key: cord-0808834-t1zttnqe authors: Pearce, Emily; Campen, Matthew J.; Baca, Justin T.; Blewett, John P.; Femling, Jon; Hanson, David T.; Kraai, Erik; Muttil, Pavan; Wolf, Blair; Lauria, Michael; Braude, Darren title: Aerosol generation with various approaches to oxygenation in healthy volunteers in the emergency department date: 2021-03-02 journal: J Am Coll Emerg Physicians Open DOI: 10.1002/emp2.12390 sha: fac6c994f073a5dfebb5033c9d264c25284f1279 doc_id: 808834 cord_uid: t1zttnqe OBJECTIVES: Health care workers experience an uncertain risk of aerosol exposure during patient oxygenation. To improve our understanding of these risks, we sought to measure aerosol production during various approaches to oxygenation in healthy volunteers in an emergency department. METHODS: This was a prospective study conducted in an empty patient room in an academic ED. The room was 10 ft. long x 10 ft. wide x 9 ft. tall (total volume 900 ft(3)) with positive pressure airflow (1 complete turnover of air every 10 minutes). Five oxygenation conditions were used: humidified high‐flow nasal cannula (HFNC) at 3 flow rates [15, 30, and 60 liters per minute (LPM)], non‐rebreather mask (NRB) at 1 flow rate (15 LPM), and closed‐circuit continuous positive airway pressure (CPAP) using the ED ventilator; in all cases a simple procedural mask was used. The NRB and HFNC at 30 LPM maneuvers were also repeated without the procedural mask, and CPAP was applied both with and without a filter. Each subject then sequentially underwent 8 total oxygenation conditions, always in the same order. Each oxygenation condition was performed with the participant on a standard ED bed. Particles were measured by laser aerosol spectrometer, with the detector sampling port positioned directly over the center of the bed, 0.35 meters away and at a 45‐degree angle from the subject's mouth. Each approach to oxygenation was performed for 10 minutes, followed by a 20‐minute room washout (≈ 2 complete room air turnovers). Particle counts were summated for 2 size ranges (150–300 nm and 0.5–2.0 μm) and compared before, during, and after each of the 8 oxygenation conditions. RESULTS: Eight adult subjects were enrolled (mean age 42 years, body mass index 25). All subjects completed 8 oxygenation procedures (64 total). Mean particle counts per minute across all oxygenation procedures was 379 ± 112 (mean ± SD) for smaller aerosols (150–300 nm) and 9.3 ± 4.6 for larger aerosols (0.5–2.0 μm). HFNC exhibited a flow‐dependent increase in particulate matter (PM) generation—at 60 LPM, HFNC had a substantial generation of small (55% increase) and large particles (70% increase) compared to 15 LPM. CPAP was associated with lowered small and large particle generation (≈ 10–15% below baseline for both sizes of PM). A patient mask limited particle generation with the NRB, where it was associated with a reduction in small and large particulates (average 40% and 20% lower, respectively). CONCLUSION: Among 3 standard oxygenation procedures, higher flow rates generally were associated with greater production of both small and large aerosols. A patient mask lowered aerosol counts in the NRB only. Protocol development for oxygenation application should consider these factors to increase health care worker safety. Results: Eight adult subjects were enrolled (mean age 42 years, body mass index 25). All subjects completed 8 oxygenation procedures (64 total). Mean particle counts per minute across all oxygenation procedures was 379 ± 112 (mean ± SD) for smaller aerosols (150-300 nm) and 9.3 ± 4.6 for larger aerosols (0.5-2.0 µm). HFNC exhibited a flow-dependent increase in particulate matter (PM) generation-at 60 LPM, HFNC had a substantial generation of small (55% increase) and large particles (70% increase) compared to 15 LPM. CPAP was associated with lowered small and large particle generation (≈ 10-15% below baseline for both sizes of PM). A patient mask limited particle generation with the NRB, where it was associated with a reduction in small and large particulates (average 40% and 20% lower, respectively). Conclusion: Among 3 standard oxygenation procedures, higher flow rates generally were associated with greater production of both small and large aerosols. A patient mask lowered aerosol counts in the NRB only. Protocol development for oxygenation application should consider these factors to increase health care worker safety. aerosols, health care workers, high-flow nasal cannula, oxygenation, particulates, SARS-CoV-2 Patients presenting to the emergency department with acute hypoxemic respiratory failure may require a range of oxygenation therapies. All such therapies may theoretically generate droplets and/or aerosols, which place health care workers (HCWs) at risk for various infectious diseases. Currently, the potential for airborne transmission of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from patients to HCWs is a global health issue. 1 10 This study failed to identify significant trends in particle production, owing in part to a limited number of study subjects (n = 2). We have built on the model developed by Miller et al to study further the particle generation during various approaches to oxygenation of adults. We specifically sought to estimate aerosol generation from healthy subjects during several common approaches to oxygenation: high-flow nasal cannula (HFNC), non-rebreather facemask (NRB), and continuous positive airway pressure (CPAP). This was a prospective study of aerosol particle generation during various approaches to oxygenation using healthy volunteers. The study was conducted in a single unoccupied room in an academic ED; the same room was used for all subjects. The ED room was positivepressure ventilated, at roughly 6 room exchanges per hour (1 every 10 minutes). Inflow was above the head of the patient, and outflow was near the sliding door, close to the floor ( Figure 1 ). The Human Research Review Committee of the University of New Mexico Health Sciences Center approved the study before commencement. F I G U R E 1 Experimental layout in the emergency department cubicle. Room dimensions were ≈ 10 ft x 10 ft x 9 ft (900 ft3 or 25 m3). Ventilation systems were placed on the opposite side of the stretcher from the Laser Aerosol Spectrometer and particle sampling tube. The sampling tube was placed in the approximate position of a bedside health care worker Healthy subjects between the ages of 25 and 55 years provided verbal consent to participate. Subjects included members of the research team and local HCWs. By institutional policy, subjects were required to confirm having no symptoms related to COVID-19 before coming on campus each day. The 5 approaches to oxygenation were HFNC at 3 flow rates, NRB, and Subjects were seated 60 degrees upright on an ED bed ( Figure 1 ). Subjects were asked to remain relatively stationary throughout the testing period and were instructed to breathe normally; no specific protocol for coughing or speaking was implemented. Subjects underwent 8 sequential oxygen procedures, each lasting 10 minutes in duration followed by a 20-minute washout period. At the end of each 10-minute The risks to health care workers from infectious aerosols remain uncertain, despite the urgency of this knowledge during the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. In a simulation-based study of 8 healthy adults in an emergency department, the investigators present a model for future studies and provide evidence for the relative production of aerosols across a range of oxygenation procedures, with higher flow rates generally associated with greater aerosol production. A single polyurethane tube (1/4" inner diameter) was placed 0.35 meters and 45 degrees from the subject's mouth ( Figure 1 ) and connected to a laser aerosol spectrometer (Model 3340A; TSI, Inc., Shoreview, MN, USA). The placement of the sampling tube was designed to reflect a common position and distance for HCWs actively treating a patient. Particulate matter (PM) was continuously sampled at 1-minute intervals. Importantly, this assessment does not discriminate between naturally occurring background PM and subject-derived PM. The investigator remaining in the room wore a procedural mask, stood toward the door (away from the air intake), and kept movement to a minimum (to minimize distribution and measurement of background of PM). We summated PM counts in 2 size ranges: 150-300 nm and 0.5-2.0 µm. We selected these ranges owing to much higher background levels of nanosized particles (<300 nm) and because analyzing PM counts separately afforded a better opportunity to observe meaningful trends for different oxygen delivery systems. Furthermore, because of the high variability of background PM levels before the oxygenation procedures, for both PM size ranges and each oxygenation procedure we also summarized PM data for 4 epochs: the 5 minutes before, the first and second 5 minutes during, and the first and second 5 minutes following oxygenation. For both the smaller (150-300 nm) and larger (0.5-2.0 µm) PM ranges, we calculated the mean PM count and SD for the 4 5-minute epochs of each oxygenation procedure. We then used 1-or 2-way Eight healthy subjects were enrolled and completed the full study protocol (8 oxygenation sessions each, 64 total; sessions completed between May 7-22, 2020). Subject demographics and predicted lung vital capacity 11 are provided in Table 1 . Average PM counts for all 64 oxygenation procedures were 392 ± 142 per minute (mean ± SD) for smaller PM (150-300 nm) and 10.2 ± 6.2 counts per minute for larger PM (0.5-2.0 µm). For the 5-minute baseline period, the mean PM counts were 388 ± 112 per minute for the smaller range and 9.4 ± 5.1 per minute for the larger range (baseline relatively stable across all subjects and oxygenation procedures). HFNC generated PM in a flow-related manner, with particle counts The NRB (only tested at 15 LMP) led to modest increases in PMcounts increased from baseline by a maximum of 5% and 15% for small and large PM, respectively ( Figures 4A,B and 5A 65% reduction, P < 0.001) immediately following the 10-minute oxygenation. A 2-way repeated-measures ANOVA confirmed that the use of the mask and the mask x time interaction affected the reduction in larger PM (P = 0.044 and P < 0.0001, respectively). Similar trends were noted for smaller PM, with the mask factor alone nearing significance (P = 0.0687, 16.5% of variance) and the "mask x time" interaction significantly affecting PM levels (P = 0.0007, 6.3% of variance). CPAP was associated with a maximum 15% reduction in smaller PM counts (P < 0.0001; Figures 4C and 5C ). Larger PM showed no significant change from baseline ( Figure 4D, 5D ). The addition of filtration to CPAP was not associated with significant changes in PM counts in either size ranges. To examine further the impact of a simple facemask on PM counts, we performed a follow-up 3-way ANOVA, combining data from Our study has several important limitations. First, we included only a small number of healthy subjects, and we did not attempt to model issues known to produce more aerosols, such as coughing, sneezing, or increased airway mucous. A larger, more diverse sample of patients might produce meaningfully different PM count patterns. Second, we found that day-to-day variation in background PM counts in the study room precluded any reasonable estimates of "background" versus "subject-derived" PM. When we attempted to measure background levels in the empty room, we often measured particle counts at or above those measured when subjects and investigators were present. We estimate that the subject-derived PM is a very small percentage of our totals-at most 30%. Therefore, changes in total PM counts actually reflect a muted overall change of subject-derived PM, which are much more substantial than we could delineate. Lastly, we studied the spatial distribution and air convection pattern of a single room. The spatial distribution was designed to mirror a HCW in a working position close to the head of a patient. However, the room and the subject were quite still during the process, and the investigator generally stood further away from the bedside. In a true clinical setting, a great deal of activity would lead to a more complex pattern of air convection and PM production and movement. Methods to delineate patient-derived versus other PM in clinical settings would be exceedingly challenging. Research into the generation, dispersion, and duration of aerosols is essential for optimal clinical guidance to protect HCWs from infectious diseases during respiratory procedures. The present study adds to the literature by (1) Aerosol transmission of infectious diseases, especially in a closed setting, is an essential means of viral spread. 12 Humans can produce a wide range of particle size range during breathing, coughing, and sneezing. Although the SARS-CoV-2 virus ranges in size from 75 to 160 nm, 5 patients can produce particles ranging from 0.05 to >100 µm. 6 Our results in healthy human subjects were consistent with an in silico transmission modeling study 13 and a recent study of a simulated rates. 14 In that study, investigators also modeled aerosol spread for patients with moderate and severe lung disease, which ultimately dampened flow and led to reduced aerosol distribution. A general gap for these studies, as well as the present report, is the absence of information on whether measured droplets had the potential to carry pathogens. In summary, we modeled the position of HCWs directly working with a patient in an ED bed and found that, with healthy subjects, specific oxygenation procedures can increase or decrease the PM burden in the room. The contribution to background PM counts, however, was relatively low. Based upon our findings and until additional studies are conducted, it may be advisable to restrict HFNC to 30 LPM or less when HCWs' respiratory protection cannot be assured. Placing a procedure mask over oxygen-delivery masks and cannulas also seems prudent to limit the potential for viral transmission. The impact of any of these changes may be modest, however, and HCW should continue to practice optimal PPE donning and doffing to optimize protection. This work was supported in part by the University of New Mexico Clinical and Translational Sciences Center Career Development Program (KL2 TR001448) and also by the University of New Mexico Center for Metals in Biology and Medicine (P20 GM130422). All authors have no financial interests to disclose. The effects of internal filtration of a CPAP device on subject-derived 0.5-2 µm aerosol formation. Data shown are mean ± SEM. Asterisks indicate significant difference for mask usage at specific time points by a 2-way repeated measures analysis of variance (*P < 0.05, **P < 0.01). For CPAP, no significant differences for filtration were noted, but the overall reduction in 150-300 nm particulates during the 10-minute procedure was highly significant (P < 0.0001) compared to preprocedure for both arms of the experiment High-flow nasal cannula for acute hypoxemic respiratory failure in patients with COVID-19: systematic reviews of effectiveness and its risks of aerosolization, dispersion, and infection transmission Transmission of COVID-19 virus by droplets and aerosols: a critical review on the unresolved dichotomy Coughs and sneezes: their role in transmission of respiratory viral infections, including SARS-CoV-2 Oxygen therapy and risk of infection for health care workers caring for patients with viral severe acute respiratory infection: a systematic review and metaanalysis Measurement of airborne particle exposure during simulated tracheal intubation using various proposed aerosol containment devices during the COVID-19 pandemic The role of particle size in aerosolized pathogen transmission: a review Exhaled air dispersion during noninvasive ventilation via helmets and a total facemask Comparison of high-flow nasal cannula versus oxygen face mask for environmental bacterial contamination in critically ill pneumonia patients: a randomized controlled crossover trial Exhaled air dispersion during coughing with and without wearing a surgical or N95 mask Aerosol risk with noninvasive respiratory support in patients with COVID-19 Pulmonary insufficiency; physiological classification, clinical methods of analysis, standard values in normal subjects Aerosol transmission of SARS-CoV-2? Evidence, prevention and control Preliminary findings on control of dispersion of aerosols and droplets during high-velocity nasal insufflation therapy using a simple surgical mask: implications for the high-flow nasal cannula Exhaled air dispersion during high-flow nasal cannula therapy versus CPAP via different masks is a Professor in the Department of Emergency Medicine and specializes in EMS and Disaster Medicine at the University of New Mexico Aerosol generation with various approaches to oxygenation in healthy volunteers in the emergency department