key: cord-0786744-4yfvspaq authors: Ruetalo, Natalia; Businger, Ramona; Schindler, Michael title: Rapid and efficient inactivation of surface dried SARS-CoV-2 by UV-C irradiation date: 2020-09-22 journal: bioRxiv DOI: 10.1101/2020.09.22.308098 sha: d045f9372721472d95c1973c0d5a3784c8b06cf8 doc_id: 786744 cord_uid: 4yfvspaq The SARS-CoV-2 pandemic urges for cheap, reliable and rapid technologies for disinfection and decontamination. We here evaluated the efficiency of UV-C irradiation to inactivate surface dried SARS-CoV-2. Drying for two hours did not have a major impact on the infectivity of SARS-CoV-2, indicating that exhaled virus in droplets or aerosols stays infectious on surfaces at least for a certain amount of time. Strikingly, short exposure of high titer surface dried virus (3*10^6 IU/ml) with UV-C light (0.66 mJ/cm2) resulted in a total reduction of SARS-CoV-2 infectivity. Together, our results demonstrate that SARS-CoV-2 is rapidly inactivated by relatively low doses of UV-C irradiation. Hence, UV-C treatment is an effective non-chemical possibility to decontaminate surfaces from high-titer infectious SARS-CoV-2. Introduction 57 SARS-CoV-2 has spread globally and there is an urgent need for rapid, highly efficient, 58 environmentally friendly, and non-chemical disinfection procedures. Application of UV-C light 59 is an established technology for decontamination of surfaces and aerosols (1-3). This 60 procedure has proven effective to inactivate SARS-CoV-1 (4-6), several other enveloped and 61 non-enveloped viruses as well as bacteria (7). Recently, it has also been shown that SARS-62 CoV-2 is sensitive to inactivation by UV-C irradiation (8-10). However, doses and exposure 63 times necessary for total inactivation of SARS-CoV-2 were in a range precluding efficient 64 application of UV-based methods to be employed for large-scale decontamination of surfaces 65 and aerosols (10). We hence conducted a "real-life" application approach simulating the 66 inactivation of dried surface residing infectious SARS-CoV-2 by a mobile handheld UV-C 67 emitting device and an UV-C box designed to decontaminate medium-size objects. Our data 68 shows that surface dried SARS-CoV-2 retains infectivity for at least two hours. Short 69 exposure of high-titer surface dried SARS-CoV-2 to UV-C light lead to a total reduction of 70 infectivity. Hence, UV-C irradiation is a rapid and cost-effective technology to decontaminate 71 surfaces from high-titer SARS-CoV-2. 72 73 Cell culture. Caco-2 (Human Colorectal adenocarcinoma) cells were cultured at 37 °C with 75 5% CO 2 in DMEM containing 10% FCS, with 2 mM l-glutamine, 100 μg/ml penicillin-76 streptomycin and 1% NEAA. 77 Viruses. The recombinant SCoV2 expressing mNeonGreen (icSARS-CoV-2-mNG) (11) units (IU) of icSARS-CoV-2-mNG were spotted (in triplicates) in 6-well plates and dried for 87 two hours at RT. 6-well plates spotted with dried virus were treated with UV-C-light using the 88 Soluva® pro UV Disinfection Chamber (Heraeus) for 60 seconds or the Soluva® pro UV 89 Disinfection Handheld (Heraeus) for 2 seconds in a fix regime at 5 and 20 cm plate distance. 90 In addition, a moving regime using a slow (3.75 cm/s) and fast (12 cm/s) speed at 20 cm 91 distance was tested. As control, 6-well plates were spotted with the virus and dried, but not 92 UV-treated. After UV-treatment, the spotted virus was reconstituted using 1 mL of infection 93 media (culture media with 5% FCS). As control, 35 uL of the original virus stock were diluted 94 to 1 ml with infection media and used as virus stock infection control. We set up an experimental approach to evaluate the effect of UV-C treatment on the stability 112 5 of SARS-CoV-2. Simulating the situation that exhaled droplets or aerosols from infected 113 individuals contaminate surfaces, we produced a high-titer SARS-CoV-2 infectious stock and 114 dried 35µL of this stock corresponding to ~4*10^6 IU/ml in each well of a 6-well plate. The 115 plates were then either non-treated or exposed to five UV-C regimens (Fig. 1a) . These 116 include inactivation for 60 s in a box designed to disinfect medium-size objects, 2 s exposure 117 at 5 cm or 20 cm distance with a handheld UV-C disinfection device and finally an approach 118 simulating decontamination of surfaces via the handheld UV-C device. For this, we performed 119 slow and fast-moving at a distance of ~20 cm, with "slow" corresponding to a speed of ~3.75 120 cm/s (supplemental movie 1) and "fast" at ~12 cm/s (supplemental movie 2). UV-C irradiance 121 (254 nm) in the box with an exposure time of 60 seconds corresponds to an irradiation dose 122 of 800 mJ/cm²; for the handheld (HH) at 5 cm the UV-C dose at two second irradiation time is 123 80 mJ/cm² and at 20 cm is 16 mJ/cm². From the speed of the "slow" and "fast" moving 124 regimens we calculate a UV-C dose of 2.13 mJ/cm² (slow) and 0.66 mJ/cm² (fast). 125 Subsequently, dried virus was reconstituted with 1 mL infection media and used to inoculate 126 naïve Caco-2 cells at serial dilutions to calculate viral titers. Taking advantage of an infectious 127 SARS-CoV-2 strain expressing the chromophore mNeonGreen (11), we quantified infected 128 (mNG+) and total (Hoechst+) cells by single-cell counting with an imaging multiplate reader. 129 Of note, even short UV-C treatment of the dried virus in the context of the moving "fast" 130 regimen completely inactivated SARS-CoV-2, as no infected cells were detected based on 131 fluorescence protein expression (Fig. 1b) . Titration of two-fold series dilutions of the UV-132 treated and non-treated control samples, as well as the freshly thawed strain as reference, 133 revealed that (i) drying for two hours does not have a major impact on the infectivity of SARS-134 CoV-2 and (ii) all five UV-C treatment regimens effectively inactivate SARS-CoV-2 (Fig. 1c) . 135 Calculation of viral titers based on the titration of the reconstituted virus stocks revealed a 136 loss of titer due to drying from ~4*10^6 to ~3*10^6 IU/ml and effective 6-log titer reduction of 137 SARS-CoV-2 by all employed UV-C treatment regimens (Fig. 1d) . Altogether, our data 138 demonstrate that UV-C regimens that expose high-titer SARS-CoV-2 to doses down to 0.66 139 mJ/cm² are sufficient to achieve complete inactivation of the virus. 140 Disinfection of surfaces and aerosols by UV-C irradiation is an established, safe and non-142 chemical procedure used for the environmental control of pathogens (1-3, 12) . UV-C 143 treatment has proven effective against several viruses including SARS-CoV-1 (4-6) and other 144 coronaviruses i.e. Canine coronaviruses (13). Hence, as recently demonstrated by others (8-145 10) and now confirmed by our study it was expected that SARS-CoV-2 is permissive for 146 inactivation by UV-C treatment. One critical question is the suitability of this technology in a 147 "real-life" setting in which the exposure time of surfaces or aerosols should be kept as short 148 as possible to allow for a realistic application, for example in rooms that need to be used 149 frequently as operating rooms or lecture halls. Furthermore, in such a setting, we assume that 150 the virus is exhaled from an infected person by droplets and aerosols, dries on surfaces and 151 hence represents a threat to non-infected individuals. We simulated such a situation and first 152 evaluated if surface dried SARS-CoV-2 is infectious. Drying for two hours, in agreement with 153 previous work (14), did not result in a significant reduction of viral infectivity indicating smear-154 infections could indeed play a role in the transmission of SARS-CoV-2 (Fig. 1) . On the other 155 hand, our virus-preparations are dried in cell culture pH-buffered medium containing FCS, 156 which might stabilize viral particles. Hence, even though this is not the scope of the current 157 study, it will be interesting to evaluate if longer drying or virus-preparations in PBS affect the 158 environmental stability of SARS-CoV-2. Irrespective of the latter, UV-C-exposure of dried 159 high-titer SARS-CoV-2 preparations containing ~3*10^6 IU/ml resulted in a complete 160 reduction of viral infectivity (Fig. 1) . In this context, it is noteworthy that we achieved a 6-log 161 virus-titer reduction in a setting simulating surface disinfection with a moving handheld device. 162 With the "fast"-moving protocol (see supplemental video 1) we were exposing surfaces at a 163 distance of 20 cm with a speed of 12.5 cm/s resulting in a calculated UV-C dose of 0.66 164 mJ/cm² at 254 nm. This is substantially less than the previously reported 1048 mJ/cm² 165 necessary to achieve a 6-log reduction in virus titers when exposing aqueous SARS-CoV-2 to 166 UV-C (10). In another study, using a 222 nm UV-LED source, 3 mJ/cm² lead to a 4-log 167 reduction of infectious SARS-CoV-2 (9) and 20 s deep-ultraviolet treatment at 280 nm 7 corresponding to a dose of 75 mJ/cm² reduced 3-logs (8). 169 Comparing these values to other pathogens, SARS-CoV-2 seems particularly sensitive 170 towards UV-C light. To achieve a 3-log titer reduction, 75-130 mJ/cm² are necessary for 171 adenovirus, 11-28 mJ/cm² for poliovirus, and bacteria as for instance Bacillus subtilis require 172 18-61 mJ/cm² (7). This is in-line with susceptibility of SARS-CoV towards UV-C in aerosols at 173 2.6 mJ/cm², whereas adenovirus or MS2-bacteriophages were resistant to such a treatment 174 (1). 175 Altogether, we establish the effectiveness of UV-C treatment against SARS-CoV-2 in a 176 setting designed to simulate realistic conditions of decontamination. The easy, rapid, 177 chemical-free, and high efficacy of UV-C treatment to inactivate SARS-CoV-2 demonstrates 178 the applicability of this technology in a broad range of possible settings. Effect of ultraviolet germicidal irradiation on viral aerosols. Environ 198 Sci Technol Role of ultraviolet (UV) disinfection in infection control and 200 environmental cleaning Role of Ultraviolet Disinfection in 202 the Prevention of Surgical Site Infections Stability of SARS 204 coronavirus in human specimens and environment and its sensitivity to heating and UV 205 irradiation Large-scale preparation of UV-inactivated SARS coronavirus 207 virions for vaccine antigen Inactivation of the coronavirus 209 that induces severe acute respiratory syndrome, SARS-CoV UV Dose) Achieve Incremental Log Inactivation of Bacteria, Protozoa, Viruses and Algae Rapid inactivation of 215 SARS-CoV-2 with deep-UV LED irradiation 217 Effectiveness of 222-nm ultraviolet light on disinfecting SARS-CoV-2 surface contamination 220 Susceptibility of SARS-CoV-2 to UV irradiation An 222 Infectious cDNA Clone of SARS-CoV-2 No touch' technologies for environmental 224 decontamination: focus on ultraviolet devices and hydrogen peroxide systems Williamson 229 BN, et al. Aerosol and Surface Stability of SARS-CoV-2 as Compared