key: cord-0806336-0kqdtuxr authors: Waggoner, Jesse J.; Stittleburg, Victoria; Pond, Renee; Saklawi, Youssef; Sahoo, Malaya K.; Babiker, Ahmed; Hussaini, Laila; Kraft, Colleen S.; Pinsky, Benjamin A.; Anderson, Evan J.; Rouphael, Nadine title: Triplex Real-Time RT-PCR for Severe Acute Respiratory Syndrome Coronavirus 2 date: 2020-07-03 journal: Emerg Infect Dis DOI: 10.3201/eid2607.201285 sha: d0c4212533c1f73420b41774701eb3bc90a18b09 doc_id: 806336 cord_uid: 0kqdtuxr Most reverse transcription PCR protocols for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) include 2–3 targets for detection. We developed a triplex, real-time reverse transcription PCR for SARS-CoV-2 that maintained clinical performance compared with singleplex assays. This protocol could streamline detection and decrease reagent use during current high SARS-CoV-2 testing demands. D etection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) typically relies on molecular testing of respiratory tract specimens, although viral RNA can be detected in other specimens (1) . Real-time reverse transcription PCR (rRT-PCR) protocols have been described for SARS-CoV-2, but most involve testing with multiple, singleplex reactions (2) (3) (4) (5) (6) . Such algorithms use large volumes of reagents and limit laboratory testing capacity, both of which have become crucial during the ongoing coronavirus disease pandemic (7) . Multiplex assays are commercially available (8, 9) but require specific platforms and are more expensive than laboratorydeveloped methods. Our objective was to develop an internally controlled, triplex assay to detect SARS-CoV-2 RNA in clinical samples. We initially evaluated 6 individual rRT-PCRs, 3 published by the US Centers for Disease Control and Prevention (2) that target the nucleocapsid (N) gene, N1, N2, and N3; and 3 published by Corman, et al. (4) that target RNA-dependent RNA polymerase (RdRp), envelope (E), and N genes. We performed assays in 20 µL reactions of the Luna Universal Probe One-Step RT-qPCR Kit (New England Biolabs, https://www.neb.com) on a Rotor-Gene Q (QIAGEN, https://www.qiagen.com) by using 5 µL of eluate and our standard cycling protocol (10). We extracted total nucleic acids from samples on an Most reverse transcription PCR protocols for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) include 2-3 targets for detection. We developed a triplex, real-time reverse transcription PCR for SARS-CoV-2 that maintained clinical performance compared with singleplex assays. This protocol could streamline detection and decrease reagent use during current high SARS-CoV-2 testing demands. EMAG (bioMérieux, https://www.biomerieux.com). We compared analytical sensitivity of the assays by using dilutions of 2 SARS-CoV-2 strains, BetaCoV/ Germany/BavPat1/2020p.1 and USA-WA1/2020. The N2 and E-gene assays were the most sensitive singleplex reactions and we noted no substantial change in cycle threshold (C t ) when the assays were combined. We then optimized a triplex assay to include the following targets: N2, which is SARS-CoV-2 specific; E, which also detects SARS-related coronaviruses; and RNase P, which serves as a heterologous, intrinsic specimen control (Appendix Table) . We considered samples positive when they produced exponential amplification curves that crossed the threshold for both N2 and E targets. The dynamic range of both SARS-CoV-2 targets in the triplex assay extended from 8.0 to 2.0 log 10 copies/µL of eluate. We evaluated the lower limit of detection by performing serial dilutions of viral transport media (VTM) from a confirmed case by using VTM from confirmed negative cases. We tested eluates in quadruplicate and calculated RNA concentrations from a 4-point standard curve of quantified ss-DNA (Integrated DNA Technologies, https://www. idtdna.com). The lowest concentration at which all replicates were detected by both targets was 45 copies/µL. When performed in singleplex, the N2 assay detected RNA down to 5 copies/µL, but all replicates had C t >40, and the sensitivity of the E-gene assay did not change. To evaluate specificity, we extracted total nucleic acids from 42 archived nasopharyngeal swab samples in VTM from patients who had laboratoryconfirmed infections with the following viruses: other circulating coronaviruses in the United States (n = 20), influenza (n = 7), parainfluenza (n = 7), human rhinovirus (n = 6), respiratory syncytial virus (n = 3), human metapneumovirus (n = 3), and adenovirus (n = 2). Among the 42 swab samples, 6 had laboratoryconfirmed co-infections with 2 viruses. All samples tested negative for both SARS-CoV-2 targets and positive for RNase P. Finally, we tested nasopharyngeal or oropharyngeal swab samples from 27 patients with a suspected symptomatic SARS-CoV-2 infection (Table) . Ten patients tested positive in the triplex assay. Results demonstrated 100% agreement with either the US Centers for Disease Control and Prevention or Corman et al. (2, 4) protocols performed at CLIA-certified laboratories (Clinical Laboratory Improvement Amendments, We describe the development of an internally controlled triplex SARS-CoV-2 rRT-PCR that targets the N and E genes. The N2 and E-gene targets have proven to be sensitive in singleplex formats and assay performance remained robust to protocol changes we made during optimization in our laboratory. Of note, the triplex SARS-CoV-2 rRT-PCR has been validated only for the instruments and chemistries we describe here. This assay should be thoroughly validated before implementation in other laboratories. Current molecular diagnostic workflows for SARS-CoV-2 contain 2 or 3 viral targets for confirmation (2-6). The triplex SARS-CoV-2 rRT-PCR we describe is consistent with this standard and demonstrated equivalent clinical performance to testing at CLIA-certified laboratories and to the component singleplex assays. In addition, the triplex format streamlines workflow and decreases reagent use. This triplex assay should, therefore, maintain accurate viral detection and improve laboratory capacity to meet the current high demand for testing. Detection of SARS-CoV-2 in different types of clinical specimens Real-time RT-PCR panel for detection 2019-novel coronavirus, instructions for use Molecular diagnosis of a novel coronavirus (2019-nCoV) causing an outbreak of pneumonia Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR Improved molecular diagnosis of COVID-19 by the novel, highly sensitive and specific COVID-19-RdRp/ Hel real-time reverse transcription-polymerase chain reaction assay validated in vitro and with clinical specimens Development of genetic diagnostic methods for novel coronavirus 2019 (nCoV-2019) in Japan SARS-CoV-2 testing cobas SARS-CoV-2. Instructions for use. Roche. 2020 TaqPath COVID-19 Combo Kit. Instructions for use. ThermoFisher Scientific. 2020 Internally controlled, multiplex real-time reverse transcription PCR for dengue virus and yellow fever virus detection We thank Mehul Suthar for providing extracted RNA from cultured SARS-CoV-2 at Emory University; Laurel R. Bristow, Ghina Alaaeddine, and Ariel Kay for specimen collection; and Alejandra Rojas for her helpful comments throughout the course of this project.SARS-CoV-2 RNA was provided by the European Virus Archive Global (EVA-GLOBAL) project, which has received funding from the European Union's Horizon 2020 research and innovation program under grant no. 871029. Samples with other viral pathogens also were collected as part of the RSV in Older Adults and Pregnant women Study Dr. Waggoner is an assistant professor in the Emory University Department of Medicine, Division of Infectious Diseases, Atlanta, Georgia, USA. His research focuses on the development and implementation of new diagnostic methods for viral infections and pathogens that cause an acute febrile illness in the tropics.