key: cord-0749376-w02w80do authors: Yano, Taka-aki; Kajisa, Taira; Ono, Masayuki; Miyasaka, Yoshiya; Hasegawa, Yuichi; Saito, Atsushi; Otsuka, Kunihiro; Sakane, Ayuko; Sasaki, Takuya; Yasutomo, Koji; Hamajima, Rina; Kanai, Yuta; Kobayashi, Takeshi; Matsuura, Yoshiharu; Itonaga, Makoto; Yasui, Takeshi title: Ultrasensitive detection of SARS-CoV-2 nucleocapsid protein using large gold nanoparticle-enhanced surface plasmon resonance date: 2022-01-20 journal: Sci Rep DOI: 10.1038/s41598-022-05036-x sha: 234a346217b6eee7976de792dce4d3f34a061b85 doc_id: 749376 cord_uid: w02w80do The COVID-19 pandemic has created urgent demand for rapid detection of the SARS-CoV-2 coronavirus. Herein, we report highly sensitive detection of SARS-CoV-2 nucleocapsid protein (N protein) using nanoparticle-enhanced surface plasmon resonance (SPR) techniques. A crucial plasmonic role in significantly enhancing the limit of detection (LOD) is revealed for exceptionally large gold nanoparticles (AuNPs) with diameters of hundreds of nm. SPR enhanced by these large nanoparticles lowered the LOD of SARS-CoV-2 N protein to 85 fM, resulting in the highest SPR detection sensitivity ever obtained for SARS-CoV-2 N protein. . They combined the LSPR technique with a thermoplasmonic effect to achieve a sub-pM detection limit. Basso et al. succeeded in SPR detection of SARS-CoV-2 antibodies in serum from COVID-19-positive patients using Au SPR chips conjugated with functional self-assembled monolayers 11 . The effectiveness of SPR techniques notwithstanding, practitioners continue to demand improvements in SPR sensor limits of detection (LODs). A key breakthrough in the endeavor to transcend current LODs is the incorporation of AuNPs onto Au SPR chips 12 . AuNPs used in SPR sensors are usually conjugated with secondary antibodies in SPR measurements, thereby providing enhanced antigen-antibody binding affinity, analogous to that provided by a sandwich ELISA 13 . Furthermore, a strongly enhanced electromagnetic field is generated at the gap between AuNPs and the Au chip substrate due to the electromagnetic coupling between the LSPR in the AuNPs and the SPR on the planar Au chip substrate. The plasmonic coupling causes an SPR dip angle perturbation, which leads to significantly improved SPR sensitivity. Highly sensitive detections of a variety of biomedical analytes (proteins, aptamers, DNAs, RNAs, etc.) have already been demonstrated using nanoparticle-enhanced SPR [14] [15] [16] [17] . Herein, we demonstrate nanoparticle-enhanced SPR sensing of SARS-CoV-2 N protein at fM levels using exceptionally large AuNPs with diameters of 150 nm, as schematically shown in Fig. 1a . The large AuNPs are found to exhibit SARS-CoV-2 detection sensitivity a full order of magnitude higher than the commonly-utilized smaller (tens of nanometers in diameter) AuNPs commonly utilized in nanoparticle-enhanced SPR. The crucial plasmonic roles of the large AuNPs in significant sensitivity enhancement are elucidated both experimentally and theoretically. Large nanoparticle-enhanced SPR is demonstrated to be more effective for large bioanalytes such as N protein. Our SPR system was based on angular interrogation in the Kretschmann configuration with an Au film thickness of 50 nm and an excitation wavelength of 650 nm as detailed in Fig. S1 . As AuNPs are expected to enhance SPR detection sensitivity, we first evaluated the dependence of the SPR angular shift (∆θ on AuNP concentration using avidin-conjugated AuNPs with a mean diameter of 40 nm. A HEPES buffer blank was initially incubated with a bare Au chip substrate for reference, and then ∆θ was measured in situ as the concentration of AuNP was increased stepwise every 10 min by replacing the AuNP-containing buffer solution. Figure 1b represents the value of ∆θ plotted as a function of AuNP concentration up to 100 pM. There are two linear regions observed in the plot with a larger slope in the very low-concentration region below 10 pM, as shown in the inset of Fig. 1b . To evaluate the diameter dependence of the angular shift, we also measured ∆θ for AuNPs of a variety of diameters (60 nm, 80 nm, and 150 nm) in the low-concentration over which the linear relationship was observed. Taking the number of injected AuNPs into account, the amount of ∆θ induced by a single nanoparticle was estimated for each diameter. As shown in Fig. 1c , the single particle-induced ∆θ was found to increase significantly with increasing nanoparticle diameter. Figure 1d shows scanning electron microscope (SEM) images of AuNPs of 60 nm and 150 nm diameters remaining on the gold-coated chip substrates after the SPR measurements. Considering the numbers of injected AuNPs, the adsorption ratio of AuNPs on the chip substrates was estimated to be approximately 6%. The AuNP surface density at 10 pM shown in Fig. 1b , as deduced from the adsorption ratio, was 2.26 × 10 8 particle/cm 2 . The nanoparticle density was thus approximately one order of magnitude lower than those previously reported 18, 19 , validating the use of AuNPs at low-concentration. It should be noted that while high concentrations of AuNPs degrade the Q factor of the SPR curve, the low-concentration of AuNPs did not, as shown in Supplementary Fig. S2 . The SPR dip angle can therefore be determined more accurately at low AuNP concentrations; this constitutes an additional advantage of using low AuNPs concentrations. Inspired by the large nanoparticle-enhanced shift in ∆θ, we demonstrated highly sensitive detection of antigens using AuNPs of 150 nm diameter. Prostate-specific antigen (PSA) was utilized for this demonstration, since the size of PSA (34 kDa) is comparable to that of SARS-CoV-2 N protein (49.1 kDa). Initially, SPR detection of PSA antigens (3 nM) was performed using an anti-PSA antibody (1H12)-coated Au chip with the neither use of secondary antigens or AuNPs. Figure 2a shows the shift in the SPR angle (∆θ) measured as the PSA concentration changed from 0.3 nM (100 ng/ml) to 24 nM (800 ng/ml). The figure clearly exhibits a linear increase with increasing PSA concentration, resulting in a LOD of 2.78 nM. Figure 2b shows an SPR sensorgram obtained as the 3 nM PSA solution was first incubated for 60 min and incubated for a further 60 min with secondary anti-PSA antibody (5A6) at a concentration of 0.4 µg/ml. Although ∆θ reached a plateau 60 min after injection of PSA solution, additional injection of the secondary antibodies induced a significant increase in ∆θ owing to enhanced antigen-antibody affinity. As summarized in Fig. 2c , the sandwich assay using the secondary antibodies provided an angular interrogation shift 3.7 times as large. Finally, an AuNP-based sandwich assay was performed using secondary antibody-conjugated AuNPs. After incubation with PSA solution for 30 min, an AuNP solution with an optical density of 0.5 was injected, and the SPR angular shift was measured 60 min after the injection. Figure 2d shows the SPR angular shifts for AuNPs of 40 nm and 150 nm diameters, measured as functions of PSA concentration. Both AuNP sizes exhibited linear increases in SPR angular shift with increasing PSA concentration. Significantly, the AuNPs of 150 nm diameter provided a ∆θ value one full order of magnitude larger than that of the AuNPs of 40 nm diameter. Notably, the AuNPs of 150 nm diameter enhanced the angular shift by a factor of 120 even though the PSA concentration was ten times lower than that used in the AuNP-free SPR measurements in Fig. 2a . This angular shift enhancement resulted in an overall detection sensitivity enhancement by a factor of 1200. To investigate the plasmonic roles of the large AuNPs in the higher detection sensitivities of the antigens, we simulated the SPR curves for AuNPs of 40 nm and 150 nm diameters using finite element analysis (COMSOL Multiphysics 5.6). Figure 3a shows a simulation model in which AuNPs with diameters of 40 nm or 150 nm were placed on a 50 nm-thick Au film with a gap distance of 30 nm corresponding to the thickness of the antibody-antigen-antibody sandwich. The angle-resolved SPR spectra in Fig. 3b were obtained by calculating the reflection of the p-polarized incident light (λ: 650 nm) over a range of incident angles. The AuNP concentration was set to 0.69 particles per square micrometer. Compared with the AuNP-free case, the AuNPs of 40 nm diameter produced a 0.06 degree increase in the SPR angle, whereas AuNPs of 150 nm diameter produced a 0.94 degree increase. This finding indicates significant enhancement of SPR sensitivity by AuNPs of 150 nm diameter. Figure 3c shows SPR angular shifts plotted as functions of AuNP concentration for AuNP diameters of 40 nm and 150 nm. For AuNPs of 40 nm diameter, the angle shift increased almost linearly with increasing AuNP concentration. On the other hand, for AuNPs of 150 nm diameter, the shift was not linearly proportional to the concentration, but at low concentrations (< 0.07 particle/µm 2 ), a linear increase in angular shift was obtained with increasing AuNP concentration. For AuNPs of 150 nm diameter, the slope at low concentrations was 1.5 degree/ particle, which is 16 times higher than for AuNPs of 40 nm diameter. Therefore, AuNPs of 150 nm diameter provided detection sensitivity more than one order of magnitude higher than AuNPs of 40 nm diameter in SPR measurement; this finding is in good agreement with the experimental data in Fig. 2d . This behavior is caused by efficient excitation of the gap-mode plasmon between AuNPs of 150 nm diameters and the Au thin film, significantly affecting the SPR signal. For the relatively large gap distance (~ 30 nm), AuNPs of 150 nm diameter are superior to those of 40 nm diameter in terms of both field enhancement and confinement. As the diameter of AuNPs increases, the resonant wavelength of the gap mode plasmon gets closer to the excitation wavelength (650 nm), resulting in the higher near-field intensity at the large gap for AuNPs of 150 nm as shown in Fig. 3d . Furthermore, in terms of field confinement for the large gap distance, AuNPs of 40 nm diameter confined incident light within a closer vicinity of the particle surface than AuNPs of 150 nm diameter, making it less efficient for the confined field to couple with the gold thin film at the large gap distance. Figure 3e Finally, the large gold nanoparticle-enhanced SPR was applied in the detection of SARS-CoV-2 N protein. Figure 4a shows a sensorgram that simultaneously recorded the whole detection process for each of three concentrations of N protein in a 3-well chamber. After baseline measurement with phosphate-buffered saline (PBS) buffer solution, 10 µg/mL of an anti-N protein antibody (B3451M) was introduced, followed by incubation for 30 min (Fig. 4a, solid line I) . The SPR chip was then rinsed and incubated in PBS-T (PBS containing 0.05% Tween20; blocking buffer) for 30 min (Fig. 4a, solid line II) . Immediately after rinsing with N protein-diluted buffer, N protein-diluted buffer solutions of three different concentrations (0 pM, 21.7 pM, and 217.4 pM) were simultaneously added to each well of the sample chamber, followed by incubation for 30 min (Fig. 4a , solid line III). After washing of the chip substrate in PBS-T (Fig. 4a, solid line IV) , 150 nm AuNPs conjugated with secondary antibodies of biotinylated anti-N protein (B3449M) in PBS-T including 0.1% casein were added, followed by incubation for 1 h (Fig. 4a, solid line V) . Finally, after washing of the substrate with PBS-T, the SPR dip angles for three concentrations were simultaneously monitored (Fig. 4a , solid line VI). As shown in the enlarged view of Fig. 4a , the SPR angles were sensitive to the N protein concentration, increasing with the addition of N protein. Furthermore, SPR measurements for lower N protein concentrations were also performed in the same manner, as summarized in Fig. 4b . The SPR angular shift ∆θ showed its highest sensitivity to N protein concentration at concentrations below 20 pM. Figure 4c shows an enlarged view of Fig. 4b , depicting the linear slope in the low-concentration region. Considering the angular detection limit (0.0022 degree) and its coefficient of variation (10%), the LOD is estimated to be 85 fM (4 pg/ml), resulting in the highest SPR detection sensitivity ever obtained for SARS-CoV-2 N protein. www.nature.com/scientificreports/ In conclusion, highly sensitive detection of SARS-CoV-2 N protein by SPR in a sandwich configuration was demonstrated using exceptionally large AuNPs of 150 nm diameter. AuNPs of 150 nm diameters were found to efficiently induce the gap-mode plasmon between the AuNPs and the Au chip substrate, leading to a tenfold enhancement of the SPR angular shift compared with AuNPs of 40 nm diameters. Furthermore, a lowconcentration of AuNPs (< 10 pM) was probed and found to be effective in suppressing degradation of the Q factor in the SPR curves; this suppression contributed to highly accurate determination of the SPR angle. The large nanoparticle-enhanced SPR sensors via the use of the large AuNPs with diameters of hundreds of nm is a promising technique for sensing a variety of bioanalytes with sizes of several tens of nm. Although the LOD (85 fM; 4 pg/ml) of N protein achieved by our SPR-based technique is comparable to analytical sensitivity of typical RT-PCR testing (LOD: ~ 30 copies/ml; 4.5 pg/ml), the SPR technique does not suffer from long time for sample preparation in comparison with RT-PCR, enabling to absolutely reduce the turnaround time for sample-to-result. The SPR-based system is constructed by assembling simple optical components with an inexpensive camera and LED light source, making the diagnostic device available at a price of < $10,000. Furthermore, the SPR-based technique does not require to educate technicians for diagnosis while PCR-based diagnosis needs to train technicians for extraction of RNA from patient specimens, which accelerates practical implementation. Owing to the highly-sensitive, cost-effective and easy-to-handle capabilities, the novel SPR-based technique is a promising alternative to currently available diagnostic tools, and would have a great potential to not only detect but also identify SARS-CoV-2 variants if it is combined with plasmon-enhanced vibrational spectroscopies. Reagents and chemicals. All the chemicals and reagents used were of analytical grade. The SARS-CoV-2 N protein antibodies used were mouse monoclonal antibodies purchased from Meridian Life Science (B3451M and B3449M). Prostate-specific antigen (PSA) and anti-PSA antibodies (5A6 and 1H12) were purchased from HyTest. Au nanoparticles with diameters of 40, 60, 80, and 150 nm were purchased from Sigma-Aldrich (753637, 753653, 753661, and 746649, respectively). Blocking reagent (Blocker Casein in PBS 37582) was purchased from Thermo Fisher Scientific. Neutralized avidin from egg white was purchased from FUJI-FILM Wako Pure Chemical Corp. Multichannel surface plasmon resonance system. The SPR system used was developed by modifying a customizable SPR unit (Kyushu Keisokki Co., Ltd., Japan). As schematically shown in Supplementary Fig. S1a , it was based on angular interrogation in the Kretschmann configuration consisting of a hemicylindrical glass prism in contact with a gold-coated glass slide (10 mm × 10 mm). For biohazard protection, a disposable polystyrene cuvette was employed for analyte injection and was immobilized on the gold-coated glass slide using a compressive latch. The plastic cuvette possessed three wells with each maximum injection volume of 70 µl, providing parallel SPR measurements of three samples of different concentrations. In each measurement, 50 µl of analyte was injected into each well. The entire SPR system was mounted inside a thermally insulating box. The www.nature.com/scientificreports/ temperature inside the box was maintained at 25 °C or 37 °C by means of Peltier elements in order to suppress thermally induced drift of the SPR curves. As for the optical configuration, the p-polarized component of an LED light with wavelength 650 nm was incident to the prism with angular convergence generated by a cylindrical lens. The reflected light with angular diffusion was captured by a CMOS camera through relay lenses, enabling the camera to detect the reflected light with incident angles ranging from 65° to 73° with angular resolution of 0.00001°. With the use of custommade software, user-selected regions of interest were defined for each well on the camera image, providing the angle-resolved SPR curve for each well. The SPR angle for each well was determined from the dip position with minimum intensity in the SPR curve and was monitored in real time. All the solutions used were preheated to the working temperature of 25 °C or 37 °C. In all experiments, the shift in SPR angle (∆θ was determined from the change in the SPR angle averaged over a period from 1 min before to 1 min after analyte injection. Immunoassays. There were three types of immunoassays demonstrated in this study, as illustrated in Supplementary Fig. S1b . One (Fig. S1b (i) ) was a non-labeling immunoassay in which injected antigens were captured by monoclonal antibodies immobilized on the gold-coated substrate. The other two immunoassays were sandwich assays with the use of labeled secondary antibodies. In one case (Fig. S1b (ii) ), biotinylated secondary antibodies were injected into the medium and incubated with antigens. In the other case (Fig. S1b (iii) ), avidinconjugated Au nanoparticles were further injected along with the biotinylated secondary antibodies. The biotinylated antibodies were likely to be assembled to avidin-coated Au nanoparticles due to the high affinity between biotin and avidin. The antibody-conjugated Au nanoparticles were finally bound to the antibody-immobilized Au surface together with antigens as a sandwich. Recombinant protein purification. Sf9 cells were infected with AcBac/His-SARS-CoV-2-N(Sf) virus and harvested at 72 h post-infection. Cells were lysed in lysis buffer (20 mM Tris-HCl pH 8, 135 mM NaCl, 1% Triton, 10% Glycerol) and incubated on ice for 5 min. The cell lysates were then sonicated for five rounds of sonication cycles of 30 s ON and 30 s OFF at HIGH power setting using a Bioruptor II. The insoluble material was removed by centrifugation at 7,000 rpm for 15 min at 4 °C. The solubilized extract was then incubated with cOmplete His-Tag Purification Resin (Roche) for 16 h at 4 °C with rotation. The resin was harvested by centrifugation at 7,000 rpm for 3 min at 4 °C and washed five times with wash buffer (20 mM Tris-HCl pH 8, 135 mM NaCl, 1% Triton, 10 mM Imidazole). His-N protein was then eluted five times with elution buffer (20 mM Tris-HCl pH 8, 135 mM NaCl, 1% Triton, 250 mM Imidazole). The purified His-N protein was subjected to SDS-PAGE, followed by Coomassie Brilliant Blue (CBB) staining. As indicated by the arrowhead in Supplementary Fig. S3 , the 49.1 kDa protein was detected as His-N protein. The full-length image of the gel is presented in Supplementary Fig. S4 . The concentration of purified His-N protein was 600 µg/ml. Progress of the COVID-19 vaccine effort: viruses, vaccines and variants versus efficacy, effectiveness and escape Assay techniques and test development for COVID-19 diagnosis COVID-19 antibody tests and their limitations Evaluation of current diagnostic methods for COVID-19 Sensitivity of chest CT for COVID-19: comparison to RT-PCR Positive RT-PCR test results in patients recovered from COVID-19 A novel rapid detection for SARS-CoV-2 spike 1 antigens using human angiotensin converting enzyme 2 (ACE2) SARS-CoV-2 coronavirus nucleocapsid antigen-detecting half-strip lateral flow assay toward the development of point of care tests using commercially available reagents A comprehensive review on plasmonic-based biosensors used in viral diagnostics Dual-functional plasmonic photothermal biosensors for highly accurate severe acute respiratory syndrome coronavirus 2 detection Fast and reliable detection of SARS-CoV-2 antibodies based on surface plasmon resonance Surface plasmon resonance: Signal amplification using colloidal gold nanoparticles for enhanced sensitivity Antibody-gold nanoparticle bioconjugates for biosensors: synthesis, characterization and selected applications Directed self-assembly of gold binding polypeptide-protein A fusion proteins for development of gold nanoparticle-based SPR immunosensors Au-NPs enhanced SPR biosensor based on hairpin DNA without the effect of nonspecific adsorption Aptamer-Au NPs conjugates-enhanced SPR sensing for the ultrasensitive sandwich immunoassay Ultrasensitive detection of testosterone using conjugate linker technology in a nanoparticle-enhanced surface plasmon resonance biosensor Investigation of plasmonic signal enhancement based on long range surface plasmon resonance with gold nanoparticle tags Surface plasmon resonance of Au colloid-modified Au films: Particle size dependence This research was supported by Japan Agency for Medical Research and Development (AMED) with grant number of 20he0822006j00. This work was also supported in part by JST Moonshot R&D Grant Number JPMJMS2025 (K. Y. and A.S.). We thank Hiroya Kirimura, Masaya Okada, Yuki Seki and Koki Hoshikawa of Sysmex Corp. for preparing and supplying diluted buffer solutions. We also thank Katsue Horikoshi and Tatsuya Kawakami of JVCKENWOOD for technical assistance. We also acknowledge the financial support for the project from the Promotion of Regional Industries and Universities by the Cabinet Office, as well as from the Plan for Industry Promotion and Young People's Job Creation by the Creation and Application of Next-Generation Photonics by Tokushima Prefecture. The authors declare no competing interests. The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-022-05036-x.Correspondence and requests for materials should be addressed to T.Y. or T.Y.Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.