key: cord-0813541-bqgm1e1x authors: Kushemererwa, G. E.; Kayongo, I.; Semanda, P.; Nansumba, H.; Namulindwa, C.; Tadeo, I.; Nyegenye, W.; Kiyaga, C.; Ogwok, P. A.; Nabadda, S.; Ssewanyana, I. title: Combination of Antibody based rapid diagnostic tests used in an algorithm may improve their performance in SARS CoV-2 diagnosis. date: 2020-06-29 journal: nan DOI: 10.1101/2020.06.26.20140806 sha: 35df69f596ddf30ebe35ee44f95f2e077efd071e doc_id: 813541 cord_uid: bqgm1e1x Background: Globally response to the SARS-CoV-2 pandemic is highly limited by diagnostic methods. Currently, World Health Organization (WHO) recommends the use of molecular assays for confirmation of SARS-CoV-2 infection which are highly expensive and require specialized laboratory equipment. This is a limitation in mass testing and in low resource settings. SARS CoV-2 IgG/IgM antibody tests have had poor diagnostic performance that do not guarantee their use in diagnostics. In this study we demonstrate a concept of using a combination of RDTs in an algorithm to improve their performance for diagnostics. Method: Eighty six (86) EDTA whole blood samples were collected from SARS-CoV-2 positive cases admitted at Masaka and Mbarara Regional Referral Hospitals in Uganda. These were categorized from day when confirmed positive as follows; category A (0-3 days, 10 samples), category B (4-7 days, 20 samples), Category C (8-17 days, 11 samples) and Category D (18-28 days, 20 samples). Plasma was prepared, transported to the testing laboratory and stored at -200C prior to testing. A total of 13 RDTS were tested following manufacturers instructions. Data was entered in Microsoft Excel exported to STATA for computation of sensitivity and specificity. We computed for all possible combinations of 2 of the 13 RDTS (13C2) that were evaluated in parallel algorithm. Results: The individual sensitives of the RDTs ranged between 74% and 18% and there was a general increasing trend across the categories with days since PCR confirmation. A total of 78 possible combinations of the RDTs to be used in parallel was computated. The combinations of the 2 RDTS improved the sensitivities to 90%. Discussion: We demonstrate that use of RDTs in combinations can improve their overall sensitivity. This approach when used on a wider range of combination of RDTs may yield combinations that can give sensitivities that are of diagnostics relevance in mass testing and low resource setting. sensitivity and specificity. We computed for all possible combinations of 2 of the 13 RDTS (13C 2) that were evaluated in parallel algorithm. The individual sensitives of the RDTs ranged between 74% and 18% and there was a general increasing trend across the categories with days since PCR confirmation. A total of 78 possible combinations of the RDTs to be used in parallel was computated. The combinations of the 2 RDTS improved the sensitivities to 90%. We demonstrate that use of RDTs in combinations can improve their overall sensitivity. This approach when used on a wider range of combination of RDTs may yield combinations that can give sensitivities that are of diagnostics relevance in mass testing and low resource setting. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted June 29, 2020. The Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a novel coronavirus that causes coronavirus disease 2019 (COVID-19), the respiratory illness responsible for the COVID-19 pandemic(1). SARS-CoV-2 specific antibodies are produced over days to weeks after infection with the virus. The strength of antibody response depends on several factors, including age, nutritional status, severity of disease, and certain medications or infections like HIV that suppress the immune system (2) . Antibody responses have been demonstrated in SARS-CoV-2 with a prevalence of 40% of patients in the first 7 days of illness, and then rapidly increased to 100.0%, 94.3% and 79.8% for Total Ab, IgM and IgG respectively since day 15 after onset(3). Evidence of early acquisition of SARS CoV-2 antibodies strengthen the idea of use of RDTs for mid, late, convalescent, and post-recovery phases of disease. Rapid diagnostic tests do not require any testing equipment, may be stored at room temperature are easy to operate and are cheap. They also have rapid screening time of approximately 10-15 minutes. These attributes make RDTS a very attractive for mass testing. Because of the poor performance of the currently available SARS COV-2 antibody RDTs, World Health Organization (WHO) recommends the use of RDT tests only in research and surveillance settings. In our study, we aimed at using 2 RDTS in a test algorithm to determine if it can improve their performance in terms of sensitivity and specificity. In a prospective study, a total of 86 samples were tested on each COVID -19 rapid diagnostic kit. Negative samples were retrieved from sample archives in the January 2018 inventory at the National Biorepository. Positive samples were obtained from confirmed positive patients by GeneXpert admitted at Masaka and Mbarara Regional Referral Hospitals and these were categorized from day when confirmed positive as follows; category A (0-3 days) 10 samples, category B (4-7 days) 20 samples, Category C (8-17 days) 11 samples and Category D (18-28 days) 20 samples. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 29, 2020. . https://doi.org/10.1101/2020.06.26.20140806 doi: medRxiv preprint Whole blood was collected in commercially available anti-coagulant EDTA tubes. The samples were transported to CPHL for testing as per CPHL standard operating procedures. Plasma was separated, aliquoted into 4 vials and stored according to CPHL standard operating procedures In this study we included 13 RDTs that were provided by different Laboratory suppliers who wanted to have their product evaluated .Testing of the Rapid Diagnostic test kits was carried out at the Central Public health laboratories (CPHL). This is a lateral flow immune chromatographic assay. All the 13 COVID-19 kits use anti human IgM antibody (test line IgM), anti-human IgG (test Line IgG) and IgG (control line) immobilized on a nitrocellulose strip. The burgundy colored conjugate pad contains colloidal gold conjugated to recombinant COVID-19 antigen conjugated with colloid gold (COVID-19 conjugate). When a specimen followed by a buffer is added, IgM and or IgG if present will bind to COVID-19 conjugates making antigen antibody complex. This complex migrates through nitrocellulose membrane by capillary action. A total of 13 rapid diagnostic kits were verified. 10 μ l aliquot of plasma was used on each of the rapid diagnostic test kits and results read between 10-20 minutes following each manufacturer's instructions on the Kit inserts. Results were recorded on a paper-based study record form (SRF), dated and initiated by a laboratory technologist and reviewed by another laboratory technologist All data was entered into Microsoft excel from the paper-based study record form (SRF). A 2 by 2 table was used to compute for sensitivity, specificity, negative and positive predictive values. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 29, 2020. . https://doi.org/10.1101/2020.06.26.20140806 doi: medRxiv preprint . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 29, 2020. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 29, 2020. Table 3 below . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 29, 2020. . https://doi.org/10.1101/2020.06.26.20140806 doi: medRxiv preprint 8 Table 3: Table showing computed sensitives from the 78 combinations 1 2 3 4 5 6 7 8 9 10 11 12 85 85 77 87 90 82 85 90 79 77 77 74 1 82 77 82 84 72 79 80 74 77 75 Two (2) Combinations of RDTs with sensitivities above 85% and 100% specificity tested in parallel were selected. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted June 29, 2020. . https://doi.org/10.1101/2020.06.26.20140806 doi: medRxiv preprint We observed the sensitivity of the individual kits ranging from 18%-74%. However the sensitivity improved with time since confirmed by PCR similar to other findings(3). When we used these kits in combinations of 2 the overall sensitivity improved up to 90% for the best combination. We provide evidence that use of RDTs in an algorithm may improve their performance in diagnosis for COVID-19. Further work is required to explore additional RDTS and combinations tested in parallel or series. The species Severe acute respiratory syndrome-related coronavirus : classifying 2019-nCoV and naming it SARS-CoV-2 Serology characteristics of SARS-CoV-2 infection since exposure and post symptom onset Antibody responses to SARS-CoV-2 in patients of novel coronavirus disease 2019 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity The copyright holder for this preprint this version posted June 29, 2020. . https://doi.org/10.1101/2020.06.26.20140806 doi: medRxiv preprint