key: cord-0798754-2xe2pddk authors: Wang, Qun; Lung, David Christopher; Chan, Pak-To; Jia, Wei; Dung, Chung-Hin; Miao, Te; Huang, Jianxiang; Chen, Wenzhao; Wang, Zixuan; Leung, Kai-Ming; Xu, Pengcheng; Lin, Zhang; Wong, Daniel; Tse, Herman; Ying Wong, Sally Cheuk; Choi, Garnet Kwan-Yue; To, Kelvin Kai-Wang; Cheng, Vincent Chi-Chung; Yuen, Kwok-Yung; Li, Yuguo title: High attack rate in a Tong Lau house outbreak of COVID-19 with subdivided units in Hong Kong date: 2022-02-11 journal: Interface focus DOI: 10.1098/rsfs.2021.0063 sha: 2cac263b100043379eb6dc11ca5fb2895572883d doc_id: 798754 cord_uid: 2xe2pddk Poor housing conditions are known to be associated with infectious diseases such as high Coronavirus disease 2019 (COVID-19) incidences. Transmission causes of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in poor housing conditions can be complex. An understanding of the exact mechanism of transmission can help to pinpoint contributing environmental issues. Here, we investigated a Hong Kong COVID-19 outbreak in early 2021 in four traditional Tong Lau houses with subdivided units. There are more than 80 subdivided units of less than 20 m(2) floor area each on average. With a total of 34 confirmed COVID-19 cases, the outbreak had an attack rate of 25.4%, being one of the highest attack rates observed in Hong Kong, and ranked among the highest attack rates in reported outbreaks internationally. Tracer gas leakage and decay measurements were performed in the drainage system and in the subdivided units to determine the transport of infectious aerosols by the owner-modified sophisticated wastewater drainage pipe networks and the poor ventilation conditions in some subdivided units. The results show that the outbreak was probably due to multiple transmission routes, i.e. by the drainage pipe spread of stack aerosols, which is enhanced by poor ventilation in the subdivided units. Underprivileged communities have been hit the hardest in the Coronavirus disease 2019 (COVID-19) pandemic [1, 2] , where patients from poor housing conditions were associated with higher COVID-19 incidence and mortality [3] . The exact environmental conditions that can lead to the transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in poor housing conditions remain unknown. As an example, Hong Kong has around 200 000 people living in so-called subdivided units (also referred to as subdivided flats) of 6-10 m 2 or even less [4, 5] . These subdivided units are formed by dividing a small flat into several tiny units for rental. Each subdivided unit has its own toiletcum-bathroom for privacy [6] . In Hong Kong, these subdivided units are usually built in the so-called Tong Lau (literally means 'Chinese building') before the 1960s, which is like a low-rise tenement with one flat on each floor. These flats generally share an entrance stairway access. Tong Lau is one of the three main types of housing, and other two are public (rental) housing (44.8% of the population) and private housing (54.6% of the population) in Hong Kong. Tong Lau is known to be a more suboptimal environment than the other two types of housing [7] , which is made worse by the increasing number of subdivided units following the housing shortage. The subdivided units also experience poor air quality due to overcrowding and insufficient ventilation [4, 8] . Access to these subdivided units for field study is generally very difficult. A large COVID-19 outbreak occurred in early January 2021 in four Tong Lau houses, involving more than 80 subdivided The residents from the four Tong Lau houses were sent to quarantine centres for two-week isolation from 15 January 2021. Following a disinfection campaign in the buildings and an approval by the Centre for Health Protection (CHP), our research team gained access to carry out on-site tracer gas studies with the consent of residents during the last 2 days of the quarantine period, which was preceded by two site visits 2 days earlier. We first obtained the dates of symptom onset and sub-unit addresses of the confirmed COVID-19 cases from the CHP, Department of Health and local media (table 1) . We also obtained the building data, original site plan (figure 1) and plumbing layout from the Buildings Department of Hong Kong. The owner or residents subdivided each flat into smaller units for rental. The exact time of subdivision is unknown; however, the interior conditions of the subdivided units were found to be decent and clean. Each subdivided unit has its own toilet-cum-bathroom, which is confirmed by our visits to five units. The subdivided unit floor plan, and the new drainage system drawings are not available. We had access to the common semi-open corridors of the four Tong Lau houses, some shared interior corridors of subdivided units, and only 5 subdivided units. According to our site visits, each flat is subdivided into 3-4 units (subdivided units) with two flats being subdivided into 6 or 7 units (table 2 and figure 1 ). An approximate floor plan of typical subdivided units on the 5th floor of no. 26 Reclamation Street is shown in figure 1a . These subdivided units are numbered, e.g. unit 3A (no. 20) is the subdivided unit A of the 3rd-floor flat in no. 20 Reclamation Street. Tracer gas (SF 6 ) measurements were conducted on 27-28 January 2021 just before the residents returned from their quarantine centres. Tang et al. [9] and Zhang et al. [10] found that when the airflow removal dominates, a tracer gas can mimic well the dispersion of airborne particles ( particularly exhaled droplet nuclei) smaller than 5-10 μm as the effects of settling removal of these fine particles are relatively small. We monitored the tracer gas concentration in five infected units, i.e. Unit 1D (no. 26), Unit 5C (no. 26), Unit 5D (no. 26), Unit 3A (no. 20) and Unit 5B (no. 20), façades and roof vents by using a 24-channel multipoint sampler, a photoacoustic gas monitor (Innova 1412i and 1409, LumaSense Technologies, Ballerup, Denmark) and a 6-channel multipoint sampler and a multi-gas monitor (type 1303 and 1302, Brüel & Kjaer, Naerum, Denmark). To achieve a higher temporal resolution, we used one sampling point of each of the two sets of instruments in each flat. Before the test was started, we sealed the toilet door of units, the water basins with PVC sheets and tapes. For safety concerns, although the CHP health officers had disinfected the environment, we poured disinfectant into the sink and floor drain during the measurements, thereby the U-trap of the floor drain should be functioning during our experiment. Three sets of tracer gas experiments were performed. First, the tracer gas was injected into the drainage stack via the toilet in Unit 5D (no. 26) or Unit 3A (no. 20) at a flow rate of 0.2 l min −1 with the exhaust fan on or off. Second, the tracer gas was injected into the drainage stack via the toilet in Unit 3A (no. 20) at a flow rate of 0.2 l min −1 , while warm water was being added to the drainage pipe to simulate when a resident takes a shower under the conditions of the exhaust fan on. Third, the tracer gas was released in Unit 5D (no. 26) to study the horizontal transmission. The association between the distribution pattern of the infected units and the leaked tracer gas measurement is then discussed. Additionally, ventilation rates were estimated in Unit 5D (no. 26), while the tracer gas was released in Unit 5D (no. 26) with the exhaust fan off. The air change rate was obtained from the tracer gas decay curve. All of the confirmed cases were admitted to a public hospital managed by the Hospital Authority in Hong Kong. Patients were isolated in an airborne isolation room, and a real-time reverse transcription polymerase chain reaction assay was performed, as described previously [11] . SARS-CoV-2 genome sequencing and subsequent sequence analysis were performed, as described previously [12] , on laboratory-confirmed COVID- 19 figure S4 ), and all residents in the four Tong Lau buildings also share the same stairwell for entry. Authorities first issued a compulsory testing order for 26 Reclamation Street on 8 January 2021, and then extended it to cover 20, 22 and 24 Reclamation Street 4 days later after more cases were identified. On 15 January, the Department of Health issued a quarantine order to all other residents of the four buildings and transferred them to quarantine centres. A total of 100 residents were evacuated to the quarantine centres, and it is unknown if any other residents left the buildings before the quarantine. The total number of residents is estimated to be 134. No access to the buildings was allowed without approval during the quarantine period. Table 1 figure 4 . Sequence analysis confirmed that the viral genome sequences were essentially identical in 17 cases, whereas sequences from the remaining six cases contained one to two additional nucleotide substitutions. Overall, these results support a point source in the cluster. Lack of drainage system drawings and unique design of interior subdivided units causes enormous challenges for our royalsocietypublishing.org/journal/rsfs Interface Focus 12: 20210063 seemed to be used for some wastewater discharge (electronic supplementary material, figure S2 ). The index patient lived in Unit 6A (no. 26), but unfortunately, we were unable to access the unit. Instead, we had to inject the tracer gas into the drainage pipe via the toilet of Unit 5D (no. 26) which is close to the index unit. To explain the vertical cluster of confirmed cases, we monitored the tracer gas concentration in Unit 1D (no. 26) and Unit 5C (no. 26). For the horizontal cluster of confirmed cases, we monitored tracer gas concentration in Units 5D (no. 26) and 5C (no. 26). For 20 Reclamation Street, we injected tracer gas into the drainage pipe via the toilet of Unit 3A (no. 20) and monitored the tracer gas concentration in Unit 5B (no. 20) and roof vent. The sampling locations were set at around 10 cm above the floor drain of the toilet and near the roof vent. [13, 14] , the major vertical spread in the vertical cluster was likely due to the drainage system. When we turned on the exhaust fan of Unit 5B (no. 20) and injected tracer gas into the drainage pipe via the toilet of Unit 3A (no. 26), the peak concentration near the roof vent was around 49.25 ppm, a much lower value than 233.64 ppm from the previous test under the same condition. It may be modulated by the temperature difference in the air between the drainage system and the outdoor; therefore, we added warm water through the floor drain (the same drain was used when the residents took showers) to find out its effect on the vertical spread of tracer gas. Figure 6 shows the temporal variation of concentration in the bathroom of Unit 5B (no. 20) and roof vent for the building at no. 20 Reclamation Street. An obvious fluctuating pattern of concentration was detected. The concentration dropped to around 0.02 ppm from 13.03 to 13.16, even with continuous dosing. When we started adding 2 l of 43.4°C warm water every 5 min from 13.27 through the floor drain of Unit 3A (no. 20), the concentration first dropped slightly, and then increased to around 1.1 ppm at peak. Notice this increase in concentration occurred when dosing had already been stopped. After tracer gas had been injected into the drainage pipe, a high concentration near the roof vent persisted with a small fluctuation. Discharging warm water increased air temperature in the drainage pipes, and increased stack pressure leading to more SF 6 detected in the flat and near the roof vent. We can imagine that in such crowded living conditions, the heat release due to shower warm water would be large enough to cause a strong buoyancy effect in the drainage stack. In terms of the horizontal cluster, all units on the 6th floor at 26 Reclamation Street were infected. Three of four units on the 5th floor were also infected. Both stack aerosols from the toilet of infected/index case units and respiratory aerosols from the infected/index case units could spread into the adjacent units as these subdivided units share the same corridor (figure 1a). As we were releasing tracer gas in Unit 5D (no. 26), we monitored an above-background-level concentration in Unit 5C (no. 26). Figure 7 shows the detection of a tracer elevation on Unit 5C (no. 26) when releasing the tracer gas in the adjacent Unit 5D (no. 26). The doors and windows were closed, exhaust fans were off, and no one accessed the units during the measurement. This indicated that some gas escaped into the adjacent Unit 5C (no. 26) from some unnoticed leakages. The non-approved drainage pipe and kitchen exhaust ducts might be flawed due to space constraints (e.g. electronic supplementary material, figure S3 ). For all pipes or ducts to be directed to outside, some may have to cross the wall connecting any two units; for example, kitchen air ducts and toilet exhaust fans in Unit 5C (no. 26) were installed above the toilet of 5C (no. 26) and 5D (no. 26), hidden in ceiling panels. The air may be leaked to Unit 5C (no. 26) if there is a gap between the flexible pipe and wall or if the exhaust pipes of the subdivided units were inter-connected. The measured data thus may have revealed a potential inter-unit spread. Under such overcrowded circumstances, the ventilation rate of the subdivided units may have also played a role in the infection transmission among these adjacent units. Therefore, we used a tracer gas concentration decay method to estimate the air exchange rate per hour (ACH) in these units by royalsocietypublishing.org/journal/rsfs Interface Focus 12: 20210063 releasing the tracer gas in Unit 5D (no. 26) with windows closed. An electric fan was placed in Unit 5D (no. 26) to promote air mixing for a more uniform concentration distribution. Once a high concentration of tracer gas was detected in the dosing unit, the injection was stopped, and the concentration variation of the tracer gas in both Unit 5D (no. 26) and Unit 5C (no. 26) was continuously monitored. The sampling points were located about 1.5 m from the floor in the living room of Unit 5D (no. 26) and Unit 5C (no. 26). Figure 8c shows the concentration decay in Unit 5D (no. 26) and Unit 5C (no. 26). After SF 6 was injected for 16 min, the concentration reached a relatively steady state (approx. 190 ppm in Unit 5D (no. 26)). We also measured a relatively high concentration (approx. 24 ppm, whereas the background level on the measurement day is less than 0.1 ppm) in Unit 5C (no. 26), which indicates the tracer gas leaks to the adjacent Unit 5C (no. 26) from Unit 5D (no. 26) even with the windows and doors in both units closed (similar results in figure 7) . The SF 6 concentration decayed exponentially to nearly 0.1 ppm after 10 h for Unit 5D (no. 26) and 4 h in Unit 5C (no. 26). The tracer decay data of Unit 5D (no. 26) were used to determine the ACH with the concentration decay method, as the tracer gas distribution should be relatively uniform in the dosing unit when the concentration reaches a steady state with the air mixing set-up. An air exchange rate of 0.99 ACH has been found in Unit 5D (no. 26). The room volume of Unit 5D (no. 26) is estimated to be 36.45 m 3 (floor area 13.5 m 2 × height 2.7 m), so that the estimated 'ventilation' rate is only 9.9 l s −1 for Unit 5D (no. 26), which includes transported air from neighbouring rooms. We were unable to repeat the air exchange rate measurement due to time constraints. The Tong Lau houses have a special hopper head design, and its potential effect on aerosol spread was also investigated. We focused on 26 Reclamation Street, and the design of the drainage system is shown in the electronic supplementary material, figure S2 . As the pipe of the hopper head and drainage stack are connected at the bottom, we injected tracer gas into the drainage stack via the toilet of Unit 5D (no. 26) and monitored the concentration near the hopper head on the 2nd, 3rd and 4th floors and the roof vent pipe. Without adding warm water to the drainage stack via the floor drain of Unit 1D (no. 26), the concentration near the hopper head on the 2nd floor subsequently increases after dosing began, although with a small fluctuation. The average concentration near the hopper head on the 2nd floor was royalsocietypublishing.org/journal/rsfs Interface Focus 12: 20210063 around 0.3 ppm. For the concentration near the hopper heads on the 3rd and 4th floors, only an abrupt increase was detected at around 16.20 (figure 9); at other time slots, the concentration remained relatively low (around 0.01 ppm). After adding 2 l of warm water at an average temperature of 42.5°C to the drainage stack, the concentration dramatically increased to a higher level (e.g. the peak concentration was 499. 8, 44.9 and 19.8 ppm on the 2nd-, 3rd-and 4th-floor hopper heads, respectively). Such a design may increase the infection risk to the surroundings. An unexpected phenomenon was detected on the second day of measurement. Following our plan, we conducted the tracer gas measurement by releasing the tracer gas in no. 26 Reclamation Street on the first day and no. 20 Reclamation Street on the second day. There was no tracer gas released into the drainage system of no. 20 Reclamation Street; however, at the beginning of the first test before releasing tracer gas into the drainage system of no. 20 Reclamation Street on the second day, we detected a relatively high tracer gas concentration (0.5-1.0 ppm) in its vent pipe. Although the four houses of nos. 20-26 have their individual drainage system, these drainage stacks connect at the bottom before discharge into the manhole. The tracer gas released in the drainage system at no. 26 Reclamation Street on the first day remained in the system and was detected in the vent pipe of no. 20 Reclamation Street without any further injection of the tracer gas. This also suggests that these drainage pipes were poorly ventilated while there were no residents in the buildings. At the end of the second day, we also injected tracer gas into the drainage system of the building at no. 20 Reclamation Street and monitored the concentration in vent pipes of the buildings at no. 22 and no. 24 Reclamation Street, but none was detected (electronic supplementary material, figure S5 ), suggesting possible different flow direction, i.e. it was possible for no. 26 stack tracer to migrate to no. 20, but not from no. 20 to no. 22 and no. 24. The time constraint did not permit us to carry out further investigations. The most striking feature of this Tong Lau outbreak is the high attack rate. The estimated attack rate is 25.4% (34/134 residents). This has been one of the highest attack rates observed in Hong Kong and ranked among the highest attack rates in reported outbreaks internationally. For example, an attack rate of 67%, 36% and 22% was reported in homeless shelters [15] [16] [17] , and 24% in 10 fitness centres [18] . The very high attack rate in this Tong Lau outbreak lies in the crowdedness, poor indoor ventilation without windows for many subdivided units, and unauthorized modification of the building drainage system. Our field study demonstrated satisfactory hygiene conditions in the subdivided units that we had access to, but the shared open corridor and one stairwell were blocked with poor hygiene. The 21 confirmed symptomatic cases had symptom onset dates from 27 December 2020 to 14 January 2021, over a period of 19 days. The epidemic curve was not suggestive of a singlesource infection. We used a validated back-calculation method [19, 20] to estimate the exposure dates of these symptomatic cases, and three exposure periods could be identified. Comparing figure 10 and figure 2 , one may infer that the first five cases in no. 26 were exposed to the virus around 25-30 December 2020. The second exposure occurred on 3 January, which possibly led to infections from nos. 20, 22 and no. 26 and the third exposure peak occurred around 7 January. The back calculation is only indicative, as the number of cases is small and the estimated incubation period was from data in the first phase of the pandemic in the mainland [20] . From the sequencing result of the 23 residents, at least 17 are identical and the other differs by 1-2 SNP, and this is suggestive of a clonal spread originating from a single common source ( figure 4) . These findings suggest that the 20-26 Reclamation Street outbreak might be a propagated outbreak where a close contact transmission route is possible. While the current study does not pinpoint the exact transmission routes, it is able to identify several risk factors for transmission. First, tracer gas data prove the possibility of spread via the drainage system, especially in no. 26 Reclamation Street. Similar tracer gas spread tests were conducted in seven other outbreaks with a vertical pattern of the infected flats in Hong Kong and Guangzhou. In these outbreaks, the transport of the stack aerosols by the drainage pipes was shown to be likely [14] . Stack aerosols were generated within the drainage pipes and stacks when wastewater was discharged after toilet flushing or washbasin discharge. The driving force for the airflow in the drainage pipes was probably dominated by the chimney effect [14] . Our demonstration that adding warm water augmented tracer gas leakage clearly demonstrated the enhanced chimney effect. Our monitored data revealed that the stack aerosols can spread vertically in 26 Reclamation Street, but can also spread between Tong Lau houses as shown by the roof vent data ( figure 11 ). The non-approved drainage pipe modification to accommodate for an individual toilet-cum-bathroom in each subdivided unit might have contributed to the vertical and horizontal spread via the drainage systems as shown by the tracer gas studies. Second, the ventilation within the subdivided units was poor. Each subdivided unit is small. In no. 26 Reclamation Street, the house most affected with cases, the small 62.5 m 2 flat on each floor was subdivided into 4 to 7 units. The ventilation conditions in these flats were expected to be very poor and were confirmed in the one unit measurement and onsite visits during our investigation. The shared narrow corridor in each flat was also not ventilated. The poorly ventilated environment could have explained why two or three infected cases were reported in some of these very small subdivided units (table 1) . Our monitored data clearly showed that it is possible for the tracer gas to spread between subdivided royalsocietypublishing.org/journal/rsfs Interface Focus 12: 20210063 units. Unfortunately, we were unable to identify the exact air flow route in such complex multi-zone settings and thus it was not possible to determine the effect of wind direction and thermal buoyancy. The respiratory aerosol spread is also likely due to inadequate ventilation. Airborne transmissions between units were also observed in the 2003 Amoy Garden outbreak [21] and airborne transmission of SARS-CoV-2 has gained increasing acceptability [22] . People living in close proximity such as in the same household are known to have a high attack rate. Households were found to be one of the dominant infection venues in many parts of the world [23] and crowded environments are known to facilitate the transmission of infections (e.g. [24, 25] ). For example, among migrant workers in Singapore, almost 93% of Singapore's COVID-19 cases were related to migrant workers in dormitories where one room may house up to 20 workers. Within the first 48 days, cases within the dormitories had surged to more than 40 000, compared with fewer than 2600 infections elsewhere in the compact city-state [24] . Fortunately, the Reclamation Street infection cluster did not lead to a similar explosive spread in Hong Kong, probably due to the swift assertive public health control measures implemented by the Government, including compulsory testing and quarantine in affected areas. In addition to overcrowding, our site visit revealed the physical and spatial difficulties in having an adequate building wastewater drainage system in such small subdivided units. Ventilation is also limited as the toilets or kitchens are windowless. Most subdivided units in 22 and 24 Reclamation Street are also anticipated to be windowless. Hence, in addition to the crowded living environment, the poor design of the drainage system and ventilation in the studied subdivided units very likely contributed to the described massive outbreak of COVID-19 here. There are many similar Tong Lau houses with subdivided units in Hong Kong [4, 5] although the exact number is unknown. Our observations and findings revealed an urgent need to improve housing conditions in these Tong Lau houses. Proper regulation of the subdivided unit design, if it cannot be avoided, is essential. In a developed society, these old traditional housings can be a complex issue. On the one hand, it may be possible to improve the building drainage and ventilation to minimize the infection risk and other indoor environmental issues through innovative and careful designs. The extremely small residential unit offers an opportunity for such a careful effort, e.g. using advanced analysis and design tools to maximize the system performance [26, 27] as a commonly used design approach for building drainage systems may not be applicable to the unique difficulties in such extremely subdivided units, i.e. very long horizontal pipes, the need of integration into the existing vertical stack and vent pipes. The ventilation duct design also needs to be properly sized and designed as some subdivided units do not have a window. The demand for such fine design may conflict with the economic considerations of the owners as the subdivision is for rental, hence the increased cost for such delicate designs and constructions can be a major hurdle. On the other hand, there might be an option to forbid the creation of such extremely small residential units. In Hong Kong, Tong Lau residents had a significantly lower level of satisfaction towards their living environments when comparing with those in public and private housings [7] . The causality of suboptimal living environments in poor housing conditions remained to be investigated. Our study demonstrated the issue with wastewater drainage system and ventilation in subdivided units in four Tong Lau houses, with public health implications. This study has several limitations. First, only one outbreak within four Tong Lau houses was studied. However, the observed poor drainage system design and poor ventilation conditions are likely to be similar in other subdivided units, as it is the physical space constraints in these subdivided units that limit the drainage system layout and ventilation access. Second, the experiments were carried out over a very short period. After the residents were relocated to quarantine camps, the four Tong Lau houses were subjected to thorough disinfection before the research team could perform site visits. Due to time constraints, several important experiments such as roof vent monitoring and tracer gas decay tests for ventilation rate were not repeated. Moreover, we only received permission for entry to a few subdivided units only, thus were unable to assess other potentially important elements such as if the water seals were dried out in the units of the infected cases. The complete design of the subdivided unit remained unknown, as they are likely to be owned by different landlords and built by different contractors. However, our findings in the five infected units were very illustrative of the issues associated with the complex indoor environment. Lastly, we were unable to undertake a questionnaire study to look at the social interaction among the residents, including the confirmed COVID-19 cases. However, due to the limited space within the small subdivided units, it would be highly unlikely that there will be many social gatherings in the same unit. The spread of COVID-19 infection among residential buildings in this outbreak seems to be the result of a multipleroute transmission of infectious aerosols (i.e. the transport by the poor drainage system with enhanced exposure due to poor ventilation conditions, close contact due to social gathering). The adding of warm water into the drainage system, and the operation of the exhaust fan in the bathroom enhanced the suction rate of tracer gas in each unit. The horizontal cluster of confirmed COVID-19 patients among the subdivided units in one flat may be attributed to inter-unit royalsocietypublishing.org/journal/rsfs Interface Focus 12: 20210063 transmission due to design flaws of the exhaust pipes. Our study offers a glimpse into the complexities of the indoor environmental issues faced by residents who live in extremely small residential units, where space constraints not only apply to people, but also in building drainage systems and ventilation. The findings in the four Tong Lau houses, which probably apply to many Tong Lau settings, may provide a reference for building designers and building regulations in Hong Kong. Ethics. The study protocol was approved by the Research Ethics Commit- Institutional Review Board of the University of Hong Kong/Hospital Authority Hong Kong West Cluster The data are provided in the electronic supplementary material The structural and social determinants of the racial/ethnic disparities in the US COVID-19 pandemic. What's our role? Association of poor housing conditions with COVID-19 incidence and mortality across US counties Indoor air quality in substandard housing in Hong Kong Responding to COVID-19 in Hong Kong Rent determinants of subdivided units in Hong Kong Living environment and quality of life in Hong Kong Evaluation of an indoor environmental quality model for very small residential units Observing and quantifying airflows in the infection control of aerosol-and airborne-transmitted diseases: an overview of approaches Experimental and numerical investigation of airflow and contaminant transport in an airliner cabin mockup Posterior oropharyngeal saliva for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) 2021 Emergence of a severe acute respiratory syndrome coronavirus 2 virus variant with novel genomic architecture in Hong Kong Evidence of airborne transmission of the severe acute respiratory syndrome virus Probable evidence of fecal aerosol transmission of SARS-CoV-2 in a high-rise building Coronavirus disease 2019 (COVID-19) outbreak in a San Francisco homeless shelter 2020 Prevalence of SARS-CoV-2 infection in residents of a large homeless shelter in Boston COVID-19 outbreak among three affiliated homeless service sites Epidemiological characteristics of COVID-19 outbreak at fitness centers in Cheonan Predicting super spreading events during the 2003 severe acute respiratory syndrome epidemics in Hong Kong and Singapore Lack of cross-transmission of SARS-CoV-2 between passenger's cabins on the Diamond Princess cruise ship Multi-zone modeling of probable SARS virus transmission by airflow between flats in Block E 2021 COVID-19 has redefined airborne transmission 2020 Indoor transmission of SARS-CoV-2 Cities-try to predict superspreading hotspots for COVID-19 Migrant workers and COVID-19 The simulation of air pressure propagation in building drainage and vent systems Transient airflow in building drainage systems High attack rate in a Tong Lau house outbreak of COVID-19 with subdivided units in Hong Kong Authors' contributions. Q.W.: formal analysis, investigation, visualization, writing-original draft and writing-review and editing; D.C.L.: data curation, formal analysis, writing-review and editing; P.C.