key: cord-0757677-0zbnx5a8 authors: Liu, Zixuan; Yin, Zheng-Zhi; Cai, Wenrong; Wu, Datong; Li, Junyao; Kong, Yong title: A surface protein−imprinted biosensor based on boronate affinity for the detection of anti−human immunoglobulin G date: 2022-02-15 journal: Mikrochim Acta DOI: 10.1007/s00604-022-05204-w sha: ddbd6abfb14fa1486d6bbefe8dbb8d8bae073b5a doc_id: 757677 cord_uid: 0zbnx5a8 A surface protein-imprinted biosensor was constructed on a screen-printed carbon electrode (SPCE) for the detection of anti-human immunoglobulin G (anti-IgG). The SPCE was successively decorated with aminated graphene (NH(2)-G) and gold nanobipyramids (AuNBs) for signal amplification. Then 4-mercaptophenylboric acid (4-MPBA) was covalently anchored to the surface of AuNBs for capturing anti-IgG template through boronate affinity binding. The decorated SPCE was then deposited with an imprinting layer generated by the electropolymerization of pyrrole. After removal of the anti-IgG template by the dissociation of the boronate ester in an acidic solution, three-dimensional (3D) cavities complementary to the anti-IgG template were formed in the imprinting layer of polypyrrole (PPy). The molecularly imprinted polymers (MIP)-based biosensor was used for the detection of anti-IgG, exhibiting a wide linear range from 0.05 to 100 ng mL(−1) and a low limit of detection of 0.017 ng mL(−1) (S/N = 3). In addition, the MIP-based anti-IgG biosensor also shows high selectivity, reproducibility and stability. Finally, the practicability of the fabricated anti-IgG biosensor was demonstrated by accurate determination of anti-IgG in serum sample. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-022-05204-w. Antibodies are glycoproteins involved in the pathogenesis of autoimmune diseases, which play a critical role in immunopathology [1] . The past years have witnessed the detection of antibodies as an important approach for the diagnosis of several diseases such as HIV [2] , dengue [3] , Zika virus [4] and autoimmune diseases [5] . Particularly, due to the fast global spread of coronavirus disease (COVID-19) from the end of 2019, assay of immunoglobulin G (IgG) and immunoglobulin M (IgM) antibodies for evaluating the diagnostic accuracy is especially important for COVID-19 patients [6] . As a valuable alternative, electrochemical biosensors can be regarded as a feasible strategy for the rapid, specific and sensitive detection of antibodies at the point-of-care [7] . It is usually difficult for the imprinting of biological macromolecules (e.g. proteins) due to their restricted mobility within the highly cross-linked polymer matrix [8] . Apart from this, imprinting under harsh conditions often leads to protein denaturation [9] . Compared with small organic molecules used as the templates in molecularly imprinting polymers (MIP), proteins possess complex surface binding sites, and therefore appropriate complementarities and polymerization procedures are especially essential for successful fabrication of MIP-based protein sensors [10] . Various imprinting strategies such as surface imprinting [11] , epitope imprinting [12] and microcontact imprinting [13] have been proposed to solve these problems frequently encountered by proteins imprinting. Among the developed methods, surface imprinting is especially attractive owing to its high binding capacity, rapid mass transfer and efficient removal of template [14] . Recently, boronate affinity controllable-oriented imprinting has been utilized for surface imprinting since it can allow easy and efficient preparation of MIP specific to glycoproteins [15] . For example, Wang et al. reported that a glycoprotein template was covalently anchored onto the surface of a boronic acid-functionalized substrate through boronate affinity binding for the preparation of MIP [16] . The principle of boric acid affinity is that under the condition of pH 6 ~ 10, boric acid can covalently interact with molecules containing cis-diol to form stable cycloesters, which will be dissociated at pH < 3, and this reversible binding makes boric acid an excellent affinity ligand for MIP [17] . Electropolymerization is a straightforward approach for the preparation of polymers used as the matrix of surface imprinting [18] , since the thickness and the morphology of the electrodeposited polymer films can be controlled through electropolymerization conditions [19] . To enhance the sensitivity of MIP-based sensors, various nanomaterials such as gold nanoparticles (AuNPs), carbon nanotube (CNT) and graphene have been used for electrode modification [20] . Among them, graphene has received increasing attention in electrochemical biosensors due to its robust mechanical property as well as high conductivity and electron mobility [21] . In addition, graphene can also be coated with metal or metal oxide NPs for signal amplification [22] . As another kind of important nanomaterials, AuNPs exhibit high chemical stability and electron transfer capacity, excellent biocompatibility, which have been widely used in electrochemical bioanalysis. However, the commonly used AuNPs are spherical in shape, and little attention has been paid to the use of Au nanobipyramids (AuNBs) in biosensors [23] . Compared with spherical AuNPs, AuNBs might be a potential alternative to obtain higher sensitivity owing to their sharper tips [24] . In fact, the plasmonic responses and local field enhancement of noble metal NPs can be tuned through their shape and size [25] , which can in turn influence the voltammetric signals of the noble metal NPs. In this work, a novel surface protein-imprinted biosensor based on boronate affinity was proposed for the detection of anti-IgG. A screen-printed carbon electrode (SPCE) was successively decorated with aminated graphene (NH 2 -G) and AuNBs for signal amplification, which was further decorated with 4-mercaptophenylboric acid (4-MPBA) through Au-S bond. The anti-IgG template can be covalently anchored to the surface of 4-MPBA through the specific boronic acid-diol binding, and then the substrate was deposited with an imprinting layer generated by the electropolymerization of pyrrole. After removal of the template in an acidic solution, the MIP-based biosensor was obtained, which can be successfully applied in the sensitive and selective detection of anti-IgG by using [Fe(CN) 6 ] 3−/4− as the signal probe. Tetrachloroauric (III) acid trihydrate (HAuCl 4 ·3H 2 O), trisodium citrate dihydrate, ascorbic acid (AA), silver nitrate (AgNO 3 ), hydrochloric acid (HCl), cetyltrimethylammonium bromide (CTAB), sodium borohydride (NaBH 4 ), potassium chloride (KCl), sodium chloride (NaCl), calcium chloride (CaCl 2 ), sodium bicarbonate (NaHCO 3 ) and ethanol were purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Aminated graphene (NH 2 -G), graphene oxide (GO), -COOH functionalized graphene (COOH-G), -OH functionalized graphene (OH-G) and nitrogen-doped graphene (N-G) were obtained from Chengdu Organic Chemicals Co., Ltd., Chinese Academy of Sciences (Chengdu, China). 4-Mercaptophenylboric acid (4-MPBA), bovine serum albumin (BSA), glucose (Glu), L-tyrosine (L-Tyr) and hemoglobin (HGB) were purchased from Aladdin Chemistry Co., Ltd. (Shanghai, China). Pyrrole was received from Shanghai Macklin Biochemical Technology Co., Ltd. (Shanghai, China). Goat anti-human IgG (anti-IgG) and rabbit anti-IgG immune serum sample were obtained from Beijing Solarbio Science and Technology Co., Ltd. (Beijing, China). Screen-printed electrodes with working (d = 5 mm) and counter electrode of carbon and a reference electrode of silver were purchased from NEOPRO Biotechnologies Co. Ltd. (Weihai, China). All aqueous solutions were prepared with ultrapure water (18.2 MΩ cm, Millipore). Transmission electron microscopy (TEM) and scanning electron microscopy (SEM) characterizations of different samples were conducted with a JEM 2100 transmission electron microscope (JEOL, Japan) and a Supra55 fieldemission scanning electron microscope (Zeiss, Germany), respectively. The visible absorption spectrum of AuNBs was recorded by using a U-3900 UV-Vis spectrophotometer (Hitachi, Japan). All electrochemical experiments including cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) were carried out on a CHI 660E electrochemical workstation (Shanghai Chenhua Instruments Co., Ltd., China). AuNBs were synthesized by the seed-mediated growth method previously reported [26] , and the detailed procedures were described in Supporting Information. For control experiments, Au nanoparticles (AuNPs) and Au nanorods (AuNRs) were also synthesized according to the previous literatures [27, 28] , respectively. Five microliters of the NH 2 -G dispersion (1.0 mg mL −1 ) was dropped onto the SPCE surface and allowed to dry in ambient air. Next, 5.0 μL of the AuNB suspension (0.4 mg mL −1 ) was gently dropped onto the NH 2 -G/SPCE surface and dried in ambient air. After that, 5.0 μL of ethanol containing 1.0 mM 4-MPBA was dropped on the AuNBs/NH 2 -G/ SPCE surface and dried in ambient air, and 4-MPBA was self-assembled on the electrode surface through Au-S bond. After every step of modification, the unbound modifier was washed off by water. Finally, 5.0 μL of 0.1 M phosphate buffer saline (PBS, pH = 7.4) containing 100 μg mL −1 anti-IgG was dropped onto the MPBA/AuNBs/NH 2 -G/SPCE surface. After incubation for 12 h, the unbound anti-IgG was washed successively by 0.1 M PBS of pH 7.4 and water, and the resultant electrode was denoted as Anti-IgG/MPBA/ AuNBs/NH 2 -G/SPCE. One hundred microliters of 0.01 M PBS containing 0.1 M pyrrole was dropped onto the surface of the Anti-IgG/ MPBA/AuNBs/NH 2 -G/SPCE, and the electropolymerization of pyrrole was carried out by CV in the potential range between − 0.3 and 0.8 V at a scan rate of 50 mV s −1 for 10 cycles. After that, 100 μL of 0.2 M HCl was dropped onto the surface and kept for 25 min to remove the entrapped anti-IgG template. After washing with 0.1 M PBS, the MIP biosensor denoted as MIP/MPBA/AuNBs/NH 2 -G/SPCE was obtained. For control experiments, the non-imprinted biosensor was also fabricated by the same procedure in the absence of anti-IgG, which was denoted as NIP/MPBA/ AuNBs/NH 2 -G/SPCE. The as-fabricated MIP biosensor was incubated with different concentrations of anti-IgG in 5.0 μL 0.1 M PBS at 4 °C for 6 h, which was then washed with 0.1 M PBS to remove the free anti-IgG. Next, the rebound anti-IgG to the biosensor was detected by DPV in 0.1 M PBS containing 0.1 M KCl and 5 mM [Fe(CN) 6 ] 3−/4− used as the signal probe. Schematic illustration showing the fabrication of the MIP biosensor and the detection of anti-IgG is presented in Fig. 1 . To demonstrate the practicality of the proposed MIP biosensor, anti-IgG in serum sample is detected with the MIP biosensor by standard addition method. Purified rabbit anti-IgG immune serum (50 μL) was diluted with 5 mL PBS of pH 7.4, and then different concentrations of anti-IgG (ranging from 0.5 ng mL −1 to 2.0 ng mL −1 ) were added into the diluted sample, respectively, which were detected by DPV in the potential range from − 0.2 to 0.8 V. First, AuNBs, AuNPs and AuNRs are characterized by visible spectra ( Fig. S1 in Supporting Information). Two distinct bands appear at around 535 and 725 nm, respectively, on the visible absorption spectrum of AuNBs. The former could be attributed to the combination of interband transitions and transverse plasmon resonances from the bases of AuNBs and the byproduct spherical particles, while the latter corresponds to the longitudinal plasmon resonance of AuNBs [29] . The visible spectrum of AuNBs clearly indicates that The absorption band of AuNPs (520 nm) is near to the transverse plasmon resonance of AuNBs (535 nm), suggesting that the size of AuNPs is similar to the transverse size of AuNBs. The absorption band of AuNRs (800 nm) is greatly longer than the longitudinal plasmon resonance of AuNBs (725 nm), suggesting that the length of AuNRs is greater than the longitudinal size of AuNBs. These assumptions can be further confirmed by the TEM images of AuNPs and AuNRs (Fig. S2 in Supporting Information). To reveal the successful integration of NH 2 -G and AuNBs, the TEM images of NH 2 -G, AuNBs and AuNBs/NH 2 -G are shown in Fig. 2 . The NH 2 -G exhibits a sheet-like morphology with abundant wrinkles over the layers ( Fig. 2A) , agreeing well with the previous report [30] . Typical bipyramids can be observed for the AuNBs (Fig. 2B) , and the average size of the AuNBs is determined to be 43.48 nm by the software Nano Measurer. As can be seen from Fig. 2C , the AuNBs can be well distributed on the NH 2 -G nanosheets without aggregation, suggesting that the NH 2 -G might be an excellent support for the loading of AuNBs. The SEM images of NH 2 -G, AuNBs/NH 2 -G and MIP/ MPBA/AuNBs/NH 2 -G before and after template removal are shown in Fig. 3 . A multilayered structure is observed for the NH 2 -G, which is accompanied by extensive stacking and folding (Fig. 3A) . The small AuNBs are uniformly anchored onto the NH 2 -G nanosheets (Fig. 3B) . After further electropolymerization of pyrrole, a compact polypyrrole (PPy) film can be observed on the surface (Fig. 3C) , suggesting that electrodeposition of PPy could be a feasible strategy for the formation of the imprinting layer. After the removal of the anti-IgG template in the acidic solution (0.2 M HCl), the MIP/MPBA/AuNBs/ NH 2 -G exhibits a micro-porous structure (Fig. 3D) , which is especially favorable for the further accommodation of the anti-IgG target. Several graphene derivates including GO, COOH-G, OH-G, N-G and NH 2 -G are compared. The results show that among all these modified electrodes, the AuNBs/ NH 2 -G/SPCE displays the highest peak currents on the cyclic voltammograms (Fig. S3 in Supporting Information). N atom has lone pair electrons, which can form stable coordination bonds with Au atom. Compared with other groups such as -COOH, -NH 2 has smaller steric hindrance and can be easier to coordinate with Au. The AuNBs/NH 2 -G/SPCE exhibits the highest peak currents because more amount of AuNBs can be anchored to the surface of the NH 2 -G/SPCE. Therefore, NH 2 -G is chosen for the construction of the anti-IgG biosensor in this work. The cyclic voltammograms of bare SPCE and NH 2 -G/SPCE respectively modified with AuNPs, AuNRs and AuNBs are studied (Fig. S4 in Supporting Information). Among the four tested electrodes, AuNBs exhibit the highest electroactivity since the areas under the cyclic voltammograms of AuNBs/NH 2 -G/SPCE are much larger than those of another two electrodes. The higher electroactivity of AuNBs might be attributed to their sharper tips, which could result in enhanced plasmonic responses and local field. As previously reported [24, 25] , nanoparticles with sharp tips (such as bipyramids and nanotriangles) are particularly sensitive to the change of refractive index and the enhancement of strong magnetic field. In addition, gold nanoparticles with special morphology have higher dielectric displacement among the existing nanoparticles, which can accelerate the electron transfer at the interface, and thus we believe that these unique characteristics of AuNBs may be the reason for their enhanced voltammetric signals. Therefore, AuNBs but not AuNPs and AuNRs are used in this work for electrode modification. The step-by-step modification of the SPCE is characterized by CV and EIS, respectively. Figure ) and AuNBs (curve c), indicating that signal amplification may be achieved by NH 2 -G and AuNBs. Note that after the introduction of electroinactive 4-MPBA through the formation of Au-S bond, the peak currents decrease greatly and are even lower than those at bare SPCE (curve d). The peak currents decrease further after the immobilization of the anti-IgG template through boronate affinity binding (curve e), which might be ascribed to the low conductivity of anti-IgG and the consequent inhibited charge transfer at the electrode/solution interfaces. Figure 4B shows the Nyquist plots of different electrodes in the same electrolyte (frequency range: 10 5 ~ 0.01 Hz; open circuit potential: 0.28 V). The diameter of the suppressed semicircle at high frequency is closely related to the charge transfer resistance (R ct ) [31] , and smaller diameter represents lower R ct . As can be seen, the R ct values of these electrodes are arranged in such an order: AuNBs/NH 2 -G/SPCE (186.8 Ω) < NH 2 -G/SPCE (403.9 Ω) < bare SPCE (548.4 Ω) < MPBA/AuNBs/NH 2 -G/SPCE (11,96.2 Ω) < Anti-IgG/ MPBA/AuNBs/NH 2 -G/SPCE (5441.6 Ω), agreeing well with the results shown in Fig. 4A . Due to the good electron transport capability of NH 2 -G and AuNBs, the R ct value of The cyclic voltammograms obtained during the electrodeposition of PPy on the surface of Anti-IgG/MPBA/AuNBs/ NH 2 -G/SPCE are studied (Fig. S5A in Supporting Information). During the process, the anti-IgG molecules can be entrapped into the polymeric structure of PPy through molecular interactions probably between the hydroxyl groups of anti-IgG and the amine groups of PPy, and the interactions might contribute largely to the formation of the imprinted cavities [32] . Due to the increase in the thickness of the PPy film, the currents decrease with increasing cycling number. The cyclic voltammograms during the electrodeposition of PPy on the surface of MPBA/AuNBs/ NH 2 -G/SPCE are also presented (Fig. S5B in Supporting Information). Note that the currents are greatly higher than those in the presence of anti-IgG although they still decrease as the number of cycles increases, demonstrating that the anti-IgG molecule is not electroactive. Successful removal of the anti-IgG template can be confirmed by CV and EIS, respectively. The cyclic voltammograms of the MIP biosensor at different stages are shown in Fig. 5A . Since anti-IgG is not electroactive, the cyclic voltammograms exhibit low currents before the removal of anti-IgG (curve a). After the treatment with 0.2 M HCl, the currents are significantly enhanced (curve b), which can be ascribed to the fact that the boronate ester linkage between 4-MPBA and the cis-diol groups of anti-IgG is dissociated in the acidic solution (Fig. S6 in Supporting Information), resulting in the removal of anti-IgG and consequently facilitated charge transfer. Note that the currents decrease again after the MIP biosensor is incubated in 0.1 M PBS containing 100 μg mL −1 anti-IgG (curve c), suggesting the rebinding of anti-IgG into the imprinted cavities through the re-formation of boronate ester with 4-MPBA. This phenomenon also demonstrates that the boronate affinity binding between 4-MPBA and anti-IgG is reversible. The EIS results agree well with the results of CV (Fig. 5B) . For comparison, the cyclic voltammograms and the Nyquist plots of the NIP biosensor at different stages are also presented in Fig. 5C , D, respectively. Both the cyclic voltammograms and the Nyquist plots exhibit little differences before and after the treatment with HCl. After the rebinding of anti-IgG, the cyclic voltammograms and the Nyquist plots still remain basically unchanged. Next, the electrochemical kinetics of the MIP biosensor is investigated (Fig. S7 in Supporting Information). It shows that both the anodic peak currents (I pa ) and the cathodic peak currents (I pc ) increase linearly with the square root of the scan rate (v 1/2 ), and the linear regression equations can be described as follows: I pa = 16.46 v 1/2 + 36.26 (R 2 = 0.9998); I pc = − 14.17 v 1/2 -45.17 (R 2 = 0.9959). Obviously, the electrode process of the MIP biosensor is a typical diffusioncontrolled reaction. The standard heterogeneous electron transfer rate constant (k 0 ) is calculated to be 1.26 × 10 −5 cm s −1 from the simulated by ZSimpWin software, where R s represents the ohmic resistance of electrolyte and the internal resistance of electrode, R ct represents the charge transfer resistance, W d represents the Warburg resistance and Q represents the constant phase element peak potential separation (ΔE p ) according to the following equation [33] : where α is the charge transfer coefficient (0.5), n is the electro transfer number (1.0), D is the diffusion coefficient of 5 mM [Fe(CN) 6 ] 3−/4− (7.6 × 10 −6 cm 2 s −1 ), F is Faraday constant (96,485 C mol −1 ), ν is scan rate (0.1 V s −1 ), R is the universal gas constant (8.314 J K −1 mol −1 ), T is temperature (298.15 K), E pa and E pc are the oxidation and reduction peak potential, respectively. After the incubation with anti-IgG of different concentrations for 6 h, the differential pulse voltammograms of the MIP biosensor in 0.1 M PBS (pH = 7.4) containing 0.1 M KCl and 5 mM [Fe(CN) 6 ] 3−/4− are shown in Fig. 6A . Due to the rebinding of anti-IgG into the imprinted cavities in the MIP biosensor, the I pa decreases gradually with increasing concentration of anti-IgG. The calibration plot shows a good linear relationship between I pa and the logarithm value of the anti-IgG concentration in a wide range from 0.05 to 100 ng mL −1 (Fig. 6B) , and the linear regression equation can be expressed as: I pa (μA) = -3.666 lgC (ng mL −1 ) + 30.40 (R 2 = 0.9940). The limit of detection (LOD) is calculated to be 0.017 ng mL −1 based on the signal-to-noise ratio of 3 (S/N = 3). For comparison, the NIP biosensor is also used for the detection of anti-IgG. Even incubation with anti-IgG of a high concentration (100 ng mL −1 ), the I pa varies little compared with the one before incubation (Fig. 6C ). This comparison clearly indicates that the developed MIP biosensor can be used for the detection of anti-IgG. In fact, the developed MIP biosensor is also superior to the sensors previously reported when used for the detection of anti-IgG (Table S1 in Supporting Information). It shows that the developed MIP biosensor displays a wider linear range and a lower LOD than the previous anti-IgG sensors, indicating that our MIP biosensor might be more suitable for the accurate detection of anti-IgG. The imprinting layer depends closely on the thickness of the PPy film, which can be adjusted by controlling the cycle number during the electrodeposition. The highest peak currents on the cyclic voltammograms of the MIP biosensor are observed when the electrodeposition of PPy is carried out for 10 cycles (Fig. 7B) . At less cycle number, the MIP biosensor exhibits less sensitivity, probably due to less imprinted cavities in the MIP film; on the other hand, more cycles would lead to the formation of excessive thickness of film with less accessible imprinted sites [34] . The influence of scan rate for the electrodeposition of polypyrrole on the performance of the MIP biosensor is also studied (Fig. S8 in Supporting Information), and the highest peak currents are observed when PPy is deposited by CV at the scan rate of 50 mV s −1 . Lower scan rates lead to less imprinting cavities in the MIP film, while higher scan rates result in thicker MIP film and difficult elution of the anti-IgG template. In this work, the anti-IgG template is eluted with 0.2 M HCl, and thus the elution time is also optimized. As shown in Fig. 7C , the peak currents on the differential pulse voltammograms of the MIP biosensor first increase with the elution time up to 25 min and then decrease with further increase in elution time. It might be ascribed to the nonspecific absorption of anti-IgG caused by longer elution time and the consequent incomplete removal of the anti-IgG template. Figure 7D shows the influence of incubation time on the peak currents on the differential pulse voltammograms of the MIP biosensor. Due to the rebinding of anti-IgG into the imprinted cavities, the peak currents decrease gradually with increasing incubation time. However, the peak currents remain almost unchanged after incubation for 6 h, indicating that the imprinted cavities in the MIP film are completely occupied by the target anti-IgG. Further, the influence of pH for anti-IgG detection on the performance of the MIP biosensor is studied (Fig. S9 in Supporting Information). As can be seen, the highest peak currents are obtained at pH 7.4. Therefore, pH 7.4 is chosen as the optimized pH value for the detection of anti-IgG. The selectivity of the MIP biosensor is studied by the detection of anti-IgG, BSA, Glu, L-Tyr, HGB, Na + , K + , Ca 2+ , Cl − and HCO 3 − at the same concentration (100 ng mL −1 ), and the changes in I pa (ΔI pa ) are presented in Fig. 8A . It shows that the values of ΔI pa upon the addition of BSA, Glu, L-Tyr, HGB, Na + , K + , Ca 2+ , Cl − and HCO 3 − are significantly lower than that upon the addition of anti-IgG, suggesting excellent selectivity of the MIP biosensor. The reproducibility is examined by the detection of 1.0 ng mL −1 anti-IgG with five MIP biosensors fabricated under the same conditions. As shown in Fig. 8B , the values of I pa vary little with a relative standard deviation (RSD) of 2.54%, demonstrating excellent reproducibility of the MIP biosensor. In addition, the MIP biosensor is stored at 4 °C for 3 weeks to evaluate its stability, and the results of the detection of 1.0 ng mL −1 anti-IgG are shown in Fig. 8C . After 2 and 3 weeks, the I pa can still remain 88.8% and 81.5%, respectively, of its initial value, suggesting good storage stability of the MIP biosensor. Finally, the practicability of the developed MIP biosensor is assessed by the detection of anti-IgG in serum sample by standard addition method (Table S2 in Supporting Information). The recoveries are in the range between 97.36% and 100.98%, demonstrating that the detection of anti-IgG in serum sample with the developed MIP biosensor is highly reliable. Although the developed MIP biosensor can be used for the accurate detection of anti-IgG, it still has two limitations: (1) the probe of [Fe(CN) 6 ] 3−/4− is necessary for the detection of anti-IgG in this work, and the design of label-free MIP biosensors is still needed to further enhance the sensitivity; (2) the MIP biosensor can be further improved to be used for point-of-care sensing, which has significant importance for medical diagnosis [35] . Accurate detection of protein biomarker plays an important role in the clinic diagnosis. Here, a surface imprinted biosensor based on boronate affinity is fabricated for the electrochemical detection of anti-IgG. The as-fabricated MIP biosensor shows high selectivity, reproducibility and stability when used for the detection of anti-IgG, and the practicability of the biosensor is also confirmed by the detection of anti-IgG in real serum sample. All these findings suggest that the developed MIP biosensor might be a promising and potential candidate for the sensing of anti-IgG, which is of great significance for future design of highly sensitive and selective anti-IgG biosensors. The online version contains supplementary material available at https:// doi. org/ 10. 1007/ s00604-022-05204-w. Funding The authors are grateful to the financial supports from the Science and Technology Program of Zhejiang Province (LGF22B050008), the Natural Science Foundation for Colleges and Universities in Jiangsu Province (20KJA150005) and the Advanced Catalysis and Green Manufacturing Collaborative Innovation Center (ACGM2016-06-27). The authors declare no competing interests. DNA-mediated strand displacement facilitates sensitive electronic detection of antibodies in human serums Vaccines and broadly neutralizing antibodies for HIV-1 prevention Evaluation of VIDAS(R) diagnostic assay prototypes detecting dengue virus NS1 antigen and anti-dengue virus IgM and IgG antibodies Quantum dots-based fluoroimmunoassay for anti-Zika virus IgG antibodies detection Monoclonal antibodies as immunomodulatory therapy against cancer and autoimmune diseases Clinical evaluation of an immunochromatographic-based IgM/IgG antibody assay (GenBody (TM) COVI040) for detection of antibody seroconversion in patients with SARS-CoV-2 infection Ultra-precise label-free nanosensor based on integrated graphene with Au nanostars toward direct detection of IgG antibodies of SARS-CoV-2 in blood Nanostructured molecularly imprinted polymers for protein chemosensing Recent advances in molecular imprinting technology: current status, challenges and highlighted applications A potentiometric protein sensor built with surface molecular imprinting method Fabrication of surface potein-imprinted biofuel cell for sensitive self-powered glycoprotein detection Specific recognition of proteins and peptides via controllable oriented surface imprinting of boronate affinity-anchored epitopes Rapid real-time detection of procalcitonin using a microcontact imprinted surface plasmon resonance biosensor Triethylenetetramine-grafted magnetite graphene oxide-based surfaceimprinted polymer for the adsorption of Ni(II) in food samples Preparation of molecularly imprinted polymers specific to glycoproteins, glycans and monosaccharides via boronate affinity controllable-oriented surface imprinting Affinity-tunable specific recognition of glycoproteins via boronate affinity-based controllable oriented surface imprinting A sensitive non-enzyme sensing platform for glucose based on boronic acid-diol binding A molecular-imprint nanosensor for ultrasensitive detection of proteins D-mannitol sensor based on molecularly imprinted polymer on electrode modified with reduced graphene oxide decorated with gold nanoparticles Sensing of glycoprotein via a biomimetic sensor based on molecularly imprinted polymers and graphene-Au nanoparticles Electrochemical sensors based on graphene materials Nonenzymatic glucose sensing by CuO nanoparticles decorated nitrogen-doped graphene aerogel A novel electrochemical sensing platform for detection of dopamine based on gold nanobipyramid/multi-walled carbon nanotube hybrids Abnormally large plasmonic shifts in silica-protected gold triangular nanoprisms Preparation of graphene oxide-based surface plasmon resonance biosensor with Au bipyramid nanoparticles as sensitivity enhancer Gold nanobipyramid-embedded silver-platinum hollow nanostructures for monitoring stepwise reduction and oxidation reactions An electrochemical sensor based on poly (L-Cysteine)@AuNPs@reduced graphene oxide nanocomposite for determination of levofloxacin Preparation and growth mechanism of gold nanorods (NRs) using seed-mediated growth method Comparison of photoluminescence quantum yield of single gold nanobipyramids and gold nanorods Electrochemical properties and sensing applications of nanocarbons: a comparative study Hierarchical mesoporous Co 3 O 4 /C@MoS 2 core-shell structured materials for electrochemical energy storage with high supercapacitive performance Non-enzymatic lactose molecularly imprinted sensor based on disposable graphite paper electrode Highly sensitive label-free electrochemical aptasensors based on photoresist derived carbon for cancer biomarker detection Electrochemical sensor for levofloxacin based on molecularly imprinted polypyrrole-graphene-gold nanoparticles modified electrode Sweat-based in vitro diagnostics (IVD): from sample collection to point-of-care testing (POCT)