key: cord-0789326-kkkdlnd5 authors: Torlasco, Camilla; Castelletti, Silvia; Soranna, Davide; Volpato, Valentina; Figliozzi, Stefano; Menacho, Katia; Cernigliaro, Franco; Zambon, Antonella; Kellman, Peter; Moon, James C.; Badano, Luigi P.; Parati, Gianfranco title: Effective Study: Development and Application of a Question‐Driven, Time‐Effective Cardiac Magnetic Resonance Scanning Protocol date: 2021-12-31 journal: J Am Heart Assoc DOI: 10.1161/jaha.121.022605 sha: c78612e77f5921a3a09fe3b2a579057f05e13cbd doc_id: 789326 cord_uid: kkkdlnd5 BACKGROUND: Long scanning times impede cardiac magnetic resonance (CMR) clinical uptake. A “one‐size‐fits‐all” shortened, focused protocol (eg, only function and late‐gadolinium enhancement) reduces scanning time and costs, but provides less information. We developed 2 question‐driven CMR and stress‐CMR protocols, including tailored advanced tissue characterization, and tested their effectiveness in reducing scanning time while retaining the diagnostic performances of standard protocols. METHODS AND RESULTS: Eighty three consecutive patients with cardiomyopathy or ischemic heart disease underwent the tailored CMR. Each scan consisted of standard cines, late‐gadolinium enhancement imaging, native T1‐mapping, and extracellular volume. Fat/edema modules, right ventricle cine, and in‐line quantitative perfusion mapping were performed as clinically required. Workflow was optimized to avoid gaps. Time target was <30 minutes for a CMR and <35 minutes for a stress‐CMR. CMR was considered impactful when its results drove changes in diagnosis or management. Advanced tissue characterization was considered impactful when it changed the confidence level in the diagnosis. The quality of the images was assessed. A control group of 137 patients was identified among scans performed before February 2020. Compared with standard protocols, the average scan duration dropped by >30% (CMR: from 42±8 to 28±6 minutes; stress‐CMR: from 50±10 to 34±6 minutes, both P<0.0001). Independent on the protocol, CMR was impactful in ≈60% cases, and advanced tissue characterization was impactful in >45% of cases. Quality grading was similar between the 2 protocols. Tailored protocols did not require additional staff. CONCLUSIONS: Tailored CMR and stress‐CMR protocols including advanced tissue characterization are accurate and time‐effective for cardiomyopathies and ischemic heart disease. Time-Effective, Question-Driven CMR Protocol imaging resources optimization. The COVID-19 pandemic has put additional pressure on the health care systems, because of the need to reschedule cancelled tests while at the same time carrying on with routine activity and ensuring additional safety measures, including social distancing and ad-hoc equipment sanitation. To reduce CMR duration, industry has contributed technological advances, including faster reconstruction, parallel imaging, compressed sensing, and automated workflows. These strategies are effective but limited by the need for costly hardware and software upgrades. On the other hand, protocol workflow optimization and image selection tailored to the clinical question effectively reduce acquisition times, while retaining diagnostic performance. Examples are a noncontrast, 6-minute, 10-breath hold CMR protocol for the assessment of cardiac and liver iron load, myocardial function, and extracardiac anatomy in patients with thalassemia, 4,5 a shortened cardiothoracic-MR protocol to rule out myocardial inflammation, and pulmonary embolism in half of the time of a standard CMR, 6 and 2 stress-CMR protocols for the evaluation of inducible ischemia in <30 minutes. 7, 8 Although very time-effective, the main limitation of these protocols is the lack of transferability to other cardiac conditions. 4, 6 Finally, in the INCA-Peru study, an 18-minute CMR protocol for the evaluation of cardiomyopathies, consisting of left ventricle (LV) long-and short-axis cines, aortic valve cines, and late gadolinium enhancement imaging, was developed and tested. 9 The authors reported a CMR-driven change in management in 56% of patients, consistent with that reported in international registries, 10 confirming the importance of late gadolinium enhancement within the imaging portfolio and improving both CMR feasibility and cost-effectiveness in Low-Middle Income Countries. 9 Menacho's protocol is suitable for a wide range of indications, including all cardiomyopathies and viability assessment. Nevertheless, 1-way scans were shortened was by the omission of more advanced tissue characterization such as mapping. However, these still have a role providing unique information with diagnostic and prognostic relevance for scenarios including the evaluation of LV hypertrophy, diffuse fibrosis, inflammatory heart conditions, infiltrative diseases, and myocardial infarction with nonobstructed coronary arteries, and thus should not be omitted. [11] [12] [13] Therefore, we explored the use of a more complete, but still abbreviated, tailored CMR and stress-CMR strategy for key indications (focusing on cardiomyopathies and ischemic heart disease), with targeted advanced tissue characterization (T1 mapping and extracellular volume, fat, and edema modules) and additional cines (right ventricle [RV] module), 12 but with substantially shorter scan times, aiming for no more than 10 minutes longer than Menacho's rapid CMR and at least 10 minutes shorter than conventional imaging. The data that support the findings of this study are available from the corresponding author upon reasonable request. We applied the new CMR protocols to the patients referred for either a CMR or a stress-CMR to our Institution from June 1 to July 29, 2020 (tailored CMR group). A control group consisted of a sample of standard CMR and stress-CMR scans performed from February 1, 2019 to January 30, 2020 (standard CMR group). Patients of the standard CMR group were similar to patients of the tailored CMR group in terms of age, sex, proportion of first diagnostic scan versus follow-up scans, and presence of arrhythmias. Both groups included outpatients referred by Auxologico staff cardiologists and external physicians, as well as Auxologico inpatients. The study was retrospective, approved by the local Ethics Committee, and conducted in accordance with the Helsinki Declaration. All patients signed an informed consent for "general" research purposes, at the time of CMR. All patients were required to bring a copy of their previous cardiology records on the CMR day, including reports of ECGs, echocardiography, exercise tests, Holter ECG, and clinical letters. While the patient underwent cannulation, an experienced cardiologist (C.T. or S.C.) reviewed the documents and protocoled the scan, depending on the clinical indication, and accordingly to current guidelines 12 ( Figure 1 ; Table S1 ). The same physician reviewed images before contrast administration and at the end of the scan for quality and to evaluate whether additional images were needed, and issued the clinical report ( Figure S1 ). Images were acquired on a 1.5-T scanner (Avanto Fit; Siemens Healthineers, Erlangen, Germany) using dedicated cardiac software, phase-array surface receiver coil, and ECG triggering. A standardized protocol was carried out in all patients (Figure 1 ), including (1) localizers, bright-blood and half-Fourier acquisition singleshot turbo spin echo transversal stack; (2) long-axis cines (2-, 3-, and 4-chamber); (3) a native short-axis midventricular T1 map; (4) bolus of gadolinium-based contrast agent (Gadovist; Bayer Healthcare, Switzerland) of 0.1 mmol/kg; (5) stack of short-axis cines, a second LV outflow tract cine, aortic valve short-axis cine, and RV 2-chambers cine; (6) late gadolinium enhancement images (3 LV long-axis and a short-axis stack); and (7) Torlasco et al Time-Effective, Question-Driven CMR Protocol a postcontrast short-axis midventricular T1 map and extracellular volume map. Stress-CMR scan protocol also included in-line quantitative perfusion mapping 14 acquired during stress (at peak adenosine infusion 12 ) and at rest, with an iv gadolinium-based contrast agent bolus (0.05 mmol/ kg during stress and rest acquisition, respectively). Rest perfusion images were acquired >5 minutes after stress. During this time, short-axis stack cines were acquired. LV outflow tract, aortic valve, and RV 2-chamber cine views were acquired after rest perfusion. Cines used a breath-hold steady-state freeprecession sequence. T1 maps used Modified Look-Lockers Inversion recovery images (MOLLI, Siemens WIP1041). Late gadolinium enhancement images were acquired >5 minutes after contrast administration by motion-corrected segmented inversion-recovery and phase-sensitive-inversion-recovery gradient-echo sequence. 15 Inversion-time to null normal myocardium was optimized on Look-Locker images. Postcontrast T1 maps were acquired >10 minutes postcontrast. Additional sequences, acquired on the basis of the clinical need, included (1) edema module (black blood Short Tau Inversion-Recovery, 3-long and 3-short-axis views, precontrast; (2) fat module (multi-echo Dixon fat-water separated images 16 ), 3-short and 3-long-axis views, precontrast; and (3) RV cine outflow tract view, inflow-outflow tract view, transverse stack. 12 Images were analyzed with a dedicated software (Argus, Siemens Healthineers). Image quality was graded as: (1) poor (inadequate to answer the clinical question); (2) moderate (presence of artifact not significantly affecting diagnostic performance); and (3) good (optimal image quality). Scan duration was calculated from the timestamp of the first to the last images. Follow-up was performed at 6 to 12 months reviewing available clinical records and contacting the referring physicians. CMR was considered to have a clinical impact when it resulted in (1) diagnostic consequences (ie, either a confirmation of a previously suspected diagnosis, such as a diagnosis of hypertrophic The "basic tailored protocol," adapted from Menacho et al, 9 consists of localizers, left ventricular long-axis cines, short-axis cines, 2-chamber right ventricle, LV outflow tract and aortic valve cines, late gadolinium enhancement imaging, 1 midventricular short-axis native T1 mapping slice and corresponding extracellular volume (ECV) assessment, and lasts ≈20 minutes. Adding LVOT, aortic valve and 2-chambers cine views and advanced tissue characterization (either edema module or fat module plus right ventricle focused cine), the whole protocol can be completed in <30 minutes. Adding both perfusion and advanced tissue characterization, the protocol lasts <35 minutes. *Different additional images were added depending on clinical need as illustrated in Table S1 . Cine, balanced steady-state free precession cine sequences; ECV, extracellular volume; GBCA indicates gadolinium-based contrast agent; LGE, late gadolinium enhancement; LV, left ventricle; LVNC, left ventricular non-compaction; LVOT, LV outflow tract; MINOCA, myocardial infarction with nonobstructed coronary arteries; RV, right ventricle; and TI, inversion time. Time-Effective, Question-Driven CMR Protocol cardiomyopathy in patients referred for differential diagnosis of LV hypertrophy) or changing the current diagnosis (eg, diagnosis of active cardiac sarcoidosis in patient referred for ventricular arrhythmias); (2) therapeutic consequences, evaluated at a 6-to 12month follow-up, ie, (1) change in medication; (2) ordering an invasive procedure; (3) hospital admission/ discharge; or (4) ordering new testing because of the CMR findings. 10 To assess the impact of advanced tissue characterization, the scans were processed as follows ( Figure 2 ). The tailored CMR scans were anonymized and reported twice, once in their original form and once excluding all advanced tissue characterization images and RV cines, according to the rapid scanning approach. The control group scans were anonymized and reported 3 times: (1) with all the sequences originally acquired as per the standard protocol; (2) with a set of sequence simulating the tailored CMR approach; and (3) excluding all advanced tissue characterization images and RV cines, simulating the rapid scanning approach. C.T./S.C. and F.C. (2 cardiologists and a radiologist, all with >5 years CMR experience) acquired and read all the scans for clinical purposes. V.V./S.F. performed all the "research" reads. Neither V.V. nor S.F. took part in images acquisition/report for clinical purposes, because they did not work at Auxologico at the time of scanning. Scans were not randomized but at least 1 month passed between 1 read and the other. The order was as follows: (1) simulated rapid CMR (from both standard and tailored CMR); (2) tailored CMR (full set of images) and standard CMR (full set of images); and (3) simulated tailored CMR (from standard CMR). Simulated tailored CMR (from standard CMR) was read last because it was an additional read required during a revision. Between read 2 and 3, >3 months passed. V.V. and S.F. were blinded to the original acquisition (ie, if the scan was protocoled and acquired as a standard CMR or a tailored CMR) in all cases. They were made aware of the referral question and asked to make a diagnosis and express a degree of confidence in it (expressed as "poor," "moderate," and "strong"). Then, concordance in the diagnosis between the "clinical" and the "research" reports was assessed, along with changes in confidence related to the different protocols. Continuous variables are shown as means and SD or median and interquartile range for non-normally distributed data, and categorical ones as absolute and relative The study consisted of 222 patients, 85 in the tailored CMR group and 137 in the standard CMR group. Of the tailored CMR group, 2 were excluded because of scanner malfunction, leaving 83 patients. Forty-four patients (20%) were lost at follow-up: 32 (23%) in the standard CMR group and 12 (14%) in the tailored CMR group. Clinical indications for CMR were (1) suspected cardiomyopathy, myocarditis, and myocardial infarction with nonobstructed coronary arteries (n=128; 58%); (2) assessment of inducible ischemia and/or viability (n=43; 20%); (3) research scans in patients with Brugada syndrome and heart failure with preserved ejection fraction (n=30; 14%); (4) suspected athlete's heart (n=9; 4%); and (5) other, including cardiac mass, iron overload, and family history of sudden cardiac death (n=10; 5%). No statistically significant difference in the prevalence of each indication among the groups was observed (Table 1) . Among the 220 scans included in the study, 218 (99%) were of diagnostic quality, with 164 graded as of good quality (75%). Arrhythmias and poor breath-holding accounted for most of the 53 moderate quality scans (n=27: arrhythmic patients; n=14: poor breath-holding). There were no statistically significant differences between the tailored and the standard CMR scan groups in term of images quality (Table 1 ). The median scan time duration in the tailored CMR group was 28 (24-30) minutes for CMR (minimum and maximum duration: 18 and 43 minutes) and 33 (30-36) minutes for stress-CMR (minimum and maximum duration: 26 and 48 minutes). The median scan time duration in the standard CMR group was 43 (38-49) minutes for CMR (minimum and maximum duration: 15 and 64 minutes) and 48 (42-56) minutes for stress-CMR (minimum and maximum duration: 37 and 85 minutes). Compared with the standard CMR group, statistically significant reductions in the average scan duration of 34% in CMR and 33% in stress-CMR were observed ( Table 1) . Native T1 maps and extracellular volume were acquired in all patients. Additional advanced tissue characterization and cine were performed globally in 160 patients (70%): 104 patients (76%) in the standard CMR group and 56 (67%) in the tailored CMR group, respectively (P=0.20). There was consensus on all diagnoses reached. Advanced tissue characterization increased the confidence degree in the diagnosis in 45% of cases. This percentage was similar both as reported by the operators who issued the clinical reports and those who performed the second read (Table 1) . Also, we noted no statistically significant differences in confidence in diagnosis between the simulated tailored CMR and the standard CMR (Table S3) . This study is a proof-of-concept exploring the feasibility and accuracy of a question-driven CMR scan protocol, comprehensive of advanced tissue characterization, to evaluate adult cardiomyopathies or viability in <30 minutes, and the presence of inducible ischemia in <35 minutes. Reducing scan times is a priority for the CMR community. Rapid CMR protocols have been pioneered in Torlasco et al Time-Effective, Question-Driven CMR Protocol low-middle income countries where the main issue is CMR sustainability for health care systems. In high resource settings, where the needs are similar but less explicit, and may focus on accessibility, cost, and patient comfort in decision making between competing modalities, rapid CMR diffusion is still limited. Indeed, available abbreviated protocols are either designed to assess a single disease with focused, dedicated sequences, and thus lack transferability to other cardiac conditions, or are designed to assess a broad range of diseases using a minimal set of sequences, and thus may miss information. 4, 6, 7, 9 With our study, we demonstrated that careful sequence selections based on clinical need, rather than a "one-size-fits-all" approach, allows performance of guideline-compliant advanced tissue characterization 12 in a workflow-optimized protocol, reducing scanning time by >30% compared with standard scanning time. We also demonstrated that advanced tissue characterization, as targeted here, strengthened the confidence in diagnosis in >45% of cases, and thus is worth performing. Finally, the data show that CMR impact in our cohort, defined as CMR-driven changes in diagnosis and management, was similar to that reported in international registries. 10 Compared with previous experiences in the Low-Middle Income Countries, 9 we observed a lower number of unexpected diagnosis and a higher number of invasive procedures/heart surgery led by the CMR results. These differences are likely because of the different health care accessibility in Italy versus Low-Middle Income Countries. The results, both in terms of added value of advanced tissue characterization and impact of CMR, are similar in the standard CMR group and in the tailored CMR group, suggesting that, in patients with cardiomyopathies and in those undergoing stress-CMR, the accuracy was unaffected by the sequences selection (ie, the reduction in scan times comes at no cost in terms of diagnostic performance). Following the data collection, the routine application of these tailored protocols has significantly impacted our practice. We have been able to increase the scans volume by 10% (with another 10% increase planned with the ease of pandemic-related safety measures), and to dedicate an average of 5 minutes/patient to research images acquisition. Indeed, the time needed to review patients' medical records and to select additional images does not significantly affect the workflow: protocoling only requires a few minutes (although we did not quantify it), and all activities are carried out by the usual medical staff and clinical reports signed within the day. Study limitations include that we used state-of-theart pulse sequences made available by the National Institutes of Health and Siemens Healthineers through research agreements. These were used primarily to increase image diagnostic performance rather than save time, although they will have reduced the need for repeat sequences in some cases. 15 We also acknowledge that our protocol requires significant expertise in clinical cardiology to identify the minimal effective sequences set. Since our study is monocentric, and the pandemic prevented us from acquiring concurrent controls, future research should include tailored CMR testing in other centers. Also, there was a high dropout rate, especially in the control group scans. Finally, the sample size was inadequate to assess the individual contribution of different advanced tissue characterization sequences. There was a need for higher throughput, which was driven by COVID-19 service pressures. By means of workflow optimization and selective sequence choices, we show that tailored CMR including stress and full tissue characterization as needed can fully answer clinical questions yet reduce average scan duration >30% for the key referral indications of cardiomyopathy and ischemic heart disease. This has wide potential benefits for global CMR delivery. SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance Magnetic resonance perfusion or fractional flow reserve in coronary disease Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary artery disease Trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial Ultrafast magnetic resonance imaging for iron quantification in thalassemia participants in the developing world: the TIC-TOC Study (Thailand and UK International Collaboration in Thalassaemia Optimising Ultrafast CMR) Use of an accelerated protocol for rapid analysis of iron overload in the heart and liver: the All Iron Detected (AID) Multicenter Study How to perform a cardio-thoracic magnetic resonance imaging in COVID-19: comprehensive assessment of heart CMR first-pass perfusion for suspected inducible myocardial ischemia Rapid Cardiovascular Magnetic Resonance for Ischemic Heart Disease Investigation INCA (Peru) Study: impact of non-invasive cardiac magnetic resonance assessment in the developing world European Cardiovascular Magnetic Resonance (EuroCMR) registry-multinational results from 57 centers in 15 countries Potential for rapid and cost-effective cardiac magnetic resonance in the developing (and Developed) World Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update Contemporary diagnosis and management of patients with myocardial infarction in the absence of obstructive coronary artery disease: a scientific statement from the Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification Motion-corrected free-breathing LGE delivers high quality imaging and reduces scan time by half: an independent validation study Multiecho dixon fat and water separation method for detecting fibrofatty infiltration in the myocardium None. None. Tables S1-S3 Figure S1 SUPPLEMENTAL MATERIAL The 137 scans constituting the control group were anonymized and exported three times: 1) with all the sequences originally acquired ("standard protocol"); 2) excluding all advanced tissue characterization images and RV cines, according to the rapid scanning approach ("simulated rapid protocol"); 3) including a set of sequence according to the tailored CMR approach ("simulated tailored protocol"). Then, two CMR-experienced cardiologists (VV and SF) reported independently half the scans each. Each time they were made aware of the referral question and asked to make a diagnosis and express a degree of confidence in it (expressed as "poor", "moderate", "strong"). Confidence degree in the diagnosis in each group are reported in the table.Wilcoxon Signed-Rank Test was used to test the differences in diagnosis confidence among the groups. Bonferroni correction was applied to counteract the problem of multiple comparisons. The confidence degree was higher in the standard protocol compared to the rapid CMR, but was unchanged between the tailored and the standard CMR. Medical records review and CMR protocolling is performed immediately before the scan. Images are reviewed by a CMR doctor before contrast administration and before ending the scan. Tailored CMR protocolling did not increase the staff needed nor the permanence in the department.