key: cord-0770152-sn8ywjhr authors: Verbeure, Wout; Geeraerts, Annelies; Huang, I‐Hsuan; Timmermans, Lien; Tóth, Joran; Geysen, Hannelore; Cools, Louise; Carbone, Florencia; Schol, Jolien; Devriese, Herman; Haesaerts, Rico; Mori, Hideki; Vanuytsel, Tim; Tack, Jan title: The effect of an air purifier on aerosol generation measurements during clinical motility testing date: 2021-08-02 journal: Neurogastroenterol Motil DOI: 10.1111/nmo.14227 sha: 2d5dad0fbe9674078241b9f2bf5749d4a4a3e84d doc_id: 770152 cord_uid: sn8ywjhr BACKGROUND: Aerosol spread is key to interpret the risk of viral contamination during clinical procedures such as esophageal high‐resolution manometry (HRM). Installing an air purifier seems a legitimate strategy, but this has recently been questioned. METHODS: Patients undergoing an HRM procedure at the Leuven University Hospital were included in this clinical study. All subjects had to wear a surgical mask which was only lowered beneath the nose during the placement and removal of the nasogastric catheter. The number of aerosol particles was measured by a Lasair(®) II Particle Counter to obtain data about different particles sizes: 0.3; 0.5; 1.0; 3.0; 5.0; and 10.0 µm. Measurements were done immediately before the placement and the removal of the HRM catheter, and one and 5 min after. A portable air purifier with high‐efficiency particle air filters was installed in the hospital room. KEY RESULTS: Thirteen patients underwent a manometry examination. The amount of 0.3 µm‐sized particles was unaffected during the whole procedure. The larger particle sizes (1.0; 3.0; 5.0; and 10.0 µm) decreased when the catheter was positioned, but not 0.5 µm. During the HRM measurements itself, these numbers decreased further. Yet, 1 min after catheter removal a significant elevation of particles was seen, which did not recover within 5 min. CONCLUSIONS & INTERFERENCES: Based on this study, there is no evidence that filtration systems reduce aerosol particles properly during a clinical investigation. study questioned the efficacy of these purifiers and even warned for several drawbacks. 3 In a recent study, no increased risk or aerosol and droplet spread were observed when positioning and removing a nasogastric catheter, in the absence of an air purifier. In the current study, we evaluated the effect of an air purifier on aerosol spread during esophageal high-resolution manometry (HRM). This study protocol was approved by the Ethics Committee of the Leuven University Hospital, Belgium and performed in full accordance with the declaration of Helsinki. The study is published in clinicaltrials.gov with reference number NCT04687488. Patients-with a negative COVID-19 reverse transcriptasepolymerase chain reaction test during the preceding 36 hundergoing an esophageal HRM at the Leuven University Hospital were invited to participate. Patients were requested to wear a mask covering the mouth during nasogastric intubation and removal. The HRM measurements (between positioning and removal) take in general 35 min to perform. The HRM was conducted with a 2.7 mm diameter solid-state catheter (Unisensor, Attikon, Switzerland). Aerosol quantification was performed using the Lasair ® II particle Counter (Particle Measuring Systems, Inc., Unites States), and six sizing channels were measured: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, and 10 µm. A tube connected to the particle counter was placed within 10 cm from the mouth of the patient and every measurement was the result of 1-min counting. The particle counter was calibrated at the beginning of each motility session. Particles were Aerosol particle data (particles-per-cubic-meter) are presented as mean ± SD. SAS University Edition Software (SAS Institute, Cary, NC, USA) was used for all the analyses. Data were logarithmically transformed for repeated one-way ANOVA with stepdown Bonferonni adjustments for multiple testing. Significance was set at p < 0.05. Log number of aerosol particles are presented in Figure 2 . After the installation of the air purifier in the motility room, 13 patients underwent an HRM examination. There was no significant difference in the number of small-sized par- p < 0.0001; p < 0.0001; and p < 0.0001 in ascending particle size order). The number of floating 0.3 µm and 0.5 µm particles did not change during the examination; however, the bigger-sized particles decreased in this 35 min period (p = 0.51; p = 0.70; p = 0.0006, p = 0.0016, p = 0.0015; and p = 0.0048, in ascending order of particle size). There was no additional 0.3 µm sized particle generation, 1 min after removal (p = 0.13), which remained unchanged after 5 min higher levels compared with the start of the examination (before placement of catheter). Actually, all bigger-sized particles were still significantly lower in number (p = 1.00; p = 1.00; p < 0.0001; p < 0.0001; p < 0.0001; and p = 0.0012 in ascending particle size order). Since the COVID-19 outbreak, awareness for pathogen spread via aerosol has grown. All options to reduce the number of airborne particles are being explored, ranging from wearing mouth masks, limiting the number of people inside a room to optimization of room ventilation. In a dental clinical study, the use of an air purifier showed a reduced exposure of airborne droplets and aerosol particles to HCWs when an air cleaner was placed in a suitable position. 4 The U.S. Environmental Protection Agency also suggested that air purifiers can help reduce airborne contaminants via appropriate use. 5 However, currently, the U.S. Centers for Disease Control and Prevention has not provided recommendations to use air purifiers with HEPA filter for decontamination of airborne COVID-19. Furthermore, the use of air purifiers has been questioned as a pilot study observed increased local air flow when a test amount of aerosols and droplets were released near the exhaust outlets. 3 In a recent study, we found that the placement and removal of an HRM catheter or a 24 h multichannel intraluminal impedance-pH monitoring probe, with a number of precautionary measures, do not increase the number of floating aerosol particles of any size, and only results in little droplet spread in the patient's environment. 6 This study was performed without the presence of a purifier in the room. Here, the efficiency of aerosol reduction by an air purifier was evaluated during an HRM examination. During the placement of the catheter, there is no difference in aerosol particle levels with or without purifier. The 0.3 and 0.5 µm remained unchanged, and the heavier particles dropped in numbers. Without purifier, no increase in particles has been seen after catheter removal. 6 After the device's installation, an elevation for study without the purifier. 6 We suggest two plausible explanations: 1) lower numbers of particles right before catheter removal makes a small increase after more noticeable or 2) there is an actual increase of particle spread by the presence of the purifier. In any case, the increased amount of particles does never reach significantly higher levels compared with the moment the patient entered the room. European Society for neurogastroenterology and motility recommendations for conducting gastrointestinal motility and function testing in the recovery phase of the COVID-19 pandemic Prevention of exposure to and spread of COVID-19 using air purifiers: challenges and concerns The effectiveness of an air cleaner in controlling droplet/aerosol particle dispersion emitted from a patient's mouth in the indoor environment of dental clinics Agency USEP Will an air cleaner or air purifier help protect me and my family from COVID-19 in my home?: United States goverment will-air-clean er-or-air-purif ier-help-prote ct-me-and-my-famil ycovid -19-my-home Aerosol generation and droplet spread during nasogastric intubation in the COVID-19 era How to cite this article: Verbeure W, Geeraerts A, Huang The effect of an air purifier on aerosol generation measurements during clinical motility testing