key: cord-0777259-8sjkfxyk authors: Clinkard, D.; Mashari, A.; Karkouti, K.; Fedorko, L. title: Evaluation of N95 respirators, modified snorkel masks and low‐cost powered air‐purifying respirators: a prospective observational cohort study in healthcare workers date: 2021-01-20 journal: Anaesthesia DOI: 10.1111/anae.15392 sha: d5f6860f309201c2977d118d488033b936c2f99b doc_id: 777259 cord_uid: 8sjkfxyk Disposable N95 respirator masks are the current standard for healthcare worker respiratory protection in the COVID‐19 pandemic. In addition to shortages, qualitative fit testing can have low sensitivity for detecting poor fit, leading to inconsistent protection. Multiple groups have developed alternative solutions such as modified snorkel masks to overcome these limitations, but validation of these solutions has been lacking. We sought to determine if N95s and snorkel masks with attached high‐efficiency filters provide consistent protection levels in healthcare workers and if the addition of positive pressure via an inexpensive powered‐air purifying respirator to the snorkel mask would provide enhanced protection. Fifty‐one healthcare workers who were qualitatively fitted with N95 masks underwent quantitative mask fit testing according to a simulated workplace exercise protocol. N95, snorkel masks with high‐efficiency filters and snorkel masks with powered‐air purifying respirators were tested. Respiratory filtration ratios were collected for each step and averaged to obtain an overall workplace protocol fit factor. Failure was defined as either an individual filtration ratio or an overall fit factor below 100. N95s and snorkel masks with high‐efficiency filters failed one or more testing steps in 59% and 20% of participants, respectively, and 24% and 12% failed overall fit factors, respectively. The snorkel masks with powered‐air purifying respirators had zero individual or overall failures. N95 and snorkel masks with high‐efficiency filter respirators were found to provide inconsistent respiratory protection in healthcare workers. together, this literature suggests that N95 and comparable respirators do not provide adequate protection against droplets and close-range aerosols. The performance of N95s and other negative-pressure respirators primarily depends on a stable face seal to prevent entrainment of unfiltered air [10] . Consistency of this seal is essential to protect healthcare workers, particularly anaesthetists. Anaesthetists are highly involved in the management of patients with COVID-19, serving on rapid response teams, as well as caring for patients in the operating theatre and critical care units, all roles that involve exposure to aerosol-generating procedures and increased SARS-CoV-2 transmission risk [2] . Limited global supply of N95 and comparable disposable and re-usable respirators has led to the development of alternative methods of respiratory protection, including altering commercially available masks designed for other industries and applications, potentially resulting in inconsistent protection. Snorkel masks originally designed for underwater use have been widely repurposed during the current pandemic and modified with attached high-efficiency filters because they are widely available and offer full-face protection [11] . However, snorkel masks, like N95s, require a stable facial seal. In the absence of rigorous testing, snorkel masks may provide a false sense of security to healthcare workers [12] . Powered air-purifying respirators (PAPRs) offer the highest level of protection when dealing with virulent airborne pathogens [13] , were utilised extensively by the Chinese airway teams and may have led to the low healthcare worker infection rate seen in Wuhan [14] . Unfortunately, their limited availability has precluded their widespread use in the current pandemic. Further modification of snorkel masks with a small inexpensive fan to provide filtered positive air pressure and convert this into a PAPR could potentially overcome the requirement of a consistent facial seal and may provide an accessible option with superior protection. We sought to determine the failure patterns and filtration efficacy of snorkel masks with a high-efficiency filter, and snorkel masks equipped with a PAPR in comparison to qualitatively fit-tested single-use N95s in healthcare workers. After obtaining institutional review board approval, a convenience sample of 54 healthcare workers were recruited who had been qualitatively fit tested and trained on disposable N95 mask usage by our institution's occupational health department within the previous year. This was achieved via a hospital-wide email to the perioperative departments asking for volunteers over the first 2 weeks of April 2020. Polyurethane enclosures and adapters were cast using custom-designed 3D-printed moulds created by our team. Two air-guard filters were connected in parallel to the blower and standard 22-mm anaesthetic tubing and oneway valves were used for connections (Fig. 1 ). This device is not approved by any health regulatory agency at present. We enrolled 54 subjects, 51 of which completed the testing. Three subjects withdrew from the study due to time constraints and were not included in the analysis. A total of 357 testing steps were performed on each device. The characteristics of participants are shown in Table 1 . The average fit factor of the snorkel mask with attached PAPR (12, 177) and snorkel mask with high-efficiency filter (2939) was significantly higher than N95s (144) (Fig. 2) . There was a significantly increased failure rate with N95s and the snorkel mask with the high-efficiency filter The pattern and distribution of individual step and overall test results are presented in Fig. 3 . It is important to note that although the standard criteria for an overall pass permits The main finding of this study is that qualitatively fit-tested disposable N95s and snorkel masks with high-efficiency filters have significant failures and do not provide consistent protection in trained and tested healthcare workers. Current mask fit testing protocols can be broadly divided into qualitative and quantitative methods. Qualitative methods rely on detection of a bitter substance such as Bitrex, while quantitative fit testing calculates an internal to external particulate ratio, which is then mathematically averaged to provide a 'pass'. In this study, 35% of participants who had previously suggests that when utilised in the healthcare environment, an unnoticed seal leak in an elastomeric respirator may paradoxically result in worse protection than an N95 [10] . Together, these findings suggest that significant caution should be exercised when considering the use of repurposed snorkel masks for high-risk clinical situations. However, our data show that the risks associated with A limitation of this study is its single-centre design and small sample size. Our sample was recruited by asking for volunteers, which may potentially lead to selection bias, though we attempted to control for this by ensuring a diverse ethnic, age and occupation sample that is broadly reflective of the local population. Our findings suggest that respirators with positive pressure are likely to provide more consistent respiratory protection. Further design and manufacturing optimisation, as well as testing to ensure compliance with technical and Figure 3 Individual results for 51 participants wearing (a) N95; (b) snorkel masks with a high-efficiency filter; and (c) snorkel masks with a powered air-purifying respirator undergoing a seven-step workplace exercise protocol. Results are harmonically averaged to provide an overall simulated workplace protection factor (SWEP-F). Green boxes represent filtration ratios ≥ 100 (pass), red boxes represent filtration ratios < 100 (fail). regulatory standards, are required for cost-effective devices to be brought into routine use in high-risk healthcare settings. CDC COVID-19 Response Team. Characteristics of healthcare personnel with COVID-19 Epidemiology of and risk factors for coronavirus infection in healthcare workers: a living rapid review Aerosol generating procedures and risk of transmission of acute respiratory infections to healthcare workers: a systematic review Airborne or droplet precautions for health workers treating COVID-19? The role of fit testing N95/FFP2/FFP3 masks: a narrative review Effectiveness of N95 respirators versus surgical masks in protecting healthcare workers from acute respiratory infection: a systematic review and meta-analysis Medical masks vs N95 respirators for preventing COVID-19 in healthcare workers: a systematic review and meta-analysis of randomized trials Comparison of qualitative and quantitative fit-testing results for three commonly used respirators in the healthcare sector Respiratory performance offered by N95 respirators and surgical masks: human subject evaluation with NaCl aerosol representing bacterial and viral particle size range Performance comparison of N95 and P100 filtering facepiece respirators with presence of artificial leakage Resuable full-face snorkel mask PPE project Safety testing improvised COVID-19 personal protective equipment based on a modified full-face snorkel mask Respiratory protection against bioaerosols: a literature review and research needs Response of Chinese anesthesiologists to the COVID-19 outbreak CAN/CSA-Z94.4-18: Selection, use, and care of respirators Respiratory protective devices -Selection, use and maintenance -Part 3: Fit-testing procedures NIOSH Anthropometric Data and ISO Digital Head forms 2020 Determining sample size and a passing criterion for respirator fit-test panels We would like to thank Dr S. Barbic for her thoughtful comments. No external funding or competing interests declared.