key: cord-0811083-ayimdbp1 authors: Toschke, Yannic; Lusmoeller, Janet; Otte, Lars; Schmidt, Johann; Meyer, Svenja; Tessmer, Alexander; Brockmann, Christian; Ahuis, Milena; Hüer, Emma; Kirberger, Christian; Berben, Dirk title: Distributed LoRa based CO(2) monitoring network - A standalone open source system for contagion prevention by controlled ventilation date: 2022-01-10 journal: HardwareX DOI: 10.1016/j.ohx.2022.e00261 sha: 36ab3d75479b45f13d2f32f785903f321044ffbb doc_id: 811083 cord_uid: ayimdbp1 In the face of a global pandemic, such as that caused by the SARS-CoV-2 virus, the prevention of new infections is essential to stop the spread and ultimately return to normality. In addition to wearing masks and maintaining safe distances, regular ventilation in enclosed spaces where several people are gathered has proven to be an effective protective measure as advised by the World Health Organization. Additionally, as has been shown in a recent study of other airborne viruses, there is a strong correlation between the CO(2)level and aerosol content in a confined space under the assumption humans are the only CO(2)source. This can be exploited by means of a low-cost infrared CO(2)sensor to indirectly monitor the aerosol content and to provide targeted ventilation if predefined thresholds are exceeded. The distributed CO(2)monitoring network presented in this paper extends that idea and provides an inexpensive, comprehensive and modular monitoring network based on readily available components and 3D printing. By using a long-range communication link (LoRa) to centrally collect the real-time CO(2)concentration in a multitude of rooms, this network is particularly suitable for larger building complexes such as kindergartens, schools and universities without requiring partial or even full WLAN coverage. For some time now, the monitoring of indoor air quality by means of special monitoring systems has been gaining increasing popularity in society [1, 2] . Especially during the current SARS-CoV-2 pandemic, monitoring of indoor air quality plays an important role in minimizing the risk of infection with SARS-CoV-2 [3] . Particularly in schools where 20 to 30 people stay in one room for a prolonged period of time, it is important to monitor the indoor air quality. The main transmission of the SARS-CoV-2 virus is via respiratory inhalation of virus-containing particles [4] . These particles are emitted during any form of lung-ventilation, i.e. breathing, singing, coughing, etc.. Depending on the particle size, a distinction is made between larger droplets and smaller aerosols. While the larger droplets sink quickly to the ground, the smaller aerosols can also float in the air for a longer period of time and distribute themselves in enclosed spaces [5] . In one study, infectious particles could be detected for up to 3 hours in a room [4] . Therefore, especially at the present time, it is important to keep the concentration of aerosol particles in the air as low as possible to minimize the potential infection risk, as described by the Wells-Riley model of aerosol infection [6] . One way of achieving this goal is by sufficient ventilation. It has been shown that exhaled air comprises aerosols which may contain the SARS-CoV-2 virus in case of an infection [7, 8] . Thus, poorly ventilated or unventilated indoor environments significantly increase the likelihood of an airborne transmission of the SARS-CoV-2 virus. In addition to aerosols, humans exhale CO 2 with their respiration. The instantaneous CO 2 concentration can be used as a good proxy of aerosol particle concentration since the CO 2 concentration correlates with that of the aerosol particles assuming there is no other significant CO 2 source [9] [10] [11] [12] . It should be noted that the potential infection risk is a multi-parameter function, depending on many different aspects from which the cumulative CO 2 amount is only one. Yet, the cumulative CO 2 is still significant and directly linked to the more accessible instantaneous CO 2 concentration through the exposure time, i.e. a 6 hour school day. There are a variety of simplistic CO 2 monitoring devices on the market measuring the indoor CO 2 concentration. However, these CO 2 monitoring systems are very expensive, typically around 200 e [13] [14] [15] . A less expensive but yet more limited alternative is a commercially available CO 2 traffic light, which uses color coding to display the quality of the indoor air and thus, serves as an indicator for when manual ventilation needs to occur. A large number of CO 2 traffic lights have also recently emerged in the field of open-source solutions [16] [17] [18] [19] . These present a cost-effective alternative to the commercially available ones. However, these solutions are usually designed for monitoring a single room and lack the ability to monitor a complete building. Occasionally, the CO 2 traffic lights are networked via WLAN, which enables the monitoring of several rooms. In regard of the fact that not all schools have sufficient infrastructure, for example only 37 % of all teachers in Germany are satisfied with the quality of their WLAN [20] , a low-cost DIY CO 2 monitoring network with IoT connection was developed by students as part of the "5th. OpenPhotonik Pro Make@thon". Compared to the multitude of CO 2 traffic lights, this distributed CO 2 monitoring network offers a networking of the individual traffic lights by employing LoRa [21] . This means that schools with insufficient infrastructure can also install these traffic lights. The CO 2 traffic lights send their data to a central node via LoRa. This node is connected to a WLAN access point created by a Raspberry Pi. Using MQTT (a Message Queuing Telemetry Transport protocol), the measured CO 2 concentration from different rooms are graphically displayed on any WLAN-enabled terminal device. The classification of the indoor air quality is carried out according to the guidelines of the German Federal Environmental Agency [22] . The distributed CO 2 monitoring network was designed in a way that an additional CO 2 traffic light could always be added to increase the number of centrally monitored rooms. Furthermore, the individual CO 2 traffic light can be easily manufactured with the help of readily available components and additive manufacturing, e.g. 3D-printing. The hardware components used are a microcontroller (ESP32), an infrared CO 2 sensor, an OLED display, an RGB LED, a buzzer and a simple copper plate (as an capacitive touch switch). The CO 2 monitoring network presented here consists of individual CO 2 traffic lights which are interconnected via LoRa to a central Raspberry Pi B+ that consolidates the data and provides the browser accessible user-interface for easy data retrieval. The underlying concept is to use one of these CO 2 traffic lights in each room of interest in a larger building, e.g. a school, university or public institution, where the safe gathering of several people is to be supported by ventilation. Each of the CO 2 traffic lights has three distinct indicators to display the CO 2 level in a convenient way. The OLED display shows the current CO 2 level and room temperature in real time. The RGB led acts as a traffic light and signals via three colors (green, orange and red), whether ventilation is required or not. The additional built-in buzzer provides an acoustic signal corresponding to the traffic light colors. A copper plate acts as an capacitive touch button and is used to mute the acoustic signal when desired. This state automatically resets to the un-muted state once the predefined threshold is undercut. In addition, the real-time data as well as the temporal trend can be tracked through a browser by means of any WLAN capable device, e.g. a tablet, laptop or smartphone, via the access point of the Raspberry Pi. The great advantage is that the ventilation of an entire building can additionally be monitored centrally and, if necessary, logged. A connection station identical in construction to the CO 2 traffic lights but with a different software setup enables the real-time data to be transmitted via LoRa and forwarded directly to the Raspberry Pi via MQTT. This Pi potentially provides real-time data to the entire home network or can be set up to provide its own access point in case of unavailable WLAN. It can be considered as an important feature that no existing WLAN is necessary. If the Raspberry Pi is used as an access point, it provides the WLAN for the connection station and any central monitoring device (computer, laptop, tablet, etc.). A schematic of the above described interconnections is shown in Fig. 1 . The housing provided was kept simple and is equipped with corresponding mounting holes in the back for a wall-mounted installation. The housing is provided with ventilation cutouts at the position of the CO 2 sensor module (MH-Z19B) to to ensure optimal functionality. The micro-USB port of the ESP32 (DevKit C V4) is easily accessible from the outside. In this way future firmware updates can be easily deployed without the need to take the whole traffic light apart. Over-the-airupdates are a possibility for future improvements. There are basically two options for the power supply. The direct use of a USB power supply or the external use of any kind of power bank. Figure 1 : Shown is the concept of the CO 2 Monitor System. Each individual transmitter node is equipped with a display, a visual and an acoustic signal. The communication with the receiver node is done via LoRa. The receiver node additionally transmits the real-time data to a Raspberry Pi using the MQTT protocol over the Pi's own access point, thus allowing integration into other systems. The clear innovation of this CO 2 monitoring network compared to simple, independent CO 2 traffic lights is the use of LoRa for regular transmission of the measured values to a centrally monitored location. While simple CO 2 traffic lights only display the CO 2 concentration in real time and thus warn the user of rising CO 2 concentrations, there is no direct control according to the four-eyes principle. Although some models use MQTT via an existing WLAN, the latter is not met in many places. This applies not only to German schools but also to countries with a less developed infrastructure. Since the amount of data to be transmitted is small and the distances, for example in schools, can quickly become relatively large. The use of LoRa is an excellent solution at this point. With a range of several hundred meters, the CO 2 concentrations are transmitted at random intervals (approx. every 2.5 minutes with a random jitter of 60 seconds), as is usual with LoRa collision avoidance, which is perfectly sufficient to map the CO 2 concentration of a classroom over the course of a day. • The presented network centrally monitors the instantaneous CO 2 concentrations of a whole building and thus, allows to indirectly infer the aerosol load and hence the viral load in the assumed presence of an infected person. • The presented network can easily be expanded in a modular fashion across a multitude rooms. • The distributed devices directly provide optical and visual clues to ventilate when reaching predefined thresholds. • The presented network does not rely on an existing wireless local area network (WLAN) by using a long range communication link (LoRa). • The distributed devices are cheap to build, easy to install and configure. This chapter is subdivided into three sections, each providing information and focusing on a different aspect of the CO 2 monitoring network. First, a brief setup of the Raspberry Pi, second assembling a single CO 2 traffic light by means of its electrical wiring and third uploading and configuring necessary firmware to said traffic light. A rudimentary understanding of working with the ESP32, Raspberry Pi and Node-RED is presumed in the following. Extensive tutorials and instructions on the corresponding topics are available online within the DIY and Maker community [23] [24] [25] . (d) Install the Eclipse Mosquitto Broker (randomnerdtutorials.com) and Node-RED (nodered.org) on the Raspberry Pi. Make sure to enable the Node-RED service and configure autostart on boot. The default port is 1880 [24, 25] . (e) When configuring the Raspberry Pi as a WLAN access point make sure to write down the ssid and password along with the IP-address for the following setup of the individual CO 2 traffic lights. (f) To load and edit the provided Node-RED flow use any browser from your computer or laptop. The editor is available from 'http://IP-address:1880'. (g) The provided Node-RED flow CO2-Monitor-Station.json is designed to be loaded into the editor once for each CO 2 traffic light used. Afterwards the unique hexadecimal identifier needs to be configured accordingly to the ones used with each CO 2 traffic light. (h) Tip: The unique number used to identify each CO 2 traffic light is displayed as a decimal number each time you start or touch the copper, touch-sensitive switch. Ascending numbering is recommended, the use of unique numbers is mandatory. (i) After configuring the identifiers, the corresponding sources must be assigned to the display elements in the UI menu. After this minimal setup, the CO 2 concentrations of different rooms can be monitored through any device with a browser which is connected to the access point. In this section we focus on wiring and assembly of the CO2 traffic light. We provide some additional tips on the recommended 3D-printing and address aspects of planning. (a) Print the .stl files 'casing (front)' and 'casing (back)' using a FDM 3D-printer of your choice with 20% infill and 0.2 mm layer resolution. We recommend the use of PLA filament for ease of printing and good mechanical stability. Whilst printing the wiring can already be carried out. (b) The complete wiring diagram used is shown in Fig. 3 and will be broken down in separate steps below. The necessary layout for the components on the DOT PCB is shown in Fig. 4 . If no dimension is provided the the exact position does not have to be followed. (c) It is recommended to follow the layout to ensure that all cutouts of the housing are in the correct position. This ensures optimal visibility of the display and undisturbed ventilation of the CO 2 sensor. (d) Crucial components for the casing to fit are the 'CO2 Sensor' (MH-Z19B),'RGB led' (KY-016), the 'OLED display' (SSD1306) and the 'Buzzer' (TMB12A05). Once the DOT PCB is completely wired it is intended to be press-fitted into the casing. (e) To connect the 'CO2 Sensor' (MH-Z19B) wire GPIO32 with RX and GPIO33 with TX as shown in Fig. 5 . For the power supply, wire the 5V to VIN and GND to GND or a common ground. (f) To connect the 'OLED display' (SSD1306) wire GPIO21 with SDA and GPIO22 with SCL as shown in Fig. 6 . For the power supply, wire the 3V3 to VCC and GND to GND or a common ground. (g) To connect the 'LoRa module' (RFM9X) wire GPIO2 with DIO0, GPIO5 with CS, GPIO14 with RST, GPIO18 with SCK, GPIO19 with MISO and GPIO23 with MOSI as shown in Fig. 7 . For the power supply, wire the 3V3 to VIN and GND to GND or a common ground. (h) To connect the 'RGB led' (KY-016) wire GPIO4 with G, GPIO15 with B, GPIO15 with R and GND to GND or a common ground as shown in Fig. 8 . (i) To connect the 'Buzzer' (TMB12A05) wire GPIO27 with R1. Connect R1 directly to R2 and the base of the transistor. Wire the other end of R2 and the emitter to 3V3. Finally connect the collector with the 'Buzzer' and itself to GND. (j) To connect the 'Touch plate' wire GPIO13 directly to the copper plate after the cable has passed through the 'casing (front)'. To join the housing together afterwards, a cable length of 10 cm is recommended. (k) The copperplate which functions as a capacitive touch switch is intended to be glued down by some adhesive into the according slot of the 'casing (front)'. (l) Once every component is correctly wired press the assembled DOT PCB (Fig. 9 a) ) with a small amount of force into the 'casing (back)' (Fig. 9 b) ). The dimensions are designed to be press-fitted. In the case of too wide tolerances, i.e. the DOT PCB has slack inside the housing, apply some hot-glue to keep the DOT PCB in place within 'casing (back)'. (m) To assemble the whole CO 2 traffic light, press the 'casing (front)' (Fig. 9 c) ) directly onto the prior assembled 'casing (back)'. The dimensions of both parts are designed to be press-fitted. Should the two casing parts exhibit too wide tolerances, one can easily apply some electricians tape to fill the gap and thus insure a removable press-fit. The utilization of super-glue is fine (avoid contaminating display or sensor), however, disassembly of a glued casing is most likely destructive and will require printing a new casing. The final assembly is shown in Fig. 9 d) . This section covers the upload of the firmware to the ESP32 and the required settings in the software file CO2-Monitor v7f.ino. A basic distinction is made between the regular CO 2 traffic light and the connection station, a software modification of the CO 2 traffic light, which additionally transmits the data collected from every other traffic light via LoRa to the Raspberry Pi via MQTT. (a) The software designated for the ESP32 is the CO2-Monitor v7f.ino. To upload this software the integrated development environment of Arduino is used (Arduino IDE). (b) The first step is to add the ESP32 as a board. In your Arduino IDE, navigate to File → Preferences and add https://dl.espressif.com/dl/package esp32 index.json into the 'Additional Board Manager URLs' field. (c) The requirements.txt file contains an overview of the required libraries, which can be downloaded either directly from the repository or from the Arduino IDE package manager. (d) Immediately before uploading the software to the ESP32, the correct board (ESP32 Dev Module) must be selected under Tools and configured if necessary. (e) The following constants and variables must be set before the upload according to the desired configuration. • NUM is a unique hexadecimal number between 0 and 255 (0x00 to 0xFF) which must be different for each CO 2 traffic light. • SETUP STARTUP TIME is 3 minutes if a CO 2 sensor is installed. • SENSOR MODULE is true (CO 2 traffic light) or false (only connection station without CO 2 sensor) • MQTT MODULE is false (CO 2 traffic light) or true (connection station) • PERIPHERY MODULE is true (CO 2 traffic light) or false (without the OLED display etc.) • int stage1 = 800; lower CO 2 threshold in ppm int stage2 = 1000; upper CO 2 threshold in ppm • const char* ssid = "RaspiAP "; your ssid of the Raspberry Pi AP • const char* password = "12345678 "; your password of the Raspberry Pi AP, change at your earliest convenience, but do note it somewhere • const char* mqtt server = "192.168.178.11 "; your IP of the Node-RED server change to your liking (f) After all constants and variables have been set to the desired value, the CO2-Monitor v7f.ino file can be uploaded to the ESP32. The choice of the MH-Z19B CO 2 sensor is due to its good availability at the time of writing. In addition to a sufficient measuring range from 0 ppm to 5000 ppm, this particular sensor has a selfcalibration function. It should be noted that there are also cheaper air quality sensors, but these are usually not CO 2 specific, resulting in potentially faulty readings due to cross-sensitivity to other gases. Another positive point is the easy integration with the Arduino. Possible alternatives are the somewhat more expensive SCD30 CO 2 sensor from Sensirion or the direct successor model, the MH-Z19C. The used ESP32 NodeMCU DevKit C V4 was chosen especially because of its programmability in Arduino and its integrated WLAN and Bluetooth functions. Compared to its direct predecessor, the ESP8266, the ESP32 has a 240 MHz dual core processor and a 4 Mbyte flash memory, making it the modern and more powerful choice. This together results in a large and helpful online community, making development very beginner-friendly. Again, it should be noted that the specific choice of this ESP32 module is related to availability at the time of writing. Alternatively, any other available ESP32 module can be used. Only the software has to be adapted accordingly and sometimes not even that, if a pin-compatible replacement has been chosen. The RFM9X LoRa Packet Radio, along with the CO 2 sensor used, is at the heart of the hardware presented here. By additionally using a Raspberry PI as WLAN access point and MQTT broker, the RFM9X module allows to monitor entire building complexes and facilities centrally via LoRa at 868 MHz. The obvious advantage is the low cost (approx. 90 e) of the individual CO 2 traffic lights without requiring an already existing or area-wide WLAN. In order to remain compliant with the legal framework regarding the bandwidth used and to avoid possible transmission collisions, the measured values are transmitted approx. every 2.5 minutes with a random jitter of 60 seconds. The following instructions deal with the operation of the distributed CO 2 monitoring network. They cover the operation of the individual CO 2 traffic lights as well as the entire network. The installation as described in chapter 5 is mandatory and presumed. • Place or mount the CO 2 traffic light in a location of your choice using the integrated keyhole mounting. Keep in mind that the positioning has an influence on the measured CO 2 concentration and it is therefore recommended to mount the CO 2 traffic light at chest/head height. • Connect the CO 2 traffic light using a micro USB cable and an appropriate USB power adapter (5 V, 1 A) with the power outlet. Alternatively, a power bank can be employed for mobile use. The consumption of the CO 2 traffic light is about 550 mW. • Immediately after start-up, the CO 2 traffic light displays its previously set unique number NUM as 'Sense NUM' followed by the message 'Sensor Warm-Up'. • The warm-up time of the sensor is 3 minutes according to the manufacturer's specifications and can be edited in the code. After this time, the CO 2 traffic light is ready for use and displays the CO 2 content in ppm and the room temperature in°C. • The RGB LED indicates an exceeding of the previously set thresholds by a change in color from green (everything is alright) to orange (it should be ventilated soon) and finally to red (ventilation is now required). At the same time the respective thresholds are linked to an acoustic warning signal. • To mute the acoustic warning signal of the CO 2 traffic light, touch the copper, touch-sensitive switch. The muting of acoustic warning signals is toggled back to active by the CO 2 reading falling below the predetermined threshold. • Transmission of the current CO 2 concentration via LoRa to the connection station is done automatically and does not require any further steps besides the correct configuration of the CO 2 traffic light. • In order to use the LoRa based CO 2 monitoring system, one of the CO 2 traffic lights must be set up as a connection station as described in chapter 5. The basic concept is to use exactly one connection station in combination with a Raspberry Pi based access point and any number of additional ordinary CO 2 traffic lights. • The connection station must first be installed in the WLAN range of the Raspberry Pi access point used. The CO 2 traffic lights connected via LoRa have a range of several hundred meters due to the use of typical radio frequencies. The absolute range depends primarily on the combination of distance and obstacles (walls/buildings) and cannot be generalized. • To use the monitoring capabilities an additional device like a tablet or laptop is advised. With said device connect via WLAN to the access point of the Raspberry Pi and navigate to the browser-based Node-RED UI ('http://IP-address:1880/ui'). • A brief explanation on the setup is provided within section 5.1. The above used IP-address is the one of the Raspberry Pi running the Node-RED service. • From the the browser-based Node-RED UI the real-time CO 2 concentration, room temperature and received signal strength indicator (RSSI) can be monitored as shown in Fig. 10 . The data gets updated approximately every 2.5 minutes. Figure 10 : The presented CO 2 monitor allows simultaneous monitoring of several rooms at the same time as shown in the screenshot above. Here the CO 2 concentration, the room temperature and the received signal strength indicator of the LoRa modul are displayed i.e. for system debugging during installation. In this chapter, two types of measurements are presented to validate the individual CO 2 traffic light and the entire monitoring network from a practical point of view. In order to reliably comply with the set concentration thresholds, one traffic light was examined with regard to its CO 2 concentration measurement capability. Furthermore, the validation of the hardware regarding its everyday use takes place in a volunteering school. For validation of the CO 2 concentration measurements, four predefined gas mixtures (1000 ppm, 2000 ppm, 3000 ppm and 4000 ppm) were prepared and used to measure different concentration levels by means of an exemplary CO 2 traffic light. The measurements were carried out with the kind support of 'ecom GmbH'. The process of producing the gas mixtures is described in the following paragraph. For mixing, a bottle of 20 % CO 2 ('Westfalen AG', type: carbon dioxide 3.0) and a bottle of pure N 2 ('Westfalen AG', type: nitrogen 5.0) are used. Each one of the bottles is connected to a separate gas flow controller (CO 2 , 'Vögtlin Instruments GmbH', type: GSC-B9TS-DD23 calibrated to 2 bar; N 2 , 'Vögtlin Instruments GmbH', type: GSC-B4TS-DD23 calibrated to 3 bar) and the corresponding normal flow rates (CO 2 , 2.0 l/min; N 2 , 0.4 l/min) are set. A commercial gas bag ('Westfalen AG', type: Alumini 1 (15 l)) is used as a vessel for mixing, which is completely evacuated before the mixing process. Then, using a stopwatch and the gas meter, the two gases are filled one after the other into the gas sack by means of a hose with a quick-release coupling (PFA 4x6 mm, various Rectus products with material 1.4305). When the previously calculated duration is reached and For the validation process, the warm-up phase of the CO 2 traffic light takes place directly at the open window. Afterwards, the CO 2 traffic light is placed in an airtight lockable box (approx. volume: 2 l) with a fixed inlet and outlet (6 mm holes). To power the hardware a power bank is used. The previously filled gas bag is weighted with a simple 1 kg weight to create a constant pressure. The gas bag is then connected to the box with the CO 2 traffic light by means of a hose with a quickrelease coupling. To maintain a constant gas flow, the weight must be repositioned approximately every 5 minutes. This ensures that the box is continuously purged with the previously prepared gas mixture. After approximately 25 minutes, the final static value is read from the CO 2 traffic light. The results of the validation measurement are shown in Fig. 11 . Within the limits of their errors, the measurements show an excellent agreement between the CO 2 concentration measured by the CO 2 traffic light (MH-Z19B) and the beforehand prepared CO 2 concentration of the gas mixture. We conclude that the CO 2 traffic light is suitable to provide accurate CO 2 -measurements and thus valuable information of the viral load within its error margin. In addition, the predefined threshold of 800 ppm is a useful first indicator of when ventilation is recommended. According to the manufacturer's data sheet, the measurement error at a read concentration of 1000 ppm is ±100 ppm. Accordingly, the upper threshold of 1000 ppm is undercut with a high probability assuring maximal safety. For the validation of the CO 2 monitoring network from a practical point of view (central monitoring, LoRa functionality and deployment under real conditions), the system presented in this paper was deployed in the 'Evangelisches Gymnasium Nordhorn' and subjected to a field test. For this purpose, the system was used in a total of two classrooms as shown in Fig. 12 in addition to the locally applicable regulations for ventilation. The classrooms were ventilated approximately every 20 minutes for a period of 5 minutes (according to the specifications of the head of school), irrespective of the actual CO 2 concentration. If the previously set threshold of 800 ppm is exceeded, additional ventilation takes place. Figure 13 shows the measured course of CO 2 concentration over The gathered data was sent via LoRa from the classroom to the connection station approximately every 2.5 minutes (including a random delay for collision avoidance) and stored via Node-RED. The course of the data suggests that the selected sampling rate is sufficient to represent the rather slow variation in CO 2 concentration with sufficient detail. It can be clearly seen that after a short time delay after opening the windows for ventilation, the CO 2 concentration decreases. This delay is most likely due to the initial mixing of the stale and fresh air, so that the CO 2 concentration does not drop instantaneously when opening the windows. Besides prolonged ventilation periods like from 11:15 a.m. till 12:00 a.m. due to high temperatures above 31.0 • C a direct decrease in concentration is achievable when necessary. It should be emphasized at this point that at two points in time, despite the ventilation regulations already in place, the threshold of 1000 ppm was exceeded, which underlines the usefulness of the presented CO 2 monitoring network. To validate the CO 2 monitoring network's LoRa range, the system presented in this paper was tested thoroughly at the 'Evangelisches Gymnasium Nordhorn'. In particular, the potential range of this system was analyzed in two scenarios, one indoors and one outdoors. It is important to emphasize that accurate validation of LoRa range depends on a variety of different parameters, such as distance, shielding by walls and ceilings or background noise. Since these parameters can only be controlled to a limited extent, the validation performed serves more as a proof of concept instead of an exact measurement of the achievable range. For the indoor validation the CO 2 traffic light used as receiver (connection station) was placed at a fixed position inside the school's building while the transmitting CO 2 traffic light was moved to Figure 13 : Validation of the CO 2 monitoring network through a field test in a school. Shown is the measured course of CO 2 concentration over 6 school hours (07:45-12:15). A gray shading corresponds to no ventilation, during a blue one there is ventilation and in the dashed areas the classroom was empty. A ventilation-dependent decrease in CO 2 concentration with an expected delay after opening the windows can be clearly seen. ten different rooms and locations for validation of the received signal strength indicator (RSSI). Figure 14 shows a sketched layout of the school building. The red dot represents the position of the fixed receiver (connection station). The blue dots numbered from 0 to 9 show the relative positions of the transmitter. Differences in height are omitted for sake of simplicity. The measured RSSI, Table 2 using a sketched layout of the school building. The red dot represents the position of the fixed receiver (connection station). The numbered blue dots show the relative positions of the transmitter (CO 2 traffic light). Distances used are estimated and differences in height are not shown in this sketch. including a short description of involved obstructions and an estimate of the distance are shown in Table 2 . The data obtained clearly indicates a sufficient signal strength for an obstruction of up to five walls (#5) at a distance of approx. 43 m. Only through eight walls (#6) at a distance of approx. 57 m no signal was received, which does not represent the most realistic use case since the CO 2 traffic light used as receiver would be planted in a more central position. Furthermore, Table 3 shows the measured RSSI in an outdoor scenario from 100 m to 1000 m with an unobstructed view realized on a field trail. This data also indicates a sufficient signal strength even at the maximal distance of 1000 m. Any further distances were neglected due to the unrealistic use case. Both measurements combined conclude, that the number of obstructions play by far a more crucial role as the absolute distance and the use of one CO 2 traffic light configured as connection station is sufficient in most cases. This research is part of the project Optocubes * and was funded by the German Federal Ministry of Education and Research (BMBF) within the funding program "Photonics Research Germany" with contract number 13N15229 and 13N15230. The authors are responsible for the contents of this publication. Indoor Air Quality Assessment Using a CO2 Monitoring System Based on Internet of Things Testing mobile air purifiers in a school classroom: Reducing the airborne transmission risk for SARS-CoV-2 World Health Organization, Roadmap to improve and ensure good indoor ventilation in the context of COVID-19, World Health Organization SARS-CoV-2 -Epidemiologischer Steckbrief zu SARS-CoV-2 und COVID-19 Clinical infectious diseases : an official publication of the Infectious Diseases Society of America Airborne Spread of Measles in a Suburban Elementary School Aerosol transmission of SARS-CoV-2? Evidence, prevention and control Aerosol and surface stability of HCoV-19 (SARS-CoV-2) compared to SARS-CoV-1, medRxiv Risk assessment of aerosols loaded with virus based on CO2-concentration Effects of ventilation on the indoor spread of COVID-19 Exhaled CO2 as a COVID-19 Infection Risk Proxy for Different Indoor Environments and Activities Mitigating aerosol infection risk in school buildings: the role of natural ventilation, volume, occupancy and CO2 monitoring Mobile CO2-Ampel zur flexiblen direkten Wandmontage Conny -CO 2 Ampel ® Design and Development of a Low-Cost, Portable Monitoring Device for Indoor Environment Quality Real-Time Monitoring of Indoor Air Quality with Internet of Things-Based E-Nose, Applied Sciences Development of an Arduino-based CO2 Monitoring Device From Do-It-Yourself (DIY) to Do-It-Together (DIT): Reflections on designing a citizen-driven air quality monitoring framework in Taiwan Monitor Digitale Bildung -Die Hochschulen im digitalen Zeitalter Gesundheitliche Bewertung von Kohlendioxid in der Innenraumluft The Raspberry Pi Foundation Random Nerd Tutorials helps makers, hobbyists, and engineers build electronics projects Node-RED is an open source flow-based programming tool The authors would like to thank ecom GmbH and Tom Maschin for the support in the chapter 'validation and characterization' and for providing the measuring equipment. The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analysis, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results. * https://www.photonikforschung.de/projekte/open-innovation/projekt/optocubes.html