, one PAPR hose, and one face shield were pre-treated with a SteraMist handheld spraying device in advance of processing in the SteraMist-equipped chamber. Pre-treatment was intended to ensure delivery of sterilant to items with semi-enclosed surfaces (such as the inside of a PAPR hose). Staff who treated these items wore appropriate PPE, including goggles, an N95 respirator, and gloves, and used a handheld device to spray the equipment from a distance of approximately 0.5-1 m for a few seconds per surface. Per manufacturer protocol, the 100-min sterilization cycle in the environmental chamber included: program initiation, during which the inner and outer doors are locked to seal the room and a bubble damper closes over the exhaust to prevent air exchange; an initial 15-min fill phase during which the mist was released; a 20-min dwell phase to allow the mist to penetrate the room; a 65-min scrub phase during which the exhaust was re-opened to aerate the space at a rate of 43 air changes per hour; and program conclusion during which the room unseals. Following program conclusion, staff test for off-gassing using a PortaSens II Portable Gas Leak Detector Model C16 (Analytical Technology, Inc, Collegeville, PA) to ensure readings of H 2 O 2 < 1 ppm at the entrance and center of the room. Masks samples from the front, middle, and back of the room were also tested for off-gassing before removal. This was accomplished by briefly placing each sample in a 1 mil thick polypropylene plastic bag (dimensions: 20.3 cm × 10.2 cm × 45.7 cm) and monitoring the air inside the bag for H 2 O 2 using a PortaSens II Detector. The room is tested and calibrated quarterly for function by using enzymatic and biological indicators placed around the room (see below) and then ensuring homogeneous sterilization throughout the space. Evaluating sterility using biological indicators. The efficacy of sterilization was evaluated using Apex Biological Indicators (BIs: Mesa Labs; Boseman, MT); bacterial spores in these indicators are more resistant to killing than most viruses and therefore provide a conservative and simple estimate of sterilization efficacy. In particular, the Geobacillus stearothermophilus spores used in this study are known to be difficult to kill using hydrogen peroxide 6, 25, 26 . Each Apex biological indicator ribbon carries a minimum of 1.0 × 10 6 G. stearothermophilus spores. The BIs were positioned in the environmental chamber prior to the first sterilization cycle. For N95 masks, BIs were placed under or adjacent to the masks. For the PAPR components and other equipment, BIs were placed on surfaces that were judged to be least accessible to the sterilant (for example, inside the PAPR tubing) (Supplementary Table S1 ). The BIs were extracted using sterile forceps after 1 treatment cycle, placed in Releasat growth medium (Mesa Labs), incubated at 55-60 °C, and monitored for bacterial growth over a period of 10 days using a colorimetric assay 27 . Previous work with G. stearothermophilus spores suggests that a conservative benchmark for complete sterilization represents a 6-log 10 kill; that is, a ratio in the number of surviving www.nature.com/scientificreports/ to initial viable spores in a BI of 10 -6 (Ref. 28 ). This corresponds to no observable bacterial growth and thus no color change after 5 days in Releasat medium. Use of standard bacterial indicators were chosen over tests with SARS-Cov-2 virus for three reasons. First, spores in bacterial indicators (BIs) are known to be substantially more resilient to hydroxyl radicals than enveloped viruses 6 and it is well established that H 2 O 2 is an effective a sterilant for virus similar to coronaviruses 29 . Second, the primary question being addressed with bacterial indicators in the current work is whether hydrogen peroxide vapor is sufficiently dispersed in the treatment chamber to reach all PPE regardless of variation in placement. Third, studies with live virus would not generally be accessible to routine users of iHP methods. Instead, BIs provide a conservative and well-established measure of sterilization efficiency. Evaluating filtration efficiency. Single-pass filtration efficiency testing was performed at MIT on five control N95 masks and 25 masks sterilized in the SteraMist-equipped chamber. Filtration efficiency results obtained from this apparatus were compared to those obtained to NIOSH specifications at a commercial precertification laboratory (ICS Laboratories). Results with US-manufactured N95 masks (n = 10) exhibited good concordance between instantaneous filtration efficiency values measured using the MIT and ICS Lab tests, with a Pearson correlation coefficient of 0.89 (p = 0.0006). Additional information on the testing apparatus is available at cleanmask.org and in the literature 30 . For filtration testing at MIT, 8 cm × 8 cm sample of each N95 mask was inserted into a specialized air duct, with a cross-sectional area of 50.3 cm 2 ( Supplementary Fig. S2) , and ambient particulate matter was driven through the duct, and thus through the mask fabric, using a pressure differential of ~ 175 pascals at 0.4 m/s face velocity. The concentration of 0.3, 0.5, and 1 μm diameter particles prior to and after passage through the mask fabric was determined using an Aerotrak 9306 optical particle counter (TSI Inc.; Shoreview, MN) ( Table 2) . Filtration efficiency testing was performed a second time on a subset of decontaminated masks stored for 10 days after treatment to test for time-dependent degradation in N95 mask performance following sterilization. Although readily available, the testing performed at MIT is not equivalent to NIOSH-approved testing for N95 masks and thus, these results should be interpreted as a relative, not absolute, measurements of filtration efficiency. A second sample of sterilized N95 masks was tested at ICS labs to NIOSH standards with 34 masks undergoing an instantaneous filter efficiency test and 10 masks undergoing a full loading filter efficiency test. Testing was performed using a TSI Automated Filter Tester Model 8130A (TSI Inc., Shoreview, Minnesota). Per NIOSH testing Procedure No. TEB-APR-STP-0059 (rev. 3.2) 31 , all masks were challenged with a sodium chloride aerosol neutralized to a Boltzmann equilibrium state at 25 ± 5 °C and a relative humidity of 30 ± 10%. Particle size and distribution was verified to correspond to a median diameter of 0.075 ± 0.020 µm, with a geometric standard deviation ≤ 1.86. N95 masks were conditioned at 85 ± 5% relative humidity and 38 ± 2 °C for 25 h prior to filter efficiency testing. For instantaneous filter efficiency testing, each mask was then assembled into a fixture and subjected to instantaneous aerosol loading. The loading was performed by depositing sodium chloride aerosol at an airflow rate of 85 L per minute (LPM) for one minute. For full loading filter efficiency, each mask was assembled into a fixture and subjected to full aerosol loading. The loading was performed by depositing 200 mg of sodium chloride aerosol at an airflow rate of 85 LPM for 75 min. Flow rate was monitored every 5-10 min on average and adjusted to maintain a flow rate of 85 ± 2 LPM. Quantitative fit testing. Nine masks from three models underwent a quantitative fit test following 2, 5, and 10 sterilization cycles to confirm that sterilization did not interfere with the ability of masks to form an effective seal with the human face. Testing was performed with the full set of OSHA prescribed wearer exercises using a PortaCount Pro + 8038 fit tester (TSI Inc.; Shoreview, MN) set to the 100-200 fit factor range, per manufacturer recommendation. Ethics approval. Ethics approval was not necessary to conduct this study. Evaluating sterilization using biological indicators. All BIs placed under or adjacent to N95 masks that had been exposed to a single sterilization cycle in the SteraMist-equipped chamber exhibited at least a 9-log 10 kill (representing no color change following seven days of incubation in Releasat medium). BIs placed within PAPR hoods also achieved 9-log 10 kill as did a BI placed in a PAPR hose that was pre-treated using a SteraMist handheld spraying device (Supplementary Table S1 ). BIs placed on the iPad, iPad case, and PanFab face shield designs 24 all passed the sterilization threshold, and the iPad was observed to be fully functional after one cycle of iHP treatment. In contrast, two BIs placed inside either end of a PAPR hose that was not subjected to pre-treatment were not sterilized, as determined by rapid bacterial growth following transfer to Releasat medium. This was also true of a BI embedded in the thick foam at the top of a Fisherbrand Disposable Face Shield. We tested the effect of pretreating the same face shield with a hand-held SteraMist device (after inserting a new BI) and observed a 4-log 10 kill, which also fails the 6-log 10 threshold conventionally used to score successful sterilization. From these data we conclude that a single iHP cycle is efficacious at sterilizing N95 masks and other equipment having readily accessible surfaces when the equipment is placed throughout a SteraMist-equipped decontamination chamber. Moreover, the process is not obviously damaging to delicate equipment such as an iPad (n = 1). Penetration into semi-enclosed spaces such as PAPR hoses appeared to be less efficient, but such equipment could be sterilized by pre-treatment with a handheld iHP-delivery device followed by a cycle of iHP treatment in a chamber. This suggests that forced ventilation of hoses, with a small fan for example, would enable hands-free sterilization of hoses but we were unable to test this possibility. We found that iHP vapor did not www.nature.com/scientificreports/ penetrate 2.5 cm foam on a disposable face shield at sufficient concentrations to sterilize biological indicators, even following pre-treatment with a handheld device. These data suggest that normally disposable face shields should not be reused. In contrast, a custom-fabricated face shield 24 introduced under an FDA EUA and consisting of 3D printed parts and closed cell Ethylene-Vinyl Acetate (EVA) foam appeared to be sterilized effectively. Further research is required to understand the factors (e.g. open vs. closed cell construction) that determine whether foams and similarly compliant materials can be sterilized with iHP vapor. Evaluating filtration efficiency. Performance data was collected at MIT on five models of N95 masks from three manufacturers (a total of 30 units) using an ambient particulate matter filtration efficiency test. Relative to control N95 masks, we observed no reduction in filtration efficiency for 0.3, 0.5, and 1 µm particles by N95 masks subjected to up to ten sterilization cycles ( Table 2) . Data on pressure, temperature, air face velocity, and relative humidity during testing are found in Supplementary Table S2 . In addition, five N95 mask models from three manufacturers (44 units total) were evaluated using testing protocols derived from NIOSH published standard testing procedures (STPs) maintained by ICS Laboratories. These data showed that all 34 iHP-sterilized N95 masks retained instantaneous filtration efficiencies of ≥ 95%, including masks subjected to ten sterilization cycles, the maximum number of cycles tested (Fig. 1, Tables 3, 4 , and Supplementary Table S3 ). Gerson 2130 N95 masks were the least effective at filtering 75 nm NaCl particles, but even these units passed the instantaneous test threshold out to five sterilization cycles (the maximum number tested for this model). Per NIOSH standards, inhalation resistance should not exceed 35 mm of H 2 O and exhalation resistance should not exceed 25 mm of H 2 O 32 . No mask exceeded these thresholds, and in no case did users perceive increased resistance to airflow during normal breathing. www.nature.com/scientificreports/ Fully loaded filtration efficiency was also evaluated by ICS Laboratories to NIOSH standards. The purpose of this test is to mimic the effect of an accumulation of charged particles in a mask, a phenomenon related to time of use. Mask loading is known to lower filtration efficiency, potentially by reducing the electrostatic charge of fabric in the filtering layer 33 . Again, we observed that the 10 sterilized masks subjected to this test passed the NIOSH threshold for N95 pre-certification. To test for time-dependent degradation of performance, 26 N95 masks were stored for ten days after initial filtration testing and then re-tested using the MIT apparatus (Supplementary Table S4) ; the time between iHP sterilization and retesting varied between 10-15 days depending on cycle number. We observed no difference in filtration performance between measurements taken immediately after sterilization, and those taken 10 days after, as determined by a repeated measures ANOVA (p = 0.45). From these data we conclude that the filtration Figure 1 . Instantaneous and fully-loaded ambient particulate matter filtration data for N95 masks over one, two, five, and 10 SteraMist sterilization cycles (1 ×, 2 ×, 5 ×, and 10 × respectively). "KC" corresponds to Kimberly-Clark. Figure marker color corresponds to mask model type (listed on y-axis). Results were obtained from ICS Laboratories according to NIOSH standard Procedure No. TEB-APR-STP-0059. All masks passed ICS standards, including filtration efficiency of ≥ 95%. Table 3 . Results from ICS Laboratories on instantaneous filtration efficiency according to NIOSH standard Procedure No. TEB-APR-STP-0059 (the flow rate was 85-86 LPM). Each row represents data from one to five N95 masks of a particular model and data are reported as the average for all tests that were performed. In contrast to the data in Table 2 , each mask was measured only once and standard deviations are therefore reported only when the number of masks was greater than one. 3M 1860 www.nature.com/scientificreports/ efficiency of multiple models of N95 masks is not substantially affected by one to ten cycles of iHP sterilization in terms of filtration efficiency or inhalation resistance, and that all masks tested meet existing NIOSH precertification standards. PortaCount quantitative fit data. All nine masks that were subjected to quantitative fit testing (KC/ Halyard 46767, 3M 1860, 3M 8210) using PortaCount equipment achieved a passing value of > 200 fit factor following 2, 5, and 10 sterilization cycles. This corresponds to a filtration efficiency of 99% or higher (data not shown) according to manufacturer guidelines. Thus, iHP sterilization does not appear to impair the ability of N95 masks to form an effective seal against a user's face. Hydrogen peroxide has a long history of successful use in the field of medical device sterilization, and our results support the use of iHP as a PPE sterilant when delivered using a SteraMist-equipped environment chamber, in some cases complemented by pre-treatment with a handheld iHP delivery device. Thus, iHP sterilization can likely be used to extend the usability of PPE such as N95 masks that are usually disposed of after a single use. The DFCI SteraMist environment chamber used in this study has a volume of ~ 80 m 3 and could comfortably fit ~ 2400 N95 masks per cycle without the masks touching each other, or a lesser number of PAPR hoods and other PPE. At this rate, assuming idealized staffing and logistics, roughly 4800-7200 masks could be sterilized for use per day given a typical 100 min sterilization cycle. These numbers could be increased with the addition of an overnight workforce. In keeping with standard practice, sterility was judged in this study using biological indicators containing bacterial spores and was not based on killing of pathogens such as SARS-CoV-2 encountered in a clinical setting. However, the G. stearothermophilus spores in the BIs we used are known to be resistant to killing by hydrogen peroxide, and spores are substantially more resistant to sterilization than enveloped viruses such as SARS-CoV-2 34 . Recent work has also demonstrated that VHP can kill SARS-CoV-2 11, 19, 35 . Thus, we do not believe that our use of BIs rather than direct measurement of viral viability represents a significant limitation in the interpretation of the data. Two independent lines of evidence, one generated at a university laboratory and one at a commercial laboratory accredited to perform N95 mask certification to NIOSH/ISO/IEC standards, show that N95 masks decontaminated with iHP using SteraMist technology retain their performance with respect to filtration and inhalation resistance for at least ten cycles, the maximum number tested. No deterioration was detected in masks tested 10 days post treatment. Quantitative fit testing of N95 masks sterilized up to ten cycles confirmed that they still form an airtight seal as required. Thus, sterilized N95 masks remain fully functional. Limitations of this study. The tests described in this study were conducted using unused N95 masks. We do not yet have data on N95 masks used in an actual health care facility responding to a pandemic. Such studies are important for assessing the real-world implication of mask reuse. Previous work has found that masks subjected to multiple donnings and doffings fail fit testing 36 although potential solutions to this problem have been proposed 37 . Additional questions that must be addressed by real-world testing include inhalation resistance for an N95 mask that has been loaded with internal and external contaminants, the comfort level of health care workers in using an N95 mask that is sterilized but previously used by another individual, and the rate of wastage arising from breakage of elastic bands, and contamination with makeup or topical face products. These types of real-world use data are not available for any iHP/VHP-based sterilization method, even for technologies that have been promoted commercially, in part because testing masks potentially contaminated with SARS-CoV-2 is not feasible on standard equipment. Nonetheless, the data reported in this study were judged by our clinical teams to be sufficient to implement N95 mask sterilization and reuse at DFCI. www.nature.com/scientificreports/ Future work should address the question of whether decontaminated N95 masks must be returned to the original users (as specified in the Sterrad and Sterris EUAs for N95 mask decontamination) or can be returned to a common pool (as specified in the Batelle EUA); the latter is substantially easier to implement from a logistical perspective. Additional work is also required to determine whether mechanical ventilation would make it possible to sterilize PAPR hoses and similar devices without the need for manual pre-treatment. Additionally, while there is good support for the use of spore-based BIs in measuring the efficacy of sterilization, direct tests on SARS-CoV-2 itself may be warranted, particularly in the case of items such as hoses and other PPE that have a complex shape. Finally, while we determined that masks did not release detectable H 2 O 2 following sterilization, we did not assess the effect of time after sterilization on off-gassing: we simply used the manufacturer's recommended venting protocol. Our data support the use of the SteraMist iHP technology as a sterilization method for reuse of N95 masks, including many of the most commonly used models, as well as some other types of PPE-in some cases following pre-treatment with an iHP handheld delivery device. In interpreting these data, it is important to note that not all iHP/VHP methods are the same. While Bioquell is approved under an FDA EUA for 20 cycles, N95 masks sterilized using an alternative HPGP method commercialized by Sterrad fail at five cycles (the Sterrad EUA was approved for 2 sterilization cycles and requires that a mask be returned to a single user) 11, 38 . Moreover, our data show that semi-enclosed items of PPE, such as PAPR hoses, cannot be sterilized without pre-treatment, and that face shields with thick foam may not be sterile even after exposure to iHP using a handheld device followed by an environmental chamber. Thus, it is imperative that institutions seeking to deploy iHP/VHP technology review primary data prior to local deployment. We also suggest that BIs routinely be deployed to ensure equipment performance. The issues attending reuse of N95 masks have been recognized for over two decades based on multiple instances of human transmission of novel respiratory diseases. As the global response to COVID-19 evolves, we hope that the study of sterilization technologies such as iHP/VHP will continue and involve peer-review of independently acquired data so that we are in a better position for coming waves of the current pandemic and possible pandemics in the future. All data relevant to the study are included in the article or uploaded as supplementary information. Correspondence and requests for materials should be addressed to P.K.S. Reprints and permissions information is available at www.nature.com/reprints. Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creat iveco mmons .org/licen ses/by/4.0/. HHS clarifies US has about 1% of face masks needed for 'full-blown' coronavirus pandemic Potential demand for respirators and surgical masks during a hypothetical influenza pandemic in the United States Better Respiratory Equipment Using Advanced Technologies for Healthcare Employees COVID-19) Reusability of Facemasks During an Influenza Pandemic: Facing the Flu. 11637 Final Report for the Bioquell Hydrogen Peroxide Vapor (HPV) Decontamination for Reuse of N95 Respirators Evaluation of multiple (3-cycle) decontamination processing for filtering facepiece respirators Effect of decontamination on the filtration efficiency of two filtering facepiece respirator models Evaluation of five decontamination methods for filtering facepiece respirators Disposable N95 masks pass qualitative fit-test but have decreased filtration efficiency after cobalt-60 gamma irradiation N95 mask decontamination using standard hospital sterilization technologies Inactivation and safety testing of Middle East Respiratory Syndrome Coronavirus A scalable method of applying heat and humidity for decontamination of N95 respirators during the COVID-19 crisis Hydrogen peroxide vapor sterilization of N95 respirators for reuse Use of hydrogen peroxide vapor for deactivation of Mycobacteriumtuberculosis in a biological safety cabinet and a room Decontamination with vaporized hydrogen peroxide is effective against Mycobacteriumtuberculosis Use of vaporized hydrogen peroxide decontamination during an outbreak of multidrug-resistant Acinetobacterbaumannii infection at a long-term acute care hospital Decontamination and reuse of N95 respirators with hydrogen peroxide vapor to address worldwide personal protective equipment shortages during the SARS-CoV-2 (COVID-19) pandemic Assessment of N95 respirator decontamination and re-use for SARS-CoV-2 Analysis of residual chemicals on filtering facepiece respirators after decontamination Fact Sheet for Healthcare Personnel on Emergency Use of STERRAD ® Sterilization Systems to Reprocess N95 Respirators Disinfectants for Use Against SARS-CoV-2. US EPA National Framework for Personal Protective Equipment Conformity Assessment-Infrastructure Rapid prototyping and clinical testing of a reusable face shield for health care workers responding to the COVID-19 pandemic Low-temperature decontamination with hydrogen peroxide or chlorine dioxide for space applications Use of hydrogen peroxide as a biocide: New consideration of its mechanisms of biocidal action US Environmental Protection Agency and Office of Pesticide Programs. Protocol for Room Sterilization by Fogger Application Decontamination and reuse of surgical masks and N95 filtering facepiece respirators during the COVID-19 pandemic: A systematic review Assessing the quality of nontraditional N95 filtering face-piece respirators available during the COVID-19 pandemic National Institute for Occupational Safety and Health and National Personal Protective Equipment Technology Laborator. Determination of particulate filter efficiency level for N95 series filters against solid particulates for non-powered, air-purifying respirators standard testing procedures Code of Federal Regulations (42 CFR 84.180) Airflow resistance tests Particle loading time and humidity effects on the efficiency of an N95 filtering facepiece respirator model under constant and inhalation cyclic flows Healthcare and Infection Control Practices Advisory Committee (HICPAC) Vapor H 2 O 2 sterilization as a decontamination method for the reuse of N95 respirators in the COVID-19 emergency Impact of multiple consecutive donnings on filtering facepiece respirator fit 3D Printed frames to enable reuse and improve the fit of N95 and KN95 respirators US Food and Drug Administration US Food and Drug Administration US Food and Drug Administration Steris Corporation Cold plasma-activated hydrogen peroxide aerosol inactivates Escherichiacoli O157:H7, Salmonellatyphimurium, and Listeriainnocua and maintains quality of grape tomato, spinach and cantaloupe Above all we thank the members of the Greater Boston Pandemic Fabrication Team (PanFab) for technical, administrative, and logistical support necessary for the execution of this project. Membership found at https :// www.panfa b.org/the-team-and-the-proje ct/conso rtium -membe rs. We also thank Prof. Mike Short (MIT Nuclear science and Engineering); Karen Byers (DFCI Biosafety); Chad Pires (Boston Children's Hospital Environmental Safety); and Dale Pfriem along with the employees of ICS Laboratories for performing N95 mask testing under challenging conditions. A.K.C., D.P., and H.Y. contributed equally to this paper. Study conception and planning: This study was funded by the National Cancer Institute Grants (Nos. P30-CA006516 and U54-CA225088) and the National Institutes of Health (No. T32-GM007753). All authors have completed the ICMJE uniform disclosure form at http://www.icmje .org/coi_discl osure .pdf and declare: no support from any organization for the submitted work; no financial relationships with any organizations that might have an interest in the submitted work in the previous three years; no other relationships or activities that could appear to have influenced the submitted work. PKS is a member of the SAB or Board of Directors of Applied Biomath, Glencoe Software and RareCyte Inc and has equity in these companies. In the last five years the Sorger lab has received research funding from Novartis and Merck. Sorger declares that none of these relationships are directly or indirectly related to the content of this manuscript. NRB is a consultant for or has received honoraria from the following companies: Seattle Genetics, Sanofi, and Bayer. The authors have no affiliation with and received no compensation from TOMI Environmental Solutions, Inc and TOMI played no role in the design of the study. The authors corresponded with members of TOMI Corporation concerning the technical specifications of the SteraMist system. The other authors have no competing interests or interests that could be perceived to influence the results and/or discussion reported in this paper.