key: cord-0810351-wvj0xhvt authors: AR GOUILH, M.; CASSIER, R.; MAILLE, E.; Schanen, C.; ROCQUE, L.-M.; VABRET, A. title: An easy, reliable and rapid SARS-CoV2 RT-LAMP based test for Point-of-Care and diagnostic lab date: 2020-09-25 journal: nan DOI: 10.1101/2020.09.25.20200956 sha: e33791175d69e3d900ed203acdb00327a1fc96f3 doc_id: 810351 cord_uid: wvj0xhvt This study presents and evaluates a rapid and all-in-one SARS-CoV-2 RT-LAMP based molecular detection system, including RNA extraction or not, for point-of-care or massive testing of naso-pharyngeal swabs. The point-of-care format uses LoopX(C), a small portative device ensuring optimal LAMP reaction and automated reading with 95.2% and 95.5% sensitivity and specificity respectively. This system might also be useful for testing other sample types such as saliva. RT-LAMP (Reverse-Transcription and Loop-mediated isothermal AMPlification) might advantageously increase testing efficiency as it allows all-in-one rapid test including RNA reverse transcription and DNA amplification without temperature cycles requirement. LAMP does not even require complex devices and laboratory infrastructures, RT-LAMP can use low-cost and mobile equipment already available in most molecular diagnostic laboratories and utilises the inhibitors tolerant Bst polymerase [1] . These traits make LAMP useful in field detection assays [2] [3] [4] [5] [6] . The use of LAMP in detection system has been explored for numerous micro-organisms and epidemic pathogen (Zika-virus, Ebolavirus, Malaria) [7] several of which validated by WHO [8] , an FAO [2, 9] . SARS-CoV2 RT-LAMP tests were previously developed but to our knowledge, none of them propose a direct-from-swab, on field and all-in-one analytical solution such as ours [10] [11] [12] [13] [14] [15] . We developed a specific RT-LAMP in dual format for the detection of SARS-CoV-2. The first one, named LoopXlab COVID-19 operates without extraction in conventional thermalcyclers (using 96 wells plates or 8 wells strips). The second one, named LoopXplore COVID-19, is designed for Point of Care (without extraction) and runs in the LoopX device (in 1.5 ml µtube). The objective of the study was to evaluate the performance of our two detection methods. Nasopharyngeal samples (n=348) from patients with medical prescription were collected for virological diagnostic at the virology unit of CAEN University Hospital Center during April, May and June 2020. All samples were submitted to routine molecular diagnosis first and declared to be used in research. Two available RT-qPCR systems were compared to our tests. The PCR developed by the french national reference center for respiratory viruses (targeting RdRp with IP2 / IP4 systems, and E gene) and a commercial multiplex real time RT-qPCR targeting the RdRp, E and N viral genes (Allplex 2019-nCov assay kit, Seegene, Korea). RT-qPCR assays were performed on Lighcycler 480 (Roche) and CFX (Biorad), two broadly available thermalcyclers. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted September 25, 2020. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted September 25, 2020. . https://doi.org/10.1101/2020.09.25.20200956 doi: medRxiv preprint The linearity for both RT-LAMP and RT-qPCR gave similar results (Figure 2 ). The limit of detection was calculated by limiting dilution. For each dilution point, RT-LAMP and RT-qPCR assays were tested in triplicates. For the latest dilutions (<100 RNA copies), the RT-qPCR Ct (Cycle threshold) exceeded 35. The LoopXplore test (POC) and the RT-qPCR gave similar results. In addition, Linearity and limit of detection were tested on CFX (Biorad), Lightcycler 480 (Roche), MIC (Biomolecular systems) and RotorGene (Qiagen) machines. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted September 25, 2020. . https://doi.org/10.1101/2020.09.25.20200956 doi: medRxiv preprint LoopXlab and the LoopXplore POC tests were negative for a total of 52 respiratory samples positives for non-SARS-CoV2 coronaviruses, Rhino/Enteroviruses, Influenzavirus, RSV and other respiratory pathogens ( Table 1 ). The validation consisted in testing 177 RNA extracts to optimize the RT-LAMP step and 171 crude samples without extraction to measure potential inhibition. Most widely used transport media were tested (Table 2) . Media containing significant amount of EDTA or Ethanol (known inhibitors for the LAMP reaction) inhibit the reaction and cannot be used in our tests without extraction ( Table 2 ). All samples were analyzed twice by RT-qPCR and both RT-LAMP technics (LoopXplore in LoopX and LoopXlab in thermalcycler). RT-LAMP methods have similar sensitivity and specificity (LoopXlab: 98.6% and 91.5%, LoopXplore: 95.2% and 95.5%, respectively) Only one sample was not detected by loopXlab (RT-qPCR CT value of 32 ) and LoopXplore (CT >35)( Table 3 ). is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted September 25, 2020. . https://doi.org/10.1101/2020.09.25.20200956 doi: medRxiv preprint Table 2 : List of transport media tested with LoopXlab technology. "Compatible media" indicates the absence of inhibition. "Not optimal" indicates that inhibition is rarely observed. "Not compatible" indicates that inhibition is systematically observed. For media not listed here, inhibition controls are recommended. Table 3 : Sensitivity and specificity for LoopXlab and LoopXplore with and without extraction. qRT-PCR ct values were given by the IP2-IP4 system from national reference lab. Physiological water -Compatible The funders has no role in the design of the study. This study has been funded by the Agence de l'Innovation de Défense" (French Defence Innovation Agency) and the "DGA Maitrise NRBC" (Armament General Directorate CBRN Defence Center), CHU de Caen and Loop Dee Science. 7 . CC-BY-NC 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted September 25, 2020. . https://doi.org/10.1101/2020.09.25.20200956 doi: medRxiv preprint . CC-BY-NC 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted September 25, 2020. . https://doi.org/10.1101/2020.09.25.20200956 doi: medRxiv preprint Rapid and in-situ detection of fecal indicator bacteria in water using simple DNA extraction and portable loopmediated isothermal amplification (LAMP) PCR methods Development of LAMP and real-time PCR methods for the rapid detection of Xylella fastidiosa for quarantine and field applications Handheld device for real-time, quantitative, LAMP-based detection of Salmonella enterica using assimilating probes Evaluation of Loop-Mediated Isothermal Amplification for Rapid Detection of Erwinia amylovora on Pear and Apple Fruit Flowers Simpler, More-Specific Methods for Improved Molecular Detection of Phytophthora ramorum in the Field Detection of Botrytis cinerea by loopmediated isothermal amplification Loop-mediated isothermal amplification (LAMP): a versatile technique for detection of micro-organisms Evaluation of Loop-Mediated Isothermal Amplification (LAMP) for Malaria Diagnosis in a Field Setting Workshop on Xylella fastidiosa: knowledge gaps and research priorities for the EU --2016 -EFSA Supporting Publications -Wiley Online Library Development and Validation of a Rapid, Single-Step Reverse Transcriptase Loop-Mediated Isothermal Amplification (RT-LAMP) System Potentially to Be Used for Reliable and High-Throughput Screening of COVID-19 SARS-CoV2 RT-LAMP test for Point-of-Care and diagnostic lab Clinical evaluation of self-collected saliva by RT-qPCR, direct RT-qPCR, RT-LAMP, and a rapid antigen test to diagnose COVID-19 A Novel Reverse Transcription Loop-Mediated Isothermal Amplification Method for Rapid Detection of SARS-CoV-2 A Single and Two-Stage, Closed-Tube, Molecular Test for the 2019 Novel Coronavirus (COVID-19) at Home, Clinic, and Points of Entry Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay Development of a reverse transcription-loop-mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2 The authors wish to acknowledge the Team from New England Biolabs France for technical support, the Virology unit and all contributors to the study of University Hospital of Caen and Loo Dee Science company, the "Agence de l'Innovation de Défense" (French Defence Innovation Agency) and the "DGA Maitrise NRBC" (Armament General Directorate CBRN Defence Center). Copan Compatible