key: cord-0806773-f3gqgb9z authors: Ikari, Yuji; Yamada, Shinichiro; Ehara, Natsuhiko; Kozuma, Ken; Shinke, Toshiro; Sugano, Teruyasu; Seike, Fumiyasu; Sonoda, Shinjyo; Tazaki, Junichi; Tsuji, Takafumi; Mibiki, Yoshiaki; Muramatsu, Takashi; Morita, Takashi; Sawano, Mitsuaki title: The Japanese Association of Cardiovascular Intervention and Therapeutics position statement on coronary invasive procedures during the COVID-19 pandemic in Japan date: 2021-03-22 journal: Cardiovasc Interv Ther DOI: 10.1007/s12928-021-00767-6 sha: b715931935e13a97177bd8d0fa0e73212f516040 doc_id: 806773 cord_uid: f3gqgb9z nan The coronavirus disease 2019 (COVID-19) has become a global pandemic since the beginning of 2020 and has spread across regions in our nation as well. During the early stage of the pandemic, cardiology practices were forced to limit their quantity of interventional procedures largely due to (1) insufficient understanding of the nature of the disease, (2) inadequate health care system to cope with the risk of COVID-19 infection, and (3) lack of personal protective equipment (PPE) required to reduce the risk of infection for healthcare personnel [1] . In the absence of curative medical treatment, it is crucial for cardiology practices to build strategies that enable the performance of necessary cardiovascular procedures while minimizing the risk of contracting the virus. This position statement has been published to serve this purpose. Please note that this position statement does not intend to overrule already existing local guidelines and rules established by in-house Infection Control Teams and cardiovascular practitioners should follow them accordingly. As a general rule, elective procedures should be performed only for non-COVID-19 patients (SARS-CoV-2 negative). However, it is difficult to completely rule out COVID-19 in all patients in areas or at times of high alert because false negatives have been observed among those who underwent PCR testing. Therefore, it is necessary to prevent infection at the time of the procedure as well. The following are measures to minimize the risk of infection from asymptomatic or mild-symptom COVID-19 patients who may slip through initial screening tests. Individual facilities should determine whether or not the following measures are necessary depending on the level of infection [4] . All medical personnel should wear surgical masks in their facilities at all times. (2) Eye protection with goggles or a face shield The SARS CoV-2 virus enters the human body via the mucosal surface, and there is a possibility of infection through the eyes. If a cardiovascular patient is wearing a surgical mask correctly, protection for the eyes is generally unnecessary, but it is recommended that goggles or a face shield should be worn when dealing with a patient who is not wearing a surgical mask correctly or who may remove it during care. 2. Personal protective equipment in the catheterization laboratory (1) Personal protective equipment for coronary intervention operators 1. PPE should be worn in the same way as instructed for surgical situations. In addition to the surgical gown and gloves, a surgical mask, cap, and goggles (or a face shield) must be worn. 2. The risk of infection is greatest during the undressing of PPE when gowns and gloves are contaminated with SARS CoV-2. Therefore, it is recommended that every healthcare worker in the catheterization lab be familiar with PPE dressing and undressing, and that double-checking during undressing be done by two or more persons. Particular attention should be paid to hand hygiene after PPE undressing by cleansing the operator's hands with alcohol. The correct way to dress and undress PPE can be learned using online learning materials on domestic and foreign infectious diseases society websites. (2) Personal protective equipment for coronary intervention assistants (nurses, medical engineers, etc.) Always wear gloves, surgical mask, cap, goggles, or a face shield. (3) Precautions toward the risk of infection from the patient All patients undergoing procedures must always wear a surgical mask prior to transportation from their ward or upon entering the catheterization lab. Use a nasal cannula or an oxygen mask with a surgical mask if oxygen supply is required. (4) Ventilation and sanitation of the catheterization lab after procedure Routine ventilation and sanitation are not required after the procedure for low probability patients. However, if saliva or other body fluids have attached to the surface of the catheterization lab table, it should be wiped off for sanitation. If a high quantity of aerosol has been generated during a patient's critical state, environmental ventilation and sanitation is required after the procedure. Catheterization labs are generally designed to create a positive air pressure environment to reduce the risk of external pathogens entering the catheterization lab in accordance with current guidelines. Thus, they are not suitable for treating patients with a known or probable infection that can be transmitted via aerosols. The amount of time required for ventilation after procedures on these patients will vary from hospital to hospital and should be estimated as preparation for cases where a high quantity of aerosol emission is expected or has occurred during the procedure. Since emergency procedures need to be pursued within a limited amount of time, preprocedural screening for COVID-19 can be challenging compared to elective procedures. It is important to note that COVID-19 itself can directly cause cardiovascular diseases such as acute coronary syndromes, pulmonary embolisms, and myocarditis. Therefore, patients manifesting sudden onset cardiovascular disease have a higher likelihood for COVID-19 infection; thus, it is difficult to discard the possibility of COVID-19 infection. Emergency procedures for patients with a definite or high probability of COVID-19 infection are recommended to be performed only at institutions with full equipment and personnel to deal with the COVID-19 infection [5, 6] . Emergency procedures can be performed similar to elective procedures under standard precaution if the patient has a low probability of infection. should be performed in the emergency department or the intensive care unit capable of generating a negative air pressure environment with an N95 mask and full PPE before the procedure due to an expected high quantity of aerosol emission which entails a higher risk of infection for healthcare personnel. Intubation should be avoided whenever possible inside the catheterization labs since they are susceptible to infection, especially aerosol-mediated disease. Immediately after intubation, a closed-circuit ventilator with HEPA filters should be used. Use a HEPA filter between the intubation tube and the bag valve if temporary ventilation using a bag valve mask is needed before connection to a ventilator. A lower-than-standard management threshold for intubation is recommended to avoid the risk of intubation or use of non-invasive positive pressure ventilation in the catheterization lab upon the acute onset of respiratory distress. The type of ventilators and their ventilation circuit should be identified since not all ventilators have closed circuits. (2) NPPVs have been used widely for cardiac patients with acute respiratory distress due to their low grade of invasiveness. However, they can cause high-quantity aerosol emission when air leaks from NPPV masks, and large-scale clusters involving NPPV use have been reported previously. For these reasons, NPPVs are recommended not to be used during the COVID-19 pandemic. In a case when NPPVs must be used, healthcare personnel should wear PPE with N95 masks, and the use of NPPVs should be limited within a negative air pressure environment outside the catheterization lab. As stated earlier, definite or highly probable COVID-19 patients are highly advised to be treated only at COVID-19 hospitals even in the case of ACS. The following are the recommended infection control measures that should be taken during care for definite or highly probable COVID-19 patients in the catheterization lab. During a procedure for definite or highly probable COVID-19 patients, the number of healthcare personnel (interventionalist, nurse, medical engineer, radiology technician, etc.) should be limited to the least number necessary for the procedure to minimize the risk of healthcare personnel infection. For example, when more than one interventionalist is available within the facility, limit the interventionalist to one without an assistant during a procedure. All healthcare personnel within the catheterization lab are required to cover themselves with full PPE. Full PPE including an N95 mask, a face shield or goggles, a cap, a gown, and gloves (preferably two pairs of gloves) is mandatory during the procedure. A fit test should be performed prior to wearing an N95 mask, and a seal check must be performed after an N95 mask is worn prior to the procedure. Remove all the equipment unnecessary for the procedure from the catheterization lab to reduce the risk of infection whenever possible. The major infection route of COVID-19 is via droplet contact infection. The use of disposable sheets under the treated patient may be effective to reduce the risk of infection from high concentration contamination in the catheterization lab. Procedures for non-ST elevation myocardial infarction ACS patients are recommended to be performed at the end of the day after all elective procedures, if possible. After a procedure, negative air pressure ventilation, decontamination using either sodium hypochlorite, potassium peroxoacid sulfate-soaked cloth, or 70 degrees or greater ethanol is mandatory for the purpose of terminal cleaning. A short duration of ultraviolet radiation is an alternative method for decontamination. If a certain amount of ventilation can be ensured, the catheterization lab can be used for the next patient after dedicating appropriate time for ventilation and environmental decontamination. The optimal stoppage time for ventilation should be calculated a priori depending on the catheterization lab's ventilation capability. Generally, catheterization labs are designed as level III clean areas that require approximately one hour of ventilation until enough aerosols are removed from the air. If there are more than one catheterization labs within a facility, the catheterization lab to be used for definite or high probability COVID-19 cases should be specified. During the pandemic, there is a high probability that patients requiring urgent medical procedures will be delivered to hospitals without sufficient protection against COVID-19. Therefore, a priori partnership agreements between COVID-19 hospitals and non-COVID-19 hospitals would be crucial for delivering urgent care to these patients, particularly for non-COVID-19 hospitals. Daily increase in the number of COVID-19-infected patients is continually reported as of December 2020. We cannot deny the fact that situations may worsen to the extent that we have observed in the United States and European countries. In the case of a lockdown where the local authority or the government puts restrictions on daily activities of businesses unrelated to basic social infrastructure (e.g., police, fire department, construction, manufacturing, food, pharmacies, or other stores that sell everyday goods), elective procedures are recommended to be postponed to a later time if the patient is in such a condition. Elective procedures are recommended to be postponed to a time when the conditional re-opening of small businesses unrelated to basic social infrastructure or parks is allowed. Nonetheless, the timing of stopping or restarting elective procedures should be thoroughly discussed within each facility, since there is a high demand for human resources during a pandemic. We are beginning to see a path toward a solution with the accelerating amount of research on SARS CoV-2, treatment, and vaccine development against COVID-19. However, the effect of the pandemic is expected to stay for the time being, and may even worsen during the coming months. To maintain the usual care for cardiovascular patients, infection control cannot be ignored. We wish that hospitals all around Japan would refer to this statement and create an in-house infection control guideline customized to their local needs to protect their healthcare personnel and continue usual care for their patients. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/. World Health Organization. Rational use of personal protective equipment (PPE) for coronavirus disease (COVID-19) Interim guidance 19 March. Geneva: World Health Organization Interim Infection Prevention and Control Recommendations for Patients with Suspected or Confirmed Coronavirus Disease 2019 (COVID-19) Catheterization Laboratory Considerations During the Coronavirus (COVID-19) Pandemic: from ACCs Interventional Council and SCAI Interim Guidance for Ambulatory Settings: Screening, Testing, and PPE for COVID-19 EAPCI position statement on invasive management of acute coronary syndromes during the COVID-19 pandemic Management of acute myocardial infarction during the COVID-19 pandemic: a position statement from the Society for Cardiovascular Angiography and Interventions (SCAI), the American College of Cardiology (ACC), and the American College of Emergency Physicians (ACEP) Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations We would like to mention our greatest appreciation toward our fellow infectious disease specialists and outside collaborators for creating this statement during difficult times.Yoshitsugu