key: cord-0792288-7kd7w7jt authors: Wu, Ze-gang; Zheng, Hong-yun; Gu, Jian; Li, Feng; Lv, Rui-long; Deng, Ya-yun; Xu, Wan-zhou; Tong, Yong-qing title: Effects of Different Temperature and Time Durations of Virus Inactivation on Results of Real-time Fluorescence PCR Testing of COVID-19 Viruses date: 2020-08-07 journal: Curr Med Sci DOI: 10.1007/s11596-020-2224-y sha: 85981f18564fe30c01aa39c8eb53e8f3eb80097e doc_id: 792288 cord_uid: 7kd7w7jt The novel Coronavirus SARS-CoV-2 caused an outbreak of pneumonia in Wuhan, Hubei province of China in January 2020. This study aims to investigate the effects of different temperature and time durations of virus inactivation on the results of PCR testing for SARS-CoV-2. Twelve patients at the Renmin Hospital of Wuhan University suspected of being infected with SARS-CoV-2 were selected on February 13, 2020 and throat swabs were taken. The swabs were stored at room temperature (20–25°C), then divided into aliquots and subjected to different temperature for different periods in order to inactivate the viruses (56°C for 30, 45, 60 min; 65, 70, 80°C for 10, 15, 20 min). Control aliquots were stored at room temperature for 60 min. Then all aliquots were tested in a real-time fluorescence PCR using primers against SARS-CoV-2. Regardless of inactivation temperature and time, 7 of 12 cases (58.3%) tested were positive for SARS-CoV-2 by PCR, and cycle threshold values were similar. These results suggest that virus inactivation parameters exert minimal influence on PCR test results. Inactivation at 65°C for 10 min may be sufficient to ensure safe, reliable testing. Numerous infections of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) have occurred in Wuhan, Hubei since December 2019, and the number of infections has rapidly increased [1] . New infections have since occurred in other regions of China and the other countries [2] [3] [4] . The SARS-CoV-2 has been added to the Chinese National Health Committee's list of Class A infectious diseases requiring prevention and control under the Infectious Disease Control Law. As of April 10, 2020, a total of 81 953 confirmed cases and 3339 deaths (4.07%) have been reported nationwide [5] . Since the beginning of the epidemic in late December 2019, SARS-CoV-2 has now spread to all continents, and up to April 10, 2020, the WHO reported 1 521 252 confirmed cases and 92 798 deaths globally (Situation Report-81). Real-time fluorescence PCR detection of SARS-CoV-2 nucleic acids is one of the methods for confirming infection [6] . Due to the highly infectious nature of the virus, staff who perform nucleic acid detection are at great risk of infection and therefore require protective equipment and other measures to minimize this risk. According to the current COVID-19 diagnosis and treatment guidelines, the virus can be inactivated at 56°C for 30 min [7] . Whether this inactivation process affects the PCR results is currently unclear. Therefore, this study compared the results of PCR testing of throat swabs following sample inactivation at different temperature for different periods. We also intended to identify the best inactivation temperature and time duration that can minimize infection risk to laboratory staff without affecting test results. This study was conducted in accordance with the Declaration of Helsinki and approved by the Research Ethics Committee of Renmin Hospital of Wuhan University. The requirement for written informed consent was waived given the context of emerging infectious diseases. Throat swabs from a convenience sample of 12 patients suspected of being infected with SARS-CoV-2, aged 32-75 years (average, 52.57 years) in Renmin Hospital of Wuhan University were collected on February 13, 2020. All 12 patients were living in Wuhan and had fever, fatigue, and dry cough. Swabs were placed immediately in vials containing 3 mL of preservation solution containing antibiotics, protein protection agent, buffer, glycerin, and nuclease inhibitors (Health Gene Technologies, China) and stored at room temperature (20-25°C) until inactivation (see below). The diagnostic criteria for suspected cases of COVID-19 were consistent with the New coronavirus pneumonia diagnosis and treatment, a clinical guideline and database (trial version 6) [7] . We used sterile EP tubes to divide each sample into 12 tubes, 300 µL per tube. The aliquots were incubated in water baths at room temperature for 60 min (control); at 56°C for 30, 45, or 60 min; or at 65, 70, or 80°C for 10, 15, or 20 min. Nucleic acid was extracted using a Smart Labassist-32 type nucleic acid extraction/purification analyzer (TANBead, Taiwan, China). Then levels of mRNA were determined in all samples using real-time fluorescence PCR on a LightCycler 480 fluorescence PCR system (Roche, Switzerland). Reagents and primers were purchased from the SARS-CoV-2 ORF1ab/N Gene Dual Nucleic Acid Detection Kit (Huirui Biotechnology, Shanghai, China), which contained forward primer 5′-TCAGA-ATGCCAATCTCCCCAAC-3′, reverse primer 5-AA-AGGTCCACCCGATACATTGA-3′ and probe 5′-CY5-CTAGTTACACTAGCCATCCTTACTGC-3′ BHQ1). Each PCR reaction contained 7.5 μL of PCR reaction solution, 5 μL of ORF1ab/N gene reaction solution, 1.5 μL of enzyme mixture, and 11 μL of nucleic acid extract. Reactions were subjected to 50°C for 15 min, 95°C for 5 min, followed by 45 cycles of 95°C for 10 s, and 55°C for 45 s. According to the manufacturer's instructions, the criterion for judging the results is cycle threshold (Ct) <40. Data were analyzed using SPSS 19.0 (IBM, USA). Data were expressed as mean±SD. Data distribution was assessed using the Kolmogorov-Smirnov test. Analysis of variance was used to compare Ct values between groups. Differences were considered significant when P<0.05. Based on analysis of the control samples, 7 of 12 (58.3%) patients were tested positive for SARS-CoV-2 nucleic acid (table 1). One patient was classified as having a high concentration of nucleic acid (Ct <30), 3 as having a medium concentration (Ct, 30-35), and 3 as having a low concentration (Ct, 36-40). Inactivated samples showed similar Ct values and similar overall positive/negative results as the control samples. The SARS-CoV-2 RNA was processed with 4 temperature values and 3 time durations were set at each temperature value [56°C (30, 45, and 60 min); 65°C/70°C/80°C (10, 15, and 20 min). The Ct values of the test results were similar, and there were no statistically significant differences among the time points (P>0.05) (table 2) . Similarly, when the processing time was uniform but the processing temperature was different, the test results were not statistically different (P>0.05) (table 3) . In addition, the 7 positive samples included high-concentration, medium-concentration, and lowconcentration samples, and the results showed that each concentration curve showed a typical fluorescence quantitative amplification curve ( fig. 1 ). These results suggest minimal influence of inactivation temperature or duration on levels of viral RNA prior to PCR testing. With the sudden outbreak of the new SARS-CoV-2 and its rapid spread, the health of the general public is seriously threatened [8] . The focus of COVID-19 prevention and control is mainly on early detection, diagnosis, isolation, and treatment. Realtime fluorescence PCR to detect viral nucleic acid is one of the major diagnostic methods [9] . Given the highly infectious nature of the SARS-CoV-2, it is of great importance to find ways to reduce risk of virus spread among laboratory personnel. This will have important implications in carrying out SARS-CoV-2 testing worldwide. Previous studies have shown that SARS-CoV was completely inactivated by heating at 56°C for 60 min or longer [10] . Similarly, SARS-CoV-2 is sensitive to heat and can be effectively inactivated at 56°C for 30 min [7] . In this study, we found that different inactivation temperatures and different inactivation time durations had no significant effect on PCR detection of SARS-CoV-2 RNA. This may be related to the protective effects of the preservation solution, which contains antibiotics, protein protection agent, buffer, glycerin, and nuclease inhibitors. The inactivation temperature should be high enough to eliminate virus but not high enough to damage viral RNA or the PCR tube. In order to improve the laboratory testing efficiency as much as possible, the inactivation time duration should not be too long. Based on our results, we suggest virus inactivation at 65°C for 10 min. This recommendation should be verified using larger number of samples and different reagent test kits. A rapid advice guideline for the diagnosis and treatment of 2019 novel coronavirus (2019-nCoV) infected pneumonia (standard version) novel coronavirus of pneumonia in Wuhan, China: emerging attack and management strategies Korean Society of Epidemiology 2019-nCoV Task Force Team. An interim review of the epidemiological characteristics of 2019 novel coronavirus First Case of 2019 Novel Coronavirus in the United States Chinese National Health Committee. The latest epidemic situation of the new coronavirus pneumonia at 24:00 on Apirl Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR General Office of the Chinese National Health Commission. New coronavirus pneumonia diagnosis and treatment, a clinical guideline and database (trial version 6) (Chinese) Coronavirus: covid-19 has killed more people than SARS and MERS combined, despite lower case fatality rate Emergence of a Novel Coronavirus Disease (COVID-19) and the Importance of Diagnostic Testing: Why Partnership between Clinical Laboratories, Public Health Agencies, and Industry Is Essential to Control the Outbreak Inactivation of SARS Coronavirus by Means of Povidone-Iodine, Physical Conditions and Chemical Reagents I declare on behalf of my co-authors and myself that we do not have any conflict of interest to declare.