key: cord-0759627-3zlh4l3o authors: Flynn, M. J.; Snitser, O.; Yelin, I.; Flynn, J.; Green, S.; Szwarcwort, M.; Kishony, R.; Elowitz, M. B. title: A simple direct RT-LAMP SARS-CoV-2 saliva diagnostic date: 2020-11-22 journal: nan DOI: 10.1101/2020.11.19.20234948 sha: f6bf970ce6c5ef2be369307b37f3d7afa6f1b1b4 doc_id: 759627 cord_uid: 3zlh4l3o Widespread, frequent testing is essential for curbing the ongoing COVID-19 pandemic. Because its simplicity makes it ideal for widely distributed, high throughput testing, RT-LAMP provides an attractive alternative to RT-qPCR. However, most RT-LAMP protocols require the purification of RNA, a complex and low-throughput bottleneck that has often been subject to reagent supply shortages. Here, we report an optimized RT-LAMP-based SARS-CoV-2 diagnostic protocol for saliva and swab samples. In the protocol we replace RNA purification with a simple sample preparation step using a widely available chelating agent, as well as optimize key protocol parameters. When tested on clinical swab and saliva samples, this assay achieves a limit of detection of 105 viral genomes per ml, with sensitivity close to 90% and specificity close to 100%, and takes 45 minutes from sample collection to result, making it well suited for a COVID-19 surveillance program. Widespread testing is seen as the solution for preventing the spread of SARS-CoV-2, but must include the testing of asymptomatic people to be effective. While much progress has been made in addressing the COVID-19 pandemic, treatments remain limited and vaccines have not finished deployment. In the meantime, societies' best option for containment is to follow "test and trace" approaches where those recently exposed to SARS-CoV-2 quarantine themselves so they do not spread the virus further. However, in most countries including the US, tests are typically administered only after symptoms develop. A growing scientific consensus holds that effective epidemiological approaches for containing the virus must also include routine testing of asymptomatic people 1 . Testing for SARS-CoV-2 after the onset of symptoms misses a crucial window of pre-symptomatic infectivity. Viral loads decrease over time in most patients hospitalized with SARS-CoV-2, indicating a peak in viral load sometime at or before symptom onset 2 . This is consistent with data from a nursing home outbreak showing a subpopulation of presymptomatic patients with very high viral loads (C t ~13.7-18) that was not seen in the symptomatic patients 3 . Similarly, statistical analysis on cases of transmission comparing time between symptom onsets with the incubation period of the virus inferred a peak infectivity 0-1 days before symptom onset 4 . If viral load and infectivity peak before symptom onset, then it is likely that a patient will have spread the virus before they are able to quarantine themselves. In this vein, modeling indicates that testing will only be effective if conducted on asymptomatic individuals across the population 1 . However, operating at this scale places significant constraints on the design of a test. The most common and effective testing method, RT-qPCR, suffers from high costs, a requirement for infrastructure and operational complexity. Polymerase chain reaction (PCR) is a foundational method in molecular biology whereby short DNA "primers" are annealed to a DNA template of interest, extended by DNA polymerase, creating a copy of the template, and then dissociated at high temperature to begin the cycle again. Quantitative polymerase chain reaction (qPCR) couples this DNA synthesis to fluorescence using a DNA binding dye or other method, which allows a quantitative readout. By comparing the number of cycles (doublings) required to reach a measurable fluorescence, the C t value, the amount of template DNA in the sample can be roughly quantified. Reverse Transcriptase qPCR, RT-qPCR, adds a reverse transcription reaction to the beginning in order to target RNA. RT-qPCR is an essential laboratory method and highly sensitive, able to detect down to 10 3 SARS-CoV-2 genome copies per ml in clinical swab samples. However, the assay also has several drawbacks we hope to address in this work. The first aspect to improve is cost: the price of a COVID-19 qPCR test is limiting in nearly all settings and ranges from $20 to greater than $100 per test. A second, related aspect is equipment to run the qPCR test, which can cost many thousands of dollars. A third aspect is test complexity: an RT-qPCR test requires molecular biology expertise to conduct and interpret, which restricts its execution to labs equipped with this expertise (CLIA labs in the USA). The resulting logistical challenge of collecting, shipping, and processing samples from different locations at these limited number of labs increases test turnaround time and reduces throughput. An ideal test would be cheap and simple enough to conduct at the point of care in low resource settings. Other limitations of the general testing regime include RNA extraction and sample collection. RT-qPCR and other methods require RNA extraction from a sample before use in the assay. RNA extraction is costly, low throughput, subject to reagent shortages, and requires molecular biology expertise to conduct, which makes it desirable to skip. Additionally, nasopharyngeal swabs have often been in short supply and are painful and dangerous to collect. By contrast, saliva collection, which is non-invasive, safer to collect, and not dependent on swabs or other supplies, yields comparable or higher viral loads compared to nasopharyngeal swabs 5 . Thus, an ideal assay would skip RNA extraction and could be run on saliva. A surveillance assay need not be as sensitive as qPCR. After infection is established, RNA viruses enter an exponential phase during which viral load rises from undetectable to orders of magnitude higher than the LOD of qPCR in as little as 1-2 days. Based on this fact, mathematical modeling suggests that diagnostic tests that have 1000-fold higher LOD than qPCR can still be effective, if individuals are tested often enough to catch the spike 1 . Therefore, sensitivity can be traded off to satisfy the other constraints. Colorimetric RT-LAMP can address many of the key issues currently limiting testing. Colorimetric Reverse Transcriptase Loop-mediated Isothermal Amplification (RT-LAMP) is a method for detecting a specific RNA species using an isothermal polymerase reaction. In this method, primers are designed such that a target RNA triggers a chain reaction of DNA hairpin synthesis 6, 7 , which is read out by a pH sensitive dye that turns yellow as protons are released by DNA polymerization 8 . Since it does not require a PCR machine, RT-LAMP is ideal for field testing of viral infections and has been used for Ebola diagnosis and surveillance in Guinea 9,10 , for tracking Zika virus in Brazilian mosquito populations 11 , and for COVID-19 diagnosis during the initial outbreak in Wuhan and Shenyang, China 12, 13 . Recent work has solidified RT-LAMP as a simple, inexpensive, and sufficiently sensitive alternative to RT-qPCR for SARS-CoV-2 detection [14] [15] [16] [17] [18] [19] [20] [21] [22] [23] [24] [25] [26] . Here, adding a chelating agent and optimizing reaction volume, we demonstrate significant improvements to RT-LAMP. First we show that the non-hazardous chelating agent Chelex-100 can be used to prepare saliva samples for RT-LAMP, similar to how it has been used to prepare complex forensic samples for PCR [27] [28] [29] . By sequestering divalent metal cations, Chelex-100 protects RNA from degradation at high temperature. Chelex-100 also has a basic pH which reduces sensitivity to variations in patient saliva pH without inhibiting LAMP. Second, we found that larger reaction volumes can provide greater sensitivity. With these optimizations, we achieved a limit of detection of 10 5 RNA copies per ml and got results consistent with RT-qPCR on clinical swab samples with C t up to 32, yielding a sensitivity near 90% and specificity near 100% on clinical swab and saliva samples. Chelex-100 can partially protect RNA from high temperature degradation. We first set out to eliminate the need for RNA purification from saliva samples. To create synthetic samples for testing, the SARS-CoV-2 N gene (IDT # 10006625) was in-vitro transcribed, quantified with digital PCR, serially diluted in 10-fold steps, and spiked into human saliva. The samples could then be treated with various sample preparation techniques and added to a 10 µl colorimetric RT-LAMP reaction for readout, for which we used a previously published primer set targeting the N gene, N2 22 (see Methods). We explored multiple approaches to inactivate potential inhibitors in the samples, including proteinase K to degrade protein-based inhibitors as well as a 95C heat inactivation step. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 22, 2020. ; With heat inactivation, we confirmed a recently reported result that assay sensitivity was significantly higher when RNA is added after saliva has been heat treated than before, implying a significant amount of temperature-induced degradation 17 (Figure 1 , second and third panels). We hypothesized that RNA degradation at high temperatures is caused by enhancement of RNA hydrolysis by divalent metal cations, which mediate nuclease activity at biological temperatures 30 . These cations attack phosphodiester bonds, cleaving the RNA backbone 30 . However, chelating agents can sequester these cations. In particular, the chelating agent Chelex-100 has been used to prepare RNA and DNA for PCR from complex forensic samples such as blood and saliva 28, 29 . In keeping with standard Chelex-100 protocols, synthetic samples were mixed 2:3 with 10% wt/vol Chelex-100 solution, incubated at 95C for 10 minutes, and then assayed with RT-LAMP. Using this sample prep, the degradation due to heat inactivation was reduced 100-fold ( Figure 1 , fourth panel). In each tube, yellow colorimetric readout indicates RT-LAMP amplification. To prepare the samples, pure RNA was spiked into saliva at a 1:10 dilution, which is why the first panel is offset relative to the others. The limit of detection (LOD, yellow circle) of RT-LAMP on saliva samples is 10,000-fold lower if spiked RNA is added after heat inactivation (second row) than if it is added before (third row), indicating that a significant amount of RNA is being degraded as a consequence of the heat. Adding a chelating agent, Chelex-100, to the saliva before heat inactivation partially protects RNA from this degradation (fourth row). . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 22, 2020. ; https://doi.org/10.1101/2020.11.19.20234948 doi: medRxiv preprint Optimization of Chelex-100 sample preparation Temperature, incubation time, and Chelex-100 concentration affect sensitivity. Starting from a base protocol which used a 10 minute incubation at 95C with a 10% wt/vol Chelex-100 solution, we conducted one round of optimization by individually varying incubation time ( Figure 2A ), temperature ( Figure 2B) , and Chelex-100 concentration ( Figure 2C) , and compared the resulting limits of detection. The initial incubation time and temperature, 10 minutes and 95C, respectively, were near optimal. However, increasing Chelex-100 concentration from 10% to 30% wt/vol improved assay sensitivity 10-fold ( Figure 2C ). With the resulting optimal conditions, we achieved a sensitivity of 10 7 copies per ml from human saliva ( Figure 2C ). However, SARS-CoV-2 genome concentrations in patient saliva range from 10 3 to 10 9 copies per ml 2,5 . Therefore, we sought additional optimizations before moving to clinical samples. Since RT-LAMP is an all-or-nothing reaction, its sensitivity should be proportional to the total number of template molecules. Intuitively, a larger volume at lower sample concentration should yield a similar result as a lower volume at higher sample concentration, assuming the same concentration ⨉ volume product. This would effectively increase sensitivity at higher volumes. To test this, we varied the RT-LAMP total reaction volume. Surprisingly, sensitivity increased super-linearly, rather than only linearly, as expected, over reaction volumes of 10 to 100µl. This occurred with both pure RNA samples and human saliva samples ( Figure 2D ). 100μl reactions with the Chelex-100 sample prep yielded LODs in saliva of 10 5 copies per ml or better. Further increasing the reaction volume to 250 μl caused an increase in false positives (not shown), and was not pursued further. Other optimizations failed to increase sensitivity beyond 10 5 RNA copies per ml. 40 mM Guanidine HCL was shown in other work to increase sensitivity of RT-LAMP 22 . Also, certain engineered polymerase and reverse transcriptase enzymes have been reported to be especially resistant to inhibitors, such as ThermoFisher Superscript IV reverse transcriptase and NEB BST 3.0 polymerase 31 . Starting from the optimized assay, we added each of these components to the reaction individually ( Figure 2E ). In each case, the resulting LOD was the same or worse than the base assay . Based on these results, and the sufficiency of 10 5 copies/ml for recent studies of high frequency testing strategies, we decided to go forward with testing on clinical COVID-19 samples. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 22, 2020. ; Chelex RT-LAMP measurement of unpurified clinical samples strongly correlated with qRT-PCR analysis of purified RNA. We evaluated the protocol on clinical throat and nose swabs, collected in universal or viral transport media (UTM/VTM) for analysis by the Virology laboratory at the Rambam Health Care Campus in Haifa, Israel. We compared qRT-PCR analysis of purified RNA to Chelex RT-LAMP analysis of the same samples without RNA Figure 2 : A Chelex-100 based sample preparation was optimized by varying parameters one at a time. Starting from an initial protocol where 10% wt/vol Chelex-100 was mixed 3:2 with sample and incubated for 10 minutes at 95 C, individual parameters were varied and the LOD (yellow circle) was compared. We found that (A) a 10 minute incubation time, (B) a 95C incubation temperature, and (C) 30% wt/vol Chelex-100 stock solution optimized LOD. Additionally, increasing the volume of the RT-LAMP reaction from 10 µl to 100 µl increased sensitivity by at least 100-fold (D), but increasing the volume further caused an increase in false positives (not shown). Based on reports in other publications, we also tried adding 40 mM guanidine HCL 22 , Superscript IV reverse transcriptase, and Bst 3.0 to increase sensitivity, however the LOD was unchanged by these additions (E). Based on these experiments, we called the final sensitivity at 10 5 copies/ml. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted November 22, 2020. ; https://doi.org/10.1101/2020.11.19.20234948 doi: medRxiv preprint purification. More specifically, we chose 31 positive and 31 negative samples that had been previously routinely analyzed in the laboratory by RT-qPCR (2019-nCoV detection kit, Seegene, CA, USA), with RNA extracted using either automated NucliSENSE easyMAG or using a magLEAD automated extraction platform. The RT-qPCR analysis produced C t values ranging from 17 to 34. We then analyzed the original unpurified material for the same samples. For each sample, we mixed 60 µl of the sample with 90 µl 30% Chelex-100 solution, and heated to 95C for 10 minutes. Then, we added 10 µl of the resulting mixture to a 100 µl RT-LAMP reaction with the N2 primer set ( Figure 3A) . One negative control sample of sterile UTM was included in each set of samples ( Figure 3A, label NC) . Among the 31 negative samples, no strong positive outcomes were observed, although a few samples showed slight orange color ( Figure 3A , arrowheads). By contrast, among the 31 positive samples, 27 showed strong color change. Among these, all 21 of the samples with C t <28 correctly showed positive results ( Figure 3B) . These results indicate a strong correlation between the Chelex RT-LAMP measurement on unpurified samples and the qRT-PCR analysis of purified RNA. Defining sensitivity as the fraction of positive samples that were returned positive by the assay, we next asked whether we could identify a quantitative C t threshold separating the regime with nearly perfect sensitivity from that where there is no detection. We assumed that the sensitivity of the diagnostic as a function of C t could be described by a logistic model with two parameters: C 0 , defined as the C t value where sensitivity S=½, and ꞵ, the slope of S at C 0 : We fit the model using Bayesian inference (see Methods), yielding a posterior distribution with a median C 0 estimate of 31.9 with a 95% confidence interval of [29.8, 36 .0], and a median ꞵ estimate of 1/8.99 (95% confidence interval [1/19.9, 1/4.66]) ( Figure 3B-D) . More precise parameter estimates will require additional data. However, these inferences are consistent with the assay being highly robust for samples with C t below 28 and sensitive enough to detect at least half of samples with C t values of up to ~32. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted November 22, 2020. ; This protocol correctly identified 93% of positive saliva samples and 100% of negative saliva samples in a test of emergency room patients. As approved by the CMC Institutional Review Board, patients at Catholic Medical Center requesting COVID-19 tests volunteered saliva samples that were then marked with the positive or negative result of the PCR test. 20 negative samples and 14 positive samples were then assayed with the protocol developed in this paper (see Protocol), using the N1 primer set, which has similar sensitivity to the N2 primer set 32 . No negative samples yielded a positive readout after 45 minutes, however 13/14 positive samples did (93%, Figure 4 ). This confirms that this assay can be used as a simple, direct means to test saliva samples for SARS-CoV-2. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 22, 2020. ; https://doi.org/10.1101/2020.11.19.20234948 doi: medRxiv preprint In this work, we optimized a SARS-CoV-2 detection protocol to prepare saliva and nasopharyngeal swab specimens for RT-LAMP without RNA purification. The use of high concentrations of Chelex-100 protected RNA from heat induced degradation, and a high temperature incubation inactivated inhibitors in the saliva. An increased volume of the RT-LAMP reaction allowed larger sample volumes in the reaction, which yielded increased sensitivity. Altogether, this protocol achieved a sensitivity of 10 5 SARS-COV-2 RNAs / mL, robustly detected the virus in samples up to a Ct of 28, and was able to detect the virus in samples with Ct up to 32, without false positives in negative samples. This protocol enables the implementation of high throughput population screening. Saliva collection is safer, easier, and less invasive than swab collection. Since Chelex-100 is a non-hazardous reagent, it can be included in self-collection kits. Once samples have been collected, they can be quickly heat inactivated, and processed in parallel on PCR plates, . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 22, 2020. ; allowing many reactions to be conducted at a time. By contrast, many alternative diagnostic protocols require uncapping of samples, mixing of additional reagents into samples, and other kinds of sample handling such as centrifugation to purify RNA or otherwise prepare the sample for the assay. By making this sample handling unnecessary, this sample prep method is safer, faster, and higher throughput. There are still issues to be worked out. A limitation of this protocol is that the increased volume of the assay leads to a reaction cost of ~$7. This cost can be potentially reduced by reducing the volume to the 25 µl to achieve ~$2 per reaction, albeit with reduced sensitivity. Additionally, use of open source enzymes 26, 33 and pooling the samples could further reduce costs. As the volume of LAMP reaction increases, false positive results seem to increase in frequency which manifested as a few negative samples turning orange in our experiments presented here. These problems could potentially be mitigated by the inclusion of UDG/UTP in the LAMP reaction, which others have used successfully to reduce false positives 26 . These problems could also be reduced by running reactions with 2 different primer sets, which should increase certainty of a positive or negative result. With the current surge in Covid-19 across the US and the world this technology could prove very helpful to fill the void for rapid, affordable, easily deployable, widely distributed testing. derivative of the sensitivity function at C t = C 0 is -ꞵ and that we expected the sensitivity to drop from around 1 at C t =28 to around 0 at C t = 35, which would imply the scale of the slope is on the order of magnitude of 1/7. Thus, the ꞵ prior was chosen to be gaussian with mean 1/7, with standard deviation equal to 2/7, to allow for some flexibility. Both priors were restricted to the positive real line. Transition probabilities for C 0 and ꞵ were gaussian with mean zero and standard deviation of 1 and .1, respectively. 1 million points were sampled from the posterior distribution, and the .05, .5, .95 quantiles for both ꞵ and C 0 were computed. -Chelex-100 (Bio-Rad #1421253) -WarmStart® Colorimetric LAMP 2X Master Mix (NEB #M1800S/#M1800L) -Nuclease free water (VWR #10220-398) -N2 primers: -N1 primers: Important Note: It is recommended that these primers (both N1 and N2) be PAGE purified for the highest sensitivity and lowest off-target amplification. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 22, 2020. ; Prepare 30% wt/vol Chelex stock solution: 1. Add 4.5 g Chelex-100 to a 15 mL tube 2. Fill with deionized water up to 15 mL 3. Shake to mix until no white clumps are visible. The final solution should look like a milky slurry that settles to the bottom of the tube relatively quickly (~ 1-3 mins). In a PCR tube, mix: This gives 10 reactions for a 100 µl volume LAMP reactions. For more reactions, these numbers can be scaled proportionally. For 100 µl of fresh saliva/swab in VTM: 1. Shake Chelex-100 stock solution vigorously to resuspend the resin (because Chelex is quick to settle, it should be reshaken every 3 samples or so if they are being done in succession) 2. Add 150 µl of the resuspended 30% Chelex-100 stock solution to the 100 µl saliva, pipette up and down to mix thoroughly. 3. Incubate samples in a 95 C wet bath (or thermocycler or aluminum 96-well plate) for 10 minutes. 4. While the Chelex-saliva solution is heating, prepare a mixture of -50 µl Warmstart Colorimetric LAMP Master Mix (thawed on ice) -10 µl N2 primer master mix -30 µl nuclease free water on ice for each sample. 5. After 10 minutes, remove Chelex-saliva solution from heat, place on ice for 2 mins. 6. Spin Chelex-saliva solution in a PCR tube mini centrifuge for a 5 second pulse. 7. Pipette 10 µl from the top of the Chelex-saliva supernatant into the Lamp mixture, final volume should be 100 ul. 8. Heat the final lamp mixture at 65 C for 30 minutes. . CC-BY 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted November 22, 2020. ; https://doi.org/10.1101/2020.11.19.20234948 doi: medRxiv preprint Test sensitivity is secondary to frequency and turnaround time for COVID-19 surveillance. medRxiv (2020) Virological assessment of hospitalized patients with COVID-2019 Presymptomatic SARS-CoV-2 Infections and Transmission in a Skilled Nursing Facility Temporal dynamics in viral shedding and transmissibility of COVID-19 Saliva is more sensitive for SARS-CoV-2 detection in COVID-19 patients than nasopharyngeal swabs Loop-mediated isothermal amplification of DNA Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes Development and Evaluation of Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay Coupled with a Portable Device for Rapid Diagnosis of Ebola Virus Disease in Guinea Deployment of a Reverse Transcription Loop-Mediated Isothermal Amplification Test for Ebola Virus Surveillance in Remote Areas in Guinea Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil Rapid Molecular Detection of SARS-CoV-2 (COVID-19) Virus RNA Using Colorimetric LAMP Rapid colorimetric detection of COVID-19 coronavirus using a reverse tran-scriptional loop-mediated isothermal amplification (RT-LAMP) diagnostic plat-form: iLACO. medRxiv SARS-CoV-2 On-the-Spot Virus Detection Directly From Patients Rapid and extraction-free detection of SARS-CoV-2 from saliva with colorimetric EasyCOV : LAMP based rapid detection of SARS-CoV-2 in saliva A community-deployable SARS-CoV-2 screening test using raw saliva with 45 minutes sample-to-results turnaround Initial evaluation of a mobile SARS-CoV-2 RT-LAMP testing strategy Handyfuge-LAMP: low-cost and electricity-free centrifugation for isothermal SARS-CoV-2 detection in saliva SARS-CoV-2 Detection Using an Isothermal Amplification Reaction and a Rapid, Inexpensive Protocol for Sample Inactivation and Purification A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples Enhancing colorimetric loop-mediated isothermal amplification speed and sensitivity with guanidine chloride Preliminary optimisation of a simplified sample preparation method to permit direct detection of SARS-CoV-2 within saliva samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP). medRxiv Standard operating procedures for SARS-CoV-2 detection by a clinical diagnostic RT-LAMP assay SARS-CoV-2 RNA extraction using magnetic beads for rapid large-scale testing by RT-qPCR and RT-LAMP A rapid, highly sensitive and open-access SARS-CoV-2 detection assay for laboratory and home testing Defining the relative performance of isothermal assays that can be used for rapid and sensitive detection of foot-and-mouth disease virus Inhibitory effect of salivary fluids on PCR: potency and removal Chelex 100 as a medium for simple extraction of DNA for PCR-based typing from forensic material The Role of Metals in the Hydrolytic Cleavage of DNA and The authors declare no competing interests. The Metropolis-Hastings algorithm was used to sample parameters from the posterior distribution of ꞵ and C 0 , using the logistic model .. Priors were constructed by analyzing the expected scale of the parameters. Since it was unlikely that this LAMP assay did significantly worse or better than PCR, a Gaussian prior was chosen for C 0 , with mean 30 and standard deviation 10. For the ꞵ prior, we noted that the