key: cord-0797389-exf1mh36 authors: Ahn, Su Jeong; Baek, Yun Hee; Lloren, Khristine Kaith S.; Choi, Won-Suk; Jeong, Ju Hwan; Antigua, Khristine Joy C.; Kwon, Hyeok-il; Park, Su-Jin; Kim, Eun-Ha; Kim, Young-il; Si, Young-Jae; Hong, Seung Bok; Shin, Kyeong Seob; Chun, Sungkun; Choi, Young Ki; Song, Min-Suk title: Rapid and simple colorimetric detection of multiple influenza viruses infecting humans using a reverse transcriptional loop-mediated isothermal amplification (RT-LAMP) diagnostic platform date: 2019-08-01 journal: BMC Infect Dis DOI: 10.1186/s12879-019-4277-8 sha: dd12c39ca963dca8336d7f30c8842d892ec8236c doc_id: 797389 cord_uid: exf1mh36 BACKGROUND: In addition to seasonal influenza viruses recently circulating in humans, avian influenza viruses (AIVs) of H5N1, H5N6 and H7N9 subtypes have also emerged and demonstrated human infection abilities with high mortality rates. Although influenza viral infections are usually diagnosed using viral isolation and serological/molecular analyses, the cost, accessibility, and availability of these methods may limit their utility in various settings. The objective of this study was to develop and optimized a multiplex detection system for most influenza viruses currently infecting humans. METHODS: We developed and optimized a multiplex detection system for most influenza viruses currently infecting humans including two type B (both Victoria lineages and Yamagata lineages), H1N1, H3N2, H5N1, H5N6, and H7N9 using Reverse Transcriptional Loop-mediated Isothermal Amplification (RT-LAMP) technology coupled with a one-pot colorimetric visualization system to facilitate direct determination of results without additional steps. We also evaluated this multiplex RT-LAMP for clinical use using a total of 135 clinical and spiked samples (91 influenza viruses and 44 other human infectious viruses). RESULTS: We achieved rapid detection of seasonal influenza viruses (H1N1, H3N2, and Type B) and avian influenza viruses (H5N1, H5N6, H5N8 and H7N9) within an hour. The assay could detect influenza viruses with high sensitivity (i.e., from 100 to 0.1 viral genome copies), comparable to conventional RT-PCR-based approaches which would typically take several hours and require expensive equipment. This assay was capable of specifically detecting each influenza virus (Type B, H1N1, H3N2, H5N1, H5N6, H5N8 and H7N9) without cross-reactivity with other subtypes of AIVs or other human infectious viruses. Furthermore, 91 clinical and spiked samples confirmed by qRT-PCR were also detected by this multiplex RT-LAMP with 98.9% agreement. It was more sensitive than one-step RT-PCR approach (92.3%). CONCLUSIONS: Results of this study suggest that our multiplex RT-LAMP assay may provide a rapid, sensitive, cost-effective, and reliable diagnostic method for identifying recent influenza viruses infecting humans, especially in locations without access to large platforms or sophisticated equipment. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12879-019-4277-8) contains supplementary material, which is available to authorized users. The World Health Organization constantly monitors global influenza activity. It has noted global circulation of H1N1, H3N2, and two lineages of type B (Victoriaand Yamagata-) viruses that cause 670,000 annual deaths worldwide [1] . In the past few years, human infections with several subtypes of avian influenza virus (AIV) (e.g., H5 and H7) occurred sporadically [2] . Highly pathogenic avian influenza (HPAI) H5N1 and H5N6 viruses have infected 878 humans with 53% mortality since 1997 [3] . Since the first case of human infection with low pathogenic avian influenza (LPAI) H7N9 virus reported in China in 2013, the number of humans infected with this virus has dramatically increased to more than 1,567 as of April 2019 [4] . Recognizing this public concern, it is important to distinguish seasonal influenza and avian influenza viruses such as H5 and H7N9 that occur simultaneously in humans, especially in China. Vaccination and treatment with antiviral drugs (e.g., neuraminidase inhibitors (NAIs)) are primary interventions to prevent viral infections and their spread. However, vaccine production usually takes 6-12 months to prepare for newly emerging viruses. NAIs also should be taken within the first 48 h following an infection [5] . Thus, rapid and accurate diagnosis of viral infections is important for mitigating the spread of virus within a community, facilitating immediate treatment with NAIs, and controlling carriers of these pathogens. Methods to detect and identify influenza viruses have improved over the past decades, ranging from traditional virus culture [6] to introduction of serological and molecular diagnostic technology (e.g., real-time RT-PCR [7] and PCR [8] ) and more recently, rapid influenza detection tests (RIDT) [9] [10] [11] . With various influenza-specific diagnostic tools, selecting the most appropriate approach is based on a number of factors, including sensitivity, specificity, throughput, cost, and availability [12] . Virus isolation and serology method has traditionally been used to detect influenza virus. However, it may take several days to obtain results [13] . RIDT is a rapid method of performing point-of-care testing (POCT) in the field. Most RIDT diagnostic kits can detect influenza nucleoprotein antigen [14] . However, RIDT has two potential limitations: i) relatively large numbers of influenza viruses must be present for accurate detection in the collected sample, and ii) inability to distinguish between influenza subtypes. Overall, sensitivity and accuracy of RIDT are lower than those of qRT-PCR-based methods that not only can amplify small amounts of target viral RNA, but also can allow for determination of influenza A virus subtype using specifically designed primers [12] . Despite qRT-PCR-based approaches have these advantages, they typically take at least a few hours up to 2 days to obtain results [15] . In addition, qRT-PCR needs trained personnel and sophisticated facilities for sample processing. These disadvantages limit its function in ensuring rapid prescription and administration of antiviral agents to patients. Recently, many Clinical Laboratory Improvement Amendments (CLIA)-waived molecular tests have been approved for point-of-care use (https://www.cdc.gov/flu/professionals/diagnosis/molecular-assays.htm). Although the detection time (similar to RIDT) and sensitivity (better than RIDT) of CLIA-waived molecular tests have been improved, they are mostly limited to seasonal flu detection. They are incapable of discriminating seasonal influenza of avian subtypes that can cause human infection [16] . Loop-mediated isothermal amplification (LAMP) assays can amplify specific nucleic acids at a consistent temperature. They have been used for rapid detection of specific genes [17] [18] [19] [20] . In particular, LAMP method combined with reverse transcription (called RT-LAMP) is a method for simultaneously synthesizing cDNA from template RNA and amplifying DNA [21] . Thus, RT-LAMP is useful for detecting RNA viruses. In addition, polymerase enzyme produces protons and subsequently leads to decreased pH in the presence of extensive DNA polymerase activity during LAMP reaction, thus facilitating real-time and simple detection of amplicons as observed by a change from pink to yellow color in the reaction solution [22] . The specificity and sensitivity of RT-LAMP are potentially comparable to those of existing PCR-based diagnostics with much shorter reaction time. Recently, influenza diagnostics tools leveraging RT-LAMP technology have been reported [23] [24] [25] [26] [27] [28] [29] [30] . However, most of these tools can only diagnose a single or a small number of human influenza viruses. Their ability to diagnose newly emerging viruses is limited. None of these methods can simultaneously differentiate infection of seasonal influenza from multiple avian influenza virus infection including recently emerging H5Nx and H7N9, although this is critical when infection by those viruses to humans simultaneously occurs. Thus, the objective of this study was to develop a multiplex RT-LAMP diagnostic method capable of simultaneously detecting human influenza viruses (two lineages of type B, H1N1 and H3N2) currently circulating in humans and avian influenza viruses (H5N1, H5N6 and H7N9) in rapidly emerging human infections. This assay also involves a one-pot colorimetric visualization approach that allows for direct observation by the naked eye. Overall, this diagnostic assay may be useful as a rapid and highly sensitive POCT that requires no laboratory equipment for field-based applications. To determine virus infectious titers, 50% tissue culture infectious dose (TCID 50 ) assay was performed in MDCK cells. Each virus was individually prepared by serial 10-fold dilutions in infection medium (minimal essential medium). The prepared virus diluent was used to infect MDCK cells in 96-well plates and incubated at 37°C for 1 h in a CO 2 incubator. Supernatants were then replaced with infection medium (MEM) with 1 μg/L L-(tosylamido-2-phenyl) ethyl chloromethyl ketone (TPCK)-treated trypsin. After 2~3 days of incubation, virus titers were determined using the hemagglutination (HA) assay with 0.5% turkey or chicken red blood cells (RBCs). Then 200 μl of virus stock was used to extract viral RNA using RNeasy Mini Kit (Qiagen, Hilden, Germany) according to the manufacturer's protocol. After extraction, RNA was stored at − 80°C until use. More than 200 HA gene sequences of H1N1, H3N2, H5N1, H5N6, H5N8, and H7N9 with NA gene sequences of influenza B viruses (both Victoria and Yamagata lineages) were downloaded from NCBI Influenza Virus Resource Database (https://www.ncbi.nlm. nih.gov/genomes/FLU) and analyzed with CLC Genomics Workbench to identify highly conserved regions within similar subtypes distinct from other subtypes (Fig. 1) . RT-LAMP primer sets for each influenza subtype were designed using LAMP primer design software (Primer Explorer V4). Primer sets included two external primers (forward outer primer F3 and backward outer primer B3), two internal primers (forward inner primer FIP and backward inner primer BIP), and two loop primers (backward loop primer LB and forward loop primer LF) to augment the number of loops in the LAMP reaction, thus enhancing its reaction speed. Type B influenza-specific primers were designed to be specific for NA gene based on consensus sequence identified in 200 sequences of its two lineages (Victoria and Yamagata). Alternatively, influenza subtype-specific primers were designed to be specific to HA gene based on consensus sequences identified among 200 random sequences for each of H1N1, H3N2, H5N1, H5N6, H5N8, and H7N9 subtypes. All primers were synthesized by Cosmogenetech (Republic of Korea). Detailed information for all five primer sets used in this study is presented in Table 1 . To optimize the sensitivity and specificity of RT-LAMP detection, various primer concentrations (2.5 to 20 μM for external primer F3 and B3, 20 to 80 μM for internal primer FIP and BIP, and 5 to 20 μM for loop primer LF and LB) were used. For RT-LAMP reactions, a master mix solution was prepared containing 5 μl of Warm-Start® Colorimetric LAMP 2X Master Mix (NEB, UK), 1 μl of each F3 and B3 primer, 1 μl of each FIP and BIP primer, and 1 μl of each LF and LB primer for each reaction. Optimized final concentration of each primer is presented in Table 1 . Then 2 μl of RNA template extracted from virus was added to the master mix. The RT-LAMP reaction was performed at 65°C for 60 min. It was then heated at 80°C for 10 min for enzyme inactivation in a heat block. Positive RT-LAMP reactions resulted in a color change of phenol red pH indicator from pink to yellow due to decreased pH in the presence of extensive DNA polymerase activity. Thus, results could be directly observed by naked eyes. RT-LAMP results were also confirmed by 2% agarose gel electrophoresis. Comparing sensitivities of multiplex RT-LAMP, conventional one-step RT-PCR, and quantitative (q)RT-PCR To compare sensitivity of our multiplex RT-LAMP assay to those of conventional one-step RT-PCR and qRT-PCR approaches, extracted RNA samples were serially diluted 10-fold to 10 − 6 . Then 2 μl of serially diluted RNA was mixed with the optimized master mix and subjected to RT-LAMP as described above. One-step RT-PCR was performed using 10 pmol of outer primers (F3 and B3) and equal amount of serially diluted RNA template as used for RT-LAMP with TOPscript™ One-step RT-PCR Kit (Enzynomics, Republic of Korea) under the following conditions: reverse transcription at 55°C for 30 min, initial denaturation at 95°C for 5 min, 35 cycles of denaturation at 95°C for 30s, annealing at 60°C for 30s, elongation at 72°C for 30s, and a final elongation step at 72°C for 5 min. qRT-PCR was performed using TOPreal™ One-step RTqPCR Kit (SYBR Green, low Rox) (Enzynomics, Republic of Korea) with 10 pmol of outer primers (F3 and B3) and equal RNA template as used for RT-LAMP. PCR conditions were the same as those performed for the one-step RT-PCR described above using a real-time machine, CFX96 TouchTM Real-Time PCR Detection System (Bio-Rad, Hercules, CA, USA). Results of RT-LAMP and one-step RT-PCR were visually confirmed using 2% agarose gel electrophoresis. To determine the specificity of the optimized multiplex RT-LAMP assay for targeting tested influenza viruses H12N5) were assessed using the multiplex RT-LAMP assay described in this study. In addition, one-step RT-PCR or qRT-PCR was performed to confirm the presence of viral genomic RNA using specific primer sets (Additional file 1: Table S1 ). One-step RT-PCR conditions were the same as described above. Results of one-step RT-PCR were confirmed using 2% agarose gel electrophoresis. A total of 73 influenza-positive (confirmed using a qRT-PCR method) clinical nasopharyngeal aspirate samples collected from patients who demonstrated flu-like symptoms at Chungbuk National University Hospital, Republic of Korea were used for clinical evaluation of the RT-LAMP diagnostic assay developed in this study. In addition, 18 spiked samples in which 10 4 TCID 50 /ml of viruses (i.e., H1N1, H5N6, H5N8, and H7N9) were diluted into flu-negative human nasopharyngeal aspirate samples Following standardization and optimization, final concentrations of each primer set were fixed to be 5 μM for F3 and B3, 40 μM for FIP and BIP, and 10 μM for LF and LB for detecting type B and H3 subtypes, 5 μM for F3 and B3, 80 μM for FIP and BIP, and 10 μM for LF and LB for detecting the H1 subtype, and 5 μM for F3 and B3, 80 μM for FIP and BIP, 5 μM for LF and LB for detecting H5 and H7 subtypes (Table 1) . Targeted genes of specific subtypes were successfully amplified using these designed RT-LAMP primers and observed by color changes within RT-LAMP reaction tubes (Fig. 2a) . A change in color from pink to light yellow indicated a positive reaction while negative reactions retained a pink color (Fig. 2) . The specificity of these RT-LAMP primers was additionally verified using mixed virus samples in various combinations. Targeted genes in mixed virus samples were also specifically amplified by RT-LAMP primers (Fig. 2b ). In addition, agarose gel electrophoresis of RT-LAMP products showed a typical ladder-like banding pattern (Additional file 1: Figure S1 ). These results indicate that multiplex RT-LAMP primers described here can efficiently and specifically detect corresponding subtypes. They can also detect multiple human influenza virus genes as a universal element in this RT-LAMP assay. To determine the detection limit of the multiplex RT-LAMP assay for human influenza viruses and avian influenza viruses infecting humans, we performed amplification of endpoint-diluted viral RNA extracted from each virus after propagation in 11-day-old chicken embryonic eggs for 48-72 h at 33°C for type B viruses and 37°C for type A viruses. RNA of each virus was serially diluted (10-fold up to 10 − 6 ) in distilled water (DW). Infectious viral particles were determined using TCID 50 / ml. Infectious viral genome copies per microliter of extracted RNA were estimated and presented in Table 2 . Table S1 for additional details of one-step RT-PCR primer sequences As shown in Table 2 and Additional file 1: Figure S2 , the multiplex RT-LAMP assay revealed a detection limit range of 0.1~100 viral genome copies (p < 0.05) for all human influenza viruses and avian influenza viruses infecting humans in our panel [i.e., type B (Victoria-and Yamagata-lineages), seasonal H1N1, H3N2, highly pathogenic avian influenza H5N1, H5N6, and H5N8 isolated from human and avian species, and human H7N9 viruses]. On the other hand, the conventional one-step RT-PCR and real-time RT-PCR assays demonstrated detection limits ranging from 0.1~1,000 infectious viral genome copies for the same viral RNA samples (Table 2 and Additional file 1: Figure S2 ). Total reaction and observation time of conventional PCR-based detection methods took 2~3 h while colorimetric visualization of multiplex RT-LAMP assay results took only 1 h. Overall, these results demonstrate that the multiplex RT-LAMP assay developed in this study targeting HA or NA gene of influenza viruses exhibits similar or higher sensitivity with reduced detection time compared to conventional PCR-based assays. We also examined the specificity of the multiplex RT-LAMP assay using other subtypes of influenza (H2, H4, H6, H9, H10, H11, and H12) and other human infectious viruses obtained from a total of 44 clinical/spiked samples positive for HEV, AdV, PIV, MPV, HboV, HRV, 229E, NL63, OC43, RSVA, RSVB, and MERS-CoV that might potentially be in co-circulation with target viruses and cause similar symptoms. Based on colorimetric assessments, the RT-LAMP reaction using each primer set for H1, H3, H5, and H7, and type B viruses demonstrated no cross-reactivity with other influenza subtypes or human infectious viruses tested ( Fig. 3 and Table 3 ). Conventional RT-PCR and qRT-PCR assays using specific primers (Additional file 1: Table S1 ) for other influenza subtypes and human infectious viruses were also performed to verify the presence of corresponding viral RNA. Target gene amplification was observed (Fig. 3 and Table 3 ). These results indicate that the RT-LAMP assay can specifically detect influenza viruses tested in the current study. Evaluation of the multiplex RT-LAMP assay using clinical and spiked samples (Table 4 ). In addition, 100% of H5N6, H5N8, and H7N9 samples were detectable using this developed RT-LAMP assay. However, 83~100% of influenza viruses in clinical and spiked samples were detected using conventional RT-PCR, showing greater that 6% reduction in sensitivity compared to the RT-LAMP assay (Table 4 ). These results suggest that the multiplex RT-LAMP diagnostic assay described in this study is as sensitive as qRT-PCR. However, it provides results more rapidly with greater simplicity. Influenza virus, an acute respiratory infectious agent, can rapidly propagate in the upper respiratory tract. It is capable of airborne transmission to other individuals [33] . Prescribing anti-influenza drugs following rapid and accurate diagnosis of an infection is thus critical to mitigate viral spread in the early stage of an outbreak. Many primary care providers use RIDT to diagnose influenza infections because it is simple to use with relatively rapid results. However, the accuracy of this approach is lower than that of qRT-PCR. A highly accurate gene-based diagnostic assay would serve as a valuable local on-site tool if it is easy to use with rapid results. Although many CLIAwaived molecular tests satisfy these criteria due to recent advancement, most of these developed tests are limited to detect seasonal influenza without appropriate subtype discrimination. In this study, we developed a multiplex RT-LAMP method to distinctively diagnose human influenza (e.g., seasonal influenza type B, H1N1, H3N2) and avian influenza viruses infecting humans (e.g., H5N1, H5N6, and H7N9). Hence, this developed method would be essential in some countries where these viruses are cocirculating in humans. Moreover, the RT-LAMP method described here can be used to intuitively detect these viruses using a one-pot colorimetric visualization approach, making it a more feasible POCT. Our multiplex RT-LAMP detection system was designed to be a more feasible RIDT with accuracy as high as RT-PCR methods for detecting most recent human influenza viruses and avian influenza viruses infecting humans. Although a variety of reliable and affordable RT-LAMP methods have been developed to detect human or avian influenza viruses, each can only detect an individual subtype [23-29, 34, 35] or limited subtypes of human influenza viruses and/or avian influenza viruses infecting humans [18, 30, 36, 37] . In a pandemic, it is critical to rapidly differentiate patients infected by seasonal flu from those infected by an emerging strain. Thus, reliable and affordable multiplex detection tools should be capable of identifying broadspectrum influenza viruses infecting humans. Moreover, RT-LAMP method for most recent emerging HPAI H5N6 and H5N8 viruses which have high potential to infect humans has rarely been developed or evaluated for its detection efficacy. In addition to broad-spectrum detection of human influenza viruses using our multiplex RT-LAMP assay, we optimized commercially available colorimetric RT-LAMP enzyme. Previous studies have also shown that the colorimetric visualization system using dyes (e.g., SYBR) is detectable by naked eyes [38] . However, these colorimetric methods require additional steps (e.g., adding dye to test for color changes after reaction or the use of a UV device for visualization [39] ) that can decrease their utility in resource-limited primary care settings. RT-LAMP assay is one of promising diagnostics tools that can be utilized to empower disease detection in developing countries as it does not require sophisticated, expensive equipment or trained personnel. The complex design of each specific primer sets made to amplify target sequence with high degree of sensitivity and specificity is one of major recognized constraints of this assay. Recognizing its advantages when detecting RNA genome of viral pathogens, RT-LAMP assay still requires improvement, particularly for the RNA extraction step, to be an efficient and suitable field-based diagnostic tool. Current approaches for RNA extraction of nasopharyngeal swabs or aspirate specimens collected from influenza-suspected patients usually require laboratory processing equipment (e.g., use of centrifuge system and others laboratory devices), technical support, and electricity. Thus, the use of chaotropic salt extraction which does not require centrifugation [40] would improve the feasibility of the developed multiplex RT-LAMP method as it utilizes a syringe with RNA-binding filter method [41] . Furthermore, it has been reported that the RT-LAMP reaction could be performed without RNA extraction step for some RNA viruses [42] . Although our multiplex RT-LAMP assay has not been optimized to directly detect influenza viral RNA without RNA sample preparation, it would significantly increase its feasibility as a diagnostic tool for POCT. Although RT-LAMP assays designed to detect Victoria lineage Type-B viruses has 10 times less sensitivity compared to one-step RT-PCR and qRT-PCR approaches, RT-LAMP reactions for other subtypes exhibited similar or higher sensitivity without crossreaction to various human infectious viruses and other subtypes of avian influenza viruses. Furthermore, our multiplex RT-LAMP assay was more sensitive than a conventional RT-PCR approach using clinical or spiked samples. Although the RT-LAMP detection method for H7N9 was optimized and evaluated, single spiked sample for clinical verification would be a limitation of the method. The specificity of multiplex RT-LAMP assay demonstrated in this current study might have limitations for use as a primary detection method based on local epidemiological setting. However, this assay's rapid detection has a valuable contribution by providing diagnostics specifically in areas with prevalent avian influenza viruses infecting humans. Our multiplex RT-LAMP method not only can minimize the use of expensive lab instruments and devices, but also can detect broad-spectrum human influenza viruses and avian influenza viruses infecting humans as accurately and more rapidly than conventional RT-PCR-based detection methods suitable for use in on-site testing. This method will improve and aid in the diagnosis of influenza infections and potentially increase the speed of clinicians to provide appropriate treatment. Additional file 1 : Figure S1 . Specificity of RT-LAMP. The specificity of the RT-LAMP assay was tested using (A) individual and (B) mixed influenza virus samples listed below. RT-LAMP amplicon was confirmed using 2% agarose gel electrophoresis. The positive sample (yellow color) has a typical ladder-like pattern of RT-LAMP reaction. Figure S2 . Sensitivity of the RT-LAMP assay compared with conventional methods. To estimate the sensitivity of the RT-LAMP assay, RNA samples from each influenza viruses were 10-fold serially diluted and used as templates for the RT-LAMP assay (A), conventional RT-PCR (B), and realtime qRT-PCR (C). RT-LAMP results are visualized colorimetrically and by gel-electrophoresis. Results of conventional RT-PCR (B) and real-time qRT-PCR (C) are visualized using gel electrophoresis and cycle threshold (Ct) values, respectively. Please see Table 2 for the full name of virus used. N.C., negative control. Table S1 . Primers for detection of influenza viruses of other subtypes and human 3 respiratory disease viruses. (PDF 565 kb) Influenza (Seasonal) Fact sheet H7N9 situation update Neuraminidase inhibitors for treatment of human and avian strain influenza: a comparative modeling study Diagnostic virology: from animals to automation Serological response in RT-PCR confirmed H1N1-2009 influenza a by hemagglutination inhibition and virus neutralization assays: an observational study Detection and identification of human influenza viruses by the polymerase chain reaction Rapid antigen tests for diagnosis of pandemic (swine) influenza a/H1N1 Diagnosis of 2009 pandemic influenza A (pH1N1) and seasonal influenza using rapid influenza antigen tests Rapid-test sensitivity for novel swineorigin influenza a (H1N1) virus in humans Tools to detect influenza virus Detection of respiratory viruses by molecular methods Improvement of a rapid diagnosis kit to detect either influenza a or B virus infections Real-time PCR in virology Point-of-care testing for infectious diseases: past, present, and future Sensitive and rapid detection of herpes simplex virus and varicella-zoster virus DNA by loop-mediated isothermal amplification Rapid detection and typing of influenza a and B by loop-mediated isothermal amplification: comparison with immunochromatography and virus isolation Development and evaluation of real-time loop-mediated isothermal amplification for hepatitis B virus DNA quantification: a new tool for HBV management Development of a loop-mediated isothermal amplification method for rapid detection of caprine arthritisencephalitis virus proviral DNA Loop-mediated isothermal amplification of DNA Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes Development of H5-RT-LAMP (loop-mediated isothermal amplification) system for rapid diagnosis of H5 avian influenza virus infection Reversetranscription, loop-mediated isothermal amplification assay for the sensitive and rapid detection of H10 subtype avian influenza viruses Visual detection of pandemic influenza a H1N1 virus 2009 by reverse-transcription loop-mediated isothermal amplification with hydroxynaphthol blue dye Development of a reverse transcription loop-mediated isothermal amplification assay for the rapid diagnosis of avian influenza a (H7N9) virus infection Evaluation of reverse transcription loop-mediated isothermal amplification assays for rapid diagnosis of pandemic influenza a/ H1N1 2009 virus Development and evaluation of a reverse transcription loop-mediated isothermal amplification assay for H3N8 equine influenza virus Development of a reverse transcription loop-mediated isothermal amplification assay for H7N7 equine influenza virus Rapid detection of novel influenza a virus and seasonal influenza a (H1N1, H3N2) viruses by reverse transcription-loop-mediated isothermal amplification (RT-LAMP) Highly pathogenic avian influenza virus (H5N1) in domestic poultry and relationship with migratory birds Rapid acquisition of polymorphic virulence markers during adaptation of highly pathogenic avian influenza H5N8 virus in the mouse Transmission of influenza a in human beings Loop-mediated isothermal amplification for influenza a (H5N1) virus. Emerg Infect Dis Visual detection of human infection with influenza a (H7N9) virus by subtype-specific reverse transcription loop-mediated isothermal amplification with hydroxynaphthol blue dye Multiplex loopmediated isothermal amplification (M-LAMP) assay for the detection of influenza a/H1, a/H3 and influenza B can provide a specimen-to-result diagnosis in 40 min with single genome copy sensitivity Multiplex reverse-transcription loop-mediated isothermal amplification coupled with Cascade invasive reaction and nanoparticle hybridization for subtyping of influenza a virus Rapid detection of Tembusu virus by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP) Rapid diagnosis of H5N1 avian influenza virus infection by newly developed influenza H5 hemagglutinin gene-specific loop-mediated isothermal amplification method Sample preparation: a challenge in the development of point-of-care nucleic acid-based assays for resourcelimited settings Portable system for microbial sample preparation and oligonucleotide microarray analysis A smartphonebased diagnostic platform for rapid detection of Zika, chikungunya, and dengue viruses Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations Availability of data and materials All data generated or analyzed during this study are included in this published article and its supplementary information files. This study was performed in compliance with the ethical guidelines under the Institutional Review Board (IRB) of the Chungbuk National University Hospital. In brief, the study has an approved written consent for the RNAs extracted from nasopharyngeal samples collected from patients at Chungbuk National University Hospital (Republic of Korea) due to acute respiratory disease syndrome were used to evaluate the sensitivity and specificity of the multiplex RT-LAMP assay in accordance with procedures approved by the Institutional Review Board of Chungbuk National University Hospital with approved code of IRB no. CBNUH 2018-01-001-002. All highly pathogenic viruses were handled in an enhanced biosafety level 3 (BL-3+) facility according to the standard operation protocol approved by Korea Centers for Disease Control and Prevention (KCDC). All experiments were performed with written consent and in accordance with the approved guidelines. Not applicable. The author Young Ki Choi is a member of the BMC Infectious Diseases editorial board. All other authors have no competing interests to declare.