key: cord-0756591-v1qjm4cx authors: nan title: Abstracts: PICS-AICS Virtual Symposium September 10–12, 2020 date: 2020-07-31 journal: Pediatr Cardiol DOI: 10.1007/s00246-020-02408-w sha: 319a654d23d67049bcbcbb2ace7f0a9acbc02887 doc_id: 756591 cord_uid: v1qjm4cx nan complexity of the procedure and could increase the complication rates especially embolization. We describe the imaging planes in a case of secundum ASD with juxtaposed atrial appendage that was successfully closed using an Amplatzer septal occluder. An 11-year-old female with a diagnosis of secundum ASD and juxtaposition of the atrial appendage underwent successful deployment of a 18-mm Amplatzer septal occluder with the help of TEE guidance. The atrial septal orientation was clearly ascertained using orthogonal planes and 3D data sets as there is a great potential to misconstrue the mouth of the juxtaposed appendage to be the defect thereby minimizing the risk of embolization. Conclusion: The lie of the atrial septum is altered significantly in the presence of juxtaposition of atrial appendage. Appropriate delineation of the plane of the septum by TEE and 3D data sets is important to get the appropriate angles in order to successfully deploy the septal occluder. 7 Hypoxemia Following Balloon Pulmonary Valvuloplasty for Critical Pulmonary Stenosis Rajiv Devanagondi, Glenn Leonard University of Rochester Medical Center, Rochester, USA Abstract Background: Infants with critical pulmonary valve stenosis (PS) require augmented pulmonary blood flow by maintaining ductal patency to establish normal oxygen saturation. Balloon pulmonary valvuloplasty effectively treats critical PS. However, some infants require prolonged supplemental oxygen post catheterization to maintain normal oxygen saturation due to decreased compliance of the hypertrophied right ventricle, and increased right-to-left atrial level shunt. Supplemental oxygen duration post procedure, and factors associated with prolonged oxygen treatment, have not been described previously. Methods: Catheterization, echocardiogram, and progress notes were retrospectively reviewed for all patients following balloon pulmonary valvuloplasty for critical PS between 1/1/2000 and 3/1/2019. Patients with additional congenital heart disease (apart from PFO or small ASD) were excluded. Supplemental oxygen was continued post procedure to maintain resting oxygen saturation [ 88% by pulse oximetry, though intermittent, self-resolved desaturations to 80% were not treated with additional oxygen. Data were reported as n (%) and median (IQR or range). Continuous variables were compared using Wilcoxon ranked-sum test. Categorical variables were compared using Fisher's exact test. p \ 0.05 was considered statistically significant. Results: Twenty-six infants had balloon pulmonary valvuloplasty at age 2 (1-5) days with weight 3.4 (2.8-3.8) kg. Four (15%) were premature. Eleven (42%) needed supplemental oxygen pre-catheterization including 4 (15%) that were intubated. By echocardiogram, baseline right ventricle (RV) to pulmonary artery (PA) peak gradient (PG) was 82 (69-93) mmHg, pulmonary valve diameter 7 (6.5-7.9) mm and Z-score -1.6 (-1.9 to -0.5), and tricuspid valve diameter 12. 1 (10.5-13. 2) mm and Z-score ?0.3 (-1 to ?0.8). Seven (37%) had C mild RV systolic dysfunction, 2 (8%) had mild RV hypoplasia, and 11 (42%) had C mild RV enlargement. The baseline RV-PA PG by catheter was 61 (45-73) mmHg and baseline RV/systemic pressure ratio 1.5 (1.3-1.8) . Following valvuloplasty, RV-MPA PG was reduced to 15 (12-20) mmHg and RV/systemic pressure ratio 0.8 (0.6-0.9). Prostaglandin duration post procedure was 1 (0-2.3) days and oxygen supplementation was 1 (range: 0-15) day, with 8 patients receiving C 5 days supplemental oxygen prior to hospital discharge. Two (8%) patients were discharged home with supplemental oxygen. Infants with C 5 days supplemental oxygen post-procedure had smaller tricuspid valve diameter (10.4 vs. 13 mm, p = 0.03), and increased baseline RV/systemic pressure ratio (1.7 vs. 1.4 , p = 0.04). There were no other statistically significant differences between groups and specifically lower gestational age, need for oxygen or intubation pre-valvuloplasty, smaller pulmonary valve diameter, greater post-procedure RV-PA PG, and RV dysfunction were not associated with longer duration of supplemental oxygen post-valvuloplasty. No patient had additional transcatheter or surgical procedures prior to discharge. Conclusions: Balloon pulmonary valvuloplasty effectively treats critical pulmonary stenosis, though the duration of post-procedure Pediatr Cardiol oxygen supplementation is highly variable, from 0 to 15 days in this series. Patients with smaller tricuspid valves and increased RV pressure at baseline were more likely to have a prolonged oxygen requirement post procedure. 8 Short-Term Outcomes Of Percutaneous Device Closure of Patent Ductus Arteriosus Using The Amplatzer Duct Occluder Device in Comparison To The Nitoccluder PDA-R Device diameters across aortic annulus, STJ, and sinus of Valsalva were larger in the dilated unrepaired group with mean and median of 24.63 (3.99) and 25 (15-35), 27.2 (4.26) and 27 (17-40), 35.97 (4.59) and 36 (24-45) mm, respectively, compared to a mean and median of 13.2 (2.62) and 13 (9-17), 14.53 (2.90) and 14 (10-19), 20.53 (3.40) and 21 (14-25) mm, respectively, in the not dilated unrepaired group with significant statistical difference (p value \ 0.0001). Also Z-score among unrepaired dilated TOF patients at the level of annulus, STJ, and sinus of Valsalva was larger in comparison to the non-dilated unrepaired group with significant statistical difference (p value \ 0.0001). Conclusions: The first important finding of this study is the occurrence of significant aortic root dilatation in 22% of patients after intracardiac repair of TOF. Older age at repair, long shunt to repair interval, and residual ventricular septal defect are the most common variables associated with aortopathy and aortic regurgitation in such group of patients. The second important finding is the occurrence of aortic root dilatation in 70% of patients before surgical repair of TOF; whereas male sex and TOF with pulmonary atresia appeared to be the most common variables associated with aortopathy and aortic regurgitation in this group of patients. Keywords: Tetralogy of Fallot, Aortopathy, Ventricular Septal Defect, Aortic Regurgitation, Pulmonary Regurgitation, Pulmonary Atresia 11 Radiation Savings in Heart Transplant Patients Using MR-Guided Right-Heart Catheterization Technique Jennifer Schramm, Ileen Cronin, Laura Olivieri, Tacy Downing, Joshua Kanter Children's National Hospital, Washington, USA Abstract Background: Lifetime radiation exposure for heart transplant patients is significant due to need for ongoing surveillance biopsy and coronary angiography. Magnetic resonance (MR)-guided right-heart catheterization (RHC) uses rapid MR image acquisition and reconstruction to aid catheter manipulation, eliminating radiation exposure from the hemodynamic catheterization. However, the magnitude of radiation reduction is unknown. The aim of this study is to understand the typical radiation reduction associated with MR-guided RHC and to quantify the additional contribution from x-ray-guided endomyocardial biopsy (EMB) and coronary angiography. Methods: This is an IRB-approved, retrospective review of patient radiation exposure during surveillance catheterization in 16 transplant patients. Twenty-four MR-guided RHC procedures were weight and age matched with 24 controls with non-complex, 4-chamber circulations who underwent x-ray-guided RHC. Radiation doses for EMB and coronary angiography were also collected from the MR-guided RHC group. The average dose area product (DAP) per kg was calculated and effective dose was estimated using previously published conversions. Results: The median radiation exposure for an x-ray guided RHC was 0.4 uGy*m 2 /kg (range 0.05-3.3). When converted to effective dose, the median total dose was 0.07 mSv (0.006-0.4). In the MR-guided RHC cohort, where patients underwent EMB only (n = 9), a median of 1.06 uGy*m 2 /kg (0.2-12) or 0.2 mSv (range 0.02-2) of exposure occurred. In the same cohort for patients who underwent EMB with coronary angiography (n = 15), there was a median of 26.0 uGy*m 2 / kg (9-82) or 4.0 mSv (range 1.3-10.6) of exposure. Conclusions: MR-guided RHC is increasingly used to improve visualization and decrease radiation exposure in patients requiring cardiac catheterization. However, the absolute radiation reduction of MR-guided hemodynamics is minimal. In this population, at least 55 MR-guided RHCs would be required to offset the radiation exposure from one annual coronary catheterization. Research efforts should focus on developing MR-conditional equipment for EMB and coronary angiography. Objectives: The aim of this study was to evaluate the diagnostic utility of cardiac catheterization and the efficacy of transcatheter intervention in patients with hemoptysis. Background: Cardiac catheterization may play a role on identifying the etiologies of hemoptysis with the potential for transcatheter intervention. Methods: This was a retrospective study of all the patients who were brought to the pediatric cardiac catheterization laboratory for the indication of hemoptysis over a 15-year period (2006-2020) . Results: Twenty-one patients underwent 28 cardiac catheterizations. The median age was 17.4 years (range 0.3 to 60.0), and the underlying cardiac diagnoses were normal heart n = 3, pulmonary hypertension 1, heart transplant 1, pulmonary arteriovenous malformation 1, pulmonary vein disease 3, biventricular congenital heart diseases 5, and single ventricles 7. The diagnostic utility of catheterization was 81% (17/21). At two-thirds (18/28) of catheterizations, transcatheter interventions were performed in 14/21 (67%) patients: aortopulmonary collateral embolization 14, aortopulmonary and venovenous collateral embolization 1, and pulmonary arteriovenous malformation embolization 3. Although recurrent hemoptysis was frequent (50%) post intervention, the final effectiveness of transcatheter interventions was 79% (11/14 patients). Overall mortality was 19% (4/21), all in those presenting with massive hemoptysis. Conclusions: Cardiac catheterization was shown to have good diagnostic utility for hemoptysis especially in patients with underlying congenital heart disease. Despite the high mortality and recurrent hemoptysis rate, transcatheter interventions was effective in our cohort. Patients and Methods: Between January 2018 and December 2019, ninety-six patients with duct-dependent pulmonary circulation underwent PDA stenting as first palliative procedure. Post-procedure follow-up was done by clinical evaluation, assessment of Sao2, and echocardiography evaluation for the stent patency and the size of the pulmonary arteries. These parameters were compared with baseline values. Results: The median age of 96 patients was 22 (2-120) days and their median weight was 3 (2-5.5) kg. The procedure was successful in 81.25% of patients, 72.92% has tortuous PDA. The femoral artery approach was used in 75% of procedures, axillary access in 19.79%, carotid access in 3.8%, and femoral vein approach in 2.6%. Seventynine coronary stents were deployed in 78 patients. One patient needs two stents to cover total ductal length, and drug-eluting stent was used in 17 (21.8%) patients. Median right PA (RPA) and left PA (LPA) Z-scores were -0.79 (-1.91 to 0.12) and -1.02 (-1.82 to -0.38), respectively. The success rate was higher in straight PDA and in relatively younger patients. Post-stenting mean oxygen saturation (SO 2 ) increased significantly from baseline. No mortality was reported during the procedure. Minor complications in seven patients, while stent thrombosis in two patients and stent embolization in another two. At a median follow-up (4-6) month for 43 patients, MSCT was done for 37 patients, median RPA and LPA Z-scores, [0. 93 (0.28-1.82 ), 0.40 (0.24-1.01)], respectively, were significantly increase compared to baseline. Four patients required reinterventions. Eighteen patients underwent cardiac surgery during the follow-up period. Urgent BT shunt was done for six patient, palliative surgery was done for nine, and corrective surgery for three patients. Conclusion: Ductal stenting is an effective palliative procedure for patients with duct-dependent PBF. It maintains adequate SO2 and promotes balanced PA growth at mid-term follow-up. Keywords: Duct-dependent pulmonary circulation, PDA stenting, Approach, Outcome 14 Silent Patent Ductus Arteriosus, Shall We Treat? Saif Aljemmali, Sawsan Awad Rush University Medical Center, Chicago, Illinois, USA Abstract Introduction: Hemodynamically insignificant patent ductus arteriosus (PDA) defined as PDA that does not cause congestive heart failure or left atrium and left ventricle dilation. Hemodynamically insignificant PDA can produce turbulent high-velocity flow across its lumen, thereby increasing the risk of bacterial endarteritis. Therefore, the majority of pediatric cardiologists recommend closure of hemodynamically insignificant PDAs that produce an audible murmur. However, closure of non-audible small PDAs remains controversial. Purpose: This study aims to evaluate the current general management of non-audible patent ductus arteriosus (PDA) that persists beyond infancy. We hypothesize that non-audible hemodynamically insignificant PDAs have turbulent high-velocity blood flow passing through them more or less similar to audible PDAs, therefore, carrying the same risk for developing infective endarteritis. Methodology: This is a retrospective chart review of all pediatric patients C 9 months of age with hemodynamically insignificant PDAs in the period between July 2009 and July 2019 at Rush University Medical Center. Patients were divided into audible PDA group and non-audible PDAs group. Flow velocity, aortic, and pulmonic diameters of PDAs were examined and compared in both groups. Results: Fifteen patients were included. Ten patients (* 67%) had non-audible hemodynamically insignificant PDAs, and five patients (* 33%) had audible hemodynamically insignificant PDAs. There were no statistical differences between flow velocities, aortic, and pulmonic diameters of non-audible PDAs versus audible PDAs (p value = 0.12, 0.07, and 0.52, respectively). Conclusion: Hemodynamically insignificant PDAs, whether audible or non-audible, have the same risk stratification of developing infective endarteritis and should have identical ways of management. Catheter Intervention as a Palliative procedure in Children and Adolescents with Pulmonary Hypertension Amal El-Sisi, Mohamed Samir, Mohamed Mossad Cairo University Children Hospital, Cairo, Egypt Abstract Pulmonary Hypertension is defined by a threefold condition: a mean PAP of 20 mmHG, a LAP lower than 15 mmHG, and a PVR of 3 Wood units. A lot of progress has been achieved when it comes to medications allowing for longevity and a better quality of life for PH patients; however, these medications are not curative. Interventions are also palliative as patients would eventually need lung or heartlung transplants. Interventions include septostomies or stenting the interatrial septum. More recently, reversed Potts shunts-both surgical and transcatheter-have also been performed on PH patients. Other PH interventions can be applied for cases of univentricular repair such as Glenn and Fontan procedures. These may include blocking extra-pulmonary blood supply, or interrupting forward flow, using plugs or other devices. For Fontan cases, circulation opening and stenting the closed fenestration can also help, especially when Fontan intervention fails. Interventions in PH in children and adolescents are not common. We report 20 cases who experienced different interventions for PH, with an age range of 9-25 years old and 75% female patients. Of the 20, 10 had idiopathic Ph, 4 were post Glenn, 2 post PA band, and 4 post Fontan. Interventions include balloon dilatation of IAS (6), stent IAS (3), Stent ASD device (1) , Shunt occlusion (2), Stent PDA coil (1) , PDA occlusion (1) , and forward flow interruption (6). Follow-up of idiopathic PH group revealed an overall improvement in symptoms and an increased desaturation. As for the univentricular heart group, symptoms also improved and more prominently, these cases exhibited a drop in PH. Through these cases, we conclude that intervention for PH in children and adolescents is a safe and feasible palliative procedure, which improves symptoms in PH for both idiopathic and postsurgery univentricular heart patients. Aim of the Study and Methodology: Two years of retrospective registry for the patient underwent left main stenting in Fattouma Bourguiba University Hospital Cardio B Department are investigated regarding the procedure and provisional vs 2-stent technique, which technique is used in bifurcation stenting. Results and Discussion: The patients were males (80%), diabetics (50%), and radial access was used in 60% in of cases with no significant bleeding complications either from Femoral or Radial access. The left main was affected ostially in 70% of cases and was treated by stenting while in 30% the left main was affected distally and also was treated by stenting. The patients were presented by anterior myocardial infarction in 40% of cases, while NON-STEMI in 40% of cases. In 30% of cases, the patients were stented in other sites than left main before stenting in the left main also 10% were stented in the left main before and we faced in-stent restenosis and were treated by stenting with excellent result and follow-up in clinic. In 10% of cases we treated by using 2-stent technique (TAP) technique and 90% were treated by 1-stent provisional stenting with TIMI III Flow in both LAD and LCX. We had 1 case died on table which was presented by anterior myocardial infarction thrombolysed 8 h after presentation arrested after stenting and died on table 40% of cases were treated by pre-dilation before stenting while 60% undergone as direct stenting with excellent TIMI III distal flow. 50% of cases had post-dilatation after stenting with excellent TIMI III distal flow. 30% of cases were treated by Sirolimus-eluting stents while 70% were treated by Everolimus-Eluting stents with excellent follow-up for all cases in our outpatient clinic. Conclusion: Left main stenting is uprising method for treatment of left main stenosis vs CABG. The second-generation drug-eluting stents are willing regarding TLR and MACE with less bleeding complication in radial and femoral access. Herein we report successful device closure of large-sized OS ASD in 59 children with less than 1 year of age done over the period of 9 years. The study population age and weight ranged from 7 to 12 months and 5.7 to 10.3 kg. Symptomatic children with dilated right heart were taken as criteria for the device closure. The sizes of the devices used were from 10 to 22 mm with high rate of successful deployment (97%). All patients who underwent successful device closure tolerated the procedure well without any major complications Introduction: Device closure of OS ASD in younger children with larger defects is a challenging task in view of requiring larger-sized sheaths and devices and thin pliable rims compared to older children. The size of the defects more than 8 mm are categorized large-sized defects. Materials and Methods: Fifty-nine children (male 30 and female 29) with age group of 7 months to 1 year and the weight ranged from 5.7 kg to 10.3 kg were included in our study population. We used Amplatzer septal occluder and delivery system in all our cases. All the devices were deployed using mostly left and in some cases right upper pulmonary venous approach under the guidance of TTE, TEE, and fluoroscopy. In 20 out of 59 children, we did not use TEE. Results: Out of 61 children taken for the device closure of ASD, 2 children did not undergo the procedure due to failure to position the device. Fifty-nine patients had successful device closure. Discussion: We had to up size the device in 5 and downsize in 2 patients after we found the device were mismatched on fluoroscopy. This was probably due to difficulty in identifying the thin atrial septal rims in echocardiogram. During the procedure none experienced major complications. But few patients developed premature atrial complexes and two cases had atrial bigeminy which subsided within 12 h of the procedure. The sizes of the devices selected were 2 to 3 mm more than the actual defect size measured by either TTE or TEE. The sizes of the devices used ranged from 10 to 22 mm. Out of 59 patients, 18 patients received 10 to 14 mm, 29 patients received 16 to 20 mm, and 2 patients received 22 mm devices. The patients were discharged from the hospital in the next day with dual antiplatelets. Advantages in early closure: 1. Thin and floppy margins were our concerns but all had successful deployment. Delayed intervention resulted in unsuitable for device closure due to resorption of thin margins especially IVC rim. there by saving the total cost of treatment. 3. 3. Low risk of complications with experienced operator. Conclusion: Since the transcatheter closure of ASD is feasible, relatively safer, and cheaper in children less than 1 year of age, there is no need of delaying the closure of the large-sized ASDs to the later age. Unexpected Complication of Fontan Operation Causing Cyanosis, and Impaired Coronary Circulation Jacek Kusa 1,2 , Pawel Czesniewicz 2 , Magdalena Slupska 2 1 Pediatric Cardiology Department, Medical University of Silesia, Katowice, Poland. 2 Pediatric Cardiology Department, Regional Specialized Hospital-Research and Development Centre, Wroclaw, Poland Abstract Background: Patients after Fontan procedure sometimes develop extremely rare complications, most of which can be treated in the cathlab. Materials and Methods: The 9-year-old boy after Fontan completion 7 years earlier, percutaneous closure of fenestration and aortopulmonary collateral (in 4th and 6th year of life, respectively) was admitted to our hospital due to increasing desaturation (from 98 to 88%) and worse exercise tolerance with increasing fatigue. ECG revealed ST-segment elevation in precordial leads. In the performed angiographic and hemodynamic examination, the properly functioning Fontan circulation was confirmed, but at the same time the presence of a fistula between the extracardiac tunnel and the coronary sinus was revealed. Fistula had a diameter of 4.5 mm and a length of 14 mm. It connects to the coronary sinus through a network of numerous vessels. Blood flow from the fistula caused stasis of blood in the coronary circulation. The procedure was performed under general endotracheal anesthesia, through femoral vein access. The right coronary Judkins catheter was used to enter to the ostium of fistula. The manual angiography was Pediatr Cardiol performed to confirm the previous diagnosis and establish the morphology precisely. Then the catheter was inserted deeper, but just before the coronary sinus. Through the same catheter the Amplatzer Vascular Plug 4-7 mm was introduced and released from delivery system. The right position of the implant was confirmed. Over the next 3 days the infusion of heparin was maintained, and then acenocoumarol was introduced with the recommendation lifetime use. Results: During follow-up, the increase of arterial saturation till 97% was observed and normalization of ST-segment in all leads was found. The physical efficiency improved significantly. Conclusions: The appearance of new symptoms of unknown etiology in patients with Fontan circulation should always be an indication for cardiac catheterization. In most cases, it is possible to find the source of the cyanosis and percutaneously close it. Some abnormal vascular connections can also lead to coronary ischemia, which can be easily treated in the same way. Results: A total of 195 patients underwent SCPA during the study period, 120 (61.5%) were male. One hundred and twelve patients (57.4%) had single right ventricle, 57 patients (29.2%) had single left ventricle, and 26 patients (13.3%) had two ventricles that could not be separated. Bilateral superior vena cava (SVC) was found in 24 patients (12.3%) and interrupted inferior vena cava was found in 7/195 (3.5%). In the interstage period, 51 patients (26.2%) underwent at least one additional cardiac catheterization, 32/51 (62.7%) required an intervention. During pre-SCPA cardiac catheterization, 28/194 patients (14.4%) underwent an intervention, the median mean PA pressure was 14 mmHg (9-24 mmHg) with a median transpulmonary gradient of 7 mmHg (2-19 mmHg), the median single ventricle enddiastolic pressure was 9 mmHg (4-19 mmHg), the median SVC and systemic saturations were 51% (26-75%) and 78% (45-94%), respectively. The median age and weight at the time of SCPA were 166 days and 6.2 kg, respectively. The median post-SCPA length of stay (LOS) was 8 days with 3% early mortality (6/195). Thirty-two patients (16.4%) underwent 43 post-SCPA catheterizations, 5 patients had 2, 1 patient had 3, and 1 patient had 4 catheterizations. The median postoperative day when the first catheterization was performed was 6.5 days (1-90 days) . The indications were hypoxia in 32 patients, persistent pleural effusions in 11 patients, hemodynamic instability requiring ECMO support in 3 patients, aortic arch obstruction in 2 patients, SVC syndrome in 1 patient, and over circulation due to an additional aortopulmonary shunt in 1 patient. Five procedures were hemodynamic evaluation only. Fifty interventions were performed, the most common interventions were pulmonary artery stent angioplasty (40%), pulmonary artery balloon angioplasty (20%), aortic arch balloon angioplasty (12%), venovenous collateral occlusion (10%), and aortopulmonary collateral occlusion (6%). Patients were divided into two groups with (group A) and without (group B) early postoperative catheterization. Group A had longer post-stage 1 LOS (mean 43 vs 28 days, p = 0.05), additional catheterizations in the interstage period (43% vs 22.7%, p = 0.01), and lower pre-SCPA SVC saturation (mean 46% vs 51%, p \ 0.01). At the time of SCPA, group A was younger (mean 162 vs 199 days, p \ 0.01) with lower weight (mean 5.8 vs 6.4 kg, p = 0.03) and longer cardiopulmonary bypass time (126.9 vs 91.6 min, p \ 0.01). Conclusions: Early post-SCPA cardiac catheterization is common. Several interesting characteristics were found to be significantly different in patients who required early catheterization. Spontaneous closure of PDA after unsuccessful transcatheter attempts to close PDA in preterm babies Ahmed Deniwar, Duraisamy Balaguru Division of Pediatric Cardiology. University of Texas McGovern Medical School at Houston, Houston, USA Abstract Background: Patent ductus arteriosus (PDA) is much more common in preterm infants, due to multiple factors. Transcatheter closure of PDA in preterm babies is increasing after approval of Amplatzer Piccolo device in the United States. We report two babies in whom spontaneous closure of PDA occurred after unsuccessful transcatheter closure attempts. Case summary: Patient 1 is 3-month-old, ex-28-week preterm girl. Current weight 3.5 kg. The PDA was tubular (Type C) with diameter 4.4 mm. Amplatzer Piccolo 5-4 device was placed in PDA. Overnight, baby remained intubated and sedated using Dexmedetomidine. Next morning, chest X-ray, Echocardiogram, and CT scan confirmed embolization of device to left pulmonary artery (LPA). Repeat catheterization was performed and the embolized device was retrieved. Amplatzer duct occlude device (6/4) was deployed, but was also removed due to unsatisfactory position. Decision was made not to pursue further attempts at transcatheter PDA closure. Echocardiogram next morning showed a much smaller PDA and repeat echocardiogram 5 days later showed complete closure of PDA. (There has been a follow-up echocardiogram before discharge that showed closed PDA). Patient 2 is 5-week-old ex-28-week preterm boy. Current weight 1.26 kg. Multiple dysmorphic features led to diagnosis of Cornelia de Lange syndrome. By angiogram, PDA was type F (Hockey-stick shape) with diameter 4 mm. Amplatzer Piccolo Occluder (5-2) device was deployed. After echocardiographic confirmation, the device was released. Upon release, the device was noted to move back into main pulmonary artery (MPA). Therefore, attempts were made to retrieve the device using gooseneck snare. During these attempts, the device dislodged to LPA and pericardial effusion occurred. After pericardiocentesis, there was immediate recurrence. Sternotomy was performed and a perforation in RVOT was repaired. Next morning, echocardiogram showed no PDA, device in proximal LPA with mild LPA stenosis only. At 4 months after procedure, device is still in MPA/LPA junction with mild LPA stenosis. Discussion: We are presenting two preterm babies who had unsuccessful attempts at transcatheter device closure of PDA and subsequently found to have spontaneous closure in both babies-one in 5 days and the other within 24 h. We speculate that mechanical stimulation of wall of PDA by the devices may initiate a process of Pediatr Cardiol spontaneous PDA closure. Other mechanisms for spontaneous closure of the PDA after birth including high pO 2 and low circulation prostaglandin have been proposed. Further studies are required to delineate the mechanism of spontaneous closure. Transcatheter Mitral Valve-in-Valve Implantation with an Edwards SAPIEN 3 Valve in an Adult with Congenital Heart Disease Heike Schneider, Claudius Jacobshagen, Thomas Paul, Claudia Dellas University Medicine Goettingen, Goettingen, Germany Abstract Transcatheter valve-in-valve (ViV) implantation has emerged as an alternative treatment option to repeat surgical replacement in highrisk patients for degenerated bioprosthetic valves. But data regarding these procedures in adults with congenital heart disease (ACHD) remain limited. We present the case of a 60-year-old lady born with a partial atrioventricular septal defect that was surgically corrected at the age of 7 years. Left-sided AV-valve replacement was performed for significant left-sided AV-valve stenosis and moderate regurgitation with a bioprosthetic valve (CE Perimount Modell Magna Mitral ease (25 mm) at the age of 54 years. The bioprosthesis was favored over mechanical valve replacement because of systemic lupus erythematosus with cerebral vasculitis and increased risk for cerebral bleeding to avoid long-term anticoagulation with a vitamin K antagonist. The patient was kept on 100 mg ASS once daily. Comorbidities included arterial hypertension, chronic renal insufficiency, moderate aortic stenosis, and regurgitation. Five years later, the patient complained about dyspnea and decreased exercise tolerance due to severe stenosis of the bioprosthesis with a mean echocardiographic gradient of 12 mmHg. Because of high-risk for open-heart surgery transcatheter ViV implantation was favored. Cardiac catheterization was performed under general anesthesia, heparin was given to achieve an ACT [ 200 ms and cephazolin was administered intravenously as prophylaxis. Transseptal puncture guided by TEE was followed by balloon dilation of the intraatrial septum with an 8 mm Atlas balloon. Under 3D-TEE guidance the stenotic mitral valve was crossed, and a 'Safire' wire was placed into the LV apex. To allow unhindered ViV implantation, the stenotic calcified bioprosthetic valve was predilated with the ES balloon. By previous CT evaluation and using the App 'ViV Mitral,' it was decided to implant a 26 mm ES 3 valve. This was subsequently performed without any problems. The 26 mm ES 3 valve was placed in good position, there was no insufficiency and the mean gradient was reduced to 3 mmHg post implant. Postinterventional atrial fibrillation was successfully cardioverted and gastric bleeding required gastroscopic clipping and transfusion. Anticoagulation was changed from initial dual antiplatelet therapy to apixaban 5 mg bid. At 3 months of follow-up, the patient's clinical status has improved significantly and the mean gradient across the ES 3 valve remained between 3 and 4 mmHg. Conclusion: Transcatheter mitral ViV implantation may be a good option in selected high-risk ACHD patients with good short-term results and low complication rate. Long-term data of transcatheter atrioventricular ViV implantation, originally developed for the aortic position, are still lacking. Successful Transcatheter Balloon Valvuloplasty of Previously Placed Transcatheter Pulmonary Valve Years After Initial Placement: A Report of 2 Cases Andrea Otero Luna, Britton Keeshan, Jeremy Asnes Yale University, New Haven, USA Abstract Background: Transcatheter pulmonary valve replacement (TPVR) is currently an accepted technique to treat conduit and bioprosthetic valve failure. Residual or progressive gradient across the transcatheter valve is thought to be a risk factor for development of bacterial endocarditis and RV dysfunction. Outcomes of balloon valvuloplasty years after initial TPVR to address residual stenosis are unknown. Methods: We report our recent experience in 2 patients with moderate to severe obstruction across the Melody valve who underwent successful balloon valvuloplasty after more than 4 years from initial implantation Results: Two patients were included in this series. Patient one was 14 years old with VACTERL sequence and pulmonary atresia, VSD, confluent central pulmonary arteries, and right aortic arch. Initial palliation included a central shunt when he was 6 days old with subsequent Rastelli procedure with VSD closure and RPA augmentation when he was 6 months old. At 30 months, patient had RV-PA conduit replacement with 17 mm aortic homograft for severe conduit obstruction. Patient developed moderate conduit obstruction and at 5 years of age, patient underwent successful TPVR with an 18 mm Medtronic Melody Valve following pre-stenting. There was no residual gradient across Melody valve following TPVR. Overtime the patient developed progressive stenosis across the valve consistent with somatic growth with multiple admissions for aspiration pneumonia and bacterial endocarditis rule-outs. At 14 years old, there was moderate stenosis by echocardiogram (peak 32 mmHg, mean 19 mmHg) and decision was made to perform balloon valvuloplasty. Patient underwent successful valve expansion up to 22 mm with an excellent result. There was trivial pulmonary insufficiency by intracardiac echo and no residual gradient. There were no complications. Patient two was a 13-year-old patient with complete atrioventricular canal defect with tetralogy of Fallot who underwent complete surgical repair in the newborn period with VSD closure and a transannular patch. He subsequently developed recurrent stenosis in his right ventricular outflow tract and had repeat surgical intervention at 4 months old. He developed progressive stenosis across his RV outflow tract patch and underwent successful TPVR with 18 mm Medtronic Melody valve at 7 years old following pre-stenting with 5 mmHg residual gradient at end of procedure. Four years later he was noted to have severe stenosis across the Melody valve (peak 70 mmHg, mean 38 mmHg). The Melody valve was subsequently balloon dilated using a 20 mm high-pressure balloon with resultant 2 mmHg gradient and mild Melody valve insufficiency. There were no complications. Conclusion: Successful balloon valvuloplasty of melody valve is feasible even after 9 years from initial implantation of the Melody valve without complications or significant valve compromise. Pulse Loss After Cardiac Catheterization in Infants: Does Sheath Size Matter? Kaitlin Swanson, Jillian Gorski, Mark Hoyer, Michael Ross, Ryan Alexy Indiana University, Indianapolis, USA Abstract Objective: The aim of this study was to review the prevalence of pulse loss in infants after cardiac catheterization at our institution, and to understand the benefit, if any, of using small 3.3 French sheaths in this population. Methods: A retrospective cohort study including all infants 0-12 months of age who had a cardiac catheterization with femoral arterial access at our institution between January 2015 and June 2019 was performed. Variables included patient age, weight, case duration, and size of arterial sheath. The primary outcome was clinical pulse loss. Secondary outcomes included treatment with heparin and diagnosis of an arterial thrombus. We used Fisher's Exact and Chisquared tests for comparing the incidence of our binary outcomes, clinical pulse loss, and heparin administration, among the different sheath sizes. We performed multiple logistic regression analyses, examining the association of variables with each outcome of interest. Results: 401 patients under 12 months old were analyzed. The prevalence of clinical pulse loss was 14.9%; 6.5% were treated with a heparin bolus, 11.2% had an ultrasound performed for persistent pulse loss, and 7.5% were diagnosed with a femoral arterial thrombus by ultrasound. Of these 401 patients, 82 had a 3.3F sheath, 298 had a 4F sheath, and 21 had a 5F sheath. The prevalence of pulse loss in patients with 3.3F sheaths was 8.5%, compared to 16.8% in patients with 4F sheaths, and 14.2% with 5F sheaths. Fisher's exact test showed no statistically significant difference among the groups for incidence of pulse loss (p value 0.170) or heparin treatment (p value 0.379). However, when multiple logistic regression were performed, sheath size was significantly associated with pulse loss; odds ratio for pulse loss was 2.92 (95% CI 1.23-6.95) for 4 Fr catheters compared to 3.3 Fr catheters (p value = 0.015). A similar trend was found for treatment with heparin; odds ratio for administration was 2.46 (95% CI 0.69-8.69) for 4 Fr catheters compared to 3.3 Fr catheters, however, this did not meet our threshold for significance (p value 0.164). Conclusions: Pulse loss following cardiac catheterization in children is a relatively common complication, especially in babies with small femoral arteries. Historically 4F sheaths were the smallest sheaths available, however, during the last decade, smaller sheaths have been developed. This retrospective study showed that in this high-risk patient population of small infants, a smaller 3.3 Fr sheath (Super Sheath, PediaVascular) is less likely to cause pulse loss than a standard 4F sheath. Since the conclusion of this study, our institution has routinely used the Prelude Ideal sheath from Merit Medical which accepts 4F catheters but has the outer diameter of a typical 3F sheath. The hope is this even smaller sheath will further decrease the prevalence of pulse loss in this vulnerable population. Hybrid Placement and Subsequent Hybrid Successful Repositioning of Unbuttoned Amplatzer Septal Occluder Through Anterior Mini-Thoracotomy in a Premature Infant Rupesh Kumar Natarajan, Varun Aggarwal, John Bass, James Berry, Massimo Griselli, Gurumurthy Hiremath University of Minnesota, Minneapolis, USA Abstract A 4-month-old female, former 24 weeks, weighing 4.0 kg, with moderate secundum atrial septal defect (ASD) in the setting of severe respiratory disease of prematurity and pulmonary hypertension (on inhaled nitric oxide and sildenafil). Baseline hemodynamics were significant for moderately elevated pulmonary artery pressures (mPAp 27 mmHg) and normal PVR 2.3 iWU improved with vasoreactivity testing. Due to a small patient size and a tortuous thin IVC, a decision was made to close the ASD per-atrially through a hybrid anterior mini-thoracotomy approach. A regular mini TEE probe could not be passed and a 'micro TEE' probe was used which limited the ability to get good images. By TEE, the defect measured 0.6-0.7 cm with adequate rims all around except the retro-aortic rim (2 mm). Surgical right anterior mini-thoracotomy through a 5th intercostal space was performed and purse string suture was placed in the right atrium. An 18 gauge needle and a 0.035 00 Emerald J tip wire was advanced through the purse string across the ASD and positioned tip in the left lower pulmonary vein using echo guidance. A 6 Fr short sheath, hand shaped to provide torque capability, was advanced over the wire and tip positioned in the left atrium. An 8-mm Amplatzer Septal Occluder (ASO) (St Jude Medical Inc.), prepped in usual fashion, was deployed under TEE guidance with no residual atrial level shunting although the images were suboptimal with the micro TEE probe. At follow-up, the occluder was appeared to have missed catching the superior and posterior rim, 2 days later it was malpositioned and had unbuttoned with the right atrial disc partly in the left atrium. The child was taken back to the cath lab, under TEE guidance, an 8 fr sheath was introduced through the same anterior mini-thoracotomy incision and through the right atrial purse string suture. A 10-mm Amplatz Gooseneck Snare (eV3 Endovascular, Inc.) was positioned over the microscrew and snared. The right atrial disc was partially recaptured, and device redeployed across the atrial septum. Epicardial echocardiography was used in conjunction with TEE which confirmed good capture of all rims. Child was extubated after 6 days and was weaned off CPAP 12 days later. At 3 weeks of follow-up, the device was well seated with small residual shunt through the waist and was discharged home. Dislocation of ASO placed by hybrid approach through minithoracotomy has been previously described in two adult studies. Occluder dislodged into the right atrium in all five cases and underwent immediate surgical repair with cardiopulmonary bypass (CPB). In our case, detection of malposition was early when the occluder was still partially attached to the septum. This enabled us to attempt hybrid snare retrieval through mini-thoracotomy which is a novel and feasible approach for malpositioned ASO devices that has not been previously reported. It could be considered as a good alternative to transcatheter percutaneous or surgical retrieval techniques whenever possible given limited exposure to fluoroscopy and avoiding CPB. Jay Relan, Saurabh K. Gupta, Rengarajan Rajagopal, Sivasubramanian Ramakrishnan, Gurpreet S. Gulati, Sanjiv Sharma, Shyam S. Kothari, Anita Saxena, Vinay K. Bahl All India Institute of Medical Sciences, Delhi, India Abstract Aims: Superior sinus venosus defect is the most common extraseptal interatrial communication. The morphology of superior caval veinright atrium junction and pulmonary veins is variable and determines the modality and the technique of repair. In this study, we sought to clarify the morphoanatomy of sinus venosus interatrial communication using computed tomography. Methods and Results: A total of 100 computed tomographic angiograms of patients with superior sinus venosus defect were systematically analyzed using a pre-defined proforma. The mean age was 31.4 ± 16.9 years (Range-0.33-66 years). The mean transverse and supero-inferior diameters of the sinus venosus defect were 18.4 ± 5.7 mm and 17.0 ± 5.3 mm, respectively. In sixty-nine (69%) patients, superior caval vein was overriding the atrial septum, with more than 50% override in five patients. All patients had anomalous drainage of right superior pulmonary vein. Additionally, right middle and inferior pulmonary vein drained anomalously in 95 and 18 patients, respectively. Thirty-six patients had at least one pulmonary vein from the upper lobe of the right lung connecting to superior caval vein more than 2 cm cranial to the superior caval veinright atrium junction. Six patients had discrepant drainage of the lung segments of the same lobe with some segments draining to the right atrium while other segments draining normally to the left atrium. Twenty-one patients had an associated persistent left superior caval vein. Conclusion: Morphology of superior caval vein-right atrium junction and connection of anomalously draining pulmonary veins in superior sinus venosus defects were quite variable. The anomalous drainage of pulmonary veins is not limited to right upper lobe. In a large number of patients, middle lobe drains anomalously while a minority also have anomalous drainage of lower lobe. Detailed morphological assessment by computed tomography can help in surgical planning as well as selecting patients suitable for interventional closure. Background: Annualized endocarditis rates as high as 2.3% have been reported following Melody valve transcatheter pulmonary valve replacement (TCPVR). It has been suggested that ''pre-stenting'' with a PTFE-covered stent can lower the rate of endocarditis. Methods: The experiences at Mattel-UCLA and Rady-UCSD were reviewed for incidence of endocarditis in transcatheter valves. Melody valves implanted with or without a PTFE-covered pre-stent were compared, as well as Melody vs. Sapien valves, which come with a PTFE covering. Kaplan-Meier curves were generated to compare freedom from endocarditis between these different valves and implantation procedures. Results: Since 2010, there were 399 Melody valve and 124 Sapien valve TCPVRs performed between UCLA and UCSD. Of the Melody valve implants, there were 27 performed after placement of a PTFEcovered CP stent. There were no cases of endocarditis with Melody valve implants after use of covered pre-stents and only one case of Sapien valve endocarditis. The Kaplan-Meier curves shown below demonstrate the divergence of endocarditis incidence in valves covered by PTFE or implanted within PTFE stents. In a large dual-center experience, neither Melody valves implanted within PTFE stents nor PTFE-covered Sapien valves showed significant incidence of endocarditis. These patients will continue to be followed to determine if this effect is significant with time. model and the effects of radial force on growing tissue was investigated. Methods: Self-expandable nitinol stents with 4 different radial forces were designed and manufactured. Prototype stents were implanted in the abdominal aorta or iliac artery of four 50 kg, 3-month-old pigs for a duration of 90 or 180 days. Average final weight of animals after 180 days was 139 kg. Prior to explant, stents were assessed by angiography and then by micro-CT and histopathology after explantation. Results: Two stents were explanted after 90 days and the remainder at 180 days. None of the pigs had major complications nor were there issues with deployment, dissection, aneurysm formation, or fracture. Figure A1 and A2 shows the angiography of the native aorta before and 180 days after stenting. Figure B shows a graph of vessel growth; the native vessel grew in the range of 1.4 mm to 3.1 mm/6 months while the stented vessels always grew at higher rates ranging from 1.7 mm to 6.6 mm/6 months. There was a 22-27% growth in diameter for stented vessels versus 13% for native vessels. Histological findings ( Figure C) were comparable among all stents with overall mild injury score, and with all stents showing mature neointima and focal mild inflammation without extension to the underlying arterial wall. Higher radial force stents caused asymmetric deformation of arteries with increased, but localized inflammation. Conclusion: Self-expanding stents implanted in the aorta are able to expand in the aorta without inhibiting growth or causing vascular injury. This strategy could have promise in the treatment of neonatal coarctations and pulmonary artery stenoses. Our Experience of Device Closure of Ostium Secundum Atrial Septal Defect (OS ASD) Under Transthoracic Echocardiography (TTE) and Fluoroscopy Guidance Without Using of Transesophageal Echocardiography (TEE) Dr. M. Kalyanasundaram, Pediatric Cardiologist, GKNM Hospital, Coimbatore, India Abstract We report successful device closure of OS ASD in 58 patients (male 23, Female 35) with age ranged from 8 months to 75 years (median age 4 years) and weight ranged from 5.5 to 84 kg (median weight 14.6 kg) done between 15.10.19 and 20.3.20 with success rate of 95% and no major complications. Introduction: Most of the centers use TEE and fluoroscopy and some centers use only TEE and TTE without fluoroscopy guidance to deploy the ASD device. We observed some patients complaining of pain and irritation in the throat and some had cough with blood-tinged sputum after ASD device closure was done with TEE guidance. We thought these complains were probably due to injury to the throat and esophagus by the TEE probe manipulation. Sometimes we encountered the problem of fully opened LA disc failure to align with the atrial septum while it was deployed under TEE guidance. In some of these cases, the device got aligned well with the septum once TEE probe was pulled up above the left atrium (LA) level. We hypothesized that compression of LA by the TEE probe was the reason for failure of the device to align with septum Methods and Materials: 61 patients (male 24, Female 37) with age ranged from 8 months to 75 years (median age 4 years) and weight ranged from 5.5 to 84 kg (median weight 14.6 kg) were included in our study. All patients received loading doses of antiplatelets one day prior to the procedure. Procedure was done under general anesthesia with endotracheal intubation in 41 patients and under IV sedation in 20 patients. We used GE N95 echocardiography machine and fluoroscopy in all our patients to deploy the device. Discussion: Out of 61 patients, device was deployed in 58 patients using TTE with success rate of 95%. We switched over to TEE in 3 patients, since septal margins were not clear in 2 patients before the procedure and in 1 patient after the deployment of device. Device closure of ASD only with TTE guidance was attempted to circumvent the post-procedure throat pain and irritation and also to avoid haemoptysis due to TEE probe injury. None of our 58 patients had these symptoms though it was difficult to get the throat pain history from small children. In our previous experience with TEE-guided deployment we encountered in some patients the problem of aligning the device with septum in spite of LA disc was fully opened. But the device aligned well with septum once the probe was pulled up above the LA level. This we attributed to the LA compression by the TEE probe preventing the fully expanded LA disc to align with the septum. None our patients in this study had such a deployment problem Conclusion: Device closure of ASD under the guidance of TTE and fluoroscopy but without TEE is feasible, safe, and easy to align the device with septum in view of absence of compression of LA by TEE probe. Objective: Pulmonary valve replacement (PVR) has become a common procedure in congenital heart disease patients and can be accomplished via surgical, transcatheter, or hybrid approaches. There are significant inherent advantages, especially from the patient perspective, to transcatheter PVR. However, transcatheter valves are only applicable in patients with a suitable landing zone. Further, there are inherent advantages to avoiding unnecessary use of cardiopulmonary bypass (CPB) in patients who require surgical cardiovascular interventions. Since 2017, we have adopted a standardized approach to PVR that includes all approaches to PVR. This includes off-pump hybrid PVR being preferred to standard on-bypass surgical PVR when the RVOT is too large for available transcatheter valves. The objective of this work is to review the results of our standardized institutional approach to PVR. Methods: A retrospective review of all PVR cases and patient followup between February 2017 and February 2020. Patients underwent clinically indicated pre-and intraprocedure testing including cardiac MRI, transcatheter right ventricular outflow tract (RVOT) balloon sizing and coronary compression (CC) testing. Hybrid PVR entailed off-pump RVOT plication with subsequent percutaneous transcatheter PVR during the same procedure. We present our results of this systematic approach, aimed at minimizing the use of CPB. Results: PVR was indicated in 55 pts. Primary transcatheter PVR was attempted in 37, a hybrid procedure was performed in 11, and onpump surgical PVR was performed in 9. Median age at PVR was 27 years (6-65 years) and the most common diagnosis was tetralogy of Fallot (n = 39). Primary transcatheter PVR was successful in 35/37, with 2 converted to surgical PVR for stent/valve migration. Surgical valve implantation on cardiopulmonary bypass was utilized for positive CC testing (n = 4), stent/valve system migration (n = 2), or patient preference over the newer hybrid approach (n = 3). The hybrid group had a mean RVOT diameter of 34 mm (32-38 mm) by balloon-sizing pre-RVOT plication and then 25 mm (22-27 mm) post plication. All hybrid procedures were performed without CPB, except for one patient who underwent surgically-guided delivery of the transcatheter PVR due to change in RVOT anatomy/orientation pre and post plication. Median length of stay following procedure was 1 day for transcatheter PVR, 5 days for surgical, and 3 days for hybrid (p = 0.02). Median follow-up period was 1.5 years and there have been no reported episodes of endocarditis. There have been 3-valve reinterventions to date including one balloon valve dilation in the transcatheter PVR cohort, one balloon valve dilation, and a subsequent transcatheter valve-in-valve PVR in the surgical cohort. One hybrid patient expired (11 months post-index procedure) for multiple reasons, but including a coronary artery insult possibly occurring at the time of RVOT plication. Conclusion: A systematic approach to PVR utilizing all approaches in pre-defined order of preference leads to consistent outcomes in a wide variety of anatomic configurations. Transcatheter PVR may be accomplished in the majority of patients with RVOT dysfunction. In patients with an unsuitably large outflow, utilizing a hybrid off-pump RVOT plication with subsequent transcatheter PVR is effective and avoids the need for cardiopulmonary bypass. Animal Testing of an HDBraid PDA Device for Low Birth Weight Infants Daniel Levi UCLA, Los Angeles, USA Abstract Background: Use of a microbraiding technology has been used to produce the WEB, a neurovascular aneurysm treatment recently approved by FDA. Novel, patented HDBraid technology has been used to produce the LOBO (Okami Medical, Aliso Viejo), an FDAcleared peripheral occlusion device. HDBraid technology has also been used to produce a device design specifically for closure of PDAs in preterm infants using a microcatheter for device delivery. Methods: Two-disk PDA devices were manufactured from 144 wires using the previously described and proprietary braiding technology and traditional shape setting. The device has two discs (4 mm and 7 mm) designed to elongate in a tubular fetal-type PDA ( Figure 1 ). The PDA device is compatible with most commercially available 0.027 00 microcatheters. The ductus of three newborn piglets was recannulized using balloon angioplasty with a 5 or 6 mm Tyshak Mini balloon (NuMed, Hopkinton, NY) in order to create 3 mm PDAs. The PDAs were occluded in both antegrade and retrograde fashion with the PDA device using ECHO and fluoroscopic guidance ( Figure 2 ). Angiograms and ECHOs were performed to document occlusion and devices were examined postmortem as well. The ability to deliver, visualize, and release the device was assessed as well as time to complete angiographic occlusion. Results: PDAs were crossed and successfully balloon open in three piglets weighing 1.9, 2.4, and 2.8 kg. After angioplasty, the PDA dimensions ranged from a diameter of 2.8-4.5 mm with lengths ranging from 5.7-7.4 mm. All devices were delivered and released without difficulty. The proximal and distal markers on the devices were easily visualized by fluoroscopy and the device was also able to be imaged by ECHO. Two PDAs were occluded antegrade and one retrograde. In one animal, the device was recaptured prior to release and redeployed. All PDAs were completely occluded within 5 min of device delivery without obstruction to the left pulmonary artery or descending aorta. In two of three animals, occlusion was immediate. Figure 2 demonstrates the angiographic and ultrasound appearance of the PDAs before and after occlusion. On postmortem exam, all three devices were in excellent position with an obvious layer of fibrin covering the surface of the braided nitinol ( Figure 3 ). Conclusion: Initial animal testing of the new microcatheter-based PDA device justifies further investigation of this device as a possible new device for occlusion of tubular PDAs in low birth weight infants. Use of the Penumbra Embolization System for Vascular Occlusion in Patients with Congenital Heart Disease: A Single-Center Experience Emily C. Kish, Renelle S. George, John S. Lozier, Martin L Bocks Rainbow Babies & Children's Hospital, Cleveland, USA Abstract Background: Occlusion of vascular anomalies is often necessary in patients with congenital heart disease (CHD). These anomalies can cause a variety of symptoms, including hypoxemia from right-to-left shunting, pulmonary overcirculation, angina from coronary insufficiency, and hemoptysis. These vessels are often tortuous, have acute take-offs and can be difficult to occlude using larger occlusion devices. The Penumbra Embolization System (PES) offers several advantages over other devices, including the ability to occlude tortuous or difficult to access vessels, resheath and repack coils, lowprofile delivery catheters, and reduced need for numerous coils for particularly voluminous or long collaterals. We report our experience using PES for vascular occlusion in patients with CHD. Methods: We retrospectively reviewed cases in which Penumbra coils were used for transcatheter vascular embolization at our institution between July 2018 and March 2020. Demographics, diagnoses, and catheterization data were analyzed. Results: Eleven patients underwent occlusion of 17 vessels in 12 procedures during the study period. The median age was 10.5 years (0.9-58.0 years) with a median weight of 33.5 kg (8.1-98.0 kg). Seven patients had single ventricle physiology. There were six aortopulmonary collaterals, seven venovenous collaterals, two coronary artery fistulas (CAF), and two bronchial artery collaterals. Of the 12 cases during the study period, vascular occlusion was the only intervention performed in eight. PES products were the only devices used in 16/17 embolized vessels. The most common device combination involved anchoring Ruby coils or PODs followed by packing coils in 10 vessels. A Ruby coil or POD alone was sufficient for embolization in four vessels. Two vessels were embolized using packing coils only. In one vessel, a packing coil was used following placement of an Amplatzer TM Vascular Plug 4. The size of the Ruby or POD anchor coil ranged from 2 mm by 1 cm to 6 mm by 50 cm. The packing coils ranged from 5 cm to 60 cm in length. Two coils or fewer were used to achieve desired results in 13 vessels (76%). All coils were successfully delivered through the Lantern microcatheter. Post-release angiograms demonstrated complete occlusion in 15 vessels, with near complete occlusion in two. There were no procedural complications. Follow-up angiography was not performed in any patients except for the patient with CAF, which was recanalized at six-month follow-up. The patient returned to the cath laboratory for successful occlusion using an additional POD followed by a packing coil. Conclusion: We report the successful embolization of multiple vascular anomalies using various products from the PES. Complete embolization was achieved in the majority of cases, with no associated adverse events. The patient with recanalized CAF had nondensely packed coils. We now densely opacify and repack the Penumbra coils to avoid this outcome. Long-term follow-up may be needed to evaluate vessel patency and assess for recanalization. The PES effectively occludes large and high-flow vessels without the need to pack a large number of coils or use of a large device/delivery system. The microcatheter delivery system enables occlusion of difficult to access or tortuous vessels. My Nightmare Case in Cath Lab; Fit The Slip Amjad Mahmood 1 , Khurram Akhtar 2 1 AFIC@NIHD, Rawalpindi, Pakistan. 2 AFIC&NIHD, Rawalpindi, Pakistan Abstract A 12*40 mm balloon-mounted peripheral stent was deployed at RVOT to rescue severely stenosed infundibulum in a lady of 18 years with TOF who had failing RV extreme desaturation and declared unfit for surgical correction. During final deployment, the stent embolized into LPA. The fully expanded stent was successfully dragged and redeployed with the help of balloon inflation within the stent. After successful redeployment of the same stent, RVOT was adequately expanded and the patient saturated well to avoid further hypercyanotic spells. Background: Patients with native or patched right ventricular outflow tracts (RVOTs) and severe pulmonary regurgitation (PR) comprise a large portion of the congenital heart disease population, for which there are no currently approved transcatheter treatments available. The Harmony Early Feasibility Study is the first FDAapproved study evaluating transcatheter pulmonary valve implantation in this population. Methods: This non-randomized, prospective study evaluated the Harmony Transcatheter Pulmonary Valve (HTPV) device in the native RVOT. Candidates underwent detailed anatomic eligibility screening and were enrolled across three sites in the U.S. and Canada. The primary objective was to obtain in vivo data to confirm assumptions on loading conditions for future in vitro frame evaluations. Procedural feasibility, safety, and HTPV performance were assessed, and planned clinical and echocardiographic follow-up extends to 5 years. Results: From 66 patients enrolled in the feasibility study, 21 were catheterized, and 20 underwent HTPV implantation. As previously published, 17 patients completed 3-year follow-up, with no late stent fractures or valve migration, and no reports of thrombosis, or endocarditis through 3 years. CT evaluation in sixteen patients showed anatomic incorporation of the valve, and tissue ingrowth that did not affect hemodynamic performance with the mean right ventricular outflow tract gradient remaining stable at 15.7 ± 5.5 mmHg. At 3-year follow-up, one patient (6.3%) had mild PR with the remaining patients having none/trace regurgitation (vs. 95% with severe PR at baseline). One patient (6.3%) had mild paravalvular leak (PVL) at 3 years while the remaining patients had none/trace PVL. At the time of presentation, 5-year results will be available. Conclusions: Longer-term follow-up data for TPV implantation in the native outflow tract were limited, and the 5-year outcomes from the Harmony Early Feasibility Study represent the longest follow-up of any TPV in the native outflow tract. . There were no demographic differences between eras. There were no differences in mortality, treatment failures, complications, or reinterventions between eras. Post-procedure length of stay was shorter in Era 2 (8 vs 22 days, p \ 0.05). There were less surgical revisions for PDA stent patients (2% vs 20%, p \ 0.05). Post-procedure recovery surrogate endpoints favored Era 2 and PDA stenting. Additional analysis revealed PDA stent (compared to BTS) patients had shorter overall (18 vs 43 days, p \ 0.05) and post-procedure (11 vs 29 days, p \ 0.05) length of stay and more symmetric branch pulmonary arteries (0.9 vs 0.7, p \ 0.05) at subsequent surgery. Conclusions: Universal PDA stenting for all ductal-dependent cyanotic newborns is safe and effective, and may have lower morbidity and require fewer resources than selective PDA stenting. Neonatal PDA Stenting for Ductal-Dependent Pulmonary Blood Flow Considerations: Anticoagulation Therapy, Unplanned Reintervention Rates, and Pulmonary Artery Growth Yousef Arar, V. Vivian Dimas, Surendranath R. Veeram Reddy, Thomas M. Zellers, Carrie Herbert University of Texas Southwestern/Children's Medical Center, Dallas, USA Abstract Background: Patent ductus arteriosus (PDA) stenting represents a viable alternative to surgical shunts (modified Blalock-Taussig shunt; MBTS) for treatment of neonates with critical congenital heart disease in need of stable postnatal pulmonary circulation without the need for cardiopulmonary bypass or sternotomy. Our institution's anticoagulation protocols post-PDA stenting consist of either aspirin Pediatr Cardiol (ASA) alone or ASA with enoxaparin. Our primary aim was to evaluate our anticoagulation protocols to help clarify which were most helpful in preventing unplanned reinterventions and promote pulmonary artery (PA) growth, especially as it relates to the growth of small jailed PAs. Methods: Retrospective chart review was performed on neonates who underwent PDA stenting for ductal-dependent pulmonary blood flow at our institution between 2014 to 2020. We specifically compared anticoagulation therapy as it relates to reintervention rates and PA growth for jailed versus non-jailed PAs. Bare-metal coronary, nondrug-eluting stents were used for all patients. Anticoagulation therapy was based on interventionalist preference with no institutional consensus on practice. Results: A total of 76 patients underwent successful PDA stenting with demographic and outcome variables outlined in Table 1 . There were no procedure-related deaths. Figure 1 summarizes total rate of unplanned reinterventions and PA growth analysis. A total of 34 patients were excluded from the study for the following: lack of presurgical PA imaging (n = 12), death (n = 9), current status of PDA stent (n = 6), status post heart transplant (n = 5), or transfer of care (n = 2) for a total of 42 patients. A comparison of anticoagulation therapy for jailed versus non-jailed PAs was analyzed for rates of unplanned reinterventions and PA growth (Table 2) . Anticoagulation strategy using antiplatelet therapy (ASA) alone versus antiplatelet plus anticoagulation therapy (ASA plus enoxaparin) did not significantly change the rate of reintervention for jailed versus non-jailed PAs. In addition, there was no statistically significant benefit in PA growth for jailed PAs when using ASA plus enoxaparin versus ASA alone (Table 3) . Patients who received ASA plus enoxaparin for documented thrombus post-procedure had the highest rate of PDA stent reintervention. A case example of each group is summarized in Figure 2 . No bleeding or acute thrombotic events were noted in this patient cohort after procedural success. Conclusions: Neonatal PDA stenting is a safe and feasible alternative to MBTS for ductal-dependent pulmonary blood flow. Anticoagulation strategies using ASA therapy alone were adequate with no appreciable benefit from adding enoxaparin as it relates to rate of unplanned reintervention or PA growth for jailed/non-jailed PAs. Future studies are needed to assess rates of ASA resistance in the neonatal PDA stenting for ductal-dependent pulmonary blood flow cohort. Medtronic, Mounds View, MN, USA. 9 Nationwide Children's Hospital, Columbus, OH, USA Abstract Background: The self-expanding Harmony transcatheter pulmonary valve (TPV) is designed to relieve chronic pulmonary regurgitation (PR) in the native or large patched right ventricular outflow tract (RVOT). Safety and efficacy of the Harmony TPV were reported previously as part of the Harmony Early Feasibility Study. The Harmony TPV Pivotal Trial continues this investigation and includes two valve sizes-TPV22 and the larger TPV25-as well as a small subset of modified TPV 25 Harmony implants, which included a redesigned frame to improve performance. Methods: The Harmony Pivotal Trial is a prospective, single-arm study evaluating Harmony device performance and procedural safety in patients indicated for surgical pulmonary valve or conduit placement. Patients were enrolled at 12 participating centers in the U.S., Japan, and Canada. Candidates included patients with severe PR on echocardiography or PR fraction C 30% by magnetic resonance imaging. The primary safety endpoint was freedom from procedureor device-related mortality at 30 days, and the primary efficacy endpoint was acceptable hemodynamic performance (mean RVOT gradient B 40 mmHg on echocardiography and PR fraction \ 20% on magnetic resonance imaging or PR \ moderate by echo) and no interventions on the Harmony TPV post implant through 6 months. Results: Forty patients underwent TPVR with either the TPV22 (n = 21) or TPV25 (n = 19), followed by 10 additional patients receiving a modified TPV25, for a total of 50 study patients. The mean age was 28.7 ± 11.3 years. Thirty-one patients (62%) were male, 46 (92%) had an original diagnosis of tetralogy of Fallot, and the median number of prior open-heart surgeries was 1 (Q1, Q3: 1, 2). Primary safety and performance outcomes were previously reported for the TPV22 and TPV25 cohort, along with 30-day performance of the modified TPV25. The current presentation will include complete data for 6-month endpoints in all patients, including those who received the modified TPV 25. Conclusions: The growing body of data on the Harmony TPV show its early promise as a less-invasive alternative to surgical pulmonary valve replacement in selected patients with severe PR in a native or patched RVOT. The full 6-month results represent the longest followup to date using the modified TPV25 valve design. Jenny Zablah 1,2 , Salvador Rodriguez 1 , Ryan Leahy 1 , Gareth Morgan 1,2 1 Children's Hospital Colorado, Aurora, USA. 2 University of Colorado Hospital, Aurora, USA Abstract Objective: To evaluate the impact of multimodality imaging technology application during percutaneous pulmonary valve implantation (PPVI) for radiation reduction without increasing the rate of adverse events. Introduction: Among all the percutaneous procedures, PPVI could potentially have one of the highest radiation exposures for patients. Different protocol modifications have been implemented to address this problem (i.e., improvements in guidance system, delivery system, valve design, post-implantation evaluation) and the effectiveness of individual modifications have been proven, however, the effect of a combined approach has not been reported. Methods: We performed a retrospective chart review of 76 patients who underwent PPVI between January 2018 and December 2019. Patients were classified in traditional protocol, using routine angiography and/or 3D rotational angiography (3DRA); and multimodality protocol, according to the application of new technology (such as VesselNavigator for guidance, Long DrySeal Sheath for valve delivery, and Intracardiac Echocardiography for valve evaluation after implantation). Radiation metrics, procedural time, and clinical outcomes were compared between groups. Results: When the traditional protocol group was compared with the multimodality protocol group, a significant reduction was described for total fluoroscopy time (31.6 min vs. 26.2 min), dose of contrast per kilogram (1.8 mL/Kg vs. 0.9 mL/Kg), DAP/kg (26.6 lGyÁm 2 /kg vs. 19.9 lGyÁm 2 /kg), and Air Kerma (194 mGy vs. 99.9 mGy). Interestingly, a reduction for procedure time was noted (140 min vs. 116.5 min), but no statistical difference was described. No differences were found for clinical outcomes or the presence of complications between groups. Conclusions: The combination of novel technology in PPVI caused a significant reduction in radiation metrics without increasing the complication rate in our population. Children's Hospital Colorado, Aurora, USA. 2 University of Colorado Hospital, Aurora, USA Abstract Objective: To evaluate the ability of balloon coronary compression testing during percutaneous pulmonary valve implantation (PPVI) to predict the final spatial relationship between the implanted valve and the coronary arteries, and to explore how variations in RVOT substrates, equipment, and technique can influence this. Background: Despite the widespread use of the ''balloon coronary test'' as the preferable method to rule out the risk of coronary compression (CC), this event has been described after PPVI where coronary balloon test suggested no risk or low risk, calling into question the accuracy of this assessment. No methods to evaluate the false-positive rate have been established, however, some possible factors that affect the assessment have been proposed. Methods: We performed a retrospective chart review of 84 patients who underwent PPVI between January 2018 and December 2019 and selected 35 patients whose archived imaging was suitable to perform analysis of the ''balloon coronary test.'' We focused on the spatial disparity between the RVOT position with the testing balloon inflated and the eventual implanted valve position to classify the test as inaccurate or accurate. Baseline and procedural characteristics were evaluated to determine their association as predictors of test accuracy. Results: 36.1% of cases were classified as having an inaccurate coronary balloon test. Among the baseline characteristics, the RVOT substrate was found as a significant predictor for an inaccurate test. Related to this characteristic, the balloon used and the smaller sizes of the implanted valves were found associated with the test inaccuracy. The rest of the baseline an procedural characteristics did not show association with the event of interest. Conclusions: Based on our findings balloon coronary testing is not an accurate method of predicting the RVOT position after valve implantation. This may translate to a high rate of false positives for coronary compression in the wider PPVI population. Subhrajit Lahiri, Athar Qureshi, Henri Justino, Emad Mossad Baylor College of Medicine, Houston, USA Abstract Background: Pediatric cardiac interventions via percutaneous common carotid artery access have been shown to be safe and effective. However, the impact of placement of a sheath in the carotid artery for interventions on changes in cerebral perfusion is unknown. In this study we use cerebral near-infrared spectroscopy (cNIRS), which has been established as a marker of cerebral perfusion, to analyze the effects of carotid artery access for cardiac interventions on cerebral perfusion. Methods: This is a retrospective chart review done at a tertiary care center for all pediatric patients that underwent percutaneous cardiac catheterization via carotid artery access from January 2009 to January 2020. All patients who had ipsilateral cNIRS monitored on the side of carotid artery access were included. Patients with no ipsilateral cNIRS data or partial cNIRS data were excluded. Primary outcome was the change in cNIRS with carotid artery access. Mean cNIRS for 15 min before obtaining access was compared to mean cNIRS during the procedure and 15 min after removal of the carotid artery sheath. We hypothesized that there is significant drop in cNIRS on the side of carotid artery access. Results: There were 48 catheterizations in the study period where carotid artery was accessed. Out of those, 22 catheterizations with complete data were included in the study. Thirteen (50%) were males. Median age was 23 (IQR 7,79) days. The indications for carotid artery access were PDA stent implantation (n = 13,48%), aortic valvuloplasty (n = 5,22%), balloon angioplasty of coarctation of aorta (n = 2,10%), and renal artery angioplasty (n = 1,4%). In 16 patients (72%), the left common carotid artery was accessed. The median weight of the patients was 3.3 kg (IQR 2.8, 2.9). The most common sheath size used was 4F in 16 patients (72%). The average cNIRS prior to the procedure was 67 ± 15 (mean ± SD), during the procedure was 68 ± 20 (mean ± SD), and after removal of sheath was 68 ± 21 (mean ± SD). Paired t test of cerebral cNIRS before and during the procedure showed no significant change with carotid artery access (p = 0.08). Paired t test of means of cNIRS during and after procedure showed no significant change with removal of carotid artery sheath. No patient in the series had a documented neurologic deficit following the procedure. Conclusion: Percutaneous common carotid artery access is not associated with a decrease in cNIRS on the side of the access suggesting there is no significant change in cerebral perfusion with carotid artery access. conduits, and follow-up to 7 years demonstrated durable clinical and hemodynamic outcomes. Final ten-year data from the Melody IDE trial were first presented in spring 2020. Methods: One hundred and seventy-one patients with RVOT conduit obstruction and/or regurgitation were enrolled in the trial. Patients were followed out to ten years. Valve dysfunction was assessed as freedom from reoperation, catheter reintervention, or hemodynamic dysfunction (defined as moderate or severe pulmonary regurgitation and/or mean RVOT gradient [ 40 mmHg). Long-term safety outcomes included device-related serious adverse events, stent fracture, catheter reintervention, surgical conduit replacement, and death. Results: Among the 171 enrolled patients, a total of 150 patients underwent transcatheter valve implantation (TPVI) with the Melody valve. Median age at TPVI was 19 years (range 7-53). Fifty-one percent of enrolled patients had tetralogy of Fallot. As previously published, mean RVOT Doppler gradient was 17 mmHg at discharge. Five-year freedom from reintervention and freedom from explant were 76 ± 4% and 92 ± 3%, respectively. Thirty-two patients underwent RVOT reintervention at a median 4.5 years of follow-up. The majority of reinterventions were for RVOT obstruction (n = 27), while two patients underwent reintervention for endocarditis, and one patient for RV dysfunction. The current encore presentation will review 10-year outcomes as previously presented at SCAI 2020. Conclusions: Since it was first introduced, the Melody TPV has been an adaptive tool for less-invasive conduit reintervention and a lifechanging innovation for congenital heart disease (CHD) patients who face multiple reoperations through adolescence and beyond. Ten-year outcomes from the Melody IDE trial demonstrate long-term efficacy and durability of TPVI in dysfunctional RVOT conduits. These clinical trial results provide a strong foundation for future technologies in transcatheter therapies and evidence-based medicine for the CHD patient population. John Lozier, Emily Kish, Renelle George, Martin Bocks UH Rainbow Babies & Children's Hospital, Cleveland, USA Abstract Optimal angiographic imaging angles are essential in transcatheter interventions. However, achieving ideal views of complex or unique cardiovascular structures can be challenging. We sought to develop a tool to assist in obtaining optimal imaging angles using the mathematics of vectors. For a given vector v 1 , there exists a plane defined as the set of all vectors that are perpendicular to v 1 . This concept may be useful in cardiac angiography: if the ''down-the-barrel'' viewing angle of a vessel or structure is known, then many orthogonal camera angles could be derived to provide optimal ''profile'' views. Further, if two profile viewing angles of a structure are known, then the down-thebarrel angle can be derived. Methods: Two mathematical formulas were developed to solve for orthogonal angles to a known camera position in a standard fluoroscopy system. In formula 1, a user entered the cranial/caudal and LAO/RAO angles of the down-the-barrel view, and one user-defined angle for a profile view (cranial/caudal or LAO/RAO); the formula then solved the second profile angle, with the result that the profile view was orthogonal to the down-the-barrel view. Formula 2 derived the down-the-barrel camera angles when two profile views were known. The formulas were converted to a mobile computing app. To test the formulas, an X-ray phantom was designed and 3D printed. Results: The X-ray phantom's disc and cylinder were perpendicular by fluoroscopy. Moving either camera by single degree increments resulted in significant changes in the fluoroscopic appearance of the phantom. One hundred trials were performed to assess formula 1. Mathematically, formula 1 generated high-quality solutions, with a mean angle of 90.01 degrees (range 89.52 to 90.42 degrees) between the downthe-barrel view and the calculated profile angles. Fluoroscopically, 99 of the calculated profile angles appeared perpendicular, while one appeared to be one degree off perpendicular (mean fluoroscopic angle 0.01 ± 0.1 degrees off perpendicular). Ten trials were performed to assess formula 2, which also generated high-quality mathematical solutions. The mean angle between the known profile angles and the calculated down-the-barrel angles was 89.93 degrees (range 89.45 to 90.53 degrees). Fluoroscopically, nine of the calculated down-the-barrel angles appeared perpendicular, while one appeared to be one degree off perpendicular (mean fluoroscopic angle 0.1 ± 0.3 degrees off perpendicular). Discussion: We have successfully developed an easy-to-use tool to assist in obtaining optimal fluoroscopic images using the mathematics of vectors. Formula 1 can calculate a nearly unlimited number of orthogonal profile viewing angles when a down-the-barrel angle is known. Formula 2 derives the down-the-barrel angle when two profile views are known. This simple tool is likely to be useful in a number of interventional cases, including pulmonary artery rehabilitation, pulmonary vein stenosis, assessment of atrial septal occluders, and other complex interventions. The formulas could be made widely available via mobile computing app or integrated into cath lab fluoroscopy software. Ultimately this tool may optimize cardiac angiographic imaging and reduce unnecessary radiation and contrast exposure. Hydrodynamic test showed a pressure gradient oscillation between 5 and 20 mm, in basal or stress conditions, respectively. Experimental studies. Sheep were subjected to 3D echo-Doppler study, in 6th follow-up months, which showed satisfactory hemodynamic performance, with low transvalvular gradient (M = 6.60 mmHg). Ultrastructural Study: Six stents were explanted after 20 days to 21 months of follow-up to Ultrastructural analysis. All of which revealed no presence of calcium growth and prostheses structure was intact. Objective: Here, we present our mid-term results in Pediatric Cardiology Unit, Children Hospital, Mansoura University in of different approaches of percutaneous balloon aortic valve valvuloplasty (BAV) in cases of critical aortic stenosis (CAS) in the period from 2005 to 2018 to assess the safety and efficacy of transcatheter intervention for critical aortic stenosis. Method: Between April 2005 and June 2018, all consecutive patients with CAS treated with balloon valvuloplasty in our hospital were analyzed retrospectively. Patients were followed up from 18 months to 13 years (mean 100.8 months [8.4 years]) by clinical examination and echocardiography. RESULT: Sixty-seven consecutive patients were analyzed. Their gestational age was 37.53 ± 1.37 weeks. Eleven patients (16.4%) were preterm newborn. Postnatal age 8.5 ± 7.6 days, range 4-35 days. Weight 2.75 ± 0.43 kg. 58.5% was male and 41.5% was female. Fifty-seven of patient (85.07%) received PGE1 infusion before the procedure to maintain the ductal patency in a dose of 0.05 to 0.1 lg/kg/min. Balloon valvuloplasty was accomplished in 65 (97.01%) of 67 interventions. The procedural approaches, success, early outcome, complication rates, mid-term results, and aortic regurgitation were retrospectively studied. Pre-dilatation by Brio coronary balloon was used in 19 patients (28.35%) followed by TAYSHAk Ò mini balloon. TAYSHAk Ò mini balloon was used from the start in 48 patients (71.6%) with balloon annulus ratio 0.85. In nineteen patients, antegrade approach was used through the patent foramen ovale, in 21 patients, trans-femoral retrograde approach was used, whereas, in 25 patients, trans-carotid approach was used. Peak-to-peak pressure gradient across the valve fell from (85.4 ± 14.0) to (24.7 ± 14.0) (P \ 0.001). Left ventricular pressure fell from (101.4 ± 16.0) mmHg to (45.5 ± 10.5) mmHg (P \ 0.001). Two patients had very difficult aortic valve cannulation with the wire then referred for surgical valvotomy. Two patients lost follow-up. Echocardiography on follow-up revealed a mean trans-aortic systolic gradient of \ 30 mmHg, none to grade I aortic. On follow-up 6 children (9.2%) required a second balloon dilatation with good results. Conclusion: Balloon aortic valvuloplasty is relatively safe and effective in neonatal CAS. There is a different approach for this procedure. Antegrade procedure is safe and requires shorter procedure duration. It may be associated with a lower morbidity and mortality than surgical treatment Little is known about the effect of interventions that require repeated crossing of the TPV on valve leaflet integrity. This case series describes 6 patients who underwent pulmonary artery stent implantation and pulmonary balloon angioplasty through previously implanted Melody and Sapien (Edwards Lifesciences, Irvine CA) TPV. Methods: Six patients (3 females and 3 males), with mean age 15 years (range 10-20), mean weight 54 kg (range 39-66), 2 with tetralogy of Fallot (TOF), 3 with variant TOF (absent pulmonary valve, pulmonary atresia, pulmonary atresia/ventricular septal defect with major aortopulmonary collateral vessels), and one patient with truncus arteriosus type 1 underwent TPV implantation. Five patients underwent Melody valve implantation and one patient had a Sapien TPV implanted. All patients previously underwent surgical complete repair with development of severe pulmonary valve insufficiency and right ventricular enlargement necessitating TPV implantation. Following TPV implantation, 6 patients had evidence of either distal main pulmonary artery or branch pulmonary artery stenosis. Two of the patients, one requiring distal main pulmonary artery stenting and another requiring left pulmonary artery stent redilation, underwent a second procedure 10.2 and 7.4 months after TPV implantation, considered early in our experience. The other 4 patients underwent pulmonary artery intervention during the same catheterization procedure after first implanting the TPV. Both angioplasty balloons and stents were advanced over an Amplatz Super Stiff wire (Boston Scientific, Marlborough MA) or through a long transseptal sheath to minimize the number of times required to cross the TPV. All six patients underwent pulmonary artery angioplasty with Atlas Gold (Bard, New Providence, NJ), Vida (Bard), Powerflex (Cardinal Health, Dublin OH), or Opta Pro (Cardinal) balloons. Four of the six patients underwent stent implantation into distal main pulmonary artery stenosis (one patient) or right or left pulmonary artery (3 patients) with Palmaz Genesis (Cardinal) or Max LD (Medtronic) stents. All six patients underwent at least 2 interventions (median 2.5, range 2-4) through the TPV. All six patients underwent successful distal main pulmonary artery or branch pulmonary artery balloon angioplasty and/or stent implantation without complications. Postintervention angiography showed competence of the TPV with normal leaflet function and no evidence of pulmonary valve insufficiency, perivalvular leak, or valve migration. All patients had post-catheterization transthoracic echocardiography demonstrating TPV leaflet integrity without evidence of insufficiency. Postcatheter course was uneventful for all patients. Conclusion: In our series, multiple interventions through previously implanted TPV including balloon angioplasty and stenting of the distal main pulmonary artery and branch pulmonary arteries was safe, effective, and caused no damage to the previously implanted TPV. Roshan Valentine, Muthusubramanian Rajasekaran, Reddi Prasad Yadavalli, Rohan Augustine Manipal Hospital, Bangalore, India Abstract Thoracic central venous system comprises deep venous system continuing from the head, neck, upper limb to the heart through the thoracic inlet corresponding to the level of T1 vertebra. These include the superior vena cava (SVC), Brachiocephalic vein (BCV), subclavian vein (SCV), intrathoracic segment of Internal Jugular Vein (IJV), and suprahepatic Inferior Vena Cava (IVC). Stenoses of these vessels are not infrequent with most common cause being multiple punctures while cannulating the IJV or SCV. The other causes include turbulent flow secondary to AV shunts, thrombin sheath formation within the indwelling catheters. Clinically they present with ipsilateral arm or face swelling, increased venous pressure during hemodialysis(HD) and failed access. Rather than the conventional treatment options, endovascular management remains as a standalone promising treatment option. In this pictorial exhibit, we present 4 patients with central venous stenosis who were referred to Interventional Radiology department for endovascular management. Background: Interpatient variability in the size and morphology of right ventricular outflow tract (RVOT) can limit transcatheter pulmonary valve implantation (TPVI). A stent implanted into the RVOT can reduce RVOT size and provide a circular, stable landing zone for TPVI. This study evaluated the Alterra Adaptive Prestent with the SAPIEN 3 transcatheter heart valve (THV) in patients with dysfunctional RVOT/pulmonary valve (PV) in the US. Methods: This single-arm, prospective, multicenter study was designed to evaluate up to 60 patients with dysfunctional RVOT/PV, moderate or severe pulmonary regurgitation (PR), weight C 20 kg, and RVOT/PV proximal and distal landing zone diameter C 27 mm and B 38 mm, and minimum of 35 mm from contractile tissue to lowest pulmonary artery takeoff. The primary endpoint was THV dysfunction at 6 months, defined as RVOT/PV intervention, C moderate PR, and mean RVOT/PV gradient C 35 mmHg. Secondary endpoint outcomes included improvement in total PR at 30 days and acute device success, defined as a single Alterra Adaptive Prestent implanted in the desired location, a single THV implanted in the desired location within the Alterra Adaptive Prestent, RV-PA peak-to-peak gradient \ 35 mmHg post implantation, \ moderate PR by discharge, and free of explant at 24 h post implantation. Additional effectiveness outcomes included improvement in tricuspid regurgitation (TR) for patients with C mild TR at baseline. Freedom from adjudicated adverse events was determined with Kaplan-Meier estimates. Descriptive statistics were used for other endpoints. Results: Enrolled patients (N = 60) were a mean age of 29.5 years; 50% were B 21 years old. The cohort was 56.7% male with a mean weight of 73.1 kg, and 92% New York Heart Association class I/II. Fifty-nine patients had the Alterra and SAPIEN 3 THV devices concomitantly implanted; 1 patient had a staged procedure. All devices were implanted in the intended location. Acute device success was 93.3%: a single Alterra Adaptive Prestent implanted in the desired location (100%), a single THV implanted in the desired location within the Alterra Adaptive Prestent (96.7%), RV-PA peakto-peak gradient \ 35 mmHg post implantation (98.3%), \ moderate PR by discharge (98.3%), free of explant at 24 h post implantation (100%). At 30 days, \ moderate total PR was 98.3%; 1.7% (n = 1) had moderate PR ( Fig. 1) . At 30 days, TR was B mild in 83.4% of patients. No death, pulmonary embolism, RVOT reintervention, endocarditis, clinically relevant arrythmia, or coronary artery compression were reported at 30 days. Alterra frame fracture was 1.7% at 30 days and 10% at 6 months. Frame fracture was not associated with a change in valve function and no patient has required an intervention. The 6-month primary endpoint data will be available at the time of the presentation. Conclusion: Early results demonstrate the safety and effectiveness of the Alterra Adaptive Prestent and SAPIEN 3 THV in patients with dysfunctional RVOT/PV. A 7-month-old boy, Jehovah Witness, diagnosed with a 11-mm ventricular septal defect complicated with pulmonary hypertension was admitted to the ER with decompensated congestive heart failure, oxygen saturation of 92% at room air, bilateral crackles, and evident shortness of breath. The patient was stabilized with supplementary oxygen, diuretics, and inotropic support. Pulmonary infection was ruled out. Seven days after the admission, the patient was subject to a perventricular VSD closure. The procedure was guided by transesophageal echocardiogram, placing a 12-mm Amplatzer Ò VSD device to fully close the defect, without cardiopulmonary bypass support. The procedure terminated successfully, extubating the patient in the OR, without the need for blood transfusion with no other immediate complications. The patient was admitted to the PICU with minimal respiratory and inotropic support, with a stable and favorable evolution. No arrythmias nor bleeding presented within the first days after the procedure. Hemodynamic improvement was evidenced with echocardiogram which showed decreased tricuspid regurgitation and decreased pulmonary pressure. The patient was discharged eight days post surgery with minimal diuretics, aspirin, and phosphodiesterase inhibitors dose. This case is relevant, because it shows how religious beliefs can change the management of congenital heart defects. The surgical closure of the defect with a patch would be the first approach to resolve the defect, but the need for blood transfusion limited this possibility. The placement of a VSD device occluder with a hybrid approach was a suitable alternative considering the location of the defect and the borders for the correct implant of a metallic device by a perventricular puncture without the need of blood transfusions nor cardiopulmonary bypass; giving the family a relative low-risk procedure with physical, psychological, and spiritual safeness. Background: Transcatheter pulmonic valve implantation (TPVI) is a minimally invasive procedure that treats mechanical dysfunction of the pulmonic valve (PV) or right ventricular to pulmonary artery conduit. TPVI procedures have traditionally been performed under general anesthesia (GA). However, similar to other structural interventions, conscious sedation (CS) has emerged as an alternative to GA. The purpose of this study was to assess the efficacy and safety of CS-TPVI. Materials and Methods: We performed a retrospective review of 19 consecutive patients undergoing TPVI with CS or GA. The primary efficacy endpoint was procedural success, defined as residual gradient \ 20 mmHg and freedom from reoperation within 30 days. Secondary efficacy and safety outcomes included the procedure duration, 90-day all-cause mortality and 30-day hospital readmission rates, procedure characteristics, and periprocedural complications. Results: Nineteen patients underwent TPVI, eight of which received CS. The procedure success rate was not statistically different between GA and CS cohorts; one case in the GA-TPVI group had an elevated transvalvular gradient of 24 mmHg. The CS-TPVI 90-day all-cause mortality and 30-day hospital readmission rates were 0%. Median inroom procedure time was less with CS than GA (132 min (92-170, IQR) versus 196 min (179-234, IQR), p = 0.008). There were no differences in procedure or valve delivery durations, contrast use, radiation exposure, length of stay, or periprocedural complications between groups. Conclusions: In a single-center experience, the use of CS for TPVI was safe, less-invasive, and more efficient than GA. Our study demonstrates the importance of a multidisciplinary approach in complex congenital heart disease patients and underscores the need for larger studies investigating CS-TPVI. is an important hemodynamic variable in adult patients with a Fontan circulation. Risk factors that are associated with an elevated SVEDP have not been clearly identified in this patient population. Methods: All patients [ 18 yo with a Fontan circulation who underwent cardiac catheterization at our center between 1/08 and 3/19 were included. Relevant patient variables were extracted, and statistical analysis was performed to identify patient variables that were associated with SVEDP measured at catheterization. Results: Forty-two patients were included with a mean weight of 72.4 kg ± 19.5, mean age of 26.3 years ± 8.5, and a mean BMI of 25.6 kg/m 2 ± 6.2 at the time of catheterization. Ten (23.8%) patients had a systemic right ventricle (RV) and 5 (11.9%) had undergone a Norwood operation. The mean SVEDP was 11.1 mmHg ± 3.5 and mean pulmonary artery pressure was 16 mmHg ± 4.0. On univariate analysis, SVEDP was positively associated with BMI (p \ 0.01), age [ 25 yo (p = 0.04), taking diuretics at time of catheterization (p \ 0.01), taking sildenafil at time of catheterization (p \ 0.01), symptoms of heart failure(p \ 0.01), systemic ventricular systolic pressure (p = 0.03), pulmonary artery mean pressure (p \ 0.01), and systemic vascular resistance (p \ 0.01). The SVEDP was negatively associated with aortic saturation (p \ 0.01). On multivariate analysis, Children's Hospital of New Orleans, New Orleans, USA. 2 LSU Health, New Orleans, USA Abstract Background: As pediatric cath lab nurses, we explain every process in a step by step sequential manner, to patients and parents prior to proceeding with any procedure. We are compassionate and caring towards every child as if they were our own. However, families still tend to be apprehensive about entrusting their children to stranger providers and children also appear to be anxious prior to being escorted to strange cath lab environments with new provider faces. Two years ago, the Cardiovascular Surgical team implemented the EASE application for patients and families. This EASE (Electronic Access to surgical events) app is installed on a family member's cell phone and allows any team member to send free text, photos, and video updates during and after the procedure. This improved the realtime communication between team members and families, and hence was very beneficial for enhancing the provider-patient trust relationship and reducing the anxiety associated with these procedures. Objective: In May 2020, two state-of-the-art new cath labs opened doors to meet the growing demand of an ever increasing diverse Pediatric cardiac population. This was felt to be an opportune moment to introduce both new and prior families to the brand-new space. And, from the positive feedback received from the EASE app, we wanted to further enhance the family experience and ease the anxiety by showing them the cath lab environment as well as sharing the experience of undergoing anesthesia through a digital media presentation. Materials and Methods: A virtual tour of a patient who will undergo a catheter procedure will be filmed from the time of check-into discharge and will mimic the actual day of the procedure. All staff will be introduced through a taped meet and greet session. This instructional video will be shot in English medium and posted on our Heart Center's web page as well as the hospital's affiliated web-based resources for all families to view. To cater to diverse populations with various socioeconomic backgrounds, a designated tablet will be supplied to all patients and families to view this introduction video upon admission as well. All families will be surveyed with a brief questionnaire about their experience with the digital media presentation. Results and Conclusions: The survey will include families over a three month period and the data to showcase the positive effects of integrating digital media technology into the patient/family cath lab experience will be reported at the upcoming PICS-AICS session. We describe the short-term results for transcatheter tricuspid valve-in-valve implantation (TVIVI) using the Melody valve (Medtronic, Minneapolis, MN) in patients with stenosis of a previously placed bioprosthetic valve in the tricuspid valve position who were deemed high-risk surgical candidates. Methods: A retrospective chart review was undertaken of patients who underwent TVIVI at our institution between 2016.and 2020. Baseline clinical characteristics, procedural details, and outcomes at 1 month, 6 months, and 1 year were reviewed. Statistical analyses (dependent t test) to assess tricuspid valve gradients before and after TVIVI and at 1, 6, 12, 24 months of follow-up were performed. A p value \ 0.05 was considered significant. Results: Four patients, ages 17 to 66 years (37.5 ? 10.2; mean ? SEM), identified to have severe stenosis of a previously placed bioprosthetic valve in the tricuspid position underwent TVIVI with a 22-mm Melody valve. Three patients were NYHA functional class 4 and 1 patient was class 3 prior to intervention. All patients had multiple associated comorbidities and were considered high risk for cardiac surgery. Cardiac catheterization data obtained prior to and after TVIVI demonstrated that the peak-to-peak gradient across the tricuspid valve decreased from 14.5 ? 3.3 to 5.25 ? 1.25 mmHg (mean ? SEM; p value = 0.02). By echocardiogram the mean gradient across the tricuspid valve decreased from 12.0 ? 1.41 to 5.0 ? 1.08 mmHg (mean ? SEM; p value = 0.007). The mean transvalvar gradient by echocardiogram was unchanged at a follow-up of 3-25 mo (5 ? 4.3; mean ? SEM). One patient underwent Melody valve placement in the pulmonary valve position during the same procedure. The only complication was transient complete heart block in one patient, which resolved within 12 h. No other complications were identified at a mean follow-up of 5 months. Hospital length of stay ranged from 1 to 13 days, with a mean of 4.5 days (SEM ? 2.8). Cardiovascular symptoms resolved in 3 patients and 2 patients had improvement in NYHA functional class. One patient, with a functional single ventricle (unbalanced AV septal defect, severe AV bioprosthetic valve stenosis) had liver cirrhosis, chronic ascites, and deteriorating renal function. Following TVIVI, he had improvement in renal function and is now listed for heart and liver transplant. Conclusion: Patients undergoing tricuspid valve replacement (TVR) using bioprosthetic valves are at a risk for valvar degeneration and may need repeated interventions for tricuspid valve stenosis or regurgitation. Surgical replacement of the valve may be associated with significant morbidity and mortality in patients with poor functional class and multiple comorbidities. Our experience thus far suggests that TVIVI is a safe and effective alternative to surgical TVR without valvar restenosis or regurgitation at short-term follow-up. TVIVI may obviate the need for surgery or delay in intervention, and should be considered as the treatment of choice in select patients. Optimal Criteria of Transcatheter Closure of Fontan Fenestration-A Single-Center Experience with a Review of Literature Yuki Kawasaki 1,2 , Takeshi Sasaki 1,2 , Thomas Forbes 1 , Robert Ross 1 , Daisuke Kobayashi 1 for effective transcatheter closure of fenestration to avoid both of acute and chronic Fontan failure have not been clarified enough. The objective of this study was to describe the hemodynamic data with test occlusion of the Fontan fenestration between closure and non-closure patients along with subsequent development of Fontanassociated diseases (FAD) at follow-up. Methods: This was a retrospective study to assess the outcome of Fontan fenestration closure at Children's Hospital of Michigan over 27 years . The inclusion criteria were patients undergoing cardiac catheterization for an indication of fenestration closure. The data were compared between two groups: closure vs. non-closure. Baseline characteristics and hemodynamic variables with the fenestration occlusion test were analyzed. The primary outcome was the development of the composite events of death/transplant, deteriorated NYHA or FAD. Results: Among the 38 patients who were brought to the catheterization laboratory, 33 received fenestration closure and 5 did not. On a median follow-up of 3.4 years (range 1 month to 12.6 years), the incidence of primary adverse outcomes was 13% (5/38). The incidence of primary outcome was significantly higher in the non-closure group (60% vs. 6%, p \ 0.01). The non-closure group had a higher incidence of moderate or severe atrioventricular valve regurgitation, NYHA class III symptoms, use of ACEI/ARB, furosemide, and sildenafil. Multivariable logistic regression model showed that the hemodynamic variables associated with non-closure group were mean left atrial pressure (odds ratio 1.74, p \ 0.05) and change of mean Fontan pressure at the balloon occlusion (2.2, p \ 0.05). Conclusions: The judgment for the fenestration closure appeared appropriate in our cohort. Fontan fenestration closure may not be advisable with a high baseline left atrial pressure or a significant increase of Fontan pressure on balloon occlusion testing. Marco Ruiz-Ontiveros, Alejandro Flores-Arizmendi, Antonio Salgado-Sandoval, Jesus Montalvo-Aguilar, Enrique Zuñiga-Guerrero National Medical Center ''20 de Noviembre'' ISSSTE, Mexico City, Mexico Abstract Introduction: Transcatheter creation or dilatation of a fenestration after a Fontan procedure is described to improve clinical condition when patients present deterioration with development of proteinlosing enteropathy, pleural effusion, ascites, or plastic bronchitis. Another complication present in the short and long term is the multiple type of arrhythmias, the treatment can be pharmacological or in some cases may need an ablation or in rare cases the use of pacemaker. Case Report: Male of 18 years old, with diagnosis of tricuspid atresia, fenestrated Fontan surgery on June 2019, one year later, the patient presented with clinical deterioration, with bilateral pleural efussion and ascites, in the echocardiogram with no obstruction in the Fontan but with no evidence of fenestration. We decided to make a percutaneous fenestration in the extracardiac conduit. Under general anesthesia and mechanical ventilation, we obtain femoral access. There were no obstructions in any site of the Fontan circuit but the mean pressure was 25 mmHg, in the angiography with no evidence of the surgical fenestration, so with a Brockenbrough needle advanced through a 6 Fr long sheath to the selected perforation site of the extracardiac conduit, a PT choice 0.014 coronary wire was advances through the needle and the right atrium and positioned in the left atrium, next, the needle, and the dilator of the long sheath were carefully exchanged for a 5-mm balloon catheter to pass and dilate the conduit and the atrial wall. Afterwards, the balloon catheter was exchanged for a 7-mm and then a 10-mm balloon catheter to further gradually dilate the initially established communication. In the subsequent days, the patient presented a complete AV block, with the indication of colocation of a pacemaker, because of the risks, we decided a transcatheter implantation and the only access was the recent perforation, but the cables would obstruct almost the whole fenestration. The second procedure was performed in similar conditions, the previous fenestration was permeable, also with a Brockenbrough needle the second perforation was made above the first one, and the balloons catheters used to dilate were 6, 8, and 10 mm. We left the coronary wire to advance de pacemaker and position it at the atrium and left ventricle. After the procedure the patient's clinical condition improved considerably, the control EKG demonstrated the normal function of the pacemaker. Conclusion: We present a rare and success case of a double-transcatheter perforation in a Fontan conduit, the first one to improve the clinical condition (pleural effusion an ascites), and the second one to place a bicameral pacemaker because of a complete AV block with hemodynamic repercussion. The patient improved his functional capacity and he egress with no evidence of effusions. Background: Transcatheter electrosurgery uses radiofrequency energy to cut tissue using off-the-shelf guidewires and a standard electrosurgery unit. Recent adult structural heart applications include transcaval access, BASILICA, and LAMPOON. Non-surgical, transcatheter vessel anastomosis is a potential congenital heart disease application. Methods: Radiofrequency energy from a standard electrosurgical generator (System 5000, Conmed, Utica, New York) was used with commercial 0.014 00 guidewires (Astato, Asahi Intecc, Santa Ana, California) to cross vessel walls for large vessel end-to-side anastomosis, rescue re-anastomosis between adjacent vessels, and temporary anastomosis between non-adjacent vessels for vascular access. Results: Transcatheter electrosurgery was successful in enabling anastomosis of donor vessels measuring 16.7 mm-19.0 mm in diameter to recipient vessels measuring 10.2 mm-19.6 mm in diameter. Vessels were 0-20.2 mm apart. In an adult congenital heart disease patient, superior vena cava exit and right pulmonary artery entry followed by subsequent endografts created a permanent superior cavopulmonary anastomosis with anastomotic diameter of 20.7 mm. In a second (pediatric) patient, transcatheter rescue re-anastomosis was performed after inadvertent right pulmonary artery occlusion following transcatheter pulmonary valve insertion. Distal endograft wire perforation from the main pulmonary artery followed by balloon angioplasty created a 7.0 mm anastomosis with 6 mmHg residual pressure gradient into the right pulmonary artery while preserving implanted valve function. In a third case, transcatheter electrosurgery established temporary (''transcaval'') vascular access between the inferior vena cava and abdominal aorta (spaced 20 mm apart) in a patient with insufficient arterial vascular access. This facilitated temporary 20 French arterial access for endograft placement to dilate a stenotic surgical interposition graft and exclude a compressive seroma. There were no procedural transcatheter electrosurgery complications. All three patients were extubated immediately after their procedures. The superior cavopulmonary anastomosis patient was hospitalized for 112 h (4.6 days) while the other two patients were hospitalized for 36 and 37 h, respectively. At time of most recent follow-up (576 ± 458 days), there were no complications. Conclusions: Transcatheter electrosurgery can be used safely for large vessel end-to-side anastomosis, rescue re-anastomosis, and temporary anastomosis for vascular access. We demonstrated success in directly adjacent vessels as well as more remote vessels requiring traversal of extra-vascular space. Wire traversal was performed through native, naïve vessels, and synthetic material (Melody, Medtronic, Minneapolis, Minnesota). Kristin Oshiro, Mariel Turner, Alejandro Torres, Matthew Crystal, Julie Vincent, Oliver Barry NewYork Presbyterian Morgan Stanley Children's Hospital, New York, USA Abstract Background: COVID-19 has led to major changes in hospital systems across the world. In an effort to reduce viral transmission, conserve resources, and in accordance with institutional and state mandates, all elective procedures and surgeries were postponed during the initial outbreak. Guidelines for case selection are limited and management for pediatric catheterization laboratories during this crisis is unprecedented. Objectives: To report the protocols and case selection of a highvolume pediatric cardiac catheterization laboratory in the epicenter of the novel coronavirus (COVID-19) pandemic. Methods: All pediatric cardiac catheterization procedures from March 16 through May 10, 2020 were reviewed. Changes to case selection and periprocedural workflow were described. Data were collected on COVID-19 testing status, primary procedure type, and all procedures were classified by urgency. Results: There were 52 catheterization procedures performed on 50 patients. Endomyocardial biopsies were the most common procedure (n = 27, 52%). Interventional and diagnostic procedures represented 27% (n = 14) and 21% (n = 11) of cases, respectively. Two emergent procedures (3.8%) were performed on patients with positive COVID-19 testing. Most cases were performed on patients with negative COVID-19 testing (n = 33, 94%). Conclusions: Adjusting to the COVID-19 pandemic in a high-volume pediatric cardiac catheterization laboratory can be safely and effectively managed by prioritizing emergent and urgent cases and modifying workflow operations. The experience of this center may assist other pediatric cardiac catheterization labs in adapting to similar practice changes as the pandemic continues to evolve. Evan Zahn, Eason Abbott, Neil Tailor, Shyam Sathanandan, Dustin Armer Cedars-Sinai Medical Center, Los Angeles, USA Abstract Background: There are no endovascular stents designed or approved for use in infants and neonates, nor is there a stent capable of being implanted at neonatal diameters and achieving adult size while maintaining structural integrity. The Renata Minima stent was designed specifically to address these issues. Methods: The Minima stent is a balloon expandable, cobalt-chromium stent that comes pre-mounted on a proprietary 4F covered delivery system designed to track over a standard 0.014 00 or 0.018 00 guidewire. Bench-top expandable diameter ranges from 4 to 22 mm. This study was performed in 6 infant pigs to examine 1) deliverability and implant performance, 2) early histopathologic pathologic response, 3) in vivo re-dilation potential and stent behavior, and 4) chronic histopathologic pathologic response in both re-expanded and non-re-expanded stents. This study utilized final stent designs, however, some manufacturing processes were modified between experiments. Results: Twenty-four stents (22 Minima and 2 control) were implanted into the aorta (n = 13), branch pulmonary arteries (n = 6), and central veins (n = 5) of 6 infant piglets with an average weight of 4.6 kg. One piglet had an LPA stent which migrated to the MPA and underwent no further instrumentation and is not included in subsequent analyses. The remaining piglets were divided into 3 categories: 1) Early feasibility, single re-expansion, and sacrifice at 1 month (n = 2 piglets, 10 stents); 2) Serial re-dilation performed at 2-3 mos and 5 mos after implant (2 piglets, 9 stents); and 3) Single dilation 5 months after implant (1 piglet, 4 stents). All stents were successfully deployed into the target vessel, excluding 1 branch pulmonary artery stent, which utilized an early delivery system prototype. There were 2 early instances of proximal LPA stent migration following successful deployment during removal of the delivery balloon. Median implant diameter was 7.5 mm (2.6-8.8 mm). Stents were reexpanded at 34, 64, 82, and 154 days, corresponding to average animal weights of 14, 35, 44, and 107 kg. All Minima stents regardless of location could be re-dilated to keep pace with somatic growth (Figure) . There was a single Minima stent that appeared incompletely opposed to the abdominal aortic vessel wall 64 days after implant. Histopathology at 34 and 146 days (3 animals, 8 vessels) demonstrated widely patent stented vessel lumens with uniform stent apposition to vessel wall, early (1 mos) mild inflammatory response surrounding stent struts, typical progressive vascular healing response, and a progressive smooth neointimal growth pattern covering stent struts over time (2-3 mos). Conclusions: This early work suggests that the Minima stent and 4F delivery system may be well suited for treatment of a variety of vascular stenoses in young infants and neonates. This is a unique device in that it can be enlarged in vivo, from neonatal to adult diameters while maintaining structural integrity. Further laboratory and clinical testing will be needed to determine the safety and efficacy of this novel device in humans. Do you think we need to add a blurb like this about the varying manufacturing processes-which led to the inability to grow past 18 mm and accounted for higher recoil in some stents? I like it This stent was one that was left in the vessel for 5 months without re-expansion Fixed this…I think The exact quantity of sirolimus in each stent was known. Results: Twelve neonates with median age of 5.5 days received sirolimus-eluting stents, one stent in nine and two in the rest. The lesions were pulmonary atresia intact ventricular septum(PAIVS) in four, univentricular lesions with pulmonary atresia in four, biventricular lesions with pulmonary atresia in three, and right ventricular rhabdomyoma in one neonate. If single stents up to 22 mm length, 24-hour drug levels were less than 5 ng/ml. Even though 24-hour levels were above 5 ng/ml in patients with single longer stent or two stents, it reduced to very low levels by seventh day. Christopher Herron, Daisuke Kobayashi Children's Hospital of Michigan, Detroit, USA Abstract Background: Pericardiocentesis is the invasive percutaneous procedure for acute and chronic excessive accumulation of pericardial fluid. The hypothesis of this study was that pericardiocentesis be effective and safe in children with low risk of complications and certain clinical factors be associated the development of significant adverse events (SAE). Objectives: To describe the single-centered experience of pericardiocentesis over the 20-year period (2001 to 2020) and evaluate the effectiveness and safety of pericardiocentesis and factors associated with development of SAE. Methods: This was a single-centered retrospective study to describe all the children aged B 20 years who underwent pericardiocentesis at the bedside and in the cardiac catheterization laboratory. Data on demographics, etiologies of pericardial effusion, repeat intervention at follow-up were collected. Technical procedural success was defined as satisfactory removal of effusion at pericardiocentesis. Logistic regression model was used to evaluate the factors associated with development of SAE and repeat intervention. Results: A total of 127 patients underwent 153 pericardiocentesis procedures. The mean age was 6.5 ± 6.7 years with weight of 27.8 ± 28.6 kg. Most common etiology was post-pericardiotomy syndrome (n = 56, 44%), followed by Infectious (12%), Malignant (10%), and Iatrogenic (9%). Clinical and echocardiographic cardiac tamponade were present in 53% (80/153). Pericardiocentesis was performed primarily in the catheterization laboratory (n = 86, 59%) and in the high acuity (emergent 9%/urgent 91%). Concurrent pericardial drain placement was performed in 67 patients (53%) at the initial pericardiocentesis. Acute procedural success was 93%. Repeat intervention was performed in 33 patients (26%). The incidence of SAE was 5% (7/149): hemopericardium requiring emergent surgery (n = 2), hemopericardium with hypotension (n = 2), seizure with anesthesia induction (n = 1), right ventricle puncture with needle (n = 2). No identifiable risk factors were associated with SAE. Conclusions: Pericardiocentesis was life-saving in children with its high effectiveness and safety even in emergent and urgent situations. Although initial pericardiocentesis was effective, one of four patients required reintervention for recurrent pericardial effusion. Christopher Herron, Thomas Forbes, Daisuke Kobayashi Children's Hospital of Michigan, Detroit, USA Abstract Background: Percutaneous balloon pericardiotomy (PBP) is a percutaneous procedure that creates a window in the parietal pericardium by balloon angioplasty. The use of PBP has not been reported well in children. Objectives: The objective of this study was to describe the singlecenter experience of PBP in children. Methods: This was a retrospective study to describe all the children aged \ 20 years undergoing PBP during an 18-year period (2001 to 2019). Patient characteristics, technical and ultimate procedural success, and repeat interventions were collected. Results: A total of 13 PBP's were performed in 11 children at the median age of 12 years (range 1.8 to 19). The etiologies of pericardial effusion were post-pericardiotomy syndrome (n = 4), restrictive cardiomyopathy (n = 1), autoimmune diseases (n = 3), malignancy (n = 2), and idiopathic (n = 1). Two patients received two PBP. The technical success of PBP was 100% with no acute adverse events (balloon rupture or local bleeding). Five (45%) required reintervention and ultimately 3 required a surgical pericardial window 6 to 35 days after the PBP. As a result, ultimate procedural success rate was 73% (8/11). Conclusion: PBP was performed safely with high technical success in children. PBP may be considered for recurrent and persistent pericardial effusion, before considering a surgical pericardial window. Figure 1 ), Masson trichrome, and for smooth muscle actin. IVUS images were correlated with histologic findings. Results: The median age at death was 10 months (range: 4-21) and median postmortem weight was 4.7 kg (range: 3.91-9.58). Three had primary PVS, 2 congenital heart disease (1 TAPVC), and 1 prematurity/chronic lung disease. PVS veins previously underwent a median of 5 surgical/transcatheter interventions (range: 4-12) with recurrent stenosis extending into segmental branches on last angiography. In PVS veins, IVUS demonstrated wall thickening with up to two layers of variable echogenicity, often with indistinct borders. Histologically, the veins showed fibroblastic proliferation with areas rich in myxoid matrix as well as areas with abundant collagen and elastic fibers. Discrete vein layers were obscured by scarring and elastic degeneration. A lower reflective periluminal layer by IVUS corresponded with hyperplasia of myofibroblast-like cells in abundant myxoid matrix (Figure 1a /b/c. marked *, C = IVUS catheter). The hyper-reflective layer by IVUS extended to the outer edge of the vessel and corresponded to a less myxoid layer with more collagen, smooth muscle, and elastic fibers (Figure 1a /b/c. marked #). The outer less reflective edge of the IVUS image correlated with a gradual transition into adventitia. Normal veins had a thin wall, correlating with histologically normal cellular and extracellular components, without intimal proliferation (Figure 1d , M = striated muscle). Conclusion: Our in vitro study identifies the histologic correlates to IVUS-defined areas of intraluminal PVS. IVUS may provide further understanding of the anatomy and mechanisms of pediatric pulmonary vein obstruction. Hannah Methods: We analyzed pre-Glenn X-ray contrast angiography (XA), cardiac computed tomography (CT), and cardiac magnetic resonance (CMR) studies. Results: Over an eleven-year period (1/2007-6/2017), 139 Glenn surgeries were performed at our institution. The typical age range at surgery was 59-371 days (median = 163; IQR = 138-203). Eightnine XA, ten CT, and ten CMR studies obtained from these patients were analyzed. Cephalad SVC measurements (millimeters) were 7.3 ± 1.7 (XA), 7.7 ± 1.6 (CT), and 6.9 ± 1.8 (CMR). RPA measurements were 7.3 ± 1.9 (XA), 7.4 ± 1.6 (CT), and 6.6 ± 1.9 (CMR). Potential device lengths were 10.9 ± 6-17.4 ± 6.4 (XA), 10.1 ± 2.1-17.7 ± 2.4 (CT), and 17.3 ± 4-23.7 ± 5.5 (CMR). SVC-RPA angle (degrees) was 132.9 ± 13.2 (CT) and 140 ± 10.2 (MRI). Image quality of all CT (100%), almost all XA (SVC 100%, RPA 99%), and most MRI (SVC 80%, RPA 90%) were deemed sufficient. Parametric modeling virtual fit device with 10 mm diameter and 20-25 mm length was ideal. Conclusions: Ideal transcatheter cavopulmonary shunt device for the typical patient would be 10 mm in diameter and 20-25 mm in length. Najib AlRawahi 1 , Ghaliah Al Muhaini 1 , Mohammed AlRawahi 1,2 1 National Heart Center, Muscat, Oman. 2 Sultan Qaboos University Hospital, Muscat, Oman Abstract Since 2008 implantable Cardiac Resychronization devices have been implanted exclusively in our center. We describe our experience in successful implantation of the left ventricular lead from 2015 to 2019. Our approach is using EGMs from a quad electrophysiology catheter which is successful in 96% of the cases. For the remaining cases, our approach is using different shapes of conventional diagnostic coronary catheters in localization of the Os then advancing a guide wire into the coronary sinus. Our stepwise approach was successful in 99% of the cases. For the remaining 1% complication of CS dissection was done which warrants a second procedure during which the implantation is done. We would like to share our approach to the world. is at high risk for cardiovascular diseases in early adulthood and has been shown to have increased AS compared to term infants. A patent ductus arteriosus (PDA) is a modifiable risk factor, common in premature infants, known to negatively impact AS. Aim: The aim of this study was to investigate if transcatheter closure of a PDA in the premature infant population had an effect on the aortic stiffness index. Methods: This is a single-center, retrospective study of all consecutive premature infants who underwent successful transcatheter PDA closure between 05/2019 and 02/2020. Aortic stiffness adjusted to body surface area (ASb) was calculated using the formula [(systolic blood pressure/diastolic blood pressure)*((Aortic systolic diameteraortic diastolic diameter)/aortic diastolic diameter)]/body surface area. Measurements of the aorta were done using 2D echocardiography with a simultaneous blood pressure cuff recording. Regional ASb was recorded at the ascending aorta at the level of the right pulmonary artery (AscAo), transverse aorta between the innominate and left common carotid artery (TransAo), and descending aorta immediately distal to the isthmus (DistAo) from the long-axis suprasternal view. The proximal ascending aorta was also measured in the parasternal long-axis view above the sinotubular junction (PLXAscAo). Each regional ASb was recorded within one week prior to PDA closure, then post closure at one week and one month. Left ventricular dimensions and systolic function were measured on each study using M-mode and 5/6 area-length (AL). Statistical data are described using standard statistics and comparisons were made using unpaired two sample t test. Results: Seventeen premature infants underwent successful transcatheter PDA closure during our study period. Objective: Cardiac troponin I release is associated with myocardial injury and has prognostic value in pediatric patients undergoing congenital heart surgery. There is little known data about troponin leak after cardiac catheterization in the pediatric population with the current high-sensitivity troponin I assay. We hypothesized that there would be differential troponin elevation with diagnostic, interventional, and endomyocardial biopsy procedures. The objective of this study is to compare troponin I release in pediatric patients undergoing diagnostic, interventional cardiac catheterization and endomyocardial biopsies and to establish norms following these procedures. Methods: Prospective, single-center study of patients undergoing pediatric cardiac catheterization procedure between July 2019 and May 2020. Patients who met inclusion criteria were consented and enrolled in this study. Patients were divided into one of three groups: diagnostic, interventional cardiac catheterization, or endomyocardial biopsies. Troponin I samples were obtained prior to and immediately after the procedure. Electrocardiography was preformed post procedure to evaluate for ischemic changes. Demographic and clinical data were extracted from electronic records. The pre-procedural, postprocedural, and the difference between pre and post-procedure troponin I levels were analyzed between groups using non-parametric tests. Results: Fifty-one patients, underwent a total of 62 procedures. There was a significant difference in post-procedure troponin I level between groups (p \ 0.001). Diagnostic cardiac catheterization (n = 7) demonstrated minimal troponin release with no values exceeding upper threshold post procedure (median 0.012, IQR 0.012-0.012). Endomyocardial biopsies (n = 31) were associated with the highest elevation in troponin I level (median 0.2, IQR 0.114-0.259) compared to interventional cardiac catheterization procedures (n = 24, median 0.064, IQR 0.026-0.154). No procedurerelated complications occurred during this study. Conclusion: Utilizing a high-sensitivity troponin I assay, significant troponin elevation is detected in all pediatric patients undergoing endomyocardial biopsies and most patients undergoing interventional procedures. There was no significant troponin elevation following diagnostic heart cath procedures. Understanding the norms of troponin I release with each type of procedure can be useful to evaluate the myocardial health particularly if there is a concern for complications during the procedure. Baseline patient and procedural characteristics were compared, in addition to outcomes, and were analyzed using SPSS. Results: Seventy-four consecutive PC procedures were performed in 63 patients. Two procedures were excluded secondary to emergent nature without availability of ultrasound or echocardiographic guidance. Thus, 72 procedures were analyzed, of which 48 were performed using the PLANE technique and 24 using ECHO technique. There was no procedural mortality among either group. One minor complication was noted, asymptomatic small pneumopericardium that resolved with aspirating from pericardial drain. No significant differences in baseline characteristics ( (8) newborns with duct-dependent pulmonary blood flow. Background: Stenting of the DA in newborns with duct-dependent pulmonary blood flow is still challenging mainly due to the variety, ductal origin, morphology, and tortuosity of the ductus in these patients. Thus, we developed a novel ductal guide catheter with a shape specially designed to ease the palliative procedure in a wide variety of challenging DA. Methods: Commercial guide catheters were modified through thermoforming into the ductal guide catheter shape. These were used for stenting of the DA in newborns with duct-dependent pulmonary blood flow treated at the Congenital Heart Disease Institute at Fundación Cardioinfantil (FCI) between 2017 and 2020. The decision to use the ductal guide catheter was made by the interventional pediatric cardiologist according to the patient's medical status, the DA characteristics, and the diagnostic catheterization at the beginning of the procedure. The intraprocedural outcomes, clinical data, and the DA morphological characteristics were analyzed for each patient. The use of the ductal guide catheter was approved by the FCI's ethical review committee and required informed consent. Results: Eight (8) patients were analyzed. Ages ranged from 1 to 55 days (median = 6), and weight ranged from 2.4 to 4 kg (median = 2.95). Arterial blood oxygen saturation previous to the procedure ranged from 60 to 99% (median = 93.75). Two patients had a diagnosis of pulmonary stenosis, two had pulmonary atresia with ventricular septal defect, three had pulmonary atresia with intact ventricular septum, and one had pulmonary atresia with single ventricle morphology. Only one patient had a procedure prior to stenting. Four DA had aortic insertions at the aortic arch and four at the descending aorta. Six DA had a type 2 shape, one a type 3 shape, and one a type 1 shape according to the Qureshi et al. classification scheme. Angiography images of the eight ductus are presented in Figure 1 . DA minimum diameter ranged from 1.6 to 5.11 mm (median = 2.41). Transductal gradient previous to procedure ranged from 13 to 90 mmHg (median = 41.5). Pulmonary arteries size ranged from 2.9 to 5.1 mm for the left pulmonary artery (median = 3.80) and 2.83 to 5 mm for the right pulmonary artery (median = 4.22). McGoon indexes ranged from 1.13 to 1.91 (median = 1.41). Femoral artery access was used in all the patients, however, the shape of the ductal guide catheter can be used for alternative vascular accesses that will be used in future interventions. No concomitant procedures were performed. The procedure was successfully completed in all patients and only two patients had minor complications, which were successfully controlled. Procedure time ranged from 59 to 262 min (median = 77). Patients required from 1 to 4 stents (median = 2). A total of 17 stents with either 3.5 or 4 mm diameter were used. All patients were monitored 4 to 207 days (median = 15) after the procedure was performed. Only one patient evidenced non-restrictive flux through the stent at follow-up. Conclusions: Performing stenting of the DA as the first palliative procedure in newborns with duct-dependent pulmonary blood flow continues to be a challenge due to the patient's critical medical condition and the complexity of their DA. Nevertheless, our novel ductal guide catheter allowed successful stenting of the DA in all the patients evaluated due to its specially designed shape. We are developing in vitro models of various DA anatomies to further test the versatility of our ductal guide catheter. Background: Transcatheter intervention for coarctation of the aorta (coA) has become standard therapy in larger patients and in patients with recurrent coarctation (re-coA). Studies have been published detailing the outcomes of catheter-based interventions for coA but none have focused on patients less than 25 kilograms (kg). The aim of our study was to describe our center's short and medium-term outcomes in this patient population. Methods: A retrospective review of patients less than 25 kg who underwent interventional cardiac catheterization for coA from 2000 to 2019 at our center was performed. Results: One hundred and thirty-four patients underwent 182 transcatheter interventions for coA between January 2000 and December 2019. The median age (IQR) at cardiac catheterization was 7 months (29) and median weight (IQR) was 7.1 kg (7.9). Sixty-three patients (47%) had undergone single ventricle (SV) palliation and underwent 92 (51%) of the procedures. Of these procedures, 24 (26%) used a prograde approach, 66 (72%) a retrograde approach, and 2 (2%) used both approaches during the same procedure. The retrograde approach was via the femoral artery in all but 3 patients in which the carotid, axillary, or subclavian arteries were used. Of the total 182 interventions, 142 (78%) were for re-coA and 40 (22%) were for native coA. Balloon angioplasty alone was performed in 147 of 182 (81%) and stent placement occurred in 35 of 182 (19%) procedures. During a median follow-up of 40 months, 59 (44%) patients required reintervention: 44 (75%) for re-coA and 15 (25%) to maximize stent diameter. Twenty-five of the 44 patients with re-coA (57%) underwent surgical repair. There were 9 (4.9%) procedural complications including pseudoaneurysm of the coA site (1), second-degree atrioventricular block (1), post-procedure seizure (1), balloon rupture (1), aortic dissection (1), right external iliac artery transection (1), and cardiac arrest requiring CPR (3). There were no deaths related to the procedure. Post-procedural ultrasound of the accessed artery was performed after 21 (12%) procedures, with 11 arterial occlusions documented. Conclusion: We describe a large cohort of patients who underwent transcatheter intervention for coA weighing less than 25 kg. These procedures may be safely and effectively performed in this group of patients as an alternative to surgical intervention. The need for reintervention is common. Agios Loukas Clinic, Thessaloniki, Greece. 2 Iatrikon Medical Center, Athens, Greece. 3 Agia Sophia Children's Hospital, Athens, Greece. 4 Agia Sophia Children's Hospital, Athens, Greece. 5 AHEPA University General Hospital, Thessaloniki, Greece Abstract Background: During the last years, catheter closure of perimembranous ventricular septal defect (PMVSD) has been increasingly performed using a variety of modified Amplatzer asymmetric PMVSD occluders with satisfactory short-term results and safety. However, long-term results with the use of these devices are missing. We present 10-year follow-up (FU) with 95 patients (pts) with perimembranous ventricular septal defects (PMVSDs) who underwent transcatheter closure at 3 Institutions using the Amplatzer asymmetric PMVSD occluder. Methods: The age of the pts ranged from 0.5 to 12 years. During the study period, 35 other patients were excluded from transcatheter closure because they did not fulfill the patient selection criteria (distance less than 2 mm from the PMVSD to the aortic valve, size of VSD in relation to patient's age). Results: The device was permanently implanted in 87/95 (92%) patients. Complete occlusion of the communication at six month was observed in 83/87 (95%) patients. Main complications included, Early: a. Device embolization (3 patients-catheter and surgical removal, respectively), b. severe procedural bradycardia (5 pts), and c. Mobitz II and complete heart block heart in 3 and 1 patients, respectively (observed in patients less than one year of age-body weight \ 8 kg). (sinus rhythm after device removal). Late (follow-up 2-10 years): Complete heart block (required pacemaker implantation) was developed in one patient of 3 years old with posterior atrioventricular canal-type defect, no other patient developed heart block during the follow-up. Three patients developed mild aortic regurgitation, in one of them the regurgitation was not seen at the 1-year follow-up, no other complications were observed. Conclusions: Transcatheter closure using the original Amplatzer APMVSD occluder is a safe and effective non-surgical alternative that can be used in carefully selected patients with PMVSDs. Despite the large variety of currently available Amplatzer-like PMVSD occluders this revolutionary designed device is still the most appropriate one for catheter closure of PMVSDs. Abstract Introduction: Transcatheter closure of coronary fistula is an established procedure. However, closure of coronary fistula approaching from pulmonary artery side is considered difficult. We report transcatheter closure of coronary fistula via pulmonary artery using a double-guide wire technique. Procedure: A 28-year-old man with Klinefelter syndrome presented with recurrent chest pain over 2 years-associated with elevation of Troponin. Coronary angiograms performed 2 years apart showed two coronary fistulae. Fistula 1 had a bulbous portion (7 mm 9 15 mm) which was fed by a mesh of vessels from left anterior descending artery (LAD) and drained to main pulmonary artery (MPA). Fistula 2 was fed by an accessory vessel originating very close to right coronary artery (RCA), and supplied conal myocardium before giving off branches that drained to MPA. Decision was made to close the coronary fistulae. Fistula 1 (''F'' in Figure) was fed by very tiny mesh of vessels from LAD. Therefore, it was not possible to enter the fistula from left coronary artery. Therefore, decision was made to use a double-guide wire technique to enter from MPA side, 6 French JR4 guide catheter was used. First, a 0.014 00 coronary guide wire was passed to distal LPA (''1'' in Figure) . This wire stabilized the catheter tip. The catheter tip was pulled opposite to the drainage point of the fistula. A second 0.014 00 guide wire (''2'' in Figure) was advanced into the fistula and stabilized inside the bulbous portion of fistula. The first guide wire was pulled back and catheter tip advanced into the fistula. After confirmation of catheter position, a Microvascular Plug 7Q was delivered in position. Complete occlusion of fistula was confirmed by left coronary angiogram. Fistula 2 was fed by an accessory vessel next to origin of RCA (not shown in Figure) . First guide wire was advanced to distal RCA. Second guidewire was used to cannulate the accessory RCA vessel. Because this guide wire entered a different vessel than the feeder branch, a third guide wire was used to cannulate the feeder branch. When third guidewire was stabilized, the first two guide wires were removed and the catheter was advanced into the feeder branch. A Microvascular Plug 5Q was delivered using a microcatheter. Complete occlusion of fistula and the feeder vessels was confirmed by repeat angiogram. Patient was discharged home on Aspirin. Conclusion: Use of double-guide wire technique enabled cannulation of vessels that were in unfavorable positions. Closure of coronary fistula by approaching from main pulmonary artery was accomplished using double-guide wire technique. Methods: To evaluate in-hospital costs across U.S. hospitals, we conducted a retrospective analysis of patients undergoing TPV or SPV between January 1, 2017-December 31, 2018 using the Premier Hospital Database. Patients were included in the study if they underwent a TPV or SPV procedure based on ICD-10 procedure codes. Patients were matched 1:1 using propensity score method based on patient age, Charlson comorbidity index grouping (4 indices), gender, race, and payor type. In-hospital costs were defined as the total hospitalization cost including operating room, supply, room and board, ICU, lab, etc., plus pharmacy cost, adjusted to 2019 dollars. Results: We matched 490 TPV and SPV patients across 2017 and 2018 claims years. The average total inpatient hospital cost for TPV was 30% and 25% lower than the SPV comparator in 2017 and 2018, respectively (in 2018, TPV = $39,727, SD = $37,209 vs SPV = $53,313, SD = $28,492). The average total inpatient costs for TPV are lower than SPV, despite a higher average supply cost for TPV (in 2018, TPV = $38,763, SD = $21,547 versus SPV = $16,741, SD = $8095). TPV had lower average costs in many cost centers, including room and board (in 2018, TPV = $3833, SD = 8850 versus SPV = $14,294, SD = $10,747) and operating room (in 2018, TPV = $6392, SD = $7340 versus SPV = $14,116, SD = $7945). Average length of stay for TPV was 85% and 58% lower than SPV in 2017 and 2018, respectively (in 2018, TPV = 2.58 days, SD = 8.12 versus SPV = 6.09 days, SD = 5.31). Conclusion: TPV demonstrates lower hospital costs than SPV, with the lower length of stay and lower costs of multiple cost centers offsetting the higher supply cost for TPV. These cost data demonstrate the necessity of hospital valve programs to consider total overall hospital costs of SPV and TPV versus focusing on supply costs. Sanchitha Guruchandrasekar, Kiran Mallula, Ernest Siwik Louisiana State University, New Orleans, USA Abstract Complex infradiaphragmatic venovenous collaterals following Fontan palliation in the setting of inferior vena caval obstruction. Background: Venovenous collaterals (VVCs) are a known common late cause of cyanosis following Fontan palliation in patients with univentricular physiology. Infradiaphragmatic collaterals utilize the azygous systems, hepatic veins, and portal circulation. Although abdominal VVCs have been described following Kawashima procedure, the prevalence in course is less known in patient with intact inferior vena cava (IVC). We report a unique series of three patients with complex VVCs related to IVC obstruction and their subsequent management. Case Presentation: Three patients, status post Fontan procedure presented with cyanosis 5-15 years after the procedure. Their ages ranged between 10 and 19 years. The weight varied from 22 to 48 kg. Baseline saturations at the time of presentation were in the low to high 80 s. (1) Patient 1 had a large VVC from the right internal jugular vein (RIJV) to the left atrium fed by tributaries from the azygous vein formed by collaterals from the paravertebral plexus inferiorly. Due to severe RIJV stenosis, bilateral femoral venous occlusion, and difficult access to the collateral, he underwent hybrid procedure for closure of the VVC with a 14-mm Amplatzer vascular plug II (AVP II). (2) Patient 2 had severe stenosis of the IVC. This resulted in the formation of paravertebral venous collaterals that drained into the azygous vein and eventually into the right upper pulmonary vein. VVC was closed by deployment of two 14-mm AVP II devices in the azygous vein that was accessed through a paravertebral venous collateral followed by placement of seven stents in the IVC. (3) Patient 3 had complete obstruction of infrarenal IVC. The paravertebral venous collaterals coalesced and drained into the left upper pulmonary vein. Percutaneous closure of VVCs in these patients was complicated by infrarenal IVC obstruction and difficult access to the VVC. After considering the complexity of the procedure to eliminate the collateral, weighing the risks and benefits of closing the VVC, a decision was made not to intervene. The most recent follow-up of patients 1 and 2 were 11 and 1 months after the procedure. They reported a 10% increase in the baseline saturations and improved exercise tolerance. Discussion: VVCs may cause systemic arterial desaturation and exercise intolerance. In the presence of IVC obstruction or bilateral femoral venous obstruction, infradiaphragmatic VVCs are difficult to uncover. A high index of suspicion is needed in Fontan patients with late cyanosis to discover the presence of these collaterals by angiographic or radiographic evaluation of abdominal venous system. Interventional palliation of these collaterals can be complex. Moore, Howaida El-Said Rady Children's Hospital/UCSD, San Diego, USA Abstract Background: Intravascular ultrasound (IVUS) is a catheter-based imaging modality which generates cross-sectional views of vessel walls and lumens. This technique is utilized in adult interventional and vascular surgery frequently to assess extent of coronary artery disease and peripheral arterial disease and guide with management. IVUS has been described as superior to angiography in providing data about lesions of interest. The application of this tool to aid in interventional decision making for patients with congenital heart disease is scarce in the literature. Objective: The purpose of this study was to review our experience using IVUS as an adjunct tool to diagnose lesions and assess results of interventions upon vascular structures in pediatric patients during cardiac catheterization in conjunction with traditional angiography. Methods and Results: A retrospective chart review of all pediatric patients that underwent IVUS during cardiac catheterization to evaluate the cross-sectional lumen of non-coronary vessel(s) at Rady Children's Hospital from January 2018-December 2019 was performed. Mean patient age 1076 days ± 1182 days with mean weight 12.1 kg ± 9 kg. A total of 26 vessels were interrogated with IVUS. Pathology evaluated included pulmonary venous stenosis (n = 8), coarctation (n = 5), branch pulmonary artery stenosis (n = 6), systemic shunts and conduits (n = 3), and other peripheral vasculature (n = 4). IVUS added value in 100% of the cases in which it was utilized. Use of IVUS guided intervention in 88% of the procedures and defined the endpoint in 62% of the procedures. Conclusions: We found IVUS to be a safe tool for pediatric catheterization, with no complications during our study. IVUS was invaluable in enhancing our interpretation of identified pathology or in raising concern for occult lesions not seen on typical angiography. IVUS was particularly helpful in aiding with guiding interventional management and defining end point of interventions. Transcatheter Pulmonary Valve Implantation in Growing Children: Need for Reintervention and Effect on Valve Longevity Asimina Courelli 1 , Arpine Davtyan 2 , Bryan Mosher 2 , Peter Guyon 2 , Kanishka Ratnayaka 2 , Howaida El-Said 2 1 University of California, San Diego School of Medicine, San Diego, USA. 2 Division of Cardiology, Rady Children's Hospital, San Diego, USA Abstract Introduction: Transcatheter pulmonary valve implantation in pediatric patients \ 25 kg has been reported as a safe and effective procedure. However, limited investigation of treatment outcomes for these patients has been conducted. Since valve implantation is performed in growing patients, reintervention for somatic growth is expected. Therefore, we examined reintervention feasibility and resultant valve function. Methods: Patients having undergone transcatheter pulmonary valve implantation (Melody, Medtronic, Minneapolis, MN) with weight at implantation of less than 25 kg at Rady Children's Hospital in San Diego between January 2011 and December 2019 were identified. Patient profiles, short-term outcomes, and mid-term outcomes were reviewed. Results: Thirty-four patients were identified who had undergone Melody valve implantation. The mean age was 6.8 ± 1.7 yrs and the mean weight was 20.7 ± 2.9 kg. Most patients were initially diagnosed with Tetralogy of Fallot (n = 16), which had been surgically repaired. The right ventricular outflow tract (RVOT) substrate was either native RVOT (trans-annular patch) (n = 17), conduit (n = 14), or bioprosthetic valve (n = 3). The indication for the Melody valve implantation was either regurgitation only (RO, n = 19), stenosis only (SO, n = 5), or both regurgitation and stenosis (R ? S, n = 10). Implanted valve sizes were 22 mm (n = 14), 18 mm (n = 12), 20 mm (n = 6), 16 mm (n = 1), and 14 mm (n = 1). Immediately after implantation, no pulmonary regurgitation was noted on angiography or echocardiography for all patients and a significant decrease in RV-PA gradient (pre: 28 ± 7 mmHg, post: 15 ± 4 mmHg, p \ 0.01) was observed. 3/34 patients had a complications: vascular access (n = 1), RPA jailing (relieved during same procedure) (n = 1), and conduit pseudo-aneurysm that required placement of vascular plug (n = 1). 5/34 patients developed transient non-sustained ventricular ectopy, none of which resulted in hemodynamic instability. Three of those five patients were treated with Nadolol and all arrhythmias resolved within 3 months. To date, only 2/34 patients required reintervention. One required reintervention 2 years post implantation for stenosis due to interval growth, which was treated with angioplasty, and the other required reintervention 6 years post implantation for stenosis due to interval growth and Melody frame fracture, which was treated with re-stenting, and Melody valve placement. 2/34 experienced Type I stent fractures, only one of which required intervention. At the time of most recent follow-up, on average 2.5 years (range 6 ms-6.6 ys), none of the patients required surgical intervention or developed Melody valve endocarditis. Echocardiography showed an average maximum RVOT gradient of 17 ± 9 mmHg in RO patients and 11 ± 8 mmHg in R ? S patients with mild pulmonary regurgitation in only 3/34 patients. There was no patient mortality. Conclusion: Melody valves implanted in growing pediatric patients have maintained their functionality and the recipients experienced low incidence of endocarditis with a few requiring reintervention for interval growth without significant complications. The percutaneous technique is performed in the cardiac catheterization laboratory by transseptal puncture with a Brockenbrough needle followed by blade septostomy. Static balloon atrial septostomy is then performed with progressively larger balloons until satisfactory atrial communication is created. We describe a novel approach to left heart decompression by placement of a catheter in the left ventricle, and attaching the catheter to the venous limb of a centrifugal ECMO circuit to actively unload the left atrium and ventricle. The left atrium is further decompressed by the percutaneously positioned catheter stenting open the previously created atrial communication, thereby improving left-to-right atrial shunting. Methods: Three patients aged 8 months, 8 years, and 39 years (average 15.9 years), weighing 7.1, 20.2, and 65.8 kg (average 31 kg), developed severe left ventricular dysfunction and cardiopulmonary collapse requiring emergent placement on VA ECMO. Two patients developed respiratory failure and viral myocarditis-one from parainfluenza and one from influenza. The patient with influenza was converted from venovenous ECMO (VV ECMO) to VA ECMO due to acute biventricular decompensation. The third patient had congenital severe mitral regurgitation and undiagnosed left coronary artery ostial atresia, and arrested during diagnostic coronary angiography. After placement on VA-ECMO, all 3 patients developed left atrial hypertension based on echocardiographic and angiographic evidence of LV dysfunction and LA dilation. Transseptal puncture was performed with a Brockenbrough needle (Medtronic) followed by blade septostomy with Park Blade septostomy catheter (Cook Medical). Both procedures were performed with biplane fluoroscopy and transesophageal echo (TEE) guidance. Serial balloon dilation of the atrial communication with progressively larger balloons was performed. Pressure measurements in the LV, LA, and RA were then measured. TEE demonstrated suboptimal size of the atrial communication after the catheter was repositioned in the RA despite multiple blade and balloon atrioseptostomy procedures. The decision was then made to place a catheter with multiple side holes (pigtail catheter) across the atrial communication, into the LA, and then into the LV. The catheter was connected to the pre-pump venous limb of the centrifugal ECMO circuit. The catheter and venous sheath were then sutured in place. TEE confirmed proper catheter position. Conclusion: Biplane fluoroscopy and TEE-guided transseptal needle puncture followed by blade septostomy and serial static balloon septostomy are effective techniques employed in creating atrial communication to relieve left atrial hypertension in patients requiring VA ECMO. In some patients, solely creating an atrial communication may not be sufficient to relieve left atrial hypertension. We describe a technique of left heart decompression by additional placement of a catheter into the left ventricle and connection of this catheter to the venous centrifugal ECMO circuit. The drainage catheter efficiently unloads the left ventricle and stents the atrial communication open, increasing left-to-right atrial level shunting when needed and minimizing ongoing LV dilation. We studied 96 patients aged 70.6 (66.0; 73.0) years old, 32 (33.3%) were men, 64 (66.7%)-women. Grades 1-3 hypertension were present in 87 (91%), myocardial infarction-8 (8%), angina pectoris-23 (24%), PCI (6) (7%). Chronic heart failure Class I-II NYHA had 78 (81%). All included patients were statin-naïve. Computed tomography angiography of the coronary arteries (CTA CA) and estimation of Coronary Calcium Index (CCI) were performed on a dual-energy, 384-slice CT scanner of the premium class Siemens Somatom Force from General Electric Medical Systems (Germany). Standard biochemical blood test with determination of the lipid spectrum of blood, glucose, uric acid, determination of apolipoprotein A-1 (ApoA-1), and apolipoprotein B (ApoB) in blood serum was carried out by immunoturbidimetric method on a biochemical analyzer ''ARCHITECTPLUS: 4000,'' USA. Serum coenzyme Q levels were determined using the Human Coenzyme Q10 (CoQ10) Elisa kit reagent using an enzymatic method to determine the optical density at a wavelength of 450 nm (high-performance liquid chromatography). The results of a biochemical blood test are presented in Table 1 . Data of heart CT presented in Table 2 . We found positive moderate correlation between the levels of LDL and the CCI (r = 0.66, p \ 0.), between the levels of TC and the CCI (r = 0.52, p \ 0.), between the levels of LDL and CA significant stenosis (r = 0.29, p \ 0.05). CCI was higher in smokers (r = 0.33, p \ 0.), patients with diabetes mellitus (r = 0.30, p \ 0.), and in alcohol abusers (r = 0.57, p \ 0.r = 0.29, p \ 0.). Conclusion: Revealed high prevalence of clinical/subclinical manifestations of atherosclerosis in elderly people, which were interrelated Cardiac Catherization is an invaluable diagnostic and interventional tool in the management of patients with congenital and acquired heart disease. The CRISP Score is an essential pre-procedural risk scoring tool to stratify pediatric patients and identify those at risk for serious adverse events (SAE). We aim to internally validate this scoring tool at our institution in both our pediatric and adult patients with congenital heart disease. A total of 2031 procedures between January 2008 to December 2018 were reviewed retrospectively and the CRISP Score calculated based on pre-and intraprocedural data. Complications documented within the immediate 24 h post procedure were identified. A SAE was defined as any adverse event causing mortality, permanent morbidity, need for further interventions, or extended length of stay. Microsoft Excel and SPSS were then utilized to facilitate performance of basic measures of descriptive analysis and binary logistic regression. The cohort consisted of 1004 (49%) females and 1027 (51%) males with 66% being children (age \ 18 years) and 34% being adults ([ 18 years). Mean age for children was 7 years with a SD of 6.4 years, while for adults it was 30.3 years with a SD of 13.4 years. The age range for the cohort was 0-82.6 years. There were 29 SAE (1.43% of total procedures). Children accounted for 82.7% of the SAE. The rate of SAE in children was 1.79% (24/1342) and in adults was 0.73% (5/689). The rate of SAE in children increased as age of the child decreased with neonates (\ 1 month old) having a rate of SAE of 16.4% while children [ 5 years had a rate of \ 0.5%. The rate of SAE in pediatric patients gradually increased as the CRISP Risk Category increased. Risk Category 5 had a rate of SAE of 66.7% (4/6 procedures); risk category 4 of 12.2% (12/98); risk category 3 rate of 2.9% (8/278); and risk category 2 and 1 had no SAE. For every 1 unit increase in CRISP score in pediatric patients there was a statistically significant increased odds of having a SAE by 1.622 (SE 0.064; p value \ 0.001). In adults, patients in risk category 3 had a 5.3% rate of SAE (3/57); risk category 2 a rate of 0% (0/123); and risk category 1 a rate of 0.4% (2/509). For every 1 unit increase in crisp score in adult patients there was a statistically significant increased odds of having a SAE by 1.528 (SE 0.166 ; p value of 0.011). The CRISA scores were also calculated for the adult patients with a SAE and it was found to be more predictive in identifying adults likely to have a SAE than the CRISP. The mortality rate of this entire cohort of patients was 0.2% which accounted for 8.7% of all SAE (4/29). It should be noted that all deaths occurred in the pediatric age group with 3 of the 4 deaths being in neonates. Our results have internally validated the utility and accuracy of the CRISP Scoring System in predicting the risk of a SAE both in our pediatric and adult population which both showed that there was a statistically significant increase in the odds of having a SAE for every 1 unit increase in their CRISP Score. We conclude that CRISP Score should be used pre-procedurally and intraprocedurally to risk stratify patients with congenital heart disease undergoing cardiac catheterization. Objectives: To detail the pulmonary artery (PA) and MAPCA anatomy in a large group of infants, to assess relationships between anatomy and surgical outcomes, and to consider systems for classifying MAPCAs. Methods: All infants (age \ 1 year) undergoing a first cardiac surgery for TOF/MAPCAs from 2001 to 2019 at Stanford University were identified. Preoperative angiograms that delineated supply to all 18 pulmonary segments were reviewed to assess details of each MAPCA and the arborization and size of central PAs. Results: We studied 276 patients with 1068 MAPCAs and the following PA arborization patterns: 152 (55%) incompletely arborizing PAs, 48 (17%) normally arborizing PAs, 45 (16%) absent PAs, and 31 (11%) unilateral MAPCAs. There was extensive anatomic variability, but there was no difference in surgical outcomes according to PA arborization or the predominance of PAs or MAPCAs. Patents with lower total MAPCA and/or PA cross-sectional area were less likely to undergo complete repair. Conclusions: In TOF/MAPCAs, the distribution of MAPCAs is highly variable and essentially unique for each patient. Though each pulmonary segment can be supplied by a MAPCA, central PA, or both, in our analysis the type of supply was not associated with surgical outcome, and all anatomic combinations were conducive to a good repair. Of the variables we studied, total cross-sectional area of central PA and MAPCA material (TNPAI) was an important driver of outcome, with those having a paucity of total material being the most challenging patients to manage. Creatinine 1.2 mg/dl, and positive blood cultures for streptococcus pyogenes. Transesophageal echocardiogram image of a mixed, irregular, mobile echogenicity mass is observed, with multiple ramifications of approximately 10 9 9 mm on its short axis (Fig. 1) , concluding intra-aortic stent with image suggestive of thrombus (Fig. 2) . Angiotomography with 3D reconstruction aortic stent in ascending aorta with collapse in the proximal end (Fig. 3) and in sagittal slice image in relation to thrombosis of stent and collapse (Fig. 4) . Therefore, it was decided to undergo a surgical emergency treatment to remove a thrombosed stent and place a 10-cm polytetrafluoroethylene graft without complications, culture report of a positive surgical specimen for pyogenes streptococcus. Justification: To evaluate a rare complication of infected thrombus of the covered stents used for COA since there are no reported cases in Mexico. Discussion: The use of Advanta covered stent for treatment of aortic coarctation was first reported in 2009, stent is a balloon-expandable laser cut stainless steel open cell design encapsulated. Early reports have shown good short-term results with no acute complications. However, long term following data are not yet available. In this case, the mechanism of collapse of stent proximal was unclear also the complications are generally rare with a low percentage, in our case a collapse of the aortic stent at the proximal level is observed as a complication and what is most striking is the subsequent formation of thrombosis complicated with an infection. Conclusion: The use of stents for aortic coarctation has shown that it is safe, but in the long term it is important to identify its complications, in this case the formation of an infected thrombus secondary to a collapse of the stent is very rare is the only case reported in Mexico. Given that she was clinically stable and weighed only 1775 g, consensus opinion following our case management conference was to defer surgical repair until a minimum of 36 weeks of gestation to allow for improved maturation and weight gain prior to undergoing cardiopulmonary bypass. In the interim, however, she developed Klebsiella pneumoniae and worsening hypoxemia which did not respond to 100% FiO2. She became progressively hemodynamically unstable and suffered bradycardic arrest for which she was successfully resuscitated. Echocardiogram demonstrated a newly narrowed DV and new severe pulmonary hypertension (PH). Due to her critical status with guarded neurological prognosis, she was considered too high risk for surgical repair or palliation with ECMO. Therefore, she was emergently brought to the catheterization laboratory for DV stenting to relieve the obstruction. Using ultrasound guidance, transhepatic access was obtained in the portal vein with a 5/4 Merit sheath. Angiogram demonstrated a severely stenotic DV. The DV was crossed using a Maestro microcatheter through a 4 Fr JR 2.5 catheter over a 0.014 00 Choice PT wire, which was exchanged for an 0.018 00 Steelcore wire. A pre-mounted 4-mm 9 16-mm Formula 418 stent was advanced over the wire into the DV, where it was implanted with balloon inflation to 12 atm. Angiogram demonstrated excellent stent placement with vigorous flow into the hepatic venous system and the atria ( Figure 1 ). The balloon, wire, and sheath were removed. Coiling of the transhepatic tract was unsuccessful due to the short distance between liver capsule and the accessed portal vein, so manual compression was performed. Ultrasound demonstrated a small amount of blood in the abdomen, which remained stable on subsequent evaluation. The patient tolerated the procedure well with acutely improved oxygenation. Despite adequately decompressing the anomalous venous connection, however, her PH did not abate. Due to her small size and hemodynamic instability, her surgical candidacy did not improve. Her parents elected to withdraw life-sustaining measures. Conclusion: In neonates with obstructed infradiaphragmatic TAPVR, DV stenting may allow time for optimization of clinical status and improvement in surgical candidacy. Although DV intervention for this condition has been described via an indwelling umbilical venous catheter, this is the first report of the procedure via direct transhepatic access. We demonstrate that direct DV stenting is a viable method for short-term palliation in this condition. Early intervention may improve clinical outcomes and allow for relief of obstruction before PH develops. The mean final measured valve size on fluoroscopy was 20.9 mm (± 2 mm) in the Melody group and 24.5 mm (± 2.7 mm) in the SAPIEN group. Discharge and follow-up mean and peak Doppler gradients were similar between groups (Table) . The patients in the native RVOT group had significantly lower post-implantation gradients in both the Melody and SAPIEN groups (Table) . Only 1 patient in the entire cohort (SAPIEN in conduit) had [ mild pulmonary regurgitation at follow-up. Conclusion: In our cohort, post-procedure and short-term follow-up Doppler gradients were similar after Melody or SAPIEN TPVR. When groups were subdivided by RVOT type, lower post-procedure gradients were noted after TPVR into a native RVOT. Long-term follow-up is needed to further assess valve function over time. The incidence of endocarditis post-transcatheter pulmonary valve (TPV) implantation is variable (2.9-23%). We hypothesized that patients with native right ventricular outflow tracts (RVOT) may have a lower incidence of endocarditis compared to those with non-native RVOT (conduits and bioprosthetic valves). Methods: The institutional databases at Rady Children's Hospital (UCSD) and Mattel Children's Hospital (UCLA) were queried for patients receiving TPV over a ten-year period (2010-2020). The incidence of endocarditis for those with native versus non-native RVOT implantation was compared. Kaplan-Meier curves were constructed to compare freedom from endocarditis based on valve type with and without native RVOT. Results: There were 507 TPV, 113 of which had native RVOT and 394 of which had non-native RVOT. Out of these patients, 385 received Melody valves and 122 received Sapien valves. The incidence of endocarditis was 1.8% (n = 2) for native versus 9.4% (n = 37) for non-native. Of the two native RVOT patients that developed endocarditis, one received a Melody valve, and one received an Edwards Sapien 3 valve. All of the patients who developed endocarditis with non-native RVOT received a Melody valve. The Kaplan-Meier curves below display the incidence of endocarditis between the two RVOT substrates over time, factoring for valve type. There was male predominance in Group 1 (mBTS)-six (66%), in Group 2 (PDAS), equity of gender were observed. In Group 1 (mBTS), tricuspid atresia with severe pulmonary stenosis was the most common diagnosis with four patients (44.4%), followed by Tetralogy of Fallot (TOF) three (33.3%), and pulmonary atresia with ventricular septal defect and with intact ventricular septum (PA/IVS), with one patient each. In Group 2, the most common diagnosis was PA/IVS with three pts (37.5%), followed by tricuspid atresia with severe pulmonary stenosis-two pts (25%), TOF two pts (25%), and double outlet right ventricle with transposing of great arteries and severe pulmonary stenosis one pt. (12.5%). In comparing Group 1 (mBT) versus Group 2 (PDAS)-average ventilation time was 7.5 days vs 4.8 days, average of hospital stay was 22 vs 13 days. All patients (100%) in group 1 presented complications during hospitalization against 37. 5% in Group 2. The most common complication in both groups was sepsis: in Group 1 5 pts (55.5%) 9 2 pts (25%) in Group 2 (PDAS). Extubation laryngitis was seen in one pt. (12.5%) of Group 1. There was no deaths in group 2(PDAS) and there were three (33.3%) deaths in Group 1(mBTS Sinus rhythm and left bundle branch block were seen on the patient's ECG. The patient was conscious and cooperative in his neurological examination. He evaluated as right hemiplegic due to loss of strength in his right arm and dysarthric. Dilated cerebral sulcus secondary to diffuse atrophy and bilateral periventricular chronic ischemic gliotic changes were reported as pathological findings in brain CT. The patient was admitted to the neurology department with the diagnosis of acute ischemic cerebral vascular event. In laboratory tests, hemogram, renal, and liver function tests were normal. The patient's LDL value was measured as 172 mg/dl and HbA1C was measured as 6.4% mmol/mol. In echocardiographic evaluation, hypertrophy and impairment systolic function of the left ventricle were observed. Ejection fraction was measured as 35% by Simpson's method. Carotid vertebral doppler USG was performed for embolic focus etiology. Irregular fibrofatty-calcified plaque was observed extending from the left CCA bulbus level to the left ECA proximal segment. More than 90% stenosis was reported. In CT angiography, it was stated that this lesion did not cause significant stenosis. Carotid angiography was planned due to conflicting results between imaging methods. In the carotid angiography, thrombus image was detected in the left ICA proximal segment. Carotid endarterectomy was planned for the patient. After the successful endarterectomy operation he was discharged with medical therapy. PS: CT angiographic and carotid angiographic images of the patient are available if you request we can send. The Phantom Thrombus Filiz Ç elebi, Ocal Karabay Cardiology Specialist in Istanbul Marty Prof. Dr. Ilhan Varank Sancaktepe Research and Training Hospital, Istanbul, Turkey Abstract A 72-year-old male patient was admitted to the emergency department with a speech disorder and weakness on the right side. In his medical history, he did not have chronic drug use or additional disease except two package/year smoking. On physical examination, his blood pressure was 142/82 mmHg and his pulse was 72 bmp. Sinus rhythm and left bundle branch block were seen on the patient's ECG. The patient was conscious and cooperative in his neurological examination. He was evaluated as right hemiplegic due to loss of strength in his right arm and dysarthric. Dilated cerebral sulcus secondary to diffuse atrophy and bilateral periventricular chronic ischemic gliotic changes were reported as pathological findings in brain CT. The patient was admitted to the neurology department with the diagnosis of acute ischemic cerebral vascular event. In laboratory tests, hemogram, renal and liver function tests were normal. The patient's LDL value was measured as 172 mg/dl and HbA1C was measured as 6.4% mmol/mol. In echocardiographic evaluation, hypertrophy and impairment systolic function of the left ventricle. Ejection fraction was measured as 35% by Simpson's method. Carotid vertebral doppler USG was performed for embolic focus etiology. Irregular fibrofatty-calcified plaque was observed extending from the left CCA bulbus level to the left ECA proximal segment. More than 90% stenosis was reported. In CT angiography, it was stated that this lesion did not cause significant stenosis. Carotid angiography was planned due to conflicting results between imaging methods. In the carotid angiography, thrombus image was detected in the left ICA proximal segment. Carotid endarterectomy was planned for the patient. After the successful endarterectomy operation he was discharged with medical therapy. PS: CT angiographic and carotid angiographic images of the patients are available. If you request, we can send. 1 UC San Diego/Rady Children's Hospital, San Diego, USA. 2 UCLA, Los Angeles, USA. 3 Emory/Children's Healthcare Atlanta, Atlanta, USA. 4 UC San Diego School of Medicine, San Diego, USA. 5 Texas Children's Hospital, Houston, USA Abstract Background: There is growing concern regarding the incidence of infective endocarditis (IE) after placement of Melody Valves (MV). The percentage of patients with MV endocarditis requiring surgical removal and/or transcatheter intervention have been reported to be as high as 52% with mortality related to the valve in up to 8.7% of cases. We aimed to better characterize cases of MV endocarditis which could safely and adequately be treated with antibiotic therapy and not require surgical removal. Methods: All cases of endocarditis in patients with MV from four centers (Rady-UCSD, Mattel-UCLA, Children's Healthcare Atlanta/ Emory and Texas Children's Hospital) were reviewed. Cases that were successfully treated medically without reoccurrence and cases that necessitated surgical removal of the valve were compared in order to identify factors associated with successful medical treatment. Results: From 2010 to 2019, 666 Melody valves were implanted with total cumulative incidence of 63 cases of endocarditis in 61 patients (9%). Endocarditis was successfully treated medically in 33 (54%) of patients without reoccurrence during a mean duration of follow-up of 2.9 years (range 4.5 months to 9.5 years) after treatment. Two patients treated medically(6%) had reoccurrence of IE: one patient required removal of the valve with the second episode; the other patient was successfully treated without recurrence during follow-up of over 2 years. Infection with streptococcal species, no vegetations visualized on echocardiography and lower residual RVOT gradient at time of valve placement were associated with successful medical treatment. The most common reasons for valve removal were valve stenosis (28.6%), concern for inadequate response to antibiotics(persistent elevation of inflammatory markers, fevers, inability to clear blood cultures, etc.; 14.3%), valve stenosis with RV dysfunction (10.7%), and surgeon preference (7.1%). The proportion of cases of IE that were treated with surgical removal of the MV at each institution varied (27% vs. 42% vs. 55% vs. 64%). Conclusion: In a large multicenter study, MV IE managed with antibiotic therapy alone was successful in the majority of cases, with streptococcal IE, absence of vegetations on echocardiography, and lower residual MV gradient at time of valve placement bring predictive of successful antibiotic therapy. There was noticeable institutional variation in the proportion of cases of IE that were treated with surgical removal of the MV. (TCPC) has been shown to be feasible and safe for infants as small as 700 g or even smaller. However, the corrected gestational age of the infant may be a better representation of tissue maturity than the weight of the infant. Therefore, this study was aimed to explore the outcomes of TCPC based not just on weight, but also on the age of the infant. Methods: This was a retrospective study including all infants born at gestational age \ 28 weeks who underwent TCPC between Jan 2012 and May 2020 and weighed \ 3 kg at the time of the procedure. The study period was divided into four time blocks, Jan 2012 to Dec 2014, Jan 2015 to Dec 2017, Jan 2018 to July 2019, and Aug 2019 to May 2020. Success and complication rates were compared for those who underwent procedure at \ 28 days to those infants that underwent TCPC [ 28 days of age. Results: During the study period, TCPC was attempted on 241 infants that satisfied the inclusion criteria, with 99.1% success rate. There was no difference in success rates based on the age at TCPC (99.3% vs. 99% for procedural age \ 28 days vs. [ 28 days, respectively; P = 0.82). Overall, 140 infants underwent TCPC at \ 28 days of age, 29 of whom were \ 14 days, and 54 infants underwent TCPC between 15 and 21 days of age. The median age at TCPC progressively decreased from 60 days of life (14-211 days) between January 2012 and December 2014 to 18 days (8-38 days) between August 2019 and May 2020 (P \ 0.00001). Similarly, the weight at TCPC decreased over the same time periods (median 1985 g vs. 900 g; P \ 0.00001). Procedure-related complication rates were similar for those \ 28 days vs. [ 28 days of age at the time of TCPC (2.8% vs. 4.9% respectively; P = 0.42). Conclusions: It is feasible and safe to perform TCPC after the first week of life for infants born \ 28 weeks' gestation. As experience grows, more infants are referred earlier after birth which translates to performing TCPC on smaller infants. Benefits of early TCPC have to be determined in order for this therapy to be advocated routinely for all premature infants (Table 1) Recently, the Amplatzer Piccolo Occluder (APO) was approved for PDA closure for infants weighing [ 700 g. The feasibility and safety of the procedure for anyone below this weight cut-off has not been previously explored. The aim of the study is to describe the feasibility and safety transcatheter closure of patent ductus arteriosus (PDA) in premature infants who weigh \ 700 g at the time of the procedure. Methods: This is a retrospective, single-center, study to explore the outcomes of transcatheter PDA occlusions performed on infants weighing \ 700 g. Results: A total of 18 patients weighing between 540 and 670 g (mean = 612.8 g) were identified to have underwent the procedure between the two centers. The gestational age ranged between 22 and 26 weeks (median 24 weeks), and average birth weight was 537.5 g. The mean age at the time of PDA closure was 20 days (range 8-35 days). The implant success rate was 100%. The devices used included the MVP-5Q (N = 8), the 3-2 APO (N = 5), and the 4-2 APO (N = 5). The procedure time was 26 ± 23 min and fluoroscopy time was 3.7 ± 3.1 min. One patient, weighing 640 g required chest compressions for resuscitation following the procedure, but recovered and since then has grown normally to hospital discharge. There were no other procedural complications. However, anomalous drainage of the right superior vena cava into the left atrium is extremely rare, and few cases has been reported in the literature. Cyanosis, heart failure, and brain abscess are the most common forms of clinical presentation. Case Report: Ten-years-old girl, previously healthy, with a history of short breathless and cyanosis for 2 years ago after an episode of brain abscess. Upon physical examination, with a resting oxygen saturation of 88% in room air, with light digital clubbing, and mild cyanosis. A 2D transthoracic echocardiogram showed a positive microbubble test, with a large amount of saline contrast into the left chambers, despite the interatrial septum appear to be intact. Subsequently, the patient underwent to a CT for further investigation, which showed a possible drainage of the right superior vena cava into the left atrium and a patent foramen ovale (PFO). She was then referred for a cardiac catheterization for better evaluation and surgical plan. The diagnosis of the superior vena cava (SVC) draining into the left atrium was confirmed, in addition an anomalous drainage of the right upper pulmonary vein into the SVC was seen. The patient was then sent for surgery. At the surgery the distal portion of the right SVC with the right upper pulmonary vein was left in place and the remaining portion was then anastomosed to the right atrium. The PFO was closed. Her postoperative period was uneventful, with the oxygen saturation of 98% in room air. She was discharged on oral anticoagulation and has been followed up on the outpatient clinic. Conclusion: Anomalous drainage of the superior vena cava in the left atrium is extremely rare, as the lesion causes an obliged right-to-left shunt, surgical repair is necessary. It can be isolated or associated to anomalous pulmonary venous drainage and interatrial communication. Cyanosis, heart failure, and brain abscess should draw attention for the possibility of this diagnosis. Abstract Introduction: The persistence of the fifth arch arteries is extremely rare. The bilateral fifth arch arteries have never been documented, unilateral partial fifth arch artery has been demonstrated only once in a developing human embryo, dorsal collateral channels connecting the fourth and sixth arches are common, to qualify as the fifth arch artery any channel must arise from the ascending aorta proximal to the brachiocephalic artery, take a serpentine course and lie extrapericardially and terminate in the dorsal aorta, or through the sixth arch into pulmonary artery or arteries. The use of echocardiography for diagnosis alone is difficult, with percutaneous angiography (or both) considered as reference methods. However, cardiac computed tomography and magnetic resonance imaging can more accurately outline the anatomy of the arch and its variation. Case report: Male neonate 12 days old, born in another service, term, first child, mother with non-insulin-dependent gestational diabetes, presented with choking and cyanosis on the first day of life, being referred to a neonatal intensive care unit, where, after hearing a heart murmur, he performed echocardiography and was diagnosed with tricuspid atresia and pulmonary valve stenosis. Maintained with prostaglandin and referred for evaluation by pediatrics cardiology and therapeutic procedure. The echocardiogram confirmed tricuspid atresia, pulmonary valve stenosis, and aortic arch to the right. Cardiac catheterization has been programed for stent placement in the ductus arteriosus. During examination, previous diagnoses were confirmed and anomalous origin of the vessels in the base was observed. There was a right subclavian with usual origin and other vessels originating from a common trunk (5th arch) that emitted the right and left carotid arteries, left subclavian, and tortuous artery canal (Figure 1 ). Through a puncture through the left axillary artery (Figure 2) , two coronary stents were positioned, the first Nexgen 3.5 9 19 mm in the distal segment, and the second Nexgen 4.0 9 13 mm in the proximal segment of the canal, in overlapping nails with the first. Procedure performed successfully and without complications (Figure 3) . The patient evolved with 89% saturation, discharge from the ICU on the 2nd postoperative day, and referred for outpatient follow-up using anti-aggregation. Conclusion: The presence of the 5th arch artery is rare and when associated with other complex heart diseases, it needs the evaluation of physicians specialized in congenital heart diseases for the proper diagnosis and treatment. Rush University, Chicago, USA. 2 Rainbow Babies and Children's Hospital, Cleveland, USA Abstract Introduction: Transcatheter (TC) closure of atrial septal defects (ASD) has become the gold standard modality in adults. However, small size and defective aortic rims in children make TC technically challenging and surgical closure (SC) might be preferred. The possibility of device erosion led to a 2012 FDA panel review for use of the Amplatzer Septal Occluder device that might have limited its use. We sought to investigate the trends of ASD closure using both modalities and its effect on healthcare utilization in the United States. Methodology: We analyzed the National Inpatient Sample and Kid Inpatient Database from 2003 to 2016. Two cohorts, TC and SC, were created and compared to study the outcomes and temporal trends in healthcare usage in children (\ 20 years) with ostium secundum ASD. Patients with complex congenital heart disease, other congenital anomalies, and genetic disorders were excluded. Results: A decreasing trend in the use of TC for ASD was noted with a noticeable drop in TC-ASD since 2011-2012 ( Figure 1 ). SC was more common in the younger cohort (1-4 years), males and Caucasians (all p \ 0.001)- Table 1 . While hemopericardium, infective endocarditis, and ventricular arrhythmias were significantly more common in SC (all, p \ 0.001), arterial thrombus, stroke, device embolization (all, p \ 0.001), and severe sepsis (p = 0.01) were significantly more common in TC. No significant differences were noted in cardiac tamponade, complete heart block, cardiac arrest, sepsis, and death between the groups. Among procedures, blood transfusion, cardiopulmonary resuscitation (both p \ 0.001), and pacemaker insertion (p = 0.013) were significantly associated with SC with no significant difference noted in ECMO use between the groups (Table 2 ). Mean length of stay (LOS) and mean hospitalization charges (HC) are significantly higher in the SC group (3.93 ± 0.04 vs 1.87 ± 0.06 and 90,421 ± 835 vs 62728 ± 1200, both p \ 0.001). Mean inflationadjusted HC and LOS show an overall uptrend in both groups during the study period ( Figure 2 ). Overall trends in surgical and transcatheter closure of ASD during the study period Trends of mean length of stay and related hospitalization charges over the study period Baseline demographics of two groups-transcatheter and surgical closure of ASD Conclusion: There is a notable overall national trend favoring SC-ASD in children causing an impact on increasing healthcare resource use. Further studies are needed to study practice variations that are prevalent due to uncertainty in choosing between the two modalities of treatment to better help improve outcomes in ASD. Hospital Especialidades Jose Carrasco Arteaga, Cuenca, Ecuador Abstract Three-month-old female infant, who was admitted for 40-degree fever of 10 days of evolution, in poor general irritability, with 5 days of diarrheal stools, was treated with antipyretic and antimicrobial with no improvement on the two recent days vomiting, irritability, rejection of the oral route, with a punctate rash, erythematosus, in the chest, upper limbs as well as dry cough, dehydration, for which reason he entered the pediatric acute respiratory care unit in isolation at the risk of infection by SARCOV-2 due to suspicion. Upon admission to the hospital, the patient had leukocytosis, anemia, decreased platelets and altered liver enzymes. During her hospitalization with fever of 40 degrees of difficult handling, systematic desaturation of 50-60%. in paraclinics with elevated Ferritin 569, low hemoglobin 5.7 g, platelets 70,000, elevation of dimer D: 2.3. Chest thorax with apical right infiltrate, light cardiomegaly. Heart echocardiogram without congenital anatomical malformations, light pericardial effusion, mitral regurgitation, and light tricuspid, LVEF 65% Simpson, TAPSE 12 mm, PSAP 25 mmHg, both right dilated coronaries with rosary image measuring 2.5 mm in origin and 5 9 aneurysm 7 mm diameter. Left coronary artery with an 8-mm-diameter aneurysm. EKG sinus rhythm without data on ischemia or arrhythmia, Troponin I 0.001. Immunoglobulin was started at 2 g/kg/dose to pass in 24 to 36 h, aspirin 80 mg/kg/day, continued with antibiotic. Infant Febrile persists, 2 peaks of 38 and 39.2 C despite 72 h of antibiotic and immunoglobulin dose. It was decided to administer a second bolus of immunoglobulin at 2 g/kg/dose, continue ASA and clopidogrel, and Methylprednisolone bolus of 30 mg/kg for 3 days. Without improvement with persistent fever, a second dose of immunoglobulin was administered. With good response to the afebrile patient treatment, without data of respiratory distress, tolerates the oral route, is adequately fed. An angiotomography was performed, showing giant aneurysmal lesions in both coronaries, aneurysms in the left subclavian artery, mammary arteries, and a large aneurysm in the abdominal aorta. At discharge, the patient was on enoxaparin 5 mg every 12 h, aspirin 5 mg/kg/day, Clopidogrel 0.2 mg/kg/day, prednisone, and weekly methotrexate. Conclusion: From the studies of Dr Yamasaki in Mexico in 2012 and 2018, it was established that in some patients they can develop toxic shock due to kawsaki disease, however, due to the presence of covid-19, in children with negative pcr but with a positive or igg test for covid-19, develop a very aggressive presentation that can lead to involvement of large-caliber arteries such as the abdominal aorta. The genomic profile is pending. as necrotizing enterocolitis due to systemic hypoperfusion. Recently, catheter-based PDA closure has emerged as an appealing alternative to invasive surgical ligation in preterm infants; however, evidence to support this procedure in infancy, particularly in the premature population, is still evolving. Methods: A retrospective chart review was conducted to collect information regarding demographics, neonatal and maternal clinical characteristics, and procedural and post-catheterization data. Inclusion criteria included infants born at \ 32 weeks of gestational age whose PDAs were closed via catheterization at our institution between January 2017 and August 2019. Infants with critical congenital heart disease and/or lethal congenital anomalies were excluded from this study. Results: Twenty-seven patients were included in our study. Indications for PDA closure in our patient population included hemodynamically significant PDA on echocardiogram, difficulty weaning respiratory support, poor feeding and weight gain, and development of NEC. Median gestational age and weight were 26 3-7 weeks and 820 g (ranging from 23 3-7 to 30 weeks and 400 to 1540 g, respectively). Most infants tolerated the procedure well and without serious adverse outcomes. One infant developed an intimal flap post catheterization that resolved without invasive intervention, and 1 infant developed a PAH crisis after PDA closure with resolution of PAH prior to discharge. Statistically significant associations were found between PDA plug closures and decreased oxygen requirements, decreased pulmonary artery hypertension, decreased diuretic requirements, and decreased vasodilator requirements by time of discharge. Conclusions: Successful device closures of PDAs are feasible and safe, and preliminary findings show promising outcomes without mortality or long-term morbidity following transcatheter PDA closure. Right Ventricular Outflow Tract Stenting in Symptomatic Infants Without the Use of a Long Delivery Sheath Niall Linnane, Mohamed Nasef, Colin J McMahon, Orla Franklin, Terence Prendiville, Mark Walsh, Adam James, Paul Oslizlok, Kevin P Walsh, Damien Kenny Children's Health Ireland Crumlin, Dublin, Ireland Abstract Introduction: Right ventricular outflow tract (RVOT) stenting has been shown to improve pulmonary artery blood flow and pulmonary artery growth in symptomatic infants with tetralogy of Fallot, prior to complete repair. The stent is typically delivered to the RVOT using a long delivery sheath. The aim of this study was to describe the safety and efficacy of RVOT stenting without the use of a long delivery sheath. Methods: Retrospective data analysis of patients under 1-year old undergoing RVOT stenting from January 2010 to January 2020 at a single tertiary pediatric cardiology center. Patient demographics and follow-up data are provided. Data are presented as medians with range in parentheses. Results: Sixty-seven RVOT stents were deployed during 56 procedures into 47 patients (tetralogy of Fallot (n = 25), atrioventricular septal defects and tetralogy of fallot (n = 8), double outlet right ventricle (n = 5), and other conditions with right ventricular outflow tract obstruction (n = 9). The median age and weight at insertion were 41 days (range 2-204) and 3.67 kg (range 1.59-7.1), respectively. Thirty-one procedures were semi-elective and 25 were emergencies. Stent positioning was confirmed with transthoracic echocardiogram and/or RV angiography across the VSD from an aortic approach. The median total procedure and fluoroscopy times were 67.5 (range 15-145) and 19 min (1-107), respectively. The median radiation dose was 136cGY/cm 2 (range 5-2002). Thirty-five patients were either admitted in ICU pre-procedure or required ICU admission post procedure with a median ICU length of stay of 3 days (range 1-48). The median length of stay was 8 days (range 1-258). There were 3 major complications and 2 minor complications. There were two deaths (included in the 3 major complications) within 30 days of the procedure. A patient with Cornelia de Lange Syndrome (1.8 kg) died following stent embolization and inability to wean from emergency cardiopulmonary bypass for stent retrieval and the second infant had an unexplained asystole arrest post procedure while awaiting transfer to ICU. Conclusion: RVOT stenting has become commonplace for treating severe RVOTO in small symptomatic infants in the setting of a VSD. In this series, we demonstrate that the procedure is technically possible with minimal complications without the use of a long sheath. Manama, Bahrain. 4 Texas Heart Institute, Houston, USA. 5 Cincinnati Children Hospital, Cincinnati, USA Abstract Patent Ductus Arteriosus (PDA) stenting has evolved as a valid alternative to surgical systemic-pulmonary shunts in patients with duct-dependent pulmonary circulation facilitating improved saturations and pulmonary artery growth. This may be more compelling for neonates B 2.5 kg, in whom surgical palliation may be challenging. The objective of this study is to evaluate outcomes following PDA stenting in patients B 2.5 kg from three large tertiary centers. Methods: Retrospective review of all neonates B 2.5 kg with ductdependent pulmonary circulation who underwent stenting from three tertiary referral centers. Procedural details, pulmonary arterial growth, reinterventions, surgery type, and outcome were assessed. Results: Forty-two PDA stents were implanted in a total of 31 patients (16 female) at median age of 8 days (IQR 5-15) and median weight of 2.1 kg (IQR 2-2.4 kg). Thirteen patients (41%) had femoral artery access, 8 patients (25%) had carotid artery access, and the remaining had axillary or umbilical cord artery access. Two patients developed femoral artery thrombosis, while one patient developed right carotid artery aneurysm, and another had intracranial thrombosis. Twenty-one patients (68%) had tortuosity indices of II or III. Oxygen saturations improved from median of 73% (IQR 62.5-79.5) to 88% (IQR 80-93%, p \ 0.001). Two patients proceeded to emergency surgical shunts and one patient underwent a surgical shunt 74 days post PDA stenting. The median ICU stay was 3.5 days (IQR 2-6 days) and the median hospital stay was 25 days . Twenty patients (65%) required reintervention with either balloon dilation or re-stenting at a median age of 86.5 days ). At 6-month follow-up, the median z-score for the left and right pulmonary artery diameters increased from -1.1 (IQR -1.71 to -0.2) to -0.7 (IQR -1.27 to 0.1) (p 0.35) and -1.31 (IQR -1.8 to -0.6) to -0.09 (IQR -1.2 to 0.33) (p 0.05), respectively. There was one procedure-related death and 4 interstage mortalities not directly related to the PDA stent. Conclusions: PDA stenting in infants B 2.5 kg is safe and effective, promoting pulmonary artery growth and improving oxygen saturations. Reintervention rates are relatively high. Children Health Ireland, Dublin, Ireland. 2 Heart center of Memphis, Memphis, USA Abstract Background: Transcatheter occlusion of the patent ductus arteriosus (PDA) in low and very low birth weight infants has become more commonplace, however, to date, there is only one FDA-approved PDA device for this group of patients, and it is not suitable for arterial ducts [ 4 mm in diameter. We report a two-center experience using the 7Q Medtronic Micro Vascular Plug (MVP) to close large PDA's in infants \ 2.5 kg. Methods: Retrospective review of departmental databases and medical charts to define patient cohort and collect demographic, procedural, and follow-up data. Results: Twenty-two patients (12 male) with a median gestational age of 25.5 weeks (IQR 24-28) and median birth weight of 800 g (572-1075) underwent attempted PDA occlusion with 7Q MVP using exclusive transvenous approach. The median age and weight at time of PDA occlusion were 32 days (IQR 24-28) and 1100 g (IQR 960-1700), respectively. The median PDA length was 12 mm (IQR 11-12.65). The median aortic and pulmonary end of the PDA diameter were 5.1 mm (IQR 4.9-5.5) and 4.8 mm (IQR 4.6-5.3), respectively. Successful device occlusion was achieved in 95% of cases. There was one failed attempt as the arterial duct diameter was too large and therefore the device was removed. All except one patient had no residual shunt as demonstrated by the intraprocedural TTE. There were no procedural complications and no patients had increased Doppler velocities at either the left pulmonary artery or descending aorta post procedure. Conclusions: The 7 Q MVP is safe and effective for providing transcatheter closure of large ([ 4 mm) hemodynamically significant PDA'S in infants less than 2.5 kg. The lack of retention disk provides favorable device characteristics in avoiding impingement on surrounding structures. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Pediatr Cardiol Clinical Utility of Cardiac MRI for Prediction of Balloon-Expandable Percutaneous Pulmonary Valve Implantation in Patients with a Non-Conduit Right Ventricular Outflow Tract 4-51.2) years prior to attempted PPVI. Indication for PPVI included pulmonary regurgitation (n = 26) and mixed RVOT disease containing stenosis and regurgitation (n = 7). PPVI was successful in 24 patients using the available BE TPVs implanted at the following diameters: 20 mm (n = 1); unsuccessful secondary to large RVOT size (n = 3), coronary/aortic root compression (n = 4), and inability to technically implant the valve (n = 2). There was moderate correlation between the RVOT diameter by cMRI of 23.4 ± 4.6 mm (mean ± standard deviation) compared to the balloon-sizing waist of 23.5 ± 2.3 mm, with a Spearman's correlation coefficient of 0.53. Based on cMRI data, the imaging team predicted 24/24 (100%) of successful BE PPVI. The imaging team predicted 4/9 (44%) unsuccessful procedures which included the three patients with a RVOT too large for BE PPVI. Conclusions: There is moderate correlation between the dynamic RVOT by cMRI and balloon-sizing as it pertains to BE PPVI. A dedicated PPVI team can help predict successful implantation using cMRI data Melody Endocarditis Does Not Equal Valve Removal: Variations in Practice in a Multicenter Experience Median (range) Catherine E. Tomasulo, Yoav Dori, Madhumitha Saravanan, Christopher L. Smith The Children's Hospital of Philadelphia, Philadelphia, USA Abstract Background: Intramesenteric (IM) dynamic contrast magnetic resonance lymphangiography (DCMRL) is a novel imaging modality that allows for visualization of mesenteric/intestinal lymphatic drainage. This imaging technique can be used to identify lymphatic flow abnormalities that may not be seen with intranodal (IN) or intrahepatic (IH) DCMRL, especially in patients with protein-losing enteropathy (PLE) and ascites. These findings are essential in planning future interventions, particularly in patients with congenital heart disease (CHD) and high central venous pressure when considering thoracic duct embolization versus selective lymphatic duct embolization and/or thoracic duct decompression. Methods: This is a single-center, retrospective review including all patients with CHD who underwent IM-DCMRL from 5/2019 to 3/2020. Results: Twenty-five patients with CHD underwent IM/IH/IN-DCMRL at median age 12.3 years (range 0.2-37.1 years) and median weight 30 kg (range 3.4-111.4 kg). Twenty patients had single ventricle heart disease: 18 s/p Fontan, one s/p Glenn, and one s/p heart transplantation. The remaining five patients had transposition of the great arteries s/p arterial switch operation, pulmonary atresia s/p biventricular repair, total anomalous venous return s/p repair, coarctation of the aorta s/p repair with dysplastic mitral valve, and pulmonary stenosis s/p pulmonary valvotomy. 17/25 patients had a prior diagnosis of PLE. 16/17 had duodenal perfusion or intralumenal leak identified with both IH and IM-DCMRL. One patient had no abnormal duodenal perfusion with IM, but distal duodenal perfusion with IH-DCMRL. 11/16 patients had leak into the proximal duodenum with both injections and five had perfusion or leak into the distal duodenum with IM-DCMRL and leak into the proximal duodenum with IH-DCMRL. Seven of the remaining eight patients without a clinical PLE diagnosis had no abnormal leak from IM or IH-DCMRL. However, one patient showed a duodenal leak only with IH-DCMRL. The ability of IM-DCMRL and IH-DCMRL to identify duodenal perfusion and intraluminal leaks correlating with clinical PLE was statistically significant (p \ 0.001). No patient had duodenal leak/perfusion identified with IN-DCMRL.17/25 patients were also noted to have ascites. DCMRL imaging identified a peritoneal leak in 12/17; one with only IM-DCMRL, three with only IH-DCMRL, and eight with both. Two patients without prior ascites had peritoneal leaks identified; one only with IH-DCMRL and another with IN-DCMRL, IH-DCMRL, and IM-DCMRL. The ability of IM-DCMRL and IH-DCMRL to identify peritoneal leaks in patients with ascites was statistically significant (p \ 0.05).There were no procedural complications or mortality. Twelve patients underwent subsequent selective glue embolization of abnormal hepatoduodenal/periduodenal lymphatic networks identified and two underwent glue embolization of lymphatic networks leaking into the peritoneum. Conclusion: IM-DCMRL is an effective imaging modality for evaluating mesenteric lymphatics and can help identify abnormalities in lymphatic flow not seen on other imaging, particularly in patients with PLE or ascites. This information can help with the planning of future procedures for patients with CHD. Ernesto Mejia, Emily C. Kish, Martin L. Bocks, John S. Lozier UH Rainbow Babies and Children's Hospital, Cleveland, USA Abstract Introduction: Covered stents are often needed during congenital cardiac catheterization to treat high-grade stenoses or to repair/exclude areas of injured vasculature following angioplasty or bare-metal stenting. Several small diameter covered stents are commercially available and have been used off-label in children. The ability to postdilate a stented vessel to eventual adult diameters to keep pace with somatic growth is critical following initial stent placement in children. The ability to post-dilate a covered stent is potentially more limited by its PTFE covering. This study aimed to compare in vitro performance characteristics of two brands of covered stents with serial post-dilation and fracture. Methods: Seven iCast stents (Atrium Medical Corporation, Hudson, NH) and eight Viabhan VBX stents (W. L. Gore & Associates, Inc., Newark, DE) of various sizes were measured before expansion using a Keyence digital microscope (Keyence Corporation of America, Ithaca, IL). The stents were then expanded with their pre-mounted balloons, followed by measurements of stent diameter and length both with the balloon inflated and deflated. Subsequent serial dilation's were performed using non-compliant balloons (Conquest or Atlas [Bard Peripheral Vascular, Inc, Tempe, AZ]) at 2-mm-diameter intervals ranging from 6 to 22 mm, with additional measurements made after each expansion. Balloon diameter and pressure were recorded at stent fracture, PTFE tear, and 'napkin-ring' formation. Results: The VBX stents fractured in a predictable manner. Stent fracture of the 5-mm and 6-mm diameter VBX stents occurred during dilation with the 10-mm balloon (100% and 67% oversized, respectively); the 7-mm VBX stents fractured on the 14-mm balloon (100% oversized); and the largest VBX stents fractured on the 20-or 22-mm balloon (* 180% oversized). In comparison, all of the iCast stents fractured during dilation with the 14-or 16-mm balloons, and had less predictable fracture patterns (range 75-220% oversizing). The PTFE of the VBX stents tore only with stent fracture or later. All of the iCast stents experienced partial or complete PTFE tear prior to stent fracture, however, these stents were studied after their expiration dates. Both stents had similar recoil between 5.5 and 5.8%. The VBX stents experienced significantly more foreshortening and achieved a 'napkin-ring' configuration more readily than the iCast stents. Conclusion: Compared to Atrium iCast stents, Gore Viabhan VBX endovascular stents had more foreshortening and similar recoil during serial post-dilations. VBX stents fractured at predictable post-dilation diameters based on their nominal diameter. The VBX stents readily developed a 'napkin-ring' configuration, and their PTFE tore after stent fracture in all cases. The iCast stents fractured at 14 or 16 mm diameter, irrespective of original diameter, and all experienced PTFE tear prior to stent fracture. These in vitro performance characteristics should be considered when selecting covered stents in small children with congenital heart defects and when considering post-dilation at the time of implantation or during a catheterization procedure performed in the future.