key: cord-0778061-4nny9fqa authors: El Shamy, Raghi S.; Swillam, Mohamed A.; Li, Xun title: Optimization of Silicon Nitride Waveguide Platform for On-Chip Virus Detection date: 2022-02-02 journal: Sensors (Basel) DOI: 10.3390/s22031152 sha: 586d2c5f0593d85458820e1973add65e87b925a0 doc_id: 778061 cord_uid: 4nny9fqa This work presents a rigorous and generic sensitivity analysis of silicon nitride on silicon dioxide strip waveguide for virus detection. In general, by functionalizing the waveguide surface with a specific antibodies layer, we make the optical sensor sensitive only to a particular virus. Unlike conventional virus detection methods such as polymerase chain reaction (PCR), integrated refractive index (RI) optical sensors offer cheap and mass-scale fabrication of compact devices for fast and straightforward detection with high sensitivity and selectivity. Our numerical analysis includes a wide range of wavelengths from visible to mid-infrared. We determined the strip waveguide’s single-mode dimensions and the optimum dimensions that maximize the sensitivity to the virus layer attached to its surface at each wavelength using finite difference eigenmode (FDE) solver. We also compared the strip waveguide with the widely used slot waveguide. Our theoretical study shows that silicon nitride strip waveguide working at lower wavelengths is the optimum choice for virus detection as it maximizes both the waveguide sensitivity (S(wg)) and the figure of merit (FOM) of the sensor. The optimized waveguides are well suited for a range of viruses with different sizes and refractive indices. Balanced Mach–Zehnder interferometer (MZI) sensors were designed using FDE solver and photonic circuit simulator at different wavelengths. The designed sensors show high FOM at λ = 450 nm ranging from 500 RIU(−1) up to 1231 RIU(−1) with L(MZI) = 500 µm. Different MZI configurations were also studied and compared. Finally, edge coupling from the fiber to the sensor was designed, showing insertion loss (IL) at λ = 450 nm of 4.1 dB for the design with FOM = 500 RIU(−1). The obtained coupling efficiencies are higher than recently proposed fiber couplers. The coronavirus disease pandemic of 2019 (COVID- 19) is currently an exceptional threat to human lives all over the world. Its expeditious spread has led to millions of cases and hundreds of thousands of deaths in a few months. Almost all countries worldwide were forced to lockdown for several months to limit the spread of the virus, leading to devastating social and economic effects. In general, many people across the globe lose their life due to viral infection diseases [1] . Hence, simple, fast, cheap, and accurate detection of viruses are of great importance. Polymerase chain reaction (PCR) is one of the well-known methods used for virus detection and it is the primary method used currently for COVID-19 detection [2] . Although this technique is highly sensitive and accurate, it is expensive, time-consuming, and involves complex procedures and sample preparation. Optical refractive index (RI) sensing is one of the main integrated optical techniques used for bio-detection [3] [4] [5] [6] [7] [8] . RI sensors offer fast, compact, and cheap detection with high sensitivities. However, RI sensors are not selective as they only detect the change in the medium (clad) refractive index which can occur due to different substances. A widely 500 µm arms' length. We also designed an MZI sensor with waveguide widths above 1 µm that can be easily fabricated in simple and cheap facilities. Finally, fiber edge coupling to the sensors chip was studied and optimized, showing higher coupling efficiencies than recently demonstrated fiber couplers. The analysis and results obtained here are generic, i.e., they can be applied to a wide range of biomolecules with different sizes and refractive indices. Figure 1a shows the Si 3 N 4 strip waveguide proposed for virus detection with width (w) and thickness (h) on SiO 2 substrate and water clad. The waveguide surface is functionalized for selective detection such that only the virus of interest will adhere to the surface and form a layer. More details about the exact functionalization process can be found in [9] [10] [11] . Hence, we model this layer by a thickness h vir equal to the virus diameter d vir , i.e., h vir = d vir , and a refractive index n layer , as shown in Figure 1a . The refractive index n layer is given by Equation (1). The value of n layer changes between the refractive index of the water n water and the refractive index of the virus n vir according to the virus coverage fraction r. n layer = (1 − r) × n water + r × n vir (1) In this case, virus binding to the immobilized antibodies on the waveguide surface will change this layer refractive index which will accordingly change the waveguide mode effective index. We choose h vir = 80 nm which is in the range of the reported diameters for the COVID-19 virus [21, 22] . All the results obtained here are using h vir = 80 nm unless mentioned otherwise. This diameter is relatively small when compared with other viruses. We will see by the end of this section that for the same waveguide dimensions increasing the virus layer thickness (targeting virus diameter) will result in higher waveguide sensitivity S wg . Thus, the optimized waveguides at h vir = 80 nm can be used for a range of viruses with different h vir = d vir . Different operating wavelengths are studied from visible range λ = 450 nm (blue) and λ = 650 nm (red), to near-infrared λ = 980 nm and λ = 1550 nm, and MIR λ = 3600 nm. Material dispersion is considered where silicon nitride, silicon dioxide, and water refractive index data along the wavelength are obtained from [23, 24] . At each operating wavelength, we firstly define the single mode dimensions by determining the maximum width at different thicknesses using the FDE solver [20] , as shown in Figure 1b ,c. Then, we calculate the waveguide sensitivity (S wg ) at different waveguide dimensions (w and h), for both fundamental quasi-TE and fundamental quasi-TM modes, which we will denote as TE and TM for simplicity. Note that, unlike most RI sensors designs, here we calculate the surface waveguide sensitivity, S wg = dn eff /dn layer , not the bulk sensitivity, S wg = dn eff /dn clad , which is more accurate for viral detection. S wg is calculated with n layer around the water index with ∆n layer = 0.001, which means that the waveguides are optimized to have maximum sensitivity when the virus layer index is changed slightly from that of water. This corresponds to a minimum virus coverage (r close to 0). Accordingly, the exact virus refractive index n vir does not affect the obtained results. This makes our analysis independent of the virus refractive index and hence we do not need to have its value. Figure 2a ,b show the waveguide sensitivity of the TE mode and TM mode, respectively, for different widths and thicknesses at λ = 450 nm. Results show that for each waveguide thickness, there is an optimum width that maximizes the waveguide sensitivity. Such behavior is expected [25] . For large waveguide widths, most of the mode field is confined inside the silicon nitride core, resulting in low sensitivity. As the width decreases, the mode becomes less confined and the evanescent field in the cladding increases, increasing the sensitivity. However, for small widths, near cut-off, more field moves to the higher (than clad) refractive index substrate which again decreases the sensitivity [25] . Results also show that as the waveguide thickness increases, the optimum width (w opt ) decreases, and optimum sensitivity increases, which is also expected [25] . Hence, waveguides with a higher aspect ratio (AR), AR = h/w opt , can achieve higher S wg reaching 0.513 for the TE mode with w = 104 nm and h = 300 nm (AR = 2.88). This behavior is similar for all wavelengths. However, high AR waveguide sensors are more challenging to fabricate and expensive as they need a fine mask and complex lithography system to obtain the small waveguide widths needed. Figure 2a ,b show the waveguide sensitivity of the TE mode and TM mode, respectively, for different widths and thicknesses at λ = 450 nm. Results show that for each waveguide thickness, there is an optimum width that maximizes the waveguide sensitivity. Such behavior is expected [25] . For large waveguide widths, most of the mode field is confined inside the silicon nitride core, resulting in low sensitivity. As the width decreases, the mode becomes less confined and the evanescent field in the cladding increases, increasing the sensitivity. However, for small widths, near cut-off, more field moves to the higher (than clad) refractive index substrate which again decreases the sensitivity [25] . Results also show that as the waveguide thickness increases, the optimum width (wopt) decreases, and optimum sensitivity increases, which is also expected [25] . Hence, waveguides with a higher aspect ratio (AR), AR = h/wopt, can achieve higher Swg reaching 0.513 for the TE mode with w = 104 nm and h = 300 nm (AR = 2.88). This behavior is similar for all wavelengths. However, high AR waveguide sensors are more challenging to fabricate and expensive as they need a fine mask and complex lithography system to obtain the small waveguide widths needed. Moreover, at high AR the waveguide sensitivity is very sensitive to width variations. For example, changing the width by only 20 nm for the TE mode with AR = 2.88 will significantly reduce S wg to lower than 0.15, i.e., 3.4 times reduction. Moreover, this optimum width (w opt = 104 nm) is close to the mode cut-off width (w cut-off = 78 nm) and multimode width (w MM = 110 nm). Figure 2c shows that for high thicknesses with low optimum widths (high AR), TE mode can achieve higher S wg than TM mode, while for lower thicknesses (higher w opt and low AR) TM mode exhibit higher S wg than TE mode. This is because the TE/TM modes have field discontinuity at the core edges in the x/y direction; hence, decreasing the width/thickness will increase the evanescent field's amount and, hence, sensitivity. Therefore, TM mode is optimum for cheap and easy to fabricate large feature size sensors. mode width (wMM = 110 nm). Figure 2c shows that for high thicknesses with low optimum widths (high AR), TE mode can achieve higher Swg than TM mode, while for lower thicknesses (higher wopt and low AR) TM mode exhibit higher Swg than TE mode. This is because the TE/TM modes have field discontinuity at the core edges in the x/y direction; hence, decreasing the width/thickness will increase the evanescent field's amount and, hence, sensitivity. Therefore, TM mode is optimum for cheap and easy to fabricate large feature size sensors. Figure 3 shows the optimum Swg and the optimum width (wopt) dependence with the AR (or h) at different wavelengths for the TE and TM mode, respectively. We can see that both the operating wavelength and AR have a significant effect on the obtained Swg. In Figure 3 shows the optimum S wg and the optimum width (w opt ) dependence with the AR (or h) at different wavelengths for the TE and TM mode, respectively. We can see that both the operating wavelength and AR have a significant effect on the obtained S wg . In addition, the highest S wg is obtained at the lowest operating wavelength (λ = 450 nm) and it decreases monotonically as the wavelength increases. It is important to note that, scaling the waveguide dimensions with the wavelength does not result in the same waveguide sensitivity. This is mainly due to the unchanged layer's thickness that changes its refractive index (representing virus attachment). Results also show that TE mode achieves the highest possible S wg at every wavelength. mode. At λ = 1.55 µm Swg = 0.22 while at λ = 3.6 µm Swg = 0.192. In order to obtain slot mode in the visible range, the slot width should be less than 200 nm hence not suitable for virus detection (functionalization). Consequently, strip waveguides are more suitable for virus detection as they can achieve higher Swg at lower wavelengths leading to much higher FOM. In addition, the functionalization process in a tiny 200 nm slot is challenging. Moreover, strip waveguide offers a simple sensor design, for example, there is no need for a strip to slot mode converter. We have also examined Si 3 N 4 slot waveguides (TE mode only). Slot waveguides sensitivity increase as slot width decrease. Here, we used a slot width (w slot ) of 200 nm as this is the smallest width that can still allow waveguide functionalization [5, 26] . Figure 4a shows the maximum slot waveguide sensitivities at λ = 1.55 µm and λ = 3.6 µm for the TE mode. At λ = 1.55 µm S wg = 0.22 while at λ = 3.6 µm S wg = 0.192. In order to obtain slot mode in the visible range, the slot width should be less than 200 nm hence not suitable for virus detection (functionalization). Consequently, strip waveguides are more suitable for virus detection as they can achieve higher S wg at lower wavelengths leading to much higher FOM. In addition, the functionalization process in a tiny 200 nm slot is challenging. Moreover, strip waveguide offers a simple sensor design, for example, there is no need for a strip to slot mode converter. virus size. It is important to note that, the optimum waveguide dimensions do not change significantly from the one obtained for hvir = 80 nm, by changing the virus size. Hence, the same waveguide can be used for a range of viruses with different diameters. Moreover, as mentioned above, our analysis is independent of the virus refractive index. Thus, this work can be considered as a universal virus detection method using the SiNOI waveguide platform where the optimized waveguides are well suited for various viruses with different sizes and refractive indices. While waveguide sensitivity is an important parameter, the RI optical sensors' overall performance is determined by the FOM. In both interferometers and resonators, the sensitivity (S) is proportional to Swg × λ. However, the FOM is proportional to Swg/λ because the FWHM is proportional to λ 2 . Hence, operating the sensor at lower wavelengths will achieve the highest performance as Swg increases and λ decreases, maximizing the FOM. Figure 5 shows fitted curves of both Swg × λ and Swg/λ terms versus wavelength for different AR. It can be seen that, FOM increased around 8 times from NIR (λ = 1.55 µm) to visible (λ = 450 nm) wavelength for both TE and TM modes while the sensitivity decreased only 1.4 times. Moreover, working in the visible wavelength range has another advantage for biosensing as in this range the losses due to water absorption are minimized. From more than 200 dB/cm mode loss at λ = 3.6 µm to less than 3 × 10 −3 dB/cm in the visible range. While all the previous results are obtained using a virus layer thickness h vir of 80 nm, we also tested the optimized waveguides for different virus diameters (i.e., different h vir ) from 60 nm to 200 nm. Figure 4b shows that the waveguide sensitivity increases with the virus size. It is important to note that, the optimum waveguide dimensions do not change significantly from the one obtained for h vir = 80 nm, by changing the virus size. Hence, the same waveguide can be used for a range of viruses with different diameters. Moreover, as mentioned above, our analysis is independent of the virus refractive index. Thus, this work can be considered as a universal virus detection method using the SiNOI waveguide platform where the optimized waveguides are well suited for various viruses with different sizes and refractive indices. While waveguide sensitivity is an important parameter, the RI optical sensors' overall performance is determined by the FOM. In both interferometers and resonators, the sensitivity (S) is proportional to S wg × λ. However, the FOM is proportional to S wg /λ because the FWHM is proportional to λ 2 . Hence, operating the sensor at lower wavelengths will achieve the highest performance as S wg increases and λ decreases, maximizing the FOM. Figure 5 shows fitted curves of both S wg × λ and S wg /λ terms versus wavelength for different AR. It can be seen that, FOM increased around 8 times from NIR (λ = 1.55 µm) to visible (λ = 450 nm) wavelength for both TE and TM modes while the sensitivity decreased only 1.4 times. Moreover, working in the visible wavelength range has another advantage for biosensing as in this range the losses due to water absorption are minimized. From more than 200 dB/cm mode loss at λ = 3.6 µm to less than 3 × 10 −3 dB/cm in the visible range. In this section, different MZI sensors have been designed to convert the change in the waveguide's effective index to a sensible quantity for virus detection. The Si3N4 waveguide surface will be functionalized with the virus antibodies. In this case, when the sensor is exposed to the sample the targeted virus will be selectively captured by the waveguide. Virus binding will change the refractive index of the 80 nm layer covering the waveguide core. Accordingly, a wavelength shift (Δλ) in the transmission spectrum of the MZI will occur, from which the virus concentration can then be determined. For an MZI device with power evenly divided to its arms, the transmission spectrum can be derived to be [27] where Δφ the phase difference of the MZI arms; neff,sens, neff,ref and Lsens, Lref are the waveguide mode effective index and length of the sensing and reference arms of the MZI sensor, respectively. From which we can get the peak wavelengths as: where q is an integer. Accordingly, the free spectral range (FSR), full-width half maximum (FWHM), sensitivity (S) and FOM of the MZI sensor can be derived as follows [27] : In this section, different MZI sensors have been designed to convert the change in the waveguide's effective index to a sensible quantity for virus detection. The Si 3 N 4 waveguide surface will be functionalized with the virus antibodies. In this case, when the sensor is exposed to the sample the targeted virus will be selectively captured by the waveguide. Virus binding will change the refractive index of the 80 nm layer covering the waveguide core. Accordingly, a wavelength shift (∆λ) in the transmission spectrum of the MZI will occur, from which the virus concentration can then be determined. For an MZI device with power evenly divided to its arms, the transmission spectrum can be derived to be [27] : where ∆ϕ the phase difference of the MZI arms; n eff,sens , n eff,ref and L sens , L ref are the waveguide mode effective index and length of the sensing and reference arms of the MZI sensor, respectively. From which we can get the peak wavelengths as: where q is an integer. Accordingly, the free spectral range (FSR), full-width half maximum (FWHM), sensitivity (S) and FOM of the MZI sensor can be derived as follows [27] : FOM is the main performance parameter of any RI sensor as it determines the minimum detectable refractive index change. Table 1 shows the dimensions and FOM of different symmetric MZI (s-MZI) sensors designs, L sens = L ref = L MZI , at different wavelengths with AR≈1, L MZI = 500 µm, and ideal y-junction for comparison. The optimized strip waveguides from the previous analysis with the virus layer around the core are used as the sensing arm with width w sens . Oxide-capped waveguides are used as the reference arm with width w ref . These results are obtained using an FDE solver to determine n eff (λ) of the sensing and reference waveguides. Next, an integrated photonics circuit simulator [28] is used to determine T(λ) at different n layer (virus concentration) from which S, FWHM, and FOM are then calculated. Results exhibit the same response as Figure 5 with around 8 times greater FOM at the lower (blue) wavelength. Table 1 also shows FOM at λ = 450 nm for different AR, reaching a maximum of 1231 RIU −1 at AR = 2.88. As mentioned before, at higher waveguide widths, TM mode was used as it can reach higher S wg than TE mode, see Figure 2c . Note that, MIR range was discarded due to its low S wg and high (water absorption) losses. Although small waveguide dimensions in the visible range exhibit high sensing performance, the fabrication of such waveguides requires complex and expensive lithography systems such as electron beam or deep UV lithography. Hence, we want to determine a sensor's performance with a feature size above 1 µm, which will allow for easy and cheap fabrication. While lower wavelengths exhibit higher performance, the blue wavelength has almost zero sensitivity for small AR waveguides with w opt > 1 µm. Hence, we choose to compare two designs both with TM mode. The first design is operating at low (red) wavelength λ = 650 nm exhibiting S wg of 0.115, and the second is operating at a higher wavelength at λ = 980 nm but demonstrating a slightly higher S wg of 0.13. Table 2 shows the dimensions and the FOM of both MZI sensor designs. We can see that the first design operating at a lower (red) wavelength with AR = 0.05 has a higher FOM of 158 RIU −1 even if it exhibits slightly lower S wg . Table 2 . FOM of S-MZI sensors with large feature size using TM mode at LMZI = 500 µm. The minimum detectable index change of the virus layer can be calculated from [29] as ∆n min = 1/FOM. These values can then be converted to minimum detectable virus coverage r min using Equation (1). Table 3 shows ∆n min and r min for the MZI sensors designs at the blue wavelength with different AR and the design at red wavelength optimized for large dimensions (AR = 0.05) with L MZI = 500 µm. Note that, lower virus concentrations (coverage r) can be detected by increasing the FOM by increasing the MZI sensor length as given in Equation (8) . It is important to note that, silicon nitride waveguides with film thickness greater than 300 nm suffer significant stress, and different techniques are used to overcome this problem [30] [31] [32] . However, our analysis shows that thin silicon nitride waveguides, with h < 300 nm, in the visible range are of better sensing performance. In this case, such stress is reduced and a homogeneous index and thickness can be obtained using low-pressure chemical vapor deposition (LP-CVD) [32] . Finally, different MZI configurations were studied and compared for sensing, namely, symmetric MZI (s-MZI), asymmetric MZI (a-MZI), and loop-terminated MZI (LT-MZI) shown in Figure 6 . The simulated results of the different configurations are summarized in Table 4 for the design of TM mode with w sens = 270 nm, h = 100 nm, and w ref = 300 nm at λ = 450 nm and L sens = 500 µm. While s-MZI (L sens = L ref ) sensitivity is determined only by its waveguide structures, i.e. ∆n eff = n eff,sens −n eff,ref , a-MZI (L sens = L ref + ∆L) sensitivity can be engineered using ∆L = L sens −L ref , according to Equation (7) . However, both structures will exhibit almost the same FOM for the same L sens . On the other hand, LT-MZI is a recently proposed design [33] that consists of a conventional MZI with a loop connecting the output directional coupler arms, reflecting the wave back to the interferometer. For the same waveguide structure and L sens , LT-MZI will exhibit the same sensitivity with the conventional MZI while the FWHM will reduce to half resulting in twice the FOM. The LT-MZI directional couplers are also assumed to be ideal 3-dB couplers. The asymmetric LT-MZI can also be used to control the sensitivity using ∆L as in the a-MZI case. Recently, many efforts have been done to couple light from fiber to Si 3 N 4 platform in the NIR range (around 1.55 µm) [34] [35] [36] , reaching a measured coupling efficiency as low as −1.75 dB [34] , using a bottom multilayer reflector and an apodized grating coupler. However, few works have been published for coupling in the visible wavelength range [37] [38] [39] . In this section, we study the coupling from single-mode fibers [40] in the visible region (blue and red) to the silicon nitride chip through edge coupling again using an FDE solver. We focus on the coupling to the TM mode sensors designs mentioned in the previous section, which can achieve high coupling efficiencies and high FOM with waveguide widths larger than 250 nm, see Tables 1 and 2. Design 1: w sens = 550 nm, h = 70 nm (AR = 0.13) and Design 2: w sens = 270 nm, h = 100 nm (AR = 0.37), both at λ = 450 nm. While Design 3: w sens = 1500 nm, h = 80 nm (AR = 0.05) at λ = 650 nm for a large feature size sensor (w > 1 µm). Figure 7a shows the coupling efficiency at blue and red wavelengths to a waveguide with thickness h = 20 nm and h = 40 nm, respectively. A maximum coupling efficiency of 93% and 92.7% can be achieved from the fiber to the waveguide TM mode at λ = 450 nm with w = 600 nm and at λ = 650 nm with w = 565 nm, respectively. Note that, waveguides with higher thicknesses exhibit significantly lower coupling for w > 250 nm. Hence, there is a mismatch between the waveguide dimensions with optimum fiber coupling (w cpl , h cpl ) and optimum sensing (w sens , h sens ), as shown in Figure 7b . Accordingly, the coupling between these two waveguides was studied and the insertion loss (IL) was determined for the different sensing waveguides. For each design, we optimize the waveguide-waveguide coupling, w cpl × h cpl → w out × h sens , by changing the output waveguide width (w out ), which can then be converted to w sens with significantly low losses using a taper. Hence, for the blue wavelength the IL from the fiber to the optimum coupling waveguide, w cpl = 600 nm, and h cpl = 20 nm, is 0.3 dB. The waveguide-waveguide coupling for the sensing waveguide with h sens = 70 nm (Design 1) shows IL = 3.8 dB with an optimum w out of 2600 nm. While for the sensing waveguide with h sens = 100 nm (Design 2) IL = 4.8 dB at w out = 2700 nm. Hence, the overall fiber coupling loss to the sensing waveguide is 4.1 dB and 5.1 dB, respectively. For the red wavelength (Design 3), with w > 1 µm, the fiber-coupling waveguide IL is 1.37 dB at w cpl = 1030 nm and h cpl = 40 nm. While the waveguide-waveguide coupling exhibits IL = 1.1 dB for w out = 1940 nm to the sensing waveguide with h sens = 80 nm, resulting in an overall coupling loss of 2.47 dB. These designs exhibit higher coupling efficiencies than most fiber couplers proposed for the Si 3 N 4 platform at the same wavelength range [37] [38] [39] . This is mainly due to the different waveguide dimensions, as the optimum waveguides for sensing have small core thickness dimensions; thus, exhibiting a large mode size which leads to better matching with the fiber mode. The recently proposed fiber couplers and our proposed ones are summarized in Table 5 . hsens = 80 nm, resulting in an overall coupling loss of 2.47 dB. These designs exhibit higher coupling efficiencies than most fiber couplers proposed for the Si3N4 platform at the same wavelength range [37] [38] [39] . This is mainly due to the different waveguide dimensions, as the optimum waveguides for sensing have small core thickness dimensions; thus, exhibiting a large mode size which leads to better matching with the fiber mode. The recently proposed fiber couplers and our proposed ones are summarized in Table 5 . We propose a Si 3 N 4 strip waveguide to be used as the sensing arm in different integrated optical sensors configurations for virus detection. Integrated RI sensors offer fast, cheap, and simple detection when compared with the existing methods such as PCR, which is expensive and involves complex procedures. Our theoretical study shows that the Si 3 N 4 strip waveguide sensors can achieve high sensitivity, and with surface functionalization, they can detect only a specific virus for high selectivity. Our numerical analysis determines the waveguide dimensions that maximize the sensitivity to the virus layer attached to its surface. The optimum dimensions were determined for different wavelengths from the visible to the MIR and for both fundamental quasi-TE and quasi-TM modes. In addition, we compared the silicon nitride strip waveguide with the slot waveguide. The results show that strip waveguide operating at low wavelengths is the best choice for virus detection. MZI sensors were designed offering a FOM as high as 1231 RIU −1 for L MZI = 500 µm at λ = 450 nm. Finally, edge coupling from the fiber to the waveguide sensor was studied, showing only 4.1 dB insertion loss at λ = 450 nm for the MZI design with FOM = 500 RIU −1 . Our work forms a universal virus detection method using the SiNOI waveguide platform. This is because the optimized waveguides are well suited for various viruses with different sizes, refractive indices, and generally for the detection of different biomolecules using functionalized waveguide surfaces. The Top 10 Causes of Death High levels of HIV-1 in plasma during all stages of infection determined by competitive PCR Integrated optical Mach-Zehnder interferometer based on organic-inorganic hybrids for photonics-on-a-chip biosensing applications Label-free real-time optical monitoring of DNA hybridization using SiN Mach-Zehnder interferometer-based integrated biosensing platform Highly sensitive Mach-Zehnder interferometer biosensor based on silicon nitride slot waveguide Design, manufacture, and testing of a silicon nitride ring resonator-based biosensing platform Microring resonator biosensing platform for sensitive detection of thrombin A highly sensitive metal-insulator-metal ring resonator-based nanophotonic structure for biosensing applications A silicon photonic biosensor using phase-shifted Bragg gratings in slot waveguide A novel optical biosensing system using Mach-Zehnder-type optical waveguide for influenza virus detection Fast, ultrasensitive virus detection using a young interferometer sensor Silicon nitride photonic integration for visible light applications A versatile silicon-silicon nitride photonics platform for enhanced functionalities and applications Silicon Photonics: Silicon nitride versus silicon-on-insulator Review of recent progress on silicon nitride-based photonic integrated circuits Large-scale silicon nitride nanophotonic phased arrays at infrared and visible wavelengths On-chip frequency comb generation at visible wavelengths via simultaneous second-and third-order optical nonlinearities Visibleto-near-infrared octave spanning supercontinuum generation in a silicon nitride waveguide High-Q silicon nitride microresonators exhibiting low-power frequency comb initiation Myocardial localization of coronavirus in COVID-19 cardiogenic shock Optical properties of silicon nitride Handbook of Optical Constants of Solids Sensitivity enhancement in Si nanophotonic waveguides used for refractive index sensing Label-free optical biosensing with slot-waveguides Mid infrared integrated MZI gas sensor using suspended silicon waveguide PIC Design and Simulation Software-Lumerical Interconnect Lumerical Silicon photonic biosensors using label-free detection Overcoming Si 3 N 4 film stress limitations for high quality factor ring resonators Linear and nonlinear characterization of low-stress high-confinement silicon-rich nitride waveguides Low-loss singlemode PECVD silicon nitride photonic wire waveguides for 532-900 nm wavelength window fabricated within a CMOS pilot line A compact silicon-on-insulator gas sensor A high efficiency silicon nitride waveguide grating coupler with a multilayer bottom reflector Multi-layer silicon nitride-on-silicon polarization-independent grating couplers High-efficiency apodized-imaging chip-fiber grating coupler for silicon nitride waveguides Silicon nitride CMOS-compatible platform for integrated photonics applications at visible wavelengths Grating devices on a silicon nitride technology platform for visible light applications Visible-light silicon nitride waveguide devices and implantable neurophotonic probes on thinned 200 mm silicon wafers Thorlabs a Global Manufacturer of Photonic Tools-THORLABS