key: cord-0797049-7kzbrygn authors: Pembaur, Anton; Sallard, Erwan; Weil, Patrick Philipp; Ortelt, Jennifer; Ahmad-Nejad, Parviz; Postberg, Jan title: Simplified Point-of-Care Full SARS-CoV-2 Genome Sequencing Using Nanopore Technology date: 2021-12-16 journal: Microorganisms DOI: 10.3390/microorganisms9122598 sha: f3d9088c7002c3f4af1e6ea558af8ac1fab09d85 doc_id: 797049 cord_uid: 7kzbrygn The scale of the ongoing SARS-CoV-2 pandemic warrants the urgent establishment of a global decentralized surveillance system to recognize local outbreaks and the emergence of novel variants of concern. Among available deep-sequencing technologies, nanopore-sequencing could be an important cornerstone, as it is mobile, scalable, and cost-effective. Therefore, streamlined nanopore-sequencing protocols need to be developed and optimized for SARS-CoV-2 variants identification. We adapted and simplified existing workflows using the ‘midnight’ 1200 bp amplicon split primer sets for PCR, which produce tiled overlapping amplicons covering almost the entire SARS-CoV-2 genome. Subsequently, we applied Oxford Nanopore Rapid Barcoding and the portable MinION Mk1C sequencer combined with the interARTIC bioinformatics pipeline. We tested a simplified and less time-consuming workflow using SARS-CoV-2-positive specimens from clinical routine and identified the CT value as a useful pre-analytical parameter, which may help to decrease sequencing failures rates. Complete pipeline duration was approx. 7 h for one specimen and approx. 11 h for 12 multiplexed barcoded specimens. The adapted protocol contains fewer processing steps and can be completely conducted within one working day. Diagnostic CT values deduced from qPCR standardization experiments can act as principal criteria for specimen selection. As a guideline, SARS-CoV-2 genome copy numbers lower than 4 × 10(6) were associated with a coverage threshold below 20-fold and incompletely assembled SARS-CoV-2 genomes. Thus, based on the described thermocycler/chemistry combination, we recommend CT values of ~26 or lower to achieve full and high-quality SARS-CoV-2 (+)RNA genome coverage. To face the ongoing SARS-CoV-2 (Severe Acute Respiratory Syndrome Coronavirus 2) pandemic, a global decentralized warning system is being established to recognize local outbreaks and the emergence of novel variants of concern (VOC). A particular focus is given to the identification of VOCs with accelerated transmission rates, increased infectivity or immune escape mutations as these variants would warrant adaptations in containment and vaccination strategies [1] [2] [3] [4] . Moreover, the search for the zoonotic origin of SARS-CoV-2 from comparative analyses of genomic data is an ongoing issue with relevance for the early recognition of future outbreak scenarios [5, 6] . 2 Among the available deep-sequencing technologies, nanopore-sequencing could be an important cornerstone, since it is mobile, scalable and acquisition investments are comparatively low. Further, nanopore sequencing devices do not require large-scale information technology (IT) infrastructure. They were already involved in genome surveillance, e.g., during the 2015 Ebola outbreak in Liberia, Guinea and Sierra Leone [7] , even though nanopore technology was not as developed as today. However, at least for smaller hospital laboratories with lower throughput, it is still desirable to develop further streamlined protocols. Nanopore sequencing allows the sequencing of either DNA or RNA [8] , and does not require PCR amplification. Furthermore, the technique has the potential of producing very long, continuous reads, which theoretically allows to sequence in only one read the 29.903 nt long (+)RNA genome of SARS-CoV-2 [9] , or its deriving cDNA after reverse transcription ( Figure 1 ). Microorganisms 2021, 9, x FOR PEER REVIEW 2 of 10 SARS-CoV-2 from comparative analyses of genomic data is an ongoing issue with relevance for the early recognition of future outbreak scenarios [5, 6] . Among the available deep-sequencing technologies, nanopore-sequencing could be an important cornerstone, since it is mobile, scalable and acquisition investments are comparatively low. Further, nanopore sequencing devices do not require large-scale information technology (IT) infrastructure. They were already involved in genome surveillance, e.g., during the 2015 Ebola outbreak in Liberia, Guinea and Sierra Leone [7] , even though nanopore technology was not as developed as today. However, at least for smaller hospital laboratories with lower throughput, it is still desirable to develop further streamlined protocols. Nanopore sequencing allows the sequencing of either DNA or RNA [8] , and does not require PCR amplification. Furthermore, the technique has the potential of producing very long, continuous reads, which theoretically allows to sequence in only one read the 29.903 nt long (+)RNA genome of SARS-CoV-2 [9] , or its deriving cDNA after reverse transcription ( Figure 1 ). (2) (3) (4) (5) (6) compatible with diagnostic qPCR pipelines (1) . The pyrosequencing option in the path (6) requires biotin-tagged primers for qPCR [10] . With the aims of facilitating implementation in routine diagnostics with lower specimens throughput and of simplifying the workflow, we tested modifications of existing ARTIC protocols for SARS-CoV-2 full length (+)RNA genome sequencing [11] [12] [13] . Furthermore, we tested the simplified and less time-consuming workflow on confirmed SARS-CoV-2-positive specimens from clinical routine and identified parameters, most importantly CT values corresponding to standardized viral genome copies, which may help to decrease the rate of sequencing failures. Specimens used in this study included mainly nasopharyngeal swabs (Xebios Diagnostics) routinely sampled from non-hospitalized individuals by public health authorities. Before study inclusion as anonymized specimens, routine COVID-19 diagnostic testing was conducted. (1) . The pyrosequencing option in the path (6) requires biotin-tagged primers for qPCR [10] . With the aims of facilitating implementation in routine diagnostics with lower specimens throughput and of simplifying the workflow, we tested modifications of existing ARTIC protocols for SARS-CoV-2 full length (+)RNA genome sequencing [11] [12] [13] . Furthermore, we tested the simplified and less time-consuming workflow on confirmed SARS-CoV-2-positive specimens from clinical routine and identified parameters, most importantly CT values corresponding to standardized viral genome copies, which may help to decrease the rate of sequencing failures. Specimens used in this study included mainly nasopharyngeal swabs (Xebios Diagnostics) routinely sampled from non-hospitalized individuals by public health authorities. Before study inclusion as anonymized specimens, routine COVID-19 diagnostic testing was conducted. Total RNA was extracted from 250 µL liquid specimen using either 750 µL QIAzol lysis reagent (Qiagen, Hilden, Germany) upon manufacturer's recommendations or purification The 'midnight' split primer set from the ARTIC protocol was used for SARS-CoV-2 cDNA amplification in 2 multiplex PCR reactions [11] . To avoid overlaps during multiplex PCR, each single-tube PCR reaction generates consecutively tiled, non-overlapping 1200 bp amplicons. Mixed together after PCR, both resulting complementary amplicon mixtures cover almost the entire SARS-CoV-2 genome. Combined reverse transcription and amplification of multiple 1200 bp amplicons (RT-PCR) were performed in single tube 20 µL reactions using the Luna One-Step RT-qPCR Kit (NEB; E3005). For RT-PCR, 8 µL of purified template RNA were used for each reaction. 1 µL of 100 µM primer pool was used in each reaction. Reverse transcription was performed at 55 • C for 30 min, followed by incubation at 95 • C for one minute. Then 34 cycles (pool 1) or 30 cycles (pool 2) of denaturation at 95 • C for 20 s and annealing and extension in one step at 60 • C for 210 s were performed. A final extension was performed at 65 • C. During the implementation phase, amplicon sizes and DNA concentrations were routinely checked by agarose gels or by microvolume electrophoresis using an Agilent Bioanalyzer instrument and a microfluidic chip (Agilent DNA 12,000 kit, Agilent). Thereafter, amplicons from primer pools 1 and 2 were quantified using the QuantiFluor dsDNA System (Promega, Madison, WI, USA) with the Promega Quantus fluorometer and then mixed at equal concentrations. Library preparation was done using the Rapid Barcoding Sequencing Kit (SQK-RBK004; Oxford Nanopore Technologies, Oxford, UK) upon manufacturer's recommendations. Sequencing was performed on a MinION Mk1C (Oxford Nanopore Technologies) with the options 'basecalling' and 'demultiplexing' being enabled, both performed by the included 'guppy' algorithm. As output format, FAST5 and FASTQ files were chosen. Sequencing time was set for 72 h as default. Sequencing was stopped after reaching at least 10 megabases for each barcode. Consensus sequences were built from the barcode-sorted, quality-filtered FAST5 and FASTQ files containing sequencing reads, using the interARTIC pipeline. Except otherwise stated, the 'Nanopolish' algorithm was routinely used. Installation and usage of interARTIC pipeline were done following the developers' instructions: InterARTIC Documentation. Available online: https://psy-fer.github.io/ interARTIC/installation/ (accessed on 14 December 2021). For faster analysis, all available threads were activated in the advanced settings. The interARTIC pipeline performs read filtering, alignments and returns a consensus FASTA file as well as coverage charts for visualization ( Figure 2B-H) . Consensus FASTA files were uploaded to the Nextstrain webapp (Nextclade. Available online: https://clades.nextstrain.org [accessed on 14 December 2021]) to perform phylogenetic analyses [14] . , whereby viral copy numbers were 1.28 × 10 6 (B); 5.12 × 10 8 (C); 2.56 × 10 8 (D); 4 × 10 6 (E); 2 × 10 6 (F); 1 × 10 6 (G); 5 × 10 5 (H). In (A) increasing barcode numbers (X-axis) correspond to decreasing viral titers. Consensus FASTA files were uploaded to the Nextstrain webapp (Nextclade. Available online: https://clades.nextstrain.org [accessed on 14 December 2021]) to perform phylogenetic analyses [14] . We defined milestones to simplify the protocol and decrease hands-on sample time and working step numbers. 1. We tested whether specimens can be directly taken from residual diagnostic specimens extracted from 96-deepwell-plates using magnetic beads (Seegene NIMBUS/Tanbead). For comparison, we applied RNA purification protocols using silica columns (QiaAmp Viral Mini Kit, Qiagen) or guanidinium isothiocyanate Figure 2 . Surveillance using nanopore sequencing (A), and effects of specimens dilution on the SARS-CoV-2 genome coverage (B), whereby viral copy numbers were 1.28 × 10 6 (B); 5.12 × 10 8 (C); 2.56 × 10 8 (D); 4 × 10 6 (E); 2 × 10 6 (F); 1 × 10 6 (G); 5 × 10 5 (H). In (A) increasing barcode numbers (X-axis) correspond to decreasing viral titers. We defined milestones to simplify the protocol and decrease hands-on sample time and working step numbers. 1. We tested whether specimens can be directly taken from residual diagnostic specimens extracted from 96-deepwell-plates using magnetic beads (Seegene NIMBUS/Tanbead). For comparison, we applied RNA purification protocols using silica columns (QiaAmp Viral Mini Kit, Qiagen) or guanidinium isothiocyanate (GITC) for RNA extraction (QIAzol lysis reagent, Qiagen). 2. We tested whether reverse transcription can be successfully primed by SARS-CoV-2-specific primers, which are subsequently used for multiplex 1200 bp amplicon amplification. Purified RNA from the different extraction protocols of milestone 1 was used for cDNA synthesis and successive multiplex PCR with the 2 'midnight' split 1200 bp amplicon primer pools in single tube reactions. 3. We aimed at improving the efficiency of the nanopore sequencing workflow by using the onboard Guppy basecalling capability of the Oxford Nanopore MinION Mk1C device. Moreover, implementation of the interARTIC interface should help to avoid command line-based bioinformatics analyses as much as possible to provide a user-friendly and efficient analysis pipeline. Sequencing was performed from serially diluted specimens of purified RNA from patients' samples, which exhibited low cycle threshold (CT) value (CT = 16-18) after routine diagnostics RT-qPCR (N gene, RdRP gene; Seegene). Using the quantitative reference sample Ch07470 for calibration we determined that a CT = 25 (respectively 16 and 18) corresponded to a SARS-CoV-2 copy number of 1.0 × 10 6 (respectively 5.12 × 10 8 and 1.28 × 10 8 ). Routinely used dilution factors were 2 0 -2 −10 to cover several CT value magnitudes and to simulate different amounts of viral loads. In terms of RNA yield and 1200 bp amplicon PCR performance, the magnetic beads-based RNA purification protocol outperformed slightly the GITC method as well as the column-based protocol, but we did not observe differences in read and coverage quality between these different isolation methods ( Figure S1 ). Since direct sampling from 96-deepwell plates allowed us to directly exploit residual specimens, which remained after routine RT-qPCR diagnostics, we decided to focus on magnetic beads-based RNA purification during further protocol development. Moreover, it shortened and simplified the workflow. After semiquantitative or quantitative RT-PCR using multiplex primer pools 1 and 2 in separate single-tube reactions for combined reverse transcription of the SARS-CoV-2 (+)RNA and amplification of 1200 bp amplicons, band intensities exhibited a strong dependence on viral loads. Moreover, after 32 PCR cycles band intensities using primer pool 1 were weaker when compared with primer pool 2 ( Figure S2 ). We determined that 34 PCR cycles for primer pool 1 and 30 cycles for primer pool 2 were a good compromise. Therefore, reverse transcription can be successfully primed by the 'midnight' primers. Using the Rapid Barcoding Kit (SQK-RBK004, Oxford Nanopore) enabled us to barcode the PCR products without purification steps and sequence them immediately. As a standard, we used 12 barcoded libraries for multiplex sequencing on R9 flow cells. In contrast to the Oxford Nanopore MinION Mk1B, the MinION Mk1C device features onboard guppy basecalling. In combination with the Rapid Barcoding Kit, we exploited this opportunity for real-time surveillance of basecalling and demultiplexing for each of the 12 multiplexed samples per run. This enabled us to recognize the exact time point at which a reading depth of approx. 10 Mbp per barcode was achieved. The time to reach this threshold depended heavily on the viral load (simulated by serially diluted samples). Decreased viral loads led to a considerable decrease of passed reads (Figure 2A) . A manual stop of sequencing followed by flow cell washing (Flow Cell Wash Kit, EXP-WSH004, Oxford Nanopore) allowed us to reuse a single flow cell for a series of 3 sequencing runs, each using 12 multiplexed barcoded libraries. This specific scenario resulted in costs of approx. 40 USD per sample. Theoretically, the possible number of reuses depends largely on the duration of the sequencing, which itself depends mainly on the number of used barcodes. Further, if a MinION Mk1B is considered for this purpose, a similar surveillance functionality could be achieved using RAMPART (artic-network/rampart. Available online: https://github.com/artic-network/rampart [accessed on 14 December 2021]) on a dedicated LINUX environment. RAMPART runs simultaneously with MinKNOW and exhibits demuxing and mapping results in real-time. For mapping and full-length SARS-CoV-2 genome assembly, we used the FASTQ files resulting from Guppy basecalling to generate FASTA formatted consensus sequence files. We used the ARTIC pipeline through a graphical user interface (Psy-Fer/interARTIC. Available online: https://github.com/Psy-Fer/interARTIC [accessed on 14 December 2021]). Once installed, this is an easy to use and relatively fast pipeline with only five minutes of hands-on time, which enables the use of the 'Nanopolish' or 'Medaka' algorithms for simultaneous analyses of multiplexed barcoded samples. As an example, Figure 2B shows the complete and deep coverage of the complete SARS-CoV-2 genome after the combination of pools 1 (light blue) and 2 (pink). This demonstrates that all contained 1200 bp amplicon were specifically and efficiently amplified during the combined RT-PCR reaction ( Figure 2B) . To compare the interARTIC and Geneious Prime pipelines, we used exactly the same FASTQ file from the same sample shown in Figure 2B (geneious-How to assemblecoronavirus genomes. Available online: https://go.geneious.com/video/howto-assemble-coronavirus-genomes [accessed on 14 December 2021]). Phylogenetic analyses with Nextstrain using the FASTA consensus files obtained from the interARTIC or the Geneious Prime pipelines resulted in considerably different phylogenetic distances in clade 20I, showing that the bioinformatics pipeline influences the result ( Figure S3 ). Notably, despite the calculated different phylogenetic distances using Geneious, the sample was still assigned to clade 20I. We speculate that the reason for this distance bias might be due to the Illumina-optimized assembly pipeline of Geneious. The interARTIC pipeline proved superior in terms of coverage and sequencing depth. Notably, within the interARTIC pipeline both options, the 'Nanopolish' and 'Medaka' algorithms performed equally well with respect to consensus sequence quality, but 'Medaka' was considerably faster. We observed that the consensus sequences returned by the 'Nanopolish' and 'Medaka' algorithms contain numerous unsolved regions (for which only 'N's are indicated). Interestingly, the regions unsolved by one algorithm were generally solved by the other, so we assumed that the two consensus sequences could be combined to produce a 'superconsensus' with improved variant prediction value. We developed a Python code that merges the 'Nanopolish' and 'Medaka' consensus sequences and generates the corresponding variant calling file. As expected, the 'super-consensus' contained fewer unsolved regions when compared with the 'Nanopolish' and 'Medaka' consensus sequences alone ( Figure 3B ). In addition, it retained the high-quality mutations, which were identified by both algorithms, while removing most false positives probably caused by sequencing and alignment errors ( Figure 3A) . Consequently, our consensus-merging code improves the quality of variant calling and highlights the complementarity of 'Nanopolish' and 'Medaka' for nanopore-sequencing of SARS-CoV-2 and others. Nevertheless, this quality increase comes at the cost of information loss such as the number of reads per variant or other metadata which were initially generated by 'Nanopolish' and 'Medaka' and are not transferred to the 'super-consensus'. Serial input RNA dilutions or, respectively, viral load influenced the depth of sequencing ( Figure 2C-H) . For the output of high-quality consensus sequences in the FASTA file format, a coverage threshold of 20 was used as default. We generally observed that this could be reached when a SARS-CoV-2 titer of 4 × 10 6 was given. Viral copy numbers lower than 4 × 10 6 were associated with incompletely assembled SARS-CoV-2 genomes. Thus, we provide here a convincing line of evidence that the copy number-normalized CT values of diagnostic RT-qPCR can be used as the criterion of sequencing success. Microorganisms 2021, 9, x FOR PEER REVIEW 7 of 10 Serial input RNA dilutions or, respectively, viral load influenced the depth of sequencing ( Figure 2C-H) . For the output of high-quality consensus sequences in the FASTA file format, a coverage threshold of 20 was used as default. We generally observed that this could be reached when a SARS-CoV-2 titer of 4 × 10 6 was given. Viral copy numbers lower than 4 × 10 6 were associated with incompletely assembled SARS-CoV-2 genomes. Thus, we provide here a convincing line of evidence that the copy number-normalized CT values of diagnostic RT-qPCR can be used as the criterion of sequencing success. Single or batch high-quality consensus FASTA formatted sequences were used for phylogenetic tree visualization and variant calling using the Nextstrain webapp (Nextclade. Available online: https://clades.nextstrain.org [accessed on 14 December 2021]) [14] . In our hands, the obtained sequences could faithfully be assigned to specific clades in the reference tree ( Figure 4) . Again, an influence of viral load was observed. However, despite incomplete coverage in those cases enough informative sequence data could be obtained for phylogenetic analyses from several low copy number samples. As a result of serial sample dilutions, we observed deviating phylogenetic distances within the clade, wherein specimens classification occurred ( Figure 4A) , which eventually could lead to incorrect clade association. The use of specimens from diagnostic routine with viral copy numbers higher than approx. 4 × 10 6 apparently led to their faithful association with different clades, which were clades 20I and 19A in the shown example ( Figure 4B ). The 'Nanopolish' and 'Medaka' consensus as well as the merged super-consensus could be reliably associated with the corresponding clade (20I in the shown example). The Single or batch high-quality consensus FASTA formatted sequences were used for phylogenetic tree visualization and variant calling using the Nextstrain webapp (Nextclade. Available online: https://clades.nextstrain.org [accessed on 14 December 2021]) [14] . In our hands, the obtained sequences could faithfully be assigned to specific clades in the reference tree ( Figure 4) . Again, an influence of viral load was observed. However, despite incomplete coverage in those cases enough informative sequence data could be obtained for phylogenetic analyses from several low copy number samples. As a result of serial sample dilutions, we observed deviating phylogenetic distances within the clade, wherein specimens classification occurred ( Figure 4A ), which eventually could lead to incorrect clade association. The use of specimens from diagnostic routine with viral copy numbers higher than approx. 4 × 10 6 apparently led to their faithful association with different clades, which were clades 20I and 19A in the shown example ( Figure 4B ). The 'Nanopolish' and 'Medaka' consensus as well as the merged super-consensus could be reliably associated with the corresponding clade (20I in the shown example). The 'Medaka' consensus mapped at a greater distance than the 'Nanopolish' consensus, probably because the 'Medaka' algorithm does not correct frameshifts, while the super-consensus had an intermediary distance between the two other consensuses ( Figure 3C ). 'Medaka' consensus mapped at a greater distance than the 'Nanopolish' consensus, probably because the 'Medaka' algorithm does not correct frameshifts, while the super-consensus had an intermediary distance between the two other consensuses ( Figure 3C ). Comparison on the evolutionary distance calculation, when data from the same specimen was processed by 2 different bioinformatics pipelines. Phylogenetic tree visualization was done using the Nextstrain open-source platform for pathogen genome data analyses [14] . We used serial dilutions of identical specimens (A), or a selection of samples from different individuals from clinical routine (B) for phylogenetic analyses. Below the trees, a magnification of clade 20I is shown, wherein most specimens are grouped (A,B). Taken together, the main achievements of an optimized workflow are 1. Purified RNA from SARS-CoV-2-positive patients can be directly taken from residual diagnostic specimens in 96-deepwell-plates; 2. cDNA synthesis and successive multiplex PCR with 2 split primer pools can be performed in single tube reactions. Since cDNA synthesis is primed by SARS-CoV-2-specific primers for 1200 bp amplicon amplification, there is no need for use of unspecific hexanucleotide priming, which are unspecific for SARS-CoV-2 (+)RNA during cDNA synthesis and could thus influence subsequent PCR reactions; 3. Onboard Guppy basecalling with the Oxford Nanopore MinION Mk1C device and implementation of the interARTIC led to a further reduction of working steps and hands-on time ( Figure 5 ). Implementation in smaller hospital laboratories with lower specimens' throughput can be easily done at moderate costs. We provide a detailed protocol for all steps here, which includes the Python code ( Supplementary Information 1) and corresponding command line: nanopore nCoV-2019 sequencing protocol. Available online: dx.doi.org/10.17504/protocols.io.bx72prqe (accessed on 12 December 2021). Taken together, the main achievements of an optimized workflow are 1. Purified RNA from SARS-CoV-2-positive patients can be directly taken from residual diagnostic specimens in 96-deepwell-plates; 2. cDNA synthesis and successive multiplex PCR with 2 split primer pools can be performed in single tube reactions. Since cDNA synthesis is primed by SARS-CoV-2-specific primers for 1200 bp amplicon amplification, there is no need for use of unspecific hexanucleotide priming, which are unspecific for SARS-CoV-2 (+)RNA during cDNA synthesis and could thus influence subsequent PCR reactions; 3. Onboard Guppy basecalling with the Oxford Nanopore MinION Mk1C device and implementation of the interARTIC led to a further reduction of working steps and handson time ( Figure 5 ). Implementation in smaller hospital laboratories with lower specimens' throughput can be easily done at moderate costs. We provide a detailed protocol for all steps here, which includes the Python code ( Supplementary Information 1) and corresponding command line: nanopore nCoV-2019 sequencing protocol. Available online: dx.doi.org/10.17504/protocols.io.bx72prqe (accessed on 12 December 2021). Comparison of a rapid SARS-CoV-2 whole (+)RNA genome nanopore sequencing pipeline [11] with the novel simplified workflow, whose main achievements are: 1. Purified RNA from SARS-CoV-2-positive patients can be directly taken from residual diagnostic specimens in 96-deepwell-plates; 2. cDNA synthesis and successive multiplex PCR with 2 primer pools can be performed in single tube reactions. Since cDNA synthesis is primed by SARS-CoV-2-specific primers for 1200 bp amplicon amplification, there is no need for use of unspecific hexanucleotide priming; 3. Onboard Guppy basecalling with the Oxford Nanopore MinION Mk1C device and implementation of the interARTIC led to a further reduction of working steps and hands-on time. The adapted protocol contains fewer processing steps than previous workflows (Figure 5) . Diagnostic CT values are the principal criteria for specimen selection as variants could be accurately identified for initial viral loads of 4.10 6 or above. After diagnostic qRT-PCR, multiplex library preparation, quality controls, nanopore sequencing and the bioinformatics pipeline can be completely conducted within one working day. Supplementary Materials: The following are available online at www.mdpi.com/xxx/s1, Supplementary Materials Collection, containing Figure S1 : Comparison of different isolation methods with respect to PCR performance, Figure S2 : The influence of viral loads on amplification, Figure S3 : Comparison of phylogenetic distances, Supplementary Information 1: Merging consensus sequences. Author Contributions: A.P. prepared libraries for nanopore-seq and conducted the sequencing. P.A.-N. and J.O. collected specimens and conducted diagnostic SARS-CoV-2 qPCR. A.P., and P.P.W. performed nucleic acid quality controls. A.P., E.S., and J.P. contributed to the bioinformatics analyses. E.S. developed the Python code. P.A.-N. and J.P. designed the study. A.P., E.S., P.P.W. and J.P. wrote the paper. All authors have read and agreed to the published version of the manuscript. The study was financed by its own institutional means. The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Ethics Committee of Witten/Herdecke University (No. 160/2020). For cases of routinely sampled material from non-hospitalized individuals by public health authorities, no informed written consent was obtained. In other cases, we obtained written informed consent from hospitalized COVID-19 patients for the use of nasopharyngeal specimens, which were sampled for routine COVID-19 diagnostic testing. However, specimens sampled from COVID-19 patients after prolonged hospitalization rarely exhibited high viral loads and turned out to be less useful for method establishment. For the collection and use of specimens from hospitalized and non-hospitalized individuals after clinical routine COVID-19 diagnostic testing at Helios University Hospital Wuppertal (North Rhine-Westphalia, Western Germany) we obtained approval Figure 5 . Comparison of a rapid SARS-CoV-2 whole (+)RNA genome nanopore sequencing pipeline [11] with the novel simplified workflow, whose main achievements are: 1. Purified RNA from SARS-CoV-2-positive patients can be directly taken from residual diagnostic specimens in 96-deepwell-plates; 2. cDNA synthesis and successive multiplex PCR with 2 primer pools can be performed in single tube reactions. Since cDNA synthesis is primed by SARS-CoV-2-specific primers for 1200 bp amplicon amplification, there is no need for use of unspecific hexanucleotide priming; 3. Onboard Guppy basecalling with the Oxford Nanopore MinION Mk1C device and implementation of the interARTIC led to a further reduction of working steps and hands-on time. The adapted protocol contains fewer processing steps than previous workflows ( Figure 5 ). Diagnostic CT values are the principal criteria for specimen selection as variants could be accurately identified for initial viral loads of 4 × 10 6 or above. After diagnostic qRT-PCR, multiplex library preparation, quality controls, nanopore sequencing and the bioinformatics pipeline can be completely conducted within one working day. Supplementary Materials: The following are available online at https://www.mdpi.com/article/ 10.3390/microorganisms9122598/s1, Supplementary Materials Collection, containing Figure S1 : Comparison of different isolation methods with respect to PCR performance, Figure S2 : The influence of viral loads on amplification, Figure S3 : Comparison of phylogenetic distances, Supplementary Information 1: Merging consensus sequences. Author Contributions: A.P. prepared libraries for nanopore-seq and conducted the sequencing. P.A.-N. and J.O. collected specimens and conducted diagnostic SARS-CoV-2 qPCR. A.P. and P.P.W. performed nucleic acid quality controls. A.P., E.S. and J.P. contributed to the bioinformatics analyses. E.S. developed the Python code. P.A.-N. and J.P. designed the study. A.P., E.S., P.P.W. and J.P. wrote the paper. All authors have read and agreed to the published version of the manuscript. The study was financed by its own institutional means. The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Ethics Committee of Witten/Herdecke University (No. 160/2020). For cases of routinely sampled material from non-hospitalized individuals by public health authorities, no informed written consent was obtained. In other cases, we obtained written informed consent from hospitalized COVID-19 patients for the use of nasopharyngeal specimens, which were sampled for routine COVID-19 diagnostic testing. However, specimens sampled from COVID-19 patients after prolonged hospitalization rarely exhibited high viral loads and turned out to be less useful for method establishment. For the collection and use of specimens from hospitalized and non-hospitalized individuals after clinical routine COVID-19 diagnostic testing at Helios University Hospital Wuppertal (North Rhine-Westphalia, Western Germany) we obtained approval from the Witten/Herdecke University Ethics Committee (No. 160/2020). The positive ethics vote included the use of routinely sampled and SARS-CoV-2-confirmed specimens, which underwent COVID-19 RT-qPCR diagnostics procedures even for cases, where informed written consent could not be asked for. When possible, we obtained informed written consent from hospitalized patients or legal guardians. All work has been conducted according to the principles expressed in the Declaration of Helsinki. Informed Consent Statement: For cases of routinely sampled material from non-hospitalized individuals by public health authorities, patient consent was waived. Those samples were provided in anonymized form after routine diagnostic testing. Informed consent was obtained from all hospitalized COVID-19 patients for the use of nasopharyngeal specimens, which were sampled for routine COVID-19 diagnostic testing. Data Availability Statement: FASTQ files and assembled FASTA formatted consensus sequences are available (Genome Sequence Archive (GSA). Available online: https://bigd.big.ac.cn/gsa/browse/ CRA005542 [accessed on 14 December 2021]). Concerns about SARS-CoV-2 evolution should not hold back efforts to expand vaccination Will SARS-CoV-2 variants of concern affect the promise of vaccines? SARS-CoV-2 variants, spike mutations and immune escape The Spike of Concern-The Novel Variants of SARS-CoV-2. Viruses The proximal origin of SARS-CoV-2 Coronavirus biology and replication: Implications for SARS-CoV-2 Real-time, portable genome sequencing for Ebola surveillance Highly parallel direct RNA sequencing on an array of nanopores Direct RNA sequencing and early evolution of SARS-CoV-2 Combined RT-qPCR and pyrosequencing of a Spike glycoprotein polybasic cleavage motif can uncover pediatric SARS-CoV-2 infections associated with heterogeneous presentation Rapid and inexpensive whole-genome sequencing of SARS-CoV-2 using 1200 bp tiled amplicons and Oxford Nanopore Rapid Barcoding Rapid genomic characterization of SARS-CoV-2 viruses from clinical specimens using nanopore sequencing Improvements to the ARTIC multiplex PCR method for SARS-CoV-2 genome sequencing using nanopore Nextstrain: Real-time tracking of pathogen evolution There are no conflicting interests for none of the authors, which need declaration. (+)RNA (sense polarity [single-stranded] ribonucleic acid), RdRP (RNA-dependent RNA polymerase), RT-qPCR (reverse transcription-quantitative polymerase chain reaction, SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2).