key: cord-0741735-56rn6d6o authors: Santarpia, Joshua L.; Rivera, Danielle N.; Herrera, Vicki L.; Morwitzer, M. Jane; Creager, Hannah M.; Santarpia, George W.; Crown, Kevin K.; Brett-Major, David M.; Schnaubelt, Elizabeth R.; Broadhurst, M. Jana; Lawler, James V.; Reid, St. Patrick; Lowe, John J. title: Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care date: 2020-07-29 journal: Sci Rep DOI: 10.1038/s41598-020-69286-3 sha: fc4bb9e664fb2c1d99d2060359372eff58a4e13a doc_id: 741735 cord_uid: 56rn6d6o The novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) originated in Wuhan, China in late 2019, and its resulting coronavirus disease, COVID-19, was declared a pandemic by the World Health Organization on March 11, 2020. The rapid global spread of COVID-19 represents perhaps the most significant public health emergency in a century. As the pandemic progressed, a continued paucity of evidence on routes of SARS-CoV-2 transmission has resulted in shifting infection prevention and control guidelines between classically-defined airborne and droplet precautions. During the initial isolation of 13 individuals with COVID-19 at the University of Nebraska Medical Center, we collected air and surface samples to examine viral shedding from isolated individuals. We detected viral contamination among all samples, supporting the use of airborne isolation precautions when caring for COVID-19 patients. www.nature.com/scientificreports/ in the NBU on day 18, after Patient 3 had been admitted to the unit for four days. We obtained surface samples, high-volume [50 L/min (Lpm)] air samples, and low-volume (4 Lpm) personal air samples. The surface samples came from common room surfaces, personal items, and toilets. Personal air sampling devices were worn by study personnel on two days during sampling of NBU and NQU rooms. During the sampling, individuals in isolation were recording symptoms and oral temperatures twice a day. The maximum temperature, during the three days preceding sampling, was recorded, as was the presence of any symptoms. During this time, 57.9% of patients recorded a temperature greater than 37.2 °C (99.0 °F), and 15.8% had a temperature greater than 37.8 C (100 °F). Independent of temperature, 57.9% of patients reported other symptoms, primarily cough. Surface and aerosol samples were analyzed by RT-PCR targeting the E gene of SARS-CoV-2 10 . Of the 163 samples collected in this study, 121 (72.4%) had a positive PCR result for SARS-CoV-2. Due to the need to cause minimal disruption to individuals in isolation and undergoing hospital care, the precise surface area sampled in this study was not uniform, so results are presented as concentration of gene copies present in the recovered liquid sample (copies/µL). Viral gene copy concentrations recovered from each sample type were generally low and highly variable from sample to sample ranging from 0 to 1.75 copies/µL (Fig. 1A , and Tables S1 and S2), with the highest concentration recovered from an air handling grate in the NBU. Both the sampling time and flow rate were known for all aerosol samples collected in this study, therefore the airborne concentration was calculated for all air samples (copies/L of air; Tables S1 and S2). Overall, 70.6% of all personal items sampled were determined to be positive for SARS-CoV-2 by PCR (Fig. 1B and Table S1 ). Of these samples, 75.0% of the miscellaneous personal items (described in the "Methods" section) were positive by PCR, with a mean concentration of 0.22 copies/µL. Samples of cellular phones were 77.8% Figure 1 . A Box and whisker plot demonstrating the max and min (whiskers), median (line) and 25th and 75th percentile gene copy concentrations (copies/µL) for all types of samples collected in this study. Data is presented as a concentration in recovered buffer (sterile PBS) for each sample. Surface samples were in a total of 18 mL (3 mL to pre-moisten and 15 mL to recover), bedroom air and hallway air samples were recovered in 15 mL total, while personal air samples were recovered in 10 mL of sterile PBS. B Percentage of positive samples recovered in each room sampling. Bar patterns from the same room and same individual on multiple dates are identical. www.nature.com/scientificreports/ positive for viral RNA (0.17 copies/µL mean concentration) and remote controls for in-room televisions were 55.6% percent positive (mean of 0.22 copies/µL). Samples of the toilets in the room were 81.0% positive, with a mean concentration of 0.25 copies/µL. Of all room surfaces sampled (Fig. 1B and Table S1 ), 75.0% were positive for SARS-CoV-2 RNA. 70.8% of the bedside tables and bed rails indicated the presence of viral RNA (mean concentration 0.26 copies/µL), as did 72.7% of the window ledges (mean concentration 0.22 copies/µL) sampled in each room. The floor beneath patients' beds and the ventilation grates in the NBU were also sampled. All five floor samples, as well as 4 of the 5 ventilation grate samples tested positive by RT-PCR, with mean concentrations of 0.45 and 0.82 copies/µL, respectively. Air samples in the rooms and in the hallway spaces (Fig. 1B, and Tables S1 and S2) provide information about airborne viral shedding in these facilities. We found 63.2% of in-room air samples to be positive by RT-PCR (mean concentration 2.42 copies/L of air). In the NBU, for the first two sampling events performed on Day 10, the sampler was placed on the window ledge away from the patient (NBU Room A occupied by Patient 1), and was positive for viral RNA (Table S1 ; 2.42 copies/L of air). During the sampling event on Day 18 in NBU Room B occupied by Patient 3, one sampler was placed near the patient and one was placed near the door greater than 2 m from the patient's bed while the patient was receiving oxygen (1 L) via nasal cannula. Both samples were positive by PCR, with the one closest to the patient indicating a higher airborne concentration of RNA (4.07 as compared to 2.48 copies/L of air). Samples taken outside the rooms in the hallways were 58.3% positive ( Fig. 1B and Table S2 ), with a mean concentration of 2.51 copies/L of air. Both personal air samplers from sampling personnel in the NQU showed positive PCR results after 122 min of sampling activity (Table S2) , and both air samplers from NBU sampling indicated the presence of viral RNA after only 20 min of sampling activity (Table S2 ). The highest airborne concentrations were recorded by personal samplers in NBU while a patient was receiving oxygen through a nasal cannula (19.17 and 48.22 copies/L). Neither individuals in the NQU or patients in the NBU were observed to cough while sampling personnel were in the room wearing samplers during these events. Between 5 and 16 samples were collected from each room, with a mean of 7.35 samples per room and a mode of 6 samples per room. The percentage of positive samples from each room ranged between 40 and 100% ( Fig. 1B, 2A) . A Spearman's Rank Order Correlation (ρ) of percent positive samples and total number of samples for each room had a value of 0.33, indicating a weak relationship between the number of samples taken and the percent of positive samples observed, which is likely due to the focus of unplanned samples on areas or objects frequently used by patients. When the percent of positive samples taken was compared to the maximum reported oral temperature of the patient for the previous three days, a ρ of 0.39 indicated only a weak relationship between elevated body temperature and shedding of virus in the environment. Further, recorded oral temperature was compared with the gene copy concentration for each in-room sample type (Table S1 ). These ρ values ranged from -0.02 (cell phones) to 0.36 (air samples), indicating weak to no significant relationship between body temperature and environmental contamination, with air samples having the strongest correlation, followed by windowsills (ρ = 0.25) and remotes (ρ = 0.23). A subset of samples that were positive for viral RNA by RT-PCR was examined for viral propagation in Vero E6 cells. Several indicators were utilized to determine viral replication including cytopathic effect (CPE), immunofluorescent staining, time course PCR of cell culture supernatant, and electron microscopy. Due to the low concentrations recovered in these samples cultivation of virus was not confirmed in these experiments. Nevertheless, in two of the samples, cell culture indicated some evidence for the presence of replication competent virus ( Fig. 2 ): an air sample from the NQU hallway on day 8 and the windowsill from NQU A on day 5 (Tables S1 and S2) . Microscopic inspection of cell cultures indicated CPE after 3-4 days ( Fig. 2A,B) . Serial PCR of cell culture supernatant was unclear, but the observed changes in supernatant RNA, in the hallway sample, indicated that after an initial decrease in RNA in the supernatant (consistent with the with daily withdrawal of supernatant for analysis and replacement with fresh supernatant) some increase in viral RNA may have occurred (Fig. 2C ). The windowsill sample had consistent viral RNA in the supernatant throughout the time course, despite the daily withdrawal of supernatant for analysis, which could indicate replication (Fig. 2D ). Further, immunofluorescence images ( Taken together, these data indicate significant environmental contamination in rooms where patients infected with SARS-CoV-2 are housed and cared for, regardless of the degree of symptoms or acuity of illness. Contamination exists in all types of samples: high and low-volume air samples, as well as surface samples including personal items, room surfaces, and toilets. Samples of patient toilets that tested positive for viral RNA are consistent with other reports of viral shedding in stool 11 . The presence of contamination on personal items is also expected, particularly those items that are routinely handled by individuals in isolation, such as cell phones and remote controls, as well as medical equipment that is in near constant contact with the patient. The observation of viral replication in cell culture for some of the samples confirms the potential infectious nature of the recovered virus. We noted variability in the degree of environmental contamination (as measured by the percentage of positive samples) from room to room and day to day. In general, percent positive samples in the NQU were higher on Days 5-7 (72.5%) versus Days 8-9 (64.9%). While most NQU rooms had higher percentages of positive specimens earlier in the course of illness, three of the nine rooms (NQU B,G, and I) actually had higher percentages on later days (Days 8 and 9 respectively). On average, a higher percentage of positive samples (81.4% over 3 rooms) was detected in the NBU later in the course of illness (sampled on Days 10 and 18), suggesting that patients with higher acuity of illness or levels of care may be associated with increased levels of environmental contamination. www.nature.com/scientificreports/ www.nature.com/scientificreports/ However, the lack of a strong relationship between environmental contamination and body temperature reaffirms the fact that shedding of viral RNA is not necessarily linked to clinical signs of illness. In the hospital NBU, where patients were generally less mobile, distribution of positive samples suggests a strong influence of airflow. Personal and high-touch items were not universally positive, yet we detected viral RNA in 100% of samples from the floor under the bed and all but one window ledge (which were not used by the patient) in the NBU. Airflow in NBU suites originates from a register at the top center of the room and exits from grates near the head of the patient's bed on either side of the room. Airflow modelling 12 has suggested that some fraction of the airflow is directed under the patient's bed, which may cause the observed contamination under the bed, while the dominant airflow likely carries particles away from the patient's bed towards the edges of the room, likely passing by the windows resulting in some deposition there. Although this study did not employ any size-fractionation techniques in order to determine the size range of SARS-CoV-2 droplets and particles, the data is suggestive that viral aerosol particles are produced by individuals that have the COVID-19 disease, even in the absence of cough. First, in the few instances where the distance between individuals in isolation and air sampling could be confidently maintained at greater than 6 ft, 2 of the 3 air samples were positive for viral RNA. Second, 58.3% of hallway air samples indicate that virus-containing particles were being transported from the rooms to the hallway during sampling activities. It is likely that the positive air samples in the hallway were caused by viral aerosol particles transported or resuspended by personnel exiting the room 13, 14 . Finally, personal air samplers worn by sampling personnel were all positive for SARS-CoV-2, despite the absence of cough by most patients while sampling personnel were present. Recent literature investigating human-expired aerosol suggests that a large fraction is less than 10 µm in diameter across all types of activity (e.g. breathing, talking, and coughing 15 ) and that upper respiratory illness increases production of aerosol particles (less than 10 µm) 16 . A recent study of SARS-CoV-2 stability indicates that infectious aerosol may persist for several hours and on surfaces for as long as 2 days 17 . Our study suggests that SARS-CoV-2 environmental contamination around COVID-19 patients is extensive, and hospital IPC procedures should account for the risk of fomite, and potentially airborne, transmission of the virus. Despite wide-spread environmental contamination and limited SARS-CoV-2 aerosol contamination associated with hospitalized and mildly ill individuals, the implementation of a standard suite of infection prevention and control procedures prevented any documented cases of COVID-19 in healthcare workers, who self-monitored for 14 days after last contact with either ward and underwent two nasal swab PCR assays 24 h apart if they reported fever or any respiratory infection symptoms. The standard IPC protocols for both the NBU and NQU includes negative pressure rooms with 12-15 air-exchanges per hour, negative pressure hallways in the suite compared to outside, strict access control, highly trained staff with well-developed protocols, frequent environmental cleaning, and aerosol-protective personal protective equipment that consisted of N95 filtering facepiece respirators in the NQU and powered air purifying respirators for patient care within the NBU. Further study is necessary to fully quantify risk. High-touch personal items sampled included cellular phones, exercise equipment, television remotes, and medical equipment. Room surfaces tested included ventilation grates, tabletops, and window ledges. Toilet samples were obtained from the rim of the bowl. Air samples were collected both in isolation rooms and in the hallways of the NBU and NQU during sampling activities, while patients were present. Personal air samplers were worn by sampling personnel on two occasions during sampling activities: once during sampling at the NQU when 6 individual rooms were sampled, and once in the hospital NBU when one room was sampled. Surface and personal items were collected using 3 × 3 sterile gauze pads pre-wetted with 3 mL of phosphate buffered saline (PBS). Large area surface samples were collected by wiping in an "S" pattern in 2 directions to cover as much of the available surface as possible. Smaller items (e.g. cellular phones, remote controls) were wiped in one direction on every available surface. Following collection, samples were packed in 50 mL conical tubes. Hand hygiene and glove changes were performed between the collection of every sample. personal items. Several personal items were sampled consistently between all quarantine rooms (cellular phones and television remote controls). In addition, individuals were asked about which items they used or handled frequently, and several additional samples were collected based on those responses: exercise equipment, medical equipment (spirometer, pulse oximeter, nasal cannula), personal computers, iPads, reading glasses, and pots used to heat water. This last category was grouped together as "Miscellaneous Personal Samples". Room surfaces. Several surfaces were sampled in each room. For rooms in the National Quarantine Unit, both the windowsill and the bedside table were sampled. For rooms in the Nebraska Biocontainment Unit, samples were taken on the windowsill, the bed rail or bedside table, under the patient's bed and on the air conditioning return grate nearest the door. Air samples. Stationary air samples, both inside and outside of patient rooms, were collected using a Sartorius Airport MD8 air sampler operating at 50 Lpm for 15 min. Samples were collected onto a 80 mm gelatin filter. Samplers in patient rooms were placed on bedside tables and nightstands but at least 1 m away from the patient. No attempt was made to ensure the sampler was placed a specific distance from the individual in the room, so, while distance between sampler and individual was neither defined nor consistent, individuals in the room did not directly interact with the sampler. NQU subjects were ambulatory however, and all were out of bed during sampling. Our NQU protocol advises patients in isolation to maintain a 6-foot distance from staff members who enter their room and wear a procedure Scientific RepoRtS | (2020) 10:12732 | https://doi.org/10.1038/s41598-020-69286-3 www.nature.com/scientificreports/ mask (e.g. surgical mask) while staff are in the room. Observed adherence with these procedures was high throughout patient stays. For this study, individuals were instructed that they could remove the mask during air sampling activities; however, many individuals did not remove it and therefore the impact of infected individuals wearing masks cannot be assessed in this study. Study personnel generally left rooms during a significant period of time during air sampling, but it appeared that not all patients removed procedure masks during those periods. Hallway air samples were obtained by placing samplers on the floor approximately 10 cm from the door frame adjacent to rooms where sampling activities were taking place. Study personnel entered and exited rooms several times during air sampling. Additional personal air samples were collected by study personnel during sampling activities wearing Personal Button Samplers (SKC, Inc.) and using Air Chek pumps (SKC, Inc.) both sampling at 4 Lpm. These samples were collected onto 25 mm gelatin filters. In order to quantify the number of viral gene copies present in each sample from the measured Ct values, a standard curve was developed using synthetic DNA. A 6-log standard curve was run in duplicate beginning at a concentration of 1 × 10 3 copies/µL. The data was fit with the exponential function: where Ct is the cycle time where amplification is definitive. The equation was then used to convert all measured Ct values from all samples into gene copy concentrations. The minimum concentration detected by this assay was 1e −1 copies/µL at between 39 and 44 cycles. Considering a 5 µL sample volume, the derived exponential function above, and the uncertainty in the efficiency of RNA extraction amplification beyond 39.2 is treated as undetected, which equates to 1 copy in 5 µL of recovered sample. The average and standard deviation concentrations were calculated from the triplicate PCR runs for each sample. The primers and probe used in this study (below) are based on a previously published assay 10 targeting the E gene of SARS-CoV-2, which produces the envelope small membrane protein. The gene was used as a target based on its similarity to previously identified coronavirus, including SARS-CoV strain Frankfurt and two Bat SARS-related CoV (GenBank Acc. No. MG772933.1 and NC_014470). The Primer-BLAST 18 tool was used to examine the specificity of the assay beyond what was described in the original publication. The search used default parameters and allowed 9 mismatches before ignoring the target sequence. The search returned hits from 957 SARS-CoV-2 isolate sequences and 7 pangolin coronavirus isolate sequences, indicating that it should be sensitive SARS-CoV-2 and only have the potential to cross-react on related non-human coronaviruses. The positive control consisted of ssDNA, targeting the E and N gene (below), in a 1:1 mixture at 10 3 copies/µL. ssDNA was based on the 2019-nCoV genome sequence published in Genbank 19 . *E gene target primers and probe: Target Sequence: 5′ACC AAA AGA TCA CAT TGG CAC CCG CAA TCC TGC TAA CAA TGC TGC AAT CGT GCT ACA ACT TCC TCA AGG AAC AAC ATT GCC AAA AGG CTT CTA CGC AGA AGG GAG CAG AGG CGG CAG TCA AGC CTC TTC TCG TTC CTC ATC ACG TAGT-3' Cell culture assays. Vero E6 cells were used to culture virus from environmental samples. The cells were cultured in Dulbeccos's minimal essential medium (DMEM) supplemented with heat inactivated fetal bovine serum (10%), Penicillin/Streptomycin (10,000 IU/mL & 10,000 µg/mL) and Amphotericin B (25 µg/mL). For propagation, 100 µl of undiluted samples were added to 24-well plates. The cells were monitored daily to detect virus-induced CPE. After 3-4 days cell supernatants and lysates were collected. For the time course PCR experiments, supernatant was collected on each day. Samples were evaluated for cytopathic effect. Immunofluorescence, performed using mouse monoclonal SARS-CoV to determine the presence of viral antigens. The reagent was obtained through BEI Resources, NIAID, NIH: Monoclonal Anti-SARS-CoV S Protein (Similar to 540C), NR-618. Cell nuclei were labeled with Hoechst 33342. Confocal images were collected with Ziess LSM 800 with Airyscan. For electron microscopy, samples were fixed, processed then sectioned and subsequently subjected to transmission electron microscopy (TEM). CPE images were acquired in the Nebraska Public Health Laboratory (NPHL) BSL3 facility using a 3D printed ocular adapter for cell phone photography, kindly donated by Dr. Jesse Cox, Yellow Basement Designs. Ethics approval. This study was conducted in the National Quarantine Unit and the Nebraska Biocontainment Unit with permission from the University of Nebraska Medical Center and Nebraska Medicine as a part of a quality assurance/quality improvement study on isolation care. Sampling of individual personal items was done with the owner's permission. Patients were informed that use of a face covering was not necessary during sampling activities, but the decision to wear or not wear provided surgical masks was left to the individual. This activity was reviewed by Office of Regulatory Affairs at the University of Nebraska Medical Center and it was determined that this project does not constitute human subject research as defined by 45CFR46.102. A novel coronavirus from patients with pneumonia in China Recognition of aerosol transmission of infectious agents: a commentary Detection of airborne severe acute respiratory syndrome (SARS) coronavirus and environmental contamination in SARS outbreak units A family cluster of Middle East respiratory syndrome coronavirus infections related to a likely unrecognized asymptomatic or mild case Droplet fate in indoor environments, or can we prevent the spread of infection in Indoor Air Transmission characteristics of MERS and SARS in the healthcare setting: a comparative study Environmental contamination and viral shedding in MERS patients during MERS-CoV outbreak in South Korea Clinical characteristics of 138 hospitalized patients with 2019 novel coronavirus-infected pneumonia in Wuhan, China Personal protective equipment processes and rationale for the Nebraska Biocontainment Unit during the 2014 activations for Ebola virus disease Diagnostic detection of Wuhan coronavirus 2019 by real-time RT-PCR. World Health Organization Air, surface environmental, and personal protective equipment contamination by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from a symptomatic patient Mathematical modeling of pathogen trajectory in a patient care environment Characterization of particulate emissions from occupant activities in offices Numerical investigation of influence of human walking on dispersion and deposition of expiratory droplets in airborne infection isolation room Modality of human expired aerosol size distributions Quantity, size distribution, and characteristics of cough generated aerosol produced by patients with an upper respiratory tract infection Aerosol and surface stability of HCoV-19 (SARS-CoV-2) compared to SARS-CoV-1. New Engl Primer-BLAST: A tool to design target-specific primers for polymerase chain reaction Wuhan seafood market pneumonia virus isolate Wuhan-Hu-1, complete genome All data is available in the main text or the supplementary materials.Received: 22 May 2020; Accepted: 9 July 2020 The authors would also like to thank all of the individuals in isolation and care at both the National Quarantine Unit and the Nebraska Biocontainment Unit for their willingness and interest in cooperating with this study. The authors would like to thank Tom Bargar and Nicholas Conoan of the Electron Microscopy Core Facility (EMCF) at the University of Nebraska Medical Center for technical assistance. The EMCF is supported by state funds from the Nebraska Research Initiative (NRI) and the University of Nebraska Foundation, and institutionally by the Office of the Vice Chancellor for Research. The authors would like to thank Janice A. Taylor and James Talaska of the Advanced Microscopy Core Facility at the University of Nebraska Medical Center for providing assistance with confocal microscopy. Funded by internal funds from the University of Nebraska Medical Center. The authors declare no competing interests. Supplementary information is available for this paper at https ://doi.org/10.1038/s4159 8-020-69286 -3.Correspondence and requests for materials should be addressed to J.L.S. Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creat iveco mmons .org/licen ses/by/4.0/.