key: cord-0815810-vxa98jmb authors: Masoomi, Michael A; Al-Kandari, Latifah; Al-Shammeri, Iman title: Combining 3D rendering model and pixelated quantitative CT for rapid assessment of lung affected with COVID-19 and need for oxygenation date: 2021-01-29 journal: BMJ Case Rep DOI: 10.1136/bcr-2020-241060 sha: bc22831b5e12ada48cbb2c5f9f3f378e81bda768 doc_id: 815810 cord_uid: vxa98jmb nan A 35-year-old man with dyspnoea, tachycardia and history of having cough, fever and headache was referred to the hospital cardiac centre. The initial diagnosis suggested pulmonary embolism but COVID-19 was also in the differential diagnosis. Clinical chemistry and haematology lab tests revealed elevated C-reactive protein (128.10 mg/L), ferritin (272 ng/mL), D-dimer (600 ng/mL), WBC (9.2×10 9 /L), Erythrocyte Sedimentation Rate (5 mm/hour) and normal lymphocytes (2.61×10 9 /L). An area of veiling was seen in the lower left lung (LLL) zone on the X-ray of the chest. A contrast multidetector CT angiography to rule out pulmonary embolism appeared normal with no pulmonary nodule, mass, pleural or pericardial effusion, consolidation or ground glass opacity. However, the real-time PCR was positive for COVID-19. A quantitative colour-pixelated CT map (QCT) using a tailored Matrix Laboratory was produced to display Hounsfield unit numbers of the entire CT images of the patient lung affected with COVID-19 for setting up accurate threshold values to generate a three-dimensional (3D) volumetric model of the compromised lung: total lung volume (−1024 to 100), air (−1024 to −820), healthy tissue (−1025 to −500) and COVID-19 region (−500 to 100). It has been reported that GGO is associated with modest increases in lung attenuation on lung window CT images. 1 The QCT images clearly showed the various elevated density levels ( figure 1A-C) . The patient was kept under observation and treated with azithromycin, vitamin C and D, Zink and Xarelto10 (as prophylaxis) according to the hospital protocol at the time. The follow-up clinical examination reported improved dyspnoea, no coughing, but elevated temperature (39.5°C) and the high-resolution CT images revealed a developed area of ground glass veiling appearance and atelectatic band in the LLL ( figure 1D-F) . No bronchiectasis and no pleural or pericardial effusion were present. The Materialize Mimics Care Suite modelling (research version) was used to generate a 360° viewing model of the patient lung, in a virtual reality concept, for rapid assessment and quantification of COVID-19 with reference to the locality and the global lung volume in one capsulated view. An initial 3D model of a known body volume was generated with an error of −1%. The ratio of the volumes of the infected COVID-19 to the total lung measured at 4%, suggested a mild volume based infection with no oxygenation need (figure 2H-I). The 3D lung at two timepoints showed a noticeable improvement in air and tissue volumes post treatment (figure 2A-F). To identify any air trapping, the colour expiratory and inspiratory CT were compared. Several recent publications have described features and evolution of COVID-19 CT images overtime 2-6 though, currently viral RT-RNA remains the gold standard, but cannot assess the severity of the disease and false-negative results are not common. 7 We quantified air to soft tissue lung volumes to be 4.3%, 1.5% and 77.8%, 72.0% before and after treatment for the right and the left lung as the predictor of oxygenation support. The SpO 2 measured was 93% and 96% and the calculated ratio of PaO 2 /FiO 2 was 256 mm Hg and 360 mm Hg at pre and post treatment. Diagnosis of the coronavirus disease (COVID-19): rRT-PCR or CT? Ct imaging features of 2019 novel coronavirus (2019-nCoV) Chest imaging appearance of COVID-19 infection Chest CT findings in coronavirus Disease-19 (COVID-19): relationship to duration of infection Time course of lung changes on chest CT during recovery from 2019 novel coronavirus (COVID-19) pneumonia Performance of radiologists in differentiating COVID-19 from Non-COVID-19 viral pneumonia at chest CT Evaluating the accuracy of different respiratory specimens in the laboratory diagnosis and monitoring the viral shedding of 2019-nCoV infections Acknowledgements The authors would like to thank Haytham Ramzy MD, at the Radiology Department-Adan for clinical discussion, Hany A Elrahman for valuable assistance in processing technical data and all the supportive research colleagues. Competing interests None declared. Provenance and peer review Not commissioned; externally peer reviewed.This article is made freely available for use in accordance with BMJ's website terms and conditions for the duration of the covid-19 pandemic or until otherwise determined by BMJ. You may use, download and print the article for any lawful, non-commercial purpose (including text and data mining) provided that all copyright notices and trade marks are retained. Michael A Masoomi http:// orcid. org/ 0000-0003-0542-5924Learning points ► Quantitative CT combined three-dimensional (3D) lung volume provide a new metric of COVID-19 and is seen as the ideal tool that could predict which patient will need oxygenation or a mechanical ventilator soon or who no longer requires one, especially in situations with limited hospital resources. ► The generated 3D 360 visual rendering model of COVID-19 lung as well as a 3D printing model can be served on a mobile and accessible effective platform (eg, IPhone) for training and educating patients and public to promote the healthcare in a broader spectrum.