key: cord-0756978-0cfvwyt0 authors: Schaefer, Wolfgang M.; Knollmann, D.; Meyer, Philipp T. title: V/Q SPECT/CT in the Time of COVID-19: Changing the Order to Improve Safety Without Sacrificing Accuracy date: 2021-07-01 journal: J Nucl Med DOI: 10.2967/jnumed.120.261263 sha: 43229bcdca62a6d2aa048307bb845e5b7408ab10 doc_id: 756978 cord_uid: 0cfvwyt0 nan Essen, Germany E-mail: wolfgang.fendler@uk-essen.de Changing the Order to Improve Safety Without Sacrificing Accuracy TO THE EDITOR: Various nuclear medicine associations and colleagues (1-6) have discussed whether a ventilation examination should be included at all when performing ventilation-perfusion (V/Q) scans for diagnosis of pulmonary embolism during the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. This consideration was prompted by the concern that a ventilation scan may be an aerosol-prone maneuver and, thus, carry a potential risk of infecting the personnel. Usually, the V/Q scan procedure starts with a ventilation scan, which is followed by a perfusion scan and is eventually closed with a low-dose CT scan, if available. This sequence is traditionally chosen for a V/Q scan because it is easier to surpass the ventilation activity with the perfusion marker than vice versa. Instead of completely eliminating the ventilation scan, resulting in a reduction in specificity (7) and all its negative consequences-such as bleeding events due to unnecessary anticoagulation-we suggest modification of the workflow during the pandemic such that the scan routinely starts with perfusion SPECT (with a somewhat lower administered activity than usual, associated with an increased acquisition time) and proceeds with low-dose CT, if applicable. Ventilation SPECT (with a somewhat higher administered activity than usual, associated with a decreased acquisition time) would be performed only when there are perfusion deficits that are not sufficiently explained by structural findings on low-dose CT. If the patient is SARS-CoV-2-positive or there are COVIDlike findings on low-dose CT, it would remain at the discretion of the physician whether a ventilation scan is performed, under appropriate security measures. By doing so, we can reduce the number of ventilation scans and avoid the aforementioned discussion by various nuclear medicine associations and colleagues (1-6). Figure 1 shows a representative example of the proposed approach in a recently bedridden 80-y-old woman with dyspnea, thoracic pain, and an increased D-dimer level who was referred from an external hospital to rule out pulmonary embolism. We started by injecting about 45 MBq of 99m Tc-macroaggregated albumin and performing perfusion SPECT/CT. Since we found relevant perfusion deficits and unremarkable findings on low-dose CT, we subsequently also performed ventilation SPECT with about 88 MBq of 99m Tc-Technegas (Cyclomedica) (net ventilated activity calculated from the projection data). The ventilation and perfusion studies showed mismatched findings typical of pulmonary embolism (Fig. 1A) . In combination with the normal results from the low-dose CT examination (Fig. 1B) , these findings allowed us to detect pulmonary embolism with the highest degree of certainty, according to Gutte et al. (7) . Overall, we believe that the suggested routine reversal of the traditional workflow helps to minimize aerosol-prone and potentially infectious maneuvers without compromising the accuracy of pulmonary embolism diagnostics. Mapping prostate cancer lesions before and after unsuccessful salvage lymph node dissection using repeat PSMA PET Accuracy of 68 Ga-PSMA-11 for pelvic nodal metastasis detection prior to radical prostatectomy and pelvic lymph node dissection: a multicenter prospective phase III imaging study Detection rate of 18 F-choline PET/CT and 68 Ga-PSMA-HBED-CC PET/CT for prostate cancer lymph node metastases with direct link from PET to histopathology: dependence on the size of tumor deposits in lymph nodes Single lesion on prostate-specific membrane antigen-ligand positron emission tomography and low prostate-specific antigen are prognostic factors for a favorable biochemical response to prostate-specific membrane antigen-targeted radioguided surgery in recurrent prostate cancer Prostate Cancer Molecular Imaging Standardized Evaluation (PROMISE): proposed miTNM classification for the interpretation of PSMA-ligand PET/CT Diagnostic evaluation of pulmonary embolism during the COVID-19 pandemic COVID-19 and ventilation/perfusion (V/Q) lung studies Recommandations pour la r ealisation de la scintigraphie pulmonaire dans le contexte d' epid emie due au virus Covid-19 COVID-19: guidance for infection prevention and control in nuclear medicine Clinical utility of perfusion (Q)-single-photon emission computed tomography (SPECT)/CT for diagnosing pulmonary embolus (PE) in COVID-19 patients with a moderate to high pre-test probability of PE Single photon emission computed tomography lung perfusion imaging during the COVID-19 pandemic: does nuclear medicine need to reconsider its guidelines Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography wolfgang.schaefer@mariahilf.de Published online