key: cord-0792972-ljud1v6m authors: Lei, Yanmin; Qian, Junru; Pan, Dong; Xu, Tingfa title: Research on Small Sample Dynamic Human Ear Recognition Based on Deep Learning date: 2022-02-22 journal: Sensors (Basel) DOI: 10.3390/s22051718 sha: 4225f22e042f4e56b3cc58ba5d56446b90d5d74f doc_id: 792972 cord_uid: ljud1v6m Due to the problem of insufficient dynamic human ear data, the Changchun University dynamic human ear (CCU-DE) database, which is a small sample human ear database, was developed in this study. The database fully considers the various complex situations and posture changes of human ear images, such as translation angle, rotation angle, illumination change, occlusion and interference, etc., making the research of dynamic human ear recognition closer to complex real-life situations, and increasing the applicability of human ear dynamic recognition. In order to test the practicability and effectiveness of the developed CCU-DE small sample database, we designed a dynamic human ear recognition system block diagram based on a deep learning model, which was pre-trained by a migration learning method. Aiming at multi-posture changes under different contrasts, translation and rotation motions, and with or without occlusion, simulation studies were conducted using the CCU-DE small sample database and different deep learning models, such as YOLOv3, YOLOv4, YOLOv5, Faster R-CNN, and SSD. The experimental results showed that the CCU-DE database can be well used for dynamic ear recognition, and it can be tested by using different deep learning models with higher test accuracy. With the acceleration of the informatization process, the fields of information security, social security, national security, and financial transaction security have increasingly higher requirements for the accuracy of personal identity verification. However, the shortcomings of the existing traditional identity authentication methods, in terms of speed, accuracy, and security, are becoming more and more obvious, and it has gradually become more difficult to meet the needs of individuals and society. The rapid development of machine vision, big data and artificial intelligence provides favorable conditions for the development of biometric recognition technology. Therefore, the importance of biometric identification technology in ensuring safety technology is becoming more and more prominent. Existing biometric recognition mainly comprises human face recognition [1] , voice recognition [2] , fingerprint recognition [3] , and iris recognition [4] . Each method has advantages and disadvantages, and has suitable fields of application. Human ears have gradually attracted the attention of relevant scientific researchers due to their characteristics of stability, non-invasiveness, expressionlessness, and significant individual differences [5] . In the current worldwide outbreak of COVID-19, ear recognition research is particularly important because people often wear masks. The difference between human ear recognition and human ear detection is that the former can not only detect the human ear in the picture, but also determine whose ear it is; thus, human identity can be verified through human ear recognition. The block diagram of the dynamic human ear recognition system based on deep learning is shown in Figure 1 . The system is divided into three parts: the dataset construction part, the model training part and the human ear recognition part. The research process can be summarized as: First, ear datasets including training sample sets and test sample sets were constructed. Then, model training was used to train sample datasets to determine the weights of the deep learning models. In order to accelerate the training speed of the model, the transfer learning method was adopted. Finally, the trained human ear recognition model was applied to perform ear recognition by using test sample sets. Finally, the trained human ear recognition model was applied to perform ear recognition by using test sample sets. Human ear recognition Model training Human ear recognition system design Figure 1 . The block diagram of the dynamic human ear recognition system. Due to the problem of insufficient dynamic human ear data, this paper establishes a small sample human ear database (CCU-DE). The data in the database consists of pictures and videos: Eardata1, Eardata2, Eardata3, Eardata4, and Eardata5. The basic idea of establishing this database was to simulate real scenes of real life as much as possible, taking into account that the human ear will perform multi-angle translational and rotational movements in front of the camera, and that human ears will be affected by changes in strong or weak light, such as sunlight, fluorescent lamps and curtains, and that the recognition of human ear is often interfered with by different life scenes such as earphones, glasses, hair, earrings, and so on. The camera device was an ordinary mobile phone camera. The parameters are shown in Table 1 . Value Camera HONOR20 Frame rate 30 Video resolution [16:9] 720p 1280*720 Video format MP4 Image Resolution 3000*4000 Image format JPG Focal length 2.0 The collection site of this database was an open space near the window of the laboratory, with a black wall in the background, which was divided into two types of illumination changes: strong light and low light. The strong light was an environment of sunlight and whole house light in the laboratory; the weak light was an environment of drawn curtains and half the house light in the laboratory. In order to ensure that the lens of the mobile phone and the human ear were kept on a level surface, the mobile phone was placed on a tripod that could be adjusted up and down according to the height of the person being photographed, and the position of the tripod was fixed. The 0° vertical line was defined as a straight line between the wall and the lens, the distance between it and the lens was d = 1.2 m, and it was parallel to the lens. The shooting center was defined as a straight line passing through the center of the lens, Due to the problem of insufficient dynamic human ear data, this paper establishes a small sample human ear database (CCU-DE). The data in the database consists of pictures and videos: Eardata1, Eardata2, Eardata3, Eardata4, and Eardata5. The basic idea of establishing this database was to simulate real scenes of real life as much as possible, taking into account that the human ear will perform multi-angle translational and rotational movements in front of the camera, and that human ears will be affected by changes in strong or weak light, such as sunlight, fluorescent lamps and curtains, and that the recognition of human ear is often interfered with by different life scenes such as earphones, glasses, hair, earrings, and so on. The camera device was an ordinary mobile phone camera. The parameters are shown in Table 1 . The collection site of this database was an open space near the window of the laboratory, with a black wall in the background, which was divided into two types of illumination changes: strong light and low light. The strong light was an environment of sunlight and whole house light in the laboratory; the weak light was an environment of drawn curtains and half the house light in the laboratory. In order to ensure that the lens of the mobile phone and the human ear were kept on a level surface, the mobile phone was placed on a tripod that could be adjusted up and down according to the height of the person being photographed, and the position of the tripod was fixed. The 0 • vertical line was defined as a straight line between the wall and the lens, the distance between it and the lens was d = 1.2 m, and it was parallel to the lens. The shooting center was defined as a straight line passing through the center of the lens, perpendicular to the 0 • vertical line, and the inter-section point with the 0 • vertical line was the shooting center. In the movement area of the human body, we took the center of the shooting as the origin, marked the 0 • and 90 • rectangular coordinate axes with red tape, and marked the human movement route at other angles with green tape. When shooting dynamic human ear videos, in order to make sure the dynamic human ears always appear in the shooting lens, the lens can be adjusted up and down according to the height of the person being photographed in the original position, and the left and right rotation movement can be carried out according to the range of the person being photographed in the lens. We ensured that the photograph centered in the lens, and each video was about 10 s in length. The collection environment is shown in Figure 2 . perpendicular to the 0° vertical line, and the inter-section point with the 0° vertical line was the shooting center. In the movement area of the human body, we took the center of the shooting as the origin, marked the 0° and 90° rectangular coordinate axes with red tape, and marked the human movement route at other angles with green tape. When shooting dynamic human ear videos, in order to make sure the dynamic human ears always appear in the shooting lens, the lens can be adjusted up and down according to the height of the person being photographed in the original position, and the left and right rotation movement can be carried out according to the range of the person being photographed in the lens. We ensured that the photograph centered in the lens, and each video was about 10 s in length. The collection environment is shown in Figure 2 . After shooting, each person was numbered, and his/her name, gender, nationality, native place, date of birth age and other basic information were recorded in the form "CCU-DE Human Ear Database Information Collection Form". In CCU-DE small-sample database, there were 34 participants who were students at Changchun University, named from No. 1 to No. 34. They were aged between 21 and 29 (26% female and 74% male). In the CCU-DE database there were five databases: Eardata1, Eardata2, Eardata3, Eardata4 and Eardata5. The ear database information of each person is shown in Table 2 . Each participant was photographed with 28 static images. No. 1, No. 27 to No. 32 were shot with 24 dynamic videos, while the others were shot with 22 dynamic videos, and the extra 2 videos were rotated 180°. Special attention was paid to the collection of 30 segments of dynamic ear videos of No. 33 (including 6 segments of dynamic ear occlusion videos with 0-degree linear back-and-forth translation). Shooting Situation Eardata1 Static human ear fixed-point shooting Video of human ears moving in translation with the human body when the human body is walking normally at different angles Video of the photographed standing on the shooting center doing a 90° uniform rotation motion Video of the photographed standing on the shooting center doing a 180° uniform rotation motion Eardata5 Dynamic human ear video with the interference information After shooting, each person was numbered, and his/her name, gender, nationality, native place, date of birth age and other basic information were recorded in the form "CCU-DE Human Ear Database Information Collection Form". In CCU-DE small-sample database, there were 34 participants who were students at Changchun University, named from No. 1 to No. 34. They were aged between 21 and 29 (26% female and 74% male). In the CCU-DE database there were five databases: Eardata1, Eardata2, Eardata3, Eardata4 and Eardata5. The ear database information of each person is shown in Table 2 . Each participant was photographed with 28 static images. No. 1, No. 27 to No. 32 were shot with 24 dynamic videos, while the others were shot with 22 dynamic videos, and the extra 2 videos were rotated 180 • . Special attention was paid to the collection of 30 segments of dynamic ear videos of No. 33 (including 6 segments of dynamic ear occlusion videos with 0-degree linear back-and-forth translation). Under a simple black background, the subject stood on the shooting center, the human body was kept upright, the eyes were looking straight ahead, and the fixed-angle shoot was carried out. Figure 3a shows the 3D schematic diagram of the static human ear fixed-point shooting, and Figure 3b shows the plane schematic diagram. Under a simple black background, the subject stood on the shooting center, the human body was kept upright, the eyes were looking straight ahead, and the fixed-angle shoot was carried out. Figure 3a shows the 3D schematic diagram of the static human ear fixed-point shooting, and Figure 3b shows the plane schematic diagram. Table 3 . Table 4 . So, Eardata1 had 952 images. Eardata1 naming rule is personnel number + type (Static State, SS) + Strong Light (HL) or Low Light (LL) + Left Ear (LE) or Right Ear (RE) + rotation angle. For example, "1_SS_HL_RE_45" means that the right ear of the subject of No. 1 was rotated clockwise from position 1 to position 45° under strong light. Table 3 . In the process of rotating clockwise from the direction of position 1 (−45 • ) to the direction of position 2 (45 • ), we collected images from seven angles: the back right ear (−45 • , −30 • , −10 • ), right ear (0 • ) and the front right ear (10 • , 30 • , 45 • ). We took one picture at each angle in bright light and low light. A total of 14 right ear images were collected for each subject. So, there were 34 people and 476 right ear pictures in Eardata1. Eardata1-right is shown in Table 4 . So, Eardata1 had 952 images. Eardata1 naming rule is personnel number + type (Static State, SS) + Strong Light (HL) or Low Light (LL) + Left Ear (LE) or Right Ear (RE) + rotation angle. For example, "1_SS_HL_RE_45" means that the right ear of the subject of No. 1 was rotated clockwise from position 1 to position 45 • under strong light. This database was a video segment for when the human ear moves with the human body when the subject is walking normally along different angles. The translational motion of the human ear simulates the translational motion trajectory of the human ear when the moves through a straight line. The person moves through the four straight lines of α = 135°, α = 150°, α = 165° and α = 180° from the shooting center. At this time, the camera records the translational motion video of the left ear at various angles. When the person moves through the shooting center along the four straight lines of α = 45°, α = 30°, α = 15°, and α = 0°, the camera records the translational motion video of the right ear at various angles. We collected eight videos of each photographed person's two ears. So, there were a total of 16 videos, under both strong and weak illumination, as shown in Table 5 . The number of people collected was 33. Therefore, Eardata2 contained 528 videos in 33 categories. The Eardata2 naming rule was personnel number + type (Translational Motion, TM) + Strong Light (HL) or Low Light (LL) + Left Ear (LE) or Right Ear (RE) + translation angle. For example, "1_TM_HL_RE_45" means that the shooting information of the No. 1 photographed person proceeded dynamic translational movement under strong light conditions, starting from the bottom left along a straight line perpendicular to 0° at a 45° angle, and moved along the straight line through the shooting center to the top right. Eardata3 refers to the video segment in which the subject stands on the shooting center and rotates at a constant speed of 90°. The human ear rotation motion simulates the human ear movement track when the subject turns around in front of the camera in real life, and its plane schematic diagram is shown in Figure 5 . Table 5 . The number of people collected was 33. Therefore, Eardata2 contained 528 videos in 33 categories. The Eardata2 naming rule was personnel number + type (Translational Motion, TM) + Strong Light (HL) or Low Light (LL) + Left Ear (LE) or Right Ear (RE) + translation angle. For example, "1_TM_HL_RE_45" means that the shooting information of the No. 1 photographed person proceeded dynamic translational movement under strong light conditions, starting from the bottom left along a straight line perpendicular to 0 • at a 45 • angle, and moved along the straight line through the shooting center to the top right. Eardata3 refers to the video segment in which the subject stands on the shooting center and rotates at a constant speed of 90 • . The human ear rotation motion simulates the human ear movement track when the subject turns around in front of the camera in real life, and its plane schematic diagram is shown in Figure 5 . The subject stood in the center of the shooting range and rotated at a uniform speed. The rotation angle was from −45 • to 45 • , that is, from P to Q for a video shot for the right ear. The rotation angle was from −135 • to 135 • , that is, from Q' to P' for a video shot for the left ear. Under each kind of light the human ear rotated and two videos were shot. Under the two kinds of light, there were four videos in total, as shown in Table 6 . The rotation angle was from −45° to 45°, that is, from P to Q for a video shot for the right ear. The rotation angle was from −135° to 135°, that is, from Q' to P' for a video shot for the left ear. Under each kind of light the human ear rotated and two videos were shot. Under the two kinds of light, there were four videos in total, as shown in Table 6 . The number of people collected in Eardata3 was 33, with numbers from 1 to 33. So, there were 132 videos. The Eardata3 naming rule was personnel number + type (Rotation Motion, RM) + Strong Light (HL) or Low Light (LL) + Left Ear (LE) or Right Ear (RE). For example, "1_RM_HL_LE" refers to the video information of the subject No. 1 and whose left ear rotated 90° while standing in the shooting center and rotating counterclockwise from −135° to 135° under strong light. Eardata4 was the video segment for the subject standing on the shooting center and rotating at a constant speed of 180°. The video of the right ear movement was shot when the rotation angle rotated clockwise from −90° to 90°, and the video of the left ear movement was shot when the rotation angle rotated counterclockwise from −90° to 90°. The video was only shot under strong light. Two videos of each ear were collected. There were 8 participants with numbers from 27 to 33, and 1. Therefore, Eardata4 contained a total of 16 videos. The information of Eardata4 is shown in Table 7 . Number of videos 1 1 Figure 5 . The rotation motion of the human ear. Eardata4 was the video segment for the subject standing on the shooting center and rotating at a constant speed of 180 • . The video of the right ear movement was shot when the rotation angle rotated clockwise from −90 • to 90 • , and the video of the left ear movement was shot when the rotation angle rotated counterclockwise from −90 • to 90 • . The video was only shot under strong light. Two videos of each ear were collected. There were 8 participants with numbers from 27 to 33, and 1. Therefore, Eardata4 contained a total of 16 videos. The information of Eardata4 is shown in Table 7 . Eardata5 is the dynamic human ear video segment with interference. Interference was used to simulate a situation in which ears were covered by earphones, glasses, hair, scarves, masks, ear studs, or other parts. Eardata5 mainly considers the interference of glasses, earphones, caps, ear studs and hair. In order to reduce the shooting time of the person being photographed, the interference conditions were determined according to the actual situation of the person being photographed. Interference information of Eardata5 is shown in Table 8 . Under strong light, the subjects were required to wear earphones, glasses or caps, and girls could cover part of the ears by disheveling their hair or wearing ear studs. The dynamic human ear occlusion videos of the subjects standing in the center of the shot were collected, showing the rotation of the left and right ears within 90 • range and the straight back and forth movement of 0 • . Among them, the rotation angle from −135 • to 135 • was the motion track for partial occlusion of the left ear, and the rotation angle from −45 • to 45 • was the motion track for partial occlusion of the right ear. A total of 68 videos were collected from 34 people, and 2 videos were collected from each person. In addition, 6 videos of dynamic human ear occlusion with a 0 • straight and back and forth translation motion of No. 33 human ears were captured, including 2 segments of glasses occlusion, 2 segments of "glasses + earphone" occlusion, and 2 segments of "glasses + earphone + cap" occlusion, as shown in Table 9 . Therefore, Eardata5 contained a total of 74 videos in 34 categories. The Eardata5 naming rule is personnel number + interference category (earphone, glasses, hair and cap) + movement type (Rotation Motion, RM or Translational Motion, TM) + Left Ear (LE) or Right Ear (RE). For example, "1_erephone_RM_RE" indicates that this video is the interference video information of the right ear rotating 90 • during the shooting process of the subject No. 1 rotating clockwise from the −45 • direction to the 45 • direction under the interference condition of earphone. From Figure 1 we can see that, in order to test the effectiveness of the deep learning model for dynamic human ear recognition, three datasets were used: (1) COCO [19] , http://cocodataset.org; (2) USTB [14], http://www.ustb.edu.cn/resb; (3) CCU-DE. COCO and USTB datasets which are public and widely used in the field of deep learning and static ear recognition. CCU-DE is a static and dynamic ear database developed in this paper. In order to test the practicability and effectiveness of the proposed CCU-DE small sample database, we set up two groups of experiments. The first group of experiments were based on the YOLOv3 deep learning model. The second group of experiments involved the comparison of the different deep learning models, such as YOLOv3, YOLOv4, YOLOv5, Faster R-CNN and SSD. The experimental parameters were set as follows: 1. The computer was configured with 2.9 GHz Intel Core CPU and 16GB memory; 2. The software platforms were Python 3.8 and pytorch 1.8. The main evaluation indicators of the ear recognition model in this paper were: The schematic diagram of IOU is shown in Figure 6 . The green frame A2 represents the real detection frame, and the red frame A1 represents the prediction frame. The ratio of the intersection and union of the two is used to measure the degree of overlap between the prediction frame and the real frame. IOU is defined as Formula (1). When using IOU to judge whether the detection is correct, a threshold value needs to be set: the commonly used threshold value is 0.5. Therefore, Eardata5 contained a total of 74 videos in 34 categories. The Eardata5 naming rule is personnel number + interference category (earphone, glasses, hair and cap) + movement type (Rotation Motion, RM or Translational Motion, TM) + Left Ear (LE) or Right Ear (RE). For example, "1_erephone_RM_RE" indicates that this video is the interference video information of the right ear rotating 90° during the shooting process of the subject No. 1 rotating clockwise from the −45° direction to the 45° direction under the interference condition of earphone. From Figure 1 we can see that, in order to test the effectiveness of the deep learning model for dynamic human ear recognition, three datasets were used: (1) coco [19] , http://cocodataset.org; (2) USTB [14], http://www.ustb.edu.cn/resb; (3) CCU-DE coco and USTB datasets which are public and widely used in the field of deep learning and static ear recognition. CCU-DE is a static and dynamic ear database developed in this paper. In order to test the practicability and effectiveness of the proposed CCU-DE small sample database, we set up two groups of experiments. The first group of experiments were based on the yolov3 deep learning model. The second group of experiments involved the comparison of the different deep learning models, such as YOLOv3, YOLOv4, YOLOv5, Faster R-CNN and SSD. The experimental parameters were set as follows: 1. The computer was configured with 2.9 GHz Intel Core CPU and 16GB memory; 2. The software platforms were Python 3.8 and pytorch 1.8. The main evaluation indicators of the ear recognition model in this paper were: The schematic diagram of IOU is shown in Figure 6 . The green frame A2 represents the real detection frame, and the red frame A1 represents the prediction frame. The ratio of the intersection and union of the two is used to measure the degree of overlap between the prediction frame and the real frame. IOU is defined as Formula (1). When using IOU to judge whether the detection is correct, a threshold value needs to be set: the commonly used threshold value is 0.5. The test result will divide the classification target as true positives (TP), false positives (FP), false negatives (FN) and true negatives (TN). Figure 1 for human ear recognition requires a large amount of human ear data to train the model. We adopted the method of transfer learning to determine the initial value of the model. Migration learning mainly uses the characteristics of a certain correlation between different classification tasks, which can not only reduce the training time of the model, but also improve the accuracy of deep learning. We first used more than 330,000 images in 80 categories in the COCO dataset to determine the initial value of the model for deep learning models. Then, we used the 10 types 100 static ear pictures of database3 in the USTB to further determine the initial value of the model. Thus, the initial values of the dynamic ear recognition model of the CCU-DE small sample database were determined. In deep learning, the gradient descent method is often used for model training. An epoch refers to the time it takes to send all data into the network to complete a forward calculation and back propagation process. For training sets of different sizes and types, the required epoch size is also uncertain. In this paper, we conducted an experimental study on the influence of epoch value on the training model. In the training of the deep learning model, the training dataset was a picture. The dataset in this paper was a dynamic video, so it was necessary to turn the video into a frame picture. The training set in the experiment came from Eardata3 and Eardata4 in the CCU-DE small sample database. We randomly selected two types whose numbers were 25 and 26 in Eardata3. All eight categories in Eardata4 were selected. The purpose of the selection was to make the experiment more difficult, since Eardata4 was a 180 • rotation and Eardata3 was a 90 • rotation. Ten types of dynamic human ear videos were sampled at two frames per second, and the first frame was taken to form the sample training set. The training samples are shown in Table 10 : 'ear1' is the human ear category of participant No. 1, and 'ear25' to 'ear33' have the same definition. We defined NF as the number of frames for each type of human ear video, i.e., 153 NF in column 3 row 1 indicates that the left ear in the participant No. 1 video has 153 frames. In the actual training process, a certain number of various samples in Table 10 were randomly selected to participate in the training. The number of samples participating in the training was 2063, and accounted for about 63% of the total number of samples: Batchsize = 12, learning_rate = 0.001. Different ear recognition models were trained by the initial value determined in Section 4.4.1, and were obtained by changing the epoch value. Then, 3274 pictures of all samples were used as the test set (including 2063 trained pictures and 1211 untrained pictures). The test results corresponding to different epoch values are shown in Table 11 . Comparing Tables 10 and 11, we can see that the number of ground-truth (3956) in Table 11 is greater than the total number of samples in Table 10 (3274). This is because there were double ears in some human ear images in Table 10 . It can be seen from Table 11 that when epoch = 1100, the TP value was the largest, and the FP value was relatively small. The AP of this model for human ear classification can reach 98.32%, and the average error rate was the lowest. Therefore, it can be seen that the epoch value had a greater impact on the training results of the model. In the model training module, it was necessary to test and compare the recognition results according to the number of sample categories and the total number of samples participating in the training to determine the appropriate epoch value to obtain an ideal training model. Table 10 were tested. The screenshot result of ear1 test videos is shown in Figure 7 . We can see that test videos could be correctly identified. The precision for the left and right ear of ear1 were 1.00 and 0.99, respectively. In order to give a specific performance index evaluation, we took a screenshot of the video in this experiment as a test set and labelled it. The test video selection and frame cut are shown in Table 12 . The test result is shown in Figure 8 . Eardata4 ear1 298 252 550 Eardata3 ear25 231 287 518 Eardata3 ear26 234 317 551 Eardata4 ear27 508 321 829 Eardata4 ear28 201 222 423 Eardata4 ear29 336 385 721 Eardata4 ear30 321 257 578 Eardata4 ear31 415 382 797 Eardata4 ear32 360 373 733 Eardata4 ear33 479 511 990 Total 3383 3307 6690 In order to give a specific performance index evaluation, we took a screenshot of the video in this experiment as a test set and labelled it. The test video selection and frame cut are shown in Table 12 . The test result is shown in Figure 8 . The IOU value of ear1 in Figure 8a was 78.58%, and greater than 50.00%, and therefore could be considered a real test. The final matching result was "MATCH". That is, ear1 could be correctly identified. From Table 12 and Figure 8b we can see that the 6690 human ear test pictures in 10 categories in the test set contained a total of 8144 real frames. This is because some images contained both the left and right ears. Taking ear1 class as an example, the No. 1 participants' video had 550 frames in Table 12 , but the number of ear1 in Figure 8b was 726. The precision of ear1 was 0.97. Figure 8c gives average precision for each type, and mAP was 97.23%. From Figure 8c , we can also see that the precision of ear25 was 1.0 and the precision of ear26 was 0.99. So, we can conclude that the precision in Eardata3 rotated by 90° was greater than Eardata4 rotated by 180°. Eardata4 ear1 298 252 550 Eardata3 ear25 231 287 518 Eardata3 ear26 234 317 551 Eardata4 ear27 508 321 829 Eardata4 ear28 201 222 423 Eardata4 ear29 336 385 721 Eardata4 ear30 321 257 578 Eardata4 ear31 415 382 797 Eardata4 ear32 360 373 733 Eardata4 ear33 479 511 990 Total 3383 3307 6690 Generally, the greater the contrast, the higher the image clarity, and the more vivid the color. Conversely, the lower the contrast, the worse the image clarity, and the detail in the image is worse. The contrast of all pictures in Table 12 underwent enhanced processing. The values of contrasts were 0.9, 0.8, 0.7 and 0.6. The results of different contrast control experiments and mAP experiments are shown in Table 13 . From Table 13 , we can see that, except for ear25 and ear26, the precision of all other ears decreased with decreasing contrast. The next step was to further increase the experimental volume to prove whether the reduction of contrast had an effect on the precision for all dynamic human ears. We can also conclude that contrast had a greater effect on Eardata4 than Eardata3. The IOU value of ear1 in Figure 8a was 78.58%, and greater than 50.00%, and therefore could be considered a real test. The final matching result was "MATCH". That is, ear1 could be correctly identified. From Table 12 and Figure 8b we can see that the 6690 human ear test pictures in 10 categories in the test set contained a total of 8144 real frames. This is because some images contained both the left and right ears. Taking ear1 class as an example, the No. 1 participants' video had 550 frames in Table 12 , but the number of ear1 in Figure 8b was 726. The precision of ear1 was 0.97. Figure 8c gives average precision for each type, and mAP was 97.23%. From Figure 8c , we can also see that the precision of ear25 was 1.0 and the precision of ear26 was 0.99. So, we can conclude that the precision in Eardata3 rotated by 90 • was greater than Eardata4 rotated by 180 • . Generally, the greater the contrast, the higher the image clarity, and the more vivid the color. Conversely, the lower the contrast, the worse the image clarity, and the detail in the image is worse. The contrast of all pictures in Table 12 underwent enhanced processing. The values of contrasts were 0.9, 0.8, 0.7 and 0.6. The results of different contrast control experiments and mAP experiments are shown in Table 13 . From Table 13 , we can see that, except for ear25 and ear26, the precision of all other ears decreased with decreasing contrast. The next step was to further increase the experimental volume to prove whether the reduction of contrast had an effect on the precision for all dynamic human ears. We can also conclude that contrast had a greater effect on Eardata4 than Eardata3. The size of the translation angle has a certain impact on the human ear video recognition effect. Generally speaking, the smaller the translation angle, the better the recognition effect. Conversely, the larger the angle, the worse the recognition effect. This experiment selected eight segments of dynamic human ear translation videos from different angles of ear1 in the untrained Eardata2 from the CCU-DE small sample human ear database under strong light conditions. The simulation results are shown in Table 14 . It can be seen from the results that the smaller the translation angle, the higher the accuracy of human ear recognition. For untrained test sets, high recognition accuracy can also be achieved. So, the human ear recognition model in this paper is very robust to changes in the posture of each angle with translational motion. The experiment in this section was mainly used to simulate the situation in which the human body carries on rotational motion (RM) and drives the human ear to rotate. The experimental samples came from the untrained dynamic human ear video of ear1 under strong light conditions: 90 • rotation in Eardata3, and 180 • rotation in Eardata4. Each angle had one segment for the left and right ears, a total of four segments. The experimental results are shown in Table 15 . It can be seen from the experimental results that the rotation movement had a certain impact on the recognition results of human ears. The greater the rotation angle, the slightly lower the mAP value. However, the mAP value of 180 • rotation was above 98%, which could meet actual needs. This further illustrates that the ear recognition model proposed in this paper has certain robustness. In practical applications, human ears are often occluded in front of the lens, so the robustness of the human ear recognition model is required to be high. Common occlusions include glasses, earphone, cap and hair, etc. In this section of the experiment, common features of video were a 0 • round-trip translation with untrained person No. 33. We selected two videos of Eardata2 under unobstructed conditions and six videos of Eardata5 with glasses, glasses and earphones, and glasses, earphones and a cap. The experimental results are shown in Figure 9 . The precision of No. 33 without occlusion was 1.00, as seen from Figure 9a . The precision of No. 33 with glasses was 0.96 (Figure 9b ). The precision of No. 33 with glasses and earphones was 0.76 ( Figure 9c ). In Figure 9d , ear33 was recognized as ear28. So, it can be seen from the experimental results that the larger the area of human ears occluded, the lower the recognition rate. strong light conditions: 90° rotation in Eardata3, and 180° rotation in Eardata4. Each angle had one segment for the left and right ears, a total of four segments. The experimental results are shown in Table 15 . It can be seen from the experimental results that the rotation movement had a certain impact on the recognition results of human ears. The greater the rotation angle, the slightly lower the mAP value. However, the mAP value of 180° rotation was above 98%, which could meet actual needs. This further illustrates that the ear recognition model proposed in this paper has certain robustness. In practical applications, human ears are often occluded in front of the lens, so the robustness of the human ear recognition model is required to be high. Common occlusions include glasses, earphone, cap and hair, etc. In this section of the experiment, common features of video were a 0° round-trip translation with untrained person No. 33. We selected two videos of Eardata2 under unobstructed conditions and six videos of Eardata5 with glasses, glasses and earphones, and glasses, earphones and a cap. The experimental results are shown in Figure 9 . The precision of No. 33 without occlusion was 1.00, as seen from Figure 9a . The precision of No. 33 with glasses was 0.96 ( Figure 9b ). The precision of No. 33 with glasses and earphones was 0.76 ( Figure 9c ). In Figure 9d , ear33 was recognized as ear28. So, it can be seen from the experimental results that the larger the area of human ears occluded, the lower the recognition rate. In order to further verify that different deep learning models can also be used for dynamic human ear recognition by using the CCU-DE database, we conducted comparative experiments on the different deep learning models. In the experiment, mainstream YOLO series models such as YOLOv3, YOLOv4 and YOLOv5, Faster-R-CNN, and SSD deep learning models were adopted. Figure 10 displays the experimental results of the five models. The results show that the CCU-DE small sample database could be tested by using the different deep learning models and had a high test accuracy. In order to further verify that different deep learning models can also be used for dynamic human ear recognition by using the CCU-DE database, we conducted comparative experiments on the different deep learning models. In the experiment, mainstream YOLO series models such as YOLOv3, YOLOv4 and YOLOv5, Faster-R-CNN, and SSD deep learning models were adopted. Figure 10 displays the experimental results of the five models. The results show that the CCU-DE small sample database could be tested by using the different deep learning models and had a high test accuracy. In this paper, we came to three conclusions. (1) We developed a small-sample human ear database of CCU-DE, containing five human ear databases. CCU-DE fully considers the various complex situations and posture changes of human ear images, such as translation angle, rotation angle, illumination changes, occlusion and interference (glasses, earphones, caps, etc.) and other factors, making the research of dynamic ear recognition more realistic, and increasing the applicability of dynamic ear recognition. (2) The block diagram of the dynamic ear recognition based on deep learning was designed. We adopted the method of transfer learning to determine the initial value of the model, because this can not only reduce the training time of a model, but also improve the accuracy of deep learning. (3) We used different deep learning models to test the CCU-DE small sample database. The experiments we did are shown in Table 16 . The experimental results showed that CCU-DE can be used in studies of dynamic human ear recognition, and it is more conducive to the application of dynamic human ear recognition in real life. In this paper, we came to three conclusions. (1) We developed a small-sample human ear database of CCU-DE, containing five human ear databases. CCU-DE fully considers the various complex situations and posture changes of human ear images, such as translation angle, rotation angle, illumination changes, occlusion and interference (glasses, earphones, caps, etc.) and other factors, making the research of dynamic ear recognition more realistic, and increasing the applicability of dynamic ear recognition. (2) The block diagram of the dynamic ear recognition based on deep learning was designed. We adopted the method of transfer learning to determine the initial value of the model, because this can not only reduce the training time of a model, but also improve the accuracy of deep learning. (3) We used different deep learning models to test the CCU-DE small sample database. The experiments we did are shown in Table 16 . The experimental results showed that CCU-DE can be used in studies of dynamic human ear recognition, and it is more conducive to the application of dynamic human ear recognition in real life. Hybrid face recognition method based on Gabor wavelet transform and VGG convolutional neural network with improved pooling strategy Exploring attention mechanisms based on summary information for end-to-end automatic speech recognition 3D fingerprint recognition based on Ridge-Valley-Guided 3D reconstruction and 3D topology polymer feature extraction Low-power iris recognition system implementation on FPGA with approximate multiplier Ear biometrics in computer vision A brief review of the ear recognition process using deep neural networks Ear Detection under Uncontrolled Conditions with Multiple Scale Faster Region-Based Convolutional Neural Networks Deep learning approach for person identification using ear biometrics Few-shot learning for ear recognition Deep learning for 3D ear detection: Complete pipeline from data generation to segmentation Ear-biometrics for human identification You only look once: Unified, real-time object detection Automated human identification using ear imaging 0: A new large-scale ear images dataset in the wild Agricultural Greenhouses Detection in High-Resolution Satellite Images Based on Convolutional Neural Networks: Comparison of Faster R-CNN, YOLO v3 and SSD A Lightweight YOLOv4 Based SAR Image Ship Detection Deep Learning-based Face Mask Detection Using YoloV5 Dataset Stuff Segmentation Challenge (3) CCU-DE has just been established and is still being perfected. The videos in the database contain a large amount of biometric information other than the human ear. Although written authorization from the participants has been obtained, no links to the archived datasets are publicly available at present. If you need to do related research on human ear recognition, you can contact the author of this article to use the database. Email: 0451lym@163.com and qjr1107007169@163.com. The authors declare no conflict of interest.