key: cord-0744512-j6wcynl8 authors: Morehouse, Zachary P.; Samikwa, Lyson; Proctor, Caleb M.; Meleke, Harry; Kamdolozi, Mercy; Ryan, Gabriella L.; Chaima, David; Ho, Antonia; Nash, Rodney J.; Nyirenda, Tonney S. title: Validation of a direct-to-PCR COVID-19 detection protocol utilizing mechanical homogenization: A model for reducing resources needed for accurate testing date: 2021-08-18 journal: PLoS One DOI: 10.1371/journal.pone.0256316 sha: b42290556f86ceb98e16a6e7356ef113be91e85c doc_id: 744512 cord_uid: j6wcynl8 Efficient and effective viral detection methodologies are a critical piece in the global response to COVID-19, with PCR-based nasopharyngeal and oropharyngeal swab testing serving as the current gold standard. With over 100 million confirmed cases globally, the supply chains supporting these PCR testing efforts are under a tremendous amount of stress, driving the need for innovative and accurate diagnostic solutions. Herein, the utility of a direct-to-PCR method of SARS-CoV-2 detection grounded in mechanical homogenization is examined for reducing resources needed for testing while maintaining a comparable sensitivity to the current gold standard workflow of nasopharyngeal and oropharyngeal swab testing. In a head-to-head comparison of 30 patient samples, this initial clinical validation study of the proposed homogenization-based workflow demonstrated significant agreeability with the current extraction-based method utilized while cutting the total resources needed in half. The COVID-19 global pandemic caused by SARS-CoV-2 has dominated the clinical and research landscapes since its designation by the World Health Organization in March of 2020 [1] . Stretching to all corners of the globe, SARS-CoV-2 has been detected in most communities causing activation of public health efforts geared towards disease surveillance and prevention practices [2] [3] [4] . Efficient and effective SARS-CoV-2 detection methods are the cornerstone of these public health efforts [2] [3] [4] . Following the common detection method of many other positive-sense RNA respiratory viruses, reverse transcriptase polymerase chain reaction (RT-PCR) testing quickly emerged as the global standard for accurate SARS-CoV-2 detection from patient samples [3, 4] . Due to their high sensitivity for viral detection, nasopharyngeal and oropharyngeal swabs are widely used sample types obtained from patients for the purpose of RT-PCR based COVID-19 testing [3] . In the traditional model of RT-PCR viral testing, swab samples are collected from the patient, stored in viral transport media at the collection site, and sent to the laboratory for processing via molecular techniques including viral RNA extraction and purification utilizing a series of chemical reagents followed by RT-PCR for viral detection [3, 5, 6] . While proven effective, this traditional model requires a significant quantity of consumable plastics and chemical reagents to complete, particularly in the extraction and purification steps that include multiple rounds of digestions and different buffer washes [7] . As the COVID-19 pandemic spread, the international supply of the common reagents and plastics used in viral genetic extractions and RT-PCR testing became increasingly stressed reducing access to adequate testing and driving up prices to health systems and patients [7] . With the demand for testing increasing secondary to viral spread throughout communities, the need for cost effective and accurate diagnostic capabilities drove the innovation of novel viral detection methodologies [3, 4, 6, 7] . One way to reduce cost and increase access to SARS--CoV-2 testing is to reduce the resources needed for detection, without reducing the sensitivity of the testing assays. Technologies such as isothermal PCR reactions, direct-to-PCR testing procedures, and colorimetric PCR-based viral detection methodologies have all been proposed to address the issue of access to accurate testing in a resource challenged setting [8] [9] [10] . Herein, the authors are utilizing a mechanical homogenization based direct-to-PCR viral detection method for SARS-CoV-2 detection from nasopharyngeal and oropharyngeal swabs to screen for both symptomatic and asymptomatic COVID-19 in Blantyre, Malawi. This homogenization based direct-to-PCR viral detection workflow was previously examined utilizing in vitro simulated nasopharyngeal swab samples spiked with clinically significant levels of human coronavirus 229E (HCoV-229E) for proof of concept testing [10] . In the initial study, the laboratory simulated samples processed using this novel methodology revealed a limit of detection of 1.2x10 3 viral copies/mL with 96.30% sensitivity when detecting HCoV-229E [10] . While this technology has been reported as a proof of concept, in vitro observation, this brief manuscript examines the clinical feasibility and efficiency of this methodology [10] . In a head-to-head comparison of the direct-to-PCR testing and the traditional extraction-based PCR testing methods, asymptomatic and mild to moderately symptomatic patients were screened with both methods for SARS-CoV-2 detection. The upper respiratory tract samples used for this method validation study were obtained through the University of Malawi College of Medicine (Blantyre, Malawi). All samples were obtained with informed patient consent following the COVID-HCWEXPO protocols in IRB contract P.05/20/3053 approved by the Institutional Review Board of the University of Malawi College of Medicine (Blantyre, Malawi). Informed consent was obtained from all subjects involved in the study prior to participation. The study recruited participants over the age of 18 and consent was obtained via written consent by each participant and witnessed by the researcher collecting the sample. Upper respiratory tract samples were obtained from a prospective cohort study to compare the risk of SARS-CoV-2 infection and exposure in healthcare workers compared to collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the 'author contributions' section. Competing interests: Z.P.M., C.M.P., G.L.R., and R.J.N. disclose that they are all currently employed by Omni International Inc, A PerkinElmer Company in some capacity, however, none of the authors have any personal financial interests in the success or failure of the company. R.J.N. also discloses that he is the founder and CEO of Jeevan BioSciences with personal financial interests in its success or failure. All authors declare that their our competing interests do not alter our adherence to PLOS ONE policies on sharing data and materials. community members in Blantyre, Malawi between June and August 2020 (manuscript in preparation). 15 SARS-CoV-2 PCR positive and 15 SARS-CoV-2 PCR negative were randomly selected from the cohort of 300 adult participants. (Table 1) . Patients presenting to the hospital with suspected severe COVID-19 in respiratory distress were excluded from this study. At the time of sample collection, each patient provided two swab specimens, one nasopharyngeal swab and one oropharyngeal swab which were immediately stored in a single tube containing viral transport media to await further processing [5, 11] . Following sample collection, samples were stored at 4 C for up to 24 hr, if the sample was not going to be processed within the next 24 hr it was stored at -80 C until processing could occur. One mL of viral transport media was taken from the tube containing the nasopharyngeal and oropharyngeal swabs at room temperature and utilized in the Omega Bio-Tek Mag-Bind Viral DNA/RNA Kit in accordance with manufactures guidelines (Omega Bio-Tek, Cat. No. M6246). Final product of purified viral RNA was held on ice in preparation for PCR testing. Direct-to-PCR COVID-19 testing for resource limited settings One mL of viral transport media was transferred from the original sample collection tube to a 2 mL screw cap tube (Omni International Inc, Cat. No. 19-647) and sealed. Sample tubes were then loaded into the Omni Bead Ruptor Elite (Cat. No. 19-647) for processing [10] . The samples were run at 4.2 m/s for 30 s, removed from the device, and allowed to sit for 60s following processing to allow for any forth in the tubes to settle [10] . Following Table 1 ) [11] . Direct-to-PCR COVID-19 testing for resource limited settings When comparing the extraction and homogenization-based sample preparation techniques described above, the final Ct values resulting from each method were paired under the original patient identification number for direct comparison. For the purpose of statistical analysis of the final results, negative samples where no amplification was detected in the presence of confirmed internal controls, were assigned a Ct value of 45.0. The positive predictive value (PPV) and negative predictive value (NPV) for the homogenization-based workflow were calculated using the extraction-based workflow as the gold standard method to compare against (Table 2) . Additionally, the two resultant Ct values linked to the same patient from each testing method were plotted against each other for correlative visualization and a standard best fit line was produced to evaluate the R 2 value (Fig 2) . When directly comparing the capabilities of homogenization-based, direct-to-PCR workflow to traditional, extraction-based methodology for SARS-CoV-2 detection off nasopharyngeal and oropharyngeal swabs there was an overall 80% agreeability between both methods. A strong positive correlation was observed when plotting Ct values produced utilizing both examined methods linked to the same patient sample as demonstrated with an R 2 of 0.763 (Fig 2) . Except for one patient, all paired positive samples show a Ct value following homogenization-based testing to be greater than the extraction-based testing for the same patient (Fig 1 and Table 2 ). However, there were noted to be 6 positive samples that demonstrated disagreement following processing under both methodologies, where a sample was Ct positive for SARS-CoV-2 utilizing one method and not the other (Table 2 ). There was an equal distribution of disagreement between both testing methodologies with 3 of 30 patients testing positive for COVID-19 with extraction-based testing (patients 13, 14, and 15) and negative with the homogenization-based testing, and then the reverse with 3 of 30 patients testing positive for COVID-19 with homogenization-based testing (patients 16, 19, and 29) and negative with extraction-based testing ( Table 2 ). These disagreements in SARS-CoV-2 detection were observed in samples which had results of Ct values greater than 37.08, indicating a low viral load (Tables 1 and 2) . When comparing Ct values below 37.08, there was a 100% agreement for detection of SARS-CoV-2 utilizing both methodologies (Table 2 ). In this clinical validation study, we utilized 30 paired nasopharyngeal and oropharyngeal swab samples participants in a prospective cohort study to assess the occupational risk of SARS--CoV-2 infection or exposure in Blantyre, Malawi to examine the efficacy of a direct-to-PCR, homogenization-based workflow when compared to the gold standard extraction-based workflow for detection of SARS-CoV-2. 80% agreeability between all samples following processing was noted, with a positive direct correlation between the resultant Ct values produced when processing each sample with both methods. An R 2 of 0.763 and positive predictive value of 80% demonstrate a moderate level of acceptability for implementing the proposed direct-to-PCR method into clinical practice. Additionally, when moving the negative detection cut off Ct value from 40.0 to 37.0 the improvement of both the positive predictive value and negative Direct-to-PCR COVID-19 testing for resource limited settings predictive value to 100% and agreement of 100% between both methodologies warrants further investigation while strengthening the argument for clinical implementation. Throughout the progression of the COVID-19 global pandemic, the need for efficient and effective diagnostic testing has proven paramount to the global response, with PCR based viral detection off swabs serving as the current gold standard for testing [2] [3] [4] . However, the traditional extraction-based methodology detailed in this manuscript requires many chemical reagents to complete and has become financially burdensome secondary to strain placed on the global supply chains for many of these reagents and consumable plastics. The increase in demand for the supplies needed to complete the traditional extraction-based method coupled with the limited global supply for the reagents created a scenario where many wealthy countries and communities were able to purchase all of the supplies needed for testing, leaving resource challenged settings struggling to ensure availability of timely and accurate viral detection methods. In addition to the high cost associated with the accurate extraction-based workflow, the total run time for each sample to be processed in this method can take up to 3 hours from extraction to PCR results when using a fully automated workflow. When receiving thousands of samples per day, a backlog can easily be created utilizing the extraction-based method causing delays in relaying critical positive or negative results to patients and local health officials. Developing approaches to reduce the total time per test while maintaining accuracy also emerged as an area of needed innovation in response to the COVID-19 pandemic. To address these limitations in viral testing many approaches have been proposed ranging from point of care, lateral flow antigen tests to rapid PCR tests that offer solutions on either time or cost associated with testing [6] [7] [8] . While many of the proposed technologies for increasing testing either reduce time or reduce required reagents, they often do not achieve both while maintaining diagnostic accuracy similar to the current extraction-based PCR workflow [6, 7] . Herein, the validation of the proposed direct-to-PCR, homogenization-based methodology offers a solution through reducing the time and reagents needed to process each sample while maintaining an acceptable level of accuracy when compared to the extractionbased method. Of note, the demonstrated agreeability between the direct-to-PCR and traditional methods displayed a pattern of all except for one of the SARS-CoV-2 positive samples had a lower Ct value following the extraction protocol versus the homogenization protocol. This is representative of the PCR inhibitors present in the lysate following homogenization that are not removed due to the lack of chemical purification steps when compared to the extraction protocols. Given the presence of inhibitors, it is expected that the Ct values are greater than the purified samples from kit-based extractions. However, the high agreeability in detecting SARS-CoV-2 between the methods demonstrates that these inhibitors remaining in the lysate transferred to the RT-qPCR in the homogenization method do not prohibit adequate RNA amplification for detection. This pattern confirmed with a strong R 2 value when plotting Ct values from both methods against each other supports the reliability of the direct-to-PCR workflow when dealing with the variability of viral loads in a clinical sample. While we acknowledge that this initial clinical validation study demonstrated inconsistent detection when the Ct values were greater than 37, the 100% positive predictive value and 100% negative predictive value at Ct values less than 37 qualifies this methodology for further large-scale evaluations ( Table 2 ). It has been documented that between commercially available kits there is decreasing agreement on SARS-CoV-2 detection as Ct values grow past 36 [12] [13] [14] . The authors acknowledge that this manuscript has its limitations in statistical robustness and the limited data it provides, such as the lack of technical replicates or viral load quantifications. However, we felt it was prudent to disseminate the limited information we have developed around this novel process for viral detection in an effort to assist in the current international need for COVID-19 testing innovation and improvement. It is our hope that this efficient and cost-effective measure for COVID-19 PCR based testing can work to fill the void in testing in many areas of the world. Using the small mechanical footprint of a bench top homogenizer and a standard thermocycler, and without the need of a multitude of chemical reagents, the direct-to-PCR workflow can be set up almost anywhere. The ease of system configuration and simple operational steps needed to complete this workflow support the adaptability of this novel method to be implemented in any area, including resource challenged settings without the funds or laboratory spaces to support fully automated extraction based viral testing systems. It is critical that we as a global community continue to commit to the development of testing strategies to assist in COVID-19 public health efforts in all areas of the world if we are going to implement successful pandemic mitigation efforts. Given the high levels of agreeability between the observed workflows, in conjunction with the significant reduction in cost and processing time by utilizing a 30 second mechanical homogenization step versus an hour-long reagent heavy extraction procedure, this direct-to-PCR methodology has potential to be further incorporation into global COVID-19 detection strategies. Herein, we believe our novel direct-to-PCR workflow is a potential solution to increase access to efficient SARS-CoV-2 detection in resource challenged areas. Writing -review & editing: Zachary P. Morehouse, Lyson Samikwa, Caleb M. Proctor, Gabriella L. Ryan, David Chaima, Antonia Ho, Rodney J. Nash, Tonney S. Nyirenda. WHO Declares COVID-19 a Pandemic The Need for More and Better Testing for COVID-19 Diagnostic Testing for Severe Acute Respiratory Syndrome-Related Coronavirus 2: A Narrative Review Changing agendas and priorities of public health associations across the globe following in the era of COVID-19 pandemic-A mini-review How to Obtain a Nasopharyngeal Swab Specimen COVID-19 Clinical Diagnostics and Testing Technology Laboratory Diagnosis of COVID-19: Current Issues and Challenges Point-of-care bulk testing for SARS-CoV-2 by combining hybridization capture with improved colorimetric LAMP SARS-CoV-2 Direct Detection Without RNA Isolation With Loop-Mediated Isothermal Amplification (LAMP) and CRISPR-Cas12. Front Med (Lausanne) A novel two-step, direct-to-PCR method for virus detection off swabs using human coronavirus 229E Interim Guidelines for Collecting, Handling, and Testing Clinical Specimens from Persons for Coronavirus Disease Laboratory Tests for COVID-19: A Review of Peer-Reviewed Publications and Implications for Clinical Use Negative Nasopharyngeal and Oropharyngeal Swabs Do Not Rule Out COVID-19 Detection of SARS-CoV-2 in Different Types of Clinical Specimens The authors would like to acknowledge and thank Dr. Karl Seydel of Michigan State University and the University of Malawi for his role in bringing all parties together to kickstart this research endeavor. Furthermore, we acknowledge Pete Tortorelli and Karl Jahn of Omni International Inc for their organizational support of this project and the leadership team at Omega Bio-Tek for their donation of the Mag-Bind kits to support this testing. Additionally, we would like to thank Rachel True, Rachel Nash, and Leah Proctor for their constant support of our research. Conceptualization: Zachary P. Morehouse. Direct-to-PCR COVID-19 testing for resource limited settings