key: cord-0787437-cwswmoto authors: Ben-Assa, Nadav; Naddaf, Rawi; Gefen, Tal; Capucha, Tal; Hajjo, Haitham; Mandelbaum, Noa; Elbaum, Lilach; Rogov, Peter; King, Daniel A; Kaplan, Shai; Rotem, Assaf; Chowers, Michal; Szwarcwort-Cohen, Moran; Paul, Mical; Geva-Zatorsky, Naama title: Direct on-the-spot detection of SARS-CoV-2 in patients date: 2020-07-16 journal: Exp Biol Med (Maywood) DOI: 10.1177/1535370220941819 sha: 5ce97aacf236a9cbac4393e43c83488effb9b191 doc_id: 787437 cord_uid: cwswmoto Many countries are currently in a state of lockdown due to the SARS-CoV-2 pandemic. One key requirement to safely transition out of lockdown is the continuous testing of the population to identify infected subjects. Currently, detection is performed at points of care using quantitative reverse-transcription PCR, thus requiring dedicated professionals and equipment. Here, we developed a protocol based on reverse transcribed loop-mediated isothermal amplification for the detection of SARS-CoV-2. This protocol is applied directly to SARS-CoV-2 nose and throat swabs, with no RNA purification step required. We tested this protocol on over 180 suspected patients, and compared the results to those obtained using the standard method. We further succeeded in applying the protocol to self-collected saliva samples from confirmed cases. Since the proposed protocol can detect SARS-CoV-2 from saliva and provides on-the-spot results, it allows simple and continuous surveillance of the community. IMPACT STATEMENT: Humanity is currently experiencing a global pandemic with devastating implications on human health and the economy. Most countries are gradually exiting their lockdown state. We are currently lacking rapid and simple viral detections, especially methods that can be performed in the household. Here, we applied RT-LAMP directly on human clinical swabs and self-collected saliva samples. We adjusted the method to allow simple and rapid viral detection, with no RNA purification steps. By testing our method on over 180 human samples, we determined its sensitivity, and by applying it to other viruses, we determined its specificity. We believe this method has a promising potential to be applied world-wide as a simple and cheap surveillance test for SARS-CoV-2. During a pandemic, surveillance is crucial for minimizing viral spread. The common and approved detection method used worldwide requires professional experience in sampling, carrying out the reaction and analyzing the results. Moreover, it requires dedicated machines and chemical reagents, as well as sophisticated sample collection and transport logistics. Due to these labor-intensive Humanity is currently experiencing a global pandemic with devastating implications on human health and the economy. Most countries are gradually exiting their lockdown state. We are currently lacking rapid and simple viral detections, especially methods that can be performed in the household. Here, we applied RT-LAMP directly on human clinical swabs and selfcollected saliva samples. We adjusted the method to allow simple and rapid viral detection, with no RNA purification steps. By testing our method on over 180 human samples, we determined its sensitivity, and by applying it to other viruses, we determined its specificity. We believe this method has a promising potential to be applied world-wide as a simple and cheap surveillance test for SARS-CoV-2. and cumbersome requirements, the number of detection tests performed per day is limited. As such, many patients in the community are not sampled, let alone sampled frequently. Such limited surveillance necessitates global and strict quarantine requirements, which threaten the global economy. Given that detection is key, a simple and easy detection method, preferably one that can be performed and interpreted on-the-spot, could help relieve current limitations, and thus contribute to a safe and efficient lockdown exit strategy. Accordingly, rapid and simple serological tests that can, in principle, be conducted at home are being developed. 1 However, such tests for anti-viral antibodies can only be detected several days after infection onset, and can persist even after clearance of the virus, when a patient is no longer contagious. 2 As such, the presence of antibodies detected in such home-kits may only provide an indirect indication of previous viral exposure rather than reporting on actual viral load, a critical parameter for minimizing the spread of SARS-CoV-2. At present, the gold standard detection method of viral nucleic acids in patients is performed in laboratories by professionals. As opposed to antibody testing, detection of viral RNA offers a direct measure of a patient's contagiousness. At this point in the current COVID-19 pandemic, it is clear that the availability and throughput of standard methods for viral nucleic acid detection are limited both in terms of resources, and accessibility to the community. Standard methods used for detecting viral RNA in patients include RNA purification, reverse transcription, and quantitative PCR (RT-qPCR). These processes are time-consuming, require multiple biochemical reagents, lab-grade instruments, and trained professionals. 3 Fortunately, alternative molecular biology methods can overcome these limitations. Colorimetric loop-mediated isothermal amplification (LAMP) is one such method. 4 Reverse-transcribed (RT)-LAMP is performed at a single, constant temperature for one-step reverse transcription and genomic material amplification. This reaction is based on three pairs of primers that produce stem-loop DNA structures, which serve as templates for exponential amplifications. RT-LAMP provides results that can be visualized by color change, thereby eliminating the need for sophisticated lab equipment other than a constant heat source (for graphical presentation, see Figure 1 (a)). [5] [6] [7] The colorimetric detection in this method is based on the pH-sensitive dyephenol red. Incorporation of dNTPs during DNA amplification results in accumulation of protons that reduces the pH in the reaction buffer and can be detected by a color change. In acidic pH, phenol red changes color to yellow. 8 Here, we adjusted RT-LAMP for the detection of SARS-CoV-2 RNA directly from clinical diagnostic swabs sampled from human patients, without any RNA purification steps. To evaluate the validity of our method, we compared our results to those obtained by the approved testing method at the Rambam Health Care Campus (RHCC) hospital. Patient throat and nose swabs were collected and transferred to one tube by field healthcare workers and sent to the Virology laboratory at the Rambam Health Care Campus, Haifa, Israel. The swabs were stored in 1-2 mL universal transfer media (UTM). Saliva samples were self-collected directly into sterile cups and kept at 4 C until tested. Viral RNA was extracted using one of three automated nucleic acid extraction systems (easyMAG/EMAG (Biomeriuex), magLEAD 5bL (Precision System Science) or MagEx (STARlet)), from a mixture containing 2 mL lysis buffer, 0.5 mL sample and 50 mL elution buffer or 270 mL lysis buffer, 130 mL sample and 50 mL elution buffer or 300 mL lysis buffer, 400 mL sample and 50 mL elution buffer, respectively. Following viral RNA extraction, RT-qPCR was performed using one of two commercial kits (Allplex 2019-nCoV (Seegene) or real-time fluorescent RT-PCR Kit for Detecting SARS-2019-nCoV (BGI)), according to the manufacturer's instructions. Additional RT-qPCR reaction mix was created manually using custom-made primers (see Table 1 ). 4, 9 Probe IC was synthesized to present a 5'-FAM/CY5 fluorophore moiety and a 3'-ZEN/IBFQ quencher. Each of the manual reactions contained 2X Ag-Path One-step mix (12.5 mL; Ambion), primers (1 mL), reverse transcriptase (1 mL; SOURCE), previously extracted sample RNA (5 mL), and H 2 O to a final volume of 25 mL. All RT-qPCR reactions were executed in either a Quantstudio (Thermo Fisher Scientific) or CFX96 (Bio-Rad) RealTime PCR machine under the following conditions: 30 min at 50 C, 10 min at 95 C, and 45 cycles of a two-step incubations comprising a 15 s step at 95 C and a 30 s step at 55 C. Fluorescence was measured during step 2 of each cycle. Samples in UTM (5 mL) were diluted in 40 mL DNase RNase free water (Biological Industries, 01-869-1B) containing 2 mL of Proteinase K (final concentration, 1.22 mg/mL; Seegene, 744300.4.UC384) and incubated at room temperature for 15 min. Proteinase K was inactivated by incubating the reaction tubes at 95 C for 5 min. Next, a colorimetric RT-LAMP reaction was performed in a total volume of 20 mL per reaction using 10 mL WarmStart Colorimetric LAMP 2X Master Mix (New England BioLabs, M1800), 2 mL primers mix (see Table 1 ), 1 mL guanidine hydrochloride (final concentration of 40 mM; Sigma, G4505), and 7 mL of the inactivated sample. For calibration, reactions were performed with or without proteinase K and/or guanidine hydrochloride. The reaction was then incubated for 30-40 min at 65 C. The proteinase K inactivation and reaction steps were performed in a closed-lid heating block or, for proof of concept, in a Thermos cup, using warm water. In the case of the Thermos cup, temperature was monitored using a simple thermometer. After 20 min of incubation, aliquots were monitored for color change every 5 min using the naked eye, until 40 min of incubation. Samples were considered negative if the original pink color of the phenol red was maintained and positive if the phenol red color turned orange yellow. Test results were interpreted without prior knowledge of the reference standard results. True positive rate (TPR), true positive rate (TNR), true negative rate (FPR), false positive rate (FNR), and false negative rate (FNR) values were calculated according to the following equations: We first performed RT-LAMP on RNA purified from COVID-19-positive and -negative swabs, with the set of ........................................................................................................................................................ .... primers described by Zhang et al. 4 As reported by Zhang et al., 4 our RT-LAMP results agreed with those obtained using standard RT-qPCR (Figure 1(b) ). To simplify the detection method, we next conducted RT-LAMP on clinical diagnostic throat and nose swabs collected from patients and maintained in UTM. After inactivating the samples by heating the UTM to 95 C for 5 min, the inactivated samples from confirmed patients were deemed as positive by the RT-LAMP reaction (Figure 1(c) ). We then evaluated this RT-LAMP protocol on a cohort of 99 patients that were previously tested in hospital labs by the standard RT-qPCR method. The tested pool included 27 positive samples containing a wide range of viral load and 72 negative samples. The detection limit of the RT-LAMP protocol was at an RT-qPCR cycle threshold (Ct) of 27.8 (Figure 1 Table 1) . Although no FPs were noted, the number of TPs was very low. Hence, we looked to improve the RT-LAMP protocol for detection from clinical diagnostic patient swabs. Since these swab samples may contain enzymatic inhibitors that could affect the efficiency of viral RNA detection, the impacts of adding proteinase K and guanidine hydrochloride to the process were tested. Proteinase K was added to UTM samples, while guanidine hydrochloride was introduced at the RT-LAMP reaction step. We compared the two protocols on samples from eight patients presenting low, medium, and high Ct values. Of seven patients deemed positive by RT-qPCR (Ct < 37), two were clearly RT-LAMP-positive according to the former protocol, while two additional ones (i.e. a total of four) were identified as positive using the modified protocol. We concluded that the adjustments made improved the efficiency of the RT-LAMP protocol to directly detect viral RNA in clinical diagnostic swab samples (Figure 1(f)) . Lastly, we also tested samples from patients confirmed as infected with viruses other than SARS-CoV-2, including Herpes simplex virus (HSV), respiratory syncytial virus (RSV), influenza and enterovirus. As shown in Figure 1 (g), our RT-LAMP protocol deemed these individuals as negative, and only the sample containing SARS-CoV-2 RNA has tested positive. With this adjusted protocol, we next tested its validity on a cohort of 83 patients suspected of being infected with SARS-CoV-2. These patients were tested at RHCC using the standard RT-qPCR method, 31 were deemed negative and 52 were recognized as positive, presenting a wide range of RT-qPCR Ct values (14-35). To determine the optimal incubation time needed to yield the highest number of true positives without increasing the rate of false negatives, we performed RT-LAMP for up to 40 min and evaluated the colorimetric results obtained at the 30, 35, and 40-min time points. We thus found that the number of TPs increased, while the number of FNs decreased over time. No change in the number of TNs was noted, and only one FP was reported throughout (Figure 2 Table 2 ). Hence, in the conditions employed, it was concluded that incubation times of 35 and 40 min were optimal. Results obtained after a 40-min incubation are provided in Figure 2 (c). When these results were compared to RT-qPCR Ct values obtained from the same patient samples, it was determined that RT-LAMP was most sensitive in terms of detecting positive patients with viral loads that corresponds to low and medium Applying RT-LAMP protocol on saliva samples from confirmed patients Human to human transmission of SARS-CoV-2 is mainly mediated by saliva droplets. 10 Comparing saliva samples to the standard swabs revealed the presence of higher viral loads in saliva. 11 Indeed, the FDA has recently approved saliva as a source for detecting COVID-19 (https://www. fda.gov/media/136875/download). Therefore, we next performed RT-LAMP on human saliva samples selfcollected from three different COVID-19-confirmed patients and one suspected negative subject. In parallel, we also performed the standard RNA purification and RT-qPCR reactions on the saliva samples in a hospital setting. Testing saliva samples from the confirmed patients by both RT-LAMP and RT-qPCR confirmed the positive assessments, whereas the suspected negative subject was confirmed as being negative (Figure 3(a) ). As a positive control for the reaction and saliva sampling, we tested for the human pop7 gene in addition to SARS-CoV-2 gene N. Indeed, pop7 was detected in all saliva samples (Figure 3(a) ). RT-LAMP is a rapid and simple method to detect purified SARS-CoV-2 RNA. 4 In this study, we addressed the potential of RT-LAMP as a method for the direct detection of the virus in suspected COVID-19 patients. Accordingly, we modified and validated the RT-LAMP protocol for direct SARS-CoV-2 detection from clinical diagnostic patient swab samples. Our experiments were performed in parallel to the standard RT-qPCR, hospital routine method. We thus compared RT-qPCR Ct values to RT-LAMP results from over 180 different patient samples. Upon calibration, our direct RT-LAMP method successfully detected patients with medium to high viral loads, while yielding very few false positives. In this work, we defined the optimal protocol for immediate off-the-shelf use of RT-LAMP in testing putative COVID-19 patients. Most importantly, our protocol does not include an RNA purification step. In fact, other than a constant heat source (e.g. a thermal mug), no sophisticated equipment is required in this approach. The protocol duration is about an hour from sampling to detection, calls for only few reagents, and can potentially be performed by non-professionals or even self-performed (Figure 3(b) ). These features allow for the implementation of our method around the globe, including rural areas. Here we focused on clinical swabs and a few selfcollected saliva samples. To further encourage use of RT-LAMP as a method for identifying COVID-19 patients, we suggest testing this protocol on a larger cohort of human saliva samples. Upon such further validation, this method of SARS-CoV-2 detection can be employed as a surveillance tool for sampling large populations. Indeed, the simplicity of this method, the ready availability of products and its low cost, together will make it easy to continuously monitor suspected infected individuals. This method can, moreover, be used in numerous settings, including medical clinics, nursing homes, the workplace, and at points of entry. Finally, and no less important, this method can easily be adjusted to test for infection by other pathogens. Evaluation of nine commercial SARS-CoV-2 immunoassays The laboratory diagnosis of COVID-19 infection: current issues and challenges Direct RT-qPCR detection of SARS-CoV-2 RNA from patient nasopharyngeal swabs without an RNA extraction step Rapid molecular detection of SARS-CoV-2 (COVID-19) virus RNA using colorimetric LAMP Loop-mediated isothermal amplification of DNA Rapid and sensitive detection of zika virus by reverse transcription loop-mediated isothermal amplification Rapid detection of COVID-19 coronavirus using a reverse transcriptional Loop-Mediated isothermal amplification (RT-LAMP) diagnostic platform Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes A multiplexed RT-LAMP assay for detection of group M HIV-1 in plasma or whole blood Droplets and aerosols in the transmission of SARS-CoV-2 Posterior oropharyngeal saliva for the detection of SARS-CoV-2 SARS-CoV-2 detection for surveillance 1193 We thank the Geva-Zatorsky lab for fruitful discussions and contributions, and the virology team at RAMBAM hospital for hosting us. We would also like to thank Dr. Rich Roberts and Dr. Nathan Tanner for their valuable support, as well as Prof. Yehuda Chowers, Dr. Ronit Almog, Dr. Yuval Geffen, Dr. Dani Zvi-Bar and Prof. Oded Lewinson for their help. The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article. While performing this research, no company had invested in the research, and no commercialization was intended. The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This work was supported by the Technion Integrated Cancer Center, the Technion-Israel Institute of Technology, "Keren Hanasi", the Alon and Horev (Taub foundation) fellowships. HH was supported by A Leonard and Diane Sherman Interdisciplinary Graduate School Fellowship. NGZ is an Azrieli Global Scholar at the Canadian Institute for Advanced Research (CIFAR). This study was granted exemption from the Institutional Review Board (IRB) approval of the Rambam Health Care Campus for the use of deidentified COVID-19 tests performed for the purpose of the standard testing, and for 4 volunteers. Peter Rogov https://orcid.org/0000-0002-1578-7251 Naama Geva-Zatorsky https://orcid.org/0000-0002-7303-854X Supplemental material for this article is available online.