key: cord-0777365-j1q647o6 authors: Chan, Ming-Jen; Li, Yi-Jung; Wu, Chao-Ching; Lee, Yu-Chen; Zan, Hsiao-Wen; Meng, Hsin-Fei; Hsieh, Meng-Hsuan; Lai, Chao-Sung; Tian, Ya-Chung title: Breath Ammonia Is a Useful Biomarker Predicting Kidney Function in Chronic Kidney Disease Patients date: 2020-10-31 journal: Biomedicines DOI: 10.3390/biomedicines8110468 sha: fc454bada2a3c3ee3bd3604e0cca19fac64f66db doc_id: 777365 cord_uid: j1q647o6 Chronic kidney disease (CKD) is a public health problem and its prevalence has increased worldwide; patients are commonly unaware of the condition. The present study aimed to investigate whether exhaled breath ammonia via vertical-channel organic semiconductor (V-OSC) sensor measurement could be used for rapid CKD screening. We enrolled 121 CKD stage 1–5 patients, including 19 stage 1 patients, 26 stage 2 patients, 38 stage 3 patients, 21 stage 4 patients, and 17 stage 5 patients, from July 2019 to January 2020. Demographic and laboratory data were recorded. The exhaled ammonia was collected and rapidly measured by the V-OSC sensor to correlate with kidney function. Results showed no significant difference in age, sex, body weight, hemoglobin, albumin level, and comorbidities in different CKD stage patients. Correlation analysis demonstrated a good correlation between breath ammonia and blood urea nitrogen levels, serum creatinine levels, and estimated glomerular filtration rate (eGFR). Breath ammonia concentration was significantly elevated with increased CKD stage compared with the previous stage (CKD stage 1/2/3/4/5: 636 ± 94; 1020 ± 120; 1943 ± 326; 4421 ± 1042; 12781 ± 1807 ppb, p < 0.05). The receiver operating characteristic curve analysis showed an area under the curve (AUC) of 0.835 (p < 0.0001) for distinguishing CKD stage 1 from other CKD stages at 974 ppb (sensitivity, 69%; specificity, 95%). The AUC was 0.831 (p < 0.0001) for distinguishing between patients with/without eGFR < 60 mL/min/1.73 m(2) (cutoff 1187 ppb: sensitivity, 71%; specificity, 78%). At 886 ppb, the sensitivity increased to 80% but the specificity decreased to 69%. This value is suitable for kidney function screening. Breath ammonia detection with V-OSC is a real time, inexpensive, and easy to administer measurement device for screening CKD with reliable diagnostic accuracy. Chronic kidney disease (CKD) has become an emerging public health problem and a major economic and social burden. The prevalence is estimated to be as high as 11-13% in the general population, and it is associated with increased cardiovascular diseases and mortality compared ammonia detection [26] . The sensing system is portable and the detection requires only 30 s. To suppress the influence of the humidity on breath ammonia detection, the collected exhaled gas was quickly dehumidified within a few seconds and the relative humidity in the sensing chamber was fixed at around 10%. The details of gas collection and system operation are given in the experimental section. The fabrication cost for the sensor chips is extremely low to be able to serve as disposable chips. Previous breath ammonia clinical tests validated the function of the V-OSC sensors. Compared with other methods, this V-OSC sensors have some merits including small size of the device, low cost, and possible point-of-care feasibility. Although good correlations between breath ammonia and BUN have been demonstrated in hemodialysis patients [11, 12, 20, 26] , studies using breath ammonia to predict the occurrence of CKD are rare. One study compared breath ammonia in 27 CKD stage 3-5 patients with 15 healthy subjects [22] . Another study analyzed the difference between breath ammonia in eight CKD stage 4-5 patients and six healthy volunteers [27] . Both studies showed that breath ammonia concentration was significantly higher in CKD patients compared to healthy individuals. Our recent study also demonstrated that breath ammonia concentration was strongly correlated with the BUN level in 34 CKD stage 3-5 patients, and it was a good predictor to distinguish healthy individuals and these CKD patients [28] . However, these studies used healthy subjects as controls and had a small-number size, and their results require verification by large-scale studies. In this study, we determined whether breath ammonia was a useful screening tool to distinguish between all stages of CKD patients in a study with a larger sample size. We enrolled different CKD stages patients in our outpatient clinic of nephrology department from July 2019 to January 2020. One hundred and twenty-one CKD patients including 19 stage 1 patients, 26 stage 2 patients, 38 stage 3 patients, 21 stage 4 patients, and 17 stage 5 patients were enrolled in this study. We excluded patients less than 20 years old. We also excluded the patients with cirrhosis or liver dysfunction, with active gastrointestinal bleeding, with active infection, and with cancer under active treatment. Patients with admission to hospital within one month were also excluded. The CKD categories and the severity of reduced GFR were defined according to the CKD classification of Kidney Disease Outcome and Quality Initiative (K/DOQI) as stage 1 (eGFR ≥ 90 mL/min/1.73 m 2 and kidney damages), stage 2 (60-89 mL/min/1.73 m 2 ; mild GFR decline), stage 3 (30-59 mL/min/1.73 m 2 ; moderate GFR decline), stage 4 (15-29 mL/min/1.73 m 2 ; severe GFR decline) and stage 5 (<15 mL/min/1.73 m 2 ). The demographic characteristics and comorbidities including diabetes, hypertension, congestive heart failure (CHF) and coronary artery disease (CAD) were recorded. Results of laboratory tests including hemoglobin, albumin, BUN, and serum creatinine were collected for analysis. The eGFR was calculated using the Modification of Diet in Renal Disease Study equation. Administered medicine including steroids, angiotensin converting enzyme inhibitor/angiotensin II receptor blocker (ACEi/ARB) and proton pump inhibitor (PPI) were also recorded. All patients provided a written informed consent to participate in this study. Ethics approval was obtained from the Medial Ethics Committee of Linkou Chang Gung Memorial Hospital on 21 June 2018. (IRB number 201800857B0). The measurement of exhaled ammonia was conducted in the morning. For the sake of convenience in kidney function screening, fasting was not mandatory in order to fit the simplicity of real-world application. To collect the exhaled breath samples, participants were asked to profoundly inhale through the nose and then exhale into a 500 mL plastic bag (the first bag) using a short straw through their mouth. The breath sample in the first bag was soon transferred into a second bag by passing through a desiccation cylinder (that was filled with sodium hydroxide [NaOH] . particles) within 3-5 s. Then, the second plastic bag was immediately connected to the inlet of the Gas Measurement System. It is noted that, when pressing the breath sample through the NaOH tube, NaOH particles also trap a small amount of ammonia. This might cause ammonia concentration deviation in low concentration regime. (i.e., 100-200 ppb) The gas measurement system used in our previous reports was used in this study [26, 27, 29] . As shown in Figure 1 , the system is composed of a rotameter, pump, desiccation cylinder, the sensing chamber, and an electrical signal measurement instrument (Keysight U2722A USB Modular Source Measure Unit, Keysight Technologies, Santa Rosa, CA, USA). The current of the gas sensor chip (biased at 5 V) inside the sensing chamber was measured in real time using U2722A. The gas sensor chip (Taiwan Patent, 108143915) was reported in our previous research [27, 29] . The gas flow rate was fixed at 500 mL/min and ambient air was mixed with the background gas. With continuous pumping of ambient gas to pass through the desiccation cylinder (filled with NaOH), the relative humidity (RH) in the sensing chamber was fixed at approximately 10% and was monitored in real time using a hygrometer. It is noted that the NaOH tube simultaneously suppress the relative humidity and also the CO2 level in the collected sample to avoid the interference due to the formation of carbonic acid in the condensed water film on the sensing layer. When the second bag was connected to the inlet of the system, the breath sample was pumped into the sensing chamber with a fixed RH of approximately 10%. After a fixed sensing time of 30 s, the second bag was removed from the inlet and the background ambient gas entered the chamber again. through their mouth. The breath sample in the first bag was soon transferred into a second bag by passing through a desiccation cylinder (that was filled with sodium hydroxide [NaOH] . particles) within 3-5 s. Then, the second plastic bag was immediately connected to the inlet of the Gas Measurement System. It is noted that, when pressing the breath sample through the NaOH tube, NaOH particles also trap a small amount of ammonia. This might cause ammonia concentration deviation in low concentration regime. (i.e., 100-200 ppb) The gas measurement system used in our previous reports was used in this study [26, 27, 29] . As shown in Figure 1 , the system is composed of a rotameter, pump, desiccation cylinder, the sensing chamber, and an electrical signal measurement instrument (Keysight U2722A USB Modular Source Measure Unit, Keysight Technologies, Santa Rosa, CA, USA). The current of the gas sensor chip (biased at 5 V) inside the sensing chamber was measured in real time using U2722A. The gas sensor chip (Taiwan Patent, 108143915) was reported in our previous research [27, 29] . The gas flow rate was fixed at 500 mL/min and ambient air was mixed with the background gas. With continuous pumping of ambient gas to pass through the desiccation cylinder (filled with NaOH), the relative humidity (RH) in the sensing chamber was fixed at approximately 10% and was monitored in real time using a hygrometer. It is noted that the NaOH tube simultaneously suppress the relative humidity and also the CO2 level in the collected sample to avoid the interference due to the formation of carbonic acid in the condensed water film on the sensing layer. When the second bag was connected to the inlet of the system, the breath sample was pumped into the sensing chamber with a fixed RH of approximately 10%. After a fixed sensing time of 30 s, the second bag was removed from the inlet and the background ambient gas entered the chamber again. Continuous variables are presented as the mean ± standard errors and categorical variables are expressed as the number (%). For comparisons of breath ammonia concentrations between two CKD stages, variables were analyzed using the Student's t-test. For comparisons among five CKD groups, continuous variables were analyzed using a one-way analysis of variance (ANOVA), while Continuous variables are presented as the mean ± standard errors and categorical variables are expressed as the number (%). For comparisons of breath ammonia concentrations between two CKD stages, variables were analyzed using the Student's t-test. For comparisons among five CKD groups, continuous variables were analyzed using a one-way analysis of variance (ANOVA), while categorical variables were compared using the chi-square test (Table 1) . p-values less than 0.05 were considered to be statistically significant. The accuracy of breath ammonia and BUN to distinguish between the two different categories was evaluated using the receiver operating characteristic (ROC) curve analysis. The correlation analysis used Spearman's correlation coefficient. Values of p < 0.05 were considered to be statistically significant. CKD, chronic kidney disease; BUN, blood urea nitrogen; CHF, congestive heart failure; CAD, coronary heart disease; DM, diabetes mellitus; eGFR, estimated glomerular filtration rate; ACEi, angiotensin converting enzyme inhibitor; ARB, angiotensin receptor II blocker; PPI, proton pump inhibitor. One hundred twenty-one patients with different CKD stages were divided into five groups according to their CKD stages (1) (2) (3) (4) (5) . Among these patients, 19 patients (15.7%) were CKD stage 1, 26 (21.5%) were stage 2, 38 (31.4%) were stage 3, 21 (17.4%) were stage 4, and 17 (14.0%) were stage 5. The mean eGFR was 116 ± 5.7, 75 ± 1.4, 48 ± 1.3, 20 ± 1.0 and 9 ± 0.6 mL/min/1.73 m 2 , respectively. Demographics and laboratory measurements are summarized in Table 1 . The average age of CKD patients was 61.9 ± 15.6 years and patients with CKD stage 1 or 2 were younger than patients with CKD stage 3/4/5 (p < 0.001). There was no difference in sex or body weight in the different CKD stage groups. Comorbidities including CHF, CAD, and diabetes did not differ between the groups. The proportion of hypertension, which is a common complication in CKD patients, was significantly higher in the CKD stage 2-5 group compared with the CKD stage 1 group (p = 0.010). Hemoglobin and albumin levels were not different in these CKD groups. As expected, BUN levels that were increased in all CKD patients were proportionally increased with CKD progression. The serum albumin level was not different between the groups. Steroids that increase protein catabolism and subsequently facilitate BUN production were used only in a few patients and the difference in steroid use was similar between the groups. The use of PPIs that suppress gastric acid secretion and reduce exhaled ammonia was not different in the groups. ACEi and ARB can protect against CKD progression but may temporarily reduce kidney function and cause hyperkalemia, especially in patients with advanced CKD [30, 31] . The use of ACEi/ARB in the CKD stage 5 group was significantly lower than that in other CKD groups. To determine whether the use of ACEi/ARB affected breath ammonia, patients were divided into two groups according to the use of ACEi/ARB. The result showed that the breath ammonia concentration was 3146 ± 567 parts per billion (ppb) in the ACEi/ARB group and 3895 ± 815 ppb in the non-ACEi/ARB gourp, which was not significantly different (p = 0.442). Our previous study demonstrated a good correlation between breath ammonia concentration and BUN levels in healthy individuals and CKD stage 3-5 patients [29] . In this study, we assessed the correlation between breath ammonia concentration and BUN levels in all-stage CKD patients including CKD stage 1-2 patients. The result of the Spearman's correlation analysis demonstrated a strong correlation between breath ammonia concentrations and BUN levels (R = 0.723, p < 0.0001) (Figure 2A) . Similarly, the natural logarithm transformation of breath ammonia was strongly correlated with BUN levels (R = 0.756, p < 0.0001; Figure 2B ). Our previous study demonstrated a good correlation between breath ammonia concentration and BUN levels in healthy individuals and CKD stage 3-5 patients [29] . In this study, we assessed the correlation between breath ammonia concentration and BUN levels in all-stage CKD patients including CKD stage 1-2 patients. The result of the Spearman's correlation analysis demonstrated a strong correlation between breath ammonia concentrations and BUN levels (R = 0.723, p < 0.0001) (Figure 2A) . Similarly, the natural logarithm transformation of breath ammonia was strongly correlated with BUN levels (R = 0.756, p < 0.0001; Figure 2B ). We further determined the correlation between breath ammonia and kidney function. Breath ammonia concentrations were strongly correlated with serum creatinine levels (R = 0.735, p < 0.0001; Figure 2C ) and negatively correlated with eGFR (R = −0.535, p < 0.0001; Figure 2D ). These results suggest that breath ammonia has a strong correlation with kidney function in all CKD patients regardless of CKD stages. Our previous study showed a positive correlation between breath ammonia concentration and salivary pH value [29] . The result of the Spearman's correlation analysis also showed that salivary pH values were significantly correlated with breath ammonia concentrations (R = 0.656, p < 0.0001; Figure 2E ). Salivary pH values were also positively correlated with the BUN levels (R = 0.640, p < 0.0001; Figure S1A ) and serum creatinine levels (R = 0.677, p < 0.0001; Figure S1B ), but negatively correlated with eGFR (R = −0.682, p < 0.0001; Figure S1C ). We further determined the correlation between breath ammonia and kidney function. Breath ammonia concentrations were strongly correlated with serum creatinine levels (R = 0.735, p < 0.0001; Figure 2C ) and negatively correlated with eGFR (R = −0.535, p < 0.0001; Figure 2D ). These results suggest that breath ammonia has a strong correlation with kidney function in all CKD patients regardless of CKD stages. Our previous study showed a positive correlation between breath ammonia concentration and salivary pH value [29] . The result of the Spearman's correlation analysis also showed that salivary pH values were significantly correlated with breath ammonia concentrations (R = 0.656, p < 0.0001; Figure 2E ). Salivary pH values were also positively correlated with the BUN levels (R = 0.640, p < 0.0001; Figure S1A ) and serum creatinine levels (R = 0.677, p < 0.0001; Figure S1B ), but negatively correlated with eGFR (R = −0.682, p < 0.0001; Figure S1C ). Because progressive decline in kidney function causes accumulation of nitrogen metabolites including ammonia, we determined whether breath ammonia was increased with CKD progression. We first determined breath ammonia concentrations in patients with different CKD stages. Our results showed that the mean concentration of breath ammonia in this study was 3898 ± 6760 and it increased with increasing CKD stages as followed: 636 ± 94 ppb in CKD stage 1 patients, 1020 ± 120 ppb in CKD stage 2 patients, 1943 ± 326 ppb in CKD stage 3 patients, 4421 ± 1042 ppb in CKD stage 4 patients, and 12781 ± 1807 ppb in CKD stage 5 patients ( Table 1) . The difference in the breath ammonia concentration between each stage was statistically significant and the concentration was increased with increasing CKD stages (Figure 3 ). This result suggests that breath ammonia concentration could be used to predict CKD stages. Because progressive decline in kidney function causes accumulation of nitrogen metabolites including ammonia, we determined whether breath ammonia was increased with CKD progression. We first determined breath ammonia concentrations in patients with different CKD stages. Our results showed that the mean concentration of breath ammonia in this study was 3898 ± 6760 and it increased with increasing CKD stages as followed: 636 ± 94 ppb in CKD stage 1 patients, 1020 ± 120 ppb in CKD stage 2 patients, 1943 ± 326 ppb in CKD stage 3 patients, 4421 ± 1042 ppb in CKD stage 4 patients, and 12781 ± 1807 ppb in CKD stage 5 patients ( Table 1) . The difference in the breath ammonia concentration between each stage was statistically significant and the concentration was increased with increasing CKD stages (Figure 3 ). This result suggests that breath ammonia concentration could be used to predict CKD stages. Box plot is used to display breath ammonia concentration in different CKD group, and significant differences between groups are indicated (*, p < 0.05; **, p < 0.01; ***, p < 0.001; ****, p < 0.0001). Our previous study demonstrated a simultaneous increase of breath ammonia and salivary pH in advanced CKD patients [29] . To assess whether salivary pH was increased in CKD patients, salivary pH value was measured in our CKD stage 1-5 patients, respectively. As shown in Table 1 , salivary pH levels were proportionally elevated with increased CKD stages (p < 0.001). The pH value in each stage was significantly higher than that in previous stage and Figure S2 ). To determine the predictive value of breath ammonia concentration to distinguish between CKD stage 1 and other CKD stages (2-5), the ROC curve analysis was used. The result showed that the AUC of breath ammonia was 0.835 (p < 0.0001). The cutoff value of 974 ppb had a best predictive value to distinguish between CKD stage 1 and other CKD stages, with a sensitivity of 69%, a specificity of 95%, a positive predictive value (PPV) of 0.99 and a negative predictive value (NPV) of 0.36 ( Figure 4A ). The ROC curve analysis results also demonstrated that the AUC for differentiating Exhaled breath ammonia concentrations were measured in chronic kidney disease (CKD) stage 1-5 patients. Box plot is used to display breath ammonia concentration in different CKD group, and significant differences between groups are indicated (*, p < 0.05; **, p < 0.01; ***, p < 0.001; ****, p < 0.0001). Our previous study demonstrated a simultaneous increase of breath ammonia and salivary pH in advanced CKD patients [29] . To assess whether salivary pH was increased in CKD patients, salivary pH value was measured in our CKD stage 1-5 patients, respectively. As shown in Table 1 , salivary pH levels were proportionally elevated with increased CKD stages (p < 0.001). The pH value in each stage was significantly higher than that in previous stage and Figure S2 ). To determine the predictive value of breath ammonia concentration to distinguish between CKD stage 1 and other CKD stages (2-5), the ROC curve analysis was used. The result showed that the AUC of breath ammonia was 0.835 (p < 0.0001). The cutoff value of 974 ppb had a best predictive value to distinguish between CKD stage 1 and other CKD stages, with a sensitivity of 69%, a specificity of 95%, a positive predictive value (PPV) of 0.99 and a negative predictive value (NPV) of 0.36 ( Figure 4A ). The ROC curve analysis results also demonstrated that the AUC for differentiating CKD stage 1 from early CKD (stage 2 and 3) was 0.751 (p < 0.001). At the cutoff value of 974 ppb, the sensitivity was 53%, specificity was 95%, PPV was 0.97, and NPV was 0.38 ( Figure 4B ). CKD stage 1 from early CKD (stage 2 and 3) was 0.751 (p < 0.001). At the cutoff value of 974 ppb, the sensitivity was 53%, specificity was 95%, PPV was 0.97, and NPV was 0.38 ( Figure 4B ). Because the K/DOQI CKD classification defines CKD as GFR<60 mL/min/1.73 m 2 for more than three months, the cutoff value of the ROC curve analysis was calculated to distinguish patients between eGFR ≥ 60 mL/min/1.73 m 2 and patients with eGFR < 60 mL/min/1.73 m 2 . As shown in Figure 4C , the AUC was 0.831 (p < 0.0001) with a sensitivity of 71%, a specificity of 78%, a PPV of 0.84, and a NPV of 0.61 at the cutoff value of 1187 ppb. Our findings showed that breath ammonia concentration was increased with the progression of CKD stages and that there was a strong correlation between breath ammonia and kidney function. Thus, we evaluated whether measurement of breath ammonia could be used as a screening tool for the occurrence of CKD. According to the definition of CKD that was established by KDIGO, the patients were divided into two groups by eGFR≥ or <60 mL/min. The sensitivity and specificity of breath ammonia concentration in predicting patients with eGFR < 60 mL/min are shown in Table 2 . At a concentration of 993 ppb, the breath ammonia test had a sensitivity of 75% and a specificity of 73%. To increase the test sensitivity to 80%, breath ammonia was set at a concentration of 886 ppb, and the specificity decreased to 69%. This result suggests that for a non-life threating or non-serious CKD, breath ammonia at a cutoff concentration of 886 ppb is a good screening tool for detection of patients with potential CKD. Because the K/DOQI CKD classification defines CKD as GFR<60 mL/min/1.73 m 2 for more than three months, the cutoff value of the ROC curve analysis was calculated to distinguish patients between eGFR ≥ 60 mL/min/1.73 m 2 and patients with eGFR < 60 mL/min/1.73 m 2 . As shown in Figure 4C , the AUC was 0.831 (p < 0.0001) with a sensitivity of 71%, a specificity of 78%, a PPV of 0.84, and a NPV of 0.61 at the cutoff value of 1187 ppb. Our findings showed that breath ammonia concentration was increased with the progression of CKD stages and that there was a strong correlation between breath ammonia and kidney function. Thus, we evaluated whether measurement of breath ammonia could be used as a screening tool for the occurrence of CKD. According to the definition of CKD that was established by KDIGO, the patients were divided into two groups by eGFR≥ or <60 mL/min. The sensitivity and specificity of breath ammonia concentration in predicting patients with eGFR < 60 mL/min are shown in Table 2 . At a concentration of 993 ppb, the breath ammonia test had a sensitivity of 75% and a specificity of 73%. To increase the test sensitivity to 80%, breath ammonia was set at a concentration of 886 ppb, and the specificity decreased to 69%. This result suggests that for a non-life threating or non-serious CKD, breath ammonia at a cutoff concentration of 886 ppb is a good screening tool for detection of patients with potential CKD. CKD has an increasing prevalence and incidence, and it is now a worldwide public health problem and a major economic burden. Because early diagnosis is crucial for prevention and delay of adverse CKD outcomes, finding a rapid, low-cost, and non-invasive screening method to identify CKD patients is important. In this study, we used a portable, real-time biosensor to measure exhaled breath ammonia in CKD patients to determine whether breath ammonia could be used as a simple and real-time indicator of kidney function. Our previous study and Wang's study showed a good correlation between breath ammonia concentration and BUN level in CKD stage 3-5 patients [29, 32] . This study enrolled more patients, including CKD stage 1-2 patients, and confirmed the good correlation between breath ammonia and BUN. In addition, breath ammonia concentration was strongly correlated with the serum creatinine level and eGFR. Bayrakli et al. also reported a good correlation between breath ammonia and eGFR [33] . These results all suggest that breath ammonia could be a useful surrogate of kidney function. Measurement of serum creatinine with calculation of eGFR is the most commonly and easily used method to assess kidney function, but it requires blood withdrawal and laboratorial analysis. The real-time detection of the breath ammonia by V-OSC sensor like finger-stinged blood sugar monitoring provides a fast and easy-to-use assessment of kidney function. Our result demonstrated that breath ammonia concentration was proportionally increased with CKD progression because the concentration at each stage was significantly higher than that at the previous stage (CKD stage 1, 636 ± 94 ppb; stage 2, 1020 ± 120 ppb; stage 3, 1943 ± 326 ppb; stage 4, 4421 ± 1042 ppb; stage 5, 12,781 ± 1807 ppb). Although breath ammonia measurement has been reported to be well correlated with the BUN level in hemodialysis patients, studies that have assessed its use in CKD screening is rare. As per our knowledge, only two studies were performed and they used different methods including an external cavity laser (ECL)-based off-axis cavity-enhanced absorption spectroscopy and an electrochemical gas sensor analyzed breath ammonia concentrations in 27 CKD stage 3-5 and eight CKD stage 4-5 patients, respectively [33, 34] . Both studies showed that compared with healthy individuals, these CKD patients had significantly higher breath ammonia levels Our recent study also showed the usefulness of breath ammonia to predict CKD stage 3-5 occurrence. This study enrolled more advanced CKD patients in a different hospital, further demonstrating a significantly increase in the mean breath ammonia concentration with increasing CKD stages [29] . In addition, compared with other studies, the advantage of our device was a portable design and rapid detection (within 5 min) [15, 35, 36] . The K/DOQI working group defines decreased GFR as GFR < 90 mL/min/1.73 m 2 . Compared with patients with eGFR ≥ 90 mL/min/1.73 m 2 (CKD stage 1), patients with eGFR < 90 mL/min/1.73 m 2 (CKD stage 2-5) had higher breath ammonia concentration. The ROC curve analysis showed that breath ammonia is a good predictor (AUC, 0.835) to distinguish between individuals with and without eGFR ≥ 90 mL/min/1.73 m 2 . At a cutoff value of 974 ppb, the sensitivity and the specificity were 69% and 95%, respectively, and there was a high PPV of 0.99, but a low NPV of 0.36. Similarly, breath ammonia is an acceptable indicator (AUC, 0.751) to differentiate between patients with eGFR ≥ 90 mL/min/1.73 m 2 (CKD stage 1) and patients with a mild to moderate GFR decline (CKD stage 2 and 3) because there was a high specificity (95%) and high PPV (0.97), but there was a low sensitivity (53%) and low NPV (0.38). These results suggest that an elevated breath ammonia concentration more than 974 ppb is a reliable indicator to predict eGFR < 90 mL/min/1.73 m 2 because 99% of patients with breath ammonia > 974 ppb had eGFR < 90 mL/min/1.73 m 2 . However, 64% of patients with a breath ammonia concentration below 974 ppb may still have eGFR < 90 mL/min/1.73 m 2 . Thus, breath ammonia monitoring can be used to screen asymptomatic CKD patients, but it still requires an eGFR assessment in the high-risk population. Normal GFR varies with age, and older individuals may have normal kidney physiological function in the range of GFR 60-89 mL/min/1.73 m 2 [37] [38] [39] . Because GFR < 60 mL/min/1.73 m 2 is considered to reflect abnormal kidney function in all ages, the K/DOQI CKD classification defines CKD as GFR < 60 mL/min/1.73 m 2 for more than three months. Thus, we assessed whether breath ammonia could be used as a predictor to distinguish between patients with and without eGFR < 60 mL/min/1.73 m 2 . The AUC of the ROC curve analysis was 0.831 and at a cutoff value of 1187 ppb, the PPV was 0.84. These results suggest that a breath ammonia concentration > 1187 ppb has a good diagnostic accuracy to verify patients with eGFR < 60 mL/min/1.73 m 2 . However, only 71% of patients with eGFR < 60 mL/min/1.73 m 2 were identified at this concentration. For non-fatal disease screening, a good predictor requires a good diagnostic accuracy with adequate sensitivity. To screen for patients with reduced GFR < 60 mL/min/1.73 m 2 , our results showed that a breath ammonia concentration set at 886 ppb had a sensitivity of 80% but the specificity was reduced to 69%. Because serum creatinine is commonly monitored in routine health examination and consequences of false negative and positive results for CKD detection are modest without immediate hazards, a sensitivity of 80% for CKD screening is acceptable. We believe that breath ammonia measurement at this cutoff value could be a useful tool for CKD screening. ACEi and ARB can cause hyperkalemia and GFR reduction in some patients and no randomized controlled trials have verified the safety and efficacy in patients with advanced CKD [30] . This may explain why, in this study, the proportion of ACEi/ARB use in the CKD stage V group was less than that in other CKD groups. However, there was no significant difference in the breath ammonia concentrations in the ACEi/ARB and non-ACEi/ARB groups in patients with CKD stage 1-4. Obermeier et al. reported that ACEi/ARB did not affect exhaled breath ammonia [6]. Our results are consistent with their finding, suggesting that ACEi/ARB use has no effect on breath ammonia concentration. Steroids are sometimes used in some CKD patients, especially in patients with glomerulonephritis-mediated CKD, and this can increase the metabolic rate and cause an increase in the BUN level. In this study, steroid use was not different in these CKD patients, suggesting that breath ammonia monitoring is useful in CKD patients taking steroids. Our study also showed that salivary pH was positively correlated to BUN, and breath ammonia concentrations. Salivary pH values were significantly higher in the patients with more advanced CKD stages than earlier stages, which is compatible with our previous study [29] . Ammonia is basic and the increase in salivary pH value could be attributed to the hydrolysis of increased salivary urea to a higher salivary NH3 concentration by bacterial urease in patients with impaired kidney function [40] . The correlation between pH values and breath ammonia has been reported by Schmidt et al. [11] . The breath ammonia (NH3) is formed as the volatile part of NH4+, which is the product of the hydrolysis reaction of salivary urea. As a result, the salivary pH level will affect the concentration ratio between NH3 and NH4+ through the fundamental chemical reaction following Henderson-Hasselbalch equation. Limitations of this study include older age in CKD stage 3-5 patients compared with CKD stage 1-2 patients. However, this may be caused by the nature of CKD and the age factor did not affect breath ammonia concentration (R = 0.105, p = 0.253, Figure S3 ). Second, many reports found that the breath ammonia level was affected by food or water intake [11, 13] . Thus, most previous studies analyzed 4-6 h-fasting breath ammonia. In this study, fasting was not required, and the effect of fasting was not analyzed. However, for user convenience, the fasting requirement may place a limitation on the real-world application of this screening method. Regardless of the fasting requirement, our data still demonstrated the usefulness of breath ammonia in CKD screening. Finally, despite a larger case number in this study compared with previous studies, enrollment of more subjects is required to verify the usefulness of this CKD screening method. To achieve this goal, we combined the data from 45 CKD stage 1-2 patients and 76 CKD stage 3-5 patients in this study and 34 CKD stage 3-5 patients from our recent study and reanalyzed the data. The results of the re-analyzed ROC curve analysis still demonstrated that breath ammonia measurement was a good method for screening patients with eGFR < 60 mL/min/1.73 m 2 because the AUC was 0.834, sensitivity was 83%, specificity was 56%, PPV was 0.82, and NPV was 0.57 at a cutoff value of 973 ppb ( Figure S4 ). Screening for CKD is important because it is a significant public health burden with a high prevalence worldwide and early diagnosis can delay and reduce morbidity and mortality. Detection of exhaled breath ammonia that is real-time, inexpensive, and easy to administer with an acceptable diagnostic accuracy and sensitivity can be used as a good surrogate of kidney function and a reliable tool for CKD screening. Global, regional, and national age-sex specific mortality for 264 causes of death, 1980-2016: A systematic analysis for the Global Burden of Disease Study Global Prevalence of Chronic Kidney Disease-A Systematic Review and Meta-Analysis Global costs attributed to chronic kidney disease: A systematic review Prevalence, awareness, and management of CKD and cardiovascular risk factors in publicly funded health care Awareness of kidney disease in the US population: Findings from the National Health and Nutrition Examination Survey (NHANES) 1999 to 2000 Biomedicines 2020 Exhaled volatile substances mirror clinical conditions in pediatric chronic kidney disease Volatile organic compounds in uremia Quantitative analysis of ammonia on the breath of patients in end-stage renal failure Breath analysis in patients with end-stage renal disease: Effect of haemodialysis Ammonium metabolism in humans Ammonia in breath and emitted from skin Exhaled breath volatile organic and inorganic compound composition in end-stage renal disease Biochemical pathways of breath ammonia (NH3) generation in patients with end-stage renal disease undergoing hemodialysis Breath ammonia and trimethylamine allow real-time monitoring of haemodialysis efficacy Breath ammonia levels in a normal human population study as determined by photoacoustic laser spectroscopy Breath analysis of ammonia, volatile organic compounds and deuterated water vapor in chronic kidney disease and during dialysis Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis Real-time monitoring of breath ammonia during haemodialysis: Use of ion mobility spectrometry (IMS) and cavity ring-down spectroscopy (CRDS) techniques Screening tests: A review with examples Selected ion flow tube mass spectrometry analysis of volatile metabolites in urine headspace for the profiling of gastro-esophageal cancer Point of Care Monitoring of Hemodialysis Patients with a Breath Ammonia Measurement Device Based on Printed Polyaniline Nanoparticle Sensors Molecular breath analysis identifies the breathprint of renal failure Nanosensor and Breath Analyzer for Ammonia Detection in Exhaled Human Breath Highly selective and sensitive gas sensors for exhaled breath analysis using CuBr thin film Highly sensitive ammonia sensor for diagnostic purpose using reduced graphene oxide and conductive polymer A Versatile Method to Enhance the Operational Current of Air-Stable Organic Gas Sensor for Monitoring of Breath Ammonia in Hemodialysis Patients Organic Gas Sensor with an Improved Lifetime for Detecting Breath Ammonia in Hemodialysis Patients Molecular Adsorbent Recirculating System: Clinical experience in patients with liver failure based on hepatitis B in China Correlation between breath ammonia and blood urea nitrogen levels in chronic kidney disease and dialysis patients ACE inhibitors and ARBs: Managing potassium and renal function Should We STOP Angiotensin Converting Enzyme Inhibitors/Angiotensin Receptor Blockers in Advanced Kidney Disease? Nephron Estimation of clinical parameters of chronic kidney disease by exhaled breath full-scan mass spectrometry data and iterative PCA with intensity screening algorithm Applications of external cavity diode laser-based technique to noninvasive clinical diagnosis using expired breath ammonia analysis: Chronic kidney disease, epilepsy Measurement of breath ammonia for detection of patients with chronic kidney disease Concentrations of some metabolites in the breath of healthy children aged 7-18 years measured using selected ion flow tube mass spectrometry (SIFT-MS) Diagnostic potential of breath analysis-focus on volatile organic compounds CKD: A Call for an Age-Adapted Definition Estimating renal function in old people: An in-depth review Structural and Functional Changes in Human Kidneys with Healthy Aging Evaluation of salivary parameters and dental status in adult hemodialysis patients in an indian population The authors would like to thank Shu-Ting Gan (the Center for Big Data Analytics, Chang-Gung Memorial Hospital) for the statistical consultation. We also thank Chia-Jung Lu (Department of Chemistry, National Taiwan Normal University, Taipei, Taiwan) to correct the discussion section of the revised manuscript All authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.