key: cord-0748550-0y5kniv0 authors: Kim, Soo Min; Kim, Jinmyeong; Noh, Seungwoo; Sohn, Hiesang; Lee, Taek title: Recent Development of Aptasensor for Influenza Virus Detection date: 2020-11-16 journal: Biochip J DOI: 10.1007/s13206-020-4401-2 sha: 9904c0a861f5cfe8e039d61d34f7c34e15b71652 doc_id: 748550 cord_uid: 0y5kniv0 In nowadays, we have entered the new era of pandemics and the significance of virus detection deeply impacts human society. Viruses with genetic mutations are reported nearly every year, and people have prepared tools to detect the virus and vaccines to ensure proper treatments. Influenza virus (IV) is one of the most harmful viruses reporting various mutations, sub-types, and rapid infection speed for humans and animals including swine and poultry. Moreover, IV infection presents several harmful symptoms including cough, fever, diarrhea, chills, even causing death. To reduce the IV-induced harm, its proper and rapid detection is highly required. Conventional techniques were used against various IV sub-types including H1N1, H3N2, and H5N1. However, some of the techniques are time-consuming, expensive, or labor-intensive for detecting IV. Recently, the nucleic acid-based aptamer has gained attention as a novel bioprobe for constructing a biosensor. In this review, the authors discuss the recent progress in aptasensors for detecting IV in terms of an electrochemical and an optical biosensor. Globalization leads to economic growth in intercontinental commerce. People typically believe that glo-balization simultaneously provided prosperity to develop as well as developing countries. Human interactions between countries bring about explosive growth in the tourism industry that boosts the economic growth of many countries. However, though globalization brings about economic growth, it also leads to new rises in various infectious diseases and pathogenic viral agents like severe acute respiratory syndrome coronavirus (SARS-CoV) 1,2 , Middle East respiratory syndrome coronavirus (MERS-CoV) 3 , coronavirus disease 2019 (COVID-19) 4,5 , Zika virus 6.7 , and others [8] [9] [10] . Among them, influenza virus (IV) is extremely important in that it usually infects the host, causing the "flu" and presents with several symptoms including cough, high fever, diarrhea, and sore throat 11, 12 . IV undergoes several mutations and easily infects humans, swine, birds, and bats almost every year [13] [14] [15] . Each different infected species of a host can infect other specie hosts, enabling human-to-animal spread and vice versa. Phylogenetically, IV is classified as a single-stranded negative-sense RNA, and can be divided into four types including influenza A (IAV), B (IBV), C (ICV), and D (IDV) 16, 17 . The virus can be classified into highly pathogenic influenza (HPI) and low pathogenic influenza (LPI) based on the infectious ability. Among them, influenza A virus is highly infectious and causes economic, health, and ethnic problems. Influenza A viruses genetically encode for several proteins such as polymerase, hemagglutinin (HA), nucleoprotein, neuraminidase (NA), membrane proteins, and non-structural proteins. Especially, the envelope proteins, HA and NA, can be used to determine the influenza A virus subtype 18 . HA is an antigenic glycoprotein found on the surface of the IV that help the binding of IV to sialic acid residues on the surface of the epithelial cells of organisms. So far, sixteen types of HA proteins have reported in the IAV, IBV, ICV and IDV. NA found on the surface of IV that mediated the virus binding to the cell to be released from the host cell. NA acted as the cleavage of sialic acid groups from glycoproteins. And, nine types of NA proteins have reported in the IAV, IBV, ICV and IDV. Among them, eight types of IV HA proteins (H1, H2, H3, H5, H6, H7, H9, and H10) can infect humans and cause several pandemics 19, 20 . For example, the outbreak of IV H1N1 resulted in the Spanish flu in 1918 that had between 50 and 100 million victims 21 . In 1968, IAV H3N2 infected 500,000 victims in the Hong Kong area 22 . More recently, the 2009 swine flu pandemic was cause by H1N1, and around 400,000 people were victimized 23 . Moreover, avian influenza H5N1 can also infect people, making thousands of victims and economic damage in many countries 24 . Conventionally, there are two types of methods have been used to detect IV. Immunosensors like the enzyme-linked immunosorbent assay (ELISA) and genetic biosensor including the reverse transcriptase polymerase chain reaction (RT-PCR) method were widely used [25] [26] [27] [28] . The antibody-based ELISA technique provided high accuracy and generality. Based on antigen-antibody recognition, the ELISA technique is regarded as a general detection tool for IAV surface antigen detection 29 . However, it required large amounts of expensive antibodies, a long detection time, and a well-trained researcher. In the case of RT-PCR, this technique provides more sensitivity and selectivity compared to ELISA, and it can determine the genetic information. However, the PCR-based method requires an extra purification step and expensive analytical devices for detecting IV 27, 29, 30 . Today, aptamer-based detection methods have been suggested to overcome these current problems including expensive antibody production cost, ethnical problem, fast manufacturing cost 31, 32 . The aptamer is composed of several nucleic acid or peptide sequences that can bind with high affinity to specific targets like proteins, small molecules, chemicals, and nucleic acids 33 . These non-canonical nucleic acids and peptides have been applied to therapeutic agents in pharmaceutical science 34 and detection elements for various biosensors 35 . The early stage of aptamer research was reported by Tuerk, Gold, Ellington, and Szostak through in vitro systematic evolution of ligands by exponential enrichment (SELEX) 36 . Consequently, several meth-ods were developed to obtain RNA or DNA aptamers 37 . Recently, the cell-based in vivo selection method 38 and graphene-based selection method 39 were reported. When the target binds to the aptamer, the 3D ligand structure between target and aptamer flexibly changes to form a thermodynamically stable structure 40 . Aptamers have been studied since 1980 to find several aptamers for understanding the binding mechanism at a molecular level, treating the intractable disease, and detecting the specific target using aptamer-target interaction 41, 42 . Aptamers have several advantages compared to antibodies: 1) cheap production cost, 2) small molecular size, 3) easy-to-tailor for functionalization, 4) ability to tune binding affinity, 5) the ability to chemically synthesize, and 6) fast manufacturing speed 43 (Table 1) . Based on these advantages, several groups tried to fabricate a biosensor to detect cancers 44 , bacteria 45 , small molecules 46 , diseases 47 and viruses 48 . In particular, detecting highly infectious viruses requires fast manufacturing speed and high throughput screening 49 . The chemically synthesized aptamer can be a powerful agent for constructing a virus biosensor 50 . Thus, aptasensor fabrication can lead to IV biosensor development. In this review, we briefly discuss the recent trends in aptasensor for detecting IV virus using an optical method widely used in the field and an electrochemical method that is advantageous in miniaturization, portability, easy-to-handle it, user-friendly interface and has a very high sensitivity 51 . In virus detection, diagnostic tools need to be accurate, fast, and specific. To ensure wide use and mass production, it must be easy-to-use and low-cost 51 . In light of these aspects, electrochemical detection methods are very attractive tools for virus detection. Electrochemical biosensors require fewer samples and are highly sensitive. In addition, it is easy to downsize the device, and it can be manufactured at a low cost 52 . Due to the above-mentioned advantages, research on the electrochemical biosensor using an aptamer has been actively conducted 51 . A typical electrochemical aptasensor research method screens aptamers using SELEX and selects aptamers with a low dissociation constant (K D ) among the proposed aptamer candidates. The selected aptamer is immobilized on a substrate to bind with the target virus. At this stage, according to the type of transducer, it is Table 1 . Comparison between aptamer and antibody for IV detection biosensor construction. analyzed by checking the signal change using amperometric 53 , voltammetric 54 , potentiometric 55 , or impedimetric methods 56 . Notably, Bhardwaj's group conducted SELEX using recombinant influenza A mini-HA protein, and eleven aptamer sequences were obtained as a result 57 . K D values were determined for each aptamer sequence using qPCR. It was confirmed that V46 and V57 showed low K D values of 19.2 nM and 29.6 nM, and they showed affinities similar to antibodies. Thereafter, ITO glass was immersed in a solution containing NH 4 OH, H 2 O 2 , and H 2 O at 60°C to form a hydroxyl group on the surface. The modified ITO was reacted with 1% polyethylenimine (PEI) solution for two hours and before incubating with a negatively charged V46 aptamer. To remove the physically adsorbed aptamer, it was immersed in ultrapure water and treated with 1% BSA solution to block the surface activation site (Figure 1(A) ). Figure 1 (B) shows that the fabricated aptasensor was subjected to cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in 1X PBS (pH 7) containing 5 mM [Fe(CN) 6 ] 3-/4and 0.5 M KCl. CV was performed to test the binding affinity of the V46 and V57 aptamers, and the limit of detection (LOD) of the aptasensor was determined using DPV. As a result, the LOD of the produced aptasensor was 3.7 PFU/mL and it showed high reproducibility ( Figure 1 (D)). In addition, it showed high selectivity by reacting with H1N1 subtypes and not with other influenza viruses ( Figure 1 (C)). Meanwhile, research into improving the performance of an electrochemical biosensor using nanomaterials is actively being conducted 58-60 . The specific surface area was increased by insituating the nanomaterial to the substrate surface. The bioprobe immobilized to the surface increases the chance of recognizing analyte and increases the intensity of the redox current, thus increasing sensitivity. In addition, carbon nanotubes, graphene, and gold nanomaterials, which are used in electrochemical biosensors, have excellent electrical properties 61 . An example of improving the performance of an electrochemical sensor using nanomaterials is a recently reported study by Lee's group 54 . Figure 2 (A) shows a schematic image of this study. The aptamer sequence that selectively binds the HA protein of H5N1, the DNAzyme sequence that generates an electrochemical signal, and the sequence containing the thiol group so that it can be immobilized on the substrate, are composed of a 3 way junction (DNA 3WJ) and used as a bio probe. The signal was amplified using porous gold nanoparticles (pAuNP) with a diameter of 60-110 nm. Figure 2 (B) showed the schematic diagram of DNA 3WJ and the results of TBM-PAGE performed to confirm that DNA 3WJ was correctly formed. Cysteamine, pAuNP, and DNA 3WJ were applied to the prepared electrode, immobilized using a self-assembly method, and treated with 1 mM hemin. The hemin molecule has a single guanine sequence of the DNAzyme sequence, a Gquadruplex DNA structure, and activity similar to peroxidase. The fabrication process was confirmed using an atomic force microscope (AFM) and CV, and the electrode immobilized with pAuNP was confirmed to have higher electrical activity than the bare electrode. The performance of the sensor was confirmed by CV and had a linear range of 1 pM to 100 nM HA protein. The limit of detection was determined at 1 pM in chicken serum (Figure 2(C) ). This study was conducted in chicken serum and is ex-pected to be used in the field because it is label-free. So far, we have examined the influenza virus detection method using amperometric and voltammetric methods. In addition, impedicmetric methods are also widely used to measure the change in charge transfer resistance (R ct ) as a biorecognition event occurs on the working electrode surface. In the study by Bai's group, influenza virus H1N1 was detected using the impedimetric method described above 62 . After selecting a candidate aptamer using SELEX, K D was determined by using an enzyme-linked oligonucleotide assay (ELONA) method, and LOD was confirmed. As a result, experiments were conducted using A20S and A8S8 with the lowest K D , and the LOD of direct ELONA were 2 ng/µL and 0.3 ng/µL. Next, an electrochemical impedance spectroscopy (EIS) aptasensor was fabricated. After polishing the gold electrode, CV was performed at a rate of 0.1 V/s between -0. steps were confirmed through EIS. EIS was measured in PBS containing 1 M NaCl, 5 mM K 3 Fe(CN) 6 , and 5 mM K 4 Fe(CN) 6 . The frequency range was 0.03 Hz to 200 kHz, and the amplitude was 10 mV. As a result, both increases and decreases in R ct were observed when the biorecognition event of the target and aptamer occurred, and the researchers explained these using two mechanisms. As the first factor, R ct increases because the aptamer does not fold upon non-specific binding of the target and the aptamer. Conversely, the aptamer folds upon specific binding with the target, resulting in more space for electron transport. Therefore, R ct decreases. The above-mentioned hypothesis was verified using a B virus with low affinity and H1N1 with high affinity ( Figure 3(A), (B) ). As a result, the LOD of the EIS aptasensor was improved by approximately 300 times compared to the ELONA method, which was 0.9 pg/µL. Figure 3 (C) shows the selectivity test of this sensor. It was confirmed that the signal decreased when binding with H1N1, but it increased when binding to other substances. A method of using an interdigitated electrode (IDE) to increase the impedance signal is also frequently used. The IDE is an electrode designed to engage two or more electrodes. It has a high signal/noise ratio because it maximizes the impedance change on the surface, reduces the detection time, and minimizes the interference effect of non-target analytes in solution. Furthermore, it is compact compared to other electrode systems and has advantages like fast establishment of steady state 63 . Figure 4 (A) shows an example of the IDE structure. The equivalent circuit when using the IDE of the above structure and the Nyquist plot before and after detection are shown in Figure 4 (B). Fu's group detected H5N1 using an enzyme catalyst, gold nanoparticles, and an IDE 64 . Nanocomposites were formed by coating magnetic beads (MB) with specific aptamers on H5N1 and combining concanavalin A (ConA), glucose oxidase (GOx), and gold nanoparticles. The generated complex of aptamer-coated MB, H5N1, and enzymenanocomposite were incubated to form a sandwich complex. Next, it was transferred to a glucose solution to induce an enzymatic reaction to generate gluconic acid and ionize to increase the ionic strength of the solution, thereby reducing the impedance of the IDE. This method was confirmed to have a LOD of 8×10 -4 HAU (Hemagglutinin Unit) in a 200 µL sample using high enzyme catalyst efficiency and high sensitivity of electrochemical impedance to ionic strength. Since this method is flexible, it is expected to be widely used. Table 2 showed the electrochemical biosensing techniques for IV detection, which showed the target and LOD. Optical biosensors are powerful tools to detect small molecules and real-time analytes with high sensitivity, and are low-cost analytical methods 68, 69 . The optical biosensor works by measuring the interaction between the analyte and the probe by measuring changes in optical properties like light absorption, reflection, and emission. In addition, the discovery of nanoparticles has led to signal amplification due to the optical properties of nanoparticles, resulting in more precise biosensor development 70 . Detection methods like fluorescence 71 , colorimetric 72 , surface plasmon resonance 73 , and Raman spectroscopy 74 are mainly used as optical biosensor methods for detecting viruses. Fluorescent biosensors are useful for real-time detection, and they achieve a million-time higher sensitivity and faster response than absorption by labeling the analyte or probe in advance. The fluorescent biosensor uses a fluorescent dye like a quantum dot (QD) to detect the target material by increasing or decreasing the fluorescent signal. Xu's group labeled a QD for fluorescence signal at the DNA 3'-end, which is a sequence complementary to the aptamer to detect avian influenza H5N1. The fluorescence signal is quenched when there is no target substance, but it increases after binding to the target 75 . Hemagglutination unit (HAU) has a detection limit of 0.4 and a detection range of 2 -1.2 to 26 /HAU 20ul -1 . Pang's group developed a method to effectively amplify the fluorescence signal and detect the influenza virus without the fluorescent dye label 76 . It is used to bind the aptamer to Ag 2 SiO 2 particles and form a G-quadruplex structure when the aptamer is combined with a target. The thiazole orange molecule floating freely in solution hardly exhibits fluorescence, but the G-quadruplex structure acts as a ligand and binds. The metal-enhanced fluorescence effect by nanoparticles shows a strong fluorescence signal. It was confirmed that the developed MEF sensor had a detection limit of rHA in buffer and 3.5 ng/mL in human serum. The surface plasmon resonance biosensor utilizes the resonance phenomenon of the surface plasmon wave that occurs when light energy is absorbed from the surface of a conductive material 77 . Among them, a phenomenon in which local vibration occurs on the surface of a metal nanoparticle having a local surface is called a local surface plasmon resonance phenomenon (LSPR). Lee's group developed an LSPR biosensor capable of detecting avian influenza (AIV H4N1) by making a DNA 3WJ using the multi-functional aptamer 78 . A schematic diagram is shown in Figure 5 (A). The researchers fabricated a DNA 3WJ structure instead of using single-stranded DNA as a probe to detect H5N1. The assembled DNA 3WJ can function as a multifunctional probe capable of performing three functions through functionalization of each strand. The fabricated DNA 3WJ has an aptamer capable of binding influenza HA, a FAM dye, and a thiol group for signal amplification and surface immobilization. Selective binding of a DNA 3WJ to influenza HA was confirmed using TBM PAGE gel results in Figure 5 (B). In addition, hollow Au spike-like nanoparticles were used to create the LSPR effect. The produced LSPR biosensor performance test results are shown in Figure 5 (C). Performance was first tested with various concentrations of HA protein in PBS buffer and before testing in chicken serum diluted 10-fold. Both experiments confirmed the linear relationship between HA protein and LSPR intensity, and each LOD was confirmed to be 1 pM. In addition, an increase in the LSPR intensity for the HA protein was evident in the selectivity experiment, and there was little increase in the LSPR intensity between the negative controls. Since most of the aptamers for detecting influenza target a specific protein HA, there were no aptamers that simultaneously bind to different sites. In other words, little research has been done on aptamerbased sandwich-type virus sensors. Kim's group recently developed immobilization-free SELEX and developed lateral flow strips that detect entire H5N2 virus particles using a pair of aptamers capable of binding to target molecules in a sandwich manner 79 . Figure 6 (A) shows the graphene-oxide based immobilization-free screening method for developing an ssDNA aptamer capable of binding to the avian influenza virus particle. Figure 6 (B) shows the GO-FRET assays for aptamer characterization. GO-SELEX without immobilization is a method in which GO is adsorbed to ssDNA labeled with FAM through π-π stacking. ssDNA capable of binding to target molecules can be separated from GO due to structural changes. The released aptamers showed fluorescence, and the adsorbed aptamers were quenched by GO. As a result, aptamers that specifically bind only to avian virus particles were characterized. A schematic diagram of the aptamer-based sandwich side flow strip biosensor was developed as shown in Figure 6 (C). In addition, actual experimental results are shown according to various concentrations (from left to right: 0, 1.5 × 10 5 , 3 × 10 5 , 6 × 10 5 , 1.2 × 10 6 , 2.5 × 10 6 , 5 × 10 6 , 1 × 10 7 EID 50 /ml) of the target virus. Using two aptamers capable of binding to one target at the same time has the advantage that sensitive detection using aptamer labels is possible without labeling the target molecule. In particular, oligonucleotides are useful for being used as secondary binding probes because they are easy to synthesize and modify. The range of 6×10 5 -1×10 7 EID 50 /ml can be detected by the naked eye, and the detection limit was estimated to be 1.27×10 5 EID 50 /ml through the calibration plot shown in Figure 6 (D). Raman spectroscopy is a very attractive tool for biosensor applications because it can confirm the composition and structure of biomaterials at the molecular level 80 . In addition, due to the multi-peak, it is possible to detect multiple components with high sensitivity, and only a few samples are used. However, the disadvantage is that the signal strength is very weak. Metal nanoparticles were introduced to overcome this disadvantage. It has been found that Raman signals are enhanced by metal nanoparticles that cause plasmon resonance, and biosensors that have introduced them are being studied. Kukushkin's group conducted a sandwich SERS assay using two different aptamers with high sensitivity for HA 81 . After fixing the thiol-attached primary aptamer to Ag particles, the virus was bound to generate a Raman signal through a secondary aptamer bound to Cy3, resulting in 10 6 -10 9 -fold signal amplification. The detection limit was confirmed to detect up to 10 -4 HA units per probe, showing that it was possible to recognize various strains of influenza virus including H1, H3, and H5 HA subtypes. Table 3 shows the optical biosensing techniques for detecting IV discussed in this review. So far, we have reviewed at methods of detection using the HA protein of IV. However, there is also a method of detecting IV using an internal protein with few mutations 82,83 . Historically, the outbreak of IV changed the history in the world, and notable examples include Spanish flu, Hong Kong influenza virus, swine flu, and avian influenza. Governments tried to control the social exchange in person to block the spread of IV infections by changing personal lifestyle and establishing policies affecting hygiene, sanitation, and healthcare. Furthermore, viruses with various mutations might appear again and serious impact on the human life. IV spread of various subtypes caused economic loss, a number of victims (humans and animals), and ethnic problems. As we discussed in this review, the aptamer-based electrochemical biosensor and optical biosensor can be powerful candidates for early IV diagnosis. The aptamer-based biosensor has several advantages compared to the antibody-based biosensor: 1) The aptamer can be manufactured chemically, decreasing the biosensor production time. 2) The screening speed of an aptamer against an unknown virus is faster than with an antibody. 3) It can be easily modified with chemical modification. These advantages showed the possibility of commercializing field-ready aptamer-based biosensors. However, some limitations should be attended to alter the antibody-based biosensor including low affinity between target-aptamer, less stability, selectivity, reliability, clinical sensitivity, and feasibility issues. Nevertheless, the aptamer-based biosensor is still attractive for IV detection, and it can be integrated with wearable electronics and a field-ready diagnosis system that contributes to the preventing the spread of various viruses. of exosomal nucleic acids and protein markers) funded by the Ministry of Trade, Industry and Energy (MOTIE, Korea) Global epidemiology of bat coronaviruses Middle East respiratory syndrome The pathogenesis and treatment of the Cytokine Storm in COVID-19 Epidemiological and clinical characteristics of 99 cases of 2019 novel coronavirus pneumonia in Wuhan, China: a descriptive study Zika Response Working Group. Zika virus: medical countermeasure development challenges Zika virus in the Americas-yet another arbovirus threat European Research Network on Recognising Serious Infection investigators. Diagnostic value of clinical features at presentation to identify serious infection in children in developed countries: a systematic review The global distribution and burden of dengue Filoviral immune evasion mechanisms Differentiation of influenza B virus lineages Yamagata and Victoria by real-time PCR Comparison of the mutation rates of human influenza A and B viruses Native morphology of influenza virions Assembly and budding of influenza virus Isolation of influenza C virus from pigs and experimental infection of pigs with influenza C virus Influenza B virus in seals Filamentous influenza viruses The structure of the influenza A virus genome A supramolecular assembly formed by influenza A virus genomic RNA segments New world bats harbor diverse influenza A viruses What really happened during the 1918 influenza pandemic? The importance of bacterial secondary infections Estimates of the reproduction number for seasonal, pandemic, and zoonotic influenza: a systematic review of the literature Cases of swine influenza in humans: a review of the literature A current review of avian influenza in pigeons and doves (Columbidae) Rapid diagnosis of influenza: state of the art Discordant detection of avian influenza virus subtypes in time and space between poultry and wild birds; Towards improvement of surveillance programs Current approaches for diagnosis of influenza virus infections in humans Detection methods of human and animal influenza virus-current trends Immunosensor-based label-free and multiplex detection of influenza viruses: State of the art Utility of reverse transcriptase PCR for rapid diagnosis of influenza a virus infection and detection of amantadine-resistant influenza a virus isolates Development of the troponin detection system based on the nanostructure. Micromachines Recent advances in AIV biosensors composed of nanobio hybrid material In vitro evolution of nucleic acids Bioimaging of nucleolin aptamer-containing 5-(N-benzylcarboxyamide)-2′-deoxyuridine more capable of specific binding to targets in cancer cells Electrochemical biosensors based on nucleic acid aptamers In vitro selection of RNA molecules that bind specific ligands Methods for measuring aptamer-protein equilibria: a review Multiple GO-SELEX for efficient screening of flexible aptamers Outlook for aptamers after twenty five years DNA aptamers in the diagnosis and treatment of human diseases A multivalent DNA aptamer specific for the B-cell receptor on human lymphoma and leukemia Aptamers: problems, solutions and prospects Current advances in aptamers for cancer diagnosis and therapy Aptamer based high throughput colorimetric biosensor for detection of staphylococcus aureus Fabrication of electrochemical biosensor composed of multi-functional DNA/rhodium nanoplate heterolayer for thyroxine detection in clinical sample Fabrication of troponin I biosensor composed of multi-functional DNA structure/Au nanocrystal using electrochemical and localized surface plasmon resonance dual-detection method Development of a HIV-1 virus detection system based on nanotechnology Rapid identification of specific DNA aptamers precisely targeting CD33 positive leukemia cells through a paired cell-based approach Aptamers as quality control tool for production, storage and biosimilarity of the anti-CD20 biopharmaceutical rituximab Aptasensors for viral diagnostics Recent trends in rapid detection of influenza infections by bio and nanobiosensor Electrochemical DNA biosensor based on a tetrahedral nanostructure probe for the detection of avian influenza A (H7N9) virus Fabrication of electrochemical biosensor consisted of multi-functional DNA structure/porous au nanoparticle for avian influenza virus (H5N1) in chicken serum Immediate detection of living bacteria at ultralow concentrations using a carbon nanotube based potentiometric aptasensor High sensitivity point-of-care device for direct virus diagnostics Subtyping of influenza A H1N1 virus using a label-free electrochemical biosensor based on the DNA aptamer targeting the stem region of HA protein Recent progress in nanomaterial-based electrochemical biosensors for pathogenic bacteria Recent Advances in Carbon Nanomaterials as Electrochemical Biosensors Recent advances in electrochemical biosensors based on fullerene-C60 nano-structured platforms Nanomaterials based electrochemical sensors for biomedical applications Aptamer selection and application in multivalent binding-based electrical impedance detection of inactivated H1N1 virus Novel impedimetric aptasensor for label-free detection of Escherichia coli O157: H7 Exploiting enzyme catalysis in ultra-low ion strength media for impedance biosensing of avian influenza virus using a bare interdigitated electrode Electrochemical detection of avian influenza virus H5N1 gene sequence using a DNA aptamer immobilized onto a hybrid nanomaterial-modified electrode Amperometric bioaffinity sensing platform for avian influenza virus proteins with aptamer modified gold nanoparticles on carbon chips Electrochemical DNA biosensor based on a tetrahedral nanostructure probe for the detection of avian influenza A (H7N9) virus Optical biosensors for label-free detection of small molecules Advanced evanescent-wave optical biosensors for the detection of nucleic acids: An analytic perspective High-throughput living cell-based optical biosensor for detection of bacterial lipopolysaccharide (LPS) using a red fluorescent protein reporter system A gold nanorods-based fluorescent biosensor for the detection of hepatitis B virus DNA based on fluorescence resonance energy transfer Colorimetric detection of hepatitis B virus (HBV) DNA based on DNA-templated copper nanoclusters A SPR aptasensor for detection of avian influenza virus H5N1 Rapid and sensitive detection of rotavirus molecular signatures using surface enhanced Raman spectroscopy A target-responsive and size-dependent hydrogel aptasensor embedded with QD fluorescent reporters for rapid detection of avian influenza virus H5N1 A fluorescent aptasensor for H5N1 influenza virus detection based-on the core-shell nanoparticles metal-enhanced fluorescence (MEF) Highly sensitive localized surface plasmon resonance immunosensor for label-free detection of HIV-1. Nanomed Label-free localized surface plasmon resonance biosensor composed of multi-functional DNA 3 way junction on hollow Au spike-like nanoparticles (HAuSN) for avian influenza virus detection Specific detection of avian influenza H5N2 whole virus particles on lateral flow strips using a pair of sandwich-type aptamers SERSbased diagnosis and biodetection Highly sensitive detection of influenza virus with SERS aptasensor A self-calibrating electrochemical aptasensing platform: Correcting external interference errors for the reliable and stable detection of avian influenza viruses Rapid and background-free detection of avian influenza virus in opaque sample using NIR-to-NIR upconversion nanoparticle-based lateral flow immunoassay platform The authors declare no competing financial interests.