key: cord-0757407-18ds7i7z authors: Nikolai, Olga; Rohardt, Chiara; Tobian, Frank; Junge, Andrea; Corman, Victor M.; Jones, Terry C.; Gaeddert, Mary; Lainati, Federica; Sacks, Jilian A.; Seybold, Joachim; Mockenhaupt, Frank P.; Denkinger, Claudia M.; Lindner, Andreas K. title: Anterior nasal versus nasal mid-turbinate sampling for a SARS-CoV-2 antigen-detecting rapid test: does localisation or professional collection matter? date: 2021-08-27 journal: Infectious diseases DOI: 10.1080/23744235.2021.1969426 sha: bfa5e73aae662629234873f0f03a918099e4235e doc_id: 757407 cord_uid: 18ds7i7z INTRODUCTION: Most SARS-CoV-2 antigen-detecting rapid diagnostic tests require nasopharyngeal sampling, which is frequently perceived as uncomfortable and requires healthcare professionals, thus limiting scale-up. Nasal sampling could enable self-sampling and increase acceptability. The term nasal sampling is often not used uniformly and sampling protocols differ. METHODS: This manufacturer-independent, prospective diagnostic accuracy study, compared professional anterior nasal and nasal mid-turbinate sampling for a WHO-listed SARS-CoV-2 antigen-detecting rapid diagnostic test. The second group of participants collected a nasal mid-turbinate sample themselves and underwent a professional nasopharyngeal swab for comparison. The reference standard was real-time polymerase chain reaction (RT-PCR) using combined oro-/nasopharyngeal sampling. Individuals with high suspicion of SARS-CoV-2 infection were tested. Sensitivity, specificity, and percent agreement were calculated. Self-sampling was observed without intervention. Feasibility was evaluated by observer and participant questionnaires. RESULTS: Among 132 symptomatic adults, both professional anterior nasal and nasal mid-turbinate sampling yielded a sensitivity of 86.1% (31/36 RT-PCR positives detected; 95%CI: 71.3–93.9) and a specificity of 100.0% (95%CI: 95.7–100). The positive percent agreement was 100% (95%CI: 89.0–100). Among 96 additional adults, self nasal mid-turbinate and professional nasopharyngeal sampling yielded an identical sensitivity of 91.2% (31/34; 95%CI 77.0–97.0). Specificity was 98.4% (95%CI: 91.4–99.9) with nasal mid-turbinate and 100.0% (95%CI: 94.2–100) with nasopharyngeal sampling. The positive percent agreement was 96.8% (95%CI: 83.8–99.8). Most participants (85.3%) considered self-sampling as easy to perform. CONCLUSION: Professional anterior nasal and nasal mid-turbinate sampling are of equivalent accuracy for an antigen-detecting rapid diagnostic test in ambulatory symptomatic adults. Participants were able to reliably perform nasal mid-turbinate sampling themselves, following written and illustrated instructions. Nasal self-sampling will facilitate scaling of SARS-CoV-2 antigen testing. Due to their short turn-around time and ease-of-use, antigen-detecting rapid diagnostic tests (Ag-RDTs) enable new testing strategies for SARS-CoV-2 [1, 2] . Currently, most SARS-CoV-2 Ag-RDTs require nasopharyngeal (NP) sampling, which is frequently perceived as uncomfortable and requires healthcare professionals, thus limiting scale-up. Nasal sampling could enable selfsampling and increase acceptability. The term nasal sampling is often not used uniformly and sampling protocols differ. The US Centres for Disease Control and Prevention (CDC) differentiates anterior nasal (AN) and nasal mid-turbinate (NMT) sampling [3] . Recent studies have demonstrated the equivalence of NMT-compared to NP-sampling for a WHO-listed SARS-CoV-2 Ag-RDT and the feasibility of self-sampling [4] [5] [6] . AN-sampling is easier and more convenient than NMT-sampling, but Ag-RDT performance with AN-sampling has not been evaluated. The objective of this prospective diagnostic accuracy study was a head-to-head comparison of professional AN-and NMT-sampling for a WHO-listed SARS-CoV-2 Ag-RDT. Furthermore, the accuracy and feasibility of self NMT-sampling were evaluated. This was a manufacturer-independent, prospective diagnostic accuracy study comparing two different nasal sampling methods for an Ag-RDT. From the first group of participants, professionally collected AN and NMT samples were taken. In the second group, each participant self-collected a NMT sample and underwent a professional NP swab ( Figure 1 ). The Ag-RDTs were performed directly after sampling at point-of-care by study physicians with a semi-quantitative visual read-out of the test band (categorized as negative, weak positive, positive, or strong positive) as described in a prior study [6] . The reference standard was real-time polymerase chain reaction (RT-PCR) using a combined oro-/nasopharyngeal (OP/NP) sample as described previously [6] . The study took place at the ambulatory SARS-CoV-2 testing facility of Charit e University Hospital between 30 November 2020 and 18 January 2021. Participants eligible for inclusion were adults with high clinical suspicion of SARS-CoV-2 infection. For self-sampling, a minimum CEFR (Common European Framework of Reference) language level of B2 (upper intermediate) in German or English was required. Participants were consecutively enrolled, according to laboratory capacity. The study was continued until at least 30 positive Ag-RDT results were obtained with each sampling method, which is the minimum recommended by the WHO Emergency Use Listing Procedure to demonstrate sample type equivalency [7] . The Ag-RDT evaluated was the STANDARD Q COVID-19 Ag Test (SD Biosensor, Inc. Gyeonggi-do, Korea), which is also distributed by Roche in Europe [8] . At the time of the study, the test was commercially available as NPsampling kit and only for research use as nasal-sampling kit (used for NMT and AN). Differences between the swabs and the procedures of the two test kits have previously been described [4] . Participants were asked to blow their nose once before sampling. Professional AN-and NMT-sampling followed the CDC guidance for SARS-CoV-2 testing [3] . For ANsampling, the tip of a swab was inserted into the nose vertically 1-1.5 cm and rotated against the nasal walls for 15 s in both nostrils. For NMT-sampling, while tilting the head back (70 ) the swab was inserted horizontally (parallel to the palate) into both nostrils for about 2 cm until resistance occurred, and then rotated 4 times against the nasal walls. Among consecutive participants, the sequence of AN-and NMT-sampling was alternated, followed by OP/NP-sampling for RT-PCR. Participants who underwent NMT self-sampling received written and illustrated instructions in German or English. For NMT self-collection, a timing of 15 s was specified in addition to the minimum of 4 rotations. Procedures were observed without answering questions or providing corrections. NMT self-sampling (both nostrils) was followed by professional NP-sampling (through one nostril) for Ag-RDTs and combined OP/NP-sampling (other nostril) for RT-PCR. User acceptability and feasibility of self-sampling were assessed by observer and patient questionnaires. The study included 132 participants with professional AN-versus NMT-sampling, and 96 who underwent self NMT-sampling versus professional NP-sampling ( Figure 1 ). Average age was 34.6 years (Standard Deviation [SD] 11.7) with 46.7% females and 20.3% having comorbidities. On the day of testing, 97.4% of participants had one or more symptoms consistent with SARS-CoV-2 infection. Average duration of symptoms at the time of presentation was 3.4 days (SD 3.0). Among participants performing self-sampling, 48 (50.5%) had a prior swab for SARS-CoV-2 been collected, and 50 (52.6%) had a higher education degree (Supplementary Table S1 ). third reader was necessary to agree on the interpretation of one NMT-result, which was ultimately considered negative, but turned out to be false negative based on a positive RT-PCR result. Deviations of self NMT-sampling included a more vertically-directed angle for sampling (n ¼ 13), incorrect depth (n ¼ 4 too superficial, n ¼ 10 too deep), and reduced swabbing intensity (regarding duration n ¼ 28, rotations n ¼ 12, and rubbing n ¼ 36 Among symptomatic outpatients, the sensitivities in detecting SARS-CoV-2 with an Ag-RDT were identical with professional AN-and NMT-sampling (86.1% overall; 96.6% at high viral load; 42.9% at low viral load). Furthermore, self NMT-sampling yielded the same sensitivity as professional NP-sampling (91.2% overall; 100% at high viral load; 66.7% at low viral load). Thus, our data suggests that AN-sampling is a suitable alternative to NMT-or NP-sampling. AN-and NMT-sampling protocols may overlap in practice and deviate in details [6] . Participants in this study blew their nose once, on the theoretical assumption that this may increase the virus concentration in Table 1 . Sensitivity, specificity, and percent agreements of A) professional AN-versus professional NMT-sampling, and B) self NMT-versus professional NP-sampling. The results are also differentiated by high and low viral load (!/< 7 log 10 SARS-CoV2 RNA copies/ml). the sampling region. Also, a timing of 15 s was specified for self NMT-sampling in contrast to other protocols [3] . The strengths of the study are the rigorous standardized sampling methods, two independent blinded readers, and an additional semi-quantitative visual readout of the Ag-RDT test band. A limitation of the study is that it was performed in a single centre. Participants were mainly symptomatic with a rather short duration of symptoms and in the majority with high viral load. This study demonstrates the diagnostic equivalence of the sampling methods for patients who are particularly infectious and responsible for transmission, however, it needs confirmation for asymptomatic patients and patients with low viral load. Patients who performed self-sampling were rather young and educated, half of whom already had experienced professional sample collection for SARS-CoV-2. In settings with different prevailing patient characteristics (e.g. less literate) a demonstration or oral instruction might be necessary for self-sampling. The clinical usefulness of nasal sampling has been demonstrated and acknowledged for SARS-CoV-2 RT-PCR, including self-sampling [9] [10] [11] , and evidence for Ag-RDTs is growing [4] [5] [6] 12, 13] . The use of dedicated nasal swabs for Ag-RDT is likely to be beneficial, as in an initial study the diagnostic accuracy of nasal sampling using a NP swab (smaller sampling surface, more flexible and more tickling) was slightly worse [5] . With written and illustrated instructions, patients were able to easily perform NMT-sampling. Nasal self-sampling will allow scaling of antigen testing. Considering the diagnostic equivalence, the more convenient self AN-sampling should allow an even broader use. This study was approved by the ethics committee of Charit e -Universit€ atsmedizin (EA1/371/20). European Centre for Disease Prevention and Control. Options for the use of rapid antigen tests for COVID-19 in the EU/EEA and the UK European Centre for Disease Prevention and Control. Surveillance of COVID-19 at long-term care facilities in the EU/EEA Interim Guidelines for Collecting, Handling, and Testing Clinical Specimens for COVID-19 Head-to-head comparison of SARS-CoV-2 antigen-detecting rapid test with professional-collected nasal versus nasopharyngeal swab Head-to-head comparison of SARS-CoV-2 antigen-detecting rapid test with self-collected nasal swab versus professional-collected nasopharyngeal swab Diagnostic accuracy and feasibility of patient self-testing with a SARS-CoV-2 antigen-detecting rapid test EUL) submission: In vitro diagnostics detecting SARS-CoV-2 nucleic acid and rapid diagnostics tests detecting SARS-CoV-2 antigens. Version 4 COVID-19 Ag STANDARDTM Q COVID-19 Ag Test Performance of saliva, oropharyngeal swabs, and nasal swabs for SARS-CoV-2 molecular detection: a systematic review and meta-analysis Swabs collected by patients or health care workers for SARS-CoV-2 testing The Infectious Diseases Society of America Guidelines on the Diagnosis of COVID-19: Molecular Diagnostic Testing Performance and implementation evaluation of the Abbott BinaxNOW Rapid Antigen Test in a high-throughput drive-through community testing site in Massachusetts Comparison of SARS-COV-2 nasal antigen test to nasopharyngeal RT-PCR in mildly symptomatic patients All raw data and analysis code are available upon request to the corresponding author. AKL, ON, and CMD designed the study and developed standard operating procedures. ON and CR implemented the study design and performed the laboratory work. AJ enrolled participants and supported the laboratory work. ON, CR, and AKL led the writing of the manuscript. FPM and JS coordinated and supervised the study site. FT and MG led the data analysis. FL provided technical advice. VMC and TCJ were responsible for PCR testing and contributed to the interpretation of the data. JAS supported the study design setup. All authors have reviewed the manuscript. No potential conflict of interest was reported by the author(s).