key: cord-0781461-k2s60spi authors: Llandro, H.; Allison, J.; Currie, C.; Edwards, D.; Bowes, C.; Durham, J.; Jakubovics, N.; Rostami, N.; Holliday, R. title: Evaluating aerosol and splatter during orthodontic debonding: implications for the COVID-19 pandemic date: 2020-08-22 journal: nan DOI: 10.1101/2020.08.19.20178319 sha: 4ea0a9336842e597ea9795ed95f254973955e8c4 doc_id: 781461 cord_uid: k2s60spi Introduction: Dental procedures often produce splatter and aerosol which have potential to spread pathogens such as SARS-CoV-2. Mixed guidance exists on the aerosol generating potential of orthodontic procedures. The aim of this study was to evaluate aerosol and/or splatter contamination during an orthodontic debonding procedure. Material and Methods: Fluorescein dye was introduced into the oral cavity of a mannequin. Orthodontic debonding was carried out in triplicate with filter papers placed in the immediate environment. Composite bonding cement was removed using a slow-speed handpiece with dental suction. A positive control condition included a high-speed air-turbine crown preparation. Samples were analysed using digital image analysis and spectrofluorometric analysis. Results: Contamination across the 8-metre experimental rig was 3% of the positive control on spectrofluorometric analysis and 0% on image analysis. There was contamination of the operator, assistant, and mannequin, representing 8%, 25%, and 28% of the positive control spectrofluorometric measurements, respectively. Discussion: Orthodontic debonding produces splatter within the immediate locality of the patient. Widespread aerosol generation was not observed. Conclusions: Orthodontic debonding procedures are low risk for aerosol generation, but localised splatter is likely. This highlights the importance of personal protective equipment for the operator, assistant, and patient. The delivery of orthodontics has changed rapidly over the last few months as a result of the coronavirus disease 2019 (COVID- 19) pandemic. Routine dental services all over the world were required to close. Those which remained open were advised to restrict treatment to urgent or emergency care only, initially through urgent dental care centres, 1 with the overarching message being to avoid aerosol generating procedures (AGPs) wherever possible. 2, 3, 4, 5, 6 Guidance on what constitutes an AGP in dentistry is not clear, and existing documents acknowledge a limited evidence base. 7 This guidance specifically mentions high-speed dental instruments (high-speed air-turbine handpiece and ultrasonic scaler) however, orthodontic procedures are not specifically mentioned. Following the gradual reintroduction of dental services, 8, 9, 10 , 11 significant onus is now placed on the need for appropriate personal protective equipment (PPE) wherever AGPs are carried out. 12, 13, 14 In England, the Office of the Chief Dental Officer published its Standard Operating Procedure (SOP) for the resumption of dental services on the 4 th of June 2020 13 which classified "orthodontic treatment" as a non-AGP. Guidance from a number of organisations contradicts this however, by classifying the use of a slow-speed handpiece during removal of bonded orthodontic appliances (debonding) as an AGP. 15, 16 The British Orthodontic Society (BOS) has advised that if a clinician chooses to use a slow speed handpiece, they should work in a dry field and use high volume evacuation. 17 The study cited by the BOS to support this recommendation showed a reduction in respirable particles of up to 44% when dental suction was used, but this investigation examined dust particles not liquid droplets; 18 it is logical to assume however that suction is likely to have a similar effect on droplets. Several methodologies have been used to evaluate dental aerosol and splatter. These include the use of tracer dyes, 19, 20, 21, 22, 23, 24, 25 measurement of bacterial contamination, 26, 27, 28, 29, 30, 31, 32, 33 and the use of optical particle counting instruments. 34, 35 Various definitions exist for the terms "aerosol" and "splatter". One classification described in the literature defines aerosol droplets as having a diameter of less than 10 µm, 36 with splatter comprising droplets larger than this. Our group has recently developed and described a reliable and valid methodology of evaluating aerosol and splatter created following dental procedures using a tracer dye with digital image and spectrofluorometric analysis. 37 As part of these investigations, we have demonstrated that the use of a 3-in-1 spray (with air and water) produces significant contamination and should be regarded as an AGP, with a 30 second wash causing visual contamination up to one metre. The aim of the present study was to evaluate aerosol and splatter contamination following orthodontic debonding, including removal of composite using a slow speed handpiece with assistant-held dental suction. The methods used in this study have previously been described in detail elsewhere. 37 In summary, an eight-metre diameter rig was used to support grade 1 qualitative cotton-cellulose filter papers (Whatman; Cytiva, MA, USA) spaced at 0.5 m intervals on eight, four metre rods arranged at 45-degree intervals around a dental training mannequin (Model 4820, A-dec; OR, USA). Filter papers were also placed on the forearms, chest, upper leg, and head of the operator and assistant, as well as on their masks and full-face visors. Standard hospital ventilation provided 6.5 air exchanges per hour. 2.65 mM fluorescein solution was used as a tracer and in a modification to our previous work, fluorescein was introduced into the mouth of the mannequin rather than through the water supply to model normal salivary flow. Dental models were soaked in fluorescein for 2 minutes before each experiment, and four, 10 mm diameter cotton rolls were secured to the left and right, upper and lower buccal sulci of the mannequin to replicate a natural reservoir of saliva ( Figure 1 ). Immediately prior to starting the experiment, 5 mL of fluorescein solution was added to the labial surfaces of the teeth, and the cotton rolls. 1 mm internal diameter tubing was secured 5 mm apical to the gingival margins of the upper and lower incisors in the midline, and fluorescein was introduced through the tubing at a rate of 1.5 mL/min for the duration of the experiment to mimic the higher end of the normal stimulated salivary flow range in a healthy adult. 38 Fluorescein was not added to the handpiece irrigation reservoir, and irrigation was not used for the procedure. Figure 1 demonstrates this setup. Prior to the experiment, GAC Ovation® (Dentsply Sirona; PA, USA) orthodontic brackets were bonded from first molar to first molar in both arches on three sets of dental models (Frasaco GmbH; Tettnang, Germany) using Unitek Transbond™ XT Light Cure Adhesive (3M UK PLC; Berkshire, UK). A macro-mechanical lock was created by preparing a 3 mm x 3 mm undercut cross in the labial surface of each tooth using an acrylic bur. This was piloted before the experiment to ensure that after removal of brackets a thin layer of composite remained on the teeth as in vivo. A 0.14 mm nickel-titanium wire was ligated in each arch. During the experiment, the brackets and archwire were removed using orthodontic debonding pliers and the teeth were polished with a fluted tungsten carbide bur in a 1:5 ratio dental handpiece All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 22, 2020. . https://doi.org/10.1101/2020.08.19.20178319 doi: medRxiv preprint driven by an air motor at full speed. Large bore dental suction was operated by an assistant, closely following the operator's handpiece, with a flow rate of 105 L/min of air measured using a commercial dental suction flow meter (RAMVAC FlowCheck, DentalEZ; PA, USA), or 6.3 L/min of water. The procedure lasted for 10 minutes and filter papers were left for 10 minutes after the end of the procedure before collection. The experiment was repeated three times. A positive control condition -high-speed air-turbine crown preparation of the upper right central incisor -was carried out under the same conditions as the orthodontic debonding procedure including assistant-held dental suction. Contamination of the filter papers was assessed as previously described 37 using fluorescence photography with a 500-600 nm wavelength halogen lamp (QHL75 model 503; Dentsply, NC, USA) and DSLR camera (EOS 1000D, Canon; Tokyo; Japan), and subsequent image analysis using ImageJ (v1.48 NIH; MD, USA) to give a surface area measurement (mm 2 ) of fluorescein contamination. Filter papers were also assessed using spectrofluorometric analysis as previously described 37 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 22, 2020. . https://doi.org/10.1101/2020.08.19.20178319 doi: medRxiv preprint For the positive control procedure (high-speed air-turbine crown preparation), aerosol and/or splatter deposition was largely concentrated in the central one metre but with some smaller deposits observed across the experimental rig. Of the 195 samples on the experimental rig (65 samples per run with three independent repeats), image analysis identified 18 contaminated samples, with spectrofluorometric analysis identifying 12 contaminated samples. There was significant operator contamination (total of 54,521 RFU) and much less assistant contamination (total of 2,417 RFU). Combining all the samples and replicates, total contamination for the positive control was 116,482 RFU. Supplemental Table 1 provides a detailed breakdown. The pattern of contamination was similar to previously reported and is shown in Figure 2 See Table 1 for further details. Operator and assistant contamination was observed, with the right leg of the operator being the most contaminated location (3.43 mm 2 ; 3,777 RFU) followed by the right leg of the assistant (contamination on spectrofluorometric analysis 393 RFU). The operator's mask was contaminated on spectrofluorometric analysis only (343 RFU) as was the assistant's visor (208 RFU). The mannequin had contamination on the upper left torso only (4.37 mm 2 ; 4,671 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 22, 2020. . https://doi.org/10.1101/2020.08.19.20178319 doi: medRxiv preprint RFU). Combining all the samples and replicates, total contamination for the orthodontic debonding procedure was 11,307 RFU. Figures 3 and 4 present summarised data by sample location for the two procedures based on analysis technique. The orthodontic debonding procedure produced considerably less contamination across all samples. Across the experimental rig, the orthodontic debonding procedure produced 3% of the contamination of the positive control when comparing the spectrofluorometric analysis data (0% when comparing the image analysis data). Similarly, the operator has 8% (2% on image analysis), assistant 25% (0% on image analysis), mannequin 28% (8% on image analysis). The vast majority of samples showed no contamination across our eight-metre experimental area for the orthodontic debonding procedure. In contrast, our positive control (anterior crown preparation) showed much higher levels of local contamination and some distant contamination. This supports the guidance from the English CDO 13 that an orthodontic debonding procedure using a slow-speed handpiece, in a dry field with high volume suction does not produce a widespread aerosol and is extremely low risk for aerosol generation. The procedure did however produce splatter, which contaminated the patient, operator, and assistant; this is consistent with microbiological studies which have investigated contamination from orthodontic debond in the immediate vicinity of the patient, operator, and assistant. 40 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Our analysis identified a single positive reading at 3.5 m from the orthodontic debonding procedure, which warrants further consideration. This could be a false positive (i.e. accidental contamination), however extensive developmental work and contamination testing was completed to reduce the chance of this, 37 and as a result we set the lower threshold of detection by spectrofluorometry at 164 RFU. The reading at 3.5 m was 1,259 RFU, eight times larger than our lower threshold (164 RFU), which suggests that this reading is unlikely to be spurious. We hypothesise this could be related to the removal of the archwire; a flexible wire was used which may have propelled fluorescein due to spring-back when the wire was removed from the mouth. A flexible wire was used in this study to simulate the use of a flexible finishing wire such as nickel titanium, titanium molybdenum alloy, or braided stainless steel, as spring-back could produce splatter thus modelling a worst-case scenario. Most patients will be in a rigid wire at completion of treatment, which would reduce the risk of splatter from spring-back. If a flexible archwire is used we propose that a barrier such as gauze is placed over the wire prior to its final disconnection and removal from the mouth, in order to mitigate against this risk. Another possible All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 22, 2020. . explanation for this reading is a small volume of "saliva" coming into contact with the bur. This is consistent with our previous work which demonstrated that this region (315°) is high risk for contamination. 37 It is interesting to note that two samples were positive for contamination on image analysis but not on spectrofluorometric analysis. We hypothesise that dry debris may have settled onto these samples, but did not absorb into the filter paper, explaining the presence on photographic analysis but not on spectrometric analysis (suggesting that debris may have fallen off the sample during transfer). This is further supported by the location of these samples being very close to the source (≤ 0.5 m). Knowledge about the infectivity of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is still developing but from our current knowledge of the susceptibility of coronaviruses to desiccation, 41 the risk is likely to be lower from dry debris than droplets; these particles are also likely to be larger and non-airborne. The contamination readings obtained in the present study by using fluorescein in the mouth of the mannequin were significantly lower for the positive control condition (anterior crown preparation with suction) than we have previously reported using fluorescein in the irrigation reservoirs of dental instruments. 37 This is perhaps unsurprising but demonstrates that only a small proportion of the aerosol and splatter produced by dental procedures is likely to be made up of saliva (and/or blood). This All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 22, 2020. . https://doi.org/10.1101/2020.08.19.20178319 doi: medRxiv preprint dilution effect should be the subject of further study but indicates that this model is likely to be more biologically and clinically relevant. The suction used in the present investigation would be typically described as "high flow dental suction" or "high volume evacuation", however on the basis of the flow rate we measured, this would be more correctly classified as "medium volume suction" according to existing standards. 42 Based on our testing (unpublished data) this is within the normal range for this type of suction found in dental settings, and is consistent with previously reported studies. 32 Our methodology has some limitations. The splatter and aerosol detection technique used in this study was a passive technique, in that it relied on contaminated splatter or aerosol naturally settling onto filter papers. Active sampling techniques (such as air samplers or particle counting instruments) are available and would complement this work. These methods too have limitations however, such as the spot nature of their sampling, which would make sampling of the 101 locations used in this investigation impractical. Also, as these methods are non-specific, once particle levels have returned to background levels, it is challenging to know how much of the background sample is made up of source aerosol. Another potential limitation of the present study is the setup of the "salivary ducts" as these were positioned in a nonanatomical position. We chose this position (Figure 1 ) to counteract the fact that the mannequin does not move and has no (un)conscious muscle tone or movement of the lips, tongue, and vestibules to distribute saliva around the mouth. The ducts were therefore positioned anteriorly to attempt to simulate more natural (albeit passive in our model) saliva flow around the mouth. The flow rate of instilled fluorescein (1.5 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 22, 2020. . https://doi.org/10.1101/2020.08.19.20178319 doi: medRxiv preprint mL/min) used was also in the stimulated saliva flow range, which would likely occur when dental treatment was being performed. Our salivary flow model therefore represents a worst-case scenario for saliva contamination. Finally, as we have explored in our previous work 37 there are still many unknowns about SARS-CoV-2 such as the infective dose, and more biologically relevant models are required. Within the limitations of this study, an orthodontic debonding procedure (with a slow speed handpiece, dental suction, and in settings with at least 6.5 air changes per hour) appears to be low risk for aerosol generation but localised splatter is likely. This has implications for operator and assistant PPE (including a disposable apron and mask plus visor) and highlights the importance of patient aprons. The Author(s) declare(s) that there are no conflicts of interest. This study was supported in part by a research grant from the British Endodontic The views expressed are those of the authors and not necessarily those of the NHS, the NIHR or the Department of Health and Social Care. Nadia Rostami was funded All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 22, 2020. . (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 22, 2020. . https://doi.org/10.1101/2020.08.19.20178319 doi: medRxiv preprint Table/Figure Captions Table 1 . Dental aerosol and splatter as measured by contaminated surface area using image analysis or by spectrofluorometric analysis. For each experimental condition, the data from an average of three repetitions for all samples at each location are included together. RFU: relative fluorescence units. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 22, 2020. . https://doi.org/10.1101/2020.08.19.20178319 doi: medRxiv preprint 842-8. 2. Centres for Disease Control and Prevention. Guidance for Dental Settings: Centres for Disease Control and Prevention Letter to all primary care dental teams in Wales COVID-19: Outline strategic plan for General Dental Services and updated guidance for General Dental Practice Letter to NHS Dental Services (ref: POL/33888) Letter to general dental practices and community dental services (ref: 001559) Transmission Based Precautions Literature Review: Aerosol Generating Procedures Letter to All Primary Care Dental Teams and Health Boards, 10th Timing of phases 2 and 3 of GDS re-establishment plan AEROSOL GENERATING PROCEDURES (AGPs) Accessed: of General Dentistry, Faculty of General Dental Practice. Implications of COVID-19 for the safe management of general dental practice: A practical guide. London: College of Genreal Dentistry, Faculty of General Dental Practice 2020. 13. Office of The Chief Dental Officer England COVID-19 personal protective equipment (PPE) No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted SHEETS/Recovery%20Phase%20Advice/AGP/AGP%20letter%2030%20may%2020 20.pdf British Orthodontic Society. Slow Speed Handpiece Use In Orthodontic Procedures The BOS Position 2020 SHEETS/Recovery%20Phase%20Advice/BOS%20position%20AGP%209th%20Jun e%202020%20Final.pdf Quantitative and qualitative analysis of particulate production during simulated clinical orthodontic debonds Evaluating Spatter And Aerosol Contamination During Dental Procedures Aerosol-Generating Procedures and Simulated Cough in Dental Anesthesia Evaluation of the spatter-reduction effectiveness of two dry-field isolation techniques Dissemination of aerosol and splatter during ultrasonic scaling: a pilot study Evaluation of Minimum Required Safe Distance between Two Consecutive Dental Chairs for Optimal Asepsis Reduction of Aerosols Produced by Ultrasonic Sealers The effect of rubber dam on atmospheric bacterial aerosols during restorative dentistry Microbial aerosols in general dental practice Measurement of airborne bacteria and endotoxin generated during dental cleaning Comparison of suction device with saliva ejector for aerosol and spatter reduction during ultrasonic scaling Microbial Splatter Discharged from the Oral Cavity of Dental Patients Bacterial aerosols in dental practice -a potential hospital infection problem? Atmospheric contamination during ultrasonic scaling Dental aerosols: microbial composition and spatial distribution Removal efficiency of central vacuum system and protective masks to suspended particles from dental treatment Exposure of patient and dental staff to fine and ultrafine particles from scanning spray Demystifying the mist: Sources of microbial bioload in dental aerosols