key: cord-0760074-84h3looj authors: Ijaz, M. K.; Karim, Y. G.; Sattar, S. A.; Johnson-Lussenburg, C. M. title: Development of methods to study the survival of airborne viruses date: 1987-11-30 journal: Journal of Virological Methods DOI: 10.1016/0166-0934(87)90114-5 sha: 3ae24898796b7972372f6ed11be3d07c44e8cfd5 doc_id: 760074 cord_uid: 84h3looj Abstract A number of viruses have been shown to be transmitted by the airborne route. It is the ability of these viruses to retain their infectivity for living hosts which play a key role in their aerial dissemination. Data generated by a number of workers on the airborne survival of viruses varies considerably because laboratory techniques have not been standardized. About 5 yr ago we started studies on the airborne survival of a number of animal and human viruses. This paper describes the methodology developed to study the aerobiology of these viruses. These methods should be useful in the aerobiological work of other viruses. The concept of airborne transmission of microbial agents is an ancient one, but the studies related to airborne transmission of microbes started during the past 5 decades (Ijaz and Sattar, 1987) . It is now well established that a variety of infectious agents, including many types of viruses, are able to spread by the airborne route. It is the capacity of these viruses to survive in the airborne state which results in their aerial dissemination. In view of this, a great deal of work has been conducted to determine which factor(s) promote or retard the survival of infectious viral agents in air (Spendlove and Fannin, 1982, Ijaz, 1985) . A review of the literature revealed a considerable variation in the results of different worhcrs because the laboratory techniques for viral aerobiological work have not been standardized. It has been noted that variations in techniques that may influence the results include: (1) methods of aerosol generation. storage. and sampling procedure. (2) methods of virus assay. (3) differentiation of total, physical and viability decay. (4) methods and extent to which relative humidity and temperature arc controlled. and (5) method of data presentation (Harper, 1963) . About 5 yr ago we started studies on the survival of a number of airborne human and animal viruses (Ijaz et al.. 1084. lY8S a,b,c; Sattar et al.. lY84; Karim et al.. 19%) . The purpose of this paper is to outline the basic techniques developed to study airborne viruses. These methods should be useful to study the aerobioogy of other viruses. The MA-104 cell line was used throughout this study for the cultivation and quantitation of rota-and polioviruses. A seed culture of these cells was originally received by us through the courtesy of Dr. H. Malherbe (Gull Labs, Salt Lake City* UT). The procedures for the cultivation, maintenance and passage of these cells have been described in detail previously (Ramia and Sattar, lY79) . For the growth and quantitation of human coronavirus 229E(HCV/229E). L-132 cells, a continuous line of human lung cells was used throughout this study. A seed culture of these cells was originally obtained from D.A. McLeod. Laboratory Center for Disease Control, Ottawa. Canada. They were routinely propagated as described previously (Kennedy and Johnson-Lussenburg, 1975176) . A-S-HeLa cells were used for the cultivation and quantitation of rhinovirus type 14 . These cells were obtained from Dr. K. Lonberg-Holm (E.I. duPont de Nemours and Co.. Central Research and Development Department. Wilmington DE). Both the cell growth medium and the split ratio were the same for the A-S-HeLa cells as they were for the L-123 cells. Simian rotavirus was also kindly supplied to us by Dr. Malherbe. A cell culture-adapted human rotavirus (subgroup 2, strain Wa) was a gift sent to us by Dr. R. Wyatt (Wyatt et al.. 1980) concentrated by ultracentrifugation at 100000 x g for 120 min. The pellet was resuspended in a 40% (w/v) solution of cesium chloride (CsCl) and layered onto a 55% solution of CsCl and then subjected to isopcynic banding by centrifugation at 100000 x g for 20 h. The fractions were collected from the bottom of the centrifuge tube and their refractive index measured. Those fractions with the density of 1.36 -1.38 g/ml were pooled together and dialyzed against distilled water overnight at 4°C. The dialyzed virus was resuspended in TPB and stored at -80°C. After collection of the virus-containing sample, the procedure for the quantitation of rotavirus alone or in mixed aerosol with poliovirus type 1 was applied. which was been described in detail previously (Sattar et al., 1984; Ijaz et al.. 198Sa) . Briefly, the cell monolayers were washed with several changes of EBSS to remove as much as possible the FCS that was present in the growth medium. Each well then received 0.1 ml of an appropriately diluted inoculum. For virus adsorption. the inoculated plates were kept for 1 h at 37°C on a pitched orbital shaker (Heidolph, F.R.G.). At the end of the incubation period, each monolayer was overlaid with 2.0 ml of a medium containing MEM. 0.6% Agarose Type 11 (Sigma Chemicals Co., St. Louis, MO) and 5.0 kg/ml of trypsin (ICN Nutritional Biochem., Cleveland. OH). The plates were resealed in plastic bags and incubated at 37°C for 3 days in a walk-in incubator. The procedure for fixation and staining of the monolayer before counting pfaques has been described earlier (Ramia and Sattar, 1979) . Plaque assays of HCV 229E were performed by standard method in monolayers of L-132 cells in 75 cm' disposable culture flasks (Lux, Scientific CJtrrp.). as previously described (Kennedy and Johnson-Lussenburg, 1975176) . The procedure for the quantitation of RV-14 is briefly as following. Flasks containing confluent monolayers of A-5HeLa cells were infected with 0.33 ml of the virus sample to be plaque assayed. The virus vvas adsorbed for 1 h at 33°C during which time the flasks were gently shaken at 20-min. intervals to distribute the inoculum over the monolayer evenly. At the end of l-h incubation period, the monolayers were overlaid with a medium containing 25 ml per tlask of M-199 (Flow Laboratories): 0.22% NaHCO,. ~-br~m~~deoxyilridine (BURR, Calbiochem) 100 wg!ml. DEAE-dextran 50 p@mI (Sigma). 30 mM MgCI? (Fisher Certified Reagent) and 0.9% oxoid No. I (Toxoid). The flasks were then piaced in a CQ incubator at 33 "C. The plaques of RV-14 were ready within '72 h of incubation at which time the cells were mixed with 5 ml of a 4% form01 saline solution and allowed to stand for 24 h at room temperature to get rid of all infectious virus. The agar ovferlay was then carefully removed and the remaining fixed monolayer was stained with a 1% solution of crystal violet to enhance the visibility of plaques which were then counted. Virus titers were expressed as plaque forming units per ml (PFUlml). Virus-containing aerosols were generated using a &jet Colhson nebulizer as modified from the 3-jet Coil&on as described by May (1973) and purchased from BGI Inc., Waltham, MA. The property of this nebulizer is that it produces aerosols with an aerodynamic size of fess than 5 km which are of significance for their stability in airborne state and subsequently are capable of being retained in the respiratory tract of the host upon inhalation. After suspending the virus in the appropriate medium it was aerosolized using a h-jet Cohison nebulizer (May. 1973 ) purchased from BGI Inc.. Waltham, MA. A 300-I stainless steel drum (Goldberg et al.. 195X: Mitchell et al., 1968) was used for the storage of the aerosols (Fig. 1) . The drum was rotated at 4 rpm to reduce the toss of the aerosols by sodimentation (Goldberg et al.. 19%) . The temperature inside the drum was kept at 20 ~ti"C, The drum air containing the virus aerosol was sampled at appropriate intervals using an All Glass Impinger (Tyler and Shipe. f959). A critical vacuum was maintained in all experiments so that the impinger would operate at its design capacity of 5.6 limin. After each experiment the drum was thoroughly flushed with room air to remove all the virus and dye left from the experiment. All relative humidity (RH) measurements were made with the help of a dial type hygrometer (Airguide Instruments Co.. Chicago. IL,) affixed to the drum. The procedures for achieving the desired RH level in the drum have been described earlier (Sattar et al.. 1984; ljaz et al. I98Sa) . Experiments were carried out at the following three RH levels: low (3Ort5%), medium (50+5%) and high (8025%). For the experiments at low RH, the drum was first filled with air passed through a Drierite cylinder (Hammond Drierite Co.. Xenia, OH). When experiments were carried out at medium and high RH level, distilled water was sprayed into the drum to raise the RH to the desired level and then the virus aerosolization was carried out. The ideal tracer would be radiolabelled virus which permit each virion to act as a self-tracer. The use of radiolabelled virus is not only expensive but could be hazardous. So the feasibility of using fluorescent dyes was considered and thus a comparative study was made with radiolabelled virus. Either Rhodamine B (Songer, 1967; Elazhary and Derbyshire, 1977) or uranine (Beard and Easterday, 1965; Ijaz et al., 1985a) were used as the physical tracer in this study. Reference solutions for the standardization of the dye were prepared in TPB. An Aminco-Bowman spectrophotofluorometer (Ame~can Instrument Co., Silver Springs, MD) was used for measuring the dye concentr~~ti~~n in the samples. The excitation and emission wavelengths used were 546 and 590 nm for rhodamine and for uranine 493.5 and 512.0 nm, respectively. All the readings were taken at room temperature. In order to determine the suitability of the dye as a physical tracer. initial comparative tests were run using "Se-1abelled virus. The yuantitv of the radio-labelled virus was measured using a scintillation counter (Model LS 250, Beckman Instrument Inc.. CA). of size of the viral arrosois The distribution of virus aerosol in the drum air was determined at three RI-1 levels using an Anderson sampler (Anderson, 1958) . The same sampler was used throughout the experiments. This sampler is designed in such a way that it separates the aerosols according to their aerodynamic size. As rec~~mmended by Anderson (19%). each Petri dish contained 27 ml of collecting medium. The collecting medium in the Petri dishes was modified from Guerin and Mitchell (1964) . A 10% solution of gelatin (Fisher Scientific Ltd.. Canada) was prepared in sterile distilled water and heated at 100°C for about 30 min. Pre-sterilized TPB was kept at 37°C and gelatin solution was added to give a final concentration of 3%. These plates were placed at 4°C until used. Before each sampling, the Petri dishes containing the TPB and gelatin to a final concentration of 3% were loaded onto the stages of the sampler and the sampler was operated for I min to draw 2X limin of drum air onto the surface of the medium (Anderson. 19%). When '%e-labelled virus was to be nebuhzcd. it was suspended in TPB alone. However. the spray fluid for the unfabelled virus also contained 2.5 mgiml of Rhodamine and Antifoam C (Sigma) at a final concentration of 1%. The Collison nebulizer, with 15 ml of the appropriate spray fluid. was attached to the inlet of the rotating drum and aerosolization was carried out at a pressure of 1 .X kg/cm'. The first air sample from the drum was collected after a 15 min period of aerosol stabilization. An impinger, containing 10.0 ml of either MEM or TPB with 1% antifoam as aerosol collection fluid, was operated for 1 min. to draw 5.6 1 of the drum air. Using the same procedure, additional samples of air were collected 0.5. 1. 2, 4, 8, 24, 48 and 72 h after virus aerosolization. The fluid from the impinger was divided into two portions. One of these was used for estin~ating the arn~~ur7t of the physical tracer and the other for the determination of the virus by plaque assay. The extent of biological decay of the virus was calculated using the following formula: When II,, and D, are the dye concentration at times 0 and t h, respectively. sinilarly V,, and V,. are the virus titers at 0 and I h, respectively. It should be noted that time 0 is taken at the end of the IS min equilibration period in the drum. The difference between the input virus concentration and the 15 min sample concen-tration expressed as a percent represents the 'initial loss' due to the process of generating the virus cloud. Survival of the aerosolized virus was tested at three levels of RH: low (30 5 5%), medium (50 t 5%) and high (80 5 5%). The survival of the aerosolized virus under various experimental conditions was plotted against time using an exponential model: and the coefficients A and B were estimated by least squares curve fitting. At least three experiments at each RH and temperature were carried out and the half-lives of the viruses were calculated by regression analysis (Lawless. 1982) . In order to be able to compare the data generated on the airborne survival of the various types of viruses tested, it was essential to keep the variations in materials and techniques to a minimum. In view of this, during the initial stages of this study, a number of materials and techniques were tested for their suitability in working with all the viruses selected here. Since fluorescent dyes were considered for use as physical tracers, it was considered essential to determine that their presence in the spray fluid would not be deleterious to the infectivity of the viruses and their quantitation. A great deal of froth was generated when TPB was used as the virus spray and aerosol collection fluid. It was, therefore, necessary to suppress this frothing by the use of an antifoam which would not inactivate the viruses or in some way interfere with virus plaque assay. A known amount of rotavirus SA-I 1. which was the virus used in the initial phases of this study, was suspended in TPB with and without the dyes and the antifoams. The suspensions were held at room temperature for 30 min before being plaque assayed. The results of these tests are presented in Table 1 . Khodamine B and Antifoam C, alone or in combination with each other, reduced the virus plaque titer by at least 4-fold. On the other hand, neither uranine nor Antofoam A. separately or as a mixture, were found to affect the infectivity of the virus. Subsequent tests showed ( Table 2 ) that uranine and Antifoam A were equally harmless to the infectivity of the corona-, polio-, rhino-and other rotaviruses used in this study. In view of this, these two substances were routinely added to the virus spray fluid. Antifoam A was also regularly incorporated in the aerosol collection fluid. During the operation of the Collison nebulizer, virus particles present in the spray fluid are subjected to strong shearing forces. This could lead to the inactivation of the virus being aerosolized. In order to test this, the titer of the virus in the spray fluid was measured before and after operating the nebulizer for 10 min. There was no significant loss in the viability of the corona-, polio, rhino-and rotaviruses tested (Table 3) . These findings established the fact that the Collison nebulizer could be safely used for the aerosolization of all the viruses selected for this study. In an earlier study, it was suggested that the passage of dry air through a dyecontaining spray fluid during the process of nebulization could result in the rapid evaporation of water and thus lead to an increase in the concentration of the dye in the spray fluid (Beard and Easterday, 1965) . In order to test this, the concentration of the dye in the spray fluid (TPB) was measured before and after the operation of the nebulizer for 10 min. As can be seen from the data presented in Table 4 . there was no detectable change observed in the concentration of uranine or rhodamine B in the spray fluid as a result of the process of nebulization. Before any experiments on the airborne survival of the viruses could be carried out, it was considered imperative to determine the suitability of uranine as a physical tracer. In order to do this, uranine and Antifoam A were added to TPB containing "Se-1abelled rotavirus SA-11. This mixture was aerosolized into the rotating drum (50 k 5%. RH: 20 * 1'C) and samples of the air from the drum were collected at appropriate intervals and assayed for the dye. radioactivity and infectious virus. The results are presented in Fig. 2 . The rates of biological decay of the virus calculated using the two different physical tracers were found to be almost the same. These data clearly demonstrated the fact that a fluorescent dye could be not only relatively simple and safe, but also highly reliable as a physical tracer. Apart from the physical loss of the virus, the extent of virus inactivation immediately after its aerosolization depends largely upon the RH and temperature of the aerosol-receiving air. In aerobiology, such a reduction in virus infectivity is generally referred to as the 'initial loss'. That proportion of the airborne virus which survives the initial loss requires a certain amount of time for its uniform distribution in the air inside the rotating drum. In view of this. the first air sample from the drum was always collected 1.5 min after the termination of virus aerosolization. This period of aerosol stabilization was, therefore, considered essential to allow for: (a) the initial loss in virus infectivity to occur. (b) the physical loss of larger particles to take place and (c) the homogeneous distribution of the airborne particles in the air inside the drum. To determine the initial loss in virus infectivity, the amount of virus sprayed into the drum air under different conditions of RH and temperature was compared with the amount recovered in the first air sample. The results of these experiments are presented in Table 5 . At the low and medium RH levels, with an air temperature of 20 ? l"C, the initial loss in the infectivity of the rhino and poliovirus was so pronounced that no infectious virus could be detected in the air samples collected at the end of the aerosol stabilization period. In contrast to this, there was no detectable initial loss in the infectivity of the aerosolized poliovirus when the RH of the air inside the drum was kept at the high level with the air temperature at 20 2 1°C. At 20 ? l"C, the initial loss in the infectivity of the five isolates of rotaviruses tested was the highest at 80 + 5% RH and they appeared to survive best during the aerosolized stabilization period when the RH was at the medium level. Although lowering of the air temperature to 6 ? 1°C showed an increase in the overall capacity of the human rotavirus to survive during the stabilization period, the initial loss in the virus titer was still the lowest at the medium RH level and greatest at the high RH level (Table 6) . At a higher air temperature, the general pattern in the initial loss of the coronavirus was very similar to that seen with the rotaviruses. However, when the air temperature was reduced to 6 + 1°C not only was there a general reduction in the initial loss, but the virus appeared to survive equally well at all 3 RH levels ( Table 6 ). These experiments were performed to determine the size distribution of the virus-containing particles within an aerosol produced by the Collison nebulizer and stored in the rotating drum at the 3 levels of RH (20 + 1°C). Rotavirus SA-11 was After allowing a period of 15 min for aerosol stabilization, the first air sample was collected. To determine the extent of virus survival during this period, the titer of the virus in the air sample was compared with the amount of virus aerosolized. At least 3 separate experiments were conducted and the results are presented as the mean k S.D. suspended in TPB containing the dye and the antifoam. The virus suspension was sprayed into the drum and the viral aerosols held at the desired RH level. At 0.25, 2, 8 and 24 h after aerosolization, samples of the air from the drum were collected with the help of an Anderson sampler (Anderson, 1958) according to the procedure described in Materials and Methods. The gelatin-containing medium from each of the six plates in the sampler was collected separately after incubating the plates for 1 h at 37°C. These samples were then assayed for the dye as well as the infectious virus. A 10 ml volume of TPB containing the virus and uranine (1 mg/ml) was added to the Collison nebulizer and aerosolized into the rotating drum. After 15 min of cloud stabilization, a 1-min air sample (28 I) was drawn with the help of the Anderson sampler. Samples from each of these stages of the sampler were divided into two portions. The virus was quantitated by plaque assay and the concentration of the dye was measured by spectrophotofluorometry. a Stages No. 4, 5 and 6 are designed to recover particles with diameters of 2.0 -3.3 urn, 1.0 -2.0 pm and cl.0 urn, respectively. A 10 ml volume of TPB containing the virus and uranine (1 mg!ml) was added to the Collison nebulizer and aerosoiized into the rotating drum. After 1.5 min of cloud stabilization, a l-mm air sampie (28 1) was drawn with the help of the Anderson sampler. Samples from each of the stages of the sampler were divided into two portions. The virus was quantitated by plaque assay and the concentration of the dye was measured by spectrophotofluorome?ry. a Stages No. 4, 5 and 6 are designed to recover particles with diameters of 2.0 -3.3 urn, 1.0 -2.0 pm and