key: cord-0796757-wph2nsgg authors: Leach, Katherine C.; Ellsworth, Misti G.; Ostrosky, Luis Z.; Bell, Cynthia S.; Masters, Kathy; Calhoun, John; Ferguson, Lance; Distefano, Susie; Chang, Michael L. title: Evaluation of a telethermographic system for temperature screening at a large tertiary-care referral hospital during the coronavirus disease 2019 (COVID-19) pandemic date: 2020-10-12 journal: Infection control and hospital epidemiology DOI: 10.1017/ice.2020.1254 sha: 714ee629f960b359895cffcbfba17071ecc4f0db doc_id: 796757 cord_uid: wph2nsgg nan Since the outset of the coronavirus disease 2019 (COVID-19) pandemic, the United States Centers for Disease Control and Prevention has recommended screening and triage for signs and symptoms of infection for everyone entering a healthcare facility. 1 In compliance, everyone entered our hospital (a tertiary-care referral center in a large metropolitan area) in several single-file lines, and underwent individual symptom screening and temperature check by temporal artery thermometer that required skin contact and cleaning of the probe cone between uses. Despite optimizations, temperature screening resulted in long lines during employee shift changes, which compromised social distancing and exposed screeners to hundreds of individuals in close proximity. During this period, the US Food and Drug Administration issued guidance for initial temperature assessment during a triage process using telethermographic systems (thermal cameras) able to determine surface skin temperature from a distance without skin contact. 2 We sought to determine the feasibility of replacing temporal artery thermometers with a telethermographic system and the impact of such a system on our screening process. TemporalScanner thermometers (Exergen Corp, Watertown, MA) and the Athena Elevated Temperature Detection System (Athena Security, Austin, TX). Exergen reports their instruments to be accurate within 0.2°C and 0.1°C, respectively. 3,4 The Athena telethermographic system uses artificial intelligence to detect human faces by measuring the temperature of multiple points on the face relative to a blackbody temperature reference source. 5 According to Athena Security, the system is accurate within 0.3°C. 5 Systems were purchased from Athena Security. Accepting manufacturer specifications, detecting 0.2°C difference between devices (assuming standard deviation of ±0.3°C) required 26 measurements from each device. One subject was measured 104 times with 4 different TAT-2000s (26 measurements per device) and 104 times with 4 different TAT-5000s (26 measurements per device) by a single operator, and 13 times with the Athena system at a single location within 90 minutes to minimize subject and environmental temperature variation. We repeated measurements with the same subject and thermometer operator at a second location with 3 additional TAT-5000s, 1 TAT-5000 used previously (104 measurements, 26 per device) and a second thermal camera (13 measurements). We simulated fever using airactivated hand warmers (HotHands, Kobayashi Americas, Dalton, GA) held to the forehead. Descriptive statistical analyses were performed with Stata version 15 SE software (StataCorp, College Station, TX). Summaries were reported as means with 95% confidence intervals and differences were tested by 1-way ANOVA. A 2sided P < .05 was considered statistically significant. During the first session, the TAT- HotHands warmers reached up to 46.1°C (115°F) 15-30 minutes after activation and were held at the forehead. A "symptomatic" individual in single-file line 6 feet (2 m) between "normal" individuals passing the camera at a rate of 1 individual per second, was detected in 8 of 8 attempts. Additionally, when the forehead was warmed and the warmer then removed, the Athena system was able to detect temperatures of >99°F or 37.2°C (Fig. 1) in 5 of 5 attempts. Screeners using TAT-5000s took a median of 16.5 seconds from the start of taking the temperature through cleaning the device until the thermometer was ready again. The Athena system has no effective delay from person to person passing in a singlefile line. The COVID-19 pandemic has led to the implementation of temperature screening in a wide variety of facilities. Although temperature screening has been used in public settings during previous infectious diseases outbreaks, 6-8 the usefulness of temperature screening to detect potential infections has been questioned. 6, 7 However, temperature screening may discourage symptomatic individuals from entering public places and may increase comfort for healthy people. 8 Our study using noninvasive devices was not designed to test the accuracy of devices, though temporal scanners are widely considered reliable enough for professional use. 9, 10 In our use, temperatures measured by telethermographic systems were similar to those obtained by temporal scanners, suggesting similar performance. Cost is the biggest barrier to implementation for telethermographic systems. For our investment recovery analysis, we considered turnaround time difference between temporal scanners and a thermal camera for each screened individual at a high-entry location with large groups arriving in a short period, desired throughput rate of 1 person per second, maintaining 6-feet (2-m) social distancing and single-file lines for individual symptom screening. We estimated needing 6 temporal scanner operators for every 1 thermal camera operator. With our organization's direct labor rates and overhead costs, investment recovery was estimated to occur in months, leading to adoption of 4 telethermographic systems at our 2 highest-entry locations. We reduced screening staff from 24 to 4 individuals, and there are now no waiting lines at these locations. In conclusion, our experience demonstrates that a telethermographic system improves screening throughput and reports temperatures similar to those recorded by temporal scanners, with acceptable investment recovery time. Interim infection prevention and control recommendations for patients with suspected or confirmed coronavirus disease 2019 (COVID-19) in healthcare settings COVID-19) public health emergency: guidance for industry and Food and Drug Administration staff. US Food and Drug Administration website TemporalScanner thermometer product data sheet: TAT-2000. Exergen website TemporalScanner thermometer product data sheet: TAT-5000. Exergen website Athena's elevated body temperature system to help catch fevers Evaluation of control measures implemented in the severe acute respiratory syndrome outbreak in Beijing Individuals passed camera in single-file line at rate of 1 individual per second~6 feet (~2 m) apart with warmers held to forehead and then removed Group on Prevention of International and Community Transmission of SARS. Public health interventions and SARS spread US airport entry screening in response to pandemic influenza: modeling and analysis Performance of infrared ear and forehead thermometers: a comparative study in 205 febrile and afebrile children Temperature measurements with a temporal scanner: systematic review and meta-analysis Acknowledgments.Financial support. No financial support was received from Exergen or Athena Security. Telethermographic systems were purchased at negotiated discounted price from Athena Security. All authors have no conflicts of interest or financial relationships to disclose relevant to this manuscript.