key: cord-0814452-z1a2jopl authors: Khanyi, Halalisiwe B.; Naicker, Bavani title: The use of point-of-care ultrasound in a regional emergency department in KwaZulu-Natal, South Africa date: 2021-08-23 journal: S Afr Fam Pract (2004) DOI: 10.4102/safp.v63i1.5269 sha: 4c597c548121baa529527afa9222933fe0d1ddf4 doc_id: 814452 cord_uid: z1a2jopl BACKGROUND: Formal ultrasonography has advanced to point-of-care ultrasound (POCUS) in the emergency department (ED) for the purpose of acute critical care. While POCUS application expands, little is known about POCUS utilisation in public hospital EDs. This study aimed to describe the use of POCUS in an ED in KwaZulu-Natal. METHODS: A retrospective chart review study was conducted on all patients who had POCUS exams performed in the ED at the General Justice Gizenga Mpanza Regional Hospital from 01 September 2019 to 31 March 2020. A data collection tool was used to extract the required data from the Mindray M6 ultrasound machine. The data were processed using the Statistical Package for Social Sciences (SPSS version 26) and descriptive statistics were used to summarise the data. RESULTS: A total of 978 POCUS were performed on 784 patients. Point-of-care ultrasound was utilised more often for focused emergency echocardiography in resuscitation (n = 383) and extended focused assessment with sonography for trauma (n = 319). The findings were normal in 17% of exams, 31% were positive, 9% were unspecified and 43% of POCUS exams were inconclusive. Seven percent of POCUS exams were performed by accredited level 1 emergency POCUS providers and ultrasounds occurred more frequently during day-shift hours than after-hours. CONCLUSION: Point-of-care ultrasound core applications were utilised by ED doctors for various emergency care scenarios, mainly for trauma and cardiac assessments. The burden of trauma and medical diseases in South Africa is high. 1, 2 Public hospital emergency departments (EDs) are the first point of contact for various medical and trauma emergencies, with many of these healthcare facilities limited to plain radiography services. Although resource limitations persist, there has been an increase in the number of emergency medicine specialists in the EDs since the introduction of the specialty in 2003 and an advance in accredited level 1 emergency point-of-care ultrasound (POCUS) providers in the country. Ultrasound is a safe, repeatable, non-invasive and cost-effective diagnostic tool. Point-of-care ultrasound is practiced in austere environments for applications related, but not limited, to battlefield triage, in-flight examination of critically ill transfers and screening at high altitudes for high-altitude emergencies; additionally, in-hospital facilities such as the operating theatre (OT) and EDs use POCUS. 3 In the ED, POCUS has shown to be quick, focused, goal-directed with minimal delay or need for specialised technical personnel. Point-of-care ultrasound has been well-established, validated protocols for use in acute emergencies. The integration of the extended-focused assessment with sonography for trauma (e-FAST) in the initial assessment for suspected thoraco-abdominal injury has shown to have a therapeutic impact in patients with severe trauma, and the accuracy of lung ultrasound has also shown to be superior to that of chest radiography in the detection of a pneumothorax. 4, 5 The use of focused cardiac ultrasound (FOCUS) has aided in diagnostic assessments, monitoring, therapy titration and procedural guidance in critically ill patients at the bedside. 6 While studies have emerged noting potential harm of POCUS in prolonging cardiopulmonary resuscitation (CPR) pause duration, advances in resuscitation strategies during cardiac arrest and following return of spontaneous circulation (ROSC) have incorporated POCUS as a tool for detection of reversible causes of pulseless electrical activity (PEA). 7, 8, 9 Retrospective analyses have demonstrated the ability of emergency physicians to perform colour Doppler ultrasound and reduce time-to-disposition of patients while also maintaining good correlation in results during screening for deep vein thrombosis (DVT) 10, 11 ; additionally, a bedside abdominal aortic aneurysm ultrasound performed by an emergency physician has shown to be accurate and fast. 12 Emergency physicians have also demonstrated proficiency in evaluating patients at risk of ectopic pregnancy, detecting hydronephrosis in suspected ureteral colic and diagnosing ocular pathology in ED. 13, 14, 15, 16 The traditional paradigm of ultrasonography being performed by radiologists may become replaced by the POCUS paradigm in the ED as more methods of POCUS utility are described and published for acute critical care. The purpose of this study was to describe the use of POCUS in an ED in KwaZulu-Natal, South Africa. The study was conducted at General Justice Gizenga Mpanza Regional Hospital (GJGMRH) which is the only regional hospital in the public sector in the Ilembe district, located 47 km from King Shaka International Airport. To date, the Ilembe district has over 600 000 residents with 55% of people living below the poverty line, 26.6% unemployed and only 7.9% of the population with medical aid coverage. 17 The ED at GJGMRH receives direct referrals from the nine district clinics, the community health centres, district hospitals and general practitioners and accepts self-referrals. This study was a retrospective chart review of POCUS performed in the ED at GJGMRH from 01 September 2019 to 31 March 2020. This was a purposive sampling strategy of all patients in the ED at GJGMRH that had POCUS exams performed using the Mindray M6 ultrasound machine. As it was a descriptive study design, power analysis was not conducted. All patients who had POCUS exams performed using the Mindray M6 Premium Portable Ultrasound were included for the study. This model of ultrasound machine provided accurate information on frequency of use as it automatically captured date and time for every use. • Patients who had POCUS exams performed using an alternative ultrasound machine were excluded, as necessary data could not be retrieved from that model of ultrasound machine. • Patient hospital folders and paper-based POCUS reports were also excluded to reduce inconsistency in coding of chart information and missing charts. • Paediatric patients with clinical presentations relating to medical causes, as these were assessed by the paediatric outpatient department (POPD). • Point-of-care ultrasound exams performed using the Mindray M6 ultrasound before and after the study period. The data were collected from the Mindray M6 ultrasound's internal hard drive. The iStationTM (Mindray's Patient Information Management System) was used to retrieve, review and assess the ultrasound entries in chronological order. A data collection tool was then used to collect the data needed for the study with all information fully anonymised with no key to the identity of the data subjects. During the study period, there was a total of 964 study participants who met the inclusion criteria. One hundred and eighty of those participants only had a record of time and date saved. These participants were subsequently excluded because they had no record of POCUS type(s), images, video clips or PDF data saved. Therefore, most of the data on POCUS were based on 784 study participants (Figure 1 ). The mean age of the studied population was 42.89 with a standard deviation of ±20.62 years. The male population had more POCUS exams (54.04%) than that of the opposite gender (45.96% were female). From 01 September 2019 to 31 March 2020, a total of 978 POCUS exams were performed using the Mindray M6 ultrasound machine (Figure 2 ). The findings were normal in 17% of POCUS exams, positive in 31% of exams, 9% of exams were unspecified in terms of POCUS type and 43% of POCUS exams were inconclusive. Different types of POCUS were performed at variable frequencies ( Figure 3 ). Point-of-care ultrasound was utilised more often for focused emergency echocardiography in resuscitation (FEER) exams and eFAST exams with the month of October having the highest number of POCUS exams performed (Figure 4 ). Positive findings were detected with POCUS exams (Table 1) The ultrasound machine was utilised more frequently during day-shift hours as opposed to after-hour use ( Figure 5 ). Eight percent of POCUS data had sonographer credentials saved ( Figure 6 ). The advantages of using POCUS in the ED make it a useful tool for resuscitative and diagnostic measures, procedure guidance, therapeutic and monitoring purposes. Although 12 emergency POCUS applications have been identified as essential for practice in the ED by the ACEP, proficiency and accreditation in the five level 1 emergency POCUS exams is the minimal recommended requirement by the College of Emergency Medicine of South Africa (CEMSA) for POCUS practice within our EDs. 18, 19 Our study showed that the scope of practice of POCUS by doctors working in the ED at GJGMRH included trauma and cardiac assessment, AAA and DVT screening, first trimester pregnancy assessment, urinary and biliary tract assessment, ocular and soft tissue applications, procedure guidance and post-intubation thoracic assessment. Focused emergency echocardiography in resuscitation and eFAST exams were the most frequent POCUS applications performed. A retrospective study by Stolz Pleural free-fluid 24 Pneumothorax 17 Abdominal free-fluid 14 Pericardial free-fluid 8 Flat IVC 77 22 Given the abrupt nature of trauma and medical presentations in the ED, delivery of emergency care takes precedence over saving ultrasound data. The ED at GJGMRH is one of the academic sites for rotating EM registrars. To date, the department has three emergency medicine specialists. This may have contributed to the peak in POCUS utility during day-shift hours noted in our study. Multiple factors may have played a role in the decline in ultrasound use in March including the declaration of a national state of disaster as a result of the COVID-19 pandemic. This study had several potential limitations. It was a retrospective review of medical records from a single source (ultrasound machine). Although the inclusion of the second ED ultrasound, patient folders and paper-based POCUS reports could have introduced conflicting data entries and data inconsistencies, exclusion of these data sources may have underrepresented the findings of POCUS utility. Incomplete data, missing data and sonographer credentials could have influenced the accuracy of our findings. The data abstractor was not blinded to the study objectives that may have biased some study variables. The results of our study showed that the ED at GJGMRH integrated POCUS core applications for various emergency care scenarios. Further studies are needed to assess POCUS use, barriers and challenges with adopting POCUS practice by associated acute care medical specialties such as paediatric and adult intensive care units. The high burden of injuries in South Africa Mortality and causes of death in South Africa: Findings from death notification Point-of-care ultrasound in Austere environments: A complete review of its utilization, pitfalls, and technique for common applications in Austere settings Integrating extended focused assessment with sonography for trauma (eFAST) in the initial assessment of severe trauma: Impact on the management of 756 patients Occult traumatic pneumothorax: Diagnostic accuracy of lung ultrasonography in the emergency department Focused cardiac ultrasound in the emergent setting: A consensus statement of the American society of echocardiography and American college of emergency physicians Ultrasound use during cardiopulmonary resuscitation is associated with delays in chest compressions Point-of-care ultrasound use in patients with cardiac arrest is associated prolonged cardiopulmonary resuscitation pauses: A prospective cohort study. Resuscitation American Heart Association guidelines update for cardiopulmonary resuscitation and emergency cardiovascular care Color doppler ultrasonography by emergency physicians for the diagnosis of acute deep venous thrombosis Real-time B-mode ultrasound in the ED saves time in the diagnosis of deep vein thrombosis (DVT) Prospective study of accuracy and outcome of emergency ultrasound for abdominal aortic aneurysm over two years Emergency physician ultrasonography for evaluating patients at risk for ectopic pregnancy: A meta-analysis Ultrasonography by emergency physicians in patients with suspected ureteral colic Bedside emergency department ultrasonography in the evaluation of ocular pathology Bedside ocular ultrasound in the emergency department Profile: Ilembe District Municipality (04/52): Ilembe District: Department of Cooperative Government and Traditional Affairs Emergency ultrasound imaging criteria compendium College of Emergency Medicine of South Africa Policy Document: Emergency ultrasound in South Africa Johannesburg: The College of Emergency Medicine: CEM (CMSA) Point-of-care ultrasound education for non-physician clinicians in a resource-limited emergency department Faculty opinions concerning ultrasound utilization in the emergency department Assessment of point-of-care ultrasound training for clinical educators in Malawi, Tanzania and Uganda The authors would like to thank the Department of Health and the staff at General Justice Gizenga Mpanza Regional Hospital for their contribution into making the research possible and Biostatistician, Fikile Nkwanyana (University of KwaZulu-Natal), for aiding in data analysis. This research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors. The data that support the findings of this study are available from the corresponding author, H.K., upon reasonable request. The views expressed in this article are those of the authors and are not representatives of the Department of Health, University of KwaZulu-Natal or General Justice Gizenga Mpanza Regional Hospital. The authors declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article.