key: cord-0789147-dg2f0g38 authors: Li, Lynne; Lowe, Christopher F.; Ritchie, Gordon; Stefanovic, Aleksandra; Champagne, Sylvie; Romney, Marc G.; Leung, Victor; Matic, Nancy title: SARS‐CoV‐2 molecular testing for the diagnosis of COVID‐19: One test does not fit all date: 2020-09-30 journal: J Med Virol DOI: 10.1002/jmv.26532 sha: a138381012906cb0c500bc9a9232ac0084fef6a5 doc_id: 789147 cord_uid: dg2f0g38 We read with interest the study by Chu et al., in which SARS-CoV-2 was detected in only 30 of 54 (56%) of healthcare workers (HCW) by real-time reverse transcription polymerase chain reaction (RT-PCR) in upper respiratory tract (URT) specimens. This article is protected by copyright. All rights reserved. To the Editor, We read with interest the study by Chu et in upper respiratory tract (URT) specimens. 1 At our institution, we similarly had a case of a healthy 33-year-old female HCW who developed fevers after working several weeks in clinical assessment areas including the COVID-19 ward where appropriate personal protective equipment was used. Despite high suspicion for COVID-19, two nasopharyngeal swabs (NPS) tested negative on days 2 and 4 of illness using a laboratory-developed assay targeting genes for the envelope (E) protein and RNA-dependent RNA polymerase. 2 Nevertheless, she continued home self-isolation given ongoing symptoms. In the 2nd week of illness, she developed anorexia, nausea, and vomiting but still lacked respiratory symptoms. Due to persisting suspicion for COVID-19, a third NPS and paired 1 ml saliva specimen was collected on illness day 9. NPS was tested on another platform using the cobas® SARS-CoV-2 test (Roche) targeting E and Orf1a genes. Saliva was tested using the LightMix® ModularDx SARS-CoV (COVID19) E-gene assay (TIB Molbiol). This third NPS tested Clinical characteristics of 54 medical staff with COVID-19: a retrospective study in a single center in Wuhan Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR Variation in false-negative rate of reverse transcriptase polymerase chain reaction-based SARS-CoV-2 tests by time since exposure Suboptimal biological sampling as a probable cause of false-negative COVID-19 diagnostic test results Inappropriate nasopharyngeal sampling for SARS-CoV-2 detection is a relevant cause of false-negative reports Sensitivity of nasopharyngeal swabs and saliva for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Comparing nasopharyngeal swab and early morning saliva for the identification of SARS-CoV-2 Antibody tests for identification of current and past infection with SARS-CoV-2 Combination of serological total antibody and RT-PCR test for detection of SARS-COV-2 infections Epidemiological, clinical and virological characteristics of 74 cases of coronavirus-infected disease 2019 (COVID-19) with gastrointestinal symptoms