key: cord-0786028-27oagob6 authors: Hudziak, Damian; Wańha, Wojciech; Gocoł, Radosław; Parma, Radosław; Ochała, Andrzej; Smolka, Grzegorz; Ciosek, Joanna; Darocha, Tomasz; Deja, Marek A.; Wojakowski, Wojciech title: Short-term safety and efficacy of transcarotid transcatheter aortic valve implantation with balloon-expandable vs. self-expandable valves date: 2021-03-27 journal: Postepy Kardiol Interwencyjnej DOI: 10.5114/aic.2021.104772 sha: 383e72b88ca0773b1f41abd942cefe9ca858f6a4 doc_id: 786028 cord_uid: 27oagob6 INTRODUCTION: Transfemoral access (TF) is the preferred access for transcatheter aortic valve implantation (TAVI). Transcarotid TAVI (TC-TAVI) is an alternative for patients in whom TF-TAVI is impossible. Two types of valves – balloon-expandable (BE) and self-expandable (SE) – can be used in TC-TAVI procedures. AIM: Comparison of the short-term results of patients treated with TC-TAVI using BE and SE valves. MATERIAL AND METHODS: The retrospective registry included 39 patients in whom the TC-TAVI procedure was performed between 2017 and 2020 (BE-TAVI; n = 10, SE-TAVI; n = 29). Preoperative characteristics, operative and postoperative results, and 30-days mortality were compared. RESULTS: Patients from the BE-TAVI group had higher surgical risk (EuroSCORE) (10.8% (6.2–14.0) vs. 5.5% (4.3–8.7); p = 0.027). The incidence of chronic obstructive pulmonary disease (COPD) was higher in the SE-TAVI group (34.5% vs. 0%; p = 0.040). In terms of other comorbidities, demographics, preprocedural laboratory results, transthoracic echocardiography (TTE), and multislice computed tomography (MSCT), the two groups were comparable. In both groups, we observed 100% procedural success. The median valve size was larger in the SE-TAVI group (29.0 (26.0–29.0) vs. 26.0 (23.0–26.0); p < 0.001). The hospitalization time was shorter in the BE-TAVI group vs. SE-TAVI (5.8 ±0.6 vs. 6.4 ±0.9; p = 0.043). We did not observe statistically significant differences between BE-TAVI and SE-TAVI in periprocedural and 30-day mortality, or the number of strokes/TIA. Also TTE parameters and NYHA class showed similar improvement at 30 days in both groups. CONCLUSIONS: TC-TAVI using balloon-expandable and self-expandable valves showed similar safety and efficacy in 30 days follow-up. Transcatheter aortic valve implantation (TAVI) has become a standard of care for patients with severe symp-tomatic aortic stenosis (AS) who are not eligible for conventional surgical aortic valve replacement (SAVR) and have high surgical risk. Also, based on the heart team decision it is an accepted treatment for intermediate and low-risk patients with additional factors favoring the non-surgical approach [1] [2] [3] . The transfemoral (TF) access is preferred in all patients because it has the lowest complication rate [4, 5] . However, in 15-20% of TAVI patients TF is impossible due to concomitant peripheral arterial diseases (PAD) and abnormalities of the thoracic and abdominal aorta, increasing the risk of bleeding and vascular complications [6] [7] [8] . Since the first TAVI via the left common carotid artery (CCA) described by Modine et al. in 2010 [9] transcarotid (TC) access has been used as an alternative for patients disqualified from TF-TAVI [10, 11] . Both balloon-expandable (BE) and self-expandable (SE) valves can be implanted through the CCA; however, no direct comparisons have been published [10] [11] [12] . The purpose of our registry including all consecutive patients treated with TC-TAVI using BE and SE valves in a large academic institution was to evaluate early safety and efficacy of the procedure depending on the type of implanted valve. The study group consisted of patients with severe symptomatic aortic stenosis who underwent the TC-TAVI procedure in our hospital between 2017 and 2020. Since we aimed to investigate outcomes in the TC-TAVI procedure, patients with only balloon aortic valvuloplasty were excluded from the final analysis. All patients signed written informed consent to the pro-posed treatment. Because of the retrospective study design, no institutional review board permission was required. The results were defined and presented according to the Valve Academic Research Consortium-2 (VARC-2) consensus [13] . The decision on qualification for the TC-TAVI procedure and selection of the size and type of implanted valve prosthesis, BE or SE, was made by the multidisciplinary Heart Team. The access and sizing were planned based on the multislice computed tomography (MSCT) results of the peripheral arteries and aorta, coronary angiography, and transthoracic echocardiography (TTE). MSCT analysis was performed using the 3Mensio (Pie Medical Imaging, The Netherlands) software. The presence of thoracic and abdominal aorta disease (aneurysm, thrombus, chronic dissection, history of a stent graft, tortuosity) as well as peripheral artery disease (PAD), small diameter (< 6 mm), severe calcifications and severe angulation of the iliofemoral arteries disqualified the patient from the femoral access. The MSCT analysis method for carotid access and the operating technique has been described in detail in the previous article [14] . Patients who had CCA diameter more than 5.5 mm and no significant stenosis (> 50%), excessive angulation, and calcifications were qualified for TC-TAVI. All procedures were performed in the hybrid operating room during general or local anesthesia by the multidisciplinary TAVI team. Every patient received a pre-procedural intravenous dose of antibiotic (1.5 g cephazolin) to prevent infective endocarditis. Heparin was given in a dose of 100 U/kg (activated clotting time > 250 s). After placement of two 5-0 monofilament continuous purse-string sutures, the 6-Fr vascular sheath was inserted into the carotid artery. The pigtail catheter was positioned in the noncoronary sinus using a 6-Fr sheath inserted through the radial or femoral artery. An endocavitary electrode for rapid ventricular pacing was introduced into the right ventricle through the femoral or jugular vein. Intraoperative monitoring of each patient included regional cerebral oximetry (Covidien, Medtronic plc, Ireland), arterial blood pressure, central venous pressure, saturation of arterial blood, electrocardiography, and transthoracic (TTE) or transoesophageal echocardiography (TOE). Selective carotid angiography was performed to assess arterial patency after the removal of the delivery system. Categorical data were presented as numbers (%). The Kolmogorov-Smirnov test was used to assess the data distribution. Normally distributed values were presented as mean with standard deviation. Non-normally distributed values were presented as median with 25 th and 75 th percentile (interquartile range (IQR)). Continuous data were compared by Student's t-test or by the Mann-Whitney U test, depending on the distribution. Forty patients were qualified for the TC-TAVI procedure from September 2017 to October 2020 in the Upper Silesian Medical Center of the Medical University of Silesia in Katowice, Poland. One patient was exclud-ed from the analysis because he died intraoperatively prior to aortic valve implantation. The cause of death was a rupture of the aortic annulus during predilation. The retrospective study finally enrolled 39 patients (10 (25.6%) BE-TAVI and 29 (74.4%) SE-TAVI) ( Figure 1 ). The baseline characteristics of the patients are included in Table I . The groups did not differ in age (74.5 (69-81) vs. 77 (72-84.2); p = 0.349) or gender (80% males vs. 44.8%; p = 0.073). All patients were symptomatic with baseline NYHA class ≥ III. Patients in SE-TAVI had a higher inci- Table III . 100% device success was observed in both groups. There were no procedural deaths in patients in whom the valve was implanted. All of BE-TAVI and 93.1% of SE-TAVI were performed under general anesthesia (p = 1.000). Coronary occlusion, prosthetic dislocations and dysfunction which required conversion to SAVR were not observed in either group. There was a similar number of other events defined by VARC-2: myocardial infarction, major vascular complication, life-threatening bleeding, and acute renal failure in BE and SE groups (Table III). Most of the procedures were performed through the LCCA and a minority through the RCCA (9/10 BE and 28/29 SE). The procedural time, as well as the percentage of balloon aortic pre-and postdilatation (10% vs. 6.9%; p = 1.000 and 10% vs. 20.7%; p = 0.652 respectively), was not significantly different between the groups. A low rate of neurological complications was observed in both the BE-TAVI and SE-TAVI group (no strokes and only 1 TIA (10%) vs. 2 (6.9%); p = 0.753, respectively) ( Table III) . These data confirm cerebral oximetry results bilaterally during the procedure (Table IV, Figure 1) . The time patients spent in the ICU was similar, while the total hospitalization time was shorter in the BE-TAVI group (5.8 ±0.6 days vs. 6.4 ±0.9 days; p = 0.043). There was no statistically significant difference in the percentage of atrial fibrillation (0% vs. 6.9%; p = 1.000) or pacemaker implantation (10% vs. 13.8%; p = 1.000). Comparison of the postoperative echocardiography parameters (EF, PG max, PG mean) and the NYHA functional class showed no significant differences between the groups. (Table II) The type of the valve prosthesis did not affect 30-day mortality (0 (0%) vs. 2 (6.9%); p = 1.000, respectively) in the BE and SE group. One patient died of an unknown cause 2 weeks after discharge, while the second died 3 weeks after discharge from the hospital due to complications after COVID-19 infection. TAVI through the femoral artery is the preferred access most often used due to the safety [15] . Despite the reduction of the size of access sheaths and the modification of the vascular closure devices (Proglide, Manta), not all patients can undergo TF-TAVI and need alternative access sites. In many centers, TC access has become the first choice for patients for whom the femoral approach is not available. In our hospital, the TC-TAVI percentage is approximately 10% of all TAVI procedures, and it is similar to the result reported by other authors [16, 17] . The common carotid artery is easy to access because of its superficial location and size. The carotid artery preparation technique is not complicated but requires special attention to protect the jugular vein, the vagus, and the laryngeal nerves. The most common local access complications are injury to the vagus nerve, local hematoma, and wound infection [18] . In our group, of these complications, we observed only local hematoma in 1 patient in the BE group. Cerebrovascular events re- lated to the use of the CCA approach, including stroke and TIA, are estimated at 2-4% [11, 19, 20] . In our registry, there was no stroke, and we observed 3 cases of TIA (7.7% in 39 patients), which were not related to the type of prosthesis and resolved within 4 h. We believe that the two aspects are very important in preventing severe neurological complications. The first is a detailed analysis of the MSCT during qualification, allowing one to choose an artery with a larger diameter, less calcification, and tortuosity, and with a more favorable spatial relationship between the virtual CCA centerline and the plane of the aortic annulus. It has a significant impact on facilitating and shortening the time of the procedure. Confirmation in the MSCT of the borderline dimensions of CCA allows one to consider using a sheathless technique for the planned SE valve. The second aspect is the continuous monitoring of cerebral oximetry throughout the procedure, which allows for a quick response to possible brain perfusion disorders. In a meta-analysis of Wee et al. [19] (3.8% neurological complication rate in 364 patients) cerebral oximetry was the main tool for periprocedural cerebral monitoring. Our analysis did not reveal any differences between groups in left and right side cerebral oximetry values in the successive steps of the procedure (Table IV ). In addition, in the comparison of oximetry results for all TC-TAVI, the baseline values did not differ from the values after implantation (Figure 2 ). In our center, during the TC-TAVI procedure, we do not perform a 2-3 min clamping of the carotid artery to check for the Willis circle function, as proposed by some operators [10, 12] . In our surgical technique, the carotid artery was carefully dissected, especially protecting the vagus nerve, and manually examined after dissection for the presence of calcifications. Two 5-0 monofilament continuous purse-string sutures were used similarly to the technique used to cannulate the ascending aorta during the classical surgical operation. After the procedure, the carotid artery was closed using sutures without clamping. We do not prefer clamping the carotid artery to reduce its trauma. In cerebral oximetry, we did not observe a difference in saturation between the left and right sides after leading the delivery sheath (14, 16 Fr) (oximetry values were not lower than 55%); this allowed the procedure to be continued safely. In our observation, valve selection had no effect on the other endpoints according to the VARC-2 consensus. Percentages of life-threatening bleeding (2.6%), myocardial infarctions (2.6%), major vascular complications (2.6%), acute kidney injuries (0%), pacemaker implantations (12.8%), and all mortality (6.9%) for all the TC-TAVI group were comparable with the results reported by other authors. Similar results were obtained for the choice of implantation site (LCCA-94.9% (90% in the BE group and 96.6% in the SE group)) and type of anesthesia (general anesthesia -94.9% of all TC-TAVI (100% in the BE group and 93.1% in the SE group)) [11, 16, 17, 19] . We prefer general anesthesia with intubation because this method increases security by reducing the uncontrolled movement of the patient. However, in special situations, we successfully performed TC-TAVI using SE valves in 2 patients. The results of large analyses comparing the implantation of two types of valves (BE vs. SE) implanted transfemorally are inconclusive. In the French registry comparing the results of the Sapien 3 BE valve with the Evolut R SE valve, 20,918 patients showed lower numbers of all-cause death, cardiovascular death, rehospitalization for heart failure, and pacemaker implantation in the group of patients with a Sapien 3 BE valve [21] . On the other hand, Vlastra et al., analyzing 12 381 patients, did not confirm lower 30-day mortality in the BE valve group. They found lower incidence of strokes and pacemaker implantation but more life-threatening bleeding events in these groups [22] . In our analysis, all perioperative and postoperative outcomes in the study groups were comparable. Independent of valve prosthesis type, significant reduction of NYHA class, and improvement of echocardiographic parameters (Pg max, Pg mean, Vmax, and low number of severe (> 2 grade) paravalvular leaks (PVL)) were observed. These data confirmed the good hemodynamic profile of the used prostheses, as well as the adequate size and correct implantation. Paravalvular leak, structural valve deterioration, prosthesis-patient mismatch, leaflet thrombosis, and endocarditis can lead to faster valve dysfunction [23] . Morphometric analysis of aortic valve calcifications in MSCT described by Ryś et al. seems to be an interesting method to reduce the potential risk of PVL in TAVI procedures [24] . The choice between an SE or BE valvular prosthesis depends mainly on the analysis of MSCT (values of the aortic valve annulus area and annulus perimeter, height of the left and right coronary artery, and diameter of the common carotid arteries), type of the native valve (tricuspid vs. bi-cuspid), presence of the failed aortic bioprosthetic valve (ViV) and extent of calcifications (especially massive calcifications extending into the left ventricular outflow tract). In addition, in our opinion, in patients who have a smaller size of the common carotid arteries, it is worth using a self-expanding valve because it can be implanted without a dedicated vascular sheath. This may be important for blood flow through the carotid artery and the reduction of neurological complications. In patients with a higher EuroSCORE, we prefer to use BE valve prosthesis implantation because, in our opinion, this system is more predictable, avoids pre-and post-dilatation, and the procedure time is shorter, which may be important for the course and safety of the procedure. The presented analysis has several limitations. The study was retrospective, non-randomized, and single-center. Only the early results were assessed. Patients in the BE valve group had a higher EuroSCORE II risk. On the other hand, all of the TC procedures were performed consistently according to the institutional standard operating procedures. Importantly, the TC TAVI was always done under brain oxygenation monitoring. Based on our registry, we can conclude that transcarotid access is safe and effective, independently of which types of valve prosthesis (balloon-expandable or self-expandable) were used. In our opinion, precise preprocedural multivariate analysis of MSCT and continuous monitoring of cerebral oximetry are key to the success of transcarotid TAVI. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis. First Human Case Description Transcatheter aortic-valve implantation for aortic stenosis in patient who cannot undergo surgery Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of severe aortic stenosis: a meta-analysis of randomized trials ESC Scientific Document Group. 2017 ESC/EACTS guidelines for the management of valvular heart disease AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines predictors, and implications of access site complications with transfemoral transcatheter aortic valve implantation 2016 annual report of the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry Temporal trends in transcatheter aortic valve replacement in France: FRANCE 2 to FRANCE TAVI Aortic valve implantation with the CoreValve ReValving System via left carotid artery access: first case report The carotid artery as a preferred alternative access route for transcatheter aortic valve replacement Transcarotid transcatheter aortic valve replacement: feasibility and safety Transcarotid transcatheter aortic valve replacement: general or local anesthesia Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document Prospective registry on cerebral oximetry-guided transcarotid TAVI in patients with moderate-high risk aortic stenosis Alternate access for TAVI: stay clear of the chest Comparison of transcarotid vs. transfemoral transcatheter aortic valve implantation Carotid versus femoral access for transcatheter aortic valve implantation: a propensity score inverse probability weighting study Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis Transcarotid transcatheter aortic valve implantation: a systematic review Transcarotid compared with other alternative access routes for transcatheter aortic valve replacement Impact of Sapien 3 Balloon-Expandable Versus Evolut R self-expandable transcatheter aortic valve implantation in patients with aortic stenosis: data from a nationwide analysis Comparison of balloon-expandable vs. self-expandable valves in patients undergoing transfemoral transcatheter aortic valve implantation: from the CENTER-collaboration New advances in the prevention of transcatheter aortic valve implantation failure: current and future perspectives Quantitative estimation of aortic valve calcification in multislice computed tomography in predicting the development of paravalvular leaks following transcatheter aortic valve replacement The authors declare no conflict of interest.