key: cord-0771114-0uosze8l authors: Acosta, N.; Bautista, M.; Hollman, J.; McCalder, J.; Buchner Beaudet, A.; Man, L.; Waddell, B. J.; Chen, J.; Li, C.; Kuzma, D.; Bhatnagar, S.; Leal, J.; Meddings, J.; Hu, J.; Cabaj, J.; Ruecker, N. J.; Naugler, C.; Pillai, D. R.; Achari, G.; Ryan, M. C.; Conly, J. M.; Frankowski, K.; Hubert, C. R.; Parkins, M. D. title: Wastewater Monitoring of SARS-CoV-2 from Acute Care Hospitals Identifies Nosocomial Transmission and Outbreaks date: 2021-02-23 journal: nan DOI: 10.1101/2021.02.20.21251520 sha: 3b5a36f86bc14c1f4892fd4dba097d77b1143a42 doc_id: 771114 cord_uid: 0uosze8l Background: SARS-CoV-2 has been detected in wastewater and its abundance correlated with community COVID-19 cases, hospitalizations and deaths. We sought to use wastewater-based detection of SARS-CoV-2 to assess the epidemiology of SARS-CoV-2 in hospitals. Methods: Between August and December 2020, twice-weekly wastewater samples from three tertiary-care hospitals (totalling >2100 dedicated inpatient beds) were collected. Wastewater samples were concentrated and cleaned using the 4S-silica column method and assessed for SARS-CoV-2 gene-targets (N1, N2 and E) and controls using RT-qPCR. Wastewater SARS-CoV-2 as measured by quantification cycle (Cq), genome copies and genomes normalized to the fecal biomarker PMMoV were compared to the total daily number of patients hospitalized with active COVID-19, confirmed cases of hospital-acquired infection, and the occurrence of unit-specific outbreaks. Results: Of 165 wastewater samples collected, 159 (96%) were assayable. The N1-gene from SARS-CoV-2 was detected in 64.1% of samples, N2 in 49.7% and E in 10%. N1 and N2 in wastewater increased over time both in terms of amount of detectable virus and the proportion of samples that were positive, consistent with increasing hospitalizations (Pearsons r=0.679, P<0.0001, Pearsons r=0.728, P<0.0001, respectively). Despite increasing hospitalizations through the study period, wastewater analysis was able to identify incident nosocomial-acquired cases of COVID-19 (Pearsons r =0.389, P<0.001) and unit-specific outbreaks by increases in detectable SARS-CoV-2 N1-RNA (median 112 copies/ml) versus outbreak-free periods (0 copies/ml; P<0.0001). Conclusions: Wastewater-based monitoring of SARS-CoV-2 represents a promising tool for SARS-CoV-2 passive surveillance and case identification, containment, and mitigation in acute- care medical facilities. in order to normalize SARS-CoV-2 for the relative bioburden in samples [5] . RT-qPCR was 143 performed using a QuantStudio-5 Real-Time PCR System (Applied Biosystems) with each run 144 including no-template controls (NTCs) in triplicate. For N1, N2 and E-assays three positive 145 controls were included in each run. Samples where minimal signal for BCoV or PMMoV controls 146 were recovered were excluded from the analysis to mitigate false-negative results. Amplified 147 products from wastewater were also Sanger sequenced to confirm amplicons were derived from 148 SARS-CoV-2. Pearson's correlation analyses were performed to determine the correlation of wastewater RNA-154 signal measured as i). Cq, or ii). genome copies/ml of wastewater or iii). genome copies/genome 155 of PMMoV, vs daily-hospitalized cases. To assess for correlation of wastewater RNA-signal with 156 incident hospital-acquired cases, and to compensate for gaps owing to the twice-weekly sampling, 157 incident cases occurring +/-3 days were compared to wastewater signals. To compare the SARS- 158 CoV-2 wastewater N1-signal observed during and between unit-outbreaks, each sample was 159 dichotomized as being collected within 3-days of a declared outbreak or not. Samples after a 160 declared outbreak were excluded until 3-days after the last in-hospital linked case was identified. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Figure S3 ), coinciding with Calgary's COVID-19 'second wave'. We observed that the N1-assay 172 had the best sensitivity for detecting SARS-CoV-2. Of the 96 samples tested using N1, N2 and E-173 assays (i.e., those received between August 1 st and October 29 th ), 9 samples were positive for all 174 three targets, 28 were positive only for N1 and N2, and 39 were positive only for N1. After October 175 29 th the E-assay was dropped, and 69 samples were analyzed, 51 were positive for both N1 and (Table 2) . No-template and blank controls for sample 179 processing and RNA purification were negative for all assays (i.e., N1, N2, E, BCoV and 180 PMMoV). Standard curves for all RT-qPCR assays were within an acceptable range for 181 efficiencies (75 to 162%) and R 2 (0.7 to 1.0) (Supplementary Table-S2) . Hospital-1 had a higher proportion of SARS-COV-2-positive wastewater compared to Hospital-2 183 and Hospital-3, consistent with the higher burden of disease in NE Calgary (Table 1 and Figure 184 1). Following a large outbreak in Hospital-3 involving 45 patients, 43 HCW and 5 visitors 185 (beginning in a ward not monitored via Hospital-3A site and compounded by affected patients being transferred into different units through the hospital) that was declared on September 17 th , 187 wastewater sampling was expanded to include additional sites; Hospital-3B and Hospital-3C 188 ( Figure 2 ) to enable complete capture of Hospital-3. Wastewater SARS-CoV-2 signal correlates with total hospitalized COVID-19 cases 190 We assessed the correlation between the SARS-CoV-2 wastewater-N1 with active-COVID-19 191 patients on contact/droplet isolation at each hospital. When assessed together, Hospital-2, we observed that as prevalent cases increased, the wastewater-signal measured as N1-193 Cq also increased (Pearson's r=0.679, CI: 0.529-0.787, P<0.0001). This was also true when 194 Hospital-1 and Hospital-2 were assessed separately ( Table 2 ). The same was observed when 195 SARS-CoV-2-N1 wastewater was normalized against copies of the PMMoV at Hospital-2, but 196 only trended towards significance at Hospital-1 (Table 2) . These same correlations are not as 197 reliable at the Hospital-3 as we did not have access to prevalent cases as a function of sampling 198 site. However, we continued to observe a positive correlation (Table 2 ) between prevalent cases respect to whether peaks in SARS-CoV-2 in wastewater associated with outbreaks, we compared HCW) may be asymptomatic, pauci-symptomatic, or pre-symptomatic-each just as likely to 231 transmit infection as symptomatic individuals [22] [23] [24] . Despite rigorous infection control protocols, 232 nosocomial infections continue to occur. Novel strategies to understand the epidemiology of 233 SARS-CoV-2 in hospitals are therefore urgently required. One such strategy may be the 234 monitoring of hospital wastewater [25] . To date, most wastewater-based SARS-CoV-2 RNA surveillance has focused on monitoring 236 community burden of disease by sampling WW-TP [5] [6] [7] [8] . More recently, moving sampling 237 'upstream' in the wastewater-network, closer to patients, is actively being explored. The most 238 granular data comes from single-facility assessments. Passive wastewater surveillance could hold 239 promise as an early warning strategy, adaptable to both low-and high-risk facilities. Importantly, 240 if an incipient signal is detected in facility-wide wastewater samples, in-building plumbing systems 241 can be strategically sampled in a nested manner in order to confirm an outbreak location. Here we demonstrate that both the frequency of positive samples and the abundance of SARS- CoV-2 RNA in hospital wastewater systems correlated with increasing hospitalised cases -244 analogous to WW-TP levels correlating with the COVID-19 community-diagnosed cases [5] [6] [7] [8] . This was most evident using raw SARS-CoV-2 Cq values but was also evident when normalized 246 against PMMoV levels. We observed the N1-region of the nucleocapsid gene to be more sensitive 247 than N-2, and E so low as to be dropped from our protocol. Other groups have reported similar 248 trends in that the N1-target is the most sensitive marker in WW-TP studies[4] and cruise ships [26] . Despite nosocomial cases and outbreaks representing a small fraction of the overall population of 250 patients hospitalized with COVID-19, these events were discernable by wastewater testing. The 251 natural history of SARS-CoV-2-RNA presence in the gastrointestinal tract remains incompletely 252 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101/2021.02.20.21251520 doi: medRxiv preprint understood [2, 3] . Changes in fecal viral loads over the course of the disease have not been 253 explored. Extrapolating from our hospital-based wastewater data, it appears that peak fecal viral 254 shedding may occur around symptom onset, given the congruence of wastewater RNA-signal and 255 nosocomial cases and outbreaks identified in hospitals. Based on the rapid decline in wastewater 256 signal thereafter, it is likely that fecal SARS-CoV-2-RNA drops significantly after initial 257 presentation. Indeed, early in the pandemic when fewer patients with COVID-19 were 258 hospitalized, wastewater samples routinely tested negative. This critical observation suggests that wastewater data is to be used in a meaningful way. Similarly, issues arise with attempts to 275 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101/2021.02.20.21251520 doi: medRxiv preprint normalize SARS-CoV-2 based on the contributing population. We chose to use the PMMoV as a There are limitations of our work that merit discussion. Given the complexity involved in sample 294 collection, we were limited to twice-weekly sampling. Knowing how quickly SARS-CoV-2 can 295 spread and outbreaks can occur, a daily monitoring strategy would have much greater capacity to 296 identify and mitigate secondary cases of COVID-19. Incident cases are likely to be clinically 297 diagnosed in hospital far faster than in other high-risk facilities owing to greater resources and 298 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101/2021.02.20.21251520 doi: medRxiv preprint heightened suspicion -potentially leading to an even greater lead-time associated with a positive 299 wastewater-signal of outbreaks than observed herein. Hospitals pose unique challenges in 300 wastewater monitoring owing to these facilities' high use of chemical disinfectants and 301 detergents[33] that could interfere with molecular assays; this may explain why 3.6% of our 302 samples spiked controls and PMMoV were not detected by RT-qPCR. To minimize the risk of 303 false negatives, rigorous protocols that use internal controls (such as our BCoV spike) are 304 necessary. The role of PCR-inhibitors in the wastewater matrix within the proximal sewershed is 305 an area that deserves considerable study if this field is to expand. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101 https://doi.org/10. /2021 In a five-month observational study we were able to detect SARS-CoV-2 from the wastewater of (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101/2021.02.20.21251520 doi: medRxiv preprint collection. The authors are grateful to staff from Alberta Health Services and AHS Infection 338 Prevention and Control for assistance in data collection on patient disposition in the Calgary Zone. The authors also thanks Cameron Semper for providing the pMCSG53 vector and T7/T7 340 terminator primers, and for providing support with Gibson assembly cloning. We would like to 341 acknowledge the tremendous efforts of Dr Rhonda Clark for program administration and 342 management. All authors report no potential conflicts. All authors have submitted the ICMJE Form for 344 Disclosure of Potential Conflicts of Interest. All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101/2021.02.20.21251520 doi: medRxiv preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101/2021.02.20.21251520 doi: medRxiv preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10. 1101 /2021 SARS-CoV-2 from faeces to wastewater treatment: Hospital-2. Relative SARS-CoV-2 genomic copies compared to genomic copies of PMMoV from The authors gratefully acknowledge the staff of the City of Calgary and in particular members of 336 Water Quality Services for their continued efforts for sample site planning, maintenance, and