key: cord-0784472-d9du0kot authors: Tu, Jing; Qiao, Yi; Luo, Yuhan; Long, Naiyun; Lu, Zuhong title: Quantifying genome DNA during whole-genome amplification via quantitative real-time multiple displacement amplification date: 2021-01-22 journal: RSC advances DOI: 10.1039/d0ra09021b sha: 9234a3ded2cc8ad54a6b8b6d50e16b2470cbad42 doc_id: 784472 cord_uid: d9du0kot DNA quantification is important in the research of life sciences. In an independent quantification process, the extracted part of a DNA sample is usually difficult to be recycled for further use while the widely used real-time PCR is used to count the copies with certain sequences. Based on the popular multiple displacement amplification (MDA), we proposed and performed quantitative real-time MDA to obtain the information of template amount based on fluorescence signals while amplifying whole-genome DNA. The detection limit of real-time MDA was as low as 0.5 pg μl(−1) (5 pg DNA input), offering the whole-genome research a promising tool to quantify the entire DNA during amplification without sacrificing sample completeness or introducing redundant steps. Multiple displacement amplication (MDA) has become one of the most popular whole genome amplication (WGA) methods since it was rst proposed by Dean et al. 1 In MDA, strand displacement DNA polymerase such as phi29 DNA polymerase or Bst DNA polymerase amplies genome DNA under isothermal conditions through the extension of a random hexamer primer. With a much higher coverage breadth and delity than its rivals 2,3 and simplicity in protocol, MDA has been widely used in low initial amount DNA amplifying, particularly in the preparation step for whole genome sequencing 4,5 and forensic analysis. 6 Particularly, MDA has been routinely used in single cell genomic research as the DNA amplifying method, with proven delity in conserving single-cell heterogeneity in the sample preparation step of high-throughput sequencing. 7, 8 However, in most of existing protocols, the initial DNA amount in MDA is obtained additionally before amplication or maintained undetermined all along. Although there are commercial kits that quantify DNA directly by measuring the uorescence and have achieved fairly low detection level (e.g. 25 pg ml À1 in Quant-iT Picogreen, ThermoFisher, US), a large sample amount is required (>50 pg in Quant-iT Picogreen). When dealing with rare and precious samples, the part extracted for quantication is hard to recycle for further use in any downstream sections and that introduces unnecessary waste of sample. Quantication during amplication could avoid sample waste in the quantifying process where the amount of the initial DNA template is calculated through the efficiency of amplication. As a classical quantication strategy, real-time PCR (also known as quantitative PCR, qPCR) 9,10 measures the original concentration of the template through the C t value (dened as the cycle number before the uorescence reaching a certain threshold). 11 Its accuracy and sensitivity in quantication (several copies of the template are enough for the reaction 12 ) make it an extremely common tool in gene expression research 13, 14 and disease diagnosis. 15, 16 In particular, the 2019 novel coronavirus was rst detected by real-time PCR, 17 which is of great signicance. Nonetheless, the primers in qPCR are unique; therefore, only the copy number of specic sequence is counted and the non-target molecules are not taken into account. As a result, PCR-based methods are not suitable for quantifying the total amount of DNA, and cannot be used in the whole-genome research. Some methods based on WGA are realized to quantify trace amounts of DNA with principle similar to qPCR. Kang et al. 18 successfully detected sub-picogram amounts of DNA via DOP-PCR using the SYBR dye, and the digital counting principle was also used in LAMP. 19 In the aspect of MDA, monitoring MDA during amplication is proposed and carried out using a uorescent dye with an initial concentration as low as 5 pg ml À1 , 20 but the detection level and detailed description of the amplifying process can be further investigated. Considering the versatility of MDA, accurate quantication would contribute to the simplicity and certainty of varieties of DNA analyzing processes. Here, we proposed a DNA quantication method based on real-time MDA. The process of the MDA reaction was monitored via obtaining uorescence signal, and the baseline time was measured to predict the initial DNA amount in the solution (Fig. 1) . The inuence Of the dye and threshold setting was also compared to ensure the quality of amplied DNA. A sequential dilution was performed to evaluate the accuracy and detection limit of this method. This real-time MDA method was proven to become a promising DNA quantication tool in the wholegenome research with the detection limit as low as the pictogram (sub-single cell) level. Genomic DNA extracted from the GM12878 cell line was used as the template for real-time MDA, and the amount of template was controlled by adding a diluted DNA solution. The MDA system contained 1Â phi29 DNA polymerase reaction buffer (New England Biolabs, USA), 50 mM random hexamer primer (Sangon, China), 4 mM dNTP, 1.5 U ml À1 phi29 DNA polymerase (New England Biolabs, USA), 0-4Â EVAgreen dye (Biotium, USA) and 1Â ROX dye (Takara, Japan). The reaction was carried out under 30 C and the polymerase was inactivated with 65 C aer amplication using a real time thermal cycler (ABI 7500, Life Technologies, USA). Fluorescence intensity was detected and recorded every 9 min. The threshold was dened in different values, as described in the results section. Plots and tting curves were generated using Origin Pro 2017. Genomic DNA extracted from 3 different tumor cell lines (U937, A375 and ZR-75) was adjusted to 125 pg ml À1 and then diluted to 1/5 sequentially (5 times) with water. The samples of different DNA concentrations were then amplied via real-time MDA. The threshold time was measured and the dilution time was calculated accordingly. Agarose gel electrophoresis was performed to demonstrate the state of DNA samples amplied via quantitative real-time MDA. Amplied samples (3 ml) mixed with the loading buffer (0.6 ml) were loaded into lanes in a 1% agarose gel stained by GelRed (Biotium, USA) and were photographed aer 30 min of electrophoresis. A DL15000 DNA ladder (Takara, Japan) was also added as the length reference. Inuence of the EVAgreen dye on MDA efficiency A real-time MDA protocol was designed to monitor DNA concentration increase through uorescence change during amplication. EVAgreen was chosen as the indicating dye for its higher dynamic range and lower amplifying inhibition [9] compared to SYBR green, which is a traditional dye used in qPCR. To test its inuence on MDA and nd a proper concentration setup, performances of different concentrations of EVAgreen were compared (Fig. 2a) . Keeping other conditions same, the baseline time and saturating plateau of MDA varied with the dye concentration. Agreed with the common knowledge, the dynamic range dropped, whereas the reaction efficiency rose as the amount of dye reduced until the amount of dye was too low to clearly indicate the amplication process (0.25Â). The time before the reaction entering its exponential period was also inuenced by the dye. It is clear that for the dye concentration higher than 1Â, the efficiency of amplication decreased with the increase in dye, indicating that the dye truly inhibited the MDA reaction. MDA with 0.25Â EVAgreen was detected to be less efficient than expectation, and we attribute it to the fact that the dye was too little to indicate the dynamic change in the nucleic acid concentration. The electrophoresis results (Fig. 2b) show that the length peaks of samples are similar (above 15 000 bp), but the distribution of sample length varied. It is clear that the dye inhibited MDA, exhibiting both in the total amount and in the length range of the product. A high dye concentration had signicantly more impact on the product than a low dye concentration. MDA could proceed under 0.5Â EVAgreen with rather high efficiency yet got a dynamic range in uorescence lower than the recommended concentration 1Â. We set 1Â and 0.5Â as the concentrations of the EVAgreen dye in the following experiments aiming at a broad dynamic range and low amplifying inhibition, respectively. Genomic DNA extracted from the GM12878 cell line was dilute and quantied via real-time MDA (1Â EVAgreen). The initial concentration of the template was set to 8192 pg ml À1 and was reduced to one fourth in the neighboring group until reaching the lowest concentration of 0.125 pg ml À1 (Fig. S1 †) . One uorescence curve among each concentration group is shown in Fig. 3a . Interestingly, the curves of MDA with a high initial DNA concentration (no less than 128 pg ml À1 in this case) ended up with slightly low intensity repeatedly (Fig. S1 †) than other groups. We assume that it was because the low magnifying time in those groups hindered the further growth of DNA branches in the MDA reaction, which contributed to the increase in the uorescence. First, we dened 30% of total uorescence increase as the threshold and then measured the reaction time below the threshold. The threshold of 30% ensured that MDA had entered into its exponential period, signicantly surpassing the baseline. Since MDA was isothermal, which was maintained at 30 C and cannot be divided into temperature cycles, amplifying time before the threshold was utilized to describe the amplifying speed instead of the C t value used in qPCR. The time before threshold was inversely proportional to the log DNA initial concentration (Fig. 3b) with a slope of À242.17 in the range of 0.5-128 pg ml À1 . Consequently, the detection limit of real-time MDA was determined to be as low as 0.5 pg ml À1 , and the initial amount of DNA in a sample could be relatively quantied according to the performance of known samples and the tting line (red line in Fig. 3b) . Results of other thresholds are also obtained (Fig. S2 †) . The time threshold increased with a decrease in the initial concentration but still exhibited similar trends. It is worth noting that the conventional method of dening threshold in real-time PCR (i.e. 10 times of the standard deviation of rst several signals) was also suitable for measurement but was difficult in rather high initial concentration (Fig. S3 †) . This was because with a high DNA concentration the uorescence signal may rise immediately aer the initiation, leaving no baseline, as shown in Fig. 3a , for deviation calculation. Moreover, the inhibition of high initial DNA concentration on the nal intensity may also impact the detection limit. While the tted points exhibited a nice predictable trend, some of the data outside the 0.5-128 pg ml À1 range did not. The concentration higher than the range did not follow the inversely proportional trend despite their low deviations because the initial uorescence was so high that it occupied a considerable amount of the total dynamic range of the dye (Fig. 3a) , which made them more suitable for direct quantication. The standard variation of each group increased when the initial DNA concentration went down (orange triangles in Fig. 3b) , suggesting a higher accuracy of quantication in the relatively high initial amount. As a result, the initial concentration of 0.125 pg ml À1 and below was excluded for their low accuracy and high deviation. Based on the slope of the tting line, the efficiency E of MDA in its exponential period could be calculated according to the principle of exponential amplication: The efficiency E of MDA was 1.0% per minute. Alternatively, the amount of DNA in the present MDA reaction doubled every $70 min. Given an initial DNA concentration of 0.5 ng ml À1 , it would take $10 h to reach $200 ng ml À1 , which generally agrees with the common knowledge on the MDA reaction time. Further, under the consideration that dye would inevitably hinder the amplication progress, the actual reaction time would not be longer than the expectation. Aer dilution to 125 pg ml À1 , the concentration of DNA extracted from tumor cell lines was adjusted based on the results quantied via Qubit 2.0 (Table S1 †). The threshold time in the real-time MDA of DNAs was measured (Table S2 †) . The dilution factor of samples was calculated via the formula, as shown in Fig. 3 . The predicted dilution factors showed a strong linear relationship with the actual dilution factors (Fig. 4 and Table S3 †), indicating the reproducibility and generalization of this quantication method. Results of the high dilution factor where the initial DNA concentration was estimated to be $0.2 pg dried rather far from the line, so the application in an extremely low DNA concentration should be concerned with more care. We also tested the performance of quantitative real-time MDA with a 0.5Â EVAgreen dye (Fig. S4 , and S5 †). The lower detection limit was clearly not as low as that with 1Â EVAgreen ($2 pg ml À1 vs. 0.5 pg ml À1 ). The $4 times difference may be attributed to the lower amount of dye that could maintain enough sensitivity even aer hours (>9 h) of stand-by time. However, the tting line of plots within the reliable range still showed a high R-square (0.989 for threshold ¼ 30% total increasing). With the optimized parameters, the detection level of the real-time MDA could be down to 5 pg (0.5 pg ml À1 DNA in 10 ml solution); however, the reaction setting is preferable on amplifying human genome. Care must be taken during quantifying samples from different species since uctuation in the GC content may alter the performance of MDA. 21 In addition, direct uorescent measurement rather than droplet digital MDA (ddMDA) was chosen to quantify DNA because the observed positive fraction was signicantly higher than predicted in ddMDA, which may be contributed by the binary characteristic of the digital analysis and the high sensitivity of MDA. 22 Conclusions MDA has been proven to be a promising tool for whole genome amplication and is wildly used in genome research. In this study, we demonstrated the ability of real-time MDA in quantifying the DNA amount during the whole sequence amplication. Briey, the amplifying time before a certain threshold of real-time MDA exhibits a clear logarithmic trend similar to routinely used qPCR yet entire template molecules was ampli-ed during the quantifying process. The detection limit of realtime MDA could be as low as the picogram (sub-single cell) level. The quantication in this method has low standard variation among a relatively wide range. Based on the results and with proper optimization, real-time MDA should be a powerful quantication tool in whole-genome related researches. There are no conicts to declare. Relationship between predicted and actual dilution factor of various samples