key: cord-0768984-xvw48xjt authors: Lavalle, Carlo; Magnocavallo, Michele; Bernardini, Alessia; Vetta, Giampaolo; Bianchi, Valter; Mattera, Agostino; Mariani, Marco Valerio; Ammendola, Ernesto; Busacca, Giuseppe; Piro, Agostino; Adduci, Carmen; Calò, Leonardo; Panchetti, Luca; Viani, Stefano; Rapacciuolo, Antonio; Sanna, Giampaolo; Molon, Giulio; Quartieri, Fabio; Di Rosa, Rita; Campari, Monica; Valsecchi, Sergio; D’Onofrio, Antonio title: A mobile app for improving the compliance with remote management of patients with cardiac implantable devices: a multicenter evaluation in clinical practice date: 2022-04-12 journal: J Interv Card Electrophysiol DOI: 10.1007/s10840-022-01207-y sha: 07048035510f86e56ff798a883f44bfd0a82de47 doc_id: 768984 cord_uid: xvw48xjt BACKGROUND: The remote device management (RM) is recommended for patients with cardiac implantable electronic devices (CIEDs). RM underutilization is frequently driven by the lack of correct system activation. The MyLATITUDE Patient App (Boston Scientific) has been developed to encourage patient compliance with RM by providing information on communicator setup, troubleshooting, and connection status of the communicator. METHODS: At 14 centers, patients with CIEDs were invited to download and install the App on a mobile device. After 3 months, patients were asked to complete an ad hoc questionnaire to evaluate their experience. RESULTS: The App was proposed to 242 consecutive patients: 81 before RM activation, and 161 during follow-up. The App was successfully installed by 177 (73%) patients. The time required for activation of the communicator and the need for additional support were similar between patients who followed the indications provided by the App and those who underwent standard in-clinic training. During follow-up, notifications of lack of connection were received by 20 (11%) patients and missed transmission by 22 (12%). The median time from notification to resolution was 2 days. After 3 months, 175 (99%) communicators of the 177 patients who installed the App were in “Monitored” status versus 113 (94%) of 120 patients without the App installed (p=0.033). The use of the app made 84% of patients feel reassured. CONCLUSIONS: The App was well accepted by CIED patients and offered support for communicator management and installation. Its use enabled patients to remain connected with greater continuity during follow-up. According to current guidelines, the use of remote management (RM) is recommended for patients with cardiac implantable electronic devices (CIEDs) [1, 2] . Several trials have compared in-person evaluations and RM for the follow-up care of CIED patients and have explored the ability of RM to detect problems early, thereby improving patient outcomes [3] [4] [5] [6] . The advent of wireless RM and novel diagnostic features that enable devices to monitor their own functions, record arrhythmias and physiological parameters, and automatically communicate this information to healthcare providers without the active participation of the patient has been critical to achieving the follow-up goals of patient adherence to structured follow-up protocols and to improving the workflow efficiency of device clinics [2, 7, 8] . Successful transmission of RM data by the patient to the healthcare provider relies on the enrollment of the patient in the specific RM system and the subsequent activation and maintenance of RM by the patient. Enrollment in RM has been shown to depend largely upon the local practice of the institution. However, RM activation and transmission by the patient depend upon patient factors [9] . The continuity of monitoring is crucial. Indeed, patients who consistently transmit data by means of RM are at substantially lower risk of death and readmission to hospital [10] . The MyLATITUDE™ Patient App (Boston Scientific) has been developed to encourage patients' compliance with RM by providing them with information on communicator setup and troubleshooting, connection status of the communicator, scheduled transmissions, and status of the battery of the implanted device. In the present study, we evaluated the first experience of the adoption of the MyLATITUDE™ Patient App in clinical practice. From May to July 2021, at 14 Italian arrhythmia centers, patients with a compatible Boston Scientific CIED with RM capabilities were invited to download and install the App on a mobile device. The use of the App was proposed to all consecutive patients after CIED implantation or, during a scheduled follow-up visit, to consecutive patients already enrolled and monitored at home through the LATITUDE™ platform. The study design was approved by the Institutional Committee on Human Research of each center and informed consent was obtained from all patients. According to individual patient preference, patients were assigned to the App group or the control group. In the App group, patients received instructions on how to download the App from the App Store of their own mobile device. The LATITUDE™ communicator was given to all patients before discharge or directly delivered to their homes, according to the standard practice of the center. Patients were invited to follow the indications provided by the App in order to activate the communicator and perform the first transmission. If they had any difficulties, patients could contact the center or the Boston Scientific customer support service. After activation, patients were instructed to follow the indications provided by the App in order to solve possible connection problems in the event of notification of "Not Monitored" status or missed scheduled remote transmission. The group of patients already monitored at home through the LATITUDE™ platform and invited to use the App were included in the analysis of the compliance with remote monitoring. An additional group of 60 consecutive patients served as control group and received standard inclinic training on the activation and use of the communicator, as well as the patients who did not install the App. In November, the monitoring status of all patients with a LATI-TUDE™ communicator was checked. Patients in "Monitored" status were considered compliant with remote monitoring at medium-term follow-up. All patients were asked to reply to an ad hoc questionnaire to collect anonymous data and evaluate their experience. All data were collected under local standard-of-care conditions of use. The operators at the centers were also asked to complete a questionnaire to provide their feedback on the adoption of the App. The App enables patients to independently obtain instructions and information on their communicator and CIED. It works with all Boston Scientific CIEDs that are monitored on the LATITUDE™ NXT platform and can be used by patients and/or their caregivers (Fig. 1) . The App is available for iOS and Android mobile phones; it does not connect directly to the patient's device but receives the data from the server. The App provides easy-to-follow steps that enable patients to set up their communicator. If the patient's communicator is not in a "Monitored" state, the App notifies the patient and provides resources to troubleshoot the problem, in order to encourage patient compliance with RM and to reduce the center's burden of managing "Not Monitored" patients. Moreover, the App informs patients of the status of scheduled remote transmission and of the CIED battery. Descriptive statistics are reported as means ± standard deviation for normally distributed continuous variables or medians with 25th to 75th percentiles in the case of skewed distribution. Categorical data were expressed as percentages. Differences between mean data were compared by means of a t-test for Gaussian variables and Mann-Whitney non-parametric test for non-Gaussian variables. Differences in proportions were compared by means of a chi-square analysis. A p-value <0.05 was considered significant for all tests. All statistical analyses were performed by means of R: a language and environment for statistical computing (R Foundation for Statistical Computing, Vienna, Austria). The MyLATITUDE™ Patient App was proposed to patients with a compatible CIED at 14 Italian arrhythmia centers. At 11 (79%) centers, the professionals routinely involved in remote device management were nurses and physicians, in accordance with a "Primary Nursing" model. In the remaining 3 (21%) centers, they were physicians alone. The communicator was delivered by nurses at 11 (79%) centers and by physicians at 3 (21%) centers. At 6 (43%) centers, home delivery of the communicator was allowed if preferred by the patient. The professionals involved in training patients in the activation and use of the communicator were nurses at 9 (64%) centers and physicians at 5 (36%) centers. The App was proposed to 242 patients: 81 consecutive patients immediately after CIED implantation and 161 patients who were already being monitored at home through the LATITUDE™ platform and who were consecutively enrolled at the time of an in-clinic visit. The App was successfully installed by 177 (73%) patients; 49 (20%) declined, 12 (5%) did not have a suitable mobile phone, and 4 (2%) experienced technical problems that precluded LATITUDE™ communicator activation (lack of landline and mobile telephone coverage). Baseline parameters of the study population are reported in Table 1 . Patients who installed the App were younger and had a higher level of education. The App was more frequently accepted by patients already using RM. The App was installed by 127 (72%) patients, by 39 (22%) caregivers, and by patient and caregiver in 11 (6%) cases. Installation problems that did not preclude final activation were reported by 15 (8%) patients. In 12 cases, troubleshooting required telephone support. Forty-eight patients successfully followed the indications provided by the App on how to activate the communicator and perform the first transmission. Standard post-implantation in-clinic training was received by the 33 new RM activation patients who did not install the App and by another 60 consecutive patients. Of these latter, one (2%) patient experienced technical problems that precluded communicator activation. The duration of in-clinic training was < 30 min for all patients. The App-guided installation group and the control groups (standard in-clinic training group and App-decliners) were similar in terms of the time required (Table 2) . Patient survey questions on the installation and activation procedure in the groups are reported in Table 2 . The level of satisfaction with the information received from the App during the installation procedure was comparable to that provided by in-person training. Of the 177 patients who installed the App, 20 (11%) received notifications of lack of connection during followup and 22 (12%) information of missed scheduled transmissions. The median time between notification of "Not monitored" status and resolution was 2 days (<1 week in 90%). After 3 months, 175 (99%) of these 177 communicators were in "Monitored" status. Of the 120 patients without the App installed, 113 (94%) were in "Monitored" status at the end of the observation (p=0.033). In particular, 48 (100%) of 48 patients who installed the App immediately after CIED implantation and 54 (92%) of 59 patients of the standard in-clinic training group (excluding App-decliners) were in "Monitored" status at the end of the observation (p=0.063). The continuous monitoring of the connection status during follow-up made patients feel reassured (Table 3) . Survey questions on operator experience with the App are reported in Table 4 . Most operators judged the App to be an effective and efficient tool. Nonetheless, in the opinion of those operators who were not inclined to extensively suggest the use of the App, the best targets are younger and more highly educated patients or those who can be supported by a caregiver. In the present study, we described the introduction into clinical practice of a mobile App designed to help CIED patients install and use an RM communicator and to provide notifications on the connection status of the device. The MyLATITUDE™ Patient App was accepted by a high proportion of CIED patients. Moreover, installation of the App was completed successfully in most patients. The App was more frequently installed by younger and more highly educated patients and especially by those who were already enrolled and monitored at home through the RM platform. Indeed, the implantation of a CIED constitutes a major change for the patient, who might need some time before trying to learn about RM and additional tools. Although in most cases the App was directly installed by the patients themselves, when a caregiver was available, it was installed by this latter. Indeed, the support of a caregiver can help to overcome the reluctance of older and less tech-savvy patients. Patients who installed the LATITUDE™ communicator under the guidance of the App did so just as successfully as those who had undergone standard post-implantation training of about 30 min in hospital; they had no additional problems, and installation time was similar. Moreover, the level of satisfaction with the App-guided installation was high, and, although approximately 30% of patients responded that they would have preferred in-person training, it is noteworthy that 20% of patients in the control group would have preferred more extensive training. The use of the App to activate the communicators is mainly intended as a potential advantage for the centers, which save the time usually devoted to in-person training and hopefully receive fewer requests for support, as patients can troubleshoot by using the App. In patients who enabled the App, we recorded notifications of missed transmissions or lack of connection Operator's comments: *: "the center's patients are mostly elderly and have greater difficulty in using the App"; **: "for elderly patients without caregiver support, it is more time-consuming" during follow-up. After notification, problems of connection were promptly solved by the patients. Consequently, these patients were able to remain connected with greater continuity than a similar group of patients who did not use the App, with a very high proportion of communicators regularly transmitting data at 3 months (99% versus 94%, p=0.033). This finding was obtained in the overall group of patients who installed the App and confirmed, although with no statistical significance (100% versus 92%, p=0.063), comparing patients who installed the App immediately after CIED implantation and patients of the standard in-clinic training group. This finding may have clinical implications. Indeed, previous analyses revealed not only better survival of patients enrolled in RM programs [11] , but also an association between RM and a lower risk of mortality and re-hospitalization in the real world. Specifically, one analysis showed that the adjusted hazard of mortality up to 3 years was significantly lower among patients on active RM at 90 days (HR 0.80, 95% CI 0.76-0.84) [10] . Barriers to the widespread use of RM can arise at the time of program implementation in the center and also owing to difficulties in activating RM and keeping patients monitored. While the implementation depends largely on the local practice environment and the institution, RM activation and transmission are more dependent on patient factors [9] . The adoption of the MyLATITUDE™ Patient App made patients feel reassured, seemed effective in helping them stay compliant with RM, and may possibly promote their engagement in their own healthcare. The remote management of CIEDs has been proposed as a strategy to improve the efficiency of device followup by replacing in-office device follow-up visits with remote transmissions [12] [13] [14] . Moreover, RM enables continuous assessment of device-related and clinical parameters, allowing early detection of device malfunction [15] [16] [17] or clinically relevant events [18] [19] [20] , thereby potentially improving clinical outcomes [11, 21, 22] . Thus, current guidelines suggest the routine use of RM [1, 2] , a recommendation that is even stronger in the era of the coronavirus disease 19 (COVID-19) pandemic, in order to maintain a high degree of safety and limit face-to-face interactions [23] [24] [25] [26] . According to a survey by the European Heart Rhythm Association, the main barriers to the adoption of remote monitoring are the lack of reimbursement and the increased workload [27] . Although the COVID-19 pandemic has caused an acceleration in the use of RM of CIEDs, and also the establishment of reimbursement codes in some European regions, the affordability of the model for the centers that decide to implement an RM service remains a critical issue [28, 29] . The adoption of tools like the MyLATITUDE™ Patient App may be an efficient way to ensure continuity of patient monitoring while maintaining under control the workload at the centers. This could be achieved by reducing the time spent on training and support for technical troubleshooting and on managing missed transmissions, which are known to impair the clinical efficiency of RM [30] . We recently implemented direct home delivery of the communicator and remote training of patients during the COVID-19 lockdown period in Italy [31] . This strategy proved feasible, enabling the RM of all previously unmonitored CIED patients, without requiring access to the hospital [32] . The MyLATITUDE™ Patient App could be effectively adopted to support that strategy, by enabling patients to activate their communicator even without traditional in-person training. As proposed by many RM programs, after CIED implantation, the implementation of RM could be deferred [2] . When patients are at home and have had the time to recover, accept the implanted device, and process the first CIED-related information, they may receive the communicator and proceed with installation by themselves, with the aid of the mobile App. Our findings have potential limitations. This was an observational non-randomized study. Some analyses were performed with patients self-selecting whether to be in the intervention or control group. Thus, a bias could affect our findings. As the project was limited to a single RM platform, our results may not be applicable to other systems. Moreover, we cannot exclude possible differences in the implementation of the initiative among centers, with an impact on the degree of success. The MyLATITUDE™ Patient App proved to be well accepted by CIED patients. It offered support for communicator installation and management and reassured patients. Its use allowed patients to remain connected with greater continuity during follow-up. ESC Guidelines on cardiac pacing and cardiac resynchronization therapy HRS Expert Consensus Statement on remote interrogation and monitoring for cardiovascular implantable electronic devices A randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial) Safety and efficiency of a common and simplified protocol for pacemaker and defibrillator surveillance based on remote monitoring only: a long-term randomized trial (RM-ALONE) Remote monitoring of implantable cardioverter-defibrillators Device monitoring of heart failure in cardiac resynchronization therapy device recipients: a single-center experience with a novel multivector impedance monitoring system Workload and usefulness of daily, centralized home monitoring for patients treated with CIEDs: results of the MoniC (Model Project Monitor Centre) prospective multicentre study Feasibility of automated detection of sleep apnea using implantable pacemakers and defibrillators: a comparison with simultaneous polysomnography recording Use of remote monitoring of newly implanted cardioverter-defibrillators: insights from the Patient Related Determinants of ICD Remote Monitoring (PREDICT RM) study Use of remote monitoring is associated with lower risk of adverse outcomes among patients with implanted cardiac defibrillators Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: the Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial Remote monitoring of implantable cardioverter defibrillator patients: a safe, time-saving, and cost-effective means for follow-up Cost-utility analysis of the EVOLVO study on remote monitoring for heart failure patients with implantable defibrillators: randomized controlled trial Semper Fidelis -Consumer protection for patients with implanted medical devices Deaths caused by the failure of Riata and Riata ST implantable cardioverterdefibrillator leads Sporadic high pacing and shock impedance on remote monitoring in hybrid implantable cardioverter-defibrillator systems: clinical impact and management Daily remote monitoring of implantable cardioverter-defibrillators: insights from the pooled patient-level data from three randomized controlled trials (IN-TIME, ECOST, TRUST) Multiparametric implantable cardioverter-defibrillator algorithm for heart failure risk stratification and management: an analysis in clinical practice Remote management of heart failure using implantable electronic devices Remote monitoring reduces healthcare use and improves quality of care in heart failure patients with implantable defibrillators: the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study A meta-analysis of remote monitoring of heart failure patients Guidance for cardiac electrophysiology during the COVID-19 pandemic from the Heart Rhythm Society COVID-19 Task Force; Electrophysiology Section of the American College of Cardiology; and the Electrocardiography and Arrhythmias Committee of the Council on Clinical Cardiology HRS/EHRA/APHRS/ LAHRS/ACC/AHA worldwide practice update for Telehealth and arrhythmia monitoring during and after a pandemic Impact of COVID-19 pandemic on cardiac electronic device management and role of remote monitoring Creating a safe workplace by universal testing of SARS-CoV-2 infection in asymptomatic patients and healthcare workers in the electrophysiology units: a multi-center experience Implementation and reimbursement of remote monitoring for cardiac implantable electronic devices in Europe: a survey from the health economics committee of the European Heart Rhythm Association Impact of COVID-19 pandemic on remote monitoring of cardiac implantable electronic devices in Italy: results of a survey promoted by AIAC (Italian Association of Arrhythmology and Cardiac Pacing) Impact of COVID-19 pandemic on the clinical activities related to arrhythmias and electrophysiology in Italy: results of a survey promoted by AIAC (Italian Association of Arrhythmology and Cardiac Pacing) Remote monitoring of cardiovascular devices: a time and activity analysis Management of cardiac implantable electronic device follow-up in COVID-19 pandemic: lessons learned during Italian lockdown Home delivery of the communicator for remote monitoring of cardiac implantable devices: a multicenter experience during the Covid-19 lockdown Ethics approval The study design was approved by the Institutional Committee on Human Research of each center. Competing interests M. Campari and S. Valsecchi are employees of Boston Scientific. The other authors report no conflicts.Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.