key: cord-0779334-zoyrpaws authors: Buhr, Tony L.; Borgers-Klonkowski, Erica; Gutting, Bradford W.; Hammer, Emlyn E.; Hamilton, Shelia M.; Huhman, Brett M.; Jackson, Stuart L.; Kennihan, Neil L.; Lilly, Samuel D.; Little, John D.; Luck, Brooke B.; Matuczinski, Emily A.; Miller, Charles T.; Sides, Rachel E.; Yates, Vanessa L.; Young, Alice A. title: Ultraviolet Dosage and Decontamination Efficacy was Widely Variable Across 14 UV Devices after Testing a Dried Enveloped Ribonucleic Acid Virus Surrogate for SARS-CoV-2 date: 2022-01-27 journal: bioRxiv DOI: 10.1101/2022.01.27.478063 sha: 73fa1e77c47fe7f9ce6151ec33041555b80b2ab5 doc_id: 779334 cord_uid: zoyrpaws Aims The dosages and efficacy of 14 ultraviolet (UV) decontamination technologies were measured against a SARS-CoV-2 surrogate virus that was dried on to different materials for lab and field testing. Methods and Results A live enveloped, ribonucleic acid virus surrogate for SARS-CoV-2 was dried on stainless steel 304 (SS304), Navy Top Coat-painted SS304 (NTC), cardboard, polyurethane, polymethyl methacrylate (PMMA), and acrylonitrile butadiene styrene (ABS) at > 8.0 log10 plaque-forming units (PFU) per test coupon. The coupons were then exposed to UV light during both lab and field testing. Commercial and prototype UV-emitting devices were measured for efficacy; 4 handheld devices, 3 room/surface-disinfecting machines, 5 air-disinfection devices, and 2 larger custom-made machines. UV device dosages ranged from 0.01-729 mJ cm-2. Anti-viral efficacy among the different UV devices ranged from no decontamination up to nearly achieving sterilization. Importantly, cardboard required far more dosage than SS304. Conclusions Enormous variability in dosage and efficacy was measured among the different UV devices. Porous materials limit the utility of UV decontamination. Significance and Impact of the Study UV devices have wide variability in dosages, efficacy, hazards, and UV output over time indicating that each UV device needs independent technical measurement and assessment for product development, and prior to use. variability in test methods which include different virus preparation methods, tests with 124 unpurified vs. purified virus, tests with wet virus or dried virus, presence of organic debris, and 125 differences in porosity of surface materials. Assessments of UV for decontamination must also 126 take into account maintenance since UV lights need to be cleaned in order to maintain dosage 127 (Anonymous 2021a , Anonymous 2021b . 128 Here Ф6 was prepared at >10 log10 PFU ml -1 without post-harvest processing or 129 concentration steps, and then dried on to different materials for >24 hours (h) to make BSL-1 130 live/dead enveloped virus test indicators at ≥ 8.0 log10 PFU coupon -1 . Numerous UV devices 131 were tested in both lab and field trials for both screening and iterative UV product improvement. 132 Virus and host cell preparation was previously described (Buhr et al. 2020 glycerol was 10%. One-ml aliquots of HB10Y were pipetted into screw-cap microfuge tubes 144 with O-rings, and stored at -80°C. HB10Y samples were titered prior to freezing by serially 145 diluting samples in 10 millimolar (mM) of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid 146 (HEPES, Sigma PN#H4034-100G) + 10% Sucrose (Sigma PN #S7903-250G), pH 7.0, and 147 plating on tryptic soy agar (TSA; Hardy Diagnostics, Santa Maria, CA). Plates were inverted and 148 incubated at 26±2°C for 48±2 h to show titers of ~10 9 cells ml -1 . After freezing, tubes were 149 thawed at room temperature (RT, 22±3°C), serially diluted and plated to show sustained viability 150 after long-term storage at -80°C. 151 Ф6 was prepared after inoculating broth cultures of HB10Y. A frozen stock prep of HB10Y 152 was thawed at 22±3°C. HB10Y was added either directly from a frozen stock or by transferring a 153 single colony from a streaked TSA plate to 200 ml of 3% TSB in a 1-l smooth-bottom 154 Erlenmeyer flask with a HEPA cap and incubated at 26±2°C, 200 rev min -1 overnight. Cells were 155 then diluted and grown to mid-log-phase. The host flask was inoculated with 0.5-1 ml of Φ6 at a 156 stock concentration of ~11-12 log10 PFU ml -1 . The culture was incubated at 26±2°C, 200 rev 157 min -1 for 24±2 h. The Ф6 preparation was stored at 4°C until after titering was completed. After 158 titer determination was completed, typically around 11-12 log10 PFU ml -1 , then 1-1.3 ml volumes 159 were aliquoted into 1.5-ml screw-cap tubes with O-rings, inverted and stored at -80°C. 160 For sterilization, SS304 and NTC coupons were rinsed with 18 mega-Ohm-cm, de-172 ionized water, placed on absorbent paper in an autoclave-safe container and autoclaved for 30 173 min at 121 o C, 100 kilopascals. Keyboard keys were removed, trimmed, cleaned with soap, then 174 rinsed with de-ionized water and wrapped in aluminum foil. ABS coupons were similarly rinsed 175 with de-ionized water and wrapped in foil. Cardboard coupons were devoid of noticeable debris, 176 flaws, and ink, and were wrapped in foil. After wrapping in foil, the keyboard keys, ABS, and 177 cardboard were all sterilized via hot, humid air at 95 o C and 90% relative humidity (RH) for 4 h. 178 Polyurethane coupons, having been pre-cut, were soaked in ethanol to remove ink residue left 179 over from the cutting process. They were then rinsed with de-ionized water, sterilized via 180 immersion in 70% ethanol for greater than 20 min, and allowed to dry. All sterilized coupons 181 were stored in sterile containers until used. 182 183 Coupon Inoculation and General Test Design 184 185 Five independent preparations of Φ6 were removed from -80°C storage and thawed at 186 22±3°C. Working inoculum was prepared by transferring stock Φ6 into 50-ml conical tubes 187 containing 10mM HEPES + 10% Sucrose pH 7.0 with a final concentration of ~9 log10 PFU ml -1 . 188 Coupons were inoculated with 0.1 ml of Φ6 working inoculum, and subsequently held at 22±3°C 189 for greater than 24 h to dry and adhere to the material. The keyboard keys were slightly slanted. 190 Therefore, during inoculation and drying, the keys were positioned in a sterilized surface which 191 was elevated on an incline via slats to provide a level inoculation surface. 192 Once the inoculum had dried onto the coupons, they were exposed to UV light from the 193 candidate devices as described in the below sections. The primary spectrometer used for this work is the Ocean Optics Maya 2000 Pro, which is 207 capable of measuring optical spectra from 180 -630 nm with an average bin size of 0.22 nm 208 across the measurable spectrum. The distribution is not strictly linear, but can be specifically 209 determined as necessary for data processing. The spectrometer was used with a fiber bundle 210 (BFL200HS02), which incorporates seven Φ200-µm core fibers into a single high-OH package. 211 This enables the measurement of sources with low output so the spectrometer can both retain a 212 high signal-to-noise ratio and enable the use of a cosine corrector (CCSA2) for most 213 measurements. 214 The Maya 2000 Pro spectrometer was calibrated using a Cathodeon R48 Deuterium Lamp, 215 serial number CH5627. The spectral irradiance from this lamp is in units of mW•m -2 •nm -1 in 5 216 nm intervals from 200 -400 nm. To perform the calibration, the lamp is mounted vertically and 217 positioned so that a horizontal line through the center of the area to be irradiated passes through 218 the center of the lamp emission area, as well as perpendicular to the lamp window. The 219 calibration refers to the spectral irradiance over an approximately 10 mm 2 area in a vertical plane 220 located at a distance of 200 mm from the outside surface of the output window on the lamp. The 221 lamp is operated from a 300-mA power supply, and must be operated continuously for 30 min 222 prior to recording data on the spectrometer. 223 The spectrometer was mounted on an optical table, with a three-axis linear translation 224 stage (Thorlabs LTS300) used to enable precision alignment between the spectrometer fiber 225 sensor head and the source of interest. The three-axis system is capable of measuring a 300 mm x 226 300 mm x 300 mm volume with computer automation using a process-controlled script via the 227 Thorlabs Kinesis software. The data acquisition software used National Instruments LabVIEW 228 for all aspects except direct control of the translation stages. All of the data was written to a 229 single Technical Data Management Streaming data file for post-processing, which enabled all of 230 the measurements to have a common time base for analysis. Post-processing was accomplished 231 with the Jupyter software environment, with discrete Python code blocks to allow for processing 232 of specific sources as needed. The raw TDMS data file is loaded into a cache file on the 233 processing server, and a series of factors and calibrations are applied to prepare the raw data for 234 analysis. Static measurements are relatively simple, as the position is fixed and no further 235 analysis is required. Sweeps in a two-dimensional space with the translation stages requires 236 synchronization of the position with digital fiducial markers to construct an image of the 237 measured plane at a given distance from the source. 238 A focus of this work was to provide information for screening field devices and to 240 provide feedback for iterative product improvement. Specific data for prototypes were 241 deliberately omitted since all prototypes were in the process of iterative improvement. 242 Commercial handheld devices (18-watt, 35-watt) 243 Two commercial handheld devices were acquired and tested, each within a custom test 244 apparatus. The first was the GermAwayUV 18W Handheld UV-C Surface Sanitizer (SKU 245 202110, bulb SKU 195317, CureUV, Delray Beach, FL, USA), a 120V/60Hz device containing 246 two 12.7-cm long, U-shaped (Hg) UV bulbs emitting 254 nm UV-C light ( Figure 1A ). An 247 average intensity of 7.61 mW cm -2 was measured within a decontamination footprint of 4.47 cm 248 x 5.39 cm at a 5-cm standoff distance from the bulb (heat map of UV coverage is shown in 249 Figure 1C ). The second device was the GermAwayUV Premier 35W Handheld UV-C Surface 250 Sanitizer (PN14-110-800-100, EPA Product No. 94850-DV-6, CureUV, Delray Beach, FL, 251 USA), 120V/60Hz handheld containing two Hg bulbs that emit 254 nm UV-C light, with 252 reflective material positioned within the unit to enhance UV coverage ( Figure 1B) . The twin 253 tube bulbs spanned a length of 22.5 cm. The 35W device provided an average intensity of 6.95 254 mW cm -2 at 5-cm standoff distance from the bulb ( Figure 1D ). The 35W handheld was later 255 discovered to contain ineffective ballasts (P/N 14-110-800-100), which negatively impacted 256 results. 257 For testing the two handheld devices, wooden holding chambers were constructed in 258 which the devices could be placed to provide standardized exposures to test materials. They were 259 designed to hold the UV source 5 cm above the surface of a test coupon, to prevent UV 260 reflection, and to allow coupons to be inserted into the apparatus via a sliding tray for a specified 261 time period of virus inactivation and then promptly removed ( Figure 1A and 1B Two additional handheld devices were tested for efficacy of virus inactivation, which 298 were prototypes rather than commercial units. The first prototype was one of two custom 3-D 299 printed proprietary units and featured eight LED strips which emitted 272 nm wavelength UV-C 300 light. The face of the handheld was 320 mm x 100 mm with the LED strips covering 255 mm x 301 60 mm. An average intensity of 12.71 mW cm -2 was measured within a decontamination 302 footprint of 6 cm x 25.5 cm at 5 cm standoff distance from the bulb (Figure 2A and 2B) . The 303 second prototype device utilized three 222 nm UV-C Excimer Lamp Modules installed into a 304 2.54 cm thick white plastic panel with power supply. It is important to note that this was strictly 305 an early prototype undergoing iterative improvements, and the UV sources were spaced too far 306 apart for a wand configuration. An average intensity of 1.54 mW cm -2 was measured at 5 cm 307 standoff distance from an individual module ( Figure 3A and 3B) . The wooden test chambers for the prototype handhelds followed the same design as those 321 for the 18W and 35W devices, with the additional feature of a wooden barrier that removed the 322 need for cardboard to prevent premature UV exposure onto test coupons when the materials were 323 outside the UV chamber. A prototype room-decontamination unit featuring a pulsed Xe UV bulb was tested. The 347 unit consists of a pulsed Xe bulb within a frame intended to be mounted onto a wall, ceiling, or 348 mobile tripod for room decontamination. The UV source emitted a small burst of broad-spectrum 349 light every 6 s with the burst lasting for a short duration. The light spectrum included UV-C, 350 UV-B, UV-A, and violet-blue light. Reflector material was positioned behind the source to 351 enhance UV output. 352 Testing of the modified prototype took place within an enclosure provided by the vendor. 353 The device was mounted at a 2-m, 1-m, and 0.5-m vertical standoff distance above the testing 354 surface. Test coupons were placed below the prototype in sterile petri dishes and aseptic 355 technique was employed to the greatest extent possible while outside of a BSC, to prevent 356 contamination. The coupons contained within Petri dishes were uncovered just prior to the test 357 and re-covered at the conclusion of the exposure times. Independent tests were run for 3 358 exposure times (15, 30, and 60 min), each taken at 0.5-m, 1-m, and 2-m distances from the UV 359 source. These time increments were determined via the recommended cycle lengths from the 360 vendor and corresponded to vendor test data (30 and 60 min only). The device was pre-361 programmed for 30 min run times, therefore for the 15-min increment, coupons were removed 362 from the enclosure without shutting off the device after 15 min had elapsed from the time of the 363 first flash. For the 60-min cycle, two decontamination cycles were run sequentially. 364 Two commercial rolling units designed for room decontamination were purchased. The 366 first was the Xenex Lightstrike (Model PXUV4D, S/N 002628, Xenex Disinfection Systems, San 367 Antonio, TX, USA), which contained one pulsed Xe bulb (broad spectrum across the germicidal 368 spectrum of 200-315 nm), which extends and retracts at the top of the unit and pulsed at a rate of 369 67 flashes per s. An average intensity of 0.02 mW cm -2 was measured at a 1.78 m standoff 370 distance from the bulb, but intensities and dosages at specific wavelengths were not carefully 371 analyzed/dissected since this work was not aimed at correlating specific wavelength dosages 372 within a broad spectrum to kill. The second unit was the Light Emitting Module ("LEM," Rapid 373 UV-C Disinfection Model R3, S/N 473, 120V/12A, STERILIZ, LLC, 150 Linden Oaks, 374 Rochester, NY 14625-2802), which contained a ring of twenty Hg bulbs with a 41-cm diameter 375 that emitted predominantly 254 nm wavelength UV-C light. The device was tested at an 376 exposure distance of 2.63 m from the center of the Hg bulb ring. The length of exposure was 377 controlled based upon the cumulative dosage recorded via the LEM system dosimeters placed 378 next to the test coupons and targeted for exposures of 60, 100, and 140 mJ cm -2 . Coupons were 379 exposed to an average intensity calculated to be 0.23-0.24 mW cm -2 . Due to the different 380 intensities of the UV sources, the devices were set at different distances from test coupons to 381 achieve similar dosages in an attempt to directly compare the killing efficacy of a broad 382 spectrum light source to a 254 nm source. 383 For testing, the Xe or Hg rolling units were positioned in the corner of a triangular area 384 and non-reflective folding panels were set up to prevent UV light exposure to personnel outside 385 of the decontamination area. Magnets were glued to the underside of test coupons prior to 386 inoculation of virus and a black, non-reflective, metal sheet rack was utilized as a support for the 387 test coupons. The rack was bent into a curved shape in an attempt to maintain a constant UV 388 exposure distance to all coupons. Testing of these two devices required transport of coupons to 389 the testing site, and coupons were transported in 50 ml conical tubes at room temperature. 390 Negative control coupons as well as additional shipping controls (inoculated and transported, but 391 not exposed to UV light) were also included. Conditions in the testing room were not aseptic but 392 care was taken to avoid contamination at each step and coupons were only transferred to and 393 from the metal rack using sterile forceps. including below the powered rollers (Figure 4) . Testing of this device required transport of 420 coupons to the testing site, and coupons were transported in 50 ml conical tubes at room 421 temperature. Negative control coupons as well as additional shipping controls (inoculated and 422 transported, but not exposed to UV light) were also included. 423 Two rounds of testing were performed with the conveyer device, with slight differences 424 in experimental setup and UV dosages. For both rounds, dosimeters were first used in trial-and-425 error runs to determine the required run-through time to reach the target UV exposures. The 426 dosimeters used were Roithner LaserTechnick GmbH GIVA-S12SD dosimeters from Vienna, 427 Austria, with dimensions of 4.3-cm x 3.5-cm x 1.8-cm. In the first round of experiments, three 428 dosimeters were horizontally taped to a 2% polyethylene board (46.7-cm x 28.6-cm x 2.54-cm) 429 and were sent through the conveyor to get dosage readings based on exposure time (Figure 4) . 430 After target exposure times were determined, coupons were placed inside sterile Petri dishes and 431 set on the same polyethylene support board before exposure in the conveyer. The first round of 432 testing included exposures of 60 mJ cm -2 (22 s), 100 mJ cm -2 (32 s), and 140 mJ cm -2 (44 s). 433 Conditions within the conveyer for this round were 27.7 °C, 63.2% RH, 0.09 ppm ozone. 434 In the second round of testing, the initial runs were again dosimeter-only to determine 435 exposure times to reach the targeted UV dosages. The same dosimeters were used, but this time 436 they were placed on a ceramic tile (~45.7-cm x 45.7-cm Three prototype devices were also tested that were intended to be installed on the ceiling 468 or wall to provide viral decontamination of the air. These devices followed the same general 469 concept but differed slightly in design and were tested in iterations that featured different UV 470 light sources (Hg and KrCl bulbs). Test setup for these devices was largely similar to the 471 previous devices, with each test being carried out for five coupons, each inoculated from one of 472 five independent viral preparations. Sterile control and extraction control coupons were also 473 included. However, only one coupon material was tested for each device. Because the purpose of 474 these devices is air decontamination, the specific test material employed here was not 475 particularly important so long as the material was non-porous with high extraction efficiency and 476 the materials provided no additional decontamination properties. SS304 was initially used for 477 testing, and was later replaced by quartz glass in one case as it allows greater UV transmittance 478 to maximize the surface area that would be exposed to UV light, similar to the way air particles 479 would be exposed at all angles to direct or reflected UV-C light. Tests were carried out for 5, 10, 480 and 15 s for each device, though the distance from the UV source differed for each device as 481 described below. For all experiments, the devices were powered on for at least 30 min prior to 482 testing to mitigate any start-up fluctuations in UV output. 483 Prototype Device A (Hg bulb and KrCl bulb iterations) 484 Prototype device A featured an internal UV light source within an enclosed chamber. 485 Fans controlled flow into the chamber where air was exposed to UV-C radiation and then 486 exhausted through vents opposite from the fans. The first prototype contained two Philips TUV 487 15W/G15 T8 mercury bulbs emitting 254 nm UV-C light. Three fans were mounted in the device 488 to provide airflow at 3,030 l min -1 total through an effective inner volume of 24.64 l. This leads 489 to a residence time of 0.49 s that air will be exposed to UV radiation within the upper chamber. 490 Exposures were at 5-cm, 10-cm, and 15-cm from the UV source. 491 The second iteration of device A replaced the dual Hg bulb with a single, custom KrCl 492 excimer bulb from Far-UV Sterilay that emitted 222 nm UV-C, with the goal of developing a 493 device with good decontamination efficacy that also posed less of a hazard to personnel exposed 494 to the light source. The modified device A also included Teflon reflective surfaces to resist dirt 495 build-up and provide reflectance of the UV-C light. High purity non-crystalline-fused silica glass 496 plates, also called quartz glass, were added to channel airflow parallel to the UV-C source and 497 increase the total contact time between contaminated air and the UV-C light. This increased the 498 total UV dosage applied to air in the unit, thereby providing greater efficacy. The modified 499 prototype device featured three fans providing 1,700 l min -1 of airflow each into the unit. One fan 500 is always operated with the UV-C power switch. Two additional power switches are present for 501 each additional fan, therefore, the device can operate at 1,700, 3,400, and 5,100 l min -1 airflow. 502 The effective interior volume was 24.33 l. 503 The efficacy of the UV light source within the modified device A (KrCl bulb) was tested 504 with the lid attached. Inoculated quartz glass test coupons were placed individually into a tray 505 and slid inside the unit through slots cut in the frame. Slots were cut at set distances of 4, 10, and 506 20 cm from the center of the UV bulb. These distances were aligned to prominent design features 507 in the box. The 4-cm test distance (4-cm from the center of the bulb or 2-cm from the edge of the 508 bulb) aligned to an average distance from the bulb in the middle or second air flow channel. The 509 10-cm distance aligned to the outer channels just behind the quartz glass, and the 20-cm distance 510 also aligned to the outer channels behind the glass at the furthest distance within the device 511 where air would be exposed to UV-C. airflow into the underside of the unit, and air then exited the frame under and past the UV-C 515 source and then out into the surrounding room air. As with device A, two iterations of the design 516 were tested. The first iteration contained one Philips TUV PL-L 36W/4P Hg bulb. Device B was 517 designed to be mounted to a wall and featured one fan to draw air upwards from underneath the 518 device and exhaust out the top and upper sides. It required a mounting height of 2.15 m in order 519 to ensure that no humans or pets are exposed to the UV-C light coming out the sides of the 520 device. Test exposures for this device were conducted at 5-cm, 10-cm, and 15-cm from the UV 521 source for 5, 10, and 15 s each. Coupons were placed in plastic Petri dishes with lids removed for 522 exposures. 523 The second version of device B contained one KrCl excimer bulb emitting 222 nm UV-C 524 light, the same bulb as in the second iteration of device A. For round 2 of testing, the dosages measured during testing were 13.7 mJ cm -2 (8s), 23.8 682 mJ cm -2 (16s), 40.0 mJ cm -2 (24s), and 56.2 mJ cm -2 (32s). Regardless of dosage variability, the 683 conveyer successfully achieved a ≥3 log10 inactivation out of an 8.4 log10 virus challenge for 684 SS304 at 24 and 32 s, for NTC at 32 s, and for ABS plastic at 32 s time points. For all other 685 materials and round 2 exposure times, it failed to reach the ≥3 log10 PFU threshold inactivation. 686 Figure 6 plots the log10 reduction from the conveyer against dosage on the different 687 materials. The conveyor produced UV dose-dependent inactivation at lower dosages (13.7-56.2 688 mJ cm -2 ), but inactivation leveled off across all surfaces tested at higher dosages (60-140 mJ cm -689 2 ). The size of the shielded virus population was dependent on material porosity since the 690 highest level of inactivation was observed on non-porous SS304, followed by polyurethane, ABS 691 plastic, NTC, and then porous cardboard. In addition, an additional sub-population of virus 692 protected by debris was shielded from exposure to radiation because of the presence of host cell 693 debris as indicated by a flattening of the kill rate across all the materials including smooth 694 SS304. That sub-population of debris-complexed virus manifest may manifest higher resistance 695 to the damaging effects of the UV radiation because of both shielding and drying; it is widely 696 known that UV damage produces covalent bonds in nucleic acid and biochemical reactions 697 involving bond formation typically require a solvent like water. 698 699 Figure 6 were maintained in order to comparatively screen and assess the effectiveness of the UV bulbs 727 used in the different prototypes, particularly since there was so much variability in dosage and 728 efficacy among different UV sources up to this point. This approach helped with iterative 729 assessments and prototype improvements. 730 Mounted Prototypes A, B (Hg bulb and KrCl bulb prototypes), and C (Hg bulb type only): 731 Results for the mounted prototype A, B and C are shown in Tables 3 (log10 reduction) 732 and 4 (log10 survival). For the original prototype A with the Hg bulbs, there was minimal log10 733 reduction at different distances and times against virus-inoculated SS304. A modified prototype 734 version with a greatly optimized internal configuration and a KrCl bulb was tested against virus-735 inoculated quartz glass. Time and cost restrictions prevented a test on virus-inoculated SS304. 736 The modified prototype A unit was determined to require approximately 5 min for the UV-C 737 output to stabilize. The device was verified to emit a peak wavelength of 222 nm with a slight 738 spike at 252 nm likely from the SiO2 glass casing of the bulb (data not shown). This modified 739 prototype A unit showed a significant improvement over the original prototype. There were too 740 many significant changes between the first and second prototypes to isolate any single variable 741 as the primary reason for the improved efficacy. 742 For the original prototype B with a Hg bulb, there was minimal log10 reduction at 743 different distances and times against virus-inoculated SS304. A modified prototype B with a 744 KrCl bulb emitting 222 nm UV was tested. Test results showed worse efficacy results than the 745 original prototype B. Overall, this device was the least effective of the wall-mounted prototypes, 746 and it was not modified as extensively compared to the modified prototype A. documented by regulatory agencies and those limitations also apply to SARS-CoV-2 767 (Anonymous 2021a and 2021b). Nonetheless, UV efficacy was measurable and very high 768 dosages were effective even on relatively porous materials like cardboard. It is unlikely that UV 769 would be useful for highly porous fabrics used to make bags, carpeting and clothing, and those 770 were not tested. In contrast, hot, humid air inactivates dirty microbes with similar kinetics 771 regardless of material porosity (e.g. Buhr et al 2012 Buhr et al , 2015 Buhr et al , 2016 Buhr et al , 2020 . This is a hallmark 772 difference between highly penetrative decontaminants and a surface decontaminant like UV. 773 The prototype medium conveyer generated the highest virus inactivation per 774 dosage. Inoculated coupons were exposed to UV-C light on three sides since the coupons were 775 set on a flat surface during exposure in the conveyer. The big UV box also generated high levels 776 of virus inactivation, but the medium conveyer was highest efficacy dose -1 . In contrast the 777 handheld devices, pulsed Xenon devices, LEM, and the original prototypes A, B, and C, and 778 modified prototype B were all evaluated with a UV source emitted from predominantly one 779 direction with slightly varying angles of exposure. The increased angles of exposure in the 780 conveyer and big box likely improved UV-C penetration. Hence, the unique geometry, design 781 and electronics of each device impacted the effectiveness above and beyond the wavelength and 782 dosage. 783 Anti-viral efficacy among the different UV devices ranged from no decontamination up 784 to nearly achieving enveloped virus sterilization. Enormous variability in dosage and efficacy 785 was measured within and among the different devices. This variability strongly indicated that all 786 UV devices need to be measured for both UV dosage and for anti-viral efficacy before 787 purchasing and using large numbers of these devices. The efficacy of a pulsed Xe bulb was 788 measurable at close distances, but significantly lower than Hg bulbs. However, pulsed Xe 789 devices do have some practical advantages such as requiring minimal warm up time and no Hg 790 toxicity. LEDs are also far more practical than Hg bulbs because LEDs have the lowest hazard, 791 lowest variability in UV output, and the 272 nm LED showed highest efficacy. However, the 792 availability of UV LEDs has been limited, and UV dosages can also be limiting depending on the 793 manufacturer, model, the electronics and overall design of any given device. Longer wavelength 794 UV (272 nm) showed the best efficacy in handheld devices and 272 nm is more penetrating than 795 short wavelengths. However, 222 nm KrCl lights showed measurable efficacy in conjunction 796 with proprietary prototype advancements. 797 Finally, decontamination with UV comes with tradeoffs that affect the decision of the end 798 user. The time of exposure needed to generate efficacy needs to be assessed by end users because 799 long exposure times will limit the utility of UV, especially for handheld and air decontamination 800 devices. Another tradeoff to be assessed by end users is the need for cleaning/maintenance of UV 801 devices to remove dirt/debris that accumulates on the light sources, and/or change light sources. 802 Devices and methods to monitor UV dosage over time are needed to assist in maintenance, a 803 particularly important subject that is rarely addressed. Additional tradeoffs are ozone generation, 804 which can be toxic, and operation times; Hg bulbs in particular require warmup times in order to 805 reach a steady-state. In general, Hg bulbs generate a maximum dosage immediately, and then the 806 dosages were stabilized at a lower level after a warm up period. The Hg devices would have 807 performed better had only this initial dose been tested, but that data would not translate to 808 practical application. Lastly, the end user needs an understanding of the organism(s) to be killed, 809 how it is stabilized in the environment, and the impact of test methods on results, as these factors 810 will impact confidence in any application. Assessment of these tradeoffs will facilitate practical 811 application of UV decontamination. As test standards and UV sources improve, UV will become 812 a more viable option for some decontamination applications. Table 3 . Dosage and efficacy of room-air-irradiating prototypes showing log10 reduction data. 973 Prototypes were tested at representative exposure distances but the exposure times were much 974 longer than expected for application in order to provide modeling data. Bio-efficacy testing on 975 the original prototypes A, B, and C evaluated the performance of the UV light source only. 976 Testing on the modified prototypes A and B evaluated the internal improvements to the device. 977 Thus bio-efficacy data presented would be significantly less if realistic, shorter times were tested. Guidance on SARS-CoV-2 Surrogate Selection Anonymous -United States Food and Drug Administration. (2021a). UV Lights and Lamps: 831 Ultraviolet-C Radiation, Disinfection, and Coronavirus Disinfecting Surfaces with UV Light 835 to Reduce Exposure to SARS-CoV-2 Ebola Virus Persistence in the 838 Environment: State of the Knowledge and Research Needs Density gradient centrifugation: A new separation technique Test method development to 843 evaluate hot, humid air decontamination of materials contaminated with Bacillus anthracis 844 ∆Sterne and B. thuringiensis Al Hakam spores Decontamination of 848 materials contaminated with Francisella philomiragia or MS2 bacteriophage using PES-Solid, a 849 solid source of peracetic acid Test methods and response surface models 853 for hot, humid air decontamination of materials contaminated with dirty spores of Bacillus 854 anthracis ∆Sterne and B. thuringiensis Al Hakam Hot, humid air 857 decontamination of a C-130 aircraft contaminated with spores of two acrystalliferous Bacillus 858 thuringiensis strains, surrogates for Bacillus anthracis Hot, Humid Air Decontamination of Aircraft Confirmed That High 864 Temperature and High Humidity Are Critical for Inactivation of Infectious Ribonucleic Acid (RNA) Virus. Front Bioeng Biotechnol The Effects of Temperature and Relative Humidity on the Viability of the SARS 869 Evaluation of Phi6 871 persistence and suitability as an enveloped virus surrogate Survival of the enveloped 874 bacteriophage Phi6 (a surrogate for SARS-CoV-2) in evaporated saliva microdroplets deposited 875 on glass surfaces Pox Americana: The Great Smallpox Epidemic of 1775-82 Selection of a Biosafety Level 1 (BSL-1) surrogate to 879 evaluate surface disinfection efficacy in Ebola outbreaks: Comparison of four bacteriophages The effects on biologic materials of 882 freezing and drying by vacuum sublimation II. Effect on influenza virus Freezing and freeze-drying of viruses Control Measures for SARS-CoV-2: 887 A Review on Light-Based Inactivation of Single-Stranded RNA Viruses Guidelines for the statistical 890 analysis of a collaborative study of a laboratory disinfectant product performance test 891 method Ultraviolet irradiation doses for 893 coronavirus inactivation -review and analysis of coronavirus photoinactivation studies Transmission of Rhinovirus Colds 897 by Self-Inoculation SARS-CoV-2-Laden Respiratory 899 Aerosol Deposition in the Lung Alveolar-Interstitial Region Is a Potential Risk Factor for Severe 900 Disease: A Modeling Study Respiratory Virus Shedding in Exhaled Breath and Efficacy of Face Masks The influence of stabilizers and rates of freezing on preserving of 906 structurally different animal viruses during lyophilization and subsequent storage Disinfection: is it time to reconsider Spaulding? Packaging, replication and recombination of the segmented genomes of 911 bacteriophage Φ6 and its relatives A Critical Review on Ultraviolet Disinfection Systems 914 against COVID-19 Outbreak: Applicability, Validation, and Safety Considerations Hemagglutinin Stability and Its Impact on Influenza A Virus Infectivity APIC Guideline for selection and use of disinfectants The airborne lifetime of small 922 speech droplets and their potential importance in SARS-CoV-2 transmission Inactivation of virus-containing aerosols by ultraviolet germicidal 925 irradiation Comparative 928 properties of bacteriophage phi6 and phi6 nucleocapsid Physico-chemical characteristics of evaporating respiratory fluid 930 droplets Bacteriophage phi6: a lipid-containing 932 virus of Pseudomonas phaseolicola Inactivation of influenza A viruses in the environment 934 and modes of transmission: A critical review Virus 937 inactivation mechanisms: impact of disinfectants on virus function and structural integrity Airway Mucus 940 From Production to Secretion wall, or tripod-mounted Broad-spectrum None reported 827