key: cord-0776217-3jcyrqpa authors: Ikner, Luisa A.; Torrey, Jason R.; Gundy, Patricia M.; Gerba, Charles P. title: Efficacy of an antimicrobial surface coating against human coronavirus 229E and SARS-CoV-2 date: 2021-09-06 journal: Am J Infect Control DOI: 10.1016/j.ajic.2021.08.031 sha: 4bfc0f9d6477c5e78450d18e027e83dfa5b161c5 doc_id: 776217 cord_uid: 3jcyrqpa The COVID-19 pandemic has accelerated the demand for alternatives to standard cleaning and disinfection practices. Continuously-acting coatings may provide an alternative to common surface treatments. A newly-developed quaternary ammonium polymer coating was applied to stainless steel coupons and evaluated for efficacy against human coronavirus 229E and SARS-CoV-2. The polymer coating reduced levels of both test viruses by greater than 99.9% relative to non-coated stainless steel coupons during a two-hour contact time. Background Respiratory viruses remain viable on inanimate, environmental surfaces (i.e., fomites) for extended periods of time depending on temperature, humidity, and other factors. 1 Effective cleaning and surface disinfection practices reduce levels of infectious viruses and the potential for their spread. 2 Nevertheless, recontamination can occur at any time following the use of liquid disinfectants, which are typically wiped dry from surfaces post-application. A number of selfdisinfecting surface formulations have been developed during recent years. 3 A continuouslyactive quaternary ammonium polymer applied to high-touch surfaces by certified technicians using electrostatic sprayers previously resulted in the reduced spread of antibiotic-resistant bacterial infections in clinical settings. 4 The formulation was subsequently modified to increase cationic functionality for more efficient disruption of the lipid bilayers that comprise bacterial membranes and viral envelopes. Human coronavirus 229E (HCoV-229E), a seasonal enveloped respiratory pathogen of humans, has been employed as a surrogate for emergent coronaviruses to assess persistence, survival, and antiviral efficacy. 5 The objective of this study was to assess the antiviral effectiveness of the new formulation following application to stainless steel coupons against SARS-Related Coronavirus 2 (SARS-CoV-2) and HCoV-229E. Acetone-washed, pre-autoclaved stainless-steel coupons (Type 304, unidirectional finish) coated with the reformulated quaternary ammonium polymer (SurfaceWise2™) were supplied by Allied BioScience, Inc (Dallas, Texas). An electrostatic sprayer mounted onto a robotic slide was used to coat the coupons, with coverage uniformity monitored by an x-ray fluorescence (XRF) spectrometer. The coating was cured overnight under ambient conditions. Non-coated stainless-steel coupons were used as control surfaces. The carriers were not subjected to wear and abrasion testing prior to experimentation. Materials E1053-20 Method. 8 Modifications to the method were: 1) the use of stainless-steel coupons, and 2) pre-application of the polymer coating to the coupons followed by inoculation of virus. Test 1 against HCoV-229E (Table 1) was performed by inoculating 0.10 mL of stock virus onto polymer-coated and non-coated control coupons (25.81 cm 2 ) mounted into sterile Petri dishes, with spreading over the surface to within ~0.32 cm of the perimeter edge. The coupons were incubated (22 -23°C; 30 -50% relative humidity) for two hours with the Petri dish lids on. Swabs pre-dipped in Letheen Broth Base (LBB; Neogen Corp., Lansing, MI) were used for product neutralization and to harvest viruses from carriers. The swabs were placed into tubes containing 1 mL of LBB and vortexed vigorously. The suspensions were immediately passed through Sephadex G-10 gel columns by centrifugation (5 minutes at 3,500 x g). Subsequent tests against HCoV-229E (Test 2) and SARS-COV-2 were modified by the addition of 5% soil, and by decreasing the carrier size and viral inoculum volume (Table 1) . A wash method was also employed by rinsing the carriers 4 -5 times using 1 mL of LBB, with further virus detachment using a cell scraper. Gel filtration followed as described. Neutralized suspensions underwent 1:10 serial dilutions using minimal essential media (Mediatech, Inc., Manassas, VA) followed by plating onto host cell monolayers in 96-well trays (six replicates per dilution). Following incubation at 35°C in a 5% CO 2 atmosphere, wells were scored for the presence of cytopathogenic effects (CPE) and cytotoxicity. The method of neutralization was also validated per ASTM E1053-20 (data not shown). Additional assay parameters are listed in Table 1 . Per well assay volume 0.05 mL 0.10 mL 0.10 mL Assay incubation period 9 days 9 days 10 days *FBS: fetal bovine sera The reformulated quaternary ammonium coating achieved > 99.9% reduction of HCoV-229E and SARS-CoV-2 during the 2-hour contact time in the absence and presence of 5% organic soil ( Table 2 ). The wash method for harvesting the carriers facilitated greater viral recovery compared to the swab method. Cytotoxicity was observed in the lowest plated dilution (10 0 ) of Vero E6 cells, while no toxic effects were evident on MRC-5 cells at the 10 0 dilution. Table 2 . Viral recovery (log 10 ) and reduction of HCoV-229E and SARS-CoV-2 on quaternary ammonium polymer-coated coupons relative to non-coated stainless steel carriers at 2 hours *, †, ‡ The results demonstrate similar reductions of > 99.9% (> 3-log 10 ) for HCoV-229E and SARS-CoV-2 following two hours of exposure to the reformulated quaternary ammonium coating applied to stainless steel coupons. However, further studies are warranted to assess effectiveness following application to a variety of non-porous and porous surface types. Recovery levels of both viruses from non-coated study controls after two hours suggest comparative rates of inactivation on Type 304 stainless steel under the environmental conditions implemented, although a larger sample size would be preferable to confirm statistical significance. Cytotoxic effects were observed after plating undiluted (10 0 ) neutralized filtrates from coated carriers onto Vero E6 host cells, while none were observed on MRC-5 cells. Cell monolayer damage typifies cytotoxicity; therefore, dilutions that display such effects are not utilized to calculate log 10 reductions. However, they are determinative in establishing assay detection limits which can vary by orders of magnitude as observed for the HCoV-229E and SARS-CoV-2 assays (< 0.50 log 10 and < 1.50 log 10 , respectively). Surface-active coatings that have antiviral capabilities are not meant to substitute for regular cleaning and disinfection practices, but rather serve as an additional barrier for reducing human exposure to infectious viruses that may be present on fomites. 9 With the recent detection of infectious SARS-CoV-2 from the bedside table, remote control, bed rails, and flooring in the hospital room of an infected patient, 10 the importance of effective hygiene protocols for environmental surfaces remains imperative. Significance of fomites in the spread of respiratory disease and enteric viral disease Control of the spread of viruses in a long-term care facility using hygiene protocols Self-disinfecting surfaces and infection control Impact of a novel antimicrobial surface coating on health care-associated infections and environmental, at 2 urban hospitals Persistence of SARS-CoV-2 in the environment and COVID-19 transmission risk from environmental matrices and surfaces Survival of coronaviruses in water and wastewater Virology Methods Manual Standard practice to assess virucidal activity of chemicals intended for disinfection of inanimate Antimicrobial activity of a continuously active disinfectant against healthcare pathogens Environmental contamination in the isolation rooms of COVID-19 patients with severe pneumonia requiring mechanical ventilation or high-flow oxygen therapy This project was funded by Allied BioScience, Inc.