key: cord-0810664-yfn0vnde authors: Liu, Chong; Shi, Qingxin; Peng, Mingfei; Lu, Ruyue; Li, Haohao; Cai, Yingying; Chen, Jiaxi; Xu, Jiaqin; Shen, Bo title: Evaluation of droplet digital PCR for quantification of SARS-CoV-2 Virus in discharged COVID-19 patients date: 2020-11-01 journal: Aging (Albany NY) DOI: 10.18632/aging.104020 sha: 0ee13ba60639aac6a99034ace646d492192488bc doc_id: 810664 cord_uid: yfn0vnde The worldwide severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) outbreak has led to the rapid spread of coronavirus disease (COVID-19). The quantitative real time PCR (qPCR) is widely used as the gold standard for clinical detection of SARS-CoV-2. However, more and more infected patients are relapsing after discharge, which suggests qPCR may fail to detect the virus in some cases. In this study, we selected 74 clinical samples from 43 recovering inpatients for qPCR and Droplet Digital PCR (ddPCR) synchronous blind detection, and established a cutoff value for ddPCR diagnosis of COVID-19. The results showed that at a cutoff value of 0.04 copies/μL, the ddPCR sensitivity and specificity are 97.6% and 100%, respectively. In addition, we also analyzed 18 retained samples from 9 discharged patients who relapsed. Although qPCR showed all 18 samples to be negative, ddPCR showed 12 to be positive, and there was only one patient with two negative samples; the other eight patients had at least one positive sample. These results indicate that ddPCR could significantly improve the accuracy of COVID-19 diagnosis, especially for discharged patients with a low viral load, and help to reduce misdiagnosis during recovery. After the outbreak of the novel coronavirus disease (COVID-19), it quickly spread throughout China and to more than 180 other countries, and the World Health Organization (WHO) declared it to be a pandemic [1, 2] . Although quantitative real-time PCR (qPCR) detection of nucleic acids from the virus has become a standard method for diagnosis of SARS-CoV-2 infection, this approach is limited by an unsatisfactory amplification curve, which can lead to the occurrence of false negatives [3] [4] [5] . The high false negative rate and the lack of availability of qPCR assays for discharged patients during the outbreak restricted prompt diagnosis of infected patients [6, 7] . In addition, the qPCR method does not provide information about viral load, which would enable evaluation of disease progression and prognosis. Consequently, to prevent SARS-CoV-2 transmission and ensure timely treatment of infected patients, there is an urgent need for an accurate detection method to quickly identify infected patients and asymptomatic carriers [8] . Several studies have shown that droplet digital PCR (ddPCR) has the advantages of absolute quantification and greater sensitivity for virus detection than qPCR. In the present study, we used ddPCR to enable highly sensitive and quantitative detection of SARS-CoV-2 in discharged patients with low viral loads, which could prevent false negatives during clinical diagnosis, thereby reducing a potential risk of viral transmission. Through assays of 74 clinical samples, we were able to establish a SARS-CoV-2 cutoff value of ddPCR, AGING which was then used to evaluate retained samples from discharged COVID-19 patients. Seventy-four clinical samples collected from 43 recovering COVID-19 patients were tested using both qPCR and ddPCR. The samples including 36 feces samples, 36 sputum samples, and 2 throat swabs. Using qPCR, we found that 42 samples were positive and 32 were negative (Supplementary Table 1) , and with ddPCR we found that 41 samples were positive and 33 samples were negative (Table 1 ). There were 16 samples with inconsistent results between the ddPCR and qPCR, which were considered positive, since all samples were from confirmed COVID-19 patients. ddPCR had a significantly higher positive detection rate than qPCR (55.41% vs. 36.49%; P<0.05, Chi square test). For 16 samples from COVID-19 patients, the results of SARS-CoV-2 virus detection with qPCR and ddPCR were not in agreement (Supplementary Table 1 ). After sample grouping, a receiver operating characteristic (ROC) curve was constructed for ddPCR ( Figure 1 ). The area under the curve (AUC) was 0.988 (P<0.001), which indicates that the accuracy of ddPCR is very high. After selecting the point corresponding to the maximum value of the Youden index (Sensitivity value + Specificity -1) as the ddPCR cutoff value (0.04 copies/μL), the sensitivity was 97.6%, and the specificity was 100%, indicating moderate sensitivity and high specificity for SARS-CoV-2. The above results showed that ddPCR was better than qPCR for detecting SARS-CoV-2 in samples with a low viral load, especially in discharged patients. Therefore, We analyzed 18 retained samples from 9 discharged patients who had relapsed and were again testing positive. According to the qPCR results, all 18 retained samples were negative. However, ddPCR showed that 12 of the samples were positive, while only 6 were negative ( Table 2) . There was only one patient with two negative samples; the other eight patients had at least one positive sample (Table 2 ). This result indicates that ddPCR significantly improved diagnostic accuracy, especially for samples with a low viral load in supposedly recovered patients. The current method used for detection of SARS-CoV-2 involves a qPCR-based technique, which identifies the viral RNA when present in sufficient quantity [9] . Unfortunately, false negatives can occur, and the resultant failure to quarantine those infected patient would be a major setback to containing viral transmission [10] . When we compared the performances of qPCR and ddPCR in 74 samples from 43 confirmed patients, we found that qPCR and ddPCR gave comparable results with samples containing high viral loads, but ddPCR performed significantly better with samples containing a low viral load. Notably, the background readouts with ddPCR were lower, which could effectively reduce the incidence of false positives. Consequently, the ddPCR technique would likely be a better method for quantification of SARS-CoV-2 virus in discharged patients with a low viral load, since it shows superior precision and sensitivity for detection of low concentrations of target RNA [11, 12] . Yu et al. have taken a first step toward use of ddPCR for quantitative detection and viral load analysis of SARS-CoV-2 in infected patients [13] . Using ddPCR in the present study, we obtained 41 positives among our 74 samples, and ddPCR showed outstanding sensitivity and specificity for SARS-CoV-2. These results thus suggest that for patients with a low viral load, SARS-CoV-2 virus amplification with ddPCR is technically feasible and could potentially be used as a standard method for dynamic detection of viral load. More and more patients are showing relapse positivity after discharge, while numerous individuals test negative for COVID-19 many times before they test positive. This suggests that qPCR is failing to detect virus in some cases [14, 15] . According to the COVID-19 diagnosis and treatment plan used in China, patients reach the discharge criterion with at least two negative RNA tests. However, when we tested 18 retained samples from 9 discharged patients who were again testing positive, we found that only one patient with two negative samples; the other eight patients had least one positive sample. As time goes on, greater numbers of patients will enter the recovery stage and will be deemed ready for discharge. As a result, testing samples with low viral loads will become more frequent. We suggest that ddPCR should be used as a reference standard for discharge diagnosis of patients recovering from COVID-19. Moreover, ddPCR maybe used to monitor changes in viral load and to check the close contacts of patients who may be low virus carriers. Due to its small sample size, our study has two limitations. First, we did not analyze the relationship between viral load and COVID-19 severity at different AGING Positive 26 1 27 Negative 15 32 47 Total 41 33 74 stages. Second, there was little analysis of the low viral load in discharged patients. In the future, we will investigate whether ddPCR can be used to dynamically monitor SARS-CoV-2 viral load in patients. As shown in Figure 2 , between February 29 and March 6, 2020, we collected 74 clinical samples from 43 recovering COVID-19 patients. These included 36 feces samples, 36 sputum samples, and 2 throat swabs. In addition, we selected 9 patients, who relapsed and were again positive for viral RNA after discharge. The 18 retained samples collected from these 9 patients before their first discharge included 3 sputum samples and 15 throat swabs. All 52 patients gave informed consent and agreed to participate in this study. The patients included 27 (51.9%) males and 25 (48.1%) females with a median age of 51 years (range: 41 to 56 years). Among the participants, hypertension was found in 3 patients (5.8%), diabetes in 2 patients (3.8%), hyperlipidemia in 1 patient (1.9%), digestive diseases in 3 patients (5.8%), chronic liver disease in 4 patients (7.7%), chronic lung disease in 1 patient (1.9%), and a tumor in 2 patients (3.8%). In addition, 5 patients had undergone surgery (9.6%). Sputum was fluidized with a digestant, then centrifuged for 15 min at 14,000 rpm. Stool samples were homogenized in physiological saline, vortexed for 15 min, and centrifuged for 15 min at 10,000 rpm. Throat swabs were soaked in physiological saline and centrifuged for 15 min at 10,000 rpm. Following centrifugation, total RNA was extracted from the supernatants with a Nucleic Acid Extraction Kit, and processed according to the manufacturer's instructions (Shanghai ZJ Bio-Tech Co., Ltd). qPCR detection was carried out by using a Novel Coronavirus Real Time qPCR Kit, and processed according to the manufacturer's instructions (Shanghai ZJ Bio-Tech Co., Ltd). Primers and probes targeting the N gene of SARS-CoV-2 were designed by Primer Express software, while internal control (IC) gene was used to ensure the reagents work well. The sequences of primers and probes are shown in Table 3 . The 74 clinical samples were assayed using qPCR and ddPCR synchronously. After comparing the qualitative results of ddPCR and qPCR, samples for which the results differed between the two methods were classified as positive, since all samples were from confirmed COVID-19 patients. Other samples were classified based on consistent ddPCR and qPCR results. After sample grouping, a cutoff value for the ddPCR was confirmed using ROC curve analysis. Eighteen retained samples collected from 9 relapsed COVID-19 patients before they were first discharged were assayed using ddPCR and analyzed based on the ddPCR cutoff. The investigators performing the assays were blinded to the patient information. All statistical analyses were performed using SPSS 13.0 software. The protocol was approved by the Ethics Committee of the Zhejiang Taizhou hospital affiliated to Wenzhou Medical University. Written informed consent was obtained from all participants. Neutrophil-to-lymphocyte ratio as an independent risk factor for mortality in hospitalized patients with COVID-19 Chest CT for typical coronavirus disease 2019 (COVID-19) pneumonia: relationship to negative RT-PCR testing CT imaging changes of corona virus disease 2019(COVID-19): a multicenter study in Southwest China Characteristics of and important lessons from the coronavirus disease 2019 (COVID-19) outbreak in China: summary of a report of 72 314 cases from the Chinese center for disease control and prevention Development of digital PCR molecular tests for clinical practice: principles, practical implementation and recommendations Current, emerging, and future applications of digital PCR in non-invasive prenatal diagnosis DNA methylation analysis using droplet digital PCR Digital PCR provides sensitive and absolute calibration for high throughput sequencing Absolute quantification by droplet digital PCR versus analog realtime PCR Why is it difficult to accurately predict the COVID-19 epidemic? Investigating the cases of novel coronavirus disease (COVID-19) in China using dynamic statistical techniques COVID-19 Pandemic: Experiences in China and Implications for its Prevention and Treatment Worldwide ddPCR: a more accurate tool for SARS-CoV-2 detection in low viral load specimens Applications of Digital PCR for Clinical Microbiology Evaluation of digital PCR for absolute RNA quantification Supplementary Table 1. Detection of ddPCR in 74 clinical samples from recovering COVID-19 patients Haitao Zhu, De Ye, Xiaohui Song, Xuxin Li, Pilot Gene Technologies (Hangzhou) Co., Ltd. The authors declare that they have no conflicts of interest that could have appeared to influence the work reported in this paper. This project was supported by grants from the National Natural Science Youth Foundation of China (No. 81802078) and the Science and Technology Project of Taizhou (20ywa10).