key: cord-0767759-tddvy5si authors: Wong, Y.‐P.; Othman, S.; Lau, Y.‐L.; Radu, S.; Chee, H.‐Y. title: Loop‐mediated isothermal amplification (LAMP): a versatile technique for detection of micro‐organisms date: 2018-02-12 journal: J Appl Microbiol DOI: 10.1111/jam.13647 sha: 99895776954fb65d8341f3f383e35e9951b4a798 doc_id: 767759 cord_uid: tddvy5si Loop‐mediated isothermal amplification (LAMP) amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions by using a DNA polymerase with high displacement strand activity and a set of specifically designed primers to amplify targeted DNA strands. Following its first discovery by Notomi et al. (2000 Nucleic Acids Res 28: E63), LAMP was further developed over the years which involved the combination of this technique with other molecular approaches, such as reverse transcription and multiplex amplification for the detection of infectious diseases caused by micro‐organisms in humans, livestock and plants. In this review, available types of LAMP techniques will be discussed together with their applications in detection of various micro‐organisms. Up to date, there are varieties of LAMP detection methods available including colorimetric and fluorescent detection, real‐time monitoring using turbidity metre and detection using lateral flow device which will also be highlighted in this review. Apart from that, commercialization of LAMP technique had also been reported such as lyophilized form of LAMP reagents kit and LAMP primer sets for detection of pathogenic micro‐organisms. On top of that, advantages and limitations of this molecular detection method are also described together with its future potential as a diagnostic method for infectious disease. Nucleic acid amplification is one of the most valued methods across all fields of science, from diagnosis of infectious diseases to application in biotechnology (Parida et al. 2008) . In addition to the widely used polymerase chain reaction (PCR)-based detection, numerous amplification techniques were designed (Guatelli et al. 1990 ). Examples of popular methods used are nucleic acid sequence-based amplification (Malek et al. 1994) , self-sustained sequence replication (3SR; Fahy et al. 1991) and strand displacement amplification (SDA; Walker et al. 1992) . Each of these methods has a different set of requirements to initiate DNA synthesis. For instance, PCR involves heat to denature the doublestranded target DNA into single-stranded to initiate DNA synthesis. SDA uses strand displacement action of exo-klenow to produce target DNA copies from 5 0 to 3 0 and the procedure occurs at a single temperature (Walker et al. 1992) . These methods are widely used in all fields of science to amplify the target sequence. However, they still suffer from insufficiencies and inadequacies. All these methods require a sophisticated instrument for amplification and detection or elaborate methods for performance (Fang et al. 2008) . As a result, researchers and scientists have worked hard to overcome these limitations. In the past decade, numerous isothermal amplification techniques were established. These include recombinase polymerase amplification, rolling circle amplification and helicase-dependent amplification (Zanoli and Spoto 2013) . Finally, Notomi et al. (2000) successfully devised a novel isothermal amplification method to amplify a limited amount of DNA copies into a million copies within an hour. This method is known as loop-mediated isothermal amplification (LAMP). LAMP is a novel molecular technique of nucleic acid amplification where a set of four (or six) different primers binds to six (or eight) different regions on the target gene making it highly specific (Notomi et al. 2000) . This primer set consists of two outer (F3 and B3) primers, two inner primers (forward inner primer (FIP) and backward inner primer (BIP)) and loop primers (loop forward and loop backward). LAMP reaction can be done simply at an isothermal condition by using Bst DNA polymerase which have high-displacement activity (Notomi et al. 2000) . An illustration on the LAMP primers binding sites and the amplification process is given in Fig. 1 . Since its development in Notomi et al. (2000) , LAMP has undergone numerous advancement in terms of its applications as a molecular amplification technique. In this section, different forms of LAMP assays including conventional LAMP, reverse-transcription LAMP, multiplex LAMP and a few other LAMP forms for detection of micro-organisms will be discussed in details. LAMP was successfully demonstrated to detect human respiratory pathogens, such as Mycobacterium tuberculosis Bentaleb et al. 2016; Nagai et al. 2016; Sethi et al. 2016; Sharma et al. 2016; Kaewphinit et al. 2017) , Streptococcus pneumoniae (Seki et al. 2005; Xia et al. 2014) , Bordetella pertussis (Fujino et al. 2015; Brotons et al. 2016; Kamachi et al. 2017) , and carbapenem-resistant Klebsiella pneumoniae (Nakano et al. 2015) . Furthermore, LAMP was also devised to diagnose pathogens associated with food-borne diseases, for instance, Salmonella typhi (Abdullah et al. 2014; Fan et al. 2015) , Campylobacter jejuni and Campylobacter coli (Pham et al. 2015) , and Helicobacter pylori (Bakhtiari et al. 2016; Yari et al. 2016 (Birmpa et al. 2015; Wang et al. 2015b; Ye et al. 2015) , Entamoeba histolytica (Rivera and Ong 2013; Singh et al. 2013; Mwendwa et al. 2017) , and human leptospirosis (Seesom et al. 2015; Hsu et al. 2017) . LAMP was also efficiently formulated against several multidrug-resistant Pseudomonas aeruginosa and Acinetobacter baumannii (Kim et al. 2016b ). The high LAMP assay usage proves its potential as a means for accurate molecular detection and to differentiate human pathogens. Recently, LAMP was used for the detection of a wide range of viruses. For example, adenovirus (Ziros et al. 2015) , varicella zoster (Kobayashi et al. 2014; Niihara et al. 2017 ) and cytomegalovirus (Wang et al. 2015a ). Hepatoviruses such as hepatitis B (Zhao et al. 2016) can also be detected using LAMP technique. The results showed that LAMP assay is promising for hepatitis diagnostics, donor screening, epidemiological studies and therapeutic monitoring of patients undergoing antiviral treatment. Protozoan parasites are equally harmful to humans and are one of the leading causes of death in the world. A parasitic disease detected by using LAMP was for malaria diagnosis of Plasmodium spp. (Britton et al. 2016; Lau et al. 2016; Zhang et al. 2017) . Poole et al. (2015) developed a highly sensitive LAMP for Loa loa detection, targeting the RF4 genes. The study reported that RF4specific LAMP can detect 1 microfilaria which is equivalent to 100 pg within 30 min. These studies provide examples of how LAMP can be implemented in field detection and early management of the parasitic infection (Poole et al. 2015) . A research was conducted by Nzelu et al. (2014) to detect Leishmania. In the study, they developed LAMP and tested it with 122 suspected clinical samples. The study showed that LAMP was efficient to detect 10 1 copies of DNA. They concluded that the newly developed LAMP was helpful when leishmania parasite density is very low, especially during the early infection stage (Nzelu et al. 2014 (Nzelu et al. , 2016 . There was a number of other reported significant practices of LAMP including Trichomonas viganalis (Reyes et al. 2014) , Necator americanus (Mugambi et al. 2015) and Strongyloides stercoralis (Watts et al. 2014) , and it was shown that LAMP is at least 1000 times more sensitive than the conventional PCR. The routine detection of fungi is laborious and expensive. A recent study was carried out to detect an extensive range of fungi, including Candida albicans, Cryptococcus neoformans and Mucor racemosus. The study reported the sensitivity of LAMP assay was 10 2 copies per 25 ll reaction. The assay can be efficiently used to detect fungi from the environment (Nakayama et al. 2017) . Another study was carried out by Luo et al. (2014) to detect aflatoxins by Aspergillus flavus, Aspergillus parasiticus and Aspergillus nomius. The study developed real-time LAMP to quantify A. flavus, A. parasiticus and A. nomius, and stated the detection limits of 10 1 , 10 2 and 10 3 , respectively, at 65°C within 60 min. The real-time LAMP assay established could be a promising assay for early diagnosis of Aspergillus infection in humans . Other successful examples of LAMP usage to detect fungal infections include Fonsecaea species (Sun et al. 2010) , Trichosporon asahii and Pneumocystis jirovecii (Nakashima et al. 2014; Singh et al. 2015) . LAMP requires minute quantities of DNA for detection of the fungal pathogen with unrivalled high sensitivity and easy handling. These qualities make LAMP suitable for all ranges of applications in the diagnosis of communicable diseases. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a one-step nucleic acid amplification technique used by taking a step further and adding LAMP with a reverse transcriptase enzyme to allow RNA detection (Notomi et al. 2000) . Like RT-PCR, RT-LAMP uses reverse transcriptase to make complementary DNA from RNA and is further amplified by using DNA polymerase. This method is valuable and beneficial because the assay can be completed in a single step, by incubating all the primers and enzymes (Bst polymerase and reverse transcriptase) with a constant temperature (Notomi et al. 2000 (Notomi et al. , 2015 Mori et al. 2013) , and this was very effective in detecting viruses with an RNA genome. RT-LAMP was established for Dengue virus (Hu et al. 2015; Lau et al. 2015) , influenza viruses (Nakauchi et al. 2014; Bao et al. 2015; Kim et al. 2016a Currently, one of the most successful uses of RT-LAMP is diagnosing the HIV retrovirus. RT-LAMP was developed to diagnose dormant HIV stage in infected individuals (Ocwieja et al. 2015; Odari et al. 2015) . A recent advancement was carried out by Damhorst et al. (2015) by incorporating a digital device with RT-LAMP to provide a smartphone-image of positive HIV-1 detection from whole blood. The assay showed sensitivity of 670 viruses per microlitre of whole blood. The digital RT-LAMP method could be used for the detection of viral load from a simple finger prick of blood from HIVpositive individuals in primary care amenities and clinical laboratory. The assay is functional for hospital-based infection control and for laboratory-based observations (Damhorst et al. 2015) . A recent study by Tian et al. (2016) also used RT-LAMP for the detection of synthetic zika virus (ZIKV) by targeting the NS5 gene. Although the study was only tested with synthetic ZIKV, it was one of a few studies that used a dual enzyme activity, Bst 3.0 polymerase which could amplify both DNA and RNA under the same conditions. The sensitivity of the assay was reported to be 1 attomolar (aM) synthetic ZIKV within 30 min. The study also reported no cross-reactivity with closely related Flaviviruses (Tian et al. 2016) . RT-LAMP was also used to detect plant pathogens. One of the recent examples of RT-LAMP plant pathogens detection is Apple chlorotic leaf spot virus (ACLSV), by targeting the virus coat protein gene. The reaction conditions were optimized according to temperature and reaction time. The RT-LAMP developed was capable to detect concentration as low as 0Á02 lg ll À1 at 64°C. The study reported that RT-LAMP has a 100-fold greater sensitivity as compared with RT-PCR (2Á29 lg ll À1 ). The assay could be successfully applied to field-collected apples to diagnose the diseases and to potentially control the spreading of ACLSV (Peng et al. 2017) . RT-LAMP was as well developed for animal pathogens, for example, Batai virus (BATV), a mosquito-borne virus, which would cause congenital defects in ruminants (cattle). Liu et al. (2016) developed and optimized RT-LAMP targeting the M gene of BATV. The time detection of BATV was reduced to 40 min, at 65°C, when RT-PCR would normally take hours. The results were simply and readily visualized with the naked eye on colour change. The assay reported a sensitivity of 2Á86 copies per ll, which is roughly 100 folds higher than qRT-PCR. Therefore, RT-LAMP showed a promising diagnostic tool for BATV detection, especially in the farm house . A novel RT-LAMP was developed by Chander et al. (2014) and it was the first study to report the application of novel polymerase, OmniAmp polymerase. The polymerase enzyme exhibited similar activity to that of Bst 3.0 polymerase that allows the direct detection of both DNA and RNA. RT-LAMP assays were developed for six RNA viruses. All targets were amplified within 30 min without extra steps or alteration of the reaction designs used for DNA targets. In comparison to the conventional Bst polymerase, OmniAmp polymerase was reported to be less inhibited by whole blood components, more rapid detection for diluted low viremia samples, more thermostable and perfect with a dry set-up that allows extended storage period at ambient temperature, thus it was more suitable for the development of lateral flow device and lyophilized LAMP. Considering the qualities, OmniAmp polymerase is more suitable to be used for molecular diagnostic in field setting (Chander et al. 2014) . Simultaneous detection of multiple target genes could enhance the specificity and reliability of a diagnosis method. This was applied in LAMP reaction as an advancement of the method, namely multiplex LAMP (mLAMP). Lau et al. (2015) developed RT-LAMP in a single tube coupled with mLAMP approach for detection of the dengue virus. This is one of the simplest mLAMP approach reported since identification of specific LAMP product was not needed. In this study, LAMP primer sets were specifically designed for each serotype of the dengue virus: DENV-1, DENV-2, DENV-3 and DENV-4 targeting on the 3 0 -noncoding region (NCR). Interestingly, all the primer sets were added together into a single tube of LAMP reaction to detect the presence of the dengue virus within 60 min of a LAMP reaction. The samples used in this reaction was the serum of dengue infected patients and healthy donors. Colorimetric detection was performed by using hydroxynaphthol blue (HNB), in which it allows the naked eye observation of final LAMP products. The sensitivity of this RT-mLAMP system was 10 RNA copies for all serotypes, and there was no crossreactivity with three closely related arboviruses observed (Lau et al. 2015) . Due to formation of multiple amplicons in the mLAMP products, this method needs to be coupled with several types of multiplex product detection method to specifically differentiate them. One of the example is combining mLAMP with dot enzyme-linked immunosorbent assay (dot-ELISA) for differential identification of Taenia solium, Taenia saginata and Taenia asiatica, where cytochrome c oxidase subunit 1 gene was chosen as the target (Nkouawa et al. 2016) . In this study, a single tube of mLAMP reaction was performed with FIP primers labelled with fluorescein isothiocyanate (FITC), digoxigenin (DIG) and tetramethylrhodamine (TAMRA), and BIP primers labelled with biotin. The mLAMP products from each plasmid containing the cox1 genes for T. solium, T. saginata and T. asiatica were captured by antibodies that were specific for FITC, DIG and TAMRA, respectively. Following this, Strep-Tactin alkaline phosphatase conjugate and chromogenic substrate was used to detect the mLAMP products. A positive result was indicated by purple dots developed on the membrane while uncoloured dots represented a negative result permitting the differential detection of these species. A study by Lee et al. (2010) reported the development of a one-tube reaction by using LAMP-PCR, hybridization, digestion with restriction endonuclease and colorimetric method of ELISA for the detection of M. tuberculosis that resistance to isoniazid, ethambutol and streptomycin. This was made possible by targeting hot spot point mutations in targeted drug-resistant genes: for isoniazid at katG 315 and katG 463, ethambutol at embB 306 and embB 497, and streptomycin at rpsL 43. In a reaction tube, LAMP primer sets targeting each of the mentioned point mutations and specific internal primers for PCR of individual resistance genes were added together with mycobacterial DNA template. The mixture was incubated at 65°C for 30 min to perform LAMP reaction followed by PCR assay by using LAMP products as the template. For differentiation of wild-type codons of resistance genes from mutant codon, specific restriction endonucleases were added to LAMP-PCR products where wild-type products were digested by specific restriction endonucleases. The digested products were then subjected to ELISA procedure where colour development and OD readings were recorded to indicate positive amplification for each target (Lee et al. 2010). A rapid LAMP and real-time monitoring procedure was combined for the simultaneous detection of foodborne disease pathogens, such as Salmonella spp. and Vibrio parahaemolyticus, as reported by Liu et al. (2017) . In a reaction tube, primer sets targeting these two species, respectively, were added and subjected to LAMP reaction for 60 min. However, LAMP selection caused by amplification bias was observed where Salmonella target sequence amplification rate is higher over that of V. parahaemolyticus. In order to overcome this issue, concentration of primer set detecting Salmonella was halved which resulted in equal amplification efficiency of both target sequence. After the isothermal amplification reaction, the products were subjected to a melting curve analysis and difference in melting temperatures (T m values) during the LAMP reaction was observed to distinguish these two pathogens . A novel mLAMP was developed by Stratakos et al. (2017) for detection and differentiation of nonpathogenic Escherichia coli and verocytotoxigenic E. coli (VTEC) in beef and bovine faeces. The mLAMP assay was designed for the detection of generic E. coli (nonpathogenic) targeting the phoA gene and VTEC strains targeting the stx1 or stx2 genes at 65°C for 30 min. In terms of the assay specificity, no cross-reactions were reported when 58 bacterial strains and specimens was used. Limit of detection for this assay was reported to be 10 3 -10 2 CFU per g, which may be adequate to be used for monitoring hygienic status of beef and to control food-borne diseases caused by VTEC (Stratakos et al. 2017) . The utility of mLAMP for detection of multiple genes for specific identification of parasites in mosquitoes was reported by Aonuma et al. (2010) . In this reaction, a mixture of LAMP primers for the detection of SPECT2 gene of Plasmodium berghei and cytochrome oxidase subunit I gene of Dirofilaria immitis was used. The FIP for each primer set was specifically labelled with FITC for P. berghei and cyanine5.5 (Cy5.5) for D. immitis. Real-time turbidity metre was used to monitor the amplification reaction and image analyser was used to examine the fluorescent dye-conjugated fragments. Green fluorescence signal produced by FITC indicated positive amplification of P. berghei, while for D. immitis, a magenta colour of Cy.55 was observed. This permitted the simultaneous detection of these two-parasitic species (Aonuma et al. 2010) . A study reported by Salinas and Little (2012) explains on the development of electric LAMP (eLAMP), an electronic simulation where it provides a fast and inexpensive putative tests of LAMP primers on target sequences compatibility. This method helps to improve the efficiency and aids to determine the opportunity of using existing primers to detect recently discovered sequence variants (Salinas and Little 2012) . In this study, sets of existing LAMP primers were tested using this eLAMP on 40 whole-genome sequences of Staphylococcus. The results correctly predicted that the tested primer sets would amplify from Staphylococcus aureus genomes and not from other Staphylococcus species. -Felipe et al. (2016) developed an assay for detection of pathogenic Salmonella spp. and identification of bovine meat in meat samples by using the principle of in-disc LAMP (iD-LAMP) and quantitative optical readout by a disc drive. iD-LAMP is an integrated device composed of micro-reactors embedded onto compact discs for real-time targeted DNA determination (Santiago-Felipe et al. 2016). Similar reagents used in conventional LAMP were used in this iD-LAMP except that it was performed in a micro-reactor placed in a 65°C oven. During the incubation, the disc was cyclically scanned and a sample was considered positive when the optical response was greater than the cut-off value. From this study, it shows that the result of iD-LAMP was comparable to those obtained by conventional LAMP with an extra advantage of using a smaller amount of template. Frequently used detection methods include turbidity, agarose gel electrophoresis, calorimetric detection using naked eyes and detection using UV light. Real-time monitoring based on turbidity using real-time turbidity metre (e.g. Loopamp Realtime Turbidimeter LA-200, LA-320, LA-500, Eiken Chemical Co., Ltd., Tokyo, Japan) is commonly used for LAMP product detection. LAMP assay was monitored for the white precipitation caused by the presence of magnesium pyrophosphate, Mg 2 P 2 O 7 (a by-product of LAMP reaction) at optical density 650 nm every 6 s. Several studies have been reported using turbidity to detect the presence of desired micro-organisms, for instances, Mycoplasma pneumoniae (Sakai et al. 2017) , Salmonella spp. (Mashooq et al. 2016) , human papillomavirus (Kumvongpin et al. 2016) and Clostridium difficile (Lin et al. 2015) . In case of unavailability of turbidimeter, a brief centrifugation of the LAMP products could be used as an alternative to observe the white precipitation, which is visible to naked eyes . Agarose gel electrophoresis could be used to visualize LAMP products as well. The end products of LAMP gene amplification will be stem-loop DNA structures with several inverted repeats of the target and cauliflower-like structures with multiple loops which cause the gel electrophoresis image of these products to be in ladder-like patterns. This method has been used for detection of E. histolytica . However, visualization of LAMP DNA product by gel electrophoresis required the opening of the reaction tubes, therefore increases the risk of carryover contamination, and application of gel electrophoresis is restricted due to the use of ethidium bromide stain, a highly hazardous chemical which is carcinogenic to human ). An alternative to gel electrophoresis, intercalating dyes were used for direct detection of the DNA products, for example, calcein, SYBR green I and HNB dye. Calcein dye, a metal ion binding fluorophore, which was added before isothermal incubation will form an insoluble salt complex, manganese-pyrophosphate (manganese ion, Mn 2+ from calcein whereas pyrophosphate is the by-product of LAMP reaction), thus making the reaction fluorescent. Subsequently, the fluorescence is further intensified when free calcein binds to magnesium ions (Mg 2+ from LAMP reaction mixture) and could be easily be observed under UV light (365 nm; Sahoo et al. 2016) . The reaction between Mg 2+ and calcein also causes the colour changes from orange to green, which could be observed via naked eyes under natural light. Positive LAMP reaction was indicated with green colour, whereas negative LAMP reaction indicated with orange colour. To name a few, calcein has been used in detection of Trypanosoma cruzi (Besuschio et al. 2017) , avian influenza H5 virus (Liu et al. 2013 ), hepatitis C virus (Zhao et al. 2017) , human papillomavirus , human coronavirus (Geng et al. 2016) and Flavobacterium columnare in tilapia fish (Suebsing et al. 2015) . Calcein-based end-point detection is most commonly used due to its high sensitivity and notable colour change for naked eye observation (Fischbach et al. 2015) . SYBR green I is also commonly used in LAMP assay. Addition of SYBR green I to reaction tubes containing LAMP products lead to visible colour change from reddish orange to yellowish green, and fluorescent under UV light. SYBR green I has been used for detection of coxsackievirus ( . Despite reported with good sensitivity, SYBR green I dye could inhibit LAMP reaction if the dye is added before isothermal incubation. Post-LAMP added dye required the opening of the LAMP tube which will leads to false-positive results due to aerosol contamination . HNB dye was commonly used as well for visualization of LAMP products. HNB dye changes from violet to sky blue colour and has been used for identification of Gram-negative bacilli (Srisrattakarn et al. 2017) , Chlamydia trachomatis (Choopara et al. 2016) , and M. tuberculosis (Balne et al. 2015) , orf virus in goat and cattle (Inoshima et al. 2017 ) and feline coronavirus (Stranieri et al. 2017) . Addition of HNB dye in LAMP reaction tube prior amplification could help to reduce aerosol contamination to the surrounding; however, HNB does not exhibit fluorescent ability, thus, only limited to naked colour changes observation (summarized end-point detection in Fig. 2) . Other dyes such as malachite green dye (Sriworarat et al. 2015; Lucchi et al. 2016; Nzelu et al. 2016) , Picogreen dye (Batra et al. 2015) , Gelred dye (Wozniakowski et al. 2013; Wassermann et al. 2014) , SYTO fluorescent dye (Liu et al. 2013; Watts et al. 2014; Mwendwa et al. 2017 2016), and Goldview II dye (Shi et al. 2011; Wu et al. 2014) were used as well for detection of LAMP DNA products. An alternative natural plant alkaloid dye known as berberine has been explored and used for detection of LAMP products. A study has been reported that berberine dye exhibit similar specificity and sensitivity compared with existing DNA intercalating dye and can be used as a fluorescent probe. Berberine dye is recommended for large field applications as it is cheaply available than other dyes (Fischbach et al. 2015) . Recently, more studies have been focused on developing lateral flow assay (LFA) for end-point detection of LAMP product. LFA is currently a favoured technique due to low-cost, user-friendly, simple, rapid, light and portable. The sample of interest, for example, saliva, blood, urine and other body fluids, is applied at one end of the strip (sample pad), which is conjugated with LAMP buffer mix and biotin, making the loaded sample suitable for interaction with the detection system. Most generally, lateral flow test was established using fluorescein in isothiocyanate (FITC) labelled DNA probes (which will recognize the specific region in the LAMP amplicon) hybridized with biotinylated LAMP amplicons (Thongkao et al. 2015; Fowler et al. 2016; Huang et al. 2017; Park et al. 2017 ). This complex would be captured by streptavidin on the biotin, forming another complex with anti-FITC antibody coated on the gold nanoparticles. This would give a visible result on the test line. However, the biotinylated nontargeted product would not hybridize with FITC DNA probe (only specific to LAMP amplicon), nor forming complexes with goldlabelled anti-FITC antibody to react with streptavidin on the test line, generating no signal thus a negative result on the test line. This complex would then move through the test line and was trapped at the control line (Chowdry et al. 2014; Yan et al. 2015; Nawattanapaiboon et al. 2016) . Successful LFA includes multiplex LFA-LAMP to simultaneously detect sea and seb gene of S. aureus Lateral flow biosensor (LFB) was successfully developed for multiplex detection of Enterococcus faecalis and S. aureus. The development of the LFB with gold nanoparticles had greatly helped in the visual detection of human pathogens without any instrumentation . Further advancement of LAMP end-point detection was made when Draz and Lu (2016) developed LAMP coupled with Surface Enhanced Raman spectroscopy (SERS) for rapid detection of Salmonella enteritidis. The study reported SERS detection labelling with Raman active gold nanoparticle was highly sensitive (100 times more than PCR), requires little sample preparation, and improves specificity and reliability by limiting false-positive results (Draz and Lu, 2016) . Moving towards the application of LAMP as a point-ofcare detection method, several advances have been reported to date including development of lyophilized form of LAMP reagents and commercially available LAMP kit for micro-organisms' specific detection. Lyophilized LAMP is a term used for the dried form of LAMP reagents, where it can withstand ambient temperature and long storage before being used for any molecular detection purpose hence the making of on-site diagnosis is possible. One of the examples on the utilization of lyophilized LAMP was reported by Hayashida et al., where they developed a single tube of dried LAMP reagent for diagnosis of human African trypanosomiasis on-site. By using this lyophilized LAMP reagents, the detection limit for detection of repetitive insertion mobile element (RIME), 18S rRNA and SRA-LAMP were 0Á01, 0Á1 and 1 parasite equivalent DNA per reaction, respectively. In terms of thermostability assessment, the lyophilized LAMP was incubated at 25 or 45°C for 72 h and used in comparison with fresh LAMP reagents for RIME-LAMP reaction, where the result was comparable (Hayashida et al. 2015) . The application of lyophilized LAMP reagents was reported by Chen et al. (2016) for the detection of Leptospira by using a LAMP primers combination targeting lipL32 and lipL41 genes. Bst DNA polymerase, dNTPs and primers were supplemented with sugars and subjected to lyophilization in a freeze-dryer. To evaluate the reagent stability and sensitivity, lyophilized LAMP reagents, which were stored at 4, 25 and 37°C, were used to test the detection limit alongside the freshly prepared LAMP reagents for Leptospira detection. The limit of detection observed for these two preparations were 12 copies of genomic DNA. In terms of stability, the results showed that lyophilized LAMP reagents retain the same reactivity as freshly prepared reagents and remain stable for up to 3 months when stored at 4°C . One of the latest development of the lyophilization method of RT-LAMP reaction was reported by Carter et al. (2017) with its application in the detection of Zaire Ebola Virus (ZEBOV). LAMP primers targeting L gene of ZEBOV were designed based on the alignment of isolates from 1976, 1995, 2007 and 2014 outbreaks as well as corresponding fragments were synthesized and cloned into plasmid which served as the template for in vitro transcription of the sense strand. The master mix was then subjected to cool in liquid nitrogen followed by freezedrying. In this study, they highlighted key modifications of the reaction components in order to maintain the lyophilized reagents stability, which was the addition of a nonreducing sugar trehalose and dialysis of the used enzyme preparations (Carter et al. 2017) . Several LAMP kits are commercially available in the market. For instance, the Loopamp TB detection kit, Trypanosoma brucei kit, L. monocytogenes detection kit, Legionella screening kit E for environmental detection, Malaria kit, SARS Coronavirus detection kit, Campylobacter detection kit, M. pneumoniae detection kit, E. coli O157 detection kit, Cryptosporidium detection kit, and Bovine Embryo Sex Typing Kit are all currently available from Eiken Chemical Co., Ltd. In 2010, another LAMP assay to detect C. difficile was developed by Meridian Bioscience USA, termed as illumigene â C. difficile. It was welcomed by many researchers due to its high sensitivity for detecting C. difficile (Pancholi et al. 2012) . LAMP primer sets are also commercially available from Eiken Chemical Co., Ltd, such as the Loopamp primer set for the West Nile virus; Avian flu H5 and H7; FluA influenza; Flavobacterium psychrophilum and Alicyclobacilus acidoterrestris. As suggested by WHO, the criteria for an ideal diagnostic test must comprise sensitivity, specificity, low-cost, simplicity, rapidity, adaptability to all kinds of climatic changes and the availability of instruments (Mabey et al. 2004) . Since detection of diseases is becoming progressively more difficult due to the occurrence of new as well as existing disease or pathogens, an alternative diagnostic method is in need to be discovered. Among the amplification techniques, LAMP stands out an effective diagnostic test. It is a preferred diagnostic tool, even though its principle and reaction mechanism is slightly complex (Notomi et al. 2015) . Ever since its development, the striking properties of LAMP have encouraged researchers to further explore its usage for analysis in various fields. As been discussed in this paper, LAMP could be one of the diagnostic method alternative in relation to its rapidity, sensitivity (Ishiguro et al. 2015; Kumvongpin et al. 2016; Besuschio et al. 2017 ) and specificity. The most significant advantage of LAMP would be its rapidity where LAMP allows immediate diagnosis. Unlike any other nucleic acid amplification technique, for example, PCR, LAMP could be performed in just 30 min rather than at least 90 min for PCR. In addition, a LAMP amplification proceeds rapidly since the initial heat denaturation for the DNA template is not required. Another advantage of LAMP would be its simplicity to be performed where all it needs is a simple water bath or heating block that provides an isothermal condition. This eliminates the need of advanced instruments as needed in other amplification technique. LAMP has the potential to improve molecular biology technology with the simplicity of the assay as it is much easier to use as compared with PCR. The simplicity of LAMP can also be described in the method of analysing the results. Direct evaluation of results were made possible whereby the dyes used in LAMP reactions enable naked eye observation of colorimetric changes be it under natural light or UV light with the use of fluorescence dye. Thus, unlike PCR, tedious gel electrophoresis procedure of the amplification products is not needed. Apart from that, a new pH sensitive dye for LAMP was recently developed by taking into consideration the unique features of Bst DNA polymerase in buffered solutions. Since a significant pH change from alkaline to acidic was observed during LAMP amplification, pH indicator dyes can be used to monitor the LAMP reaction and a significant colour change was easily visualized . This helps to further improve the flexibility of LAMP as a simple tool for use in endemic countries. LAMP assays also appeared unaffected by the presence of nontarget DNA in the acquired samples (Kaneko et al. 2007; Lin et al. 2012 ) which resembles its high specificity characteristic. The LAMP assay is stable against some PCR inhibitors such as blood and detection can be performed without the template extraction step and with a nonprocessed sample Francois et al. 2011; Lin et al. 2012; Mori et al. 2013; Wang et al. 2013) . As LAMP advances, it can be made into a portable device to ease transportation to the site of diagnosis, for example, the diagnosis of the Ebola virus and food-borne pathogens (Uddin et al. 2015; Kurosaki et al. 2016; Safavieh et al. 2016 ). On top of that, LAMP can amplify RNA with high efficiency by using reverse transcriptase (Mori et al. 2001; Nagamine et al. 2002; Dukes et al. 2006) . At present, improved DNA polymerases, such as Bst 3.0 polymerase and OmniAmp polymerase, are available for the application of LAMP and RT-LAMP. These DNA polymerases demonstrated a robust performance with increase reverse transcriptase activity as compared to conventional Bst DNA polymerase (Chander et al. 2014; Tian et al. 2016) . Despite the robustness of this novel technique, there are a few limitations that could impede its smooth application. This technique is inapplicable for cloning or other molecular biology purposes since the final product is a large DNA chain, making it to be less versatile when compared to PCR (Sahoo et al. 2016) . Furthermore, the multiplexing approaches of LAMP is still considered less successful than PCR as they increase the difficulty of the experimental design and procedures . It is also challenging to choose a correct and proper target for amplification, for either a highly conserved region or target site which is specific to a particular strain of micro-organism. Furthermore, in order to increase the sensitivity and specificity, LAMP uses 4-6 primers targeting 6 or 8 regions within a rather small segment of target sequence. Therefore, the primer design is exposed to many restrictions and it is problematic to design a LAMP primer. Even though a free online software is available to help with primer design, however, under certain circumstances, some of the preferred target sites might not be selected and, thus, would still rely on the need to manually design the primers. The usage of multiple primers will increase the chances of primer-primer hybridizations leading to template-free amplification, giving false-positive results (Watts et al. 2014 ), but the chances of false positivity require further investigation. In the case of the aforementioned phenomenon occurs, it is recommended to redesign the primers. One major drawback of LAMP is its high risk of carryover contamination which often leads to false-positive results in negative controls (Hsieh et al. 2014; Karthik et al. 2014 ). This is due to the extremely high efficiency of the LAMP reaction. The LAMP product is so stable that it is not degraded easily and thus unintended carryover contamination can occurs (Bi et al. 2012; Dhama et al. 2014; Fischbach et al. 2015) . In case aforesaid contamination occurs, it is suggested to perform LAMP in a laminar flow hood and use separate pipettes and filtered tips. For procedures that involved opening of the reaction tubes, for example, gel electrophoresis, it is wise to carry out LAMP in an isolated room as LAMP is highly sensitive to even minute amounts of product contamination. The turbidimetric and colorimetric determination of the LAMP reaction is subjective when determined by visual observation alone, as it relies on an individual's perception of colour (Bista et al. 2007) . Furthermore, the product of LAMP results in a ladder pattern or smearing on the gel rather than a single band as in PCR, thus identification of a target by size of the band on a gel is not possible with LAMP (Wastling et al. 2010) . The significant characteristics of LAMP are easy handling it only needs a simple water bath at a constant temperature and its rapidity. Developing a mobile biosensor with LAMP technology application may result in a significant advancement. To date, LAMP was widely used as a diagnostic tool for the detection of human, livestock and plant diseases. However, there are few publications on the use of this technique for the direct detection of environmental pathogens. The development of a sensor that can detect the presence of pathogenic pathogens directly from an environmental sample may bring vast benefits, especially in diseases that are caused by environmental pathogens, such as Leptospirosis. Apart from that, LAMP could also be applied in the early detection of genetic diseases in a foetus, for instance, Down syndrome and thalassemia, as it has high specificity. The development of microfluidic devices with LAMP also comes with many advantages, such as easy to operate, palm-sized, high output applicability, decrease in the consumption of expensive reagents and do not require electricity. LAMP microfluidic devices are commonly developed for food testing, cancer screening and virus detection. In summary, all of the features of LAMP prove that its straightforwardness is beneficial for the on-site field or diagnostics in an everyday basis in a POC setting. LAMP is a ground-breaking gene amplification technique. It works as a fast and simple diagnostic tool for the quick detection and identification of microbiological infections. Besides being simple to operate and easily adapted to any field circumstances and environments, LAMP has all the features required for real-time assays, especially in high sensitivity. LAMP is also a beneficial and valuable tool for use in developing countries due to its ease of performance without needing any advanced equipment or experts to operate it. In summary, LAMP could be the ideal diagnostic method, as it fulfils all criteria proposed by the WHO on ideal diagnostics. Grant Scheme by Ministry of Higher Education Malaysia (UPM/700-2/1/LRGS/5526400). Graduate student support for research works was provided by a Graduate Research Fellowship (GRF) from the Universiti Putra Malaysia and MyBrain15 from the Ministry of Higher Education Malaysia. Lee, M.F., Chen, Y.H., Hsu, H.J. and Peng, C.F. (2010) Onetube loop-mediated isothermal amplification combined with restriction endonuclease digestion and ELISA for colorimetric detection of resistance to isoniazid, ethambutol and streptomycin in Mycobacterium tuberculosis isolates. J Microbiol Methods 83, 53-58. Lee, D., Kim, E.J., Kilgore, P.E., Takahashi Rapid detection of Salmonella Typhi by loop-mediated isothermal amplification (LAMP) method Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis A single fluorescence-based LAMP reaction for identifying multiple parasites in mosquitoes Development and diagnostic evaluation of loop-mediated isothermal amplification using a new gene target for rapid detection of Helicobacter pylori Loop mediated isothermal amplification assay using hydroxy naphthol blue, conventional polymerase chain reaction and real-time PCR in the diagnosis of intraocular tuberculosis Rapid detection of subtype H10N8 influenza virus by one-step reverse transcription-loopmediated isothermal amplification methods Development and evaluation of loopmediated isothermal amplification assay for rapid detection of Capripoxvirus Development and evaluation of an in-house single step loop-mediated isothermal amplification (SS-LAMP) assay for the detection of Mycobacterium tuberculosis complex in sputum samples from Moroccan patients Analytical sensitivity and specificity of a loop-mediated isothermal amplification (LAMP) kit prototype for detection of Trypanosoma cruzi DNA in human blood samples A rapid loop-mediated isothermal amplification assay targeting hspX for the detection of Mycobacterium tuberculosis complex Evaluation of two loop-mediated isothermal amplification methods for the detection of Salmonella enteritidis and Listeria Monocytogenes in artificially contaminated ready-to-eat fresh produce Development of a loop-mediated isothermal amplification assay for rapid detection of BK virus A sensitive, colorimetric, highthroughput loop-mediated isothermal amplification assay for the detection of Plasmodium knowlesi Validation of a loop-mediated isothermal amplification assay for rapid diagnosis of pertussis infection in nasopharyngeal samples Lyophilized visually readable loopmediated isothermal reverse transcriptase nucleic acid amplification test for detection Ebola Zaire RNA A novel thermostable polymerase for RNA and DNA loopmediated isothermal amplification (LAMP) Highly sensitive loop-mediated isothermal amplification for the detection of Leptospira Development of lyophilized loop-mediated isothermal amplification reagents for the detection of Leptospira One-step reverse transcription loopmediated isothermal amplification for the detection of Maize chlorotic mottle virus in maize Identification of methicillin-resistant Staphylococcus aureus (MRSA) using simultaneous detection of mecA, nuc, and femB by loop-mediated isothermal amplification (LAMP) Rapid and visual Chlamydia trachomatis detection using loop-mediated isothermal amplification and hydroxynaphthal blue Rapid and specific detection of Asianand African-lineage Zika viruses Development of a loop-mediated isothermal amplification assay combined with a lateral flow dipstick for rapid and simple detection of classical swine fever virus in the field Smartphoneimaged HIV-1 reverse-transcription loop-mediated isothermal amplification Rapid and simple detection of Japanese encephalitis virus by reverse transcription loop-mediated isothermal amplification combined with a lateral flow dipstick Loop-mediated isothermal amplification of DNA (LAMP): a new diagnostic tool lights the world of diagnosis of animal and human pathogens: a review Development of a Loop Mediated Isothermal Amplification (LAMP) -Surface Enhanced Raman spectroscopy (SERS) Assay for the Detection of Novel reverse transcription loop-mediated isothermal amplification for rapid detection of foot-and-mouth disease virus Fast detection of Southern tomato virus by one-step transcription loop-mediated isothermal amplification (RT-LAMP) Self-sustained sequence replication (3SR): an isothermal transcriptionbased amplification system alternative to PCR The development and evaluation of a loop-mediated isothermal amplification method for the rapid detection of Salmonella enterica serovar Typhi Shining a light on LAMP assays -A comparison of LAMP visualization methods including the novel use of berberine Development of a reverse transcription loop-mediated isothermal amplification assay for the detection of vesicular stomatitis New Jersey virus: use of rapid molecular assays to differentiate between vesicular disease viruses Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications Loop-mediated isothermal amplification (LAMP) aids the clinical diagnosis of pertussis Visual detection of human coronavirus NL63 by reverse transcription loop-mediated isothermal amplification Isothermal, in vitro amplification of nucleic acids by a multienzyme reaction modeled after retroviral replication Direct blood dry LAMP: a rapid, stable, and easy diagnostic tool for Human African Trypanosomiasis Reverse-transcription loop-mediated isothermal amplification for rapid detection of respiratory syncytial virus directly from nasopharyngeal swabs Simultaneous elimination of carryover contamination and detection of DNA with uracil-DNAglycosylase-supplemented loop-mediated isothermal amplification (UDG-LAMP) Development and validation of a new loop-mediated isothermal amplification for detection of pathogenic Leptospira species in clinical materials Development of reversetranscription loop-mediated isothermal amplification assay for rapid detection and differentiation of dengue virus serotypes 1-4 The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Karlodinium veneficum Establishment of an on-site diagnostic procedure for detection of orf virus from oral lesions of Japanese serows (Capricornis crispus) by loop-mediated isothermal amplification Sensitivity and specificity of a loop-mediated isothermal amplification assay for the detection of Mycoplasma pneumoniae from nasopharyngeal swab samples compared with those of real-time PCR Development and evaluation of a loop-mediated isothermal amplification combined with au-nanoprobe assay for rapid detection of Mycobacterium tuberculosis Evaluation of a commercial loopmediated isothermal amplification assay for diagnosis of Bordetella pertussis infection Tolerance of loop-mediated isothermal amplification to a culture medium and biological substances New closed tube loop mediated isothermal amplification assay for prevention of product cross-contamination Rapid and sensitive detection of shrimp yellow head virus by loop-mediated isothermal amplification combined with a lateral flow dipstick Uracil-DNA glycosylase-treated reverse transcription loop-mediated isothermal amplification for rapid detection of avian influenza virus preventing carry-over contamination Rapid detection of Pseudomonas aeruginosa and Acinetobacter baumannii Harboring bla(VIM-2), bla(IMP-1) and bla(OXA-23) genes by using loop-mediated isothermal amplification methods Concurrent reactivation of herpes simplex and varicella zoster viruses confirmed by the loop-mediated isothermal amplification assay Loop-mediated isothermal amplification and LFD combination for detection of Plasmodium falciparum and Plasmodium vivax Loop-mediated isothermal amplification assay for rapid and sensitive diagnosis of tuberculosis High sensitivity, loop-mediated isothermal amplification combined with colorimetric goldnanoparticle probes for visual detection of high risk human papillomavirus genotypes 16 and 18 Development and evaluation of reverse transcription-loopmediated isothermal amplification (RT-LAMP) assay coupled with a portable device for rapid diagnosis of ebola virus disease in Guinea Rapid detection of Mycoplasma synoviae by loop-mediated isothermal amplification Use of reverse transcription loop-mediated isothermal amplification combined with lateral flow dipstick for an easy and rapid detection of Jembrana disease virus Colorimetric detection of dengue by single tube reverse-transcriptionloop-mediated isothermal amplification Loop-mediated isothermal amplification assay for identification of five human Plasmodium species in Malaysia Comparison of loop-mediated isothermal amplification (LAMP) and real-time PCR method targeting a 529-bp repeat element for diagnosis of toxoplasmosis Rapid detection of Macrobrachium rosenbergii nodavirus isolated in China by a reversetranscription loop-mediated isothermal amplification assay combined with a lateral flow dipstick method Rapid detection of ermB gene in Clostridium difficile by loop-mediated isothermal amplification Colorimetric detection of 23 human papillomavirus genotypes by loop-mediated isothermal amplification Establish and optimization of real-time fluorescent reverse transcription loop-mediated isothermal amplification for detection of avian influenza H5 hemagglutinin gene Development of reverse transcription loop-mediated isothermal amplification for rapid detection of batai virus in cattle and mosquitoes Development of a multiplex loopmediated isothermal amplification method for the simultaneous detection of Salmonella spp. and Vibrio parahaemolyticus Use of malachite green-loop mediated isothermal amplification for detection of Plasmodium spp. parasites Application of loop-mediated isothermal amplification assays for direct identification of pure cultures of Aspergillus flavus, A. nomius, and A. caelatus and for their rapid detection in shelled Brazil nuts Diagnostics for the developing world Nucleic acid sequence-based amplification (NASBA) Development and evaluation of probe based real time loop mediated isothermal amplification for Salmonella: a new tool for DNA quantification Evaluation of a rapid detection for Coxsackievirus B3 using one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation Loop-mediated isothermal amplification (LAMP): recent progress in research and development Development and evaluation of a loop mediated isothermal amplification (LAMP) technique for the detection of hookworm (Necator americanus) infection in fecal samples Stem loop-mediated isothermal amplification test: comparative analysis with classical LAMP and PCR in detection of Entamoeba histolytica in Kenya Rapid and simple identification of Beijing genotype strain of Mycobacterium tuberculosis using a loop-mediated isothermal amplification assay Loop-mediated isothermal amplification reaction using a nondenatured template Accelerated reaction by loop-mediated isothermal amplification using loop primers Rapid detection of the Klebsiella pneumoniae carbapenemase (KPC) gene by loop-mediated isothermal amplification (LAMP) Loop-mediated isothermal amplification method for diagnosing Pneumocystis pneumonia in HIV-uninfected immunocompromised patients with pulmonary infiltrates Development of a reverse transcription loop-mediated isothermal amplification assay for the rapid diagnosis of avian influenza A (H7N9) virus infection Detection of fungi from an indoor environment using loop-mediated isothermal amplification (LAMP) method Hemoculture and direct sputum detection of mecA-mediated methicillin-resistant Staphylococcus aureus by loop-mediated isothermal amplification in combination with a lateral-flow dipstick Rapid diagnosis of herpes zoster by loopmediated isothermal amplification in a pregnant woman showing folliculitis-like eruption without vesicles Simple identification of human Taenia species by multiplex loop-mediated isothermal amplification in combination with dot enzyme-linked immunosorbent assay Loopmediated isothermal amplification of DNA Loop-mediated isothermal amplification (LAMP): principle, features, and future prospects Development of multiplex loop mediated isothermal amplification (m-LAMP) label-based gold nanoparticles lateral flow dipstick biosensor for detection of pathogenic Leptospira A method for rapid detection and genotype identification of hepatitis C virus 1-6 by one-step reverse transcription loop-mediated isothermal amplification Development of a loop-mediated isothermal amplification method for rapid mass-screening of sand flies for Leishmania infection A rapid molecular diagnosis of cutaneous leishmaniasis by colorimetric malachite green-loop-mediated isothermal amplification (LAMP) combined with an FTA card as a direct sampling tool A reverse transcription loopmediated isothermal amplification assay optimized to detect multiple HIV subtypes Establishment and evaluation of a loop-mediated isothermal amplification (LAMP) assay for the semi-quantitative detection of HIV-1 group M virus Rapid detection of all known ebolavirus species by reverse transcription-loop-mediated isothermal amplification (RT-LAMP) Comparison of fluorescent intercalating dyes for quantitative loopmediated isothermal amplification (qLAMP) Detection of toxigenic Clostridium difficile: comparison of the cell culture neutralization, Xpert C. difficile, Xpert C. difficile/Epi, and Illumigene C. difficile assays Loop mediated isothermal amplification (LAMP): a new generation of innovative gene amplification technique; perspectives in clinical diagnosis of infectious diseases An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics One-step reverse transcription loopmediated isothermal amplification assay for detection of Apple chlorotic leaf spot virus Loop-mediated isothermal amplification (LAMP) for detection of Campylobacter jejuni and C. coli in Thai children with diarrhea Rapid and sensitive detection of Vibrio alginolyticus by loop-mediated isothermal amplification combined with a lateral flow dipstick targeted to the rpoX gene Genome filtering for new DNA biomarkers of Loa loa infection suitable for loopmediated isothermal amplification Development of a loop-mediated isothermal amplification assay for detection of Trichomonas vaginalis Development of loopmediated isothermal amplification for rapid detection of Entamoeba histolytica Emerging loop-mediated isothermal amplification-based microchip and microdevice technologies for nucleic acid detection Loop mediated isothermal amplification: an innovative gene amplification technique for animal diseases A novel detection procedure for mutations in the 23S rRNA gene of Mycoplasma pneumoniae with peptide nucleic acidmediated loop-mediated isothermal amplification assay Electric LAMP: virtual loop-mediated isothermal amplification Real-time loopmediated isothermal DNA amplification in compact disc micro-reactors Detection of pathogenic leptospires by loop-mediated isothermal amplification targeting LipL32 gene Loop-mediated isothermal amplification method targeting the lytA gene for detection of Streptococcus pneumoniae Loop-mediated isothermal amplification assay for detection of Mycobacterium tuberculosis complex in infertile women Diagnostic potential of multi-targeted LAMP (loop-mediated isothermal amplification) for osteoarticular tuberculosis Development and evaluation of reverse transcription-loopmediated isothermal amplification assay for rapid detection of enterovirus 71 groEL is a suitable genetic marker for detecting Vibrio parahaemolyticus by loop-mediated isothermal amplification assay Loopmediated isothermal amplification (LAMP) assay for rapid detection of Entamoeba histolytica in amoebic liver abscess Evaluation of loop-mediated isothermal amplification assay for the detection of Pneumocystis jirovecii in immunocompromised patients Evaluation of SYBR green I based visual loop-mediated isothermal amplification (LAMP) assay for genus and species-specific diagnosis of malaria in P. vivax and P. falciparum endemic regions Rapid and simple identification of carbapenemase genes, bla NDM, bla OXA-48, bla VIM, bla IMP-14 and bla KPC groups, in Gram-negative bacilli by in-house loop-mediated isothermal amplification with hydroxynaphthol blue dye Development of loop-mediated isothermal amplification (LAMP) for simple detection of Leishmania infection Reverse transcriptase loop-mediated isothermal amplification for the detection of feline coronavirus A loop-mediated isothermal amplification method for rapid direct detection and differentiation of nonpathogenic and verocytotoxigenic Escherichia coli in beef and bovine faeces Colorimetric method of loop-mediated isothermal amplification with the pre-addition of calcein for detecting Flavobacterium columnare and its assessment in Tilapia Farms Rapid detection of pathogenic fungi using loopmediated isothermal amplification, exemplified by Fonsecaea agents of chromoblastomycosis Visual detection of canine parvovirus based on loop-mediated isothermal amplification combined with enzyme-linked immunosorbent assay and with lateral flow dipstick Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes Rapid and sensitive detection of Vibrio harveyi by loop-mediated isothermal amplification combined with lateral flow dipstick targeted tovhhP2 gene Attomolar Zika virus oligonucleotide detection based on loop-mediated isothermal amplification and AC susceptometry A portable automatic endpoint detection system for amplicons of loop mediated isothermal amplification on microfluidic compact disk platform Strand displacement amplification-an isothermal, in vitro DNA amplification technique Real-time fluorescence loop mediated isothermal amplification for the detection of Acinetobacter baumannii Rapid detection of active human cytomegalovirus infection in pregnancy using loopmediated isothermal amplification The novel multiple inner primersloop-mediated isothermal amplification (MIP-LAMP) for rapid detection and differentiation of Listeria monocytogenes Rapid and sensitive detection of Zika virus by reverse transcription loop-mediated isothermal amplification Loop-mediated isothermal amplification labelbased gold nanoparticles lateral flow biosensor for detection of Enterococcus faecalis and Staphylococcus aureus A loop-mediated isothermal amplification (LAMP) method for the identification of species within the Echinococcus granulosus complex LAMP for human African trypanosomiasis: a comparative study of detection formats Preliminary validation of direct detection of foot-and-mouth disease virus within clinical samples using reverse transcription loop-mediated isothermal amplification coupled with a simple lateral flow device for detection A loop-mediated isothermal amplification (LAMP) assay for Strongyloides stercoralis in stool that uses a visual detection method with SYTO-82 fluorescent dye Comparison of loop-mediated isothermal amplification and PCR for the detection and differentiation of Marek's disease virus serotypes 1, 2, and 3 Development of double loop-mediated isothermal amplification to detect Listeria monocytogenes in food Rapid detection of Streptococcus pneumoniae by real-time fluorescence loopmediated isothermal amplification Development of a loop-mediated isothermal amplification assay for rapid detection of Nocardia salmonicida, the causative agent of nocardiosis in fish Rapid detection of measles virus using reverse transcription loopmediated isothermal amplification coupled with a disposable lateral flow device Rapid and visual detection of human enterovirus coxsackievirus A16 by reverse transcription loop-mediated isothermal amplification combined with lateral flow device Rapid and sensitive detection of Babesia bovis and Babesia bigemina by loop-mediated isothermal amplification combined with a lateral flow dipstick Loop-mediated isothermal amplification as a fast noninvasive method of Helicobacter pylori diagnosis Development of a real-time loopmediated isothermal amplification assay for the sensitive and rapid detection of Listeria monocytogenes Combined multiplex loop-mediated isothermal amplification with lateral flow assay to detect sea and seb genes of enterotoxic Staphylococcus aureus Application of loopmediated isothermal amplification assay combined with lateral flow dipstick for detection of Plasmodium falciparum and Plasmodium vivax Isothermal amplification methods for the detection of nucleic acids in microfluidic devices Development of loop-mediated isothermal amplification with Plasmodium falciparum unique genes for molecular diagnosis of human malaria Reverse transcription loop-mediated isothermal amplification assay for detecting tomato chlorosis virus Loopmediated isothermal amplification for visual detection of hepatitis B virus Detection of HCV genotypes 1b and 2a by a reverse transcription loopmediated isothermal amplification assay Establishment and application of a loop-mediated isothermal amplification (LAMP) system for detection of cry1Ac transgenic sugarcane Development and evaluation of a loop-mediated isothermal amplification assay for the detection of adenovirus 40 and 41 A special thanks to Lam Jia Yong for proofreading this manuscript. We also acknowledge Long Term Research No conflict of interest declared. All authors read and approved the final version of the manuscript.