key: cord-0766903-xpkwrwy9 authors: Park, Dae Hoon; Joe, Yun Haeng; Piri, Amin; An, Sanggwon; Hwang, Jungho title: Determination of Air Filter Anti-Viral Efficiency against an Airborne Infectious Virus date: 2020-04-12 journal: J Hazard Mater DOI: 10.1016/j.jhazmat.2020.122640 sha: 845c11e60e19b90e49a5f22d3c6764029c918c55 doc_id: 766903 cord_uid: xpkwrwy9 Abstract Recently, various studies have reported the prevention and treatment of respiratory infection outbreaks caused by lethal viruses. Consequently, a variety of air filters coated with antimicrobial agents have been developed to capture and inactivate virus particles in continuous airflow conditions. However, since aerosolized infectious viral-testing is inadvisable due to safety concerns, their anti-viral capability has only been tested by inserting the filters into liquid media, where infectious virus particles disperse. In this study a novel method of determining anti-viral performance of an air filter against airborne infectious viruses is presented. Initially, anti-viral air filter tests were conducted. Firstly, by an air-media test, in which the air filter was placed against an aerosolized non-infectious virus. Secondly, by a liquid-media test, in which the filter was inserted into a liquid medium containing a non-infectious virus. Subsequently, a correlation was established by comparing the susceptibility constants obtained between the two medium tests and an association was found for the air medium test with infectious virus. After ensuring the relationship did not depend on the virus species, the correlation was used to derive the results of the air-medium test from the results of the liquid-medium test. Biologically originated aerosols generally involve fungi, bacteria, and viruses and are defined as bioaerosols. In human environments, bioaerosol contaminants can cause adverse health impacts, such as allergic, infectious, and toxigenic diseases (1) (2) (3) (4) coated air filter against the bacteriophage MS2 virus through the process of dust loading. In all the aforementioned works, the bacteriophage MS2 virus was aerosolized using an atomizer or nebulizer, delivered to a filter by forced convection flow, and collected on the filter surface. The collected virus particles were then eluted from the filter surface to a liquid medium containing Escherichia coli strain C3000 (as the host of the bacteriophage MS2 virus) through physical vibration (sonication, vortex, and shaking) or elution with a urea-arginine phosphate buffer (U-APB) solution. Subsequently, plaque counting was performed, thereby enabling the evaluation of the effect of the NPs coated on the filter on the viability of the virus particle. Nonetheless, the test mentioned above (hereafter termed the air media test) may not be recommended for airborne infectious viruses due to the possibility of aerosol transmission (27-J o u r n a l P r e -p r o o f 29). In addition, because airborne virus particles move with airflow and can be captured by air filters used in indoor air cleaning, the data from the air media test are more practical and useful to people who need to use the air filters, such as healthcare workers (30, 31) . This paper presents a novel method of determining the anti-viral capability of an air filter against an airborne infectious virus. First, an Ag NP coated filter was inserted into a liquid medium in which infectious virus particles (H1N1) were dispersed. Then, the plaque counting method was conducted, hereafter termed the liquid media test. The results of the liquid media test were then converted to those of the air media test by using a correlation equation, which was established by comparing the susceptibility constants obtained from the two media tests with the selected non-infectious virus particles. Susceptibility has been used to explain the relative importance of various parameters affecting antimicrobial efficiency, such as the coating areal density of Ag NPs on the filter surface. Yoon et al. (32) used the susceptibility constant to evaluate the antibacterial effects of Ag and Cu NPs. The anti-viral air filters in this study were prepared by coating glass fiber high-efficiency particulate air (HEPA) filters (Fabriano, Italy) with Ag NPs. The HEPA filters of thickness 0.07 ± 0.004 cm, solidity 0.09 ± 0.004, and fiber diameter 2.7 ± 0.55 μm were used. Ag NPs were J o u r n a l P r e -p r o o f 6 synthesized using a lab-made spark discharge generation system. The details of the coating process have been presented in Joe et al. (26) . The size distribution of NPs was measured by scanning mobility particle sizer (SMPS), and the range of the NP coating areal densities used was 1.1 × 10 10 -1.4 × 10 11 particles cm −2 of the filter. To confirm the evolution and composition of the Ag NPs on the filter fibers, field emission scanning electron microscope-energy dispersive X-ray (FESEM-EDX; JSM-7610F-Plus, JEOL, Japan) analyses were performed. In this study, Escherichia coli bacteriophage T1 (ATCC 11303-B1), T4 bacteriophage (ATCC 11303-B4), and MS2 bacteriophage (ATCC 15597-B1) were used as the non-infectious virus species. These viruses were selected because they are relatively safe to handle in a biosafety level (BSL) I laboratory. These bacteriophages have been used in previous research works as surrogates for human and animal respiratory viruses (33) (34) (35) and in stringent test cases to evaluate the efficacy of antimicrobial agents (36, 37) . Each virus solution was prepared using 0.1 mL of virus stock defrosted at room temperature and poured into 50 mL of deionized (DI) water. To measure the bacteriophage concentration of the stock, a plaque assay was used (initial Cabinet (Type A1, KUMKANGENG Inc., Korea) in a BSL II laboratory. As shown in Fig where represents the airflow rate (L min −1 ) and represents the filter sample surface area (cm 2 ). The number of virus particles deposited onto the filter per unit volume of air passing through the filter was calculated as ( − ). The selected deposition time (τ) was 10 min. After the aerosolized virus particles were deposited onto the air filter sample, the filter sample was placed in an incubator. The air temperature and relative humidity inside the incubator were maintained at 25°C and 50%, respectively (Step 2). Following overnight incubation, each filter was submerged in 1 mL of RNase-free U-APB solution, which was prepared by adding 0. where indicates the concentration of virus particles and the subscript 0 indicates the pristine filter. The test results were then compared with the theoretical predictions about the overall anti-viral efficiency, as determined per the following equation: The fraction of surviving virus particles ( , ) during the time interval was defined by Joe et al. (26) . The filter sample detachment efficiency ( ℎ ) for the deposited virus particles was approximately 30% (Fig. S1) . Additional anti-viral effects from the released materials (such as Ag NPs and/or Ag ions) during the elution process were negligible (Fig. S2) . The experimental steps ( Fig. 1) were repeated with varying areal densities of Ag NP coating onto the filter sample. Regarding the liquid media test, an air filter sample, which contained non-infectious virus particles, was obtained using the procedure presented in Section 2.3. Therefore, the total , and the number of plaques, , is expressed as: where represents a constant dependent on the virus particle species. The concentration of virus particles on the filter sample in the liquid media ( ) was calculated according to the following equation: The value of was adjusted to equal that of by controlling for . The experimental steps used to evaluate the anti-viral capability of the filter in the liquid media are illustrated in Fig. 2 . This test used a virus solution that was diluted with DI water (10 8 PFU mL −1 for MS2, T1, and T4 bacteriophages). First, a circular filter sample of 1 cm in diameter was placed into the solution (Step 1). Then, the solution was incubated and shook at 37°C for 24 h (Step 2). Afterward, the solution was continually diluted with DI water to acquire a countable number of plaques, and the number of virus particles was then evaluated using the single agar layer method (Step 3). After overnight incubation at 37°C (Step 4), the number of plaques was counted (Step 5). Finally, the overall anti-viral efficiency was calculated using Equation 2. The experimental steps shown in Fig. 2 were repeated with various areal densities of the Ag NP coating on the filter sample. Figure 3 illustrates the experimental steps undertaken to evaluate the anti-viral capacity of the filter. The liquid media test was conducted with H1N1, using a virus solution that was diluted with DI water to a concentration of 10 6 PFU mL −1 . Similar to a previously reported procedure, a filter sample was cut into a 1-cm diameter circular shape and placed into the J o u r n a l P r e -p r o o f 13 solution (Step 1). Then, the solution was incubated and shook at 37°C for 24 h (Step 2). Next, the live H1N1 viruses were quantified using an RNA amplifying method. The reverse transcriptionpolymerase chain reaction (RT-PCR) system (12675885, Thermo Scientific™ PikoReal™, UK) was used to amplify the RNA of the virus (Step 3) . Finally, the overall anti-viral efficiency was determined according to the cycle number obtained from the PCR analysis, as follows: where indicates the cycle number for the Ag NP coated filter and 0 represents the cycle number for the pristine filter (Step 4). The experiments were repeated with various areal densities of the Ag NP coating. To demonstrate the validity of the correlation for infectious viruses, additional air media tests with infectious virus H1N1 were carefully performed in a BSL II laboratory while upholding BSL III precautions (Fig. S4) . (41). The high oxidation rate of NPs on the glass fibers was observed in EDX data (in Fig. 4) , indicating that the ambient clean air used in the coating process would oxidize the resulting particles. The size distributions of non-infectious viruses are shown in Figure S5a , b, and c. The GMDs of the aerosolized virus particles for MS2, T1, and T4 were 19.8, 23.1, and 24.6 nm, respectively. The GSDs were 1.74-1.93. In each case, the filtration efficiency of the air filter was more than 99.99%. Figure 5 shows the air media test results for ̅ (see Equation 2) with various Ag NP coating areal densities, in which the MS2 bacteriophage was used. In addition, Figure 5 shows the liquid media test results for ̅ with various NP coating areal densities. Because Γ = = , Equation 3 was also applied to the liquid media test. The value of ̅ for each media test increased and became saturated as the areal density of the coating increased. Notably, the ̅ for the liquid media test was lower than the ̅ for the air media test, implying that < . In other words, the virus particles are more susceptible to Ag NPs in air media than in liquid media. One plausible reason for this could be that in the air media test, many of the virus particles may have directly contacted the Ag NPs after being deposited and fixed onto the surface of the filter. On the contrary, in the liquid media test, virus particles could move freely in the liquid, enabling many virus particles to avoid contact with the Ag NPs. Specifically, the chances for virus particles to interact with Ag NPs were higher in the air media than in the liquid media tests. In the work of Yoon et al. (32) , the susceptibility constant ( ) for estimating antimicrobial activities of the NPs was suggested as follows: where is the concentration of NPs (μg mL −1 ) and ( 0 ) ⁄ is the survival fraction of the microorganism. In this study, the following equation was applied to assess the anti-viral capability of the filter against a non-infectious virus species: The experimental results for 0 ⁄ (survival fraction), as shown in Figure 5 , are replotted in Figure 6 . In Figure 6 , curve fits were attained by substituting the experimentally The susceptibility constants, and , were 3.94 × 10 −11 and 2.00 × 10 −10 cm 2 particles −1 , respectively. As anticipated, the susceptibility constant of the air media test was higher than that of the liquid media test. An explicit correlation was found between the two susceptibility constants, expressed as follows: found to be 0.2 and 0.198, respectively (Fig. S3) . Although the three virus types had different sizes, the values of β were similar at approximately 0.2 (Fig. S3) . The liquid media test was performed with the infectious virus H1N1. After converting the results of the liquid media test to those of the air media test by using the correlation equation, we were able to evaluate the effect of the Ag NPs on the infectious virus. The survival fraction of the H1N1 virus is shown in Figure 7 . The susceptibility constant of the liquid media test, , was 6.96 × 10 −11 cm 2 particles −1 , which resulted in an air media test susceptibility constant ( ) of 3.48 × 10 −10 cm 2 particles −1 . This implied that its anti-viral effectiveness could be underestimated in the liquid media test in comparison with the air media test. Interestingly, the estimated susceptibility constant and survival fraction from the proposed correlation matched with the experimental data with aerosolized H1N1 particles, which J o u r n a l P r e -p r o o f 18 had a GMD of 39.6 nm in diameter and a GSD of 1.76 (Fig. S5d) . Thus, it was confirmed that the results obtained from non-infectious virus experiments could be applied to those of the infectious virus (Fig. 7) . This study demonstrated an efficient and reasonable method to determine the anti-viral efficiency of an air filter against an airborne infectious virus without directly testing with an aerosolized infectious virus. In conclusion, our method determined two major filter operation characteristics: (1) administration. The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. Bioaerosol health effects and exposure assessment: progress and prospects Preparation of airborne Ag/CNT hybrid nanoparticles using an aerosol process and their application to antimicrobial air filtration Electrochemical carbon-nanotube filter performance toward virus removal and inactivation in the presence of natural organic matter N-halaminemodified antimicrobial polypropylene nonwoven fabrics for use against airborne bacteria Guideline for isolation precautions: preventing transmission of infectious agents in healthcare settings Occupational Safety and Health Administration. Pandemic influenza preparedness and response guidance for healthcare workers and healthcare employers. US Department of Labor Publication OSHA 3328-05 Susceptibility constants of Escherichia coli and Bacillus subtilis to silver and copper nanoparticles Establishing surrogate-virus relationships for ozone disinfection of wastewater T4 bacteriophage conjugated magnetic particles for E. coli capturing: Influence of bacteriophage loading, temperature and tryptone Aerosolization of Ebola virus surrogates in wastewater systems Differentiating between physical and viable penetrations when challenging respirator filters with bioaerosols SWNT− MWNT hybrid filter attains high viral removal and bacterial inactivation Highly Sensitive in Vitro Diagnostic System of Pandemic Influenza A (H1N1) Virus Infection with Specific MicroRNA as a Biomarker Airborne virus capture and inactivation by an electrostatic particle collector USEPA Manual of Methods for Virology United States Environmental Protection Agency