key: cord-0802174-tr1ijp93 authors: Huang, Wei-Chang; Lin, Chih-Bin; Chien, Shun-Tien; Wang, Jann-Yuan; Lin, Chou-Jui; Feng, Jia-Yih; Lee, Chih-Hsin; Shu, Chin-Chung; Yu, Ming-Chih; Lee, Jen-Jyh; Chiang, Chen-Yuan title: Performance of Nucleic Acid Amplification Tests in Patients with Presumptive Pulmonary Tuberculosis in Taiwan date: 2022-03-07 journal: Infect Dis Ther DOI: 10.1007/s40121-022-00610-2 sha: 74e0dc24cc4412f0f41e38df2c059bf34d94fde7 doc_id: 802174 cord_uid: tr1ijp93 INTRODUCTION: Several nucleic acid amplification tests (NAATs) for detection of Mycobacterium tuberculosis (TB) complex (MTBC) are available in Taiwan; however, their performances may differ and have not been extensively evaluated. Therefore, we aimed to explore the accuracy of NAATs overall followed by comparison between platforms commonly used in Taiwan. METHODS: This study enrolled presumptive pulmonary TB patients with NAATs throughout Taiwan. The diagnostic performance of smear microscopy and NAATs was assessed using sputum culture as a reference standard. To investigate the performance of NAATs in excluding non-tuberculous mycobacteria (NTM), we quantified the false-positive proportion of NAATs in patients infected with NTM. RESULTS: Of the 4126 enrollees, 860 (20.8%) had positive NAATs. The sensitivity and specificity of NAATs were 83.2% and 96.7%, respectively, compared to 81.5% and 55.3% for smear. There was no significant difference in sensitivity between the NAATs and smear; however, the specificity of smear was significantly lower than that of the NAATs [difference 41.4%, 95% confidence interval (CI) 39.6–43.2%]. There was no significant difference in sensitivity among Roche Cobas Amplicor Mycobacterium tuberculosis assay (Amplicor), Xpert MTB/RIF assay (Xpert) and in-house polymerase chain reaction (in-house PCR) (82.2% versus 83.8% versus 82.4%); however, in-house PCR was significantly less specific than Amplicor (difference 5.3%, 95% CI 2.4–8.2%) and Xpert (difference 5.8%, 95% CI 3.1–8.5%). The sensitivity of NAATs among smear-negative cases was 33.1% (95% CI 26.0–40.3%). In-house PCR had a significantly higher false-positive rate among specimens that were culture positive for NTM than Amplicor (7.7% versus 0.3%; difference 7.4%, 95% CI 3.4–11.5%) and Xpert (7.7% versus 0.7%; difference 7.0%, 95% CI 2.9–11.0%). CONCLUSION: The NAATs overall had a relatively high sensitivity and specificity in detecting MTBC while Amplicor and Xpert performed better than in-house PCR in excluding NTM. Our findings will be useful for the development of national policy. quantified the false-positive proportion of NAATs in patients infected with NTM. Results: Of the 4126 enrollees, 860 (20.8%) had positive NAATs. The sensitivity and specificity of NAATs were 83.2% and 96.7%, respectively, compared to 81.5% and 55.3% for smear. There was no significant difference in sensitivity between the NAATs and smear; however, the specificity of smear was significantly lower than that of the NAATs [difference 41.4%, 95% confidence interval (CI) 39. 6-43.2% ]. There was no significant difference in sensitivity among Roche Cobas Amplicor Mycobacterium tuberculosis assay (Amplicor), Xpert MTB/RIF assay (Xpert) and in-house polymerase chain reaction (in-house PCR) (82.2% versus 83.8% versus 82.4%); however, in-house PCR was significantly less specific than Amplicor (difference 5.3%, 95% CI 2.4-8.2%) and Xpert (difference 5.8%, 95% CI 3.1-8.5%). The sensitivity of NAATs among smear-negative cases was 33.1% (95% CI 26.0-40.3%). In-house PCR had a significantly higher false-positive rate among specimens that were culture positive for NTM than Amplicor (7.7% versus 0.3%; difference 7.4%, 95% CI 3.4-11.5%) and Xpert (7.7% versus 0.7%; difference 7.0%, 95% CI 2.9-11.0%). Conclusion: The NAATs overall had a relatively high sensitivity and specificity in detecting MTBC while Amplicor and Xpert performed better than in-house PCR in excluding NTM. Our findings will be useful for the development of national policy. Keywords: In-house PCR; Nucleic acid amplification; Performance; Roche Cobas Amplicor Mycobacterium tuberculosis assay; Xpert MTB/RIF assay Key Summary Points: Why carry out this study? The performance of the commonly used nucleic acid amplification platforms for detection of Mycobacterium tuberculosis complex has not been extensively evaluated in Taiwan. We hypothesized that different nucleic acid amplification platforms may perform differently in the diagnosis of pulmonary tuberculosis and in excluding nontuberculous mycobacteria. What was learned from the study? The nucleic acid amplification tests overall had a relatively high sensitivity and specificity in detecting Mycobacterium tuberculosis complex. Amplicor and Xpert had better performance than in-house PCR in excluding non-tuberculous mycobacteria. Our results suggest that replacing in-house PCR with other nucleic acid amplification platforms might be of benefit in a realworld setting. Tuberculosis (TB) is an infectious disease caused by Mycobacterium tuberculosis complex (MTBC). Smear-positive pulmonary TB is the most infectious form of TB. The World Health Organization (WHO) announced that an estimated 10 million people had TB and 1.5 million people died from TB globally in 2020, making TB the second leading infectious killer after coronavirus disease 2019 [1] . Moreover, an estimated 3.9% and 21% of new TB cases and previously treated cases, respectively, had rifampin-resistant (RR) or multidrug-resistant (MDR) TB worldwide in 2015 [2] . However, TB incidence has decreased in Taiwan. The Taiwan Centers for Disease Control reported annual notified TB incidence of 72.5 and 33.0 per 100,000 population in 2005 and 2020, respectively. Meanwhile, a reported 2.0% of new TB cases and 7.0% of previously treated cases had RR or MDR TB in 2020 [3] . Nucleic acid amplification (NAA) assays are an important advancement in the diagnosis of TB. Previous studies have demonstrated that NAA tests have better accuracy than smear microscopy and a shorter turnaround time than culture [4] [5] [6] . Several NAA platforms are available in Taiwan, including Roche Cobas Amplicor Mycobacterium tuberculosis assay (Amplicor) (Grenzach-Whylen, Germany) and Xpert MTB/ RIF assay (Xpert) (Cepheid, Sunnyvale, CA, USA). Amplicor targets the 16S ribosomal RNA gene for amplification and detection of MTBC. It can differentiate TB and non-tuberculous mycobacteria (NTM) but cannot detect drug resistance in TB. The Xpert assay amplifies the rpoB gene to detect MTBC and probe for mutations within the 81-bp rifampin resistancedetermining region of the rpoB gene to detect rifampicin resistance. The diagnosis of pulmonary TB begins with identifying individuals suspected of having TB, followed by sputum examinations. NAA tests are usually performed in sputum smear-positive cases to exclude NTM in Taiwan. In 2013, the WHO issued a conditional recommendation that Xpert, rather than conventional smear microscopy and culture, may be used as the initial diagnostic test in all adults and children suspected of having TB [7] . The Taiwan guidelines for the diagnosis and treatment of TB recommend NAA tests together with smear and culture as the initial diagnostic tools in all presumptive TB cases [8] . However, the Xpert test is not yet covered by the Taiwan National Health Insurance system. This is probably because the Xpert assay is more expensive than the other NAA platforms available in Taiwan, even though the Xpert assay is increasingly being used, while use of Amplicor and in-house polymerase chain reaction assays (in-house PCR) is decreasing, at least in part because they are time-consuming and labor-intensive techniques. Moreover, the performance of Xpert has not been comprehensively compared to other NAA platforms in Taiwan. We hypothesized that different NAA platforms may perform differently in the diagnosis of pulmonary TB and in excluding NTM. Therefore, the aim of this study was to extensively investigate the accuracy of NAA tests overall followed by comparing the performance between the commonly used NAA platforms in Taiwan, including in-house PCR, Amplicor and Xpert, in a real-world setting. This multi-center, cross-sectional study was organized by Taipei Medical University-affiliated Wanfang Hospital (TMUWH) as the investigation center. Hospitals taking care of a relatively high number of TB patients throughout Taiwan were invited to participate in this study, including National Taiwan University Hospital, Taipei Veterans General Hospital, Taichung Veterans General Hospital, Ministry of Health and Welfare Taoyuan General Hospital (MOHW-TGH), Ministry of Health and Welfare Chest Hospital (MOHW-CH) and Hualien Tzu Chi Hospital (HTCH). The study was approved by the Institutional Review Boards and Ethics Committees of the participating hospitals (N201903076, 2019-11-007BC, N201903076, IRB108-269-B, IRB_201702013RIND, CE18193A). The need for informed consent was waived because the study was based on a retrospective electronic medical chart review. Patients with presumptive pulmonary TB, defined as those who had both respiratory symptoms and abnormal pulmonary radiographic findings suggesting TB disease, and who underwent NAA tests ordered according to physician judgment from January 2017 to December 2018 at seven participating hospitals, were enrolled in this study. These patients were classified into a frontline NAA group and an add-on NAA group. Frontline NAA was defined as an NAA test requested before or concomitantly with smear microscopy as the initial diagnostic tool; add-on NAA was defined as an NAA test requested after obtaining the results of smear microscopy mainly to exclude NTM. The recommendation in Taiwan was to collect three sputum samples for smear examination for acid-fast bacilli and culture for MTBC for patients suspected of having pulmonary TB although, in fact, some patients did not submit three specimens [8] . The NAA test was encouraged for rapid diagnosis of TB and was highly recommended for positive smear to exclude NTM. Meanwhile, the NAA was done using the same culture sample. Expenditures for all examinations were covered by the national health insurance. Moreover, all of the participating hospitals performed Ziehl-Neelsen stains for smear examination. Among the seven participating hospitals, TMUWH, MOHW-TGH, MOHW-CH and HTCH used both Löwenstein-Jensen medium and Mycobacteria Growth Indicator Tube (MGIT) for culture while the others used MGIT only for culture. Identification was made for any positive culture for mycobacterium to exclude NTM. However, species identification for NTM was not always performed. Particularly, two participating hospitals used Amplicor, three used Xpert, and two used both Xpert and in-house PCR tests. The investigators reviewed and collected data using a standardized questionnaire from electronic medical charts. The collected data included demographic characteristics, type of specimen, date of submitting sputum, date that the results were reported, results of sputum smear microscopy and culture for mycobacteria, type of NAA platform, and the date and results of the NAA tests. The diagnostic performance (sensitivity, specificity and predictive values) of smear microscopy and the NAA tests in the detection of MTBC was assessed using at least one sputum culture positive for MTBC as a positive reference standard and using all sputum cultures negative for MTBC as a negative reference standard [9, 10] . To investigate the performance of the NAA tests in excluding NTM, we performed both patient-and specimen-based analyses to quantify the false-positive rate of the NAA tests in patients infected with NTM. In patient-based analysis, any positive NAA test in patients infected with NTM was classified as being false positive, even if the specimen that was tested positive for NAA and the specimen that was culture positive for NTM were different specimens. In specimen-based analysis, a positive NAA test in patients infected with NTM was classified as being false positive only if the specimen that was tested positive for NAA and the specimen that was culture positive for NTM were the same specimen. We did not know the number of Xpert, Amplicor and in-house PCRs performed in the participating hospitals. Thus, we only estimated the total sample size of NAA tests required based on the advice of Bujang et al. [11] . Assuming the prevalence of TB among those who had NAA tests was 5%, the required sample size for 80% power to detect NAA with a sensitivity of 70% or 80% was 3100 or 2140, respectively. We thus planned to assess 4000 or more individuals with NAA tests to ensure that we had a sufficient sample size to assess the performance of the NAA assays. Electronic data were managed using a password protected personal computer at TMUWH. Stata Version 15 (Stata Corp LP, College Station, TX, USA) was used for data analysis. Categorical variables were tabulated as frequency and percentage. We computed and compared differences and 95% confidence intervals (CIs) of the differences in sensitivity, specificity and falsepositive rate among NTMs between the different platforms using the chi-squared test. Figure 1 shows that a total of 4271 presumptive TB patients underwent sputum NAA tests for There was no significant difference in sensitivity between Amplicor and Xpert (difference 1.6%, 95% CI -7.2-4.0%), between Amplicor and in-house PCR (difference 0.2%, 95% CI -8.4-7.9%) or between Xpert and in-house PCR (difference 1.4%, 95% CI -6.0-8.7%). However, the specificity of in-house PCR was significantly lower than that of Amplicor (difference 5.3%, 95% CI 2.4-8.2%) and Xpert (difference 5.8%, 95% CI 3.1-8.5%). Of the 4096 patients with smear and culture results, 2161 (52.8%) were smear positive, of whom 731 (33.8%) were culture positive for TB and 880 (40.7%) were culture positive for NTM. In addition, 1935 (47.2%) were smear negative, of whom 166 (8.6%) were culture positive for TB and 206 (10.6%) were culture positive for NTM. The sensitivity of smear microscopy in the detection of MTBC was 81.5% (95% CI 79.0-84.0%), with a specificity of 55.3% (95% CI 53.6-57.0%), positive predictive value (PPV) of 33.8% (95% CI 31.8-35.8%) and negative predictive value (NPV) of 91.4% (95% CI 90.2-92.7%). There was no significant difference in sensitivity between NAA and smear tests (difference 1.7%, 95% CI -1.8-5.2%); however, the specificity of smear tests was significantly lower than that of NAA tests (difference 41.4%, 95% CI 39.6-43.2%). Of the 4126 patients with NAA tests, 1100 (26.7%) were infected with NTM, including 44.6%, 20.2% and 31.5% of those who underwent Amplicor, Xpert and in-house PCR tests, respectively (Table 5 ). In patient-based analysis, the false-positive rate of NAA among the patients infected with NTM was 3.2%, including 0.8% for Amplicor, 2.7% for Xpert and 10.3% for in-house PCR. In specimen-based analysis, the false-positive rate of NAA tests was 1.6%, (Table 5 ). In-house PCR had a significantly higher false-positive rate among the specimens that were culture positive for NTM than Amplicor (difference 7.4%, 95% CI 3.4-11.5%) and Xpert (difference 7.0%, 95% CI 2.9-11.0%). Our results revealed that the NAA tests had relatively high sensitivity, specificity, PPV and NPV. In addition, the performance of frontline NAA and add-on NAA tests did not differ significantly, except that the sensitivity of frontline Amplicor was lower than that of add-on Amplicor. There was no significant difference in sensitivity between the NAA tests and smear microscopy; however, the specificity of smear microscopy was substantially lower than that of the NAA tests. The three NAA platforms that we evaluated had a relatively low sensitivity in patients with smear-negative pulmonary TB. Furthermore, in-house PCR had a significantly lower specificity compared to Amplicor and Xpert, in part because in-house PCR had a relatively high false-positive rate among the patients infected with NTM. Several studies have validated the performance of Amplicor, Xpert and in-house PCR in the diagnosis of pulmonary TB in different settings [12] [13] [14] [15] [16] [17] , providing evidence to support the use of NAA tests as an initial diagnostic test for the rapid detection of pulmonary TB. Amplicor has been used in Taiwan for 2 decades. It can be loaded with 24 samples for simultaneous amplification and is usually used in laboratories with a relatively high volume of tests. Eing et al. reported that, compared to in- reported that the sensitivity of in-house PCR was higher than that of Amplicor in hospitalized patients [18] . However, we found that Amplicor had a similar sensitivity and better specificity compared to in-house PCR in our settings. Amplicor and Xpert have rarely been compared. Patel et al. compared Amplicor and Xpert for the diagnosis of TB meningitis and reported that they had similar sensitivity and specificity [19] . Antonenka et al. reported that Xpert and Cobas Taqman MTB assay had a similar performance in detecting MTBC in respiratory specimens [20] . Our results revealed that Xpert and Amplicor had similar sensitivity and specificity. Moreover, both Amplicor and Xpert had better specificity than in-house PCR for the diagnosis of pulmonary TB, while the sensitivity between these two platforms was similar. The sensitivity of smear microscopy in the detection of MTBC was relatively high (81.5%) in our study samples, and there was no significant difference in sensitivity between the NAA and smear tests. This likely was largely because a relatively high proportion of the NAA tests was performed as an add-on test for positive smear to exclude NTM, which may have introduced selection bias. However, the specificity of smear tests was significantly lower (55.3%) than that of the NAA tests. We have been conducting a prospective randomized study on NAA tests in the diagnosis of pulmonary TB in Taiwan, which may provide additional insights into this issue. The relatively low sensitivity of NAA tests for smear-negative specimens (33.1%) is a concern and is not sufficiently reliable to exclude TB. This finding is likely because there were very few bacilli in the respiratory samples and is consistent with a previous study [21] . Roche Diagnostics (Rotkreuz, Switzerland) has replaced the Cobas Amplicor MTB test with the Cobas TaqMan MTB test, which has a better specificity than the Cobas Amplicor MTB test [22] . However, the sensitivity of the Cobas TaqMan MTB test for smear-negative specimens remains unsatisfactory [21] . Cepheid (Sunnyvale, CA, USA) developed the Xpert MTB/RIF Ultra (Xpert Ultra) to overcome the limitations of the Xpert MTB/RIF assay [14] . Dorman et al. conducted a prospective multicenter diagnostic accuracy study comparing the diagnostic performance of Xpert Ultra with that of Xpert MTB/RIF and concluded that the sensitivity of Xpert Ultra was superior to that of Xpert MTB/ RIF in patients with paucibacillary TB and in patients with human immunodeficiency virus infection [15] . However, this increase in sensitivity of Xpert Ultra came at the expense of a decrease in specificity, especially in patients with a previous history of anti-TB treatment [15] . Further studies are needed to investigate whether the sensitivity of Xpert Ultra is superior to that of Xpert MTB/RIF in Taiwan. Recently, the frequency of discovery of NTM has increased in Taiwan. One previous study conducted in northern Taiwan showed that NTM accounted for 56.9% of cultures testing positive for mycobacteria during 2000-2012, while another Taiwanese multicenter study found that the incidence rate of NTM lung disease was 46.0 episodes per 100,000 hospitalbased patient-years during 2010-2014 [23] [24] [25] . Therefore, NAA tests are increasingly used to rapidly differentiate TB and NTM in patients with a positive-smear result in Taiwan. Our results revealed that Amplicor and Xpert performed similarly well in excluding NTM with a relatively low false-positive rate. However, inhouse PCR had a significantly higher false-positive rate among patients infected with NTM compared to Amplicor (7.7% versus 0.3%) and Xpert (7.7% versus 0.7%). This is consistent with the findings of previous reports in which the false-positive rate of in-house PCR (12.1%, 7/58) among subjects with a positive culture for NTM was higher than that of Amplicor (6.9%, 4/58) and Xpert (0.8%, 1/122) [18, 19] . This highlights discrepancies between the laboratory practice of in-house PCR, the National Committee for Clinical Laboratory Standards guidelines, and the manufacturers' recommendations. Taken together, these findings suggest that it may be beneficial to replace in-house PCR with other NAA platforms in clinical practice. Of note, Xpert may report false-positive results for five NTM species (M. abscessus, M. marinum, M. smegmatis, M. phlei and M. aurum) [26, 27] . This study has several strengths. It was implemented in seven hospitals throughout Taiwan with a relatively high number of TB patients. This allowed us to enroll a large number of participants, which is representative of our setting. Furthermore, the real-world data used in this study reflect clinical practice, and thus our findings will be useful for the development of national policy. There are also several limitations to this study. A substantial proportion of the NAA tests were add-on tests and thus may have introduced a selection bias toward a relatively high sensitivity of smear microscopy in the detection of MTBC. Moreover, there was heterogeneity of laboratory methods and regulations between the hospital laboratories. We did not include non-respiratory specimens, thus our findings may not be generalizable to patients suspected of having extrapulmonary TB. Also, some clinical information was not collected, and we were not able to explore the causes of false-positive NAA results. Lastly, NTM species identification was not performed in all subjects infected with NTM because of the retrospective study design. Therefore, we were not able to investigate the complete profile of NTM species that caused false-positive NAA results. Previous studies have found that routine NAA testing for all specimens from patients suspected of having TB in a low prevalence setting is not as cost-effective as that in high TB burden countries [28] [29] [30] . Our findings showed that Amplicor and Xpert had a similar performance for diagnosing pulmonary TB. However, Amplicor requires multiple samples per run and does not detect rifampicin resistance in TB. Xpert is more expensive than Amplicor, but it can manage specimens individually and can detect rifampicin resistance. In-house PCR had a lower specificity and a relatively high falsepositive rate in excluding NTM in this study, and thus it may not be a good option until its performance has been improved. Taiwan has a medium burden of TB (annual reported TB incidence of 33.0 per 100,000 population in 2020) and a relatively low prevalence of rifampicin resistance (2.0% among new TB cases and 7.0% among previously treated cases had RR or MDR TB in 2020) [3, 8] . In laboratories with a relatively high volume of tests per day, whether first performing Amplicor as the initial diagnostic test followed by Xpert for Amplicorpositive specimens to detect rifampicin resistance would be more cost-effective than the use of Xpert as the initial diagnostic test needs to be investigated. In contrast, for hospitals that manage a relatively low number of TB patients, using Xpert rather than Amplicor to manage specimens individually would likely be a better option to achieve a shorter turnaround time. Although NAA tests had a relatively high sensitivity and specificity in detecting MTBC in our settings, the sensitivity values of Amplicor, Xpert and in-house PCR in the detection of TB among smear-negative pulmonary TB cases were all relatively low. Amplicor and Xpert performed better than in-house PCR in excluding NTM, suggesting that it might benefit from replacing in-house PCR with other NAA platforms in a real-world setting. the work as a whole, and have given their approval for this version to be published. Author contributions Chen-Yuan Chiang designed the study. All authors performed the study and collected, analyzed and interpreted the data. Wei-Chang Huang, Chih-Bin Lin and Shun-Tien Chien wrote the paper. Chen-Yuan Chiang supervised the study. All authors read and approved the final manuscript. Disclosures Wei-Chang Huang, Chih-Bin Lin, Shun-Tien Chien, Jann-Yuan Wang, Chou-Jui Lin, Jia-Yih Feng, Chih-Hsin Lee, Chin-Chung Shu, Ming-Chih Yu, Jen-Jyh Lee and Chen-Yuan Chiang all have nothing to disclose. Compliance with ethics guidelines The study was approved by the Institutional Review Boards and Ethics Committees of the participating hospitals, including National Taiwan University Hospital, Taipei Veterans General Hospital, Taichung Veterans General Hospital, Ministry of Health and Welfare Taoyuan General Hospital, Ministry of Health and Welfare Chest Hospital and Hualien Tzu Chi Hospital (N201903076, 2019-11-007BC, N201903076, IRB108-269-B, IRB_201702013RIND, CE18193A) and implemented in accordance with the Declaration of Helsinki. The need for informed consent was waived because the study was based on a retrospective electronic medical chart review. Data Availability The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request. Open Access. This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/bync/4.0/. Geneva: World Health Organization Epidemiology of drugresistant tuberculosis Availability of an assay for detecting Mycobacterium tuberculosis, including rifampin-resistant strains, and considerations for its use -United States Impact of GeneXpert MTB/RIF on patients and tuberculosis programs in a low-burden setting a hypothetical trial The health-system benefits and cost-effectiveness of using Mycobacterium tuberculosis direct nucleic acid amplification testing to diagnose tuberculosis disease in the United States Automated Real-Time Nucleic Acid Amplification Technology for Rapid and Simultaneous Detection of Tuberculosis and Rifampicin Resistance: Xpert MTB/RIF system for the diagnosis of pulmonary and extrapulmonary TB in adults and children. Policy update.: World Health Organization wan). Taiwan Guidelines for TB Diagnosis & Treatment (6E). Centers for Disease Control, Ministry of Health and Welfare Diagnosis of smear-negative tuberculosis is greatly improved by Xpert MTB/ RIF Yield of serial sputum specimen examinations in the diagnosis of pulmonary tuberculosis: a systematic review Requirements for Minimum Sample Size for Sensitivity and Specificity Analysis Clinical evaluation of the automated COBAS AMPLICOR MTB assay for testing respiratory and nonrespiratory specimens Comparison of Roche Cobas Amplicor Mycobacterium tuberculosis assay with in-house PCR and culture for detection of M. tuberculosis The New Xpert MTB/RIF Ultra: Improving Detection of Mycobacterium tuberculosis and Resistance to Rifampin in an Assay Suitable for Point-of-Care Testing Xpert MTB/RIF Ultra for detection of Mycobacterium tuberculosis and rifampicin resistance: a prospective multicentre diagnostic accuracy study Added value of Xpert MTB/RIF ultra for diagnosis of pulmonary tuberculosis in a low-prevalence setting Performance of Xpert MTB/RIF, Xpert ultra, and Abbott RealTime MTB for diagnosis of pulmonary tuberculosis in a high-HIV-burden setting Diagnosis of pulmonary tuberculosis using PCR assays on sputum collected within 24 hours of hospital admission Performance of the Xpert MTB/RIF assay for the diagnosis of pulmonary tuberculosis and rifampin resistance in a low-incidence, high-resource setting Comparison of Xpert MTB/RIF with ProbeTec ET DTB and COBAS TaqMan MTB for direct detection of M. tuberculosis complex in respiratory specimens Evaluation of the Cobas TaqMan MTB test for the detection of Mycobacterium tuberculosis complex according to acid-fast-bacillus smear grades in respiratory specimens Evaluation of Cobas TaqMan MTB for direct detection of the Mycobacterium tuberculosis complex in comparison with Cobas Amplicor MTB Pulmonary infection and colonization with nontuberculous mycobacteria Epidemiology and predictors of NTM pulmonary infection in Taiwan-a retrospective, five-year multicenter study Nontuberculous mycobacterial lung disease epidemiology in Taiwan: a systematic review Assessment of laboratory performance of nucleic acid amplification tests for detection of Mycobacterium tuberculosis Misdiagnosis of tuberculosis associated with some species of nontuberculous mycobacteria by GeneXpert MTB/RIF assay Economic evaluation of the use of PCR assay in diagnosing pulmonary TB in a lowincidence area Cost-effectiveness of Xpert MTB/RIF and investing in health care in Africa The cost effectiveness of nucleic acid amplification techniques for the diagnosis of tuberculosis Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations We thank the participants of the study and Dr. Gwan-Han Shen, who supervised Laboratory No. 114 at Taichung Veterans General Hospital and passed away in 2014. We hold you dear in our memory. Funding This work was supported by the Ministry of Science and Technology, Taiwan (MOST 108-2314-B-038-122). The Rapid Service Fee was funded by the Taichung Veterans General Hospital, Taichung, Taiwan.Authorship All named authors meet the International Committee of Medical Journal Editors (ICMJE) criteria for authorship for this article, take responsibility for the integrity of