key: cord-0748748-w8f9fvfg authors: Lai, Meng Yee; Suppiah, Jeyanthi; Thayan, Ravindran; Ismail, Ilyiana; Mustapa, Nur Izati; Soh, Tuan Suhaila Tuan; Hassan, Afifah Haji; Peariasamy, Kalaiarasu M.; Lee, Yee Leng; Lau, Yee Ling title: RNA purification-free detection of SARS-CoV-2 using reverse transcription loop-mediated isothermal amplification (RT-LAMP) date: 2022-01-04 journal: Trop Med Health DOI: 10.1186/s41182-021-00396-y sha: 16040662229b662babce3b3017baaae9828bf3f2 doc_id: 748748 cord_uid: w8f9fvfg BACKGROUND: Current diagnosis of SARS-CoV-2 infection relies on RNA purification prior to amplification. Typical extraction methods limit the processing speed and turnaround time for SARS-CoV-2 diagnostic testing. METHODS: Here, we applied reverse transcription loop-mediated isothermal amplification directly onto human clinical swabs samples to amplify the RNA from SARS-CoV-2 swab samples after processing with chelating resin. RESULTS: By testing our method on 64 samples, we managed to develop an RT-LAMP assay with 95.9% sensitivity (95% CI 86 to 99.5%) and 100% specificity (95% CI 78.2–100%). CONCLUSION: The entire process including sample processing can be completed in approximately 50 min. This method has promising potential to be applied as a fast, simple and inexpensive diagnostic tool for the detection of SARS-CoV-2. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s41182-021-00396-y. SARS-CoV-2 has caused a global COVID-19 pandemic disease. The number of reported COVID-19 cases worldwide has passed 180 million and deaths more than 4 million. To date, real time reverse transcription polymerase chain reaction (rRT-PCR) remains the gold standard for diagnosis. However, the turnaround time is long, requires sophisticated equipment and expensive probes which are not affordable in poor resource settings. There are several on-going efforts to minimize the PCR process and recent developments using loop-mediated isothermal amplification may offer a solution. The LAMP assay is highly specific as it involves 4 to 6 primers (forward inner primer, forward outer primer, reverse inner primer, and reverse outer primer) [1] . In addition, its short amplification time allows LAMP to be potentially developed as a point-of-care diagnostic tool. In the current study, RNA was extracted by chelating resin and without further purification, the extracted RNA directly served as the template in RT-LAMP. Chelex-100 chelating resin has been used in DNA extraction from dried blood spots [2] , mosquito [3] , forensic materials [4] , and plant materials [5, 6] . However, there are not many reports on RNA extraction using chelating resin. In this study, we demonstrated a simple RNA extraction from swab samples using chelating resin. Tropical Medicine and Health We used 49 rRT-PCR positive and 25 rRT-PCR negative nasopharyngeal and oropharyngeal swabs samples. The rRT-PCR threshold cycle value (C T -value) of these samples ranged from 13.95 to 38.85 (Additional file 1: Table S1 ). The swab samples which were collected in sterile vials containing viral transport medium (VTM) were preheated for 1 h at 65 °C. An aliquot of 250 μL of the swab samples were sent to laboratory in dry ice and used for evaluation of RT-LAMP assay. Ethical approvals were obtained from UMMC Medical Ethics Committee (202041-8418) and Medical Research Ethics Committee (MREC) Ministry of Health Malaysia (NMRR-20-2344-56994). Total RNA extracted using chelating resin was according to the procedures described by Flynn et al. [7] with minor modification. A 30% Chelex-100 resin solution (BioRad Laboratories, US) was prepared in RNase-free water. The solution was mixed by 3 min vortex and kept in 4 °C until further use. A total of 15 μL of VTM was added to 22.5 μL of a 30% Chelex-100 resin solution, mixed by pipette up and down for 5 s, incubated at 95 °C, 10 min, cooled on ice for 2 min, followed by 30 s short spin. The supernatant was readily served as the template for amplification. The RT-LAMP assay was performed in a total of 25 μL reaction mixture consisting of 11 µL RNase free water, 2.5 µL of 10 × isothermal amplification buffer II, 1. Analytical sensitivity and specificity tests of N1 gene had been tested and reported previously [8] . In this study, the clinical sensitivity and specificity of RT-LAMP were evaluated using 74 samples. Sensitivity was calculated based on the formula: (number of true positives)/(number of true positives + number of false negatives) and specificity was calculated as (number of true negatives)/(number of true negatives + number of false positives). Based on our previous published report, analytical sensitivity and specificity tests for N1 gene were 1 copy/µL RNA sensitive and 100% specific, respectively [8] . Out of 49 rRT-PCR positive samples, RT-LAMP detected 47 samples as positive and did not detect any of the rRT-PCR negative samples as positive. It was 95.9% sensitive (95% CI 86.0 to 99.5%) and 100% specific (95% CI 78.2-100%). Results showed that RT-LAMP did not detect two patients with low viral load (rRT-PCR C T value of 35.19 and 36.06). The RNA in these samples maybe degraded during storage or shipping. There is correlation between C T values of rRT-PCR and detection time of RT-LAMP. Figure 1 shows samples with high C T value took a longer time to amplify by RT-LAMP. According to Spearman's rho test, there is strong correlation between C T values of rRT-PCR and detection time of RT-LAMP. Both are statistically significant, rho = 0.79, p < 0.001. When C T values of rRT-PCR increase, detection time of RT-LAMP also become longer. Nucleic acid extraction using chelating resin offers many advantages compared to conventional methods, such as spin/vacuum columns-based or paramagnetic beads-based extraction kits. These typical column-and paramagnetic beads-based methods are tedious as it involves multiple steps of processing and requires various consumables. A major drawback of these methods is the requirement of large quantities of biological samples for extraction [6] . However, using chelating resin for RNA extraction, only a minute volume of VTM samples (15 μL) was needed and the preparation of chelating resin was simple. The simple RNA preparation step improved diagnostic efficiency, cost and time. In addition, another benefit of using chelating resin for extraction was demonstrated by Walsh et al. [4] during their DNA extraction from forensic materials. They reported that DNA extraction from semen and blood stain samples using chelating resin was as sensitive if not more sensitive than proteinase K and phenol-chloroform extraction methods. Coupled with the chelating resin extraction method, we achieved a promising result of 95.9% sensitivity for RT-LAMP. Flynn et al. [7] obtained 90% sensitivity during their optimization of RT-LAMP-based SARS-CoV-2 diagnostic protocol for saliva samples. Another study from Howson et al. [9] showed that overall sensitivity of direct RT-LAMP on saliva samples was approximately 83%. Intriguingly, we managed to detect 10 samples with high C T values (rRT-PCR C T > 33.68-38.85) (Additional file 1: Table S1) in the current direct swab-to-RT-LAMP assay. This is a promising finding compared to other direct swab-to-RT-LAMP studies. Without further RNA extraction from nasopharyngeal swab samples, Lamb et al. [10] managed to detect 40% (N = 4/10) of SARS-CoV-2 (rRT-PCR C T < 24) samples by RT-LAMP. In another study by Wei et al. [11] , out of 13 clinical swab positive samples (rRT-PCR C T < 31) tested, they only managed to detect 5 samples by RT-LAMP assay. Various simplified preparation methods have been reported which can circumvent RNA extraction procedures due to the shortage of commercial kits in expanding diagnostic facilities of SARS-CoV-2. Fowler et al. [12] managed to obtain 67% sensitivity of RT-LAMP using VTM sample (1:20 dilution in water). Nie et al. [13] reported a direct RT-LAMP by heating nasopharyngeal swab samples at 95 °C for 30 s and cooling on ice for 2 min. In addition, Dao Thi et al. [14] managed to obtain 86% sensitivity RT-LAMP using swab samples either without any treatment or after heat treatment for 5 min at 95 °C during their development of colorimetric RT-LAMP assay. As for the high sensitivity of direct RT-LAMP, Yoshikawa et al. [15] also reported 1.43 × 10 3 copies of RNA by direct heating the swab samples at 95 °C for 10 min. However, we were not able to replicate these methods after several trials. The failure may be due to the presence of inhibitors, such as glucose in VTM. Apart from real time turbidity detection of RT-LAMP results, the results can also be examined by observing the colour changes of the end product. We included HNB colorimetric dye in the LAMP assay during the preparation of the master mix. Carryover contamination can be eliminated as the dye was not added into the reaction RT-LAMP (mins) CorrelaƟon between C T value of rRT-PCR and detecƟon Ɵme of RT-LAMP) Spearman's rho test, rho=0.79, p<0.001 Even though SARS-CoV-2 antigen-detection tests that offer results in 15 min and as they become more widely available as at-home, self-administered and over-thecounter tests at pharmacy stores, our RT-LAMP assay still can be considered as an alternative for SARS-CoV-2 testing especially in resource limited areas. Most of these tests show lower sensitivity as compared to our previous published RT-LAMP assay (100% sensitivity) [16] . Meanwhile, Harmon et al. [17] reported 78.9% sensitivity using an at-home direct antigen rapid test kit. Another study reported by Shrestha et al. (2020) also revealed that low sensitivity of lateral flow antigen test kits for COVID-19 testing with 85% sensitivity [18] . Moreover, the developed RT-LAMP here costs only USD$1.95/reaction as compared to antigen detection test (USD$4.30). We have successfully developed an optimized direct swab-to-RT-LAMP assay without RNA purification. This method is sufficiently sensitive in detecting SARS-CoV-2 directly from clinical nasopharyngeal swab samples in VTM. Given these results and coupled with RT-LAMP assay, this methodology can facilitate the expansion of SARS-CoV-2 diagnostic testing especially in resource limited areas. Loop-mediated isothermal amplification of DNA Comparative performance of PCR using DNA extracted from dried blood spots and whole blood samples for malaria diagnosis: a meta-analysis. Sci Rep A LAMP assay for the rapid and robust assessment of Wolbachia infection in Aedes aegypti under field and laboratory conditions Chelex 100 as a medium for simple extraction of DNA for PCR-based typing from forensic material Rapid and simple method for DNA extraction from plant and algal species suitable for PCR amplification using a chelating resin Chelex 100 Method for improving the quality of genomic DNA obtained from minute quantities of tissue and blood samples using Chelex 100 resin A simple direct RT-LAMP SARS-CoV-2 saliva diagnostic. medRxiv preprint Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of SARS-CoV-2 Preliminary optimisation of simplified sample preparation method to permit direct detection of SARS-CoV-2 within saliva samples using reversetranscription loop-mediated isothermal amplification (RT-LAMP) Rapid detection of novel coronavirus/Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) by reverse transcription-loop mediated isothermal amplification Direct diagnostic testing of SARS-CoV-2 without the need for prior RNA extraction A highly effective reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay for the rapid detection of SARS-CoV-2 infection Evaluation of a direct reverse transcription loop-mediated isothermal amplification method without RNA extraction for the detection of human Enterovirus 71 subgenotype C4 in nasopharyngeal swab specimens A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples Development and evaluation of a rapid and simple diagnostic assay for COVID-19 based on loop-mediated isothermal amplification A sensitive reverse transcription-loop mediated isothermal amplification assay for direct visual detection of severe acute respiratory syndrome coronavirus 2 infection Validation of an at-home direct antigen rapid test for COVID-19 Sensitivity and specificity of lateral flow antigen test kits for COVID-19 in asymptomatic population of quarantine centre of Province 3 Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations We acknowledge support of NIH Biodefense and Emerging Infections Research Resources Repository, NIAID, NIH for providing the following reagents; gamma-irradiated SARS-coronavirus, NR-9547. We would like to thank the Director General of Health Malaysia for his permission to publish this article. The online version contains supplementary material available at https:// doi. org/ 10. 1186/ s41182-021-00396-y.Additional file 1. Table S1 . Result of rRT-PCR (CT -value) and RT-LAMP (mins).Authors' contributions MYL: study design, data analysis and interpretation, and writing original draft. JS: sample collection. RT: sample collection. II: sample collection. NIM: sample collection TSTS: sample collection. AHH: sample collection. KMP: sample collection. YLL: sample collection. YLL: supervision, study design, data interpretation. All authors read and approved the final manuscript. This study was supported by Prototype Research Grant Scheme (PRGS), PR001-2020B (PRGS/2/2020/SKK09/UM/02/1) from the Ministry of Education, Malaysia. The data set for this study is available from the corresponding author and Hospital Sungai Buloh on a reasonable request. Data without names and identifiers will be made available after approval from the corresponding author and Hospital Sungai Buloh.