key: cord-0807600-ie10u402 authors: Jan, Saeed Ullah; Ali, Sikandar; Abbasi, Irshad Ahmed; Mosleh, Mogeeb A. A.; Alsanad, Ahmed; Khattak, Hizbullah title: Secure Patient Authentication Framework in the Healthcare System Using Wireless Medical Sensor Networks date: 2021-07-22 journal: J Healthc Eng DOI: 10.1155/2021/9954089 sha: 39b543c665571a16e8dd9efb97523234667bfe55 doc_id: 807600 cord_uid: ie10u402 Biosensor is a means to transmit some physical phenomena, like body temperature, pulse, respiratory rate, electroencephalogram (EEG), electrocardiogram (ECG), and blood pressure. Such transmission is performed via Wireless Medical Sensor Network (WMSN) while diagnosing patients remotely through Internet-of-Medical-Things (IoMT). The sensitive data transmitted through WMSN from IoMT over an insecure channel is vulnerable to several threats and needs proper attention to be secured from adversaries. In contrast to addressing the security of all associated entities involving patient monitoring in the healthcare system or ensuring the integrity, authorization, and nonrepudiation of information over the communication line, no one can guarantee its security without a robust authentication protocol. Therefore, we have proposed a lightweight and robust authentication scheme for the network-enabled healthcare devices (IoMT) that mitigate all the identified weaknesses posed in the recent literature. The proposed protocol's security has been analyzed formally using BAN logic and ProVerif2.02 and informally using pragmatic illustration. Simultaneously, at the end of the paper, the performance analysis result shows a delicate balance of security with performance that is often missing in the current protocols. A healthy human body is a prerequisite to happiness, mental ease, and calm existence. Such a body ensures a sound and robust mind too. On the other hand, an unhealthy physique necessitates caring, treating, diagnosing, and preventing a human for injury or any other illness collectively termed as a healthcare system. While managing healthcare, sight negligence can upset the whole process and may turn counterproductive. is negligence and the flawed nursing system are an embarrassment for patient monitoring due to the attached modules to the human body and recurrent power supply. Each time replacement of power-source can also create serious risks for the patient's life. To ease the work of the whole team and stop human errors and aid the medical professional in examining a patient for a disease, technology and network-oriented devices (Internet-of-Medical-ings (IoMT)) are used that guarantee an authentic result [1] . IoMT facilitates healthcare personnel over the Internet and a decision control system without humanpatient or patient-computer interaction. Such emerging technology needs novel services for grasping the attention of healthcare industries for the remote monitoring of their patients. is remote monitoring will not only minimize the cost of a disease for a layman, but also provide the facility for the maximum diagnosing of a patient in this crowded world [2] . Similarly, the healthcare industries are ever-growing, taking over 20.4bn technological interconnected and network-enabled devices. ese devices have communication competencies that remotely collect patient information and send it to medical professionals for examination and treatment recommendations. However, the transmission of such sensitive data (body temperature, oxygen saturation, the glucose level in the blood, respiratory rate, heartbeat/ pulse rate, etc.) is performed via an open network channel, vulnerable to several threats. It needs proper attention to make it secure. Security, communication, and computation cost or media consumption are also necessary, so that a doctor may easily recognize hand gestures, blood vessels contraction/relaxation, the flow of message in the neuron, and central nervous system (CNS) response of a patient, etc. Attention is also needed for a robust detection system, different color recognition, and stereo sequence of an image control via media [3] . e data acquisition and processing competencies of scalable and practicable devices/machines, interconnected devices, embedded sensors, and installed software applications that can push data flow for patient monitoring are at peak today. After sensing the patient, data is transmitted to the medical professional with wireless networks named Wireless Medical Sensor Network (WMSN) (WMSN is a type of self-organizing network with multiple or miniembedded sensors inside the human body to sense physical conditions with wireless connectivity. e working procedure of WMSN is to transport data among different participating entities or in the coverage area. WMSN is the fundamental foundation of Internet-of-Medical-ings (IoMT) that can enhance patients' medical treatment) to practice for the diagnosis and medical care. e mutual authentication and cross-verification of each participating entity for such a sensitive transmission are impossible without a key-agreement protocol. It not only facilitates patients at home but is useful in diagnosing various types of diseases as well. Besides, health experts, too, are assisted in assessing and giving advice. While patients' data and physicians' diagnoses are linked/transferred via an open network channel, slight negligence may not only be detrimental and counterproductive, but will shatter people's trust as well. erefore, it needs extra care and a renewed approach to tackle the issues [4] . Amin et al. [5] proposed the scheme for communicating patient-sensitive information to the doctor/medical professional for diagnosis, which is vulnerable to man-inthe-middle, privileged insider attacks, and lack of mutual authentication. We proposed an improved, lightweight authentication framework that mitigates these weaknesses. e proposed scheme's security has been analyzed using the BAN logic and Provierif2.02 toolkit with an informal discussion for justification. e evaluation results show that the scheme is lightweight in contrast to the state-of-the-art protocol in recent literature. As such, we recommend the proposed protocol for practical implementation in the healthcare online patient diagnoses environment. e main contributions of the research are as follows: (1) In IoMT, the medical professionals having mobiledevice can securely obtain the real-time patient's status for diagnosing (2) e outdated data broadcasting flaw common in prior protocols designed for the healthcare system has been fully addressed in this research work (3) A simple hash cryptographic function and publicprivate key pair are used for designing the security protocol that is lightweight and balances performance with security for the fast, reliable, consistent, and low-latency Wireless Medical Sensor Network (WMSN) (4) e sensor revocation/reissue phase demonstrates that, upon stolen or misplaced sensor or mobile device at any time, no one can assess the internally stored credentials, which means that the prospective scheme is free of offline/online identity guessing and stolen-verifier attacks (5) e protocol's security has been scrutinized both formally using BAN logic and informally using realistic illustration, showing the protocol's robustness (6) e protocol's scalability, reachability, integrity, and authorization, as well as security features, have been achieved using ProVerif2.02 simulation Model. e wireless technology for the healthcare industry and installed applications in network-enabled devices can communicate seamlessly to the proper device via WMSN, which has limited battery capacity and low latency. It offers back-end services, quick and intelligent network features for IoMT in healthcare services delivery, while the embedded sensors in the human body can collect and communicate physical conditions to the gateway node using the said limited featured wireless network, for example, (i) visual sensor for sight checkup, (ii) pressure sensor on examining the breath duration of a patient or stress of central nervous system (CNS) or the lower part of the mouth, (iii) temperature sensor for finding the normal body heat, (iv) oxygen saturation sensor for oxygenated blood monitoring, (v) EEG/ECG/MRI sensor is for heart and other parts checkup, (vi) ventilator sensor to provide oxygen continuously to a patient, and (vii) imaging, treatment, diagnosing, and data analytics, etc. Figure 1 represents the system model or architecture in this paper having four (04) main participants: online service provider for the healthcare system (Certificate Authority), the gateway node (GW), a set of sensors inside the patient body, and external user (medical professionals). e certificate authority (CA) is a specialized company that provides connectivity, data processing, and real-time problemsolving capabilities. e gateway node (GW) is an essential component of the system. All sensors and mobile devices used by patient/medical professionals must be fitted with a gateway node (GW) and connected with alternative network services such as 5G, 6G, and other wireless communication interfaces. e external user (medical professional) can access a designated sensor (patient monitoring) from some ward/location/area. When a patient is in a specialized region or location, the gateway node (GW) controls data broadcasting and verifies the patient's validity. e identification of illegitimate sensors or patient or mobile device or medical professional in the designated area or location or any place may also be easily recognized due to the capability of the intermediary agent (gateway-node (GW)). It is noteworthy that the Certificate Authority (CA) is officially a fully trusted entity. eir confidence must be consistent, because the trust deficit may impair the system's reliability. e proposed scheme ensures that the registration center can be fully trusted by the patient/sensor/medical professional and the gateway node (GW). In contrast, any other entity alone may not be fully trusted. e Dolev and Yao [6] model tells us about an adversary's authority between two communicating bodies through an open network channel. According to this model, all the possibilities with an attacker are as follows: (i) An adversary might extract the stored data from the GW memory/sensor/mobile device of a medical professional and verify some credentials (ii) An adversary might alter, delete, update, corrupt, or inject false information on participants' communication over a public network channel (iii) Adversaries can also have the capabilities to replay, modify, or delete the beneficial information exchange among the participants over a private channel (iv) An adversary can also obtain the internal sensitive credentials from a stolen sensor/mobile device of a medical professional or from the memory of misplaced sensor/mobile device of medical professional either by reverse engineering technique or by using some critical tags in offline mode, but cannot do both at the same time With an adversary, our threat model additionally includes the following possibilities: (1) Privacy reat Suppose that an adversary uses aircrack-ng software to extract sensor locations and other helpful information from stolen data packets. In that case, they are using airodump-ng software to detect signal strength, filtering it for additional attacks, and disrupting the synergy by utilizing airplay-ng software to deauthenticate it. e attacker also has the chance to disrupt the entire network by transferring disassociation packets frequently to disguise its normal operations. (2) Stolen-Verifier reat Suppose that an attacker can physically steal the mobile device of a medical professional or sensor used by a patient and vice versa, or if it is misplaced, lost, or destroyed somewhere from a legitimate user, an adversary can attack it in order to obtain access to the information recorded in the sensor's/mobile device's memory. After that, they can reveal the encrypted data and begin authentication with another hospital's gateway node or sensor used by other medical professionals or patients. Suppose that an adversary can drill the data from IoMT and control the communication channel traffic of broadcasting information towards the sensors. e traffic also consists of sensitive patient's physical phenomenon packets transferred between a medical professional's sensor/mobile device and a gateway node; after the adversary's forensic, the packets in traffic can reveal sensitive information about the system. e adversary evaluated it to see if it might be used as a threat. (4) Access Control reat e adversary also can understand the different policies and inject false information in the communication path, which connects the different participants for useful information exchange. ey can also gain complete control of the channel by examining the overall system activities. (5) Identity Spoofing reat An adversary can obtain the identity of a legitimate participant in the system and maliciously spoof/fool the system. If they become successful in getting legitimate participants' identities, they can easily control the communication line for altering, deleting, or injecting false information in it. Architecture of the Network Model. As explained earlier, the main participants in the proposed system are Certificate Authority (CA), Gateway Node (GW), Sensor Node (SN), and Medical Professional (Mobile-Device). e general working scenario of the system is as follows: (i) Gateway node, sensor node, and a medical professional will first register with the certificate authority (ii) Intelligent sensors embedded inside the patient's body can sense physical phenomenon and broadcast it towards the gateway node through resource constraint WMSN (iii) From the gateway node, with the help of WMSN, the data is transmitted toward medical professionals for possible diagnosis e diagrammatic representation of the proposed framework is shown in Figure 2 . Journal of Healthcare Engineering 3 Advances in technology for IoMT devices to transmit data of the healthcare domain and communicate with one another are increasing rapidly, and its security is a challenging task. Since their interconnectivity is vulnerable to several threats like other network-enabled devices, therefore, it needs to be appropriately authenticated with each other. Recently, Singh et al. [7] proposed a framework for orthopedics patients in the pandemic period of COVID-19. Such a patient is unable to attend the hospital for treatment due to chances of Corona. ey demonstrated how the orthopedics' patient could use it for his/her healthcare at home while being remotely connected with the hospital. e connectivity of both patient and doctor with the hospital using cloud computing is mandatory. Cloud computing offers infrastructure in three specific models, i.e., Software as a Service (SaaS), Platform as a Service (PaaS), and Infrastructure as a Service (IaaS). However, the stakeholders' cloud-saved database usage can create security and interoperability issues; therefore, [7] failed to design a dynamic authentication scheme for the participants. Alsubaei et al. [8] proposed an IoMT security assessment software framework for the developers/hospitals. But they failed to express the secure authentication of associated devices for examining a patient. Sanaz et al. [9] presented secure IoT-Based e-Healthcare architecture for patient monitoring. ey installed an intelligent gateway among all the participants during patient monitoring. ey proposed an authentication protocol that authenticates all the entities, including an embedded sensor inside the patient for sensing patients' data, time, temperature, and location intelligently, and transmits them to the health professional. A certificate-based methodology was adopted for the transport layer to work on Wireless Medical Sensor Networks (WMSNs), having a gateway node, a full-power computer system, and application software. Subsequently, Lee et al. [10] suggested that a high-speed ICT tool can remotely be diagnosing a patient by monitoring and supervising his/her physical phenomenon, so that treatment costs can be minimized. ey stated that the Graphical Processing Unit (GPU) is mandatory to reduce the load on the CPU during patient-sensitive data processing. However, they used simple encryption/decryption functions, which are not insufficient for security, privacy, and parallel computation. Rahimi et al. [11] enhanced the Datagram Transport Layer Security (DTLS) between the gateway nodes, patent, and medical professional. In addition, they stated that there is no need for a certificate for session initiation among the participants. Gope et al. [12, 13] suggested a useful structure for IoMT applications for data collection and interpretation based on privacypreserving (P2DCA). eir architecture splits an interconnected network of integrated multimedia sensors into several clusters. A Cluster Head (CH) was defined as a bunch responsible for protecting the privacy of member MSNs and collecting data and location coordinates. Later, grouped multimedia data was analyzed on the cloud server using an artificial neural network for counterpropagation to extract meaningful information through segmentation. To integrate the infrastructure with mobile devices and overcome the shortage of medical services, Usman et al. [14] proposed an authentication protocol that mitigates medical resource misuse. A patient used its user's name and password on a mobile device to sign in to the public. It is without a password and identity table in the database. It satisfies specific standard protection criteria like protecting against offline password guessing attacks, replay attacks, impersonation attacks, man-in-middle attacks, and insider attacks. However, during decision-making at any crucial time, strong encrypted, authentic, and digitally signed information might be difficult to access even for a legitimate user and also vulnerable to known-key and forgery attacks. Moghaddam et al. [15] implemented a client-based user authentication agent to validate client-side user identity; SaaS has been used to validate unregistered machines' authentication. e scalability, efficiency, security, man-inthe-middle attack, brute force attack, and timing attack have been evaluated according to the parameters. However, they used two separate servers for authentication and cryptography, which is the wastage of resources. Because the same can be managed from a single centralized server, this might decrease the overall cost and increase security. Satheesh et al. [16] proposed a framework for security and privacy in the healthcare system. Patient-centric confidential information and access control with an improved method of encryption was considered. A digital signature algorithm (DSA), patient pseudoidentity, and personal sensitive information protection were identified. e researchers addressed an enhanced security model for authentication and authorization to discover a new technique that can build security, privacy, and cross-verification of ehealthcare credentials. Allouzi and Javed [17] suggested a framework for authentication of health care devices called Soter. It offers a range of advanced features, such as trust of medical devices, promoting virtual federations, and a trust circle for customized and dynamic access control policy. It is worth noting that when an adversary can get a patient's login information by calling close to him, he/she can account for a hijacking attack on it. [18] [19] [20] proposed a cryptographic-based authentication framework, but such frameworks do not provide a fast and secure authentication mechanism, because the performance and security are unable to match each other. e researchers of [21, 22] designed a robust protocol for WMSN, in which multimedia type message was securely transmitted among peers. Still, the networks have not been fixed during multimedia message transmission and created hurdles for the end-user. Shrestha et al. [23] suggested a privacy-protection authentication scheme for healthcare information systems, in which they used digital signatures. A blockchain is also a means of security for protecting healthcare system records. In this regard, Mikula and Jacobsen [29] proposed a blockchain-based authentication scheme for a centralized digital system. eir approach was implemented in the healthcare domain, in which fundamental patient data of size 3.8 MB has been executed in 2-3 seconds. Immutable data history has shown slow execution and wastage of resources data concerning patients. Further, Das et al. [30] proposed a dynamic identity-based authentication scheme that can resist forgery attacks, insider attacks, stolen verifier attacks, and guessing attacks. However, their strategy is suffering from a privileged insider attack, as the password and identity are transmitted from the user openly towards the server. Kumari et al. [31] provided highlevel protection without reducing cloud/fog computing performance, mostly when IoMT is used, and they named it Fog-based Access Control Model (FACM). A cloud-based approach is applied in either mobile or nonmobile context, operating as an additional layer for fog servers, and can offer personalized access control environment. However, the execution time is related to several inputs. Upon increasing intakes, the model's performance will be degraded and vulnerable to impersonation and parallel session key attacks and lacks mutual authentication. Finally, Rathore et al. [32] demonstrated a novel multilayer perception model for securely diagnosing diabetic patients. ey said that the insulin pump inside a patient that controls blood glucose transmits patient sensitive information via the wireless channel and can easily be compromised. Neural-network-based multilayer security can provide security to the embedded medical device inside the patient. eir study revealed 91% accuracy upon an evaluation of the linear vector machine. However, still, no one can trust its reliability for such a sensitive treatment. Wu et al. [33] used Identity and password for designing a protocol via WMSN and healthcare applications. ey said that, to overcome the noted disadvantages in their designed protocol, a novel approach is required. eir scheme attracts the modern healthcare industry, in which a paramedical professional can examine patent data remotely using a mobile device. However, because there are no encryption/decryption functions, their scheme is vulnerable to stolen-verifier attacks and privileged-insider attacks. Some related literature review is comprehensively described in Table 1 . Amin et al. [5] proposed a scheme for IoMT using WMSN in the healthcare domain. eir protocol consists of four phases, i.e., setup phase, registration phase, login and authentication phase, and password change phase. Each of these phases is described one by one under the following headings; notations used in their scheme and their description are shown in Table 2 . e registration center (RC) first selects a secrete key K for the gateway node (GW) and calculates SK GW-SNj � h(ID SNj ||K). In contrast, n is the number of embedded sensors inside the patient's body, and its j th value lies between 1 and n (1 ≤ j ≤ n). e collision-free one way-hash cryptographic function is also defined here in this phase of the protocol as h:{0, 1} * ⟶ {0, 1} l . . It stores {TID ia , D ia } in its database and sends {TID ia , Reg ia , A ia , C ia , h(·)} towards user U ia over a secure channel, where the user can also store all these parameters in its memory, while, for a patient's registration, he/she first provides his/her name to the registration center (RC). RC assigns the requisite sensor and sends it to the e proposed scheme consists of a secure and efficient end-user authentication and authorization architecture based on the certificate based DTLS handshake, secure endto-end communication based on session resumption, and full mobility based on interconnected gateways e authentication is performed in several steps, due to which multiple round trips can degrade the performance of the process. Also, the securities of the said architecture can easily be breached by an attacker [25] Borthakur et al. is work proposes a fine-grained access control mechanism suitable for various implementation scenarios, including data storage, directories, and file management e execution time length is associated with the number of the input task. erefore the performance will be degraded by increasing the number of input tasks [26] Dastjerdi and Buyya BLE bonding process is paper addressed some of the fundamental problems. In designing, implementing, and deploying an endto-end healthcare application that leverages the advantages of the fog computing approach If the number of corresponding ECG devices increases, more storage will be required, and throughput will be reduced [27] Engineer et al. Journal of Healthcare Engineering medical professional for future monitoring, prescription or diagnosis. Phase. e login and authentication phase of [5] has been completed in the following steps: (i) In this phase of the protocol, the user U ia provides identity ID ia and password PW ia using hand-held device (Smart Phone) and computes if a match occurs, further computation is performed; else, termination message is displayed. It generates an arbitrary number R 1 and computes if not matched, authentication is denied; else, gateway node generates another arbitrary number R 2 and computes if not matched, a denied message is displayed on the user's screen; else, the user is asked to enter a new password. Upon receiving the password change message, the user is now able to enter a fresh password PW new ia of his/her own choice and computes HPW new [5] . By applying the Dolev and Yao [6] model, we find the following weaknesses in Amin et al. protocol: (1) Masquerade Attack An attacker can quickly identify the secret credentials from CID ia � ID ia ⊕ h(TID ia ǁR * ia ǁT 1 ) and M 2 � h(R ia ǁT 1 )R 1 . e adversary first recovers ID ia from CID ia , and then R 1 from M 2 . ese two are crucial parameters, and once an attacker gets access to these, he/she can masquerade the system. (2) Privileged Insider Attack Let a user U ia transmit identity ID ia and password PW ia towards gateway-node (GW). e system operator, in which he/they can use the system, can quickly identify user credentials by either guessing password or computing HPW ia * � h(ID ia ⊕ PW ia ) and run tuples to correct the password. In such a scheme, authors do not share the synchronized resource's detail. For example, after a successful login of the medical professional to monitor his/her patient, such scheme missed the secure log out procedure of him/her. According to the given scenario, the mutual authentication and cross-verification key are still stored in the synchronous storage. An attacker can easily copy and , and M 8 � h(R 2 ) ⊕ R 3 are transmitted over a public network channel openly, in which an adversary can catch and figure out credentials by specifying location by repeatedly monitoring different sessions started by the same user. To prevent the adversary from figuring out any identity or tracing any credentials like the exact location of a legitimate user, it must be transmitted securely or linked with a vigorous session shared key (SK). (7) Mutual Authentication Issue e gateway node computes the session key as SK GW−SNja � h(IDS Nja ||K), and the sensor node SK � h(M / 6 ||R 2 ||R 3 ). In the second round, the gateway node computes the shared session as SK / � h(h(ID ia || R 1 ||R 2 )||R * 2 ||R / 3 ) and user SK * � h(h(ID ia ||R 1 ||R * 2 )|| R 2 ||R * 3 ), which means that the key between the user and gateway node is computed. Still, the sensor embedded in the patient does not know about the shared session key. erefore, the scheme is failed to deliver mutual authentication and cross-verification with/of all the participants. Besides the drawbacks mentioned above, [5] did not explain the expansion/recede of the network by the addition/revocation of a new patient/professional. e scheme has missed explaining sensor/patient revocation/reissue or professional revocation/reassignment phases. We will use critical public infrastructure to generate dynamic numbers for each session for such a resource deficit environment. e scheme consists of the setup phase, registration phase, key-agreement phase, password change phase, and revocation/reissue phase; each of these is discussed one by one under the following headings: Extract a prime P, the CA first generates two random numbers x, y of size 160 bits, compute a secret key s � xP, and l � sP called a public key, collision-free hash function H(·):{0, 1} * ⟶{0, 1} l . Keep (ID SNj ||s) in sensor node, s, and l in gateway-node, which is the key role in the whole system. is phase consists of two subphases, including patients' and medical professionals' registration subphases, which are described as follows: (1) Patient's Registration A patient first sends his/her name to the CA. CA allocates the requisite accurately and offers/entitles the services to medical professionals. CA also shares a patient's Identity and assigned sensor information to a medical professional. (2) Professional Registration Phase e user selects identity ID ia , password PW ia , nonce N ia and computes DPW ia � h(PW ia ||N ia ||ID ia ), DID ia � h(ID ia ||N ia ) and transmits {DPW ia , DID ia } to gateway node over a secure channel. e gateway node has already a secret key s and computes e gateway-node (GW) stores O and sends {A, B, C, h(·)} towards user over a secure channel and stores all these parameters in its own record too as shown in Figure 3 is phase of the proposed protocol is accomplished in the following steps: (i) A user provides his/her identity, and password computations performed are HPW * � h(ID ia ⊕ PW ia ), A * � h(ID ia ||s||HPW), confirms A * ? � A; if not found valid, computation stops; else, it generates R 1 , s * and computes B * � C ⊕ h(ID ia ⊕ A * || HPW * ), F � B * ⊕ h(s * ||A * ||T 1 ), J 1 � h(ID ia ||B * ||R 1 || T 1 ), J 2 � ID ia ⊕ h(s||T 1 ) and L 1 � E l (J 2 ||R 1 ||s * ). if not matched, the process terminated; else, it generates R 2 and computes sk � h(ID SN ||l), L 3 � h(h(h(ID ia ||R * 1 ||R 2 ))||ID SN || R 2 ), L 4 � h(ID ia ||R 1 ||R 2 ) ⊕ sk, L 5 � R 2 ⊕ ID SNj and L 6 � E l (ID SN ||R 1 ||R 2 ||L 5 ). In this step of the login and authentication phase, the gateway node forwards {L 3 , L 4 , L 5 , L 6 } message towards sensor over a public network channel. (iii) Upon receiving the {L 4 , L 5 , L 6 } message, the sensor node first decrypts L 6 using s to obtain ID SN , R 1 , R 2 and L 5 and computes R * )|| ID SN ||R 2 ) and confirms L 3 / ? � L 3 ; if not matched, termination of the whole process takes place; else, it generates R 3 and computes sk � h(h(ID ia ||R 1 ||R * 2 )|| R 2 ||R 3 ), L 9 � h(sk||R 3 ||R 1 ||R * 2 ), and L 10 � ID ia ||R * 2 || R 2 ||R 3 and sends {L 9 , L 10 } to GW over public channel. (iv) Further, GW computes and calculates R / 3 � L 9 ||R 2 , sk / � h(h(ID ia ||R 1 ||R * 2 )||R 2 ||R / 3 ), L 9 / � h(sk / ||R / 3 || R 1 ||R * 2 ) and confirms L 9 / ? � L 9 ; if found not valid, the process becomes terminated; else, it produces l * and calculates L 11 � E l (h(ID ia ||R 1 ) ⊕ R 2 ), L 12 � h(ID ia ||sk / ||R / 3 ), L 13 � E k (ID SN ||l * ||L 11 ) and transmits {L 11 , L 12 } towards user over a public network channel. (v) e user first decrypts L 11 using s to obtain ID SNj , R 3 , L 10 and calculates R / and verifies L / 11 ? � L 11 and keeps sk, sk / and sk * session shared keys in each peer for secure message transmission among all the participants as shown in Figure 4 , while general framework of the system is shown in Figure 5 . is phase of the protocol is performed between the user's device and gateway node. e following steps are performed in this phase of the protocol. (i) e user provides his/her previous identity ID ia , password PW ia , selects new identity ID ia new and computes new , A 1 , C 1 } towards the gateway node over a secure channel. (ii) Upon receiving the {ID ia , ID ia new , A 1 , C 1 } message, the gateway node computes B 1 * � h(s||l||A 1 ), C 1 * � ID ia ⊕ B 1 * , and confirms C 1 * ? � C 1 ; if not hold, the process is terminated; else, it computes: ||s||l) and stores {V 1 , O 1 , F 1 , h(·)} in its database and transmits it also to the medical device over a secure channel. In this regard, the sensor cancels/evokes/ reissues that the process has been made successfully. (iii) Further, if the medical professional desires to evoke/ cancel/reenter, CA asks for entering the Identity ID ia , and password PW ia of the medical professional and computes: . CA confirms W and Y in its database; if not correct, the process is terminated; else, CA changes the status of a medical professional as inactive. CA also relays the revocation message to the patient to revoke the medical professional's credentials and transmits the changed status back to CA. Finally, CA also updates the gateway node to revoke the specified medical professional. If a user desires to change his/ her password, this protocol provides a password change facility to change the old one with a new one securely. e following steps are performed while changing the password: (ii) Upon receiving the password change message, the medical professional is now able to enter a fresh password PW new ia of his/her own choice, and computes: In this section, the security analysis of the proposed scheme can be performed both formally and informally. e formal security proof will be performed using a BAN logic and ProVerif2.02 and informal operating assumptions. ese are discussed as follows: e shared session key sk has been computed among the user, gateway node, and sensor node for future communication. is subsection is a result of is subsection is added in order to prove the scheme's robustness using BAN [27] . BAN is a logic of belief, and trust was first introduced by Mike Burrows, Martin Abadi, and Roger Needham called BAN. e BAN's reasoning covers the following major issues: (a) Are participants familiar with one another? (b) Do they know if the message is fresh? (c) Is it possible to be confident that a third party did not simply insert incorrect information into the original message? Different rules and their description for the proposed protocol are shown as follows: (1) Message Meaning According to this rule, embedded sensor (user) and gateway node communication are carried out on a secure secret session key. Suppose the user believes that the broadcasting between sensor and gatewaynode is carried out on session private key SK. Both participants see the message M encrypted on key K. In that case, the user also believes in the freshness of message M exchanged between user and gatewaynode. Similar is the case in gateway node (GW); accordingly, if the gateway node believes that the information exchange among GW and SN is performed through a session shared secret key SK, and both participants see the encrypted message M via key K; then GW believes SN once said message M. (2) Message Integrity is rule means that if the user believes that the data transmission over session shared key SK towards gateway node (GW), the message M decrypted with key K, then the user also believes sensor node once said message M. Similarly, suppose a user believes the user that the data transmission over session shared key SK towards gateway node (GW) sees the encrypted message M via key K. In that case, the user also believes the gateway node (GW) once said message M. If GW believes the data transmission towards SN over SK and sees message M via key K, then GW also believes SN once said message M. Similarly, suppose GW believes data transmission towards Sn through session shared key SK and sees message M encrypted over key K, then GW believes SN once said message M. User believes data broadcasting towards Sn over SK and sees the decrypted message M through key Y, then user also believes GW once said message M. Similarly, if GW believes data broadcasting towards SN over Sk and sees the decrypted message M via key Y, then GW also believes SN once said message M. Suppose the user believes that the message received is fresh and GW once said message M, then both user and GW believe that the received message M is also fresh. Similarly, GW believes that M's received message is fresh; SN once said message M then both GW and SN also believe that the received message M is fresh. Suppose both user and GW believe jurisdiction and encryption over key K, then GW believes encryption on message by key K. Similarly, if both user and SN believe message jurisdiction and message encryption on key K, then SN believes encrypted message M through key K. Similarly, if a user and SN jurisdiction over message M, and decrypted message M via key K, then SN believes the decrypted message M via key K. Remark: |≡ Believes, ↔ sk Communication through session key, ⊲ sees, ⇒ SK Jurisdiction, ∼ once said, # freshness, K encryption using K, K−1 Description via K and P/Q, if P then Q. Now, we are using these rules, equations, and definitions for realizing the secure communication between all the participants of the system. ese steps are as follows. Security goals defined for the proposed protocols are as follows: Assumptions stated for the proposed authentication protocol is as follows: Applying the seeing rules S 7 :U ia ⊲GW ⟶ U ia : L 9 , L 10 R 3 , L 11 , L 12 , L 13 } l , so as per S 7 , Asmpt 4 , and L 9 S 8 : U ia |≡GW∼h(s||R 3 ||l), as per Asmpt 2 , S 8 , s, and L 12 , gets S 9 : SN|≡U ia |≡ h(ID ia ||sk / ||R / 3 ) As per Asmpt 6 , S 9 , and L 9 , L 10 S 10 : U ia |≡{L 11 , L 12 , L 13 }, as per Asmpt 4 , S 10 , and sk S 11 : S|≡ SN ↔ sk U ia G 3 Realized As per Asmpt 8 , S 11 , and Jurisdictional rules It means that all the peers successfully authenticate each other and at any stage do not compromise on a session shared secret key (sk). In this subsection of the research paper, a widely used software verification toolkit is used to verify the scheme's confidentiality, authorization, authenticity, and reachability. e ProVerif2.02 simulation code is in appendix A of the paper. It is to mention that the leading entities in the proposed authentication protocol are Certificate Authority (CA), Gateway Node (GW), Sensor Node (SN), and Medical Professional (User). Gateway node, sensor node, and a medical professional will first register with the certificate authority. e intelligent sensors embedded inside the patient's body can transmit data to the gateway node via a wireless medical sensor network. Finally, from the gateway node, with the help of WMSN, the data is transmitted toward medical professionals. e algorithmic overview/representation of the proposed authentication protocol is shown in Algorithm 1. A privileged user, either medical professional or any other administrator cannot extract any credentials for future usage, as each and everything are kept secret from all types of user. e session key is shared securely, and each computation round trip starts from a separate timestamp, in which the other peer verifies before starting of calculation. Similarly, after data transmission, all the credentials are successfully finished due to the log out facility, so no one traces a legitimate user. erefore, the proposed protocol is ensuring anonymity and resists traceability drawbacks. As each session starts with a separate session key and time threshold, if an attacker, for example, desires to send false requests to any peer for a disturbance, he/she fails to do so, because Identity, password, and random keys are much secured, and peers respond only to authenticated credentials. Such requests are denied by peers and stopped for such unlawful activity. erefore, the proposed protocol resists the DoS attack. If two different sensors communicate simultaneously, it will not affect each other due to different identities. Also, the two sessions between the sensor and another user will not act. As each peer computes the session key sk and shares it for future communication, the proposed protocol has no mutual authentication. Attack. e proposed protocol is modified by sensor revocation and patient revocation phases. ese phases successfully log out the requisite user from the process; no credentials were left in either sensor or patient memory. is protocol never allows the evoking entity to start synchronization at any stage in the future. erefore, the protocol resists the main-in-middle attack. Finally, the researchers have the following recommendations: (i) e proposed work can be tested for a deep learning approach for microarray cancer data classification [34] ; graphology based handwritten character analysis for human behavior identification [35] and a deep neural network-based screening model for COVID-19-infected patients using chest X-ray images [36] . (ii) Also, the work done in this research can also be practiced/verified for the rapid COVID-19 diagnosis using ensemble deep transfer learning models from chest radiographic images [37] , visibility improvement, and mass segmentation of mammogram images using quantile separated histogram equalization with local contrast enhancement [38] [39] [40] . In this section of the paper, the proposed authentication scheme's performance analysis is performed by finding its storage overheads, computation, and communication. We analyze each of these features by considering the findings of previous experiment by [41, 42] . Subsequently, it can be compared with some recent and prominent protocols like Kumari et al. [31] , Rathore et al. [32] , Wu et al. [33] , and Amin et al. [5] . e result shows that our scheme is more robust than these schemes. It is worth mentioning that ✓ means that the mentioned attack is "Yes" for the said protocol; it cannot resist and cannot violate the mentioned features, whereas ✖ means that the mentioned security feature is "No" for the said protocol and cannot valid for the mentioned attack, security violation, loophole, etc., as shown in Table 3 . In the work done by [41, 42] , identity occupies 64 bits of space, password 60 bits, timestamp 56 bits, secret key 60 bits, MD5 512 bits, encryption 192 bits, and decryption also 192 bits of memory space. erefore, keeping in view these measures/ calculations and computations, the storage overhead analysis of the proposed authentication protocol is shown in Table 4 . Upon comparing it with Kumari et al. [31] , Rathore et al. [32] , Wu et al. [33] , and Amin et al. [5] , it proves different and fundamental security characteristics/objectives that are higher than those of the mentioned protocols. Graphically, the storage overhead analysis is shown in Figure 7 . if(J 1 * ��J 1 ) then (10) key and computes (11) Transmits Message 2 and computes (14) if(L / 3 ��L 3 ) then (17) key (18) Computes (19) if(L / 13 ��L 13 ) (20) key (21) Return (1) Pass (22) else (23) Return(0), fail (24) end if (25) Return(1) Pass (26) else (27) Return(0), fail (28) end if (29) else (30) Return (1) phase 6t h + 1t ⊕ . e computation time complexity of the proposed scheme is slightly higher compared to [5, 31, 33] , as shown in Table 5 . e protocol presented by [31] is a minimum one-way hash time, but it has maximum exponential execution time, while the XOR time complexity is negligibly equal to zero. Rathore et al. [32] used Advanced Encryption Standard (AES) of key size 512, in which polynomial-time generated the random keys, so its hash value is minimal compared to the proposed and [5] . Similarly, [5] used an extra round trip during the login and authentication phase, which our scheme does not have. erefore, our method consists of a simple hash cryptographic function based; here, it does not affect the computation cost, as shown in Figure 8 . In this modern era, the development of a robust certification environment for the healthcare system gains much attention from researchers, because the intelligent sensors, networkenabled devices (IoMT) and pervasive data acquisition, etc., pushed the healthcare industry to facilitate its patients for diagnoses and remote monitoring. Two things to be focused on for such environment, i.e., information authentication and identification authentication, are challenging, because, without solving these issues and challenges, no one can guarantee secure communication. To ensure data integrity, authorization, nonrepudiation, and user legitimacy and adequately tackle information identification, without a robust authentication protocol, it is not possible. erefore, we have designed improved, lightweight, and robust authentication protocols for IoMT using WMSN. e proposed protocol mitigated all the known flaws noted for [5] and posed in the existing literature. e robustness of the protocol has been verified using a verification toolkit ProV-erif2.00 and BAN logic of belief. In contrast, the performance evaluation result shows that the proposed scheme is fast and secure. e comparison analysis section shows that the proposed protocol is lightweight and balanced with security, often missing in several methods. In the future, researchers plan to design protocols using the cloud, fog, and edge computing using 5G technology. is is ultra-low latency, which may be utilized for ultrahigh reliability in examining a patient's physiological and psychosocial conditions. Also, we plan to discuss the COVID-19 patient X-ray image on a metaheuristic modelbased deep learning/screening. 4500 Kumari et al. [25] Rathore et al. [26] Wu et al. [27] Amin et al. [5] Our Storage overheads in bits Kumari et al. [31] 2976 Rathore et al. [32] 3978 Wu et al. [33] 3968 Amin et al. [5] 2112 Our 2088 ( * -------QUERIES------ * ) query attacker(sk). query attacker(skdash), query attacker(skstr). query attacker(x). query attacker(xstr). query attacker(R 1 ). query attacker(R 2 ). query attacker(R 3 ). query id:bitstring; inj-event(end_SN(IDsn))��>injevent(start_SN(IDsn)). Query id:bitstring; inj-event(end_IDia(IDia))��>injevent(start_IDia(IDia)). (IDia, x, HPW) ) in if Astr � A then let Bstr � xor(h(xor(concat(C, IDia, Astr, HPWstr))) in let F � xor(h(IDia, (concat(xstr, Astr, T 1 ))) in let J 1 � h(concat(IDia, Bstr, R 1 , T 1 )) in let J 2 � xor(h(concat(xstr, T 1 ))) in let L 1 � Enc(xor(concat(J 2 , R 1 , xstr)) in out(ChPub, (IDsn, F, L 1 , T 1 )); in(ChPub, (L 11 : bitstring, L 12 : bitstring, L 13 : bitstring)); let Dec(concat(IDsn, k, L 11 )) in let R2dash � xor(L 11 , h(concat(IDia, R 1 ))) in let R3str � concat(L 10 , Rstr2)) in let Adash � xor(L 13 , h(xor(R2str, R3str))) in let skstr � h(h(concat(IDia, R 1 , R2str), R 2 , R3str)) in let L11dash � h(concat(IDia, skstr, R3str)) in if L11dash � L 11 then event end_Uia(IDia) else 0. let UiaReg � in(ChSec, (IDia:bitstring, HPWia:bitstring)); let HPWia � concat(PWia, Nia) in let A � h(concat(IDia, IDg, x)) in let B � h(concat (IDia, HPWia, x) ) in let C � xor(C, B) in let O � xor(Nia, h(concat(IDsn, x))) in out(CheSec, (A, B, C)); let GW � event start_GW(IDGW); in(ChPub, (IDsn:bitstring, F: bitstring, T 1 : bitstring)); Dec(concat(J 2 , R 1 , xstr)) in let Ostr � xor(R 1 , h(concat(IDsn, xstr))) in if Ostr � O then let IDiastr � xor(F, h(concat(R 1 , Astr, T 1 ))) in let Bstr � h(concat(IDia, A, R 1 )) in let R1str � xor(J 2 , h(concat(Astr, T 1 ))) in let J1str � h(concat(IDiastr, Bstr, R1str, T 1 )) in if J1str � J 1 then let sk � h(concat(IDsn, R 1 )) in let L 3 � h(h(h(concat(IDia, R1str, R 2 , h(concat(IDsn, R 2 ))))) in let L 4 � xor(h(concat(IDia, R 1 , R 2 ), sk)) in let L 5 � sor(R 2 , IDsn) in let L 6 � Enc(concat(IDsn, R 1 , R 2 , L 5 )) in out(ChPub, (L 3 , L 4 , L 5 , L 6 )); in(ChPub, (L 9 : bitstring, L 10 : bitstring)); let Dec(concat(IDsn, R 1 , R 2 ), sk)) in let R3dash � concat(L 9 , R 2 )) in let skdash � h(h(concat(IDia, R 1 , R2str), h(R 2 , R3dash)) in let L9dash � h(concat(skdash, R3dash, R2str)) in if L9dash � L 9 then Let L 11 � xor(h(concat(IDia, R 1 ), R 2 )) in Let L 12 � h(concat(IDia, skdash, R3dash)) in let L 13 � Enc(IDsn, kstr, L 11 )) in out(ChPub, (L 11 , L 12 , L 13 )); event end_GW(IDGW) else 0. process ((!GW) | (!Uia)) Running the code, the listed results are displayed, which shows that the attacker could not trace the session share key SK for reconstruction and secure from cracking, as shown below. RESULT not attacker(sk[]) is true. --Query inj-event(end_Ui(id))��> injevent(start_Ui(id)), Completing... Starting query inj-event(end_Ui(id))��> injevent(start_Ui(id)) RESULT inj-event(end_Ui(id))��> inj-event(start_Ui(id)) is true. --Query inj-event(end_S(id_57))��> injevent(start_S(id_57)). Completing... Starting query inj-event(end_S(id_57))��> injevent(start_S(id_57)) RESULT inj-event(end_S(id_57))��> inj-event(start_S(id_57)) is true. Data Availability e data collected during the data collection phase will be provided upon request to the corresponding authors. e authors declare no conflicts of interest. Internet of medical things (IoMT)-an overview Applied layered-security model to IoMT PMsec: PUF-based energy-efficient authentication of devices on the internet of medical things (IoMT) Detection and recognition of hand gesture for wearable applications in IoMT A robust and anonymous patient monitoring system using wireless medical sensor networks On the security of public key protocols Internet of medical things (IoMT) for orthopedic in COVID-19 pandemic: roles, challenges, and applications IoMT-SAF: internet of medical things security assessment framework Performance analysis of end-to-end security schemes in healthcare IoT Serviceoriented security framework for remote medical services in the Internet of ings environment session resumptionbased end-to-end security for healthcare internet-of-things A secure IoTbased modern healthcare system with the fault-tolerant decision-making process BSN-Care: a secure IoT-based modern healthcare system using body sensor network P2DCA: a privacypreserving-based data collection and analysis framework for IoMT applications A scalable and efficient user authentication scheme for cloud computing environments EPSSHICenabling privacy and security of smart health care system in the cloud Soter: trust discovery framework for internet of medical things (IoMT) Based medical systems for patient's authentication: towards a new verification secure framework using CIA standard Designing a healthcare authorization model based on cloud authentication Privacy-Aware efficient fine-grained data access control in internet of medical things based fog computing Optimized blockchain model for internet of things based healthcare applications BIoMT: blockchain for the internet of medical things Enhanced e-health framework for security and privacy in the healthcare system Fog computing and edge computing architectures for processing data from diabetes devices connected to the medical internet Smart fog: fog computing framework for unsupervised clustering analytics in wearable internet of things Fog computing: helping the internet of things realize its potential Insight into the importance of fog computing on the internet of medical things (IoMT) On the deployment of healthcare applications over fog computing infrastructure Identity and access management with blockchain in electronic healthcare records A dynamic ID-based remote user authentication scheme CSEF: cloud-based secure and efficient framework for smart medical system using ECC Multi-layer perceptron model on chip for secure diabetic treatment An improved and anonymous two-factor authentication protocol for healthcare applications with wireless medical sensor networks Deep learning based search engine for biomedical images using convolutional neural networks Graphology based handwritten character analysis for human behaviour identification Multiobjective evolutionary optimization techniques based hyperchaotic map and their applications in image encryption Novel deep transfer learning model for COVID-19 patient detection using X-ray chest images Visibility improvement and mass segmentation of mammogram images using quantile separated histogram equalisation with local contrast enhancement Deep learning approach for microarray cancer data classification Color image encryption using minimax differential evolution-based 7D hyper-chaotic map A survey of SIP authentication and key agreement schemes Cryptographic hash functions